SECTION - 1L
Incandescent Lighting Fixture
SECTION 1L
Incandescent Lighting Fixtures INDEX
Model
Lamp Type / Watt. Certification for Explosion-proof
PAGEIncandescent lamp
IEC UL
20 60 100 150 200 300
VDY ● ● 1L - 1
SYL ● ● Ex e II T1 1L - 4
EML ● ● Ex d IIB T3 1L - 7
EUL ● ● Ex d IIB T3 1L - 9
EULS ●
Ex d IIB T4
Ex DP II 12 IP55
1L - 12
EFL ● ● ●
Ex d IIC T3
Ex d IIC T5
Class I Division 1,2
Group C,D
1L - 15
POLE TYPE Flameproof, Increased Safety, Vaportight Type Pole 1L -19
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
VDY Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VDY Series lighting fixtures are used ;
in manufacturing plants,
refineries, chemical,
petrochemical and other industrial
process facilities, wastewater and
sewage treatment plants,
offshore, dockside and other
harbor installations as well as
other heavy industrial
applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in Industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screw neck globe and the
guard are screwed on to the
body applying the reflector in its
position by the guard.
Synthetic rubber gasket is used
between the body and globe, so
that the lamp housing is sealed
against vapors and dusts.
Relamping is easily done by
opening lower half of the guard
and unscrewing the globe.
H.I.D lighting fixture has external
type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating
aluminium
Mounting Box : Cast aluminium
alloy
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
< VDY >
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance Technical Data
IP55 Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V/ DC110V
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Ceiling (Small) VDY 2105 2.2 kg
Ceiling (Large) VDY 2205 4.5 kg
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket
Incandescent
Lamp
100
1/2" VDY 1105 VDY 2105 VDY 3105 VDY 4105
3/4" VDY 1103 VDY 2103 VDY 3103 VDY 4103
200
1/2" VDY 1205 VDY 2205 VDY 3205 VDY 4205
3/4" VDY 1203 VDY 2203 VDY 3203 VDY 4203
Ordering Information
V D Y 1 1 0 5
① ② ③ ④
VDY Lighting Fixture① : Mounting Type② : Lamp Wattage (W)③ : Entry Size④
1 - Pendant 10 - 100 1 - 1"
2 - Ceiling 20 - 200 3 - 3/4"
3 - 90° Bracket 5 - 1/2"
4 - 40° Bracket
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VDY 2105> 0 145 50 130
5 135 55 115Lamp : IL100 (1250 lm)+
With Globe and Guard+
Reflector :+
White Coating Aluminum
Reflector
10 150 60 95.0
15 180 65 80.0
20 150 70 90.0
25 140 75 25.0
30 160 80 15.0
35 145 85 5.0
40 130 90 0.0
45 135
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .64 .64 .64 .63 .63 .63 .60 .60 .60 .57 .57 .57 .55 .55 .55 .54
1 .57 .55 .54 .56 .54 .53 .54 .52 .51 .52 .51 .50 .50 .49 .48 .47
2 .52 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .45 .44 .42 .41
3 .46 .43 .40 .46 .42 .39 .44 .41 .39 .43 .40 .38 .41 .39 .38 .36
4 .42 .38 .35 .41 .38 .35 .40 .37 .34 .39 .36 .34 .38 .35 .33 .32
5 .38 .34 .31 .38 .34 .31 .37 .33 .30 .36 .33 .30 .35 .32 .30 .29
6 .35 .31 .28 .34 .30 .28 .34 .30 .27 .33 .30 .27 .32 .29 .27 .26
7 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .25 .29 .27 .24 .23
8 .30 .26 .23 .29 .25 .23 .29 .25 .23 .28 .25 .22 .27 .24 .22 .21
9 .28 .24 .21 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .20
10 .26 .22 .19 .25 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .18
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Pendant Type > < VDY 90° Bracket Type >
< VDY Ceiling Type > < VDY 40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
SYL Series
Wet Locations
NEMA 3, 3R, 4, 7
Type of Explosion-proof
< SYL >
Increase Safety (Ex e II T1)
Application
SYL Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with
synthetic rubber gaskets, and
the globe assembly is fitted to
the body by three socket head
captive screws.
All joint of lamp housing,
including the joint between the
top body and the terminal
plate, are sealed up with high
quality gaskets so as to restrict
breathing.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting aluminium
Mounting Box : Cast aluminium alloy
External Hardware :
Stainless steel
Compliance Standard Finish
NEMA 3 ,3R, 4, 7
IEC 60079-0, 1
IP55
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us
please.
Technical Data
WeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V/ DC110V Mounting Type Catalog No. Weight
Rated Wattage 100W/ 200W
Ceiling SYL 2105 3.9 Kg
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<SYL 2205> 0 137.0 50 132.7
5 143.4 55 149.8
Lamp : IL200 (2920 lm)+
With Globe and Guard+ 10 149.8 60 102.7
15 128.4 65 98.5
20 134.9 70 34.2
25 137.0 75 15.0
30 107.0 80 6.4
35 107.0 85 4.3
40 102.7 90 2.2
45 111.3
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .62 .62 .62 .60 .60 .60 .58 .58 .58 .55 .55 .55 .53 .53 .53 .52
1 .55 .53 .51 .54 .52 .51 .52 .50 .49 .50 .49 .47 .48 .47 .46 .45
2 .49 .46 .44 .48 .45 .43 .46 .44 .42 .45 .43 .41 .43 .42 .40 .39
3 .44 .40 .37 .43 .40 .37 .42 .39 .36 .40 .38 .36 .39 .37 .35 .34
4 .40 .35 .32 .39 .35 .32 .38 .34 .32 .36 .34 .31 .35 .33 .31 .30
5 .36 .31 .28 .35 .31 .28 .34 .31 .28 .33 .30 .28 .32 .29 .27 .26
6 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .24 .29 .26 .24 .23
7 .29 .25 .22 .29 .25 .22 .28 .25 .22 .28 .24 .22 .27 .24 .22 .21
8 .27 .23 .20 .27 .23 .20 .26 .22 .20 .25 .22 .20 .25 .22 .20 .19
9 .25 .21 .18 .25 .21 .18 .24 .21 .18 .23 .20 .18 .23 .20 .18 .17
10 .23 .19 .17 .23 .19 .17 .22 .19 .17 .22 .19 .16 .21 .18 .16 .16
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling 90° Bracket 40° Bracket Certification
Incandescent
Lamp
100
1/2" SYL 1105 SYL 2105 SYL 3105 SYL 4105
Ex e II T1
3/4" SYL 1103 SYL 2103 SYL 3103 SYL 4103
200
1/2" SYL 1205 SYL 2205 SYL 3205 SYL 4205
3/4" SYL 1203 SYL 2203 SYL 3203 SYL 4203
Ordering Information
S Y L 1 1 0 5
① ② ③ ④
SYL Lighting Fixture① ② Mounting Type Lamp Wattage (W)③ Entry Size④
1 - Pendant 10 - 100 1 - 1"
2 - Ceiling 20 - 200 3 - 3/4"
3 - 90° Bracket 5 - 1/2"
4 - 40° Bracket
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SYL Ceiling Type > < SYL Pendant Type >
< SYL 90° Bracket Type > < SYL 40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EML Series
Wet Locations
NEMA 3, 3R, 7
<EML 8024>
Type of Explosion-proof
Flameproof (Ex d IIB T3)
Application
EML Series incandescent lighting fixtures are used ;
for flush or surface mounting on ceiling, wall or
pedant in conduit systems.
in hazardous areas, both indoors and outdoors where
enclosed and gasketed fixtures are required.
in tunnels, building entrances and similar locations,
where moisture, dirt, chemicals, vibration or rough
usage are a problem.
where ignitable concentrations of flammable gases,
vapors, liquids or dusts can exist some of the time
under normal operating conditions.
Features
Designed to exclude dirt, moisture and corrosive
vapors from the interior of the fixtures and the
conduit system.
The globe-guard assembly in installed and removed
as a unit making it necessary to handle only one
piece in relamping.
All fixtures are rugged and corrosion-resistant.
Standard Materials
Enclosure : Cast aluminium alloy
Globe : Heat resistant hard glass
Globe Ring : Cast aluminium alloy
Guard : Stainless steel wire
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certification
Certified by KOSHA (Korea Occupational Safety &
Health Agency), KGS (Korea Gas Safety Corporation),
and the others.
Weight
Mounting Type Catalog No. Weight
Ceiling EML 8024 4.7 Kg
Standard Finish Technical Data
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Electrical Rating
Rated Voltage
AC110V/ 220V/ 240V
DC110V
Rated Wattage 100W/ 150W/ 200W/ 300W
Options
Entry Size 1/2", 3/4", 1"
Guard : Stainless steel
Reflector : Aluminium Dome Reflector
Aluminium 30° Angle Reflector
Pole type pendant
* Atmosphere Temp : -20 ~ 55℃ ℃
Ordering Number
Lamp Watt Pendant Ceiling Bracket Certification
Incandescent Lamp
100 EML 8011 EML 8021 EML 8031
Ex d IIB T3
150 EML 8014 EML 8024 EML 8034
200 EML 8012 EML 8022 EML 8032
300 EML 8013 EML 8023 EML 8033
* For Pole type, see pole section (1L-19)
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EML 8021> 0 75 50 130
5 76 55 132
Lamp : IL100 (1250 lm)+
With Globe and+
without Guard
10 80 60 139
15 88 65 143
20 92 70 147
25 101 75 151
30 111 80 150
35 118 85 150
40 126 90 150
45 129
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .88 .88 .88 .86 .86 .86 .82 .82 .82 .78 .78 .78 .75 .75 .75 .74
1 .74 .70 .66 .72 .68 .65 .69 .66 .63 .66 .63 .61 .63 .61 .59 .57
2 .62 .55 .50 .60 .54 .49 .57 .52 .48 .55 .51 .47 .52 .49 .46 .44
3 .52 .45 .39 .51 .44 .39 .49 .43 .38 .47 .42 .37 .45 .40 .37 .35
4 .45 .38 .32 .44 .37 .32 .42 .36 .31 .40 .35 .31 .39 .34 .30 .28
5 .40 .32 .27 .39 .32 .26 .37 .31 .26 .36 .30 .26 .34 .29 .25 .24
6 .35 .28 .23 .35 .28 .23 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20
7 .32 .25 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .17
8 .29 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .26 .21 .17 .15
9 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .24 .19 .15 .14
10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
Dimension
<EML Ceiling Type> < EML Pendant Type > < EML Bracket Type>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EUL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T3)
<EUL 3021>
Features
The body is cast in one piece,
and the upper part of which
forms a terminal chamber.
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
The globe holder is fixed to the
base of the body with special
flameproof and weatherproof
flanged joint.
The guard is so constructed that
can be hinged down for
cleaning the globe.
Application
EUL Series lighting fixtures are used ;
in tunnels, building entrances and
similar locations where moisture,
dirt, chemicals or rough usage are
a problem.
in heavy process industries having
environments where flammable or
explosive vapors or gases, or where
combustible dusts are present.
in areas where combustible dusts
and flammable vapors are present
simultaneously.
in hazardous areas, both indoors
and
outdoors where long life and low
maintenance costs are desired.
where high light output is needed
but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids or
dusts can exist some of the time
under normal operating conditions.
Compliance
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Standard Materials Standard Finish
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EUL 3022 3.7 ㎏
Rated Wattage 100W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
Incandescent Lamp
100 EUL 3011 EUL 3021 EUL 3031 EUL 3041
Ex d IIB T3
200 EUL 3012 EUL 3022 EUL 3032 EUL 3042
* For Pole type, see pole section (1L-19)
Ordering Information Temperature Performance Data
E U L 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition
① ② ③ Type Watt. Temp ( )℃ "d" "DP"
EUL Lighting Fixture① Mounting Type②
Incandescent
100
40 T4 11
1 - Pendant 55 T3 -
Wattage (W)③ 2 - Ceiling
200
40 T4 11
1 - 100 3 - 90° Bracket 55 T3 -
2 - 200 4 - 40° Bracket
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUL 3021> 0 167 50 133
5 180 55 132
Lamp : IL100 (1250lm)+
With Guard+ 10 138 60 158
15 140 65 119
20 136 70 120
25 146 75 107
30 175 80 91.8
35 171 85 27.7
40 162 90 10.1
45 153
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .87 .87 .87 .85 .85 .85 .81 .81 .81 .78 .78 .78 .75 .75 .75 .73
1 .76 .73 .70 .74 .71 .69 .71 .69 .67 .68 .66 .65 .66 .64 .63 .61
2 .67 .62 .57 .65 .61 .57 .63 .59 .55 .60 .57 .54 .58 .55 .53 .51
3 .59 .53 .48 .57 .52 .47 .55 .50 .47 .53 .49 .46 .51 .48 .45 .43
4 .52 .46 .41 .51 .45 .40 .49 .44 .40 .47 .43 .39 .46 .42 .39 .37
5 .46 .40 .35 .46 .39 .35 .44 .39 .35 .43 .38 .34 .41 .37 .34 .32
6 .42 .35 .31 .41 .35 .31 .40 .34 .30 .39 .34 .30 .38 .33 .30 .28
7 .38 .32 .27 .38 .32 .27 .36 .31 .27 .35 .30 .27 .34 .30 .27 .25
8 .35 .29 .25 .34 .29 .24 .33 .28 .24 .33 .28 .24 .32 .27 .24 .23
9 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .21
10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUL 3022> 0 172 50 83.8
5 157 55 85.3Lamp : IL200 (2920lm)+
With Guard+ 10 166 60 70.7
15 152 65 82.1
20 138 70 92.5
25 143 75 84.6
30 127 80 78.3
35 103 85 79.2
40 92.5 90 95.4
45 87.9
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59
1 .60 .57 .54 .59 .56 .54 .56 .54 .52 .54 .52 .50 .52 .50 .49 .47
2 .52 .47 .43 .50 .46 .43 .48 .45 .42 .46 .43 .41 .44 .42 .40 .38
3 .45 .40 .36 .44 .39 .35 .42 .38 .35 .41 .37 .34 .39 .36 .33 .32
4 .40 .34 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .35 .32 .29 .27
5 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .32 .28 .25 .24
6 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .23 .21
7 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19
8 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .25 .21 .19 .18
9 .26 .21 .18 .25 .21 .17 .25 .20 .17 .24 .20 .17 .23 .20 .17 .16
10 .24 .19 .16 .24 .19 .16 .23 .19 .16 .23 .19 .16 .22 .19 .16 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent / Compact Fluorescent
Lighting Fixtures
EULS Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12 IP55)
Application Features
EULS Series lighting fixtures are used ;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible
dusts and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
< EULS >
Globe assembly is securely
hinged to the body.
Mounting box has four-way
conduit entries and a large
access opening cover for wiring.
