CFD webinar
Pressure Coefficients on
Building Facades for
Building Simulation
In today’s presentation we will explore the
importance of accurate wind pressure
coefficients, and why these are critical in
building design.
This is especially important if you use any
building simulation tools for thermal
modelling, ventilation design, and
compliance.
Wind pressure
coefficients
Why are wind pressure coefficients (Cp) so important?
1. The wind pressure at an opening (Pw) and hence ΔP - difference between
internal and external pressure determines how building simulation tools
calculate air flow (natural ventilation, fresh air etc.) through windows/openings.
1. This air exchange will have a ΔT - difference between internal and external
temperature
1. Therefore the amount of air coming in/out of openings has a direct impact on
building:
a. Fresh air and air exchanges - are you calculating the ventilation and air
quality values correctly?
a. Heating and cooling loads - because the amount of air coming in/out of
your building at a certain temperature will either add or remove
thermal energy from your spaces
a. Energy - Gas and electricity due to heating and cooling costs
a. Thermal comfort - air speed, distribution, temperature and quantity of
flow rate.
1. Pw is dependent on Cp
2. Pw is used to calculate ΔP
3. ΔP is used to calculate mass flow rate exchange between
inside and outside (There is also a ΔT)
4. Mass flow rate is an input into the calculation of:
a. Heating load
b. Cooling load
c. Overall energy (KWh) and Cost ($)
d. Thermal comfort
e. Overall zone and building energy balance
f. Impacts on air velocities in rooms for comfort
purposes
Imagine a 50% error in your Cp and how that error propagates
through all of the above
Why are wind pressure coefficients (Cp) so important?
What factors should you watch out for?
Most thermal modelling and building simulation tools use simple airflow
network models to calculate bulk air movement. They DO NOT capture the
following effects:
● Wind turbulence
● External wind conditions
● Local building context
● Terrain is an oversimplified constant
● Exposure types are poorly understood and seldom applied. They are
also based on very simplified wind tunnel testing conducted a long
time ago.
Have you ever thought of how your wind pressure coefficients can be more
accurately calculated?
Setup and run a
simulation
Pressure
coefficient
results
Import into thermal
modelling solution
1
3-Part Workflow
1. Run a PWC simulation on SimScale.
2. Download results and calculate the pressure
coefficients in ParaView from the pressure results.
3. Query the results in ParaView and use the results
to obtain thermal model’s with higher accuracy.
How do we assess pressure coefficients
on building facades?
2
3
The Workflow for Pressure Coefficients
Pressure Coefficients on Building Facades for Building
Simulation
Step 1
● Traditionally the process for running a CFD
simulation has been very difficult.
● SimScale has simplified this into a 3 step process
and considered all the best practices and
documentation.
● A simulation can be setup and run within 10
minutes in most cases.
Setup
Step 2
Pressure Coefficient
Results
● To obtain pressure coefficients, the results need to
be post processed
● The pressure results are normalised using the
wind speed at the same height in the wind profile.
● Results can be queried by simply selecting points
on the building.
These pressure coefficients can be used for many
different things including increasing the accuracy of
thermal models.
Step 3
Import Into Thermal
Modelling Solution
Setting up a simulation
Pressure Coefficients on Building Facades for Building
Simulation
Define region
Define wind rose
Define pedestrian
zones
1
3
2-Minute Setup
It’s that simple.
1. Define region
2. Define wind rose
3. Define pedestrian zones
How simple can it be?
2
Step 1
● Position and size the cylindrical region of interest
● Define which direction is North
Define City Region
Step 2
Define Wind Rose
Location was searched by address and the wind data
automatically imported from the connected database
(Wind speed and direction).
Step 3
● Pedestrian region was set to be 1.5m from the
floor.
● All terrain at pedestrian level was select to be
offset.
● In more complex scenarios, terraces, balconies or
planes at set heights can be used to record results.
Define pedestrian region
Doing this yourself
● This can of course all be done by you!
● The Example project setup is here
● The ParaView state is here
This will allow you to create pressure coefficients to
the eurocode wind profile, but can be modified to
suit your needs.
Useful Links
● All these wind directions are computed in parallel,
a transient (real time wind) simulation takes less
than 2 hours.
● Results are exported on the building surfaces.
8 Directions, At Once!
Results
● Pressure coefficients on windward side are higher
than 1 and on the leeward side, less than 1 as
expected.
● A pattern is observed that on the windward face of
the building the pressure coefficients are fairly
uniform.
● On the next slide we will look at how this alters
due to shielding.
Wind Pressure
Coefficients
Results
South facade h/H = 0.2 S Cp 0.18
● When the wind is coming from the south the
pressure is mostly unaffected by the closely
surrounding buildings.
● This is different when there is an easterly wind,
the shielding from the nearby building on the
windward side causes the pressure coefficient to
drop at building height.
Wind Pressure
Coefficients
Results
Results at 0° for SW
Direction
Nearby
Building
When comparing to pressure coefficients obtained in building
simulation models we see the following:
● Pressure higher up the building is much higher in
comparison to standard methods used, where flow is
much faster than expected for this wind profile due
to upstream obstruction.
● Lower down, it is much less as surrounding buildings
are actively obstructing the flow.
● Up to 100% difference in Cp values across the length
and width of the building.
● Imagine the error which propagates through to
calculating air flow rates, loads, comfort and more!
Summary
How will this impact on your:
○ Overheating assessments?
○ Fresh air rates?
○ Energy/Loads?
○ Compliance?

