SlideShare una empresa de Scribd logo
1 de 4
Descargar para leer sin conexión
Product Datasheet
Revised 6.11.13
Sikadur-42
Page 1 of 4
Construction Sikadur®
-42
High strength pourable epoxy resin grout
Description Sikadur-42 is a 3-component pourable or castable grout, based on a solvent
free epoxy resin and selected aggregates. Sikadur-42 cures to form a
hardened mortar with excellent adhesion to many substrates. This combined
with the product’s ease of application makes it ideally suited to site
application.
Uses As a grout for building and civil engineering application:
 Crane rails
 Machine bedding and baseplates
 Holding down bolts
 Stanchions
 Starter bars
 Cavity filling
 Bridge bearings
As a self smoothening mortar:
 Repairing and patching horizontal surfaces
Advantages  Insensitive to moisture during application, cure or whilst in service
 Applicable at low temperatures down to 5°C.
 Available in two grades (Normal and Long Potlife).
 High early strength
 Excellent adhesion to a wide variety of dry and damp substrates such as
concrete, stone, fibrous cement, synthetic resins, wood and most metals.
 High tensile and flexural strength, vibration resistant.
 Supplied in factory proportioned units
 Easily applied
 Unaffected by wide range of chemicals
 Good flow characteristics even in thin layers
 Proven in service over 30 years
Storage and Shelf Life Minimum shelf life is approximately 3 years. Store under controlled
conditions in original containers (minimum 5°C, maximum 35°C temperature
range).
Instructions for Use
Surface Preparation Mineral/Resin Substrates. Mechanically roughened, free from all
contaminants (eg. dust, oils, grease, ice, etc.), surface water, laitance, old
form oil, curing membrane and old coatings. Suitable methods of preparation
include blast cleaning and scabbling (sanding/grinding on fibrous cement). All
dirt must be removed from bolt by air blasting.
Wood. Mechanically cleaned, free from all contaminants (dust, oils, grease,
etc.) surface water, stains, impregnants and old coatings.
Iron/Steel. Mechanically cleaned, free from all contaminants (dust, oils,
grease, etc), coatings and corrosion products and surface water for maximum
bond strengths. Suitable methods include blast cleaning to minimum standard
SA2 AS 1627.9 or equivalent method to ST3 AS 1627.9.
Formwork The formwork used must be leak proof to allow for the free flowing Sikadur-
42. The formwork should be arranged so that the grout head is maintained
on the filling side above the level of the underside of the base plate. This will
allow gravity flow to completely fill the void to be grouted. Formwork should
be coated with form oil to allow easy removal of forms. Ensure adequate air
holes are provided.
Product Datasheet
Revised 6.11.13
Sikadur-42
Page 2 of 4
Construction Mixing Sikadur-42 is supplied in factory proportioned units comprising the correct
quantities of Part A (Resin), Part B (Hardender) and Part C (Aggregate).
Thoroughly stir Parts A and B separately using a slow running drill stirrer with
a spiral mixer (max. speed 250 rpm). Decant all of Part B into Part A and mix
thoroughly together until a uniform mix is achieved (typically 3 mins).
Continue to mix whilst adding Part C slowly. Ensure the attainment of an even
colour and an even distribution of aggregate throughout the mix. Do not
exceed 250 rpm. Allow to stand for 2-3 minutes to release any entrained air.
Application Mixed Sikadur-42 should be poured into the void or formwork from one side to
avoid the entrapment of air. Continuous grout flow is essential and there must
be sufficient grout available before pouring.
Machine Base Plates & Crane Rails: An adequate head must be
maintained to ensure continuous flow. Continue pouring until the grout rises
above the level of the plate. At no time during application should the grout
head be less than 75 mm above the level of the plate. This, as well as
adequate vent holes, is essential to ensure no air is trapped.
Anchor Bolts and Dowels: For bolts placed into preformed holes, fill the
hole with Sikadur-42 and place into the grout.
Thickness Generally, suitable thickness depends on clearance, distance of flow, ambient
and substrate temperatures and pour size. Maximum thickness in any one
pour (without aggregate addition) is 60mm.
Curing Being an epoxy, no special curing techniques are required. Curing time will
depend on the quantity and the ambient temperature. High volumes and high
temperatures result in short curing times. Maximum strength is usually
reached after 7 days. Do not install equipment or load the epoxy before full
cure.
Cleaning Uncured material may be cleaned from application tools, etc. by using Sika