Standard Materials
Enclosure :
Die casting aluminium
Globe :
Heat resistant hard glass
Inner Reflector :
High purity aluminium
External Hardware :
Stainless steel
Mounting Box : Cast aluminium
alloy
Compliance & Certification Standard Finish
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
IEC 60079- 0.1
NENA 3.3R.7
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EULS 3021 2.8 ㎏
Rated Wattage IL 100W/ CFL 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling
90°
Bracket
40°
Bracket
Certification
Incandescent Lamp 100 EULS 3021 Ex d IIB T4
Compact Self Ballast Fluorescent Lamp 20 EULS 3022 Ex DP II 12
* Pendant , 90° and 40° Bracket types are order-made items.
Ordering Information Temperature Performance Data
E U L S 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition
① ② ③ ④ Type Watt. Temp ( )℃ "d" "DP"
, EULS Lighting Fixture① ② Watt④
Incandescent 100
40 T4 -
0 - 20 55 - -
Mounting Type③ 1 - 100 Compact
Fluorescent
20
40 T5 12
1 - Pendant 55 - -
2 - Ceiling
3 - 90° Bracket
4 - 40° Bracket
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EULS 3021> 0 124 50 109
5 108 55 139Lamp : IL 100 (1250 )+ ㏐
With Globe and Guard+ 10 96.5 60 131
15 128 65 123
20 126 70 128
25 124 75 107
30 118 80 66.8
35 111 85 19.6
40 128 90 10.8
45 124
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity
Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .77 .77 .77 .76 .76 .76 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65
1 .68 .65 .63 .66 .64 .62 .64 .61 .60 .61 .59 .58 .59 .57 .56 .55
2 .59 .55 .51 .58 .54 .50 .55 .52 .49 .53 .50 .48 .51 .49 .47 .45
3 .52 .46 .42 .51 .46 .42 .49 .44 .41 .47 .43 .40 .45 .42 .39 .38
4 .45 .40 .35 .45 .39 .35 .43 .38 .34 .41 .37 .34 .40 .36 .34 .32
5 .40 .35 .30 .40 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28
6 .36 .30 .26 .36 .30 .26 .35 .30 .26 .33 .29 .26 .32 .28 .25 .24
7 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .22 .21
8 .30 .24 .21 .30 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19
9 .28 .22 .19 .27 .22 .18 .26 .22 .18 .26 .21 .18 .25 .21 .18 .17
10 .26 .20 .17 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Angle cd/1000 lm Angle cd/1000 lm
<EULS 3022> 0 47.8 50 94.2
5 48.5 55 97.7
Lamp : CFL20 (1200 )+ ㏐
With Globe and Guard+ 10 49.3 60 99.9
15 51.3 65 101
20 56.3 70 102
25 61.8 75 101
30 70.3 80 98.4
35 78.0 85 94.2
40 83.7 90 90.7
45 89.4
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .57 .57 .57 .56
1 .56 .54 .51 .55 .52 .50 .53 .50 .48 .50 .49 .47 .48 .47 .45 .44
2 .47 .43 .39 .46 .42 .38 .44 .40 .37 .42 .39 .36 .40 .38 .35 .34
3 .40 .35 .30 .39 .34 .30 .37 .33 .29 .36 .32 .29 .34 .31 .28 .27
4 .35 .29 .24 .34 .29 .24 .32 .28 .24 .31 .27 .24 .30 .26 .23 .22
5 .30 .25 .20 .30 .24 .20 .29 .24 .20 .27 .23 .20 .26 .22 .19 .18
6 .27 .21 .17 .27 .21 .17 .25 .21 .17 .24 .20 .17 .23 .20 .17 .15
7 .24 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .21 .17 .14 .13
8 .22 .17 .13 .22 .17 .13 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12
9 .20 .15 .12 .20 .15 .12 .19 .15 .11 .18 .14 .11 .18 14 .11 .10
10 .18 .14 .10 .18 .13 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09
Dimension
< Ceiling Type>
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Class I Division 1,2 Group C,D
Flameproof (Ex d IIC T3)
Features
Application
<EFL 6021>
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of
flammable vapors or gases and
where dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.
Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Certification Compliance
UL Listed File No. E 131747
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
NEC - Class I Division 1,2 Group C,D,
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. 240V (120V/ 220V for UL Listed) Pendant EFL 6011 5.3 ㎏
Rated Wattage 100W/ 200W/ 300W Ceiling EFL 6021 5.2 ㎏
Rated Frequency 50Hz/ 60Hz Bulkhead EFL 6043 7.3 ㎏
Entry Size 1/2", 3/4", 1" Bracket EFL 6033 8.1 ㎏
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Incandescent
100 EFL 6011 EFL 6021 EFL 6031 EFL 6041
Class I Division 1,2 Group C,D
Ex d IIC T3
200 EFL 6012 EFL 6022 EFL 6032 EFL 6042
300 EFL 6013 EFL 6023 EFL 6033 EFL 6043
If you need more information, contact us please⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Information Temperature Performance Data
E F L 6 0 1 1 Lamp Ambient Class I Flameproof
① ② ③ ④ Type Watt. Temp ( )℃ Group C,D "d"
Incandes
cent
100
40 120 (T4A) T3
EFL Lighting Fixture① Mounting Type③ Watt④ 55 - -
1 - Pendant 1 - 100
200
40 160(T3C) / 120(T4A)* T3
Lamp Type② 2 - Ceiling 2 - 200 55 - -
60 - Incandescent 3 - Bracket 3 - 300
300
40 160 (T3C) T3
4 - Bulkhead 55 - -
* are when use 300W body
Dimension
<Ceiling Type> <Bracket Type> <Bulkhead Type> <Pendant Type>
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EFL 6013> 0 124 50 86.8
5 118 55 92.7Lamp : IL300 (4278 lm)+
With Guard+ 10 112 60 94.6
15 108 65 98.6
20 96.7 70 104
25 90.7 75 86.8
30 80.9 80 82.9
35 74.9 85 80.9
40 73.0 90 78.8
45 77.0
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .66 .66 .66 .64 .64 .64 .61 .61 .61 .59 .59 .59 .56 .56 .56 .55
1 .56 .53 .50 .54 .52 .49 .52 .50 .48 .50 .48 .46 .48 .46 .45 .44
2 .47 .43 .39 .46 .42 .38 .44 .41 .38 .42 .39 .37 .40 .38 .36 .34
3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .36 .33 .30 .35 .32 .29 .28
4 .35 .30 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .31 .27 .25 .23
5 .31 .26 .22 .31 .26 .22 .30 .25 .22 .28 .24 .21 .27 .24 .21 .20
6 .28 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .18 .17
7 .26 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .16 .23 .19 .16 .15
8 .23 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .17 .15 .14
9 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12
10 .20 .15 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .18 .15 .12 .11
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EFL Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIC T5)
<EFL 7014>
Features
Factory sealed - no external seal
required
Easy to assemble and relamping
Light weight
Corrosion resistant
Inner reflector eliminates upward
spill light
Use compact fluorescent lamp 20W
instead of incandescent lamp.
Application
EFL Series lighting fixtures are used ;
in locations which are hazardous
due to the presence of flammable
vapors or gases and where
dampness or corrosion are
present.
as pendant, ceiling, wall bracket
or bulkhead fixtures, indoor for
general area or room lighting and
outdoor for spot lighting.
Standard Materials
Enclosure :
Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector :
Extra pure aluminium
Guard : Die casting aluminium
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Certification Compliance
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS(Korea Gas Safety
Corporation), and the others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage Max. AC240V Pendant EFL 7014 5.3 ㎏
Rated Wattage Compact Fluorescent 20W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Ordering Number
Lamp Watt Pendant Ceiling Bracket Bulkhead Certification
Compact Fluorescent 20 EFL 7014 EFL 7024 EFL 7034 EFL 7044 Ex d IIC T5
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Information Temperature Performance Data
E F L 7 0 1 4 Lamp Ambient Flameproof
① ② ③ ④ Type Watt. Temp ( )℃ "d"
Compact
Fluorescent
20
40 T5
EFL Lighting Fixture① Mounting Type③ Watt : 4 - 20④ 55 -
1 - Pendant
Lamp Type② 2 - Ceiling
70 - Compact Fluorescent 3 - Bracket
4 - Bulkhead
Dimension
<Ceiling Type> <Bracket Type> <Bulkhead Type> <Pendant Type>
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 63.3 50 86.5<EFL 7014>
5 63.3 55 92.2
Lamp : CFL20 (1200 lm)+
With Guard+
10 64.0 60 98.4
15 65.3 65 101
20 71.8 70 104
25 78.7 75 108
30 80.2 80 104
35 78.0 85 99.9
40 76.7 90 92.9
45 80.2
▞Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .69 .69 .69 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58
1 .58 .55 .52 .57 .54 .51 .54 .52 .50 .52 .50 .48 .50 .48 .47 .45
2 .48 .44 .39 .47 .43 .39 .45 .41 .38 .43 .40 .37 .41 .39 .36 .35
3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .37 .33 .29 .35 .32 .29 .27
4 .36 .30 .25 .35 .29 .25 .33 .28 .25 .32 .28 .24 .30 .27 .24 .22
5 .31 .25 .21 .31 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19
6 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .24 .20 .17 .16
7 .25 .20 .16 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .14
8 .23 .17 .14 .22 .17 .14 .22 .17 .14 .21 .17 .13 .20 .16 .13 .12
9 .21 .16 .12 .21 .16 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .11
10 .19 .14 .11 .19 .14 .11 .18 .14 .11 .18 .14 .11 .17 .14 .11 .10
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Incandescent Lighting Fixtures Pole Type
Explosion proof & Vaportight
Weathertight
NEMA 3, 3R, 5
Lighting
Fixtures
Construction
Lamp
Watt
Catalog Number
Hand Rail Type Pedestal Type
2.5M Height 3.5M Height 2.5M Height 3.5M Height
EFLP Series
Flameproof
Ex d IIB T3
CL I,
GR C,D
60 EFLP 60906-25H EFLP 60906-35H EFLP 60906-25P EFLP 60906-35P
100 EFLP 60910-25H EFLP 60910-25H EFLP 60910-25H EFLP 60910-35H
200 EFLP 60920-25H EFLP 60920-25H EFLP 60920-25H EFLP 60920-35H
EULP Series
Flameproof
Ex d IIB T4
60 EULP 30906-25H EULP 30906-35H EULP 30906-25P EULP 30906-35P
100 EULP 30910-25H EULP 30910-35H EULP 30910-25H EULP 30910-35H
200 EULP 30920-25H EULP 30920-35H EULP 30920-25H EULP 30920-35H
SYLP Series
Increased
Safety
Ex e II T1
60 SYLP 70906-25H SYLP 70906-35H SYLP 70906-25P SYLP 70906-35P
100 SYLP 70910-25H SYLP 70910-35H SYLP 70910-25P SYLP 70910-35P
200 SYLP 70920-25H SYLP 70920-35H SYLP 70920-25P SYLP 70920-35P
VDYP Series
Vapor Tight
IP 54
60 VDYP 10906-25H VDYP 10906-35H VDYP 10906-25P VDYP 10906-35P
100 VDYP 10910-25H VDYP 10910-35H VDYP 10910-25P VDYP 10910-35P
200 VDYP 10920-25H VDYP 10920-35H VDYP 10920-25P VDYP 10920-35P
Features
These pole type fittings are the combinations of lighting units for Flameproof EFLP, EULP series, Increase safety
SYLP series or Vapor tight VDYP series incandescent lighting fittings and goose neck shaped poles.
These fittings are mainly used for tower illumination of chemical plant.
Additionally, fixing and wiring connection of these fittings are recommended to be done with Flameproof EOB or
Increased safety and Heavy duty SBD junction boxes in compliance with the type of protection of lighting units.
Other height not listed in the catalog are also available on request.
Conduit entry-Three(3)-28(1")max. Specify the position and size when ordering.
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< Hand Rail Type >
* Length (L) is order made.
(Standard is 2.5M, 3.5M. See front page)
< Pedestal Type >
SECTION - 2L
HID Lighting Fixture
SECTION 2L
H.I.D Lighting Fixtures INDEX
Model
Lamp Type / Watt.
Certification for Explosion-proof
PAGEHigh Pressure Sodium Mercury Vapor Metal Halide
50 70 100 150 200 250 400 100 200 250 400 100 175 250 400 IEC UL
VD ● ● ● ● ● ● ● ● 2L - 1
VS ● ● ● ● ● ● ● ● ● ● ● ● ● 2L - 4
SR ● ● ● ● ● ● ● ● ● ● ● ● ● Ex nR II T3 2L - 7
VG ● ● ● ● ●
Ex nR II T4 IP66
Ex DP II 11
Class I
Division 2
Group A,B,C,D
Class II
Division 1,2
Group E,F,G
Class III
Division 1
2L - 12
VN ● ● ● ● ● ● ● 2L - 15
VZ ● ● ● ● ● ● 2L - 19
AUXILIARY H.I.D AUXILIARY LIGHTING 2L - 23
EVN ● ● ● ● ● ● ●
Ex dnR IIC T4
Ex nR II T4 IP66
Ex DP II 11 IP66
2L - 24
EU ● ● ● ● ●
Ex d IIB T4
Ex DP II 12
2L - 30
EA ● ● ● ● ● ● ●
Ex d IIC T4
Ex d IIB T4
2L - 33
EVS ● ● ● ● ● ● ● ● ● ● Ex de IIC T3 2L - 39
EGS ● ● ● ● ●
Ex d IIC T4
Ex DP II 12
2L - 43
EG ● ● ● ● ● ● ● ● ● ● Ex d IIC T3
Class I Division
1 Group C,D
2L - 46
POLE TYPE Flameproof, Increased Safety, Vaportight Pole Type 2L - 51
SB HID Ballast 2L - 53
Accessary Globe, Guard, Reflector 2L - 55
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VD Series
Weathertight
NEMA 3, 3R, 5
Application Features Standard Materials
VD Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and
other industrial process facilities,
wastewater and sewage
treatment plants, offshore,
dockside and other harbor
installations as well as other heavy
industrial applications.
wherever the damaging effects of
wind, snow, sleet, or hot sun are
found.
in marine applications where
water spray and corrosive
atmospheres are considerations.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
in Industrial areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in industrial locations requiring
elevated ambient capability.
The lighting fixture has simple
construction.
The screwneck globe and the
guard are screwed on to the
body applying the reflector in
its position by the guard.
Synthetic rubber gasket is
used between the body and
globe, so that the lamp
housing is sealed against
vapors and dusts.
Relamping is easily done by
opening lower half of the
guard and unscrewing the
globe.
H.I.D lighting fixture has
external type ballast.
Body : Die casting aluminium
Globe : Heat resistant hard glass
Reflector : White coating aluminium
Mounting Box : Cast aluminium
alloy
Certification
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IP55
< VD >
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Technical Data Weight
Electrical Ratings Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling (Small) VDNY 32075 8.7 Kg
Ceiling (Large) VDNY 32155 15.5 KgRated Wattage 70W/ 100W/ 150W/ 175W/ 200W
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket
High
