EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
IMPLICATIONS OF ACCURATE SOURCE CHARACTERIZATION
ON PERMITTING FOR THE 1-HR AND 24-HR NAAQS
Ron Petersen, PhD, CCM
CPP, Inc.
1415 Blue Spruce Drive
Fort Collins, CO 80525
rpetersen@cppwind.com
Cell: 970 690 1344
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Outline
• What is source characterization?
• The forgotten but important factor – building dimensions
• Where BPIP inputs are a problems
• Example applications of AERMOD with better inputs
(EBD)
• Impact of better inputs (i.e., accurate source
characterization)
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Source Characterization
2013 EPA Draft SO2 NAAQS Designations Modeling Technical
Assistance Document
Common considerations
• Stack height and location, stack parameters, emission
rates, in-stack ratios, urban versus rural, etc.
Often Overlooked (2 to 8 Reduction in Predicted
Design Value)
• “If stack locations and building information are
not accurate, downwash will not be
accurately accounted for in AERMOD.”
• Building dimension inputs are critical!!!
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Building Dimension Inputs & BPIP
 BPIP uses building footprints
and tier heights
 Combines buildings
 All structures become one
single rectangular solid for
each wind direction and
each source
 BPIP dimensions may not
characterize the source and
may give the wrong answer.
BPIP Input
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
AERMOD’s Building Downwash Algorithm
• Used EPA wind
tunnel data base and
past literature
• Developed analytical
equations for cavity
height, reattachment,
streamline angle,
wind speed and
turbulence
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
AERMOD’s Building Downwash Algorithm
Only valid for certain
building sizes
• W/H 1 to 4
• L/H = 0 to 4
• Assumes all
buildings are solid
and rectangular
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Building Dimension Inputs AERMOD Needs to
Work
The building shape
and position that
match the theory in
AERMOD.
BPIP will often not
do this.
Streamline figures from: Snyder, W.H. and R.E. Lawson, Jr.: Wind Tunnel Measurements of Flow Fields in the Vicinity
of Buildings; 8th Joint Conference on Appl. of Air Poll. Met. With A&WMA; AMS, Boston, MA, 1994; pp. 244-250
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
• Example BPIP Problems
PW facility (blue), BPIP building dimensions (red) for stack S-344 (red) and
envelope of the building cavity calculated by PRIME (yellow) for a) a wind
direction of 90 degrees; and b) a wind direction of 140 degrees.
)
BPIP Building Dimensions:
H = 17 m
L/H = 53
W/H = 34
BPIP Building Dimensions:
H = 17 m
L/H = 23
W/H = 63
a)
b)
BPIP Building Dimensions:
H = 17 m
L/H = 23
W/H = 63
BPIP Input in RED
Site Plan and BPIP Result
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Solution - Use EBD in Place of BPIP Dimensions
• Equivalent Building Dimensions” (EBDs) are the
dimensions that are input into AERMOD in place of BPIP
dimensions to more accurately predict building wake
effects
• Determined using wind tunnel modeling
9
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Current Regulatory Status of EBD
October 24, 2011 Model Clearinghouse Review of EBD for AERMOD
• “.. any EBD studies being considered should be
discussed with the appropriate reviewing authority as
early in the process as possible and that the Model
Clearinghouse should also be engaged as early as
possible.”
• …. these wind tunnel EBD studies are classified
as “source characterization studies.”
• Roger Brode and George Bridgers, EPA Model
Clearinghouse, receptive for those cases where
AERMOD with BPIP inputs is not working – 2013 EPA
R/S/L Modelers Workshop.
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Basic Wind Tunnel Modeling Methodology
•Obtain source/site data
•Construct scale model
– 3D Printing
•Install model in wind
tunnel and measure
Cmax versus X
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Measure Ground-level Concentrations
Tracer
from stack
Max ground-level concentrations measured versus x
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Measure Ground-level Concentrations
Data taken until good fit and max
obtained
Automated Max GL Concentration Mapper
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
EBD Used to Reduce Predicted AQ Impacts on Residential
Tower downwind of Mirant Power Station, Alexandria, VA
Residential Tower
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Find EBD that gives same Max GL Concentration
Profile as with Site Structures
=
- Input EBD Into AERMOD for wind directions of concern
- AERMOD predicted impacts decreased by more than a
factor of two.
Mirant Power Station – Approved Study, Region 3
Wind Tunnel Testing Conducted with Site Structures and
with EBD
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
AECOM (David Shea) Conducted Field Study That
Validated use of EBD – see AWMA 2007 papers
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Example Application
Very wide/narrow building
Stack height: 47 m
Building height: 31 m
Property line in Red
Emission rate: 1 g/s
AERMOD RESULTS
Five years of met data
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Maximum Hourly Impact at Fenceline
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
BPIP Input Analysis
• W and L values > 5 times Hb for
many wind directions (see red
shading)
• AERMOD will overpredict for these
wind directions
• Past EBD studies and theory show
that Lmax and Wmax ≤ 4 Hb.
• New BPIP input generated using this
criterion
• Input filed provided to modeling
consultant to re-run AERMOD
Flow Wind BUILDHGT BUILDWID BUILDLEN
Vector Direction Hb W L XBADJ YBADJ Hb: W: L
(Deg.) (Deg.) (m) (m) (m) (m) (m)
0 180 31.09 88.64 304.03 -144.87 -58.28 1.0 2.9 9.8
10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5
20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5
30 210 31.09 98.96 301.7 -115.52 -46.9 1.0 3.2 9.7
40 220 31.09 148.5 284.64 -99.38 -40.06 1.0 4.8 9.2
50 230 31.09 193.52 258.94 -80.23 -31.99 1.0 6.2 8.3
60 240 31.09 232.67 225.36 -58.63 -22.96 1.0 7.5 7.2
70 250 31.09 264.74 184.94 -35.26 -13.22 1.0 8.5 5.9
80 260 31.09 288.77 138.9 -10.81 -3.08 1.0 9.3 4.5
90 270 31.09 304.03 88.64 13.97 7.14 1.0 9.8 2.9
100 280 31.09 310.04 35.68 38.32 17.16 1.0 10.0 1.1
110 290 31.09 309.59 46.42 29.12 26.65 1.0 10.0 1.5
120 300 31.09 301.7 98.96 -2.58 35.33 1.0 9.7 3.2
130 310 31.09 284.64 148.5 -34.19 42.94 1.0 9.2 4.8
140 320 31.09 258.94 193.52 -64.77 49.24 1.0 8.3 6.2
150 330 31.09 225.36 232.67 -93.38 54.05 1.0 7.2 7.5
160 340 31.09 184.94 264.74 -119.15 57.21 1.0 5.9 8.5
170 350 31.09 138.9 288.77 -141.3 58.64 1.0 4.5 9.3
180 360 31.09 88.64 304.03 -159.16 58.28 1.0 2.9 9.8
190 10 24.99 30.53 11.47 -3.68 18.85 1.0 1.2 0.5
200 20 24.99 30.76 12.48 -7.49 18.91 1.0 1.2 0.5
210 30 31.09 98.96 301.7 -186.18 46.9 1.0 3.2 9.7
220 40 31.09 148.5 284.64 -185.26 40.06 1.0 4.8 9.2