Colma Cleaner (flammable solvent). Cured material can only be removed
mechanically.
Technical and Physical Data
Form Flowable mortar
Density 2.0 kg / litre approx.
Volume solids 100% (solvent free)
Mix ratio A : B : C = 2 : 1 : 14 by weight
Secant Flexural Modulus
of Elasticity (BS 6319)
15 GPa approx. @ 7 days
Compressive strength
@ 1 day 55 MPa approx.
@7 days 75 MPa approx.
Flexural strength @ 7 days
(BS 6319)
20 MPa approx.
Tensile strength @ 7 days
(BS 6319)
10 MPa approx.
Adhesion to concrete >4 MPa approx. @ 20°C (cohesive failure of concrete)
Adhesion to sand blasted
steel
>15 MPa approx. @ 20°C
Application Temperature
(min.-max.)
5°C – 30°C (Normal)
20°C-40°C (Long Potlife)
(substrate and ambient temperatures)
Product Datasheet
Revised 6.11.13
Sikadur-42
Page 3 of 4
Construction
Consumption/Coverage 2.0 kg/m² approx. per mm thickness (dependent on surface profile, texture,
temperature and wastage)
Colour Part A – Transparent (water white), Part B – Transparent (straw)
Part C – Grey/Sand
Grey when mixed
Packaging 14.6 Kg, 29.1Kg and 160Kg upon request.
Potlife (15kg mix) Temperature
20°C
35°C
Normal
65 mins
35 mins
Long Potlife
140 mins
65 mins
NOTE: Unless otherwise noted technical data applies to Normal Potlife (@20°C) and Long Potlife (@ 35°C)
Pull Out Characteristics
Indicative Pull Out Loads with Sikadur-42 and 40 MPa compressive strength concrete:
Rod Diameter (mm) 15 25 30
Hole diameter (mm) 22 37 45
Length (mm) 150 250 300
Pull out strength (kN) 27 55 137
Mode of failure Concrete Concrete Concrete
Product Datasheet
Revised 6.11.13
Sikadur-42
Page 4 of 4
Construction
Important Notes  For detailed information on grouting application and guidelines, refer to
Sika Grouting Systems Data Sheet.
 Do not apply Sikadur-42 to surfaces with standing water.
 Do not part mix containers.
 Only mix as much as can be applied within the stated potlife.
 Do not dilute the product with solvent as this will affect both the cure and
in-service performance.
 Constant in-service temperatures >70°C may affect the performance of
the product.
 Do not apply in large areas unless a damp proof membrane is in place.
 If applying in layers subsequent layers must be applied within 24 hours of
the first layer being applied and after the previous layer has cooled to
ambient temperature.
 If in doubt, consult our Technical Department.
 Minimum age of new concrete, 3 to 6 weeks.
 The temperature at which the Sikadur-42 is stored during the 24 hours
before it is mixed will govern it’s potlife when mixed.
 Sikadur-42 will rise in temperature when mixing. The extent of this
temperature rise will depend upon the volume to surface ratio and the
ambient and substrate temperature.
 Compressive strengths etc. of epoxy resins must be qualified by the
testing method eg. Test Standard or size of specimen under test and the
rate at which the test piece is loaded while under test, as these factors
will affect the result markedly. Faster loading rates will generally give
higher ultimate loads and vice versa. Also, a specimen at lower
temperature will show higher strengths and vice versa.
Handling Precautions  Avoid contact with the skin, eyes and avoid breathing it’s vapour.
 Wear protective gloves when mixing or using.
 If poisoning occurs, contact a doctor or Poisons Information Centre.
 If swallowed, do NOT induce vomiting. Give a glass of water.
 If skin contact occurs, remove contaminated clothing and wash skin
thoroughly.
 If in eyes, hold eyes open, flood with water for at least 15 minutes and
see a doctor.
 For more detailed information refer to our Material Safety Data Sheet.
Important Notification The information, and, in particular, the recommendations relating to the
application and end-use of Sika’s products, are given in good faith based on
Sika’s current knowledge and experience of the products when properly
stored, handled and applied under normal conditions. In practice, the
differences in materials, substrates and actual site conditions are such that no
warranty in respect of merchantability or of fitness for a particular purpose,
nor any liability arising out of any legal relationship whatsoever, can be
inferred either from this information, or from any written recommendations, or
from any other advice offered. The proprietary rights of third parties must be
observed. All orders are accepted subject of our terms and conditions of
sale. Users should always refer to the most recent issue of the Technical
Data Sheet for the product concerned, copies of which will be supplied on
request.
PLEASE CONSULT OUR TECHNICAL DEPARTMENT FOR FURTHER
INFORMATION.
Sika Australia Pty Limited www.sika.com.au
ABN 12 001 342 329 Tel: 1300 22 33 48