Pressure
Sodium
70
1/2" VDNY 31075 VDNY 32075 VDNY 33075 VDNY 34075
3/4" VDNY 31073 VDNY 32073 VDNY 33073 VDNY 34073
100
1/2" VDNY 31105 VDNY 32105 VDNY 33105 VDNY 34105
3/4" VDNY 31103 VDNY 32103 VDNY 33103 VDNY 34103
150
1/2" VDNY 31155 VDNY 32155 VDNY 33155 VDNY 34155
3/4" VDNY 31153 VDNY 32153 VDNY 33153 VDNY 34153
200
1/2" VDNY 31205 VDNY 32205 VDNY 33205 VDNY 34205
3/4" VDNY 31203 VDNY 32203 VDNY 33203 VDNY 34203
Metal
Halide
100
1/2" VDHY 31105 VDHY 32105 VDHY 33105 VDHY 34105
3/4" VDHY 31103 VDHY 32103 VDHY 33103 VDHY 34103
175
1/2" VDHY 31175 VDHY 32175 VDHY 33175 VDHY 34175
3/4" VDHY 31173 VDHY 32173 VDHY 33173 VDHY 34173
Mercury
Vapor
100
1/2" VDMY 31105 VDMY 32105 VDMY 33105 VDMY 34105
3/4" VDMY 31103 VDMY 32103 VDMY 33103 VDMY 34103
200
1/2" VDMY 31205 VDMY 32205 VDMY 33205 VDMY 34205
3/4" VDMY 31203 VDMY 32203 VDMY 33203 VDMY 34203
* For Pole type, see pole section (2L-51)
Ordering Information
V D N Y 3 1 0 7 5
① ② ③ ④ ⑤
VDY Lighting Fixture① Mounting Type③ Lamp Wattage (W)④ Entry Size⑤
31 - Pendant 07 - 70 1 - 1"
Lamp Type② 32 - Ceiling 10 - 100 3 - 3/4"
NY - High Pressure Sodium 33 - 90° Bracket 15 - 150 5 - 1/2"
HY - Metal Halide 34 - 40° Bracket 17 - 175
MY - Mercury Vapour 20 - 200
▞ Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VDNY 32105> 0 160 50 132
5 132 55 132Lamp : NH100 (9000 lm)+
With Globe and Guard+
Reflector :+
White Coating Aluminum
Reflector
10 132 60 132
15 146 65 125
20 160 70 125
25 153 75 111
30 146 80 83.3
35 139 85 27.8
40 139 90 6.9
45 132
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( ccρ )
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .84 .84 .84 .82 .82 .82 .78 .78 .78 .75 .75 .75 .72 .72 .72 .70
1 .73 .70 .68 .72 .69 .66 .69 .66 .64 .66 .64 .62 .63 .62 .61 .59
2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .55 .52 .56 .53 .51 .49
3 .56 .50 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .49 .46 .43 .41
4 .50 .43 .39 .49 .43 .38 .47 .42 .38 .45 .41 .37 .44 .40 .37 .35
5 .44 .38 .33 .44 .38 .33 .42 .37 .33 .41 .36 .32 .39 .35 .32 .31
6 .40 .34 .29 .39 .33 .29 .38 .33 .29 .37 .32 .28 .36 .32 .28 .27
7 .36 .30 .26 .36 .30 .26 .35 .29 .26 .34 .29 .25 .33 .28 .25 .24
8 .33 .27 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21
9 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .19
10 .28 .23 .19 .28 .23 .19 .27 .23 .19 .27 .22 .19 .26 .22 .19 .18
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VDY Ceiling Type > < VDY 40° Bracket Type >
< VDY Pendant Type > < VDY 90° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
VS Series
Wet Locations
NEMA 3, 3R
Application
< VS >
VS Series lighting fixtures are used ;
in manufacturing plants, refineries, chemical,
petrochemical and other industrial process
facilities, wastewater and sewage treatment plants,
offshore, dockside and other harbor installations
as well as other heavy industrial applications.
in industrial areas, both indoors and outdoors
where long life and low maintenance costs are
desired.
Features
The lighting fixture has simple construction.
Relamping is easily done by opening lower half of
the guard and unscrewing the globe.
H.I.D lighting fixture has external type ballast.
Standard Materials Technical Data
Body : Die casting aluminium
Globe : Heat resistant hard glass
External Hardware : Cast aluminium alloy
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Compliance Entry Size 1/2", 3/4", 1"
IP55
NEMA 3, 3R
Certification
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
Certified by KOSHA (Korea Occupational
Safety & Health Agency), KGS (Korea Gas
Safety Corporation), and the others.
Standard Finish Weight
Natural
If you want another color, contact us
please.
Catalog No. Weight
VSNL 7240 18.8 ㎏
Ordering Number Ordering Information
Lamp Watt Pendant Ceiling
90°
Bracket
40°
Bracket
V S N L 7 1 1 5
① ② ③ ④ ⑤
High
Pressure
Sodium
100 VSNL7110 VSNL7210 VSNL7310 VSNL7410 VS Lighting Fixture①
150 VSNL7115 VSNL7215 VSNL7315 VSNL7415
200 VSNL7120 VSNL7220 VSNL7320 VSNL7420 Lamp Type②
250 VSNL7125 VSNL7225 VSNL7325 VSNL7425 NL - High Pressure Sodium
400 VSNL7140 VSNL7240 VSNL7340 VSNL7440 HL - Metal Halide
Metal
Halide
100 VSHL7110 VSHL7210 VSHL7310 VSHL7410 ML - Mercury Vapour
175 VSHL7117 VSHL7217 VSHL7317 VSHL7417
250 VSHL7125 VSHL7225 VSHL7325 VSHL7425 Model Type③ Lamp Wattage (W)⑤
400 VSHL7140 VSHL7240 VSHL7340 VSHL7440 7 - VS Type 10 - 100
Mercury
Vapor
100 VSML7110 VSML7210 VSML7310 VSML7410 15 - 150
200 VSML7120 VSML7220 VSML7320 VSML7420 Mounting Type④ 17 - 175
250 VSML7125 VSML7225 VSML7325 VSML7425 1 - Pendant 20 - 200
300 VSML7130 VSML7230 VSML7330 VSML7430 2 - Ceiling 25 - 250
400 VSML7140 VSML7240 VSML7340 VSML7440 3 - 90° Bracket 30 - 300
* For Pole type, see pole section (2L-51) 4 - 40° Bracket 40 - 400
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VSHL 7217> 0 169.6 50 187.5
5 165.2 55 205.4Lamp : MH175 (14000 lm)+
With Globe and without Guard+ 10 169.6 60 147.3
15 209.8 65 84.8
20 223.2 70 44.6
25 205.4 75 26.8
30 205.4 80 13.4
35 192.0 85 4.5
40 200.9 90 4.5
45 209.8
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .90 .90 .90 .88 .88 .88 .84 .84 .84 .80 .80 .80 .77 .77 .77 .76
1 .81 .78 .76 .79 .77 .74 .76 .74 .72 .73 .71 .70 .70 .69 .68 .66
2 .73 .69 .65 .71 .68 .64 .69 .66 .63 .66 .64 .61 .64 .62 .60 .59
3 .66 .60 .56 .64 .60 .56 .62 .58 .55 .60 .57 .54 .59 .56 .53 .52
4 .59 .54 .49 .58 .53 .49 .57 .52 .48 .55 .51 .48 .53 .50 .47 .46
5 .54 .48 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .49 .45 .42 .41
6 .49 .43 .39 .48 .43 .39 .47 .42 .39 .46 .42 .38 .45 .41 .38 .37
7 .45 .39 .35 .45 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .33
8 .42 .36 .32 .41 .36 .32 .40 .35 .32 .39 .35 .31 .38 .34 .31 .30
9 .38 .33 .29 .38 .33 .29 .37 .32 .29 .36 .32 .29 .36 .32 .29 .27
10 .36 .30 .27 .35 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25
Angle cd/1000 lm Angle cd/1000 lm
<VSNL 7225> 0 302 50 158
5 288 55 155
Lamp : NH250 (25000 lm)+
With Globe and without+
Guard
10 235 60 142
15 210 65 108
20 182 70 72.5
25 162 75 47.5
30 165 80 27.5
35 160 85 15.0
40 152 90 7.5
45 155
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling Cavity
Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .83 .83 .83 .81 .81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .70
1 .73 .70 .67 .71 .69 .66 .68 .66 .64 .66 .64 .62 .63 .62 .60 .59
2 .65 .60 .57 .64 .60 .56 .61 .58 .55 .59 .56 .54 .57 .55 .52 .51
3 .58 .53 .49 .57 .52 .48 .55 .51 .47 .53 .49 .47 .51 .48 .46 .44
4 .52 .46 .42 .51 .46 .42 .49 .45 .41 .48 .44 .41 .46 .43 .40 .39
5 .47 .41 .37 .46 .41 .37 .45 .40 .37 .44 .39 .36 .42 .39 .36 .34
6 .43 .37 .33 .42 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .31
7 .39 .34 .30 .39 .33 .30 .38 .33 .29 .37 .32 .29 .36 .32 .29 .28
8 .36 .31 .27 .36 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25
9 .34 .28 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .31 .27 .24 .23
10 .31 .26 .23 .31 .26 .23 .30 .26 .22 .30 .25 .22 .29 .25 .22 .21
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VS Ceiling Type > < VS 40° Bracket Type >
< VS Pendant Type > < VS 90° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
SR Series
Wet Locations
NEMA 3, 3R, 4, 4X, 7
Type of Explosion-proof
< SR >
Non Sparking (Ex nR II T3)
Application
SR Series lighting fixtures are used ;
in heavy process industries having environments
where flammable or explosive vapors or gases, or
where combustible dusts are present.
in hazardous areas, both indoors and outdoors where
long life and low maintenance costs are desired.
in petroleum refineries, chemical, petrochemical and
other heavy process industry facilities.
where ignitable concentrations of flammable gases,
vapors or liquids can exist all of the time or some of
the time under normal operation conditions.
Features Certification Standard Materials
The globe frame is cast in one
piece with guard.
The globe is sealed into the
globe frame firmly with synthetic
rubber gaskets, and the globe
assembly is fitted to the body by
three socket head captive
screws.
All joint of lamp housing,
including the joint between the
top body and the terminal plate,
are sealed up with high quality
gaskets so as to restrict
breathing.
The body and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Enclosure : Aluminium sheet
Globe : Heat resistant hard glass
Globe Frame : Die casting
aluminium alloy
Mounting Box : Cast aluminium
alloy
External Hardware : Stainless
steelCompliance
NEMA 3 ,3R, 4, 4X, 7
IEC 60079-0, 15
IP55
Standard Finish
Options
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
With Choke or Lead Peak type
Ballast
Technical Data
WeightElectrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Enclosure Type Catalog No. Weight
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Small (Ceiling) SRHL 2105 10.3 Kg
Entry Size 1/2", 3/4", 1" Middle (Ceiling) SRHL 2255 19.6 Kg
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
100
1/2" SRNL1105 SRNL2105 SRNL3105 SRNL4105
Ex nR II T3
3/4" SRNL1103 SRNL2103 SRNL3103 SRNL4103
150
1/2" SRNL1155 SRNL2155 SRNL3155 SRNL4155
3/4" SRNL1153 SRNL2153 SRNL3153 SRNL4153
200
1/2" SRNL1205 SRNL2205 SRNL3205 SRNL4205
3/4" SRNL1203 SRNL2203 SRNL3203 SRNL4203
250
1/2" SRNL1255 SRNL2255 SRNL3255 SRNL4255
3/4" SRNL1253 SRNL2253 SRNL3253 SRNL4253
400
1/2" SRNL1405 SRNL2405 SRNL3405 SRNL4405
3/4" SRNL1403 SRNL2403 SRNL3403 SRNL4403
Metal
Halide
100
1/2" SRHL1105 SRHL2105 SRHL3105 SRHL4105
3/4" SRHL1103 SRHL2103 SRHL3103 SRHL4103
175
1/2" SRHL1175 SRHL2175 SRHL3175 SRHL4175
3/4" SRHL1173 SRHL2173 SRHL3173 SRHL4173
250
1/2" SRHL1255 SRHL2255 SRHL3255 SRHL4255
3/4" SRHL1253 SRHL2253 SRHL3253 SRHL4253
400
1/2" SRHL1405 SRHL2405 SRHL3405 SRHL4405
3/4" SRHL1403 SRHL2403 SRHL3403 SRHL4403
Mercury
Vapor
100
1/2" SRML1105 SRML2105 SRML3105 SRML4105
3/4" SRML1103 SRML2103 SRML3103 SRML4103
200
1/2" SRML1205 SRML2205 SRML3205 SRML4205
3/4" SRML1203 SRML2203 SRML3203 SRML4203
250
1/2" SRML1255 SRML2255 SRML3255 SRML4255
3/4" SRML1253 SRML2253 SRML3253 SRML4253
400
1/2" SRML1405 SRML2405 SRML3405 SRML4405
3/4" SRML1403 SRML2403 SRML3403 SRML4403
* For Pole type, see pole section (2L-51)
Ordering Information
S R N L 1 1 0 5
① ② ③ ④ ⑤
SR Lighting Fixture① ③ Mounting Type Lamp Wattage (W)④ Entry Size⑤
1 - Pendant 10 - 100 1 - 1"
Lamp Type② 2 - Ceiling 15 - 150 3 - 3/4"
NL - High Pressure Sodium 3 - 90° Bracket 17 - 175 5 - 1/2"
HL - Metal Halide 4 - 40° Bracket 20 - 200
ML - Mercury Vapour 25 - 250
40 - 400
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<SRNL 2255> 0 170 50 130
5 118 55 102Lamp : NH250 (25000 lm)+
With Globe and Guard+ 10 128 60 80.0
15 152 65 50.0
20 175 70 25.0
25 170 75 12.5
30 158 80 7.5
35 148 85 5.0
40 145 90 2.5
45 142
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .59 .59 .59 .58 .58 .58 .55 .55 .55 .53 .53 .53 .51 .51 .51 .50
250 1 1 .53 .52 .50 .52 .51 .49 .50 .49 .48 .48 .47 .46 .46 .46 .45 .44
2 .48 .46 .43 .47 .45 .43 .46 .44 .42 .44 .42 .41 .43 .41 .40 .39
200 0.8 3 .44 .41 .38 .43 .40 .38 .42 .39 .37 .40 .38 .36 .39 .37 .36 .35
4 .40 .36 .34 .39 .36 .34 .38 .35 .33 .37 .35 .33 .36 .34 .32 .31
150 0.6 5 .37 .33 .30 .36 .33 .30 .35 .32 .30 .34 .32 .29 .33 .31 .29 .28
6 .34 .30 .27 .33 .30 .27 .32 .29 .27 .32 .29 .27 .31 .28 .27 .26
100 0.4 7 .31 .27 .25 .31 .27 .25 .30 .27 .25 .29 .26 .24 .29 .26 .24 .23
8 .29 .25 .23 .28 .25 .23 .28 .25 .22 .27 .24 .22 .27 .24 .22 .21
9 .27 .23 .21 .26 .23 .21 .26 .23 .21 .25 .23 .21 .25 .22 .21 .20
10 .25 .22 .19 .25 .21 .19 .24 .21 .19 .24 .21 .19 .23 .21 .19 .18
Angle cd/1000 lm Angle cd/1000 lm
<SRHL2255> 0 203 50 220
5 168 55 204Lamp : MH250 (20500 lm)+
With Globe and Guard+ 10 156 60 137
15 143 65 57.9
20 152 70 27.4
25 174 75 12.2
30 213 80 6.1
35 238 85 3.0
40 229 90 3.0
45 229
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .86 .86 .86 .84 .84 .84 .80 .80 .80 .77 .77 .77 .74 .74 .74 .72
250 1 1 .77 .75 .72 .76 .73 .71 .73 .71 .69 .70 .68 .67 .67 .66 .65 .64
2 .70 .66 .63 .69 .65 .62 .66 .63 .61 .64 .61 .59 .62 .60 .58 .57
175 0.68 3 .63 .58 .55 .62 .58 .54 .60 .56 .53 .58 .55 .52 .56 .54 .51 .50
4 .57 .52 .48 .56 .51 .48 .55 .50 .47 .53 .49 .46 .52 .48 .46 .45
5 .52 .46 .42 .51 .46 .42 .50 .45 .42 .48 .45 .41 .47 .44 .41 .40
6 .47 .42 .38 .47 .41 .38 .46 .41 .37 .44 .40 .37 .43 .40 .37 .35
7 .43 .38 .34 .43 .38 .34 .42 .37 .34 .41 .37 .33 .40 .36 .33 .32
8 .40 .34 .31 .39 .34 .31 .38 .34 .30 .38 .33 .30 .37 .33 .30 .29
9 .37 .31 .28 .36 .31 .28 .36 .31 .28 .35 .31 .27 .34 .30 .27 .26
10 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .32 .28 .25 .24
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< SR 90° Bracket Type > < SR 40° Bracket Type >
< SR Ceiling Type > < SR Pendant Type >
LAMP WATT
Ceiling Type Pendant Type 90° Bracket 40° Bracket
A BØ A BØ A BØ A BØ C
Max. 100W 550 275 310 275 420 275 650 275 345
Max. 250W 640 340 400 340 510 340 710 340 400
Max. 400W 695 385 455 385 565 385 750 385 430
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG, VN, VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
< VG > < VN > < VZ >
Type of Explosion-proof Fixture Wattage
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Simultaneous Presence (VN Series)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11)
Lamp V Series Wattage
Type VG VN VZ
HPS 50, 70, 100 150, 200, 250 250, 400
MH 100 175, 250 250, 400
MV 100 200, 250 250, 400
Application in hazardous locations requiring