Más contenido relacionado

La actualidad más candente

Green building concept
Green building conceptGreen building concept
Green building conceptSumit Gupta
 
Ventilation system of building
Ventilation system of buildingVentilation system of building
Ventilation system of buildingSulieman KOHISTANI
 
Pedestrian Wind Comfort Assessment for Master Planning
Pedestrian Wind Comfort Assessment for Master Planning Pedestrian Wind Comfort Assessment for Master Planning
Pedestrian Wind Comfort Assessment for Master Planning SimScale
 
GREEN BUILDINGS
GREEN BUILDINGSGREEN BUILDINGS
GREEN BUILDINGSRobbySahoo
 
The Economics of Green Building
The Economics of Green BuildingThe Economics of Green Building
The Economics of Green Buildingnilskok
 
Lecture 5 designing building envelope
Lecture 5 designing building envelopeLecture 5 designing building envelope
Lecture 5 designing building envelopeNedhal Al-Tamimi
 
Heating & Cooling Loads Calculations and HVAC Equipment Sizing
Heating & Cooling Loads Calculations  and HVAC Equipment SizingHeating & Cooling Loads Calculations  and HVAC Equipment Sizing
Heating & Cooling Loads Calculations and HVAC Equipment SizingIES VE
 
Hi-Tech Building Systems
Hi-Tech Building SystemsHi-Tech Building Systems
Hi-Tech Building SystemsDori Schmitz
 
Natural Ventilation and Hydronic Cooling in Humid Climates
Natural Ventilation and Hydronic Cooling in Humid ClimatesNatural Ventilation and Hydronic Cooling in Humid Climates
Natural Ventilation and Hydronic Cooling in Humid Climatesaiahouston
 
Life cycle analysis of hvac desining multi split vrf system
Life cycle analysis of hvac desining multi split vrf systemLife cycle analysis of hvac desining multi split vrf system
Life cycle analysis of hvac desining multi split vrf systemSYED KHURSHID ALAM ARZOO
 
Lecture 11 computer simulation in buildings
Lecture 11 computer simulation in buildingsLecture 11 computer simulation in buildings
Lecture 11 computer simulation in buildingsNedhal Al-Tamimi
 
Energy Conservation Building Code ECBC
Energy Conservation Building Code ECBCEnergy Conservation Building Code ECBC
Energy Conservation Building Code ECBCAmar Relan
 
Indoor Air Quality for Buildings
Indoor Air Quality for BuildingsIndoor Air Quality for Buildings
Indoor Air Quality for BuildingsCamfil UK
 

La actualidad más candente (20)

Why Consider a Green Roof?
Why Consider a Green Roof?Why Consider a Green Roof?
Why Consider a Green Roof?
 
passive cooling
passive coolingpassive cooling
passive cooling
 
Green building concept
Green building conceptGreen building concept
Green building concept
 
Ventilation system of building
Ventilation system of buildingVentilation system of building
Ventilation system of building
 