230 50 31.09 193.52 258.94 -178.71 31.99 1.0 6.2 8.3
240 60 31.09 232.67 225.36 -166.73 22.95 1.0 7.5 7.2
250 70 31.09 264.74 184.94 -149.68 13.22 1.0 8.5 5.9
260 80 31.09 288.77 138.9 -128.09 3.08 1.0 9.3 4.5
270 90 31.09 304.03 88.64 -102.6 -7.14 1.0 9.8 2.9
280 100 31.09 310.04 35.68 -74 -17.16 1.0 10.0 1.1
290 110 31.09 309.59 46.42 -75.54 -26.65 1.0 10.0 1.5
300 120 31.09 301.7 98.96 -96.39 -35.33 1.0 9.7 3.2
310 130 31.09 284.64 148.5 -114.31 -42.94 1.0 9.2 4.8
320 140 31.09 258.94 193.52 -128.75 -49.24 1.0 8.3 6.2
330 150 31.09 225.36 232.67 -139.29 -54.05 1.0 7.2 7.5
340 160 31.09 184.94 264.74 -145.59 -57.21 1.0 5.9 8.5
350 170 31.09 138.9 288.77 -147.47 -58.64 1.0 4.5 9.3
BPIP Dimensions
Aspect Ratio
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
BPIP Input Analysis – Zoom In
Flow Wind BUILDHGT BUILDWID BUILDLEN
Vector Direction Hb W L XBADJ YBADJ Hb: W: L
(Deg.) (Deg.) (m) (m) (m) (m) (m)
0 180 31.09 88.64 304.03 -144.87 -58.28 1.0 2.9 9.8
10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5
20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5
30 210 31.09 98.96 301.7 -115.52 -46.9 1.0 3.2 9.7
40 220 31.09 148.5 284.64 -99.38 -40.06 1.0 4.8 9.2
50 230 31.09 193.52 258.94 -80.23 -31.99 1.0 6.2 8.3
60 240 31.09 232.67 225.36 -58.63 -22.96 1.0 7.5 7.2
70 250 31.09 264.74 184.94 -35.26 -13.22 1.0 8.5 5.9
80 260 31.09 288.77 138.9 -10.81 -3.08 1.0 9.3 4.5
90 270 31.09 304.03 88.64 13.97 7.14 1.0 9.8 2.9
100 280 31.09 310.04 35.68 38.32 17.16 1.0 10.0 1.1
110 290 31.09 309.59 46.42 29.12 26.65 1.0 10.0 1.5
120 300 31.09 301.7 98.96 -2.58 35.33 1.0 9.7 3.2
BPIP Dimensions
Aspect Ratio
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Estimated EBD values
• Estimated values to right used to
modify AERMOD input file
• AERMOD re-run with these
building dimension inputs
• AERMOD results below show
wind tunnel study likely to help
significantly
AERMOD Building Dimension
Inputs 1-hour 24-hour annual
BPIP 15.19 8.20 0.89
Screening EBD Values 9.68 5.05 0.19
AERMOD Maximum predicted
concentration (μg/m3
)
Flow Wind BUILDHGT BUILDWID BUILDLEN
Vector Direction Hb W L XBADJ YBADJ Hb: W: L
(Deg.) (Deg.) (m) (m) (m) (m) (m)
0 180 31.09 88.64 124.36 -144.87 -58.28 1.0 2.9 4.0
10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5
20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5
30 210 31.09 98.96 124.36 -115.52 -46.9 1.0 3.2 4.0
40 220 31.09 124.36 124.36 -99.38 -40.06 1.0 4.0 4.0
50 230 31.09 124.36 124.36 -80.23 -31.99 1.0 4.0 4.0
60 240 31.09 124.36 124.36 -58.63 -22.96 1.0 4.0 4.0
70 250 31.09 124.36 124.36 -35.26 -13.22 1.0 4.0 4.0
80 260 31.09 124.36 124.36 -10.81 -3.08 1.0 4.0 4.0
90 270 31.09 124.36 88.64 13.97 7.14 1.0 4.0 2.9
100 280 31.09 124.36 35.68 38.32 17.16 1.0 4.0 1.1
110 290 31.09 124.36 46.42 29.12 26.65 1.0 4.0 1.5
120 300 31.09 124.36 98.96 -2.58 35.33 1.0 4.0 3.2
130 310 31.09 124.36 124.36 -34.19 42.94 1.0 4.0 4.0
140 320 31.09 124.36 124.36 -64.77 49.24 1.0 4.0 4.0
150 330 31.09 124.36 124.36 -93.38 54.05 1.0 4.0 4.0
160 340 31.09 124.36 124.36 -119.15 57.21 1.0 4.0 4.0
170 350 31.09 124.36 124.36 -141.3 58.64 1.0 4.0 4.0
180 360 31.09 88.64 124.36 -159.16 58.28 1.0 2.9 4.0
190 10 24.99 30.53 11.47 -3.68 18.85 1.0 1.2 0.5
200 20 24.99 30.76 12.48 -7.49 18.91 1.0 1.2 0.5
210 30 31.09 98.96 124.36 -186.18 46.9 1.0 3.2 4.0
220 40 31.09 124.36 124.36 -185.26 40.06 1.0 4.0 4.0
230 50 31.09 124.36 124.36 -178.71 31.99 1.0 4.0 4.0
240 60 31.09 124.36 124.36 -166.73 22.95 1.0 4.0 4.0
250 70 31.09 124.36 124.36 -149.68 13.22 1.0 4.0 4.0
260 80 31.09 124.36 124.36 -128.09 3.08 1.0 4.0 4.0
270 90 31.09 124.36 88.64 -102.6 -7.14 1.0 4.0 2.9
280 100 31.09 124.36 35.68 -74 -17.16 1.0 4.0 1.1
290 110 31.09 124.36 46.42 -75.54 -26.65 1.0 4.0 1.5
300 120 31.09 124.36 98.96 -96.39 -35.33 1.0 4.0 3.2
310 130 31.09 124.36 124.36 -114.31 -42.94 1.0 4.0 4.0
320 140 31.09 124.36 124.36 -128.75 -49.24 1.0 4.0 4.0
330 150 31.09 124.36 124.36 -139.29 -54.05 1.0 4.0 4.0
340 160 31.09 124.36 124.36 -145.59 -57.21 1.0 4.0 4.0
350 170 31.09 124.36 124.36 -147.47 -58.64 1.0 4.0 4.0
Estimated EBD using Max Width and Length Criteria of 4 times the Height
Aspect Ratio
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
AERMOD Results With Wind Tunnel EBD
Very wide/narrow building
Stack height: 47 m
Building height: 31 m
Property line in Red
Emission rate: 1 g/s
AERMOD RESULTS
Five years of met data
AERMOD Building Dimension
Inputs 1-hour 24-hour annual
BPIP 15.19 8.20 0.89
Wind Tunnel EBD 3.99 1.88 0.18
Reduction Factor 3.80 4.37 4.93
AERMOD Maximum predicted
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Stack at Industrial Facility
Stack height = 27 m
Q = 1 g/s
Building height = 17 m
Building width and/or length > 200 m
5 years of meteorological data
AERMOD RESULTS
SHORT LARGE BUILDING
Building Input 1-hr 3-hr 24-hr annual
BPIP 129.1 101.7 38.2 4.0
Wind Tunnel EBD 27.3 17.8 7.9 0.5
Reduction Factor 4.7 5.7 4.8 7.9
Maximum concentration (ug/m3
)
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
BPIP
Max = 38.2 ug/m3
EBD
Max = 8.1ug/m3
AERMOD Contours: 24-hr max
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Stack height: 45 m
Structure height: 61 m
Emission rate: 1 g/s
Five years of met data
Stack
AERMOD Results
Lattice Structure
Building
Input 1-hour 24-hour annual
BPIP 23.21 5.51 0.37
Wind Tunnel EBD 7.72 2.36 0.11
Reduction Factor 3.01 2.33 3.51
Maximum Concentration Results
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
FACTOR of 4 to 8
reduction when EBD used
Short building with a large foot print
FACTOR of 2 to 4
reduction when EBD used
Hyperbolic cooling towers
Typical AERMOD Overprediction
Factors When Using BPIP Inputs
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Typical AERMOD Overprediction
Factors When Using BPIP Inputs
FACTOR of 2 to 5
reduction when EBD used
Very Wide/Narrow Buildings
FACTOR of 2 to 3.5
reduction when EBD used
Lattice Structures
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Result of Accurate Building Dimension
Source Characterization
• More accurate
concentration
estimates
• Estimates that are 2
to 8 times lower for
appropriate cases
Short/wide/long
Streamlined
Wide
Lattice
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
Questions?
Ron Petersen, Ph.D., CCM
CPP, Inc
rpetersen@cppwind.com
970 690 1344
EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants
EBD Background
• Several studies conducted and approved using original guidance for
ISC applications
• Amoco Whiting Refinery, Region 5, 1990
• Public Service Electric & Gas, Region 2, 1993
• Cape Industries, Region 4, 1993
• Cambridge Electric Plant, Region 1, 1993
• District Energy, Region 5, 1993
• Hoechst Celanese Celco Plant, Region 3, 1994
• Pleasants Power, Region 3, 2002
• Studies conducted using AERMOD
• Hawaiian Electric (Approved), Region 9, 1998
• Mirant Power Station (Approved), Region 3, 2006
• Cheswick Power Plant (Approved), Region 3, 2006
• Alcoa (Not Approved), Region 7, 2010
• Chevron (Approved), Region 4, 2012

