Major factors to be considered during air sampling
 Constituent or pollutant
 Sampling rate
 Sampling time
Types of air monitoring
 Personal sampling
 Undertaken within breathing zone of operative
 As close to mouth and nose as practicable (within 200 mm)
 Inlet to the sampling head shouldn't be obstructed
 Portable monitors
 Can be moved during sampling
 Stationary sampling
 Fixed during sampling
Air Quality Measurement
 Measurements of air quality generally fall into:
 Source sampling - Emission from a source is measured
 Ambient Air Quality - Measures the quality of air in a particular
place.
 Industrial Hygiene sampling - for testing the air quality inside of
factories and places of work
 Indoor sampling - to study the quality of air in living spaces
Types of measurement/sampling
 Active sampling
 Passive sampling
 Electrochemical methods
 Optical analyzers
Types of Ambient monitoring Stations
Station type Description
Pedestrian exposure station In congested areas, surrounded by buildings with many
pedestrians and average traffic flow > 10000 vehicles/day.
Downtown neighbor hood
exposure stations
In central business districts but not congested areas, and less
high rise buildings. The average traffic flow < 500 vehicles/day.
Eg. parks, landscapes areas etc.
Residential population exposure
station
In the residential or sub-urban areas but not in central business
districts. Should be more than 100 m away from any street.
Mesoscale stations At appropriate height to collect meteorological and air quality
data at upper elevation; main purpose to collect the trend of
data variations not human exposure.
Non-urban stations In remote non-urban areas with no traffic and industrial activity.
Mainly for background concentrations.
Location of all stations but mesoscale stations should be 0.5 m from curve
and 2.5 to 3.5 m above the ground. For mesoscale stations it could be at even
higher elevations.
Active sampling
 Pumped Sampling
 Analytes all physically pulled into the sampler using an air
sampling pump
 Concentrating the analytes on some sort of media (adsorbents,
or filters)
Passive sampling
 Diffusive sampling
 Analytes enter the sampler unassisted due to molecular diffusion.
 Unlike active sampling, passive samplers don’t require electricity.
 The adsorbed analytes can be desorbed off the adsorbent by
solvent or thermal desorption.
Particulate Matter Sampling
 Gravimetric based
 Light scattering based
Working principles of gravimetric PM samplers
 Samplers work on the principle of Inertia
 Sub classified into
Impactors
 Jet of aerosol impinge on flat plate.
 Particles larger than cut size slips across the streamline and impacts the plate
 Smaller particles follow the streamline
HighVolume Sampler
https://www.qld.gov.au/environment/pollution/monitoring/air-pollution/samplers
Cascade Impactor
Cyclone
 Jet of air impinges tangentially on inner surface
 Swirls downward in a cyclonic fashion and into a conical section
 Air reverses direction and spirals upward to exit at the upper end
 Particles larger than cut size deposits on inner of cylinder and
later collects in grit pot.
Working principles of gravimetric PM samplers
Respirable dust sampler
Light Scattering method
Aethalometer
Measurement of gases
Sulfur Dioxide
 UV Fluorescence
 Air sample drawn into a scrubber chamber and then on into an
irradiation chamber where it is exposed to UV light
 SO2 absorbs in 190-230nm
 The amount of fluorescent radiation is directly proportional to the
concentration of SO2
Sulfur Dioxide
SO2 + UV SO2*
SO2* SO2 + light
Oxides of Nitrogen
 Chemiluminescence
 Passing sample over a catalyst to convert NO2 to NO
 Suitable for ambient air containing NOx (NO and NO2) at levels
less than 1 mL/m3
 Reaction of NO with ozone in a dark enclosed chamber to
produce light
 Provided the ozone is present in excess the light output is
directly proportional to the concentration of NO
 NO + O3 NO2* + O2
 NO2* NO2 + h (light)
Measurement of gases
Ozone
 Either by chemiluminescence methods or direct reading UV
detectors.
 Chemiluminescence method-Sample drawn into a mixing
chamber mixed with a stream of Ethene - causes a
chemiluminescent reaction and the subsequent emitted light
at about 430nm
 Direct reading UV method - stream of gas in the sample is
drawn through a flow cell where it is irradiated with UV light
at 254nm
Measurement of gases
Carbon Monoxide
 Non-dispersive infra red devices
 Sample through a flow cell in the instrument where it is irradiated
with infrared radiation
Measurement of gases
Impingers are glass bubble tubes designed for the collection of
airborne particles into a liquid medium.
 When using an air sampler, a known volume of air bubbles is
pumped through the glass tube that contains a liquid specified
in the method.
 The liquid is then analyzed to determine airborne
concentrations.
Glass Impinger
Impingers
Pollutant Solution
SO2 Tetrachloromercurate
NO2 Arsenite
NH3 Sulfuric acid
H2S Cadmium hydroxide
Cl2 Methylorange