Pedestrian Wind Comfort Assessment for Master Planning
Pedestrian Wind Comfort Assessment for Master Planning Pedestrian Wind Comfort Assessment for Master Planning
Pedestrian Wind Comfort Assessment for Master Planning
 
GREEN BUILDINGS
GREEN BUILDINGSGREEN BUILDINGS
GREEN BUILDINGS
 
The Economics of Green Building
The Economics of Green BuildingThe Economics of Green Building
The Economics of Green Building
 
Lecture 5 designing building envelope
Lecture 5 designing building envelopeLecture 5 designing building envelope
Lecture 5 designing building envelope
 
Heating & Cooling Loads Calculations and HVAC Equipment Sizing
Heating & Cooling Loads Calculations  and HVAC Equipment SizingHeating & Cooling Loads Calculations  and HVAC Equipment Sizing
Heating & Cooling Loads Calculations and HVAC Equipment Sizing
 
Green building
Green buildingGreen building
Green building
 
Bs 8118-1
Bs 8118-1Bs 8118-1
Bs 8118-1
 
Hi-Tech Building Systems
Hi-Tech Building SystemsHi-Tech Building Systems
Hi-Tech Building Systems
 
Energy simulation & analysis
Energy simulation & analysisEnergy simulation & analysis
Energy simulation & analysis
 
Natural Ventilation and Hydronic Cooling in Humid Climates
Natural Ventilation and Hydronic Cooling in Humid ClimatesNatural Ventilation and Hydronic Cooling in Humid Climates
Natural Ventilation and Hydronic Cooling in Humid Climates
 
Life cycle analysis of hvac desining multi split vrf system
Life cycle analysis of hvac desining multi split vrf systemLife cycle analysis of hvac desining multi split vrf system
Life cycle analysis of hvac desining multi split vrf system
 
Passive design2
Passive design2Passive design2
Passive design2
 
Lecture 11 computer simulation in buildings
Lecture 11 computer simulation in buildingsLecture 11 computer simulation in buildings
Lecture 11 computer simulation in buildings
 
Energy Conservation Building Code ECBC
Energy Conservation Building Code ECBCEnergy Conservation Building Code ECBC
Energy Conservation Building Code ECBC
 
Wind loads
Wind loadsWind loads
Wind loads
 
Indoor Air Quality for Buildings
Indoor Air Quality for BuildingsIndoor Air Quality for Buildings
Indoor Air Quality for Buildings
 

Similar a Pressure Coefficients on Building Facades for Building Simulation

SimScale to IES for Building Simulation
SimScale to IES for Building SimulationSimScale to IES for Building Simulation
SimScale to IES for Building SimulationSimScale
 
Wec updates 2010
Wec updates 2010Wec updates 2010
Wec updates 2010David Olson
 
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...Stephane Meteodyn
 
Habitat for Humanity HVAC System Analysis
Habitat for Humanity HVAC System AnalysisHabitat for Humanity HVAC System Analysis
Habitat for Humanity HVAC System AnalysisMatt Bartholomew
 
Wind load calculation
Wind load calculationWind load calculation
Wind load calculationGodfrey James
 
Thermal Comfort Assessment: Comply with EN 15251 and EPBD
Thermal Comfort Assessment: Comply with EN 15251 and EPBDThermal Comfort Assessment: Comply with EN 15251 and EPBD
Thermal Comfort Assessment: Comply with EN 15251 and EPBDSimScale
 
Pedestrian wind comfort in urban area with numerical tools
Pedestrian wind comfort in urban area with numerical toolsPedestrian wind comfort in urban area with numerical tools
Pedestrian wind comfort in urban area with numerical toolsStephane Meteodyn
 
Building performance analysis system IES VE main features overview
Building performance analysis system IES VE main features overviewBuilding performance analysis system IES VE main features overview
Building performance analysis system IES VE main features overviewStatybos Akademija
 
Design of duct for a three storey retail shop
Design of duct for a three storey retail shopDesign of duct for a three storey retail shop
Design of duct for a three storey retail shopIRJET Journal
 
