SlideShare una empresa de Scribd logo
1 de 36
1
Anhydrous Ammonia
Measurements
Roland Sirois
CONFIDENTIAL
2
Measurement Options
• Anhydrous Ammonia – oil & std water level
• Urea – oil
• DEF – oil
• UAN – oil
• Water – oil
• Air - oil
Technology applications in a wide range of products
3
Orono Spectral Solutions
• Spinoff of University of Maine (US) Laboratory
for Surface Science and Technology
• Awarded 14 government projects ($8.6 M)
• 2013 Tibbets Award & 2016 CF Safety Award
Leading edge solid state surface technology driven organization
4
Measuring oil in Ammonia
• CF Industries looking for solutions to
– Safely test oil contamination in ammonia
– Quickly identify process control issues
– Reduce corporate risk
Request from a leading ammonia manufacturer led to application
5
Materials Required to Measure
Glass ware, hot plate and dangerous chemicals
6
Oil Determination – Process
Evaporate Hexane
Mass corresponds to
concentration of
extractable material
Collect Large
Sample
Evaporate
Ammonia
Add
Hexane
Test Time: 8+ hours Tech Time: 3+ hours
Current method is long, complex, dangerous and costly
7
• Large sample size
• Safety risk: carrying sample through the plant
• Solvent (n-Hexane) & acid use
• Complex process
• Time consuming
• One “shot”
• Costly
Issues with the Current Process
Several factors with current method are driving development
8
New Process Equipment
No glassware, no chemicals, simple process
9
New Process Summary
Collect Small
Sample
Extract Sample Place in FTIR
Time: < 20 minutes
0
.1
.2
.3
.4
.5
.6
.7
3050 3000 2950 2900 2850 2800 2750
Absorbance / Wavenumber (cm-1) Paged X-Zoom CURSOR
File # 1 : BASELINE 11/5/2007 6:47 PM Res=8
disk 1 background after 10 ml ~30ppm oil in water
Absorbance(a.u.)
Wavenumber (cm-1)
Simple, quick, accurate and less costly process addesses SHE
10
FTIR Measurement
A =- log10 = e l c
l
C, e
Io I
I
Io
Where:
A = absorbance
e = absorptivity
l= pathlength
c = concentration
Infrared technology enables precise quantitative measurement
Membrane
11
Oil in Ammonia Output
Oil absorbance at 2920 and height relates to concentration
0
.1
.2
.3
.4
.5
.6
.7
3050 3000 2950 2900 2850 2800 2750
Absorbance(a.u.)
Wavenumber (cm-1)
12
• Sample 10 mls for each test - triplicate
• Place the extractor into the FTIR beam
• Program provides operator with a ppm oil level
• Permanent record of the results
Summary of New Process
Simple, accurate, safe and creates a permanent record
20 Min
13
Measurement of Known Amount
Spiking amount of mineral oil and measuring using technology
Method Performance Summary Data
Method Detection Limit 0.2 mg/L (ppm)
Detection Range 0.2 – 20 mg/L (ppm)
Precision at 3.5 mg/L 12%
14
Benefits of the New Process
Proven overwhelming advantages of new technology
• Complicated
• Fragile Glassware
• 500+ mL Ammonia (1 sample)
• Boiling Water, Hot Plate
• Hexane, Hydrochloric Acid
• 1-Day Turnaround Time
• 3 Hours for Lab Technician
• Hazardous Waste
• Chemistry
• Operating Cost
• Simple
• No Glassware
• 30 mL Ammonia (3 samples)
• No Heat Source Required
• No Additional Chemicals
• 20-Minute Turnaround Time
• 20 Minutes for Lab Technician
• Recyclable, Reusable Filters
• EPA Green Chemistry
• Operating Cost 25 – 30% less
Old Method New Method
15
• Reduce risk – safety, environmental
• Lower material on hold and rework potential
• Ability to ”dial in” water content
• Proven quality data and sample retention
Site Advantages
Financial impact of new technology is significant
16
• Use similar syringe and same sample size