Más contenido relacionado

La actualidad más candente

PRIME2: Model Evaluations
PRIME2: Model EvaluationsPRIME2: Model Evaluations
PRIME2: Model Evaluations
Sergio A. Guerra
 
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
Sergio A. Guerra
 
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
Sergio A. Guerra
 
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
NYCCTfab
 
PRIME2 Model Evaluation
PRIME2 Model EvaluationPRIME2 Model Evaluation
PRIME2 Model Evaluation
Sergio A. Guerra
 
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONSEFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
Sergio A. Guerra
 
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
Sergio A. Guerra
 
Use of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
Use of Probabilistic Statistical Techniques in AERMOD Modeling EvaluationsUse of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
Use of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
Sergio A. Guerra
 

La actualidad más candente (20)

PRIME2: Model Evaluations
PRIME2: Model EvaluationsPRIME2: Model Evaluations
PRIME2: Model Evaluations
 
Evaluation of the Theoretical Problems with Building Downwash Using A New Met...
Evaluation of the Theoretical Problems with Building Downwash Using A New Met...Evaluation of the Theoretical Problems with Building Downwash Using A New Met...
Evaluation of the Theoretical Problems with Building Downwash Using A New Met...
 
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
Use of Wind Tunnel Refinements in the Dispersion Modeling Analysis of the Ala...
 
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
NOVEL DATA ANALYSIS TECHNIQUE USED TO EVALUATE NOX AND CO2 CONTINUOUS EMISSIO...
 
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
Closing the LOOP - Int'l High Performance Building Conference (Lansing Commun...
 