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...IRJET Journal
 
IRJET- A Case Study of Cooling Load Estimation of an Auditorium
IRJET- A Case Study of Cooling Load Estimation of an AuditoriumIRJET- A Case Study of Cooling Load Estimation of an Auditorium
IRJET- A Case Study of Cooling Load Estimation of an AuditoriumIRJET Journal
 
IRJET - Portable Atmospheric Water Generator
IRJET -  	  Portable Atmospheric Water GeneratorIRJET -  	  Portable Atmospheric Water Generator
IRJET - Portable Atmospheric Water GeneratorIRJET Journal
 
IRJET- Performance Analysis of Converging Diverging Nozzle
IRJET- Performance Analysis of Converging Diverging NozzleIRJET- Performance Analysis of Converging Diverging Nozzle
IRJET- Performance Analysis of Converging Diverging NozzleIRJET Journal
 
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...IRJET Journal
 
Pu Hall Calculations_2
Pu Hall Calculations_2Pu Hall Calculations_2
Pu Hall Calculations_2fraz mirza
 
Example of natural air ventilation using CFD modelling
Example of natural air ventilation using CFD modellingExample of natural air ventilation using CFD modelling
Example of natural air ventilation using CFD modellingStephane Meteodyn
 
Green Building Awareness HVAC
Green Building Awareness HVAC Green Building Awareness HVAC
Green Building Awareness HVAC AKSHAY SHARMA
 
Classroom Ventilation Optimization with SAV Systems
Classroom Ventilation Optimization with SAV SystemsClassroom Ventilation Optimization with SAV Systems
Classroom Ventilation Optimization with SAV SystemsSimScale
 
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...IRJET Journal
 
Stack Effect and Ventilation System Design
Stack Effect and Ventilation System Design Stack Effect and Ventilation System Design
Stack Effect and Ventilation System Design SimScale
 

Similar a Pressure Coefficients on Building Facades for Building Simulation (20)

SimScale to IES for Building Simulation
SimScale to IES for Building SimulationSimScale to IES for Building Simulation
SimScale to IES for Building Simulation
 
Wec updates 2010
Wec updates 2010Wec updates 2010
Wec updates 2010
 
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...
Combined CFD-Mean energy balance methode to thermal comfort assessment of bui...
 
Habitat for Humanity HVAC System Analysis
Habitat for Humanity HVAC System AnalysisHabitat for Humanity HVAC System Analysis
Habitat for Humanity HVAC System Analysis
 
Wind load calculation
Wind load calculationWind load calculation
Wind load calculation
 
Thermal Comfort Assessment: Comply with EN 15251 and EPBD
Thermal Comfort Assessment: Comply with EN 15251 and EPBDThermal Comfort Assessment: Comply with EN 15251 and EPBD
Thermal Comfort Assessment: Comply with EN 15251 and EPBD
 
Pedestrian wind comfort in urban area with numerical tools
Pedestrian wind comfort in urban area with numerical toolsPedestrian wind comfort in urban area with numerical tools
Pedestrian wind comfort in urban area with numerical tools
 
Building performance analysis system IES VE main features overview
Building performance analysis system IES VE main features overviewBuilding performance analysis system IES VE main features overview
Building performance analysis system IES VE main features overview
 
Design of duct for a three storey retail shop
Design of duct for a three storey retail shopDesign of duct for a three storey retail shop
Design of duct for a three storey retail shop
 
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...
Heat Load Calculation and Coordination of Multispecialty Hospital Using Revit...
 
IRJET- A Case Study of Cooling Load Estimation of an Auditorium
IRJET- A Case Study of Cooling Load Estimation of an AuditoriumIRJET- A Case Study of Cooling Load Estimation of an Auditorium
IRJET- A Case Study of Cooling Load Estimation of an Auditorium
 
IRJET - Portable Atmospheric Water Generator
IRJET -  	  Portable Atmospheric Water GeneratorIRJET -  	  Portable Atmospheric Water Generator
IRJET - Portable Atmospheric Water Generator
 
IRJET- Performance Analysis of Converging Diverging Nozzle
IRJET- Performance Analysis of Converging Diverging NozzleIRJET- Performance Analysis of Converging Diverging Nozzle
IRJET- Performance Analysis of Converging Diverging Nozzle
 
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...
IRJET- Duct Designing in Air Conditioning System and its Impact on System Per...
 