• 10 mls of sample into extractor (10 sec)
• 10 mls of deionized water into extractor (20 sec)
• Drying of extractor
– Oven drying
– Air drying (dry air)
Oil in DEF and Urea
Process is similar to oil in ammonia but with drying required
17
• For transportation by truck, rail or pipe
– Minimum 0.2% water content (US Gov. requirement)
• Current process
– Time consuming
– Inaccurate
• Alternative process submitted to US DOT
– Once approval granted, companies can follow
process
• Commercial requirement 0.5% maximum
Water in Ammonia
In US process is regulated by US Department of Transportation (DOT)
18
• Small sample from manufacturing site
– Representative sample
– Protect sample from moisture
• Transfer to sampling container
– Protect sample from moisture
• Present the sample to the FTIR unit
– Protect sample from moisture
Water in Ammonia - Challenge
Protect sample from moisture in the air
19
Sampling for water in Ammonia
In process sample bottle to protect ammonia from moisture
• Pristine sample
• Protect technician
• Protect sample
20
Sample Carrier and Stand
Sample bottle stand and holder inside air hood
21
View of Sample Prep System
Maximize operator safety and sample integrity
• In lab system
• Ensures safety
• Uniform sample
22
Dry Air System
Portable air curtain supply kit to ensure sample integrity
23
Sample container for extraction
Transfer jar under dry air curtain
24
Details of Dry Air System
Positive dry air flow maintains curtain around sample
• Ammonia container
• Dry Air Container
• Dry Air Delivery
25
Water in Ammonia extractor
Extractor, FTIR Card and Hoses to provide dry air
• Extractor
• FTIR Card
• Dry air lines
26
Water in Ammonia extractor
Extractor, FTIR Card and Hoses to provide dry air
27
Accurate delivery of Ammonia
Small amount of sample required for test method
• Pipette
• Disposable tips
28
Sampling Ammonia
Using Pipette to sample exact amount for test
29
Ammonia sample on Extractor
Small sample will evaporate until extractor is dry
30
Inserting FTIR card into Unit
Place card into unit and run software
31
Test Method Detection Range
Measurement range is well within system capabilities
Method Data Summary
METHOD DETECTION LIMIT
(98% Confidence) MDL Detection Range
0.09% 0.2% - 0.5%
32
Customer Site Measurement
Accuracy of system demonstrated in test results
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.3% Water
Measured Result: % Water
REP 1 REP 2 REP 3 REP 4 REP 5 REP 6 REP 7 REP 8 REP 9 REP 10
0.32 0.27 0.28 0.34 0.36 0.30 0.31 0.33 0.28 0.35
Average of 10 Replicates: 0.3154 % Water
Standard Deviation of 10 Replicates: 0.032 % Water
MDL (Student’s t 2.821 x Standard Deviation) (98%Confidence): 0.09 % water
33
Accuracy of Method
Measurements at the low end of the test requirements
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.2% Water
Rep. Recovery (% water in AA)
Recovery as a % of known fortification amount
(0.2%)
1 0.2084 104.2%
2 0.1753 87.6%
3 0.2324 116.2%
4 0.2125 106.2%
5 0.2697 134.8%
6 0.2365 118.2%
7 0.2464 123.2%
Average 0.2259 112.9%
St. Dev. 0.0304
34
Accuracy of Method
Measurements at the high end of the test requirements
Method: Water in Anhydrous Ammonia
Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.5% Water
Rep. Recovery (% water in AA)
Recovery as a % of known fortification amount
(0.5%)
1 0.4574 91.5%
2 0.4923 98.4%
3 0.4475 89.5%
4 0.4843 96.8%
5 0.5191 103.8%
6 0.4744 94.9%
7 0.5401 108.0%
Average 0.4879 97.6%
St. Dev. 0.0329
35
Accuracy of Method
Water content of spiked samples over range 0 to 0.6%
36