Pressure Coefficients on Building Facades for Building Simulation
Pressure Coefficients on Building Facades for Building SimulationPressure Coefficients on Building Facades for Building Simulation
Pressure Coefficients on Building Facades for Building Simulation
 
Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs) Cathodic Protection for Above Ground Storage Tanks (AGSTs)
Cathodic Protection for Above Ground Storage Tanks (AGSTs)
 
PRIME2: Consequence Analysis and Model Evaluation
PRIME2: Consequence Analysis and Model EvaluationPRIME2: Consequence Analysis and Model Evaluation
PRIME2: Consequence Analysis and Model Evaluation
 
Using Physical Modeling to Refine Downwash Inputs to AERMOD
Using Physical Modeling to Refine Downwash Inputs to AERMODUsing Physical Modeling to Refine Downwash Inputs to AERMOD
Using Physical Modeling to Refine Downwash Inputs to AERMOD
 
PRIME2 Model Evaluation
PRIME2 Model EvaluationPRIME2 Model Evaluation
PRIME2 Model Evaluation
 
Advanced Modeling Techniques for Permit Modeling - Turning challenges into o...
Advanced Modeling Techniques for Permit Modeling - Turning challenges into o...Advanced Modeling Techniques for Permit Modeling - Turning challenges into o...
Advanced Modeling Techniques for Permit Modeling - Turning challenges into o...
 
APM Subcommmittee Update on PRIME2 Research Study
APM Subcommmittee Update on PRIME2 Research StudyAPM Subcommmittee Update on PRIME2 Research Study
APM Subcommmittee Update on PRIME2 Research Study
 
EVALUATION OF SO2 AND NOX OFFSET RATIOS TO ACCOUNT FOR SECONDARY PM2.5 FORMATION
EVALUATION OF SO2 AND NOX OFFSET RATIOS TO ACCOUNT FOR SECONDARY PM2.5 FORMATIONEVALUATION OF SO2 AND NOX OFFSET RATIOS TO ACCOUNT FOR SECONDARY PM2.5 FORMATION
EVALUATION OF SO2 AND NOX OFFSET RATIOS TO ACCOUNT FOR SECONDARY PM2.5 FORMATION
 
AI&C Facility Underground Piping Program
AI&C Facility Underground Piping ProgramAI&C Facility Underground Piping Program
AI&C Facility Underground Piping Program
 
Pairing aermod concentrations with the 50th percentile monitored value
Pairing aermod concentrations with the 50th percentile monitored valuePairing aermod concentrations with the 50th percentile monitored value
Pairing aermod concentrations with the 50th percentile monitored value
 
INNOVATIVE DISPERSION MODELING PRACTICES TO ACHIEVE A REASONABLE LEVEL OF CON...
INNOVATIVE DISPERSION MODELING PRACTICES TO ACHIEVE A REASONABLE LEVEL OF CON...INNOVATIVE DISPERSION MODELING PRACTICES TO ACHIEVE A REASONABLE LEVEL OF CON...
INNOVATIVE DISPERSION MODELING PRACTICES TO ACHIEVE A REASONABLE LEVEL OF CON...
 
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONSEFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
EFFECTS OF MET DATA PROCESSING IN AERMOD CONCENTRATIONS
 
Optimization of performance and emission characteristics of dual flow diesel ...
Optimization of performance and emission characteristics of dual flow diesel ...Optimization of performance and emission characteristics of dual flow diesel ...
Optimization of performance and emission characteristics of dual flow diesel ...
 
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
Solution to AERMOD/PRIME PM10 Overpredictions for Extremely Short, Long and W...
 
Use of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
Use of Probabilistic Statistical Techniques in AERMOD Modeling EvaluationsUse of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
Use of Probabilistic Statistical Techniques in AERMOD Modeling Evaluations
 

Destacado

ΚΙΤΟU ANNA CV-EN
ΚΙΤΟU ANNA CV-ENΚΙΤΟU ANNA CV-EN
ΚΙΤΟU ANNA CV-EN
ANNA KITOU
 
โครงงานคอมพิวเตอร์
โครงงานคอมพิวเตอร์โครงงานคอมพิวเตอร์
โครงงานคอมพิวเตอร์
Mark'k Stk
 
Safeguarding in Maternity Services
Safeguarding  in Maternity ServicesSafeguarding  in Maternity Services
Safeguarding in Maternity Services
LGTNHS
 
Httpool fashion week2015
Httpool fashion week2015Httpool fashion week2015
Httpool fashion week2015
fashiontechcz
 
David Draper Resume 2
David Draper Resume 2David Draper Resume 2
David Draper Resume 2
David Draper
 
3 size id-fashiontechcz
3 size id-fashiontechcz3 size id-fashiontechcz
3 size id-fashiontechcz
fashiontechcz
 

Destacado (19)

ΚΙΤΟU ANNA CV-EN
ΚΙΤΟU ANNA CV-ENΚΙΤΟU ANNA CV-EN
ΚΙΤΟU ANNA CV-EN
 
Training Certificates
Training CertificatesTraining Certificates
Training Certificates
 
MovePlan_Brochure
MovePlan_BrochureMovePlan_Brochure
MovePlan_Brochure
 
โครงงานคอมพิวเตอร์
โครงงานคอมพิวเตอร์โครงงานคอมพิวเตอร์
โครงงานคอมพิวเตอร์
 
Blair John Stevens
Blair John Stevens Blair John Stevens
Blair John Stevens
 
Safeguarding in Maternity Services
Safeguarding  in Maternity ServicesSafeguarding  in Maternity Services
Safeguarding in Maternity Services
 
Resume Updated 3
Resume Updated 3Resume Updated 3
Resume Updated 3
 
RESUME UPDATED 2015
RESUME UPDATED 2015RESUME UPDATED 2015
RESUME UPDATED 2015
 
Praluent abstract.
Praluent abstract.Praluent abstract.
Praluent abstract.
 
Colmos
Colmos Colmos
Colmos
 
The Interactive Education Story
The Interactive Education StoryThe Interactive Education Story
The Interactive Education Story
 
Research publication
Research publicationResearch publication
Research publication
 
Httpool fashion week2015
Httpool fashion week2015Httpool fashion week2015
Httpool fashion week2015
 
Avrora boat
Avrora boatAvrora boat
Avrora boat
 
David Draper Resume 2
David Draper Resume 2David Draper Resume 2
David Draper Resume 2
 
3 size id-fashiontechcz
3 size id-fashiontechcz3 size id-fashiontechcz
3 size id-fashiontechcz
 
Xylitol 87-99-0-api
Xylitol 87-99-0-apiXylitol 87-99-0-api
Xylitol 87-99-0-api
 
openMDM5: From a fat client to a scalable, omni-channel architecture
openMDM5: From a fat client to a scalable, omni-channel architectureopenMDM5: From a fat client to a scalable, omni-channel architecture
openMDM5: From a fat client to a scalable, omni-channel architecture
 