Pu Hall Calculations_2
Pu Hall Calculations_2Pu Hall Calculations_2
Pu Hall Calculations_2
 
Example of natural air ventilation using CFD modelling
Example of natural air ventilation using CFD modellingExample of natural air ventilation using CFD modelling
Example of natural air ventilation using CFD modelling
 
Green Building Awareness HVAC
Green Building Awareness HVAC Green Building Awareness HVAC
Green Building Awareness HVAC
 
Classroom Ventilation Optimization with SAV Systems
Classroom Ventilation Optimization with SAV SystemsClassroom Ventilation Optimization with SAV Systems
Classroom Ventilation Optimization with SAV Systems
 
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...
IRJET- Experimental Model Design and Simulation of Air Conditioning System fo...
 
Stack Effect and Ventilation System Design
Stack Effect and Ventilation System Design Stack Effect and Ventilation System Design
Stack Effect and Ventilation System Design
 

Más de SimScale

FEA for Early Stage Design
FEA for Early Stage DesignFEA for Early Stage Design
FEA for Early Stage DesignSimScale
 
Hybrid Ventilation using CFD Simulation in the Cloud
Hybrid Ventilation using CFD Simulation in the CloudHybrid Ventilation using CFD Simulation in the Cloud
Hybrid Ventilation using CFD Simulation in the CloudSimScale
 
Simulation for Passively Cooled LED Design
Simulation for Passively Cooled LED DesignSimulation for Passively Cooled LED Design
Simulation for Passively Cooled LED DesignSimScale
 
Design Buildings Faster by Harnessing the Power of the Cloud
Design Buildings Faster by Harnessing the Power of the CloudDesign Buildings Faster by Harnessing the Power of the Cloud
Design Buildings Faster by Harnessing the Power of the CloudSimScale
 
Fast & Easy Electronics Thermal Management
Fast & Easy Electronics Thermal ManagementFast & Easy Electronics Thermal Management
Fast & Easy Electronics Thermal ManagementSimScale
 
Smart Data Center Design
Smart Data Center DesignSmart Data Center Design
Smart Data Center DesignSimScale
 
SimScale Demo and Discussion on External AEC
SimScale Demo and Discussion on External AECSimScale Demo and Discussion on External AEC
SimScale Demo and Discussion on External AECSimScale
 
SimScale Demo and Discussion on Internal AEC
SimScale Demo and Discussion on Internal AECSimScale Demo and Discussion on Internal AEC
SimScale Demo and Discussion on Internal AECSimScale
 
Conjugate Heat Transfer Best Practices in SimScale
Conjugate Heat Transfer Best Practices in SimScaleConjugate Heat Transfer Best Practices in SimScale
Conjugate Heat Transfer Best Practices in SimScaleSimScale
 
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFD
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFDEvaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFD
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFDSimScale
 
Early-Stage Design Simulation for Architects
Early-Stage Design Simulation for ArchitectsEarly-Stage Design Simulation for Architects
Early-Stage Design Simulation for ArchitectsSimScale
 
An Introduction to Electronics Cooling
An Introduction to Electronics CoolingAn Introduction to Electronics Cooling
An Introduction to Electronics CoolingSimScale
 
Accélérer le développement produit via la simulation dans le Cloud avec SimScale
Accélérer le développement produit via la simulation dans le Cloud avec SimScaleAccélérer le développement produit via la simulation dans le Cloud avec SimScale
Accélérer le développement produit via la simulation dans le Cloud avec SimScaleSimScale
 
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...SimScale
 
SimScale: Unparalleled CFD Speeds with Parallel Computing
SimScale: Unparalleled CFD Speeds with Parallel ComputingSimScale: Unparalleled CFD Speeds with Parallel Computing
SimScale: Unparalleled CFD Speeds with Parallel ComputingSimScale
 
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...SimScale
 
Basics of building aerodynamics & their effects on pedestrian comfort
Basics of building aerodynamics & their effects on pedestrian comfortBasics of building aerodynamics & their effects on pedestrian comfort
Basics of building aerodynamics & their effects on pedestrian comfortSimScale
 
Plasticity and Nonlinear Materials in FEA
Plasticity and Nonlinear Materials in FEAPlasticity and Nonlinear Materials in FEA
Plasticity and Nonlinear Materials in FEASimScale
 