elevated ambient capability.
in installations where moisture,
dirt, dust, vibration, corrosion
and rough usage are problems.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy construction
and epoxy powder finish provide
excellent resistant to corrosion.
V Series HID lighting fixtures are
used ;
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
in petroleum refineries, chemical,
petrochemical and other heavy
process industry facilities.
in paint spray booth suitability
provides efficient, economical
HID lighting for paint spray
areas.
where ignitable concentrations of
flammable gases, vapors or
liquids can exist all of the time
or some of the time under
normal operation conditions.
Features
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Dome and 30°angle reflectors
made of FRP material won't rust,
corrode, dent, chip or peel.
If you need more data, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VG Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7
Type of Explosion-proof
Non Sparking (Ex nR II T4 IP66)
Class I Division 2 Group A,B,C,D
Features Standard Materials
Compact, lightweight design is ideal for medium and
low mounting heights.
Cast aluminium alloy construction and epoxy powder
finish provide excellent resistant to corrosion.
Hubs with integral conduit stop and bushing to help
prevent damage to field wiring during installation.
Restricted Breathing Construction : zone 2 only
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket : Porcelain with screw shell
Reflector : High grade aluminium sheet
Guard : Die casting aluminium
Compliance & Certification
< VG >
NEC - Class I Division 2 Group A,B,C,D
UL 844 - Lighting Fixtures for Use in Hazardous
(Classified) Locations
UL Listed File No. E 131747
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7
Certified by UL (Underwriters Laboratories Inc.),
KOSHA (Korea Occupational Safety & Health
Agency), KGS (Korea Gas Safety Corporation), and
the others.
Options
With Dome Reflector or 30° Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and capacitors
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V Ceiling VGNL 22103 7.7 ㎏
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
50
1" VGNL 12051 VGNL 22051 VGNL 32051 VGNL 92051
Ex nR II T4 IP66
Class I Division 2
Group A,B,C,D
3/4" VGNL 12053 VGNL 22053 VGNL 32053 VGNL 92053
70
1" VGNL 12071 VGNL 22071 VGNL 32071 VGNL 92071
3/4" VGNL 12073 VGNL 22073 VGNL 32073 VGNL 92073
100
1" VGNL 12101 VGNL 22101 VGNL 32101 VGNL 92101
3/4" VGNL 12103 VGNL 22103 VGNL 32103 VGNL 92103
Metal
Halide
100
1" VGHL 12101 VGHL 22101 VGHL 32101 VGHL 92101
Ex nR II T3 IP66
Class I Division 2
Group A,B,C,D
3/4" VGHL 12103 VGHL 22103 VGHL 32103 VGHL 92103
Mercury
Vapor
100
1" VGML 12101 VGML 22101 VGML 32101 VGML 92101
3/4" VGML 12103 VGML 22103 VGML 32103 VGML 92103
Ordering Information Dimension
<Bracket Type>
<Stanchion Type>
<Ceiling Type> <Pendant Type>
V G N L 1 2 0 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VG Lighting Fixture① Lamp Wattage (W)⑤
05 - 50
Lamp Type② 07 - 70
NL - High Pressure Sodium 10 - 100
HL - Metal Halide
ML - Mercury Vapour
Mounting Type③ Entry Size⑥
1 - Pendant 1 - 1"
2 - Ceiling 3 - 3/4"
3 - Bracket 5 - 1/2"
9 - Stanchion
Input Voltage (V)④
1 - 120 Options⑦
2 - 220 DR - Dome Type Reflector
3 - 110 AR - Angle Type Reflector
4 - 208
5 - 277 IR - Instant Restrike
6 - 240 FU - Fused Type
7 - 230
Temperature Performance Data
Lamp Ambient Class I Non-Sparking
Type Watt. Temp ( )℃ Div. 2 "nR"
High
Pressure
Sodium
50
40 260 (T2B) T4
55 - T4
70
40 260 (T2B) T4
55 - T4
100
40 260 (T2B) T4
55 - T4
Metal
Halide
100
40 - T3
55 - T3
Mercury
Vapor
100
40 280 (T2A) T4
55 - T4
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VGNL 12101-DR> 0 78.7 50 262.4
5 77.8 55 239.1
Lamp : NH100 (9000 lm)+
With Guard+
Reflector :+
Aluminium Dome type
Reflector
10 79.7 60 199.7
15 88.2 65 169.7
20 111.5 70 158.5
25 135.9 75 113.4
30 157.5 80 65.6
35 189.4 85 23.5
40 218.4 90 13.1
45 248.4
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77
1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62
100 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50
3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41
70 0.5 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34
5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29
50 0.25 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25
7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22
8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19
9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17
10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16
Angle cd/1000 lm Angle cd/1000 lm
<VGHL 12101-DR> 0 90.9 50 199.9
5 90.9 55 164.8Lamp : MH100 (6500 lm)+
With Guard+
Reflector :+
Aluminium Dome type
Reflector
10 94.8 60 144.0
15 114.2 65 132.4
20 133.7 70 48.1
25 177.8 75 27.3
30 218.0 80 16.9
35 266.1 85 11.7
40 266.1 90 9.0
45 245.3
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80
1 .86 .83 .80 .84 .81 .79 .81 .78 .77 .77 .76 .74 .75 .73 .72 .70
2 .77 .72 .68 .75 .71 .67 .72 .69 .66 .70 .67 .64 .68 .65 .63 .61
3 .69 .63 .59 .67 .62 .58 .62 .61 .57 .63 .59 .56 .61 .58 .55 .54
4 .62 .56 .51 .61 .55 .50 .59 .54 .50 .57 .53 .49 .55 .52 .49 .47
5 .56 .49 .44 .55 .49 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .41
6 .50 .44 .39 .50 .44 .39 .48 .43 .39 .47 .42 .38 .46 .42 .38 .37
7 .46 .40 .35 .45 .39 .35 .44 .39 .35 .43 .38 .34 .42 .38 .34 .33
8 .42 .36 .31 .42 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .29
9 .39 .32 .28 .38 .32 .28 .37 .32 .28 .36 .32 .28 .36 .31 .28 .26
10 .36 .30 .26 .35 .30 .26 .35 .29 .26 .34 .29 .25 .33 .29 .25 .24
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VN Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
< VN >
Type of Explosion-proof
Non Sparking (Ex nR II T3 IP66)
Dust Ignition-proof (Ex DP II 11)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features
Compact, lightweight design is ideal for medium
and low mounting heights.
Wide range of light sources to meet specific
lighting needs - High Pressure Sodium (HPS):
150, 200 and 250W, Mercury Vapour (MV): 200
and 250W, Metal Halide (MH): 175 and 250W.
Restricted Breathing Construction : Zone 2 only
Standard Materials
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector : Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification Compliance Options
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
With Dome Reflector or 30°
Angle Reflector
Instant Restrike (HPS only)
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come
to full brightness immediately
(Non-hazardous location only)Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data Weight
Electrical Rating
Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V
(110V/ 120V/ 208V/ 220V/
240V/ 277V for UL Listed)
Pendant VNNL 12153 12.6 ㎏
Ceiling VNNL 22153 12.8 ㎏Rated Wattage 150W/ 175W/ 200W/ 250W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
150
1" VNNL 12151 VNNL 22151 VNNL 32151 VNNL 92151
Ex nR II T3 IP66
Ex DP II 11
3/4" VNNL 12153 VNNL 22153 VNNL 32153 VNNL 92153
200
1" VNNL 12201 VNNL 22201 VNNL 32201 VNNL 92201
3/4" VNNL 12203 VNNL 22203 VNNL 32203 VNNL 92203
250
1" VNNL 12251 VNNL 22251 VNNL 32251 VNNL 92251
3/4" VNNL 12253 VNNL 22253 VNNL 32253 VNNL 92253
Metal
Halide
175
1" VNHL 12171 VNHL 22171 VNHL 32171 VNHL 92171
Ex nR II T3 IP66
Ex DP II 12 IP66
3/4" VNHL 12173 VNHL 22173 VNHL 32173 VNHL 92173
250
1" VNHL 12251 VNHL 22251 VNHL 32251 VNHL 92251
3/4" VNHL 12253 VNHL 22253 VNHL 32253 VNHL 92253
Mercury
Vapor
200
1" VNML 12201 VNML 22201 VNML 32201 VNML 92201
Ex nR II T4 IP66
Ex DP II 11
3/4" VNML 12203 VNML 22203 VNML 32203 VNML 92203
250
1" VNML 12251 VNML 22251 VNML 32251 VNML 92251
3/4" VNML 12253 VNML 22253 VNML 32253 VNML 92253
Ordering Information
V N N L 1 2 1 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VN Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
Lamp Wattage (W)⑤ : Entry Size⑥ Options⑦ 5 - 277
15 - 150 1 - 1" DR - Dome Type Reflector 6 - 240
17 - 175 3 - 3/4" AR - Angle Type Reflector 7 - 230
20 - 200 5 - 1/2" IR - Instant Restrike Type
25 - 250 FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Class I Class II Non-Sparking Dust Ignition
Type Watt. Temp ( )℃ Div. 2 Div. 1 "nR" Proof "DP"
High
Pressure
Sodium
150
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
200
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
250
40 260 (T2B) 160 (T2C) T3 11
55 - - T3 -
Metal
Halide
175
40 - 160 (T2C) T3 11
55 - T3 -
250
40 300 (T2) 160 (T2C) T3 11
55 - - T3 -
Mercury
Vapor
200
40 325 (T1) 165 (T2B) T4 11
55 - - - -
250
40 325 (T1) 165 (T2B) T4 11
55 - - - -
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<VNNL 12251-DR> 0 91.0 50 136
5 91.0 55 140Lamp : NH250 (25000 lm)+
With Guard+
Reflector :+
FRP Dome Reflector
10 91.0 60 140
15 107 65 140
20 123 70 143
25 130 75 136
30 130 80 110
35 127 85 68.3
40 130 90 22.8
45 133
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77
1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62
250 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50
3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41
200 0.8 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34
5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29
150 0.56 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25
7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22
8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19
9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17
10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16
Angle cd/1000 lm Angle cd/1000 lm
<VNHL 12251-DR> 0 102 50 130
5 102 55 140Lamp : MH250 (20500 lm)+
With Guard+
Reflector :+
FRP Dome Reflector
10 98.2 60 144
15 119 65 144
20 133 70 144
25 133 75 144
30 137 80 130
35 133 85 59.6
40 140 90 10.5
45 126
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77
1 .79 .76 .73 .78 .74 .71 .74 .72 .69 .71 .69 .67 .68 .67 .65 .63
250 1 2 .68 .62 .58 .67 .61 .57 .64 .59 .55 .61 .57 .54 .59 .56 .53 .51
3 .59 .52 .47 .58 .51 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .42
175 0.68 4 .52 .44 .39 .50 .44 .38 .48 .43 .38 .47 .41 .37 .45 .40 .37 .35
5 .46 .38 .33 .45 .38 .33 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30
6 .41 .34 .28 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26
7 .37 .30 .25 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22
8 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .20
9 .31 .24 .20 .30 .24 .20 .30 .24 .20 .29 .23 .20 .28 .23 .19 .18
10 .29 .22 .18 .28 .22 .18 .27 .22 .18 .27 .21 .18 .26 .21 .18 .16
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VN Bracket Type > < VN Stanchion Type >
< VN Ceiling Type > < VN Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
VZ Series
Wet Locations
Marine Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof
Non Sparking (Ex nR II T2 IP66)
Class I Division 2 Group A,B,C,D
Class II Division 1,2 Group E,F,G
Class III Division 1
Features Standard Materials
Low ambient capability to -40℃
Wide range of light sources to
meet specific lighting needs - High
Pressure Sodium (HPS): 250 and
400W, Mercury Vapour (MV): 250
and 400W, Metal Halide (MH): 250
and 400W
Restricted Breathing Construction :
Zone 2 only
< VZ >
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Lamp socket :
Porcelain with screw shell
Reflector :
Aluminium sheet /
Fiberglass-Reinforced Polyester
Guard : Stainless steel
Certification
UL Listed File No. E 131747
Certified by UL (Underwriters
Laboratories Inc.), KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Options
With Dome Reflector or 30° Angle
Reflector
Fused to protect ballast and
capacitors
Quartz Auxiliary Lighting come to
full brightness immediately
(Non-hazardous location only)
Compliance
NEC - Class I Division 2 Group
A,B,C,D, / Class II Division 1,2
Group E,F,G / Class III Division 1
UL 844 - Lighting Fixtures for Use
in Hazardous (Classified) Locations
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X, 7, 9
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact
us please.
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage
AC110V/ 220V/ 240V
( See Below)※
Bracket VZNL 32253 18.8 ㎏
Rated Wattage 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt
Hub
Size
Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
250
1" VZNL 12251 VZNL 22251 VZNL 32251 VZNL 92251
Ex nR II T3
3/4" VZNL 12253 VZNL 22253 VZNL 32253 VZNL 92253
400
1" VZNL 12401 VZNL 22401 VZNL 32401 VZNL 92401
Ex nR II T2
3/4" VZNL 12403 VZNL 22403 VZNL 32403 VZNL 92403
Metal
Halide
250
1" VZHL 12251 VZHL 22251 VZHL 32251 VZHL 92251
Ex nR II T3
3/4" VZHL 12253 VZHL 22253 VZHL 32253 VZHL 92253
400
1" VZHL 12401 VZHL 22401 VZHL 32401 VZHL 92401
Ex nR II T2
3/4" VZHL 12403 VZHL 22403 VZHL 32403 VZHL 92403
Mercury
Vapor
250
1" VZML 12251 VZML 22251 VZML 32251 VZML 92251
Ex nR II T3
3/4" VZML 12253 VZML 22253 VZML 32253 VZML 92253
400
1" VZML 12401 VZML 22401 VZML 32401 VZML 92401
Ex nR II T2
3/4" VZML 12403 VZML 22403 VZML 32403 VZML 92403
Ordering Information
V Z N L 1 2 2 5 1 - DR
① ② ③ ④ ⑤ ⑥ ⑦
VZ Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④
NL - High Pressure Sodium 1 - Pendant 1 - 120
HL - Metal Halide 2 - Ceiling 2 - 220
ML - Mercury Vapour 3 - Bracket 3 - 110
9 - Stanchion 4 - 208
5 - 277
Lamp Wattage (W)⑤ Entry Size⑥ Options⑦ 6 - 240