Gamify Your Fundraiser
Gamify Your Fundraiser Gamify Your Fundraiser
Gamify Your Fundraiser
 

Similar a IMPLICATIONS OF ACCURATE SOURCE CHARACTERIZATION ON PERMITTING FOR THE 1-HOUR NAAQS

Presentation2_Agus Widyianto_MSME.pdf
Presentation2_Agus Widyianto_MSME.pdfPresentation2_Agus Widyianto_MSME.pdf
Presentation2_Agus Widyianto_MSME.pdf
AgusWidyianto2
 
Probabilistic & Source Characterization Techniques in AERMOD Compliance
Probabilistic & Source Characterization Techniques in AERMOD ComplianceProbabilistic & Source Characterization Techniques in AERMOD Compliance
Probabilistic & Source Characterization Techniques in AERMOD Compliance
Sergio A. Guerra
 
Billet Surface Quality Improvement
Billet Surface Quality ImprovementBillet Surface Quality Improvement
Billet Surface Quality Improvement
DeanMardilan
 
Prefeseability study of petroleum field
Prefeseability study of petroleum fieldPrefeseability study of petroleum field
Prefeseability study of petroleum field
Safwen Sakhraoui
 

Similar a IMPLICATIONS OF ACCURATE SOURCE CHARACTERIZATION ON PERMITTING FOR THE 1-HOUR NAAQS (20)

Building Performance Modeling: How to Use Modeling Analysis to Optimize Desig...
Building Performance Modeling: How to Use Modeling Analysis to Optimize Desig...Building Performance Modeling: How to Use Modeling Analysis to Optimize Desig...
Building Performance Modeling: How to Use Modeling Analysis to Optimize Desig...
 
SCS Global Certification of CTC Global ACCC Conductor
SCS Global Certification of CTC Global ACCC ConductorSCS Global Certification of CTC Global ACCC Conductor
SCS Global Certification of CTC Global ACCC Conductor
 
Presentation2_Agus Widyianto_MSME.pdf
Presentation2_Agus Widyianto_MSME.pdfPresentation2_Agus Widyianto_MSME.pdf
Presentation2_Agus Widyianto_MSME.pdf
 
GDP Viva Slides
GDP Viva SlidesGDP Viva Slides
GDP Viva Slides
 
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
 
CO2 capture, transport and geological storage programmes
CO2 capture, transport and geological storage programmesCO2 capture, transport and geological storage programmes
CO2 capture, transport and geological storage programmes
 
Leed Modeling
Leed ModelingLeed Modeling
Leed Modeling
 
2015 - Building Simulation Best of 2015-03-23.pptx
2015 - Building Simulation Best of 2015-03-23.pptx2015 - Building Simulation Best of 2015-03-23.pptx
2015 - Building Simulation Best of 2015-03-23.pptx
 
Proposal Wide Blower No.1 & 2 with inverter
Proposal Wide Blower No.1 & 2  with inverterProposal Wide Blower No.1 & 2  with inverter
Proposal Wide Blower No.1 & 2 with inverter
 
climate consultant programme for cimulation
climate consultant programme for  cimulationclimate consultant programme for  cimulation
climate consultant programme for cimulation
 
Probabilistic & Source Characterization Techniques in AERMOD Compliance
Probabilistic & Source Characterization Techniques in AERMOD ComplianceProbabilistic & Source Characterization Techniques in AERMOD Compliance
Probabilistic & Source Characterization Techniques in AERMOD Compliance
 
Billet Surface Quality Improvement
Billet Surface Quality ImprovementBillet Surface Quality Improvement
Billet Surface Quality Improvement
 
DEVELOPMENT OF QUALITY IN CASTING BY MINIMIZING DFECTS
DEVELOPMENT OF QUALITY IN CASTING BY MINIMIZING DFECTSDEVELOPMENT OF QUALITY IN CASTING BY MINIMIZING DFECTS
DEVELOPMENT OF QUALITY IN CASTING BY MINIMIZING DFECTS
 
Ppttttt
PptttttPpttttt
Ppttttt
 
COSTMODEL_IDETC_2010_Jie
COSTMODEL_IDETC_2010_JieCOSTMODEL_IDETC_2010_Jie
COSTMODEL_IDETC_2010_Jie
 
Baf 2013 abc of jv3_ken thomson
Baf 2013 abc of jv3_ken thomsonBaf 2013 abc of jv3_ken thomson
Baf 2013 abc of jv3_ken thomson
 
SAS Global Coal-Fired Power Diagnostic Testing and Combustion Tuning
SAS Global Coal-Fired Power Diagnostic Testing and Combustion TuningSAS Global Coal-Fired Power Diagnostic Testing and Combustion Tuning
SAS Global Coal-Fired Power Diagnostic Testing and Combustion Tuning
 
Prefeseability study of petroleum field
Prefeseability study of petroleum fieldPrefeseability study of petroleum field
Prefeseability study of petroleum field
 
EXPERIMENTAL INVESTIGATION PERFORMANCE AND EMISSION ANALYSIS OF SINGLE CYLIND...
EXPERIMENTAL INVESTIGATION PERFORMANCE AND EMISSION ANALYSIS OF SINGLE CYLIND...EXPERIMENTAL INVESTIGATION PERFORMANCE AND EMISSION ANALYSIS OF SINGLE CYLIND...
EXPERIMENTAL INVESTIGATION PERFORMANCE AND EMISSION ANALYSIS OF SINGLE CYLIND...
 
NBEC 2014 - MURB Airtightness Study
NBEC 2014 - MURB Airtightness StudyNBEC 2014 - MURB Airtightness Study
NBEC 2014 - MURB Airtightness Study
 

Último

Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
kauryashika82
 
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
Anamikakaur10
 
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
dharasingh5698
 

Último (20)

VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
 
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
Call Girls Talegaon Dabhade Call Me 7737669865 Budget Friendly No Advance Boo...
 
Proposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
Proposed Amendments to Chapter 15, Article X: Wetland Conservation AreasProposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
Proposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
 
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...Presentation: Farmer-led climate adaptation - Project launch and overview by ...
Presentation: Farmer-led climate adaptation - Project launch and overview by ...
 
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
Call Now ☎ Russian Call Girls Connaught Place @ 9899900591 # Russian Escorts ...
 