Thermal Resistance Modelling with SimScale
Thermal Resistance Modelling with SimScaleThermal Resistance Modelling with SimScale
Thermal Resistance Modelling with SimScaleSimScale
 
Mesh Generation with SimScale
Mesh Generation with SimScaleMesh Generation with SimScale
Mesh Generation with SimScaleSimScale
 

Más de SimScale (20)

FEA for Early Stage Design
FEA for Early Stage DesignFEA for Early Stage Design
FEA for Early Stage Design
 
Hybrid Ventilation using CFD Simulation in the Cloud
Hybrid Ventilation using CFD Simulation in the CloudHybrid Ventilation using CFD Simulation in the Cloud
Hybrid Ventilation using CFD Simulation in the Cloud
 
Simulation for Passively Cooled LED Design
Simulation for Passively Cooled LED DesignSimulation for Passively Cooled LED Design
Simulation for Passively Cooled LED Design
 
Design Buildings Faster by Harnessing the Power of the Cloud
Design Buildings Faster by Harnessing the Power of the CloudDesign Buildings Faster by Harnessing the Power of the Cloud
Design Buildings Faster by Harnessing the Power of the Cloud
 
Fast & Easy Electronics Thermal Management
Fast & Easy Electronics Thermal ManagementFast & Easy Electronics Thermal Management
Fast & Easy Electronics Thermal Management
 
Smart Data Center Design
Smart Data Center DesignSmart Data Center Design
Smart Data Center Design
 
SimScale Demo and Discussion on External AEC
SimScale Demo and Discussion on External AECSimScale Demo and Discussion on External AEC
SimScale Demo and Discussion on External AEC
 
SimScale Demo and Discussion on Internal AEC
SimScale Demo and Discussion on Internal AECSimScale Demo and Discussion on Internal AEC
SimScale Demo and Discussion on Internal AEC
 
Conjugate Heat Transfer Best Practices in SimScale
Conjugate Heat Transfer Best Practices in SimScaleConjugate Heat Transfer Best Practices in SimScale
Conjugate Heat Transfer Best Practices in SimScale
 
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFD
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFDEvaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFD
Evaluating the Thermal Performance of Lighting Solutions With Cloud-Based CFD
 
Early-Stage Design Simulation for Architects
Early-Stage Design Simulation for ArchitectsEarly-Stage Design Simulation for Architects
Early-Stage Design Simulation for Architects
 
An Introduction to Electronics Cooling
An Introduction to Electronics CoolingAn Introduction to Electronics Cooling
An Introduction to Electronics Cooling
 
Accélérer le développement produit via la simulation dans le Cloud avec SimScale
Accélérer le développement produit via la simulation dans le Cloud avec SimScaleAccélérer le développement produit via la simulation dans le Cloud avec SimScale
Accélérer le développement produit via la simulation dans le Cloud avec SimScale
 
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
Using SimScale for Demonstrating Compliance With LEED, BREEAM & the WELL Buil...
 
SimScale: Unparalleled CFD Speeds with Parallel Computing
SimScale: Unparalleled CFD Speeds with Parallel ComputingSimScale: Unparalleled CFD Speeds with Parallel Computing
SimScale: Unparalleled CFD Speeds with Parallel Computing
 
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...
Simulating the Performance of the Unique MicroLouvre™ for Low Energy Building...
 
Basics of building aerodynamics & their effects on pedestrian comfort
Basics of building aerodynamics & their effects on pedestrian comfortBasics of building aerodynamics & their effects on pedestrian comfort
Basics of building aerodynamics & their effects on pedestrian comfort
 
Plasticity and Nonlinear Materials in FEA
Plasticity and Nonlinear Materials in FEAPlasticity and Nonlinear Materials in FEA
Plasticity and Nonlinear Materials in FEA
 
Thermal Resistance Modelling with SimScale
Thermal Resistance Modelling with SimScaleThermal Resistance Modelling with SimScale
Thermal Resistance Modelling with SimScale
 
Mesh Generation with SimScale
Mesh Generation with SimScaleMesh Generation with SimScale
Mesh Generation with SimScale
 