25 - 250 1 - 1" DR - Dome Type Reflector 7 - 230
40 - 400 3 - 3/4" AR - Angle Type Reflector
5 - 1/2" FU - Fused Type
QAL - Quartz Auxiliary Lighting Type
Temperature Performance Data
Lamp Ambient Non Sparking
Type Watt. Temp ( )℃ "nR"
High
Pressure
Sodium
250
40 T3
55 T3
400
40 T2
55 T2
Metal
Halide
250
40 T3
55 T3
400
40 T2
55 T2
Mercury
Vapor
250
40 T3
55 T3
400
40 T2
55 T2
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 13.9 50 86.3<VZNL 22401-DR>
5 14.7 55 93.6
Lamp : NH400 (46000 lm)+
With Globe and without Guard+
Reflector :+
FRP Dome Reflector
10 15.7 60 92.5
15 27.5 65 97.2
20 36.7 70 100
25 40.4 75 104
30 45.0 80 104
35 50.6 85 106
40 70.1 90 106
45 77.9
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .63 .63 .63 .61 .61 .61 .58 .58 .58 .56 .56 .56 .54 .54 .54 .53
1 .52 .49 .47 .51 .48 .46 .49 .46 .44 .46 .45 .43 .44 .43 .42 .40
2 .43 .38 .34 .42 .38 .34 .40 .36 .33 .38 .35 .32 .36 .34 .31 .30
3 .36 .31 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .30 .27 .24 .23
4 .31 .25 .21 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .22 .20 .18
5 .27 .21 .17 .26 .21 .17 .25 .20 .17 .24 .20 .16 .23 .19 .16 .15
6 .24 .18 .14 .23 .18 .14 .22 .17 .14 .21 .17 .14 .20 .16 .13 .12
7 .21 .16 .12 .21 .15 .12 .20 .15 .12 .19 .15 .12 .18 .14 .11 .10
8 .19 .14 .10 .18 .14 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09
9 .17 .12 .09 .17 .12 .09 .16 .12 .09 .16 .12 .09 .15 .11 .09 .08
10 .16 .11 .08 .15 .11 .08 .15 .11 .08 .14 .10 .08 .14 .10 .08 .07
Angle cd/1000 lm Angle cd/1000 lm
0 19.3 50 115<VZHL 22401-DR>
5 20.7 55 111
Lamp : MH400 (34000 lm)+
With Globe and without Guard+
Reflector :+
FRP Dome Reflector
10 22.1 60 113
15 30.2 65 119
20 43.2 70 124
25 54.4 75 128
30 53.9 80 131
35 68.4 85 134
40 67.8 90 139
45 105
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .79 .79 .79 .77 .77 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66
1 .65 .62 .58 .64 .61 .58 .61 .58 .56 .58 .56 .54 .56 .54 .52 .51
2 .54 .48 .43 .53 .47 .43 .50 .46 .42 .48 .44 .41 .46 .42 .40 .38
3 .45 .38 .33 .44 .38 .33 .42 .37 .32 .40 .35 .31 .38 .34 .31 .29
4 .39 .32 .26 .38 .31 .26 .36 .30 .26 .34 .29 .25 .33 .28 .25 .23
5 .34 .27 .21 .33 .26 .21 .31 .25 .21 .30 .25 .21 .29 .24 .20 .19
6 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .25 .21 .17 .16
7 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .23 .18 .15 .13
8 .24 .17 .13 .23 .17 .13 .22 .17 .13 .22 .16 .13 .21 .16 .13 .11
9 .22 .16 .11 .21 .15 .11 .20 .15 .11 .20 .15 .11 .19 .14 .11 .10
10 .20 .14 .10 .19 .14 .10 .19 .14 .10 .18 .13 .10 .17 .13 .10 .09
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< VZ Bracket Type > < VZ Ceiling Type >
< VZ Stanchion Type > < VZ Pendant Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
V Series H.I.D Lighting Fixtures
Auxiliary Lighting
< Auxiliary Lighting >
About Auxiliary Lighting Features V Series Auxiliary Lighting
Momentary voltage outages or dips
can temporarily extinguish HID
lamps which may require up to ten
minutes to restrike. To provide
illumination during this period,
10~20% of the fixtures should be
specified with auxiliary lighting.
Hinged ballast housing for ease
of installation and maintenance
Hubs with integral conduit stop
and bushing to help prevent
damage to field wiring during
installation.
Factory sealed, porcelain with
mogul or medium base socket.
Four mounting arrangements to
suit any lighting layout pendant,
ceiling, wall bracket and
stanchion.
Internal ballasts-separate ballasts
are not required. High power
factor (90%) ballasts reduce
power costs allow more fixtures
per circuit.
Cast aluminium alloy
construction and epoxy powder
finish provide excellent resistant
to corrosion.
Quartz auxiliary is available for
all V Series fixtures (except
those with plastic refractors) by
adding the suffix QAL to the
fixture catalog number.
(Example :
VN NL 1 2 15 1- QAL)
Series VG fixtures with this
option use 100 or 150 watt
quartz lamps. Series VN wattage
fixtures can use up to 250 watt
quartz lamps. Quartz lamps are
not supplied with the fixture
Due to the quartz envelope
surface temperature (exceeding
6000°C), fixtures with this option
are not suitable for Wet
hazardous locations. Contact the
Factory for specific fixture
suitabilities.
Instant Restart
Available for 70-150 Watt VG Series
High Pressure Sodium Fixtures by
adding Suffix "IR" to catalog
number (Ex: VN NL 1 2 15 1 - IR).
Additional instant restart interior
circuitry may decrease High
Pressure Sodium lamp life. Feature
will not affect fixture suitability in
hazardous location applications
Incandescent Auxiliary
With a surface lamp temperature
lower than quartz, incandescent
auxiliary lamps are available for
Series V fixtures.
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Flameproof-Non Sparking (Ex dnR IIC T4)
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)
Electrical Ratings
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 50W/ 70W/ 100W/ 150W/
175W/ 200W/ 250W
Rated Frequency 50Hz/ 60Hz
Weight
Entry Sizes 1/2", 3/4", 1"
Mounting Type Catalog No. Weight
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
Pendant EVNNL 1255 11.5 Kg
< EVN >
Standard Finish
Dark Gray
If you want another color, contact us
please.
Certification
Certified by KOSHA (Korea
Occupational Safety & Health Agency),
KGS (Korea Gas Safety Corporation),
and the others.
Compliance
IEC 60079-0, 1, 15
NEMA 3, 3R, 4, 4X, 7, 9
Options
With Dome Reflector or 30°
Angle Reflector with SMC or High
Grade Aluminium
With Choke or Lead Peak type
Ballast
For various voltage from 110V to
240V
For 50Hz/ 60Hz
Application Features
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities, wastewater
and sewage treatment plants, offshore,
dockside and other harbor installations as
well as other heavy industrial applications.
wherever the damaging effects of water,
wind, snow, sleet, hot sun or any
combination of these elements are found.
in withstands the harshest of corrosive
environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere consisting
of a mixture with air of flammable
substances in the form of gas, vapour or
mist is not likely to occur in normal
operation but, if it does occur, will persist
for a short period only.
where combustible dust, moisture, dirt are
present and vibration, corrosion, rough
usage are problems.
Enclosure in glass fiber
reinforced polyester resin,
provide excellent resistant to
corrosion so have a long life.
Enclosure contain ultraviolet
interception ingredient to
resist transformation.
Easy installation and
maintenance.
Pendant mounting module
equipped with integral hub
set screws for vibration
resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use
of both hands when wiring.
Standard Materials
Housing, mounting modules,
component pallets : Fiberglass
reinforced polyester resin
Globe : Heat resistant hard glass
Gasket : Silicone rubber
Reflector : Fiberglass Reinforced
Polyester
External Hardware : Stainless
steel, Brass
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification
High
Pressure
Sodium
50
1/2" EVNNL 1055 EVNNL 2055 EVNNL 3055 EVNNL 9055
Ex dnR IIC T4 IP66
Ex nR II T4 IP66
Ex DP II 11 IP66
3/4" EVNNL 1053 EVNNL 2053 EVNNL 3053 EVNNL 9053
70
1/2" EVNNL 1075 EVNNL 2075 EVNNL 3075 EVNNL 9075
3/4" EVNNL 1073 EVNNL 2073 EVNNL 3073 EVNNL 9073
100
1/2" EVNNL 1105 EVNNL 2105 EVNNL 3105 EVNNL 9105
3/4" EVNNL 1103 EVNNL 2103 EVNNL 3103 EVNNL 9103
150
1/2" EVNNL 1155 EVNNL 2155 EVNNL 3155 EVNNL 9155
3/4" EVNNL 1153 EVNNL 2153 EVNNL 3153 EVNNL 9153
200
1/2" EVNNL 1205 EVNNL 2205 EVNNL 3205 EVNNL 9205
3/4" EVNNL 1203 EVNNL 2203 EVNNL 3203 EVNNL 9203
250
1/2" EVNNL 1255 EVNNL 2255 EVNNL 3255 EVNNL 9255
3/4" EVNNL 1253 EVNNL 2253 EVNNL 3253 EVNNL 9253
Metal
Halide
100
1/2" EVNHL 1105 EVNHL 2105 EVNHL 3105 EVNHL 9105
Ex dnR IIC T4 IP66
Ex nR II T3 IP66
Ex DP II 11 IP66
3/4" EVNHL 1103 EVNHL 2103 EVNHL 3103 EVNHL 9103
175
1/2" EVNHL 1175 EVNHL 2175 EVNHL 3175 EVNHL 9175
3/4" EVNHL 1173 EVNHL 2173 EVNHL 3173 EVNHL 9173
250
1/2" EVNHL 1255 EVNHL 2255 EVNHL 3255 EVNHL 9255 Ex dnR IIC T3 IP66
Ex nR II T3 IP663/4" EVNHL 1253 EVNHL 2253 EVNHL 3253 EVNHL 9253
Ordering Information Dimension
E V N N L 1 0 5 5 - DR
① ② ③ ④ ⑤ ⑥
EVN Lighting Fixture① Lamp Type②
NL - High Pressure Sodium
Mounting Type③ HL - Metal Halide
1 - Pendant ML - Mercury Vapour
2 - Ceiling
3 - Bracket Lamp Wattage (W)④
9 - Stanchion 05 - 50
07 - 70
Entry Size⑤ 10 - 100
1 - 1" 15 - 150
3 - 3/4" 17 - 175
5 - 1/2" 20 - 200
25 - 250
Options⑥
DR - Dome Reflector
AR - Angle Reflector
C※ an order Aluminium Reflector instead of FRP Reflector
< Pendant Type > < Ceiling Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EVNNL 2255-DR> 0 81.0 50 135
5 81.0 55 138Lamp : NH250 (25000 lm)+
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 81.0 60 145
15 87.8 65 148
20 97.9 70 148
25 111 75 148
30 115 80 125
35 115 85 81.0
40 122 90 33.8
45 128
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio/RCR 20% Effective Floor Cavity Reflectance
0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77
1 .79 .75 .72 .77 .73 .70 .74 .71 .68 .70 .68 .66 .68 .66 .64 .62
250 1 2 .67 .61 .56 .65 .60 .55 .62 .58 .54 .60 .56 .52 .57 .54 .51 .49
3 .57 .50 .44 .56 .49 .44 .54 .48 .43 .51 .46 .42 .49 .45 .42 .40
200 0.8 4 .50 .42 .36 .49 .42 .36 .47 .40 .36 .45 .39 .35 .43 .38 .34 .33
5 .44 .36 .30 .43 .36 .30 .41 .35 .30 .40 .34 .30 .38 .33 .29 .27
150 0.56 6 .39 .31 .26 .38 .31 .26 .37 .30 .26 .35 .30 .25 .34 .29 .25 .23
7 .35 .28 .23 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20
8 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .28 .23 .19 .18
9 .29 .22 .18 .29 .22 .18 .28 .22 .18 .27 .21 .17 .26 .21 .17 .16
10 .27 .20 .16 .26 .20 .16 .26 .20 .16 .25 .19 .16 .24 .19 .16 .14
Angle cd/1000 lm Angle cd/1000 lm
<EVNHL 2175-DR> 0 91.6 50 149
5 91.6 55 143Lamp : MH175 (14000 lm)+
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 97.4 60 143
15 97.4 65 143
20 115 70 143
25 126 75 137
30 132 80 132
35 137 85 91.6
40 137 90 17.2
45 143
Multipliers Coefficients of Utilization - Zonal Cavity
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
250 1.47 0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81
1 .82 .78 .75 .80 .77 .74 .77 .74 .71 .74 .71 .69 .71 .69 .67 .65
175 1 2 .70 .64 .59 .69 .63 .58 .66 .61 .57 .63 .59 .55 .60 .57 .54 .52
3 .60 .53 .47 .59 .52 .47 .57 .51 .46 .54 .49 .45 .52 .48 .44 .42
4 .53 .45 .39 .52 .44 .39 .50 .43 .38 .48 .42 .38 .46 .41 .37 .35
5 .47 .39 .33 .46 .38 .33 .44 .37 .32 .42 .36 .32 .41 .36 .32 .30
6 .42 .34 .28 .41 .34 .28 .39 .33 .28 .38 .32 .28 .37 .31 .27 .26
7 .38 .30 .25 .37 .30 .25 .36 .29 .24 .34 .29 .24 .33 .28 .24 .22
8 .34 .27 .22 .34 .27 .22 .33 .26 .22 .32 .26 .22 .31 .25 .21 .20
9 .31 .24 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .18
10 .29 .22 .18 .28 .22 .18 .28 .22 .18 .27 .21 .18 .26 .21 .17 .16
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Compact Fluorescent Lighting Fixtures
EVN Series
Wet Locations
NEMA 3,3R,4,4X,7,9
Type of Explosion-proof Technical Data
Electrical Ratings
Non Sparking (Ex nR II T4 IP66)
Dust Ignition-proof (Ex DP II 11 IP66)
Rated Voltage AC110V/ 220V/ 240V
Rated Wattage 13W×3, 18W×3, 26W×3
< EVNCL 1263 >
Rated Frequency 50Hz/ 60Hz
Entry Sizes 1/2", 3/4", 1"
Weight
Mounting Type Catalog No. Weight
Pendant EVNCL 1263 9 Kg
Standard Materials
Housing, mounting modules,
component pallets : Fiber glass
reinforced polyester resin
Globe :
Heat resistant hard glass
Gasket : Silicone rubber
Reflector :
Fiber glass Reinforced Polyester
External Hardware :
Stainless steel, Brass
Application Features Certification
EVN Series lighting fixtures are used ;
in manufacturing plants, refineries,
chemical, petrochemical and other
industrial process facilities,
wastewater and sewage treatment
plants, offshore, dockside and other
harbor installations as well as other
heavy industrial applications.
wherever the damaging effects of
water, wind, snow, sleet, hot sun or
any combination of these elements
are found.
in withstands the harshest of
corrosive environments.
to provide low wattage spot and
floodlighting.
where an explosive atmosphere
consisting of a mixture with air of
flammable substances in the form
of gas, vapour or mist is not likely
to occur in normal operation but, if
it does occur, will persist for a
short period only.
where combustible dust, moisture,
dirt are present and vibration,
corrosion, rough usage are
problems.
Enclosure in glass fiber reinforced
polyester resin, provide excellent
resistant to corrosion so have a
long life.
Enclosure contain ultraviolet
interception ingredient to resist
transformation.
Easy installation and maintenance
Internal type ballast.
Pendant mounting module
equipped with integral hub set
screws for vibration resistance.
Guard, hub inserts, stanchion
elbow and hardware made of
stainless steel for maximum
resistance to corrosion.
Grounding wire for safety.
Hinged assembly allows the
fixture to hang free during
installation to permit the use of
both hands when wiring.
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Compliance
IEC 60079-0, 15
NEMA 3, 3R, 4, 4X
Standard Finish
Dark Gray
If you want another color,
contact us please.
Options
With Dome Reflector or 30°
Angle Reflector with SMC or
High Grade Aluminium
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification
Compact
Fluorescent