Sector 18, Noida Call girls :8448380779 Model Escorts | 100% verified
Sector 18, Noida Call girls :8448380779 Model Escorts | 100% verifiedSector 18, Noida Call girls :8448380779 Model Escorts | 100% verified
Sector 18, Noida Call girls :8448380779 Model Escorts | 100% verified
 
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Wagholi ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
VIP Model Call Girls Chakan ( Pune ) Call ON 8005736733 Starting From 5K to 2...
 
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
(NEHA) Call Girls Navi Mumbai Call Now 8250077686 Navi Mumbai Escorts 24x7
 
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
 
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
 
Get Premium Attur Layout Call Girls (8005736733) 24x7 Rate 15999 with A/c Roo...
Get Premium Attur Layout Call Girls (8005736733) 24x7 Rate 15999 with A/c Roo...Get Premium Attur Layout Call Girls (8005736733) 24x7 Rate 15999 with A/c Roo...
Get Premium Attur Layout Call Girls (8005736733) 24x7 Rate 15999 with A/c Roo...
 
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
Call Now ☎️🔝 9332606886 🔝 Call Girls ❤ Service In Muzaffarpur Female Escorts ...
 
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
 
Green Marketing
Green MarketingGreen Marketing
Green Marketing
 
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
 
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Valsad 7001035870 Whatsapp Number, 24/07 Booking
 
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...Verified Trusted Kalyani Nagar Call Girls  8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
Verified Trusted Kalyani Nagar Call Girls 8005736733 𝐈𝐍𝐃𝐄𝐏𝐄𝐍𝐃𝐄𝐍𝐓 Call 𝐆𝐈𝐑𝐋 𝐕...
 
Cyclone Case Study Odisha 1999 Super Cyclone in India.
Cyclone Case Study Odisha 1999 Super Cyclone in India.Cyclone Case Study Odisha 1999 Super Cyclone in India.
Cyclone Case Study Odisha 1999 Super Cyclone in India.
 
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Magarpatta Call Me 7737669865 Budget Friendly No Advance Booking
 