Más contenido relacionado

La actualidad más candente

Qatargas debottlenecking project
Qatargas debottlenecking projectQatargas debottlenecking project
Qatargas debottlenecking project
John Kingsley
 

La actualidad más candente (20)

Buckmen Cooling Tower Chemistry
Buckmen Cooling Tower ChemistryBuckmen Cooling Tower Chemistry
Buckmen Cooling Tower Chemistry
 
Ammonia converter
Ammonia converterAmmonia converter
Ammonia converter
 
Ammonia production from natural gas, haldor topsoe process
Ammonia production from natural gas, haldor topsoe processAmmonia production from natural gas, haldor topsoe process
Ammonia production from natural gas, haldor topsoe process
 
Measuring Oil in Ammonia - OSS ClearShot Technology
Measuring Oil in Ammonia - OSS ClearShot TechnologyMeasuring Oil in Ammonia - OSS ClearShot Technology
Measuring Oil in Ammonia - OSS ClearShot Technology
 
GBH Enterprises Overview
GBH Enterprises OverviewGBH Enterprises Overview
GBH Enterprises Overview
 
Reactor and Catalyst Design
Reactor and Catalyst DesignReactor and Catalyst Design
Reactor and Catalyst Design
 
Reactor Modeling Tools - STANJAN
Reactor Modeling Tools - STANJANReactor Modeling Tools - STANJAN
Reactor Modeling Tools - STANJAN
 
Qatargas debottlenecking project
Qatargas debottlenecking projectQatargas debottlenecking project
Qatargas debottlenecking project
 
H - Acid Caustic Fusion Stage
H - Acid Caustic Fusion StageH - Acid Caustic Fusion Stage
H - Acid Caustic Fusion Stage
 
exp11 lab report
exp11 lab reportexp11 lab report
exp11 lab report
 
Hydrogen Plant - Normal Operations
Hydrogen Plant - Normal OperationsHydrogen Plant - Normal Operations
Hydrogen Plant - Normal Operations
 
Ethanol production line
Ethanol production lineEthanol production line
Ethanol production line
 
Heavy and fine chemicals
Heavy and fine chemicalsHeavy and fine chemicals
Heavy and fine chemicals
 
Cooling Water Treatment
Cooling Water TreatmentCooling Water Treatment
Cooling Water Treatment
 
Theory and Operation VSG-A101 Ammonia Synthesis Catalyst
Theory and Operation VSG-A101 Ammonia Synthesis CatalystTheory and Operation VSG-A101 Ammonia Synthesis Catalyst
Theory and Operation VSG-A101 Ammonia Synthesis Catalyst
 
Urea plant
Urea plantUrea plant
Urea plant
 
Secondary Reforming Flowsheets
Secondary Reforming FlowsheetsSecondary Reforming Flowsheets
Secondary Reforming Flowsheets
 
Theory and Operation of Methanation Catalyst
Theory and Operation of Methanation CatalystTheory and Operation of Methanation Catalyst
Theory and Operation of Methanation Catalyst
 
Phosphoric acid Industries
Phosphoric acid IndustriesPhosphoric acid Industries
Phosphoric acid Industries
 
Thermax Quality circle ppt
Thermax Quality circle pptThermax Quality circle ppt
Thermax Quality circle ppt
 

Similar a Anhydrous Ammonia Measurement for oil and water

Utilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water QualityUtilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water Quality
Muhammad Naeem Ashraf
 
PDA Poster Presentation - Particle Reduction_R01
PDA Poster Presentation - Particle Reduction_R01PDA Poster Presentation - Particle Reduction_R01
PDA Poster Presentation - Particle Reduction_R01
Aaron Mertens
 
Verifying Performance and Capability of New Technology for Surface and Subsur...
Verifying Performance and Capability of New Technology for Surface and Subsur...Verifying Performance and Capability of New Technology for Surface and Subsur...
Verifying Performance and Capability of New Technology for Surface and Subsur...
Society of Petroleum Engineers
 
Final Presentation
Final PresentationFinal Presentation
Final Presentation
Tyler Totten
 
Clean In Place Technlogies BioPharma Facilities
Clean In Place Technlogies BioPharma FacilitiesClean In Place Technlogies BioPharma Facilities
Clean In Place Technlogies BioPharma Facilities
Ranjeet Kumar
 
Sterile Facilities
Sterile FacilitiesSterile Facilities
Sterile Facilities
Eric Sipe
 
Leak Detection And Repair
Leak Detection And RepairLeak Detection And Repair
Leak Detection And Repair
Ashutosh Soni
 
Support utilities validation.pptx (asmita magare)
Support utilities validation.pptx (asmita magare)Support utilities validation.pptx (asmita magare)
Support utilities validation.pptx (asmita magare)
magareasmi
 

Similar a Anhydrous Ammonia Measurement for oil and water (20)

Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared SpectroscopyProcess Solutions from Wet Chemistry to Near-Infrared Spectroscopy
Process Solutions from Wet Chemistry to Near-Infrared Spectroscopy
 
GPO Application Dataset
GPO Application DatasetGPO Application Dataset
GPO Application Dataset
 
validation HPLC and HPTLC D-A star.pptx
validation HPLC and HPTLC D-A star.pptxvalidation HPLC and HPTLC D-A star.pptx
validation HPLC and HPTLC D-A star.pptx
 
Utilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water QualityUtilizing Online TOC Monitoring to Control Industrial Water Quality
Utilizing Online TOC Monitoring to Control Industrial Water Quality
 
Sterile process validation
Sterile process validationSterile process validation
Sterile process validation
 
GPO Customer Presentation
GPO Customer PresentationGPO Customer Presentation
GPO Customer Presentation
 
PDA Poster Presentation - Particle Reduction_R01
PDA Poster Presentation - Particle Reduction_R01PDA Poster Presentation - Particle Reduction_R01
PDA Poster Presentation - Particle Reduction_R01
 
Suncombe cip overview presentation
Suncombe cip overview presentationSuncombe cip overview presentation
Suncombe cip overview presentation
 
Oms
OmsOms
Oms
 
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...
5 Steps to Achieve More CostEffective Aminebased Carbon Capture Processes at ...
 
Validation of compressed air and nitrogen
Validation of compressed air and nitrogenValidation of compressed air and nitrogen
Validation of compressed air and nitrogen
 
Verifying Performance and Capability of New Technology for Surface and Subsur...
Verifying Performance and Capability of New Technology for Surface and Subsur...Verifying Performance and Capability of New Technology for Surface and Subsur...
Verifying Performance and Capability of New Technology for Surface and Subsur...
 
Final Presentation
Final PresentationFinal Presentation
Final Presentation
 
Clean In Place Technlogies BioPharma Facilities
Clean In Place Technlogies BioPharma FacilitiesClean In Place Technlogies BioPharma Facilities
Clean In Place Technlogies BioPharma Facilities
 
Sterile Facilities
Sterile FacilitiesSterile Facilities
Sterile Facilities
 
Le price training presentation
Le price training presentationLe price training presentation
Le price training presentation
 
Leak Detection And Repair
Leak Detection And RepairLeak Detection And Repair
Leak Detection And Repair
 
Group 4
Group 4Group 4
Group 4
 
Support utilities validation.pptx (asmita magare)
Support utilities validation.pptx (asmita magare)Support utilities validation.pptx (asmita magare)
Support utilities validation.pptx (asmita magare)
 
Plastic and Tire Pyrolysis Plant Manufacturers - Pyrocrat Systems LLP
Plastic and Tire Pyrolysis Plant Manufacturers - Pyrocrat Systems LLPPlastic and Tire Pyrolysis Plant Manufacturers - Pyrocrat Systems LLP
Plastic and Tire Pyrolysis Plant Manufacturers - Pyrocrat Systems LLP
 

Último

Corporate_Science-based_Target_Setting.pptx
Corporate_Science-based_Target_Setting.pptxCorporate_Science-based_Target_Setting.pptx
Corporate_Science-based_Target_Setting.pptx
arnab132
 
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
BrixsonLajara
 

Último (20)

Corporate_Science-based_Target_Setting.pptx
Corporate_Science-based_Target_Setting.pptxCorporate_Science-based_Target_Setting.pptx
Corporate_Science-based_Target_Setting.pptx
 
Call Girls in Shadnagar / 8250092165 Genuine Call girls with real Photos and ...
Call Girls in Shadnagar / 8250092165 Genuine Call girls with real Photos and ...Call Girls in Shadnagar / 8250092165 Genuine Call girls with real Photos and ...
Call Girls in Shadnagar / 8250092165 Genuine Call girls with real Photos and ...
 
Bhubaneswar Call Girl Service 📞9777949614📞Just Call Inaaya📲 Call Girls In Odi...
Bhubaneswar Call Girl Service 📞9777949614📞Just Call Inaaya📲 Call Girls In Odi...Bhubaneswar Call Girl Service 📞9777949614📞Just Call Inaaya📲 Call Girls In Odi...
Bhubaneswar Call Girl Service 📞9777949614📞Just Call Inaaya📲 Call Girls In Odi...
 