Más contenido relacionado

Similar a 1. AQ Part2.pdf

Environmental monitoring -I arup das2020
Environmental monitoring -I arup das2020Environmental monitoring -I arup das2020
Environmental monitoring -I arup das2020
Arup8
 

Similar a 1. AQ Part2.pdf (20)

Environmental monitoring -I arup das2020
Environmental monitoring -I arup das2020Environmental monitoring -I arup das2020
Environmental monitoring -I arup das2020
 
Ap ms oe_l3
Ap ms oe_l3Ap ms oe_l3
Ap ms oe_l3
 
Appropriate Instruments & techniques for Complying with Air Quality Standards
Appropriate Instruments & techniques for Complying with Air Quality StandardsAppropriate Instruments & techniques for Complying with Air Quality Standards
Appropriate Instruments & techniques for Complying with Air Quality Standards
 
Dr bhargava
Dr bhargavaDr bhargava
Dr bhargava
 
air Pollution sampling
air Pollution samplingair Pollution sampling
air Pollution sampling
 
Monitoring of Gaseous Pollutants
Monitoring of Gaseous PollutantsMonitoring of Gaseous Pollutants
Monitoring of Gaseous Pollutants
 
Gases
GasesGases
Gases
 
Particle deposition control
Particle deposition controlParticle deposition control
Particle deposition control
 
Odour Management 101 Wef2008
Odour Management 101 Wef2008Odour Management 101 Wef2008
Odour Management 101 Wef2008
 
A case study on Air Pollution in Cement Industry
A case study on Air Pollution in Cement IndustryA case study on Air Pollution in Cement Industry
A case study on Air Pollution in Cement Industry
 
airsamplingmethod-170601114240.pptx
airsamplingmethod-170601114240.pptxairsamplingmethod-170601114240.pptx
airsamplingmethod-170601114240.pptx
 
airsamplingmethod-170601114240.pptx
airsamplingmethod-170601114240.pptxairsamplingmethod-170601114240.pptx
airsamplingmethod-170601114240.pptx
 
Air sampling methods
Air sampling methodsAir sampling methods
Air sampling methods
 
Air quality sampling and monitoring m5
Air quality sampling and monitoring m5Air quality sampling and monitoring m5
Air quality sampling and monitoring m5
 
Air pollution measurement , emission estimates
Air pollution measurement , emission estimatesAir pollution measurement , emission estimates
Air pollution measurement , emission estimates
 
L 35 final
L 35 finalL 35 final
L 35 final
 
Air bacteriology
Air bacteriologyAir bacteriology
Air bacteriology
 
Air Sampling.pptx
Air Sampling.pptxAir Sampling.pptx
Air Sampling.pptx
 
Environmental practicals - EM.pdf
Environmental practicals - EM.pdfEnvironmental practicals - EM.pdf
Environmental practicals - EM.pdf
 
11 occupational hygiene monitoring of dust
11 occupational hygiene monitoring of dust11 occupational hygiene monitoring of dust
11 occupational hygiene monitoring of dust
 

Último

Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 

Último (20)

Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Double Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torqueDouble Revolving field theory-how the rotor develops torque
Double Revolving field theory-how the rotor develops torque
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
 
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
Hostel management system project report..pdf
Hostel management system project report..pdfHostel management system project report..pdf
Hostel management system project report..pdf
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 