13W×3
1/2" EVNCL 1135 EVNCL 2135 EVNCL 3135 EVNCL 9135
Ex nR II T4
Ex DP II 12
3/4" EVNCL 1133 EVNCL 2133 EVNCL 3133 EVNCL 9133
18W×3
1/2" EVNCL 1185 EVNCL 2185 EVNCL 3185 EVNCL 9185
3/4" EVNCL 1183 EVNCL 2183 EVNCL 3183 EVNCL 9183
26W×3
1/2" EVNCL 1265 EVNCL 2265 EVNCL 3265 EVNCL 9265
3/4" EVNCL 1263 EVNCL 2263 EVNCL 3263 EVNCL 9263
Ordering Information EVN Lighting Fixture①
E V N C L 1 1 3 5 - DR Lamp Type②
① ② ③ ④ ⑤ ⑥ CL - Compact Fluorescent
Mounting Type③ Lamp Wattage (W)④ Entry Size⑤ Options⑥
1 - Pendant 13 - 13W×3 1 - 1" DR - Dome Reflector with SMC
2 - Ceiling 18 - 18W×3 3 - 3/4" AR - Angle Reflector with SMC
3 - Bracket 26 - 26W×3 5 - 1/2" C※ an order Aluminium Reflector instead of FRP
Reflector9 - Stanchion
▞ Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
<EVNCL 2265-DR> 0 86.0 50 111
5 86.0 55 111Lamp : CFL26+ ×3 (5400 lm)
With Globe and without Guard+
Reflector : FRP Dome Reflector+
10 86.0 60 109
15 87.5 65 106
20 90.6 70 96.9
25 93.7 75 82.9
30 98.4 80 64.1
35 103 85 43.7
40 106 90 25.0
45 109
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .58 .58 .58 .57
1 .58 .56 .53 .57 .55 .53 .55 .53 .51 .52 .51 .49 .50 .49 .48 .47
2 .50 .46 .43 .49 .45 .42 .47 .44 .41 .45 .43 .40 .44 .41 .39 .38
3 .44 .39 .35 .43 .38 .35 .41 .37 .34 .40 .36 .33 .38 .35 .33 .32
4 .38 .33 .29 .38 .33 .29 .36 .32 .29 .35 .31 .28 .34 .30 .28 .27
5 .34 .29 .25 .34 .28 .25 .32 .28 .24 .31 .27 .24 .30 .27 .24 .23
6 .31 .25 .22 .30 .25 .21 .29 .25 .21 .28 .24 .21 .27 .24 .21 .20
7 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .19 .25 .21 .18 .17
8 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .16 .15
9 .23 .18 .15 .23 .18 .15 .22 .18 .15 .21 .18 .15 .21 .17 .15 .14
10 .21 .17 .14 .21 .17 .14 .20 .16 .14 .20 .16 .14 .19 .16 .13 .12
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Dimension
< EVN Bracket Type > < EVN Stanchion Type >
< EVN Pendant Type > < EVN Ceiling Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EU Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
Type of Explosion-proof
Flameproof (Ex d IIB T4)
Dust Ignition-proof (Ex DP II 12)
< EU >
Application Features
EU Series lighting fixtures are used;
in tunnels, building entrances
and similar locations where
moisture, dirt, chemicals or
rough usage are a problem.
in heavy process industries
having environments where
flammable or explosive vapors or
gases, or where combustible
dusts are present.
in areas where combustible dusts
and flammable vapors are
present simultaneously.
in hazardous areas, both indoors
and outdoors where long life
and low maintenance costs are
desired.
where high light output is
needed but space is limited.
where ignitable concentrations of
flammable gases, vapors, liquids
or dusts can exist some of the
time under normal operating
conditions.
Lighting unit and ballast are
constructed separately so as to
protect the ballast from the heat
of the lamp.
Lighting unit is screwed onto the
top of the mounting box and the
ballast to the side.
Globe assembly is securely
hinged to the body.
Ballast is a high quality one
maintaining much safety on
strength of enclosure,
weatherproof and temperature
rise.
Mounting box has four-way
conduit entries and a large
access cover for wiring.
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color,
contact us please.
Standard Materials Certification Compliance
Enclosure : Die casting aluminium
Globe : Heat resistant hard glass
Inner Reflector : High purity
aluminium
External Hardware : Stainless steel
Mounting Box : Cast aluminium alloy
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas
Safety Corporation), and the
others.
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Technical Data Weight
Electrical Rating Mounting Type Catalog No. Weight
Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Ceiling EUNL 32210 8.6 ㎏
Rated Wattage 50W/ 70W/ 100W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
120V/ 208V/ 277V/ 460V
If you need more information, contact us please.⇨
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Volts Pendant Ceiling
90°
Bracket
40°
Bracket
Certification
High Pressure Sodium
50
100-120 EUNL 31105 EUNL 32105 EUNL 33105 EUNL 34105
Ex d IIB T3
200-220 EUNL 31205 EUNL 32205 EUNL 33205 EUNL 34205
70
100-120 EUNL 31107 EUNL 32107 EUNL 33107 EUNL 34107
200-220 EUNL 31207 EUNL 32207 EUNL 33207 EUNL 34207
100
100-120 EUNL 31110 EUNL 32110 EUNL 33110 EUNL 34110
200-220 EUNL 31210 EUNL 32210 EUNL 33210 EUNL 34210
Metal Halide 100
100-120 EUHL 31110 EUHL 32110 EUHL 33110 EUHL 34110
Ex d IIB T4
200-220 EUHL 31210 EUHL 32210 EUHL 33210 EUHL 34210
Mercury Vapor 100
100-120 EUML 31110 EUML 32110 EUML 33110 EUML 34110
200-220 EUML 31210 EUML 32210 EUML 33210 EUML 34210
* For Pole type, see pole section (2L-51)
Ordering Information Temperature Performance Data
E U N L 3 2 1 1 0 Lamp Ambient Flameproof Dust-Ignition
① ② ③ ④ ⑤ ⑥ Type Watt. Temp ( )℃ "d" "DP"
EU Lighting Fixture① Mounting Type④
H.I.D
50
40 T4 12
1 - Pendant 55 - -
Lamp Type② 2 - Ceiling
70
40 T4 12
NL - H.P.Sodium 3 - 90° Bracket 55 - -
HL - Metal Halide 4 - 40° Bracket
100
40 T4 12
ML - Mercury Vapor 55 - -
Voltage (V)⑤
Type of Lighting Fixture③ 1 - 100-120
3 - EUL Type 2 - 200-220
Wattage (W)⑥
05 - 50, 07 - 70, 10 - 100
Dimension
<Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUNL 32110> 0 93.7 50 107
5 76.8 55 112Lamp : NH100 (9000 lm)+
With Guard+ 10 77.8 60 116
15 81.5 65 125
20 76.8 70 131
25 77.8 75 132
30 81.5 80 133
35 87.2 85 139
40 91.9 90 143
45 99.4
Coefficients of Utilization - Zonal Cavity
Multipliers
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
(For use with
candlepower
curves only)
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71
1 .71 .67 .63 .69 .66 .62 .66 .63 .60 .63 .61 .59 .61 .59 .57 .55
100 1 2 .59 .53 .48 .58 .52 .47 .55 .50 .46 .52 .48 .45 .50 .47 .44 .42
3 .50 .43 .37 .49 .42 .37 .46 .41 .36 .44 .39 .35 .42 .38 .34 .33
70 0.5 4 .43 .36 .30 .42 .35 .30 .40 .34 .29 .38 .33 .29 .37 .32 .28 .26
5 .38 .30 .25 .37 .30 .25 .35 .29 .24 .34 .28 .24 .32 .27 .24 .22
50 0.25 6 .34 .26 .21 .33 .26 .21 .31 .25 .21 .30 .25 .20 .29 .24 .20 .19
7 .30 .23 .18 .30 .23 .18 .28 .22 .18 .27 .22 .18 .26 .21 .18 .16
8 .27 .21 .16 .27 .20 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14
9 .25 .19 .14 .25 .18 .14 .24 .18 .14 .23 .18 .14 .22 .17 .14 .12
10 .23 .17 .13 .23 .17 .13 .22 .16 .13 .21 .16 .13 .21 .16 .13 .11
Angle /1000㏅ ㏐ Angle /1000㏅ ㏐
<EUHL 32110> 0 123 50 98.7
5 112 55 104Lamp : MH100 (6500 lm)+
With Guard+ 10 114 60 109
15 117 65 149
20 116 70 147
25 135 75 148
30 140 80 144
35 121 85 134
40 101 90 106
45 97.3
Coefficients of Utilization - Zonal Cavity
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance
0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80
1 .80 .76 .72 .78 .74 .71 .75 .72 .69 .72 .69 .67 .69 .67 .65 .63
2 .67 .61 .55 .66 .60 .54 .63 .58 .53 .60 .56 .52 .57 .54 .51 .49
3 .57 .50 .44 .56 .49 .43 .54 .47 .42 .51 .46 .41 .49 .45 .41 .39
4 .50 .42 .36 .49 .41 .35 .47 .40 .35 .45 .39 .34 .43 .38 .34 .32
5 .44 .36 .30 .43 .36 .30 .41 .35 .29 .40 .34 .29 .38 .33 .29 .27
6 .40 .32 .26 .39 .31 .26 .37 .30 .25 .36 .30 .25 .34 .29 .25 .23
7 .36 .28 .23 .35 .28 .23 .34 .27 .22 .33 .27 .22 .31 .26 .22 .20
8 .33 .25 .20 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .18
9 .30 .23 .18 .30 .23 .18 .29 .22 .18 .28 .22 .18 .27 .22 .18 .16
10 .28 .21 .17 .27 .21 .17 .27 .21 .17 .26 .20 .16 .25 .20 .16 .15
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
H.I.D Lighting Fixtures
EA Series
Wet Locations
Factory Sealed
NEMA 3, 3R, 7
< EA >
Type of Explosion-proof
Flameproof (Ex d IIB T4 H2)
Flameproof (Ex d IIC T4 H2)
Standard Materials
Enclosure : Die casting aluminium alloy
Globe : Heat resistant hard glass
Inner Reflector : High purity aluminium
Guard : Stainless steel
Standard Finish
MUNSELL No. 7.5BG 6/1.5
If you want another color, contact us please.
Application Features Globe assembly is securely hinged
to the body.
Easy installation and maintenance.
Hinged assembly allows the fixture
to hang free during installation to
permit the use of both hands
when wiring.
Can use compact fluorescent lamp
45W instead of HID lamp without
external ballast.
EA Series lighting fixture are used ;
in heavy process industries having
environments where flammable or
explosive vapors or gases, or
where combustible dusts are
present.
in paint spray booth suitability
provides efficient, economical HID
lighting for paint spray areas.
in hazardous areas, both indoors
and outdoors where long life and
low maintenance costs are
desired.
in hazardous locations requiring
elevated ambient capability.
in marine applications where water
spray and corrosive atmospheres
are considerations.
Lighting unit and ballast are
constructed separately so as
to protect the ballast from
the heat of the lamp.
Base of the body and the
top of the globe holder have
accurate tapered cylindrical
surfaces and are secured by
four socket head captive
screw.
Lighting unit is screwed onto
the top of the mounting box
and the ballast to the side.
Pendant mounting module
equipped with integral hub
set screws for vibration
resistance.
Globe assembly is securely
hinged to the body.
Compliance & Certification
IEC 60079-0, 1
NEMA 3, 3R, 7
IP 55
Certified by KOSHA (Korea
Occupational Safety & Health
Agency), KGS (Korea Gas Safety
Corporation), and the others.
Technical Data Lamp Replacement
Electrical Rating
Rated Voltage AC110V/ 220V/ 240V ( See Below)※
Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W
Rated Frequency 50Hz/ 60Hz
Entry Size 1/2", 3/4", 1"
Also you can order various voltage :※
110V/ 120V/ 208V/ 220V/ 240V/ 277V/ 460V
Weight
Mounting Type Catalog No. Weight
Small (Ceiling) EANL 2215 17.3 ㎏
Large (Ceiling) EAML 2240 28.3 ㎏
If you need more information, contact us please.☞
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Ordering Number
Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification
High
Pressure
Sodium
150 EANL 2115 EANL 2215 EANL 2315 EANL 2415
Ex d IIC T4200 EANL 2120 EANL 2220 EANL 2320 EANL 2420
250 EANL 2125 EANL 2225 EANL 2325 EANL 2425
400 EANL 2140 EANL 2240 EANL 2340 EANL 2440 Ex d IIB T3
Metal
Halide
175 EAHL 2117 EAHL 2217 EAHL 2317 EAHL 2417
Ex d IIC T4
250 EAHL 2125 EAHL 2225 EAHL 2325 EAHL 2425
400 EAHL 2140 EAHL 2240 EAHL 2340 EAHL 2440 Ex d IIB T3
Mercury
Vapor
200 EAML 2120 EAML 2220 EAML 2320 EAML 2420
Ex d IIC T4
250 EAML 2125 EAML 2225 EAML 2325 EAML 2425
400 EAML 2140 EAML 2240 EAML 2340 EAML 2440 Ex d IIB T3
Dimension Ordering Information
<Ceiling Type> <Pendant Type>
<40°Bracket Type>
<90°Bracket Type>
E A N L 2 1 1 5
① ② ③ ④ ⑤
EA Lighting Fixture① Mounting Type④
1 - Pendant
2 - Ceiling
Lamp Type② 3 - 90° Bracket
NL - High Pressure Sodium 4 - 40° Bracket
HL - Metal Halide
ML - Mercury Vapour ⑤ Lamp Wattage(w)
15 - 150
17 - 175
Model Type③ 20 - 200
2 - EA Type 25 - 250
40 - 400
Temperature Performance Data
Lamp Ambient Flame
Type Watt. Temp ( )℃ Proof "d"
High
Pressure
Sodium
150
40 T4
55 T4
200
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3
Metal
Halide
175
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3
Mercury
Vapor
200
40 T4
55 T4
250
40 T4
55 T4
400
40 T3
55 T3
Lighting Fixture
Copyright by NAMBUK Electric Co., LTD. 2004
Photometric Data
Angle cd/1000 lm Angle cd/1000 lm
0 122 50 161<EAHL 2225>
5 108 55 171
Lamp : MH250 (20500 lm)+
With Globe and without Guard+
10 94.4 60 164
15 105 65 126
20 143 70 115
25 170 75 112
30 147 80 80.4
35 133 85 38.4
40 129 90 17.4
45 133
Coefficients of Utilization - Zonal Cavity
Multipliers
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74
1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62
250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52
3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43
175 0.68 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36
5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31
6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27
7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24
8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19
10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17
Angle cd/1000 lm Angle cd/1000 lm
0 172 50 118<EANL 2225>
5 135 55 125
Lamp : NH250 (25000 lm)+
With Globe and without Guard+ 10 94.5 60 125
15 105 65 125
20 142 70 108
25 182 75 87.8
30 142 80 67.5
35 108 85 50.6
40 97.9 90 30.4
45 101
Coefficients of Utilization - Zonal Cavity
Multipliers
(For use with
candlepower
curves only)
%Effective Ceiling
Cavity Reflectance( cc)ρ
80 70 50 30 10 0
%Wall
Reflectance(ρw)
50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0
Lamp
Watts
Conversion
Factor
Room Cavity Ratio
RCR
20% Effective Floor Cavity Reflectance
0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74
1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62
250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52
3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43
200 0.8 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36
5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31
150 0.56 6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27
7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24
8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21
9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19
10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat
Nb cat