Último

Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...Call Girls in Nagpur High Profile
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxJuliansyahHarahap1
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptMsecMca
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Standamitlee9823
 
Unit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdfUnit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdfRagavanV2
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performancesivaprakash250
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordAsst.prof M.Gokilavani
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Bookingdharasingh5698
 
Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdfKamal Acharya
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXssuser89054b
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...SUHANI PANDEY
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...Call Girls in Nagpur High Profile
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VDineshKumar4165
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfRagavanV2
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptNANDHAKUMARA10
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptDineshKumar4165
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdfKamal Acharya
 

Último (20)

Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...Booking open Available Pune Call Girls Koregaon Park  6297143586 Call Hot Ind...
Booking open Available Pune Call Girls Koregaon Park 6297143586 Call Hot Ind...
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
notes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.pptnotes on Evolution Of Analytic Scalability.ppt
notes on Evolution Of Analytic Scalability.ppt
 
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night StandCall Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
Call Girls In Bangalore ☎ 7737669865 🥵 Book Your One night Stand
 
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
(INDIRA) Call Girl Bhosari Call Now 8617697112 Bhosari Escorts 24x7
 
Unit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdfUnit 2- Effective stress & Permeability.pdf
Unit 2- Effective stress & Permeability.pdf
 
UNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its PerformanceUNIT - IV - Air Compressors and its Performance
UNIT - IV - Air Compressors and its Performance
 
NFPA 5000 2024 standard .
NFPA 5000 2024 standard                                  .NFPA 5000 2024 standard                                  .
NFPA 5000 2024 standard .
 
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete RecordCCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
CCS335 _ Neural Networks and Deep Learning Laboratory_Lab Complete Record
 
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 BookingVIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
VIP Call Girls Palanpur 7001035870 Whatsapp Number, 24/07 Booking
 
Online banking management system project.pdf
Online banking management system project.pdfOnline banking management system project.pdf
Online banking management system project.pdf
 
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX
 
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
VIP Model Call Girls Kothrud ( Pune ) Call ON 8005736733 Starting From 5K to ...
 
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...Booking open Available Pune Call Girls Pargaon  6297143586 Call Hot Indian Gi...
Booking open Available Pune Call Girls Pargaon 6297143586 Call Hot Indian Gi...
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Unit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdfUnit 1 - Soil Classification and Compaction.pdf
Unit 1 - Soil Classification and Compaction.pdf
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
(INDIRA) Call Girl Aurangabad Call Now 8617697112 Aurangabad Escorts 24x7
 
University management System project report..pdf
University management System project report..pdfUniversity management System project report..pdf
University management System project report..pdf
 