Más contenido relacionado

Similar a DUR-42 - PDS.pdf

Ultralit_catalog_2016_EN
Ultralit_catalog_2016_ENUltralit_catalog_2016_EN
Ultralit_catalog_2016_EN
Alexey Velikant
 
Supercap tds english
Supercap tds englishSupercap tds english
Supercap tds english
weebyx
 
Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011
Dhananjay Tekawade
 

Similar a DUR-42 - PDS.pdf (20)

Dx 5400 data sheet
Dx 5400 data sheetDx 5400 data sheet
Dx 5400 data sheet
 
Silvershield data sheet
Silvershield data sheetSilvershield data sheet
Silvershield data sheet
 
Method statement honycomb repairing
Method statement  honycomb repairingMethod statement  honycomb repairing
Method statement honycomb repairing
 
Ultralit_catalog_2016_EN
Ultralit_catalog_2016_ENUltralit_catalog_2016_EN
Ultralit_catalog_2016_EN
 
RIW Cementflex Datasheet
RIW Cementflex DatasheetRIW Cementflex Datasheet
RIW Cementflex Datasheet
 
Bonding solutions for assembly operations - Market brochure
Bonding solutions for assembly operations - Market brochureBonding solutions for assembly operations - Market brochure
Bonding solutions for assembly operations - Market brochure
 
QUEENTILE STONE COATED STEEL ROOFING
QUEENTILE STONE COATED STEEL ROOFING QUEENTILE STONE COATED STEEL ROOFING
QUEENTILE STONE COATED STEEL ROOFING
 
POLYGLASS ZIPCOAT
POLYGLASS ZIPCOATPOLYGLASS ZIPCOAT
POLYGLASS ZIPCOAT
 
Solutions for wind industry - Selector guide
Solutions for wind industry - Selector guideSolutions for wind industry - Selector guide
Solutions for wind industry - Selector guide
 
Molykote anti friction coatings selection guide
Molykote  anti friction coatings selection guideMolykote  anti friction coatings selection guide
Molykote anti friction coatings selection guide
 
Araldite Preparacion superficial y pretatamientos. Antala Industria (Spain).
Araldite Preparacion superficial y pretatamientos. Antala Industria (Spain).Araldite Preparacion superficial y pretatamientos. Antala Industria (Spain).
Araldite Preparacion superficial y pretatamientos. Antala Industria (Spain).
 
Araldite surface preparation and pretreatments. Antala Ltd.
Araldite surface preparation and pretreatments. Antala Ltd.Araldite surface preparation and pretreatments. Antala Ltd.
Araldite surface preparation and pretreatments. Antala Ltd.
 
IRJET - Effect of Silica Fume on Properties of Concrete
IRJET -  	  Effect of Silica Fume on Properties of ConcreteIRJET -  	  Effect of Silica Fume on Properties of Concrete
IRJET - Effect of Silica Fume on Properties of Concrete
 
Waterproofing of Terrace / Roof
Waterproofing of Terrace / RoofWaterproofing of Terrace / Roof
Waterproofing of Terrace / Roof
 
Plastifloor 1 8 inch flakes floor
Plastifloor 1 8 inch flakes floorPlastifloor 1 8 inch flakes floor
Plastifloor 1 8 inch flakes floor
 
Working with liquid applied waterproofing membrane
Working with liquid applied waterproofing membraneWorking with liquid applied waterproofing membrane
Working with liquid applied waterproofing membrane
 
Surface preparation and pretreatments - User guide
Surface preparation and pretreatments - User guideSurface preparation and pretreatments - User guide
Surface preparation and pretreatments - User guide
 
Supercap tds english
Supercap tds englishSupercap tds english
Supercap tds english
 
Tds barrier 80 - english (uk) - issued.05.10.2011
Tds   barrier 80 - english (uk) - issued.05.10.2011Tds   barrier 80 - english (uk) - issued.05.10.2011
Tds barrier 80 - english (uk) - issued.05.10.2011
 
RIW Flexiseal
RIW Flexiseal RIW Flexiseal
RIW Flexiseal
 

Último

"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
mphochane1998
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
ssuser89054b
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
9953056974 Low Rate Call Girls In Saket, Delhi NCR
 

Último (20)

Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best ServiceTamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
Tamil Call Girls Bhayandar WhatsApp +91-9930687706, Best Service
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
School management system project Report.pdf
School management system project Report.pdfSchool management system project Report.pdf
School management system project Report.pdf
 
kiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal loadkiln thermal load.pptx kiln tgermal load
kiln thermal load.pptx kiln tgermal load
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptxA CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
A CASE STUDY ON CERAMIC INDUSTRY OF BANGLADESH.pptx
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
data_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdfdata_management_and _data_science_cheat_sheet.pdf
data_management_and _data_science_cheat_sheet.pdf
 