Más contenido relacionado

La actualidad más candente

8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators 8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators
Thorne & Derrick International
 

La actualidad más candente (14)

Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
Stahl 6014/6414 Sheet Steel Light Fitting - ATEX Zone 1 Zone 2 Hazardous Area...
 
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
Stahl Lighting 6014 Light Fitting For Fluorescent Lamps - ATEX Zone 1 Hazardo...
 
Hawke 501/421 Hazardous Area Cable Gland
Hawke 501/421 Hazardous Area Cable GlandHawke 501/421 Hazardous Area Cable Gland
Hawke 501/421 Hazardous Area Cable Gland
 
E367 dah heavy duty
E367 dah heavy dutyE367 dah heavy duty
E367 dah heavy duty
 
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
|AKBAR TRADING EST. SAUDI ARABIA| HAWKE 487 489 REDUCER ต่อม สายเคเบิล
 
Tyco Guroflex High Voltage Electrical Insulating Compound
Tyco Guroflex High Voltage Electrical Insulating CompoundTyco Guroflex High Voltage Electrical Insulating Compound
Tyco Guroflex High Voltage Electrical Insulating Compound
 
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6521_4 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 
Prysmian BICON 374 Plastic Two Bolt Cable Cleats - Spec Sheet
Prysmian BICON 374 Plastic Two Bolt Cable Cleats - Spec SheetPrysmian BICON 374 Plastic Two Bolt Cable Cleats - Spec Sheet
Prysmian BICON 374 Plastic Two Bolt Cable Cleats - Spec Sheet
 
3M Cold Shrink Joint 145 kV Inline (Straight Through) SS145-II
3M Cold Shrink Joint 145 kV Inline (Straight Through) SS145-II3M Cold Shrink Joint 145 kV Inline (Straight Through) SS145-II
3M Cold Shrink Joint 145 kV Inline (Straight Through) SS145-II
 
Gled ml35-en
Gled ml35-enGled ml35-en
Gled ml35-en
 
8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators 8443-2 3M Silicone Rubber Cold Shrink Insulators
8443-2 3M Silicone Rubber Cold Shrink Insulators
 
Safety Catalog
Safety CatalogSafety Catalog
Safety Catalog
 
Shrinktek SPDW Heat Shrink Tubing - Dual Wall Flame Retarded Heat Shrink Tubing
Shrinktek SPDW Heat Shrink Tubing - Dual Wall Flame Retarded Heat Shrink TubingShrinktek SPDW Heat Shrink Tubing - Dual Wall Flame Retarded Heat Shrink Tubing
Shrinktek SPDW Heat Shrink Tubing - Dual Wall Flame Retarded Heat Shrink Tubing
 
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area LightingStahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
Stahl 6121 Floodlight - ATEX Zone 1 Zone 2 Hazardous Area Lighting
 

Similar a Nb cat

Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Thorne & Derrick International
 
AMS - Arctic Pad - Technical Information
AMS - Arctic Pad - Technical InformationAMS - Arctic Pad - Technical Information
AMS - Arctic Pad - Technical Information
jphawkins
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry Applications
Thorne & Derrick UK
 
New Star Plasma Brochure
New Star Plasma BrochureNew Star Plasma Brochure
New Star Plasma Brochure
Paul Mutch
 

Similar a Nb cat (20)

Reflectores holophane
Reflectores holophaneReflectores holophane
Reflectores holophane
 
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
Hellermann Tyton Heat Shrink Cable Boots, Transitions & Moulded Shapes
 
3M Cold Shrink Cable Splice Kits - 8420 Series
3M Cold Shrink Cable Splice Kits - 8420 Series3M Cold Shrink Cable Splice Kits - 8420 Series
3M Cold Shrink Cable Splice Kits - 8420 Series
 
3M Cold Shrink Tubing For Subsea, Offshore & Underwater Protection Of Equipment
3M Cold Shrink Tubing For Subsea, Offshore & Underwater Protection Of Equipment3M Cold Shrink Tubing For Subsea, Offshore & Underwater Protection Of Equipment
3M Cold Shrink Tubing For Subsea, Offshore & Underwater Protection Of Equipment
 
3M Silicone Cold Shrink Tubes Technical Data Sheet
3M  Silicone Cold Shrink Tubes Technical Data Sheet3M  Silicone Cold Shrink Tubes Technical Data Sheet
3M Silicone Cold Shrink Tubes Technical Data Sheet
 
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
Cooper Crouse Hinds NVMV Series Ex Protected Luminaire for IEC and ATEX Appli...
 
Cáp tàu thủy - TMC Offshore Cable Catalogue
Cáp tàu thủy - TMC Offshore Cable CatalogueCáp tàu thủy - TMC Offshore Cable Catalogue
Cáp tàu thủy - TMC Offshore Cable Catalogue
 
Abtech SX Stainless Steel And Mild Steel Enclosures
Abtech SX Stainless Steel And Mild Steel EnclosuresAbtech SX Stainless Steel And Mild Steel Enclosures
Abtech SX Stainless Steel And Mild Steel Enclosures
 
JAREL EXPORT
JAREL EXPORTJAREL EXPORT
JAREL EXPORT
 
Elematic cable protection - אלמטיק
Elematic cable protection - אלמטיקElematic cable protection - אלמטיק
Elematic cable protection - אלמטיק
 
Lewden Electrical Palazzoli ATEX Solutions for Explosive Atmospheres - Indust...
Lewden Electrical Palazzoli ATEX Solutions for Explosive Atmospheres - Indust...Lewden Electrical Palazzoli ATEX Solutions for Explosive Atmospheres - Indust...
Lewden Electrical Palazzoli ATEX Solutions for Explosive Atmospheres - Indust...
 
AMS - Arctic Pad - Technical Information
AMS - Arctic Pad - Technical InformationAMS - Arctic Pad - Technical Information
AMS - Arctic Pad - Technical Information
 
Взрывозащищенные моторы Ex BARTEC
Взрывозащищенные моторы Ex BARTECВзрывозащищенные моторы Ex BARTEC
Взрывозащищенные моторы Ex BARTEC
 
Utvflex reeling cables
Utvflex reeling cablesUtvflex reeling cables
Utvflex reeling cables
 
ABB Flame Proof motors catalogue
ABB Flame Proof motors catalogueABB Flame Proof motors catalogue
ABB Flame Proof motors catalogue
 
Thông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakersThông số kĩ thuật siemens miniature circuit breakers
Thông số kĩ thuật siemens miniature circuit breakers
 
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical EnclosuresCe-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
Ce-Tek - Industrial, High Voltage & Hazardous Area Electrical Enclosures
 
ASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry ApplicationsASCO Solenoid Valves - Process Industry Applications
ASCO Solenoid Valves - Process Industry Applications
 
Gates advantage Hydraulic Hose and Couplings
Gates advantage Hydraulic Hose and CouplingsGates advantage Hydraulic Hose and Couplings
Gates advantage Hydraulic Hose and Couplings
 
New Star Plasma Brochure
New Star Plasma BrochureNew Star Plasma Brochure
New Star Plasma Brochure
 

Más de Hai Pham

05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng
Hai Pham
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-eng
Hai Pham
 
02 custodie eng
02 custodie eng02 custodie eng
02 custodie eng
Hai Pham
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione eng
Hai Pham
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stations
Hai Pham
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng
Hai Pham
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_eng
Hai Pham
 
01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_eng
Hai Pham
 
System accessories
System accessoriesSystem accessories
System accessories
Hai Pham
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact medium
Hai Pham
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)
Hai Pham
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34
Hai Pham
 

Más de Hai Pham (13)

05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng05 pulsantiere prese-spine-eng
05 pulsantiere prese-spine-eng
 
06 pinze di-terra-eng
06 pinze di-terra-eng06 pinze di-terra-eng
06 pinze di-terra-eng
 
02 custodie eng
02 custodie eng02 custodie eng
02 custodie eng
 
01 illuminazione eng
01 illuminazione eng01 illuminazione eng
01 illuminazione eng
 
05 multiple control stations
05 multiple control stations05 multiple control stations
05 multiple control stations
 
03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng03 feam%20 cable%20glands_eng
03 feam%20 cable%20glands_eng
 
02 feam enclosures_eng
02 feam enclosures_eng02 feam enclosures_eng
02 feam enclosures_eng
 
01 feam lighting_eng
01 feam lighting_eng01 feam lighting_eng
01 feam lighting_eng
 
System accessories
System accessoriesSystem accessories
System accessories
 
Cm compact medium
Cm   compact mediumCm   compact medium
Cm compact medium
 
Ps smart
Ps smartPs smart
Ps smart
 
New dk ps rack brochure (final)
New dk ps rack brochure (final)New dk ps rack brochure (final)
New dk ps rack brochure (final)
 