Introduction to heat waves and Heatwaves in Bangladesh.pptx
Introduction to heat waves and Heatwaves in Bangladesh.pptxIntroduction to heat waves and Heatwaves in Bangladesh.pptx
Introduction to heat waves and Heatwaves in Bangladesh.pptx
 
Call Girls Chikhali ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chikhali ( 8250092165 ) Cheap rates call girls | Get low budgetCall Girls Chikhali ( 8250092165 ) Cheap rates call girls | Get low budget
Call Girls Chikhali ( 8250092165 ) Cheap rates call girls | Get low budget
 
Call Girl Service in Wardha 9332606886 HOT & SEXY Models beautiful and charm...
Call Girl Service in Wardha  9332606886 HOT & SEXY Models beautiful and charm...Call Girl Service in Wardha  9332606886 HOT & SEXY Models beautiful and charm...
Call Girl Service in Wardha 9332606886 HOT & SEXY Models beautiful and charm...
 
Call Girls in Tiruppur 9332606886 ust Genuine Escort Model Sevice
Call Girls in Tiruppur  9332606886  ust Genuine Escort Model SeviceCall Girls in Tiruppur  9332606886  ust Genuine Escort Model Sevice
Call Girls in Tiruppur 9332606886 ust Genuine Escort Model Sevice
 
Fuel Cells and Hydrogen in Transportation - An Introduction
Fuel Cells and Hydrogen in Transportation - An IntroductionFuel Cells and Hydrogen in Transportation - An Introduction
Fuel Cells and Hydrogen in Transportation - An Introduction
 
Top Call Girls in Dholpur { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
Top Call Girls in Dholpur { 9332606886 } VVIP NISHA Call Girls Near 5 Star HotelTop Call Girls in Dholpur { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
Top Call Girls in Dholpur { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
 
A Review on Integrated River Basin Management and Development Master Plan of ...
A Review on Integrated River Basin Management and Development Master Plan of ...A Review on Integrated River Basin Management and Development Master Plan of ...
A Review on Integrated River Basin Management and Development Master Plan of ...
 
Yil Me Hu Spring 2024 - Nisqually Salmon Recovery Newsletter
Yil Me Hu Spring 2024 - Nisqually Salmon Recovery NewsletterYil Me Hu Spring 2024 - Nisqually Salmon Recovery Newsletter
Yil Me Hu Spring 2024 - Nisqually Salmon Recovery Newsletter
 
Sensual Call Girls in Surajpur { 9332606886 } VVIP NISHA Call Girls Near 5 St...
Sensual Call Girls in Surajpur { 9332606886 } VVIP NISHA Call Girls Near 5 St...Sensual Call Girls in Surajpur { 9332606886 } VVIP NISHA Call Girls Near 5 St...
Sensual Call Girls in Surajpur { 9332606886 } VVIP NISHA Call Girls Near 5 St...
 
Hertwich_EnvironmentalImpacts_BuildingsGRO.pptx
Hertwich_EnvironmentalImpacts_BuildingsGRO.pptxHertwich_EnvironmentalImpacts_BuildingsGRO.pptx
Hertwich_EnvironmentalImpacts_BuildingsGRO.pptx
 
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
Disaster risk reduction management Module 4: Preparedness, Prevention and Mit...
 
Deforestation
DeforestationDeforestation
Deforestation
 
Call Girls in Banswara { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
Call Girls in Banswara { 9332606886 } VVIP NISHA Call Girls Near 5 Star HotelCall Girls in Banswara { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
Call Girls in Banswara { 9332606886 } VVIP NISHA Call Girls Near 5 Star Hotel
 
Premium Call Girls Nashik Call Girls Service 👉📞 6378878445 👉📞 Just📲 Call Ruhi...
Premium Call Girls Nashik Call Girls Service 👉📞 6378878445 👉📞 Just📲 Call Ruhi...Premium Call Girls Nashik Call Girls Service 👉📞 6378878445 👉📞 Just📲 Call Ruhi...
Premium Call Girls Nashik Call Girls Service 👉📞 6378878445 👉📞 Just📲 Call Ruhi...
 