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
Call Girls in South Ex (delhi) call me [🔝9953056974🔝] escort service 24X7
 
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
Bhubaneswar🌹Call Girls Bhubaneswar ❤Komal 9777949614 💟 Full Trusted CALL GIRL...
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptxHOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
HOA1&2 - Module 3 - PREHISTORCI ARCHITECTURE OF KERALA.pptx
 

DUR-42 - PDS.pdf

  • 1. Product Datasheet Revised 6.11.13 Sikadur-42 Page 1 of 4 Construction Sikadur® -42 High strength pourable epoxy resin grout Description Sikadur-42 is a 3-component pourable or castable grout, based on a solvent free epoxy resin and selected aggregates. Sikadur-42 cures to form a hardened mortar with excellent adhesion to many substrates. This combined with the product’s ease of application makes it ideally suited to site application. Uses As a grout for building and civil engineering application:  Crane rails  Machine bedding and baseplates  Holding down bolts  Stanchions  Starter bars  Cavity filling  Bridge bearings As a self smoothening mortar:  Repairing and patching horizontal surfaces Advantages  Insensitive to moisture during application, cure or whilst in service  Applicable at low temperatures down to 5°C.  Available in two grades (Normal and Long Potlife).  High early strength  Excellent adhesion to a wide variety of dry and damp substrates such as concrete, stone, fibrous cement, synthetic resins, wood and most metals.  High tensile and flexural strength, vibration resistant.  Supplied in factory proportioned units  Easily applied  Unaffected by wide range of chemicals  Good flow characteristics even in thin layers  Proven in service over 30 years Storage and Shelf Life Minimum shelf life is approximately 3 years. Store under controlled conditions in original containers (minimum 5°C, maximum 35°C temperature range). Instructions for Use Surface Preparation Mineral/Resin Substrates. Mechanically roughened, free from all contaminants (eg. dust, oils, grease, ice, etc.), surface water, laitance, old form oil, curing membrane and old coatings. Suitable methods of preparation include blast cleaning and scabbling (sanding/grinding on fibrous cement). All dirt must be removed from bolt by air blasting. Wood. Mechanically cleaned, free from all contaminants (dust, oils, grease, etc.) surface water, stains, impregnants and old coatings. Iron/Steel. Mechanically cleaned, free from all contaminants (dust, oils, grease, etc), coatings and corrosion products and surface water for maximum bond strengths. Suitable methods include blast cleaning to minimum standard SA2 AS 1627.9 or equivalent method to ST3 AS 1627.9. Formwork The formwork used must be leak proof to allow for the free flowing Sikadur- 42. The formwork should be arranged so that the grout head is maintained on the filling side above the level of the underside of the base plate. This will allow gravity flow to completely fill the void to be grouted. Formwork should be coated with form oil to allow easy removal of forms. Ensure adequate air holes are provided.
  • 2. Product Datasheet Revised 6.11.13 Sikadur-42 Page 2 of 4 Construction Mixing Sikadur-42 is supplied in factory proportioned units comprising the correct quantities of Part A (Resin), Part B (Hardender) and Part C (Aggregate). Thoroughly stir Parts A and B separately using a slow running drill stirrer with a spiral mixer (max. speed 250 rpm). Decant all of Part B into Part A and mix thoroughly together until a uniform mix is achieved (typically 3 mins). Continue to mix whilst adding Part C slowly. Ensure the attainment of an even colour and an even distribution of aggregate throughout the mix. Do not exceed 250 rpm. Allow to stand for 2-3 minutes to release any entrained air. Application Mixed Sikadur-42 should be poured into the void or formwork from one side to avoid the entrapment of air. Continuous grout flow is essential and there must be sufficient grout available before pouring. Machine Base Plates & Crane Rails: An adequate head must be maintained to ensure continuous flow. Continue pouring until the grout rises above the level of the plate. At no time during application should the grout head be less than 75 mm above the level of the plate. This, as well as adequate vent holes, is essential to ensure no air is trapped. Anchor Bolts and Dowels: For bolts placed into preformed holes, fill the hole with Sikadur-42 and place into the grout. Thickness Generally, suitable thickness depends on clearance, distance of flow, ambient and substrate temperatures and pour size. Maximum thickness in any one pour (without aggregate addition) is 60mm. Curing Being an epoxy, no special curing