IMPLICATIONS OF ACCURATE SOURCE CHARACTERIZATION ON PERMITTING FOR THE 1-HOUR NAAQS

  • 1. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants IMPLICATIONS OF ACCURATE SOURCE CHARACTERIZATION ON PERMITTING FOR THE 1-HR AND 24-HR NAAQS Ron Petersen, PhD, CCM CPP, Inc. 1415 Blue Spruce Drive Fort Collins, CO 80525 rpetersen@cppwind.com Cell: 970 690 1344
  • 2. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Outline • What is source characterization? • The forgotten but important factor – building dimensions • Where BPIP inputs are a problems • Example applications of AERMOD with better inputs (EBD) • Impact of better inputs (i.e., accurate source characterization)
  • 3. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Source Characterization 2013 EPA Draft SO2 NAAQS Designations Modeling Technical Assistance Document Common considerations • Stack height and location, stack parameters, emission rates, in-stack ratios, urban versus rural, etc. Often Overlooked (2 to 8 Reduction in Predicted Design Value) • “If stack locations and building information are not accurate, downwash will not be accurately accounted for in AERMOD.” • Building dimension inputs are critical!!!
  • 4. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Building Dimension Inputs & BPIP  BPIP uses building footprints and tier heights  Combines buildings  All structures become one single rectangular solid for each wind direction and each source  BPIP dimensions may not characterize the source and may give the wrong answer. BPIP Input
  • 5. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants AERMOD’s Building Downwash Algorithm • Used EPA wind tunnel data base and past literature • Developed analytical equations for cavity height, reattachment, streamline angle, wind speed and turbulence
  • 6. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants AERMOD’s Building Downwash Algorithm Only valid for certain building sizes • W/H 1 to 4 • L/H = 0 to 4 • Assumes all buildings are solid and rectangular
  • 7. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Building Dimension Inputs AERMOD Needs to Work The building shape and position that match the theory in AERMOD. BPIP will often not do this. Streamline figures from: Snyder, W.H. and R.E. Lawson, Jr.: Wind Tunnel Measurements of Flow Fields in the Vicinity of Buildings; 8th Joint Conference on Appl. of Air Poll. Met. With A&WMA; AMS, Boston, MA, 1994; pp. 244-250
  • 8. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants • Example BPIP Problems PW facility (blue), BPIP building dimensions (red) for stack S-344 (red) and envelope of the building cavity calculated by PRIME (yellow) for a) a wind direction of 90 degrees; and b) a wind direction of 140 degrees. ) BPIP Building Dimensions: H = 17 m L/H = 53 W/H = 34 BPIP Building Dimensions: H = 17 m L/H = 23 W/H = 63 a) b) BPIP Building Dimensions: H = 17 m L/H = 23 W/H = 63 BPIP Input in RED Site Plan and BPIP Result
  • 9. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Solution - Use EBD in Place of BPIP Dimensions • Equivalent Building Dimensions” (EBDs) are the dimensions that are input into AERMOD in place of BPIP dimensions to more accurately predict building wake effects • Determined using wind tunnel modeling 9
  • 10. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Current Regulatory Status of EBD October 24, 2011 Model Clearinghouse Review of EBD for AERMOD • “.. any EBD studies being considered should be discussed with the appropriate reviewing authority as early in the process as possible and that the Model Clearinghouse should also be engaged as early as possible.” • …. these wind tunnel EBD studies are classified as “source characterization studies.” • Roger Brode and George Bridgers, EPA Model Clearinghouse, receptive for those cases where AERMOD with BPIP inputs is not working – 2013 EPA R/S/L Modelers Workshop.
  • 11. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Basic Wind Tunnel Modeling Methodology •Obtain source/site data •Construct scale model – 3D Printing •Install model in wind tunnel and measure Cmax versus X
  • 12. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Measure Ground-level Concentrations Tracer from stack Max ground-level concentrations measured versus x
  • 13. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Measure Ground-level Concentrations Data taken until good fit and max obtained Automated Max GL Concentration Mapper
  • 14. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants EBD Used to Reduce Predicted AQ Impacts on Residential Tower downwind of Mirant Power Station, Alexandria, VA Residential Tower
  • 15. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Find EBD that gives same Max GL Concentration Profile as with Site Structures = - Input EBD Into AERMOD for wind directions of concern - AERMOD predicted impacts decreased by more than a factor of two. Mirant Power Station – Approved Study, Region 3 Wind Tunnel Testing Conducted with Site Structures and with EBD
  • 16. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants AECOM (David Shea) Conducted Field Study That Validated use of EBD – see AWMA 2007 papers
  • 17. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Example Application Very wide/narrow building Stack height: 47 m Building height: 31 m Property line in Red Emission rate: 1 g/s AERMOD RESULTS Five years of met data
  • 18. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Maximum Hourly Impact at Fenceline
  • 19. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants BPIP Input Analysis • W and L values > 5 times Hb for many wind directions (see red shading) • AERMOD will overpredict for these wind directions • Past EBD studies and theory show that Lmax and Wmax ≤ 4 Hb. • New BPIP input generated using this criterion • Input filed provided to modeling consultant to re-run AERMOD Flow Wind BUILDHGT BUILDWID BUILDLEN Vector Direction Hb W L XBADJ YBADJ Hb: W: L (Deg.) (Deg.) (m) (m) (m) (m) (m) 0 180 31.09 88.64 304.03 -144.87 -58.28 1.0 2.9 9.8 10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5 20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5 30 210 31.09 98.96 301.7 -115.52 -46.9 1.0 3.2 9.7 40 220 31.09 148.5 284.64 -99.38 -40.06 1.0 4.8 9.2 50 230 31.09 193.52 258.94 -80.23 -31.99 1.0 6.2 8.3 60 240 31.09 232.67 225.36 -58.63 -22.96 1.0 7.5 7.2 70 250 31.09 264.74 184.94 -35.26 -13.22 1.0 8.5 5.9 80 260 31.09 288.77 138.9 -10.81 -3.08 1.0 9.3 4.5 90 270 31.09 304.03 88.64 13.97 7.14 1.0 9.8 2.9 100 280 31.09 310.04 35.68 38.32 17.16 1.0 10.0 1.1 110 290 31.09 309.59 46.42 29.12 26.65 1.0 10.0 1.5 120 300 31.09 301.7 98.96 -2.58 35.33 1.0 9.7 3.2 130 310 31.09 284.64 148.5 -34.19 42.94 1.0 9.2 4.8 140 320 31.09 258.94 193.52 -64.77 49.24 1.0 8.3 6.2 150 330 31.09 225.36 232.67 -93.38 54.05 1.0 7.2 7.5 160 340 31.09 184.94 264.74 -119.15 57.21 1.0 5.9 8.5 170 350 31.09 138.9 288.77 -141.3 58.64 1.0 4.5 9.3 180 360 31.09 88.64 304.03 -159.16 58.28 1.0 2.9 9.8 190 10 24.99 30.53 11.47 -3.68 18.85 1.0 1.2 0.5 200 20 24.99 30.76 12.48 -7.49 18.91 1.0 1.2 0.5 210 30 31.09 98.96 301.7 -186.18 46.9 1.0 3.2 9.7 220 40 31.09 148.5 284.64 -185.26 40.06 1.0 4.8 9.2 230 50 31.09 193.52 258.94 -178.71 31.99 1.0 6.2 8.3 240 60 31.09 232.67 225.36 -166.73 22.95 1.0 7.5 7.2 250 70 31.09 264.74 184.94 -149.68 13.22 1.0 8.5 5.9 260 80 31.09 288.77 138.9 -128.09 3.08 1.0 9.3 4.5 270 90 31.09 304.03 88.64 -102.6 -7.14 1.0 9.8 2.9 280 100 31.09 310.04 35.68 -74 -17.16 1.0 10.0 1.1 290 110 31.09 309.59 46.42 -75.54 -26.65 1.0 10.0 1.5 300 120 31.09 301.7 98.96 -96.39 -35.33 1.0 9.7 3.2 310 130 31.09 284.64 148.5 -114.31 -42.94 1.0 9.2 4.8 320 140 31.09 258.94 193.52 -128.75 -49.24 1.0 8.3 6.2 330 150 31.09 225.36 232.67 -139.29 -54.05 1.0 7.2 7.5 340 160 31.09 184.94 264.74 -145.59 -57.21 1.0 5.9 8.5 350 170 31.09 138.9 288.77 -147.47 -58.64 1.0 4.5 9.3 BPIP Dimensions Aspect Ratio