Call girl in Ajman 0503464457 Ajman Call girl services
Call girl in Ajman 0503464457 Ajman Call girl servicesCall girl in Ajman 0503464457 Ajman Call girl services
Call girl in Ajman 0503464457 Ajman Call girl services
 
Climate Change
Climate ChangeClimate Change
Climate Change
 
Russian Escort Dubai 0503464457 Dubai Escorts
Russian Escort Dubai 0503464457 Dubai EscortsRussian Escort Dubai 0503464457 Dubai Escorts
Russian Escort Dubai 0503464457 Dubai Escorts
 

Anhydrous Ammonia Measurement for oil and water

  • 2. 2 Measurement Options • Anhydrous Ammonia – oil & std water level • Urea – oil • DEF – oil • UAN – oil • Water – oil • Air - oil Technology applications in a wide range of products
  • 3. 3 Orono Spectral Solutions • Spinoff of University of Maine (US) Laboratory for Surface Science and Technology • Awarded 14 government projects ($8.6 M) • 2013 Tibbets Award & 2016 CF Safety Award Leading edge solid state surface technology driven organization
  • 4. 4 Measuring oil in Ammonia • CF Industries looking for solutions to – Safely test oil contamination in ammonia – Quickly identify process control issues – Reduce corporate risk Request from a leading ammonia manufacturer led to application
  • 5. 5 Materials Required to Measure Glass ware, hot plate and dangerous chemicals
  • 6. 6 Oil Determination – Process Evaporate Hexane Mass corresponds to concentration of extractable material Collect Large Sample Evaporate Ammonia Add Hexane Test Time: 8+ hours Tech Time: 3+ hours Current method is long, complex, dangerous and costly
  • 7. 7 • Large sample size • Safety risk: carrying sample through the plant • Solvent (n-Hexane) & acid use • Complex process • Time consuming • One “shot” • Costly Issues with the Current Process Several factors with current method are driving development
  • 8. 8 New Process Equipment No glassware, no chemicals, simple process
  • 9. 9 New Process Summary Collect Small Sample Extract Sample Place in FTIR Time: < 20 minutes 0 .1 .2 .3 .4 .5 .6 .7 3050 3000 2950 2900 2850 2800 2750 Absorbance / Wavenumber (cm-1) Paged X-Zoom CURSOR File # 1 : BASELINE 11/5/2007 6:47 PM Res=8 disk 1 background after 10 ml ~30ppm oil in water Absorbance(a.u.) Wavenumber (cm-1) Simple, quick, accurate and less costly process addesses SHE
  • 10. 10 FTIR Measurement A =- log10 = e l c l C, e Io I I Io Where: A = absorbance e = absorptivity l= pathlength c = concentration Infrared technology enables precise quantitative measurement Membrane
  • 11. 11 Oil in Ammonia Output Oil absorbance at 2920 and height relates to concentration 0 .1 .2 .3 .4 .5 .6 .7 3050 3000 2950 2900 2850 2800 2750 Absorbance(a.u.) Wavenumber (cm-1)
  • 12. 12 • Sample 10 mls for each test - triplicate • Place the extractor into the FTIR beam • Program provides operator with a ppm oil level • Permanent record of the results Summary of New Process Simple, accurate, safe and creates a permanent record 20 Min
  • 13. 13 Measurement of Known Amount Spiking amount of mineral oil and measuring using technology Method Performance Summary Data Method Detection Limit 0.2 mg/L (ppm) Detection Range 0.2 – 20 mg/L (ppm) Precision at 3.5 mg/L 12%
  • 14. 14 Benefits of the New Process Proven overwhelming advantages of new technology • Complicated • Fragile Glassware • 500+ mL Ammonia (1 sample) • Boiling Water, Hot Plate • Hexane, Hydrochloric Acid • 1-Day Turnaround Time • 3 Hours for Lab Technician • Hazardous Waste • Chemistry • Operating Cost • Simple • No Glassware • 30 mL Ammonia (3 samples) • No Heat Source Required • No Additional Chemicals • 20-Minute Turnaround Time • 20 Minutes for Lab Technician • Recyclable, Reusable Filters • EPA Green Chemistry • Operating Cost 25 – 30% less Old Method New Method
  • 15. 15 • Reduce risk – safety, environmental • Lower material on hold and rework potential • Ability to ”dial in” water content • Proven quality data and sample retention Site Advantages Financial impact of new technology is significant