techniques are required. Curing time will depend on the quantity and the ambient temperature. High volumes and high temperatures result in short curing times. Maximum strength is usually reached after 7 days. Do not install equipment or load the epoxy before full cure. Cleaning Uncured material may be cleaned from application tools, etc. by using Sika Colma Cleaner (flammable solvent). Cured material can only be removed mechanically. Technical and Physical Data Form Flowable mortar Density 2.0 kg / litre approx. Volume solids 100% (solvent free) Mix ratio A : B : C = 2 : 1 : 14 by weight Secant Flexural Modulus of Elasticity (BS 6319) 15 GPa approx. @ 7 days Compressive strength @ 1 day 55 MPa approx. @7 days 75 MPa approx. Flexural strength @ 7 days (BS 6319) 20 MPa approx. Tensile strength @ 7 days (BS 6319) 10 MPa approx. Adhesion to concrete >4 MPa approx. @ 20°C (cohesive failure of concrete) Adhesion to sand blasted steel >15 MPa approx. @ 20°C Application Temperature (min.-max.) 5°C – 30°C (Normal) 20°C-40°C (Long Potlife) (substrate and ambient temperatures)
  • 3. Product Datasheet Revised 6.11.13 Sikadur-42 Page 3 of 4 Construction Consumption/Coverage 2.0 kg/m² approx. per mm thickness (dependent on surface profile, texture, temperature and wastage) Colour Part A – Transparent (water white), Part B – Transparent (straw) Part C – Grey/Sand Grey when mixed Packaging 14.6 Kg, 29.1Kg and 160Kg upon request. Potlife (15kg mix) Temperature 20°C 35°C Normal 65 mins 35 mins Long Potlife 140 mins 65 mins NOTE: Unless otherwise noted technical data applies to Normal Potlife (@20°C) and Long Potlife (@ 35°C) Pull Out Characteristics Indicative Pull Out Loads with Sikadur-42 and 40 MPa compressive strength concrete: Rod Diameter (mm) 15 25 30 Hole diameter (mm) 22 37 45 Length (mm) 150 250 300 Pull out strength (kN) 27 55 137 Mode of failure Concrete Concrete Concrete
  • 4. Product Datasheet Revised 6.11.13 Sikadur-42 Page 4 of 4 Construction Important Notes  For detailed information on grouting application and guidelines, refer to Sika Grouting Systems Data Sheet.  Do not apply Sikadur-42 to surfaces with standing water.  Do not part mix containers.  Only mix as much as can be applied within the stated potlife.  Do not dilute the product with solvent as this will affect both the cure and in-service performance.  Constant in-service temperatures >70°C may affect the performance of the product.  Do not apply in large areas unless a damp proof membrane is in place.  If applying in layers subsequent layers must be applied within 24 hours of the first layer being applied and after the previous layer has cooled to ambient temperature.  If in doubt, consult our Technical Department.  Minimum age of new concrete, 3 to 6 weeks.  The temperature at which the Sikadur-42 is stored during the 24 hours before it is mixed will govern it’s potlife when mixed.  Sikadur-42 will rise in temperature when mixing. The extent of this temperature rise will depend upon the volume to surface ratio and the ambient and substrate temperature.  Compressive strengths etc. of epoxy resins must be qualified by the testing method eg. Test Standard or size of specimen under test and the rate at which the test piece is loaded while under test, as these factors will affect the result markedly. Faster loading rates will generally give higher ultimate loads and vice versa. Also, a specimen at lower temperature will show higher strengths and vice versa. Handling Precautions  Avoid contact with the skin, eyes and avoid breathing it’s vapour.  Wear protective gloves when mixing or using.  If poisoning occurs, contact a doctor or Poisons Information Centre.  If swallowed, do NOT induce vomiting. Give a glass of water.  If skin contact occurs, remove contaminated clothing and wash skin thoroughly.  If in eyes, hold eyes open, flood with water for at least 15 minutes and see a doctor.  For more detailed information refer to our Material Safety Data Sheet. Important Notification The information, and, in particular, the recommendations relating to the application and end-use of Sika’s products, are given in good faith based on Sika’s current knowledge and experience of the products when properly stored, handled and applied under normal conditions. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The proprietary rights of third parties must be observed. All orders are accepted subject of our terms and conditions of sale. Users should always refer to the most recent issue of the Technical Data Sheet for the product concerned, copies of which will be supplied on request. PLEASE CONSULT OUR TECHNICAL DEPARTMENT FOR FURTHER INFORMATION. Sika Australia Pty Limited www.sika.com.au ABN 12 001 342 329 Tel: 1300 22 33 48