  • 20. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants BPIP Input Analysis – Zoom In Flow Wind BUILDHGT BUILDWID BUILDLEN Vector Direction Hb W L XBADJ YBADJ Hb: W: L (Deg.) (Deg.) (m) (m) (m) (m) (m) 0 180 31.09 88.64 304.03 -144.87 -58.28 1.0 2.9 9.8 10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5 20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5 30 210 31.09 98.96 301.7 -115.52 -46.9 1.0 3.2 9.7 40 220 31.09 148.5 284.64 -99.38 -40.06 1.0 4.8 9.2 50 230 31.09 193.52 258.94 -80.23 -31.99 1.0 6.2 8.3 60 240 31.09 232.67 225.36 -58.63 -22.96 1.0 7.5 7.2 70 250 31.09 264.74 184.94 -35.26 -13.22 1.0 8.5 5.9 80 260 31.09 288.77 138.9 -10.81 -3.08 1.0 9.3 4.5 90 270 31.09 304.03 88.64 13.97 7.14 1.0 9.8 2.9 100 280 31.09 310.04 35.68 38.32 17.16 1.0 10.0 1.1 110 290 31.09 309.59 46.42 29.12 26.65 1.0 10.0 1.5 120 300 31.09 301.7 98.96 -2.58 35.33 1.0 9.7 3.2 BPIP Dimensions Aspect Ratio
  • 21. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Estimated EBD values • Estimated values to right used to modify AERMOD input file • AERMOD re-run with these building dimension inputs • AERMOD results below show wind tunnel study likely to help significantly AERMOD Building Dimension Inputs 1-hour 24-hour annual BPIP 15.19 8.20 0.89 Screening EBD Values 9.68 5.05 0.19 AERMOD Maximum predicted concentration (μg/m3 ) Flow Wind BUILDHGT BUILDWID BUILDLEN Vector Direction Hb W L XBADJ YBADJ Hb: W: L (Deg.) (Deg.) (m) (m) (m) (m) (m) 0 180 31.09 88.64 124.36 -144.87 -58.28 1.0 2.9 4.0 10 190 24.99 30.53 11.47 -7.79 -18.85 1.0 1.2 0.5 20 200 24.99 30.76 12.48 -4.99 -18.91 1.0 1.2 0.5 30 210 31.09 98.96 124.36 -115.52 -46.9 1.0 3.2 4.0 40 220 31.09 124.36 124.36 -99.38 -40.06 1.0 4.0 4.0 50 230 31.09 124.36 124.36 -80.23 -31.99 1.0 4.0 4.0 60 240 31.09 124.36 124.36 -58.63 -22.96 1.0 4.0 4.0 70 250 31.09 124.36 124.36 -35.26 -13.22 1.0 4.0 4.0 80 260 31.09 124.36 124.36 -10.81 -3.08 1.0 4.0 4.0 90 270 31.09 124.36 88.64 13.97 7.14 1.0 4.0 2.9 100 280 31.09 124.36 35.68 38.32 17.16 1.0 4.0 1.1 110 290 31.09 124.36 46.42 29.12 26.65 1.0 4.0 1.5 120 300 31.09 124.36 98.96 -2.58 35.33 1.0 4.0 3.2 130 310 31.09 124.36 124.36 -34.19 42.94 1.0 4.0 4.0 140 320 31.09 124.36 124.36 -64.77 49.24 1.0 4.0 4.0 150 330 31.09 124.36 124.36 -93.38 54.05 1.0 4.0 4.0 160 340 31.09 124.36 124.36 -119.15 57.21 1.0 4.0 4.0 170 350 31.09 124.36 124.36 -141.3 58.64 1.0 4.0 4.0 180 360 31.09 88.64 124.36 -159.16 58.28 1.0 2.9 4.0 190 10 24.99 30.53 11.47 -3.68 18.85 1.0 1.2 0.5 200 20 24.99 30.76 12.48 -7.49 18.91 1.0 1.2 0.5 210 30 31.09 98.96 124.36 -186.18 46.9 1.0 3.2 4.0 220 40 31.09 124.36 124.36 -185.26 40.06 1.0 4.0 4.0 230 50 31.09 124.36 124.36 -178.71 31.99 1.0 4.0 4.0 240 60 31.09 124.36 124.36 -166.73 22.95 1.0 4.0 4.0 250 70 31.09 124.36 124.36 -149.68 13.22 1.0 4.0 4.0 260 80 31.09 124.36 124.36 -128.09 3.08 1.0 4.0 4.0 270 90 31.09 124.36 88.64 -102.6 -7.14 1.0 4.0 2.9 280 100 31.09 124.36 35.68 -74 -17.16 1.0 4.0 1.1 290 110 31.09 124.36 46.42 -75.54 -26.65 1.0 4.0 1.5 300 120 31.09 124.36 98.96 -96.39 -35.33 1.0 4.0 3.2 310 130 31.09 124.36 124.36 -114.31 -42.94 1.0 4.0 4.0 320 140 31.09 124.36 124.36 -128.75 -49.24 1.0 4.0 4.0 330 150 31.09 124.36 124.36 -139.29 -54.05 1.0 4.0 4.0 340 160 31.09 124.36 124.36 -145.59 -57.21 1.0 4.0 4.0 350 170 31.09 124.36 124.36 -147.47 -58.64 1.0 4.0 4.0 Estimated EBD using Max Width and Length Criteria of 4 times the Height Aspect Ratio
  • 22. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants AERMOD Results With Wind Tunnel EBD Very wide/narrow building Stack height: 47 m Building height: 31 m Property line in Red Emission rate: 1 g/s AERMOD RESULTS Five years of met data AERMOD Building Dimension Inputs 1-hour 24-hour annual BPIP 15.19 8.20 0.89 Wind Tunnel EBD 3.99 1.88 0.18 Reduction Factor 3.80 4.37 4.93 AERMOD Maximum predicted
  • 23. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Stack at Industrial Facility Stack height = 27 m Q = 1 g/s Building height = 17 m Building width and/or length > 200 m 5 years of meteorological data AERMOD RESULTS SHORT LARGE BUILDING Building Input 1-hr 3-hr 24-hr annual BPIP 129.1 101.7 38.2 4.0 Wind Tunnel EBD 27.3 17.8 7.9 0.5 Reduction Factor 4.7 5.7 4.8 7.9 Maximum concentration (ug/m3 )
  • 24. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants BPIP Max = 38.2 ug/m3 EBD Max = 8.1ug/m3 AERMOD Contours: 24-hr max
  • 25. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Stack height: 45 m Structure height: 61 m Emission rate: 1 g/s Five years of met data Stack AERMOD Results Lattice Structure Building Input 1-hour 24-hour annual BPIP 23.21 5.51 0.37 Wind Tunnel EBD 7.72 2.36 0.11 Reduction Factor 3.01 2.33 3.51 Maximum Concentration Results
  • 26. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants FACTOR of 4 to 8 reduction when EBD used Short building with a large foot print FACTOR of 2 to 4 reduction when EBD used Hyperbolic cooling towers Typical AERMOD Overprediction Factors When Using BPIP Inputs
  • 27. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Typical AERMOD Overprediction Factors When Using BPIP Inputs FACTOR of 2 to 5 reduction when EBD used Very Wide/Narrow Buildings FACTOR of 2 to 3.5 reduction when EBD used Lattice Structures
  • 28. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Result of Accurate Building Dimension Source Characterization • More accurate concentration estimates • Estimates that are 2 to 8 times lower for appropriate cases Short/wide/long Streamlined Wide Lattice
  • 29. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants Questions? Ron Petersen, Ph.D., CCM CPP, Inc rpetersen@cppwind.com 970 690 1344
  • 30. EUEC 2015, San Diego, CAWind Engineering and Air Quality Consultants EBD Background • Several studies conducted and approved using original guidance for ISC applications • Amoco Whiting Refinery, Region 5, 1990 • Public Service Electric & Gas, Region 2, 1993 • Cape Industries, Region 4, 1993 • Cambridge Electric Plant, Region 1, 1993 • District Energy, Region 5, 1993 • Hoechst Celanese Celco Plant, Region 3, 1994 • Pleasants Power, Region 3, 2002 • Studies conducted using AERMOD • Hawaiian Electric (Approved), Region 9, 1998 • Mirant Power Station (Approved), Region 3, 2006 • Cheswick Power Plant (Approved), Region 3, 2006 • Alcoa (Not Approved), Region 7, 2010 • Chevron (Approved), Region 4, 2012