  • 16. 16 • Use similar syringe and same sample size • 10 mls of sample into extractor (10 sec) • 10 mls of deionized water into extractor (20 sec) • Drying of extractor – Oven drying – Air drying (dry air) Oil in DEF and Urea Process is similar to oil in ammonia but with drying required
  • 17. 17 • For transportation by truck, rail or pipe – Minimum 0.2% water content (US Gov. requirement) • Current process – Time consuming – Inaccurate • Alternative process submitted to US DOT – Once approval granted, companies can follow process • Commercial requirement 0.5% maximum Water in Ammonia In US process is regulated by US Department of Transportation (DOT)
  • 18. 18 • Small sample from manufacturing site – Representative sample – Protect sample from moisture • Transfer to sampling container – Protect sample from moisture • Present the sample to the FTIR unit – Protect sample from moisture Water in Ammonia - Challenge Protect sample from moisture in the air
  • 19. 19 Sampling for water in Ammonia In process sample bottle to protect ammonia from moisture • Pristine sample • Protect technician • Protect sample
  • 20. 20 Sample Carrier and Stand Sample bottle stand and holder inside air hood
  • 21. 21 View of Sample Prep System Maximize operator safety and sample integrity • In lab system • Ensures safety • Uniform sample
  • 22. 22 Dry Air System Portable air curtain supply kit to ensure sample integrity
  • 23. 23 Sample container for extraction Transfer jar under dry air curtain
  • 24. 24 Details of Dry Air System Positive dry air flow maintains curtain around sample • Ammonia container • Dry Air Container • Dry Air Delivery
  • 25. 25 Water in Ammonia extractor Extractor, FTIR Card and Hoses to provide dry air • Extractor • FTIR Card • Dry air lines
  • 26. 26 Water in Ammonia extractor Extractor, FTIR Card and Hoses to provide dry air
  • 27. 27 Accurate delivery of Ammonia Small amount of sample required for test method • Pipette • Disposable tips
  • 28. 28 Sampling Ammonia Using Pipette to sample exact amount for test
  • 29. 29 Ammonia sample on Extractor Small sample will evaporate until extractor is dry
  • 30. 30 Inserting FTIR card into Unit Place card into unit and run software
  • 31. 31 Test Method Detection Range Measurement range is well within system capabilities Method Data Summary METHOD DETECTION LIMIT (98% Confidence) MDL Detection Range 0.09% 0.2% - 0.5%
  • 32. 32 Customer Site Measurement Accuracy of system demonstrated in test results Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.3% Water Measured Result: % Water REP 1 REP 2 REP 3 REP 4 REP 5 REP 6 REP 7 REP 8 REP 9 REP 10 0.32 0.27 0.28 0.34 0.36 0.30 0.31 0.33 0.28 0.35 Average of 10 Replicates: 0.3154 % Water Standard Deviation of 10 Replicates: 0.032 % Water MDL (Student’s t 2.821 x Standard Deviation) (98%Confidence): 0.09 % water
  • 33. 33 Accuracy of Method Measurements at the low end of the test requirements Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.2% Water Rep. Recovery (% water in AA) Recovery as a % of known fortification amount (0.2%) 1 0.2084 104.2% 2 0.1753 87.6% 3 0.2324 116.2% 4 0.2125 106.2% 5 0.2697 134.8% 6 0.2365 118.2% 7 0.2464 123.2% Average 0.2259 112.9% St. Dev. 0.0304
  • 34. 34 Accuracy of Method Measurements at the high end of the test requirements Method: Water in Anhydrous Ammonia Fortification Level of CGA G-2.2 Verified Dry Anhydrous Ammonia: 0.5% Water Rep. Recovery (% water in AA) Recovery as a % of known fortification amount (0.5%) 1 0.4574 91.5% 2 0.4923 98.4% 3 0.4475 89.5% 4 0.4843 96.8% 5 0.5191 103.8% 6 0.4744 94.9% 7 0.5401 108.0% Average 0.4879 97.6% St. Dev. 0.0329
  • 35. 35 Accuracy of Method Water content of spiked samples over range 0 to 0.6%
  • 36. 36