1. AQ Part2.pdf

  • 1. Major factors to be considered during air sampling  Constituent or pollutant  Sampling rate  Sampling time
  • 2. Types of air monitoring  Personal sampling  Undertaken within breathing zone of operative  As close to mouth and nose as practicable (within 200 mm)  Inlet to the sampling head shouldn't be obstructed  Portable monitors  Can be moved during sampling  Stationary sampling  Fixed during sampling
  • 3. Air Quality Measurement  Measurements of air quality generally fall into:  Source sampling - Emission from a source is measured  Ambient Air Quality - Measures the quality of air in a particular place.  Industrial Hygiene sampling - for testing the air quality inside of factories and places of work  Indoor sampling - to study the quality of air in living spaces
  • 4. Types of measurement/sampling  Active sampling  Passive sampling  Electrochemical methods  Optical analyzers
  • 5. Types of Ambient monitoring Stations Station type Description Pedestrian exposure station In congested areas, surrounded by buildings with many pedestrians and average traffic flow > 10000 vehicles/day. Downtown neighbor hood exposure stations In central business districts but not congested areas, and less high rise buildings. The average traffic flow < 500 vehicles/day. Eg. parks, landscapes areas etc. Residential population exposure station In the residential or sub-urban areas but not in central business districts. Should be more than 100 m away from any street. Mesoscale stations At appropriate height to collect meteorological and air quality data at upper elevation; main purpose to collect the trend of data variations not human exposure. Non-urban stations In remote non-urban areas with no traffic and industrial activity. Mainly for background concentrations. Location of all stations but mesoscale stations should be 0.5 m from curve and 2.5 to 3.5 m above the ground. For mesoscale stations it could be at even higher elevations.
  • 6. Active sampling  Pumped Sampling  Analytes all physically pulled into the sampler using an air sampling pump  Concentrating the analytes on some sort of media (adsorbents, or filters)
  • 7. Passive sampling  Diffusive sampling  Analytes enter the sampler unassisted due to molecular diffusion.  Unlike active sampling, passive samplers don’t require electricity.  The adsorbed analytes can be desorbed off the adsorbent by solvent or thermal desorption.
  • 8. Particulate Matter Sampling  Gravimetric based  Light scattering based
  • 9. Working principles of gravimetric PM samplers  Samplers work on the principle of Inertia  Sub classified into Impactors  Jet of aerosol impinge on flat plate.  Particles larger than cut size slips across the streamline and impacts the plate  Smaller particles follow the streamline
  • 12. Cyclone  Jet of air impinges tangentially on inner surface  Swirls downward in a cyclonic fashion and into a conical section  Air reverses direction and spirals upward to exit at the upper end  Particles larger than cut size deposits on inner of cylinder and later collects in grit pot. Working principles of gravimetric PM samplers
  • 15. Measurement of gases Sulfur Dioxide  UV Fluorescence  Air sample drawn into a scrubber chamber and then on into an irradiation chamber where it is exposed to UV light  SO2 absorbs in 190-230nm  The amount of fluorescent radiation is directly proportional to the concentration of SO2
  • 16. Sulfur Dioxide SO2 + UV SO2* SO2* SO2 + light
  • 17. Oxides of Nitrogen  Chemiluminescence  Passing sample over a catalyst to convert NO2 to NO  Suitable for ambient air containing NOx (NO and NO2) at levels less than 1 mL/m3  Reaction of NO with ozone in a dark enclosed chamber to produce light  Provided the ozone is present in excess the light output is directly proportional to the concentration of NO  NO + O3 NO2* + O2  NO2* NO2 + h (light) Measurement of gases
  • 18. Ozone  Either by chemiluminescence methods or direct reading UV detectors.  Chemiluminescence method-Sample drawn into a mixing chamber mixed with a stream of Ethene - causes a chemiluminescent reaction and the subsequent emitted light at about 430nm  Direct reading UV method - stream of gas in the sample is drawn through a flow cell where it is irradiated with UV light at 254nm Measurement of gases
  • 19. Carbon Monoxide  Non-dispersive infra red devices  Sample through a flow cell in the instrument where it is irradiated with infrared radiation Measurement of gases
  • 20. Impingers are glass bubble tubes designed for the collection of airborne particles into a liquid medium.  When using an air sampler, a known volume of air bubbles is pumped through the glass tube that contains a liquid specified in the method.  The liquid is then analyzed to determine airborne concentrations. Glass Impinger Impingers Pollutant Solution SO2 Tetrachloromercurate NO2 Arsenite NH3 Sulfuric acid H2S Cadmium hydroxide Cl2 Methylorange