Pressure Coefficients on Building Facades for Building Simulation

  • 1. CFD webinar Pressure Coefficients on Building Facades for Building Simulation
  • 2. In today’s presentation we will explore the importance of accurate wind pressure coefficients, and why these are critical in building design. This is especially important if you use any building simulation tools for thermal modelling, ventilation design, and compliance. Wind pressure coefficients
  • 3. Why are wind pressure coefficients (Cp) so important? 1. The wind pressure at an opening (Pw) and hence ΔP - difference between internal and external pressure determines how building simulation tools calculate air flow (natural ventilation, fresh air etc.) through windows/openings. 1. This air exchange will have a ΔT - difference between internal and external temperature 1. Therefore the amount of air coming in/out of openings has a direct impact on building: a. Fresh air and air exchanges - are you calculating the ventilation and air quality values correctly? a. Heating and cooling loads - because the amount of air coming in/out of your building at a certain temperature will either add or remove thermal energy from your spaces a. Energy - Gas and electricity due to heating and cooling costs a. Thermal comfort - air speed, distribution, temperature and quantity of flow rate.
  • 4. 1. Pw is dependent on Cp 2. Pw is used to calculate ΔP 3. ΔP is used to calculate mass flow rate exchange between inside and outside (There is also a ΔT) 4. Mass flow rate is an input into the calculation of: a. Heating load b. Cooling load c. Overall energy (KWh) and Cost ($) d. Thermal comfort e. Overall zone and building energy balance f. Impacts on air velocities in rooms for comfort purposes Imagine a 50% error in your Cp and how that error propagates through all of the above Why are wind pressure coefficients (Cp) so important?
  • 5. What factors should you watch out for? Most thermal modelling and building simulation tools use simple airflow network models to calculate bulk air movement. They DO NOT capture the following effects: ● Wind turbulence ● External wind conditions ● Local building context ● Terrain is an oversimplified constant ● Exposure types are poorly understood and seldom applied. They are also based on very simplified wind tunnel testing conducted a long time ago. Have you ever thought of how your wind pressure coefficients can be more accurately calculated?
  • 6. Setup and run a simulation Pressure coefficient results Import into thermal modelling solution 1 3-Part Workflow 1. Run a PWC simulation on SimScale. 2. Download results and calculate the pressure coefficients in ParaView from the pressure results. 3. Query the results in ParaView and use the results to obtain thermal model’s with higher accuracy. How do we assess pressure coefficients on building facades? 2 3
  • 7. The Workflow for Pressure Coefficients Pressure Coefficients on Building Facades for Building Simulation
  • 8. Step 1 ● Traditionally the process for running a CFD simulation has been very difficult. ● SimScale has simplified this into a 3 step process and considered all the best practices and documentation. ● A simulation can be setup and run within 10 minutes in most cases. Setup
  • 9. Step 2 Pressure Coefficient Results ● To obtain pressure coefficients, the results need to be post processed ● The pressure results are normalised using the wind speed at the same height in the wind profile. ● Results can be queried by simply selecting points on the building.
  • 10. These pressure coefficients can be used for many different things including increasing the accuracy of thermal models. Step 3 Import Into Thermal Modelling Solution
  • 11. Setting up a simulation Pressure Coefficients on Building Facades for Building Simulation
  • 12. Define region Define wind rose Define pedestrian zones 1 3 2-Minute Setup It’s that simple. 1. Define region 2. Define wind rose 3. Define pedestrian zones How simple can it be? 2
  • 13. Step 1 ● Position and size the cylindrical region of interest ● Define which direction is North Define City Region
  • 14. Step 2 Define Wind Rose Location was searched by address and the wind data automatically imported from the connected database (Wind speed and direction).
  • 15. Step 3 ● Pedestrian region was set to be 1.5m from the floor. ● All terrain at pedestrian level was select to be offset. ● In more complex scenarios, terraces, balconies or planes at set heights can be used to record results. Define pedestrian region
  • 16. Doing this yourself ● This can of course all be done by you! ● The Example project setup is here ● The ParaView state is here This will allow you to create pressure coefficients to the eurocode wind profile, but can be modified to suit your needs. Useful Links
  • 17. ● All these wind directions are computed in parallel, a transient (real time wind) simulation takes less than 2 hours. ● Results are exported on the building surfaces. 8 Directions, At Once! Results
  • 18. ● Pressure coefficients on windward side are higher than 1 and on the leeward side, less than 1 as expected. ● A pattern is observed that on the windward face of the building the pressure coefficients are fairly uniform. ● On the next slide we will look at how this alters due to shielding. Wind Pressure Coefficients Results South facade h/H = 0.2 S Cp 0.18
  • 19. ● When the wind is coming from the south the pressure is mostly unaffected by the closely surrounding buildings. ● This is different when there is an easterly wind, the shielding from the nearby building on the windward side causes the pressure coefficient to drop at building height. Wind Pressure Coefficients Results
  • 20. Results at 0° for SW Direction Nearby Building
  • 21. When comparing to pressure coefficients obtained in building simulation models we see the following: ● Pressure higher up the building is much higher in comparison to standard methods used, where flow is much faster than expected for this wind profile due to upstream obstruction. ● Lower down, it is much less as surrounding buildings are actively obstructing the flow. ● Up to 100% difference in Cp values across the length and width of the building. ● Imagine the error which propagates through to calculating air flow rates, loads, comfort and more! Summary How will this impact on your: ○ Overheating assessments? ○ Fresh air rates? ○ Energy/Loads? ○ Compliance?

Notas del editor

  1. D
  2. D
  3. NK
  4. N
  5. N
  6. D
  7. D
  8. D
  9. D
  10. D
  11. D
  12. D
  13. D
  14. D
  15. D
  16. D
  17. D
  18. D
  19. NK