Catalogue 34
Catalogue 34Catalogue 34
Catalogue 34
 

Nb cat

  • 1. SECTION - 1L Incandescent Lighting Fixture
  • 2. SECTION 1L Incandescent Lighting Fixtures INDEX Model Lamp Type / Watt. Certification for Explosion-proof PAGEIncandescent lamp IEC UL 20 60 100 150 200 300 VDY ● ● 1L - 1 SYL ● ● Ex e II T1 1L - 4 EML ● ● Ex d IIB T3 1L - 7 EUL ● ● Ex d IIB T3 1L - 9 EULS ● Ex d IIB T4 Ex DP II 12 IP55 1L - 12 EFL ● ● ● Ex d IIC T3 Ex d IIC T5 Class I Division 1,2 Group C,D 1L - 15 POLE TYPE Flameproof, Increased Safety, Vaportight Type Pole 1L -19
  • 3. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures VDY Series Weathertight NEMA 3, 3R, 5 Application Features Standard Materials VDY Series lighting fixtures are used ; in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment plants, offshore, dockside and other harbor installations as well as other heavy industrial applications. wherever the damaging effects of wind, snow, sleet, or hot sun are found. in marine applications where water spray and corrosive atmospheres are considerations. in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas. in industrial areas, both indoors and outdoors where long life and low maintenance costs are desired. in Industrial locations requiring elevated ambient capability. The lighting fixture has simple construction. The screw neck globe and the guard are screwed on to the body applying the reflector in its position by the guard. Synthetic rubber gasket is used between the body and globe, so that the lamp housing is sealed against vapors and dusts. Relamping is easily done by opening lower half of the guard and unscrewing the globe. H.I.D lighting fixture has external type ballast. Body : Die casting aluminium Globe : Heat resistant hard glass Reflector : White coating aluminium Mounting Box : Cast aluminium alloy Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. < VDY > Certification Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Compliance Technical Data IP55 Electrical Ratings Rated Voltage AC110V/ 220V/ 240V/ DC110V Rated Wattage 100W/ 200W Rated Frequency 50Hz/ 60Hz Entry Sizes 1/2", 3/4", 1" Weight Mounting Type Catalog No. Weight Ceiling (Small) VDY 2105 2.2 kg Ceiling (Large) VDY 2205 4.5 kg If you need more information, contact us please.⇨
  • 4. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket Incandescent Lamp 100 1/2" VDY 1105 VDY 2105 VDY 3105 VDY 4105 3/4" VDY 1103 VDY 2103 VDY 3103 VDY 4103 200 1/2" VDY 1205 VDY 2205 VDY 3205 VDY 4205 3/4" VDY 1203 VDY 2203 VDY 3203 VDY 4203 Ordering Information V D Y 1 1 0 5 ① ② ③ ④ VDY Lighting Fixture① : Mounting Type② : Lamp Wattage (W)③ : Entry Size④ 1 - Pendant 10 - 100 1 - 1" 2 - Ceiling 20 - 200 3 - 3/4" 3 - 90° Bracket 5 - 1/2" 4 - 40° Bracket Photometric Data Angle cd/1000 lm Angle cd/1000 lm <VDY 2105> 0 145 50 130 5 135 55 115Lamp : IL100 (1250 lm)+ With Globe and Guard+ Reflector :+ White Coating Aluminum Reflector 10 150 60 95.0 15 180 65 80.0 20 150 70 90.0 25 140 75 25.0 30 160 80 15.0 35 145 85 5.0 40 130 90 0.0 45 135 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .64 .64 .64 .63 .63 .63 .60 .60 .60 .57 .57 .57 .55 .55 .55 .54 1 .57 .55 .54 .56 .54 .53 .54 .52 .51 .52 .51 .50 .50 .49 .48 .47 2 .52 .49 .46 .51 .48 .45 .49 .46 .44 .47 .45 .43 .45 .44 .42 .41 3 .46 .43 .40 .46 .42 .39 .44 .41 .39 .43 .40 .38 .41 .39 .38 .36 4 .42 .38 .35 .41 .38 .35 .40 .37 .34 .39 .36 .34 .38 .35 .33 .32 5 .38 .34 .31 .38 .34 .31 .37 .33 .30 .36 .33 .30 .35 .32 .30 .29 6 .35 .31 .28 .34 .30 .28 .34 .30 .27 .33 .30 .27 .32 .29 .27 .26 7 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .25 .29 .27 .24 .23 8 .30 .26 .23 .29 .25 .23 .29 .25 .23 .28 .25 .22 .27 .24 .22 .21 9 .28 .24 .21 .27 .23 .21 .27 .23 .21 .26 .23 .21 .26 .23 .21 .20 10 .26 .22 .19 .25 .22 .19 .25 .22 .19 .24 .21 .19 .24 .21 .19 .18
  • 5. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < VDY Pendant Type > < VDY 90° Bracket Type > < VDY Ceiling Type > < VDY 40° Bracket Type >
  • 6. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures SYL Series Wet Locations NEMA 3, 3R, 4, 7 Type of Explosion-proof < SYL > Increase Safety (Ex e II T1) Application SYL Series lighting fixtures are used ; in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operation conditions. Features Certification Standard Materials The globe frame is cast in one piece with guard. The globe is sealed into the globe frame firmly with synthetic rubber gaskets, and the globe assembly is fitted to the body by three socket head captive screws. All joint of lamp housing, including the joint between the top body and the terminal plate, are sealed up with high quality gaskets so as to restrict breathing. Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Enclosure : Aluminium sheet Globe : Heat resistant hard glass Globe Frame : Die casting aluminium Mounting Box : Cast aluminium alloy External Hardware : Stainless steel Compliance Standard Finish NEMA 3 ,3R, 4, 7 IEC 60079-0, 1 IP55 MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data WeightElectrical Rating Rated Voltage AC110V/ 220V/ 240V/ DC110V Mounting Type Catalog No. Weight Rated Wattage 100W/ 200W Ceiling SYL 2105 3.9 Kg Entry Size 1/2", 3/4", 1" If you need more information, contact us please.⇨
  • 7. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <SYL 2205> 0 137.0 50 132.7 5 143.4 55 149.8 Lamp : IL200 (2920 lm)+ With Globe and Guard+ 10 149.8 60 102.7 15 128.4 65 98.5 20 134.9 70 34.2 25 137.0 75 15.0 30 107.0 80 6.4 35 107.0 85 4.3 40 102.7 90 2.2 45 111.3 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .62 .62 .62 .60 .60 .60 .58 .58 .58 .55 .55 .55 .53 .53 .53 .52 1 .55 .53 .51 .54 .52 .51 .52 .50 .49 .50 .49 .47 .48 .47 .46 .45 2 .49 .46 .44 .48 .45 .43 .46 .44 .42 .45 .43 .41 .43 .42 .40 .39 3 .44 .40 .37 .43 .40 .37 .42 .39 .36 .40 .38 .36 .39 .37 .35 .34 4 .40 .35 .32 .39 .35 .32 .38 .34 .32 .36 .34 .31 .35 .33 .31 .30 5 .36 .31 .28 .35 .31 .28 .34 .31 .28 .33 .30 .28 .32 .29 .27 .26 6 .32 .28 .25 .32 .28 .25 .31 .27 .25 .30 .27 .24 .29 .26 .24 .23 7 .29 .25 .22 .29 .25 .22 .28 .25 .22 .28 .24 .22 .27 .24 .22 .21 8 .27 .23 .20 .27 .23 .20 .26 .22 .20 .25 .22 .20 .25 .22 .20 .19 9 .25 .21 .18 .25 .21 .18 .24 .21 .18 .23 .20 .18 .23 .20 .18 .17 10 .23 .19 .17 .23 .19 .17 .22 .19 .17 .22 .19 .16 .21 .18 .16 .16 Ordering Number Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket Certification Incandescent Lamp 100 1/2" SYL 1105 SYL 2105 SYL 3105 SYL 4105 Ex e II T1 3/4" SYL 1103 SYL 2103 SYL 3103 SYL 4103 200 1/2" SYL 1205 SYL 2205 SYL 3205 SYL 4205 3/4" SYL 1203 SYL 2203 SYL 3203 SYL 4203 Ordering Information S Y L 1 1 0 5 ① ② ③ ④ SYL Lighting Fixture① ② Mounting Type Lamp Wattage (W)③ Entry Size④ 1 - Pendant 10 - 100 1 - 1" 2 - Ceiling 20 - 200 3 - 3/4" 3 - 90° Bracket 5 - 1/2" 4 - 40° Bracket
  • 8. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < SYL Ceiling Type > < SYL Pendant Type > < SYL 90° Bracket Type > < SYL 40° Bracket Type >
  • 9. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures EML Series Wet Locations NEMA 3, 3R, 7 <EML 8024> Type of Explosion-proof Flameproof (Ex d IIB T3) Application EML Series incandescent lighting fixtures are used ; for flush or surface mounting on ceiling, wall or pedant in conduit systems. in hazardous areas, both indoors and outdoors where enclosed and gasketed fixtures are required. in tunnels, building entrances and similar locations, where moisture, dirt, chemicals, vibration or rough usage are a problem. where ignitable concentrations of flammable gases, vapors, liquids or dusts can exist some of the time under normal operating conditions. Features Designed to exclude dirt, moisture and corrosive vapors from the interior of the fixtures and the conduit system. The globe-guard assembly in installed and removed as a unit making it necessary to handle only one piece in relamping. All fixtures are rugged and corrosion-resistant. Standard Materials Enclosure : Cast aluminium alloy Globe : Heat resistant hard glass Globe Ring : Cast aluminium alloy Guard : Stainless steel wire Compliance IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Certification Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Weight Mounting Type Catalog No. Weight Ceiling EML 8024 4.7 Kg Standard Finish Technical Data MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Electrical Rating Rated Voltage AC110V/ 220V/ 240V DC110V Rated Wattage 100W/ 150W/ 200W/ 300W Options Entry Size 1/2", 3/4", 1" Guard : Stainless steel Reflector : Aluminium Dome Reflector Aluminium 30° Angle Reflector Pole type pendant * Atmosphere Temp : -20 ~ 55℃ ℃ Ordering Number Lamp Watt Pendant Ceiling Bracket Certification Incandescent Lamp 100 EML 8011 EML 8021 EML 8031 Ex d IIB T3 150 EML 8014 EML 8024 EML 8034 200 EML 8012 EML 8022 EML 8032 300 EML 8013 EML 8023 EML 8033 * For Pole type, see pole section (1L-19) If you need more information, contact us please.⇨
  • 10. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <EML 8021> 0 75 50 130 5 76 55 132 Lamp : IL100 (1250 lm)+ With Globe and+ without Guard 10 80 60 139 15 88 65 143 20 92 70 147 25 101 75 151 30 111 80 150 35 118 85 150 40 126 90 150 45 129 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .88 .88 .88 .86 .86 .86 .82 .82 .82 .78 .78 .78 .75 .75 .75 .74 1 .74 .70 .66 .72 .68 .65 .69 .66 .63 .66 .63 .61 .63 .61 .59 .57 2 .62 .55 .50 .60 .54 .49 .57 .52 .48 .55 .51 .47 .52 .49 .46 .44 3 .52 .45 .39 .51 .44 .39 .49 .43 .38 .47 .42 .37 .45 .40 .37 .35 4 .45 .38 .32 .44 .37 .32 .42 .36 .31 .40 .35 .31 .39 .34 .30 .28 5 .40 .32 .27 .39 .32 .26 .37 .31 .26 .36 .30 .26 .34 .29 .25 .24 6 .35 .28 .23 .35 .28 .23 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20 7 .32 .25 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .17 8 .29 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .26 .21 .17 .15 9 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .24 .19 .15 .14 10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19 Dimension <EML Ceiling Type> < EML Pendant Type > < EML Bracket Type>
  • 11. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures EUL Series Wet Locations Factory Sealed NEMA 3, 3R, 7 Type of Explosion-proof Flameproof (Ex d IIB T3) <EUL 3021> Features The body is cast in one piece, and the upper part of which forms a terminal chamber. Globe assembly is securely hinged to the body. Mounting box has four-way conduit entries and a large access cover for wiring. The globe holder is fixed to the base of the body with special flameproof and weatherproof flanged joint. The guard is so constructed that can be hinged down for cleaning the globe. Application EUL Series lighting fixtures are used ; in tunnels, building entrances and similar locations where moisture, dirt, chemicals or rough usage are a problem. in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in areas where combustible dusts and flammable vapors are present simultaneously. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. where high light output is needed but space is limited. where ignitable concentrations of flammable gases, vapors, liquids or dusts can exist some of the time under normal operating conditions. Compliance IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Certification Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Standard Materials Standard Finish Enclosure : Die casting aluminium Globe : Heat resistant hard glass Inner Reflector : High purity aluminium External Hardware : Stainless steel Mounting Box : Cast aluminium alloy MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EUL 3022 3.7 ㎏ Rated Wattage 100W/ 200W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" If you need more information, contact us please.⇨
  • 12. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification Incandescent Lamp 100 EUL 3011 EUL 3021 EUL 3031 EUL 3041 Ex d IIB T3 200 EUL 3012 EUL 3022 EUL 3032 EUL 3042 * For Pole type, see pole section (1L-19) Ordering Information Temperature Performance Data E U L 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition ① ② ③ Type Watt. Temp ( )℃ "d" "DP" EUL Lighting Fixture① Mounting Type② Incandescent 100 40 T4 11 1 - Pendant 55 T3 - Wattage (W)③ 2 - Ceiling 200 40 T4 11 1 - 100 3 - 90° Bracket 55 T3 - 2 - 200 4 - 40° Bracket Dimension <Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
  • 13. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle /1000㏅ ㏐ Angle /1000㏅ ㏐ <EUL 3021> 0 167 50 133 5 180 55 132 Lamp : IL100 (1250lm)+ With Guard+ 10 138 60 158 15 140 65 119 20 136 70 120 25 146 75 107 30 175 80 91.8 35 171 85 27.7 40 162 90 10.1 45 153 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .87 .87 .87 .85 .85 .85 .81 .81 .81 .78 .78 .78 .75 .75 .75 .73 1 .76 .73 .70 .74 .71 .69 .71 .69 .67 .68 .66 .65 .66 .64 .63 .61 2 .67 .62 .57 .65 .61 .57 .63 .59 .55 .60 .57 .54 .58 .55 .53 .51 3 .59 .53 .48 .57 .52 .47 .55 .50 .47 .53 .49 .46 .51 .48 .45 .43 4 .52 .46 .41 .51 .45 .40 .49 .44 .40 .47 .43 .39 .46 .42 .39 .37 5 .46 .40 .35 .46 .39 .35 .44 .39 .35 .43 .38 .34 .41 .37 .34 .32 6 .42 .35 .31 .41 .35 .31 .40 .34 .30 .39 .34 .30 .38 .33 .30 .28 7 .38 .32 .27 .38 .32 .27 .36 .31 .27 .35 .30 .27 .34 .30 .27 .25 8 .35 .29 .25 .34 .29 .24 .33 .28 .24 .33 .28 .24 .32 .27 .24 .23 9 .32 .26 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .29 .25 .22 .21 10 .30 .24 .20 .29 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19 Angle /1000㏅ ㏐ Angle /1000㏅ ㏐ <EUL 3022> 0 172 50 83.8 5 157 55 85.3Lamp : IL200 (2920lm)+ With Guard+ 10 166 60 70.7 15 152 65 82.1 20 138 70 92.5 25 143 75 84.6 30 127 80 78.3 35 103 85 79.2 40 92.5 90 95.4 45 87.9 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .70 .70 .70 .69 .69 .69 .66 .66 .66 .63 .63 .63 .60 .60 .60 .59 1 .60 .57 .54 .59 .56 .54 .56 .54 .52 .54 .52 .50 .52 .50 .49 .47 2 .52 .47 .43 .50 .46 .43 .48 .45 .42 .46 .43 .41 .44 .42 .40 .38 3 .45 .40 .36 .44 .39 .35 .42 .38 .35 .41 .37 .34 .39 .36 .33 .32 4 .40 .34 .30 .39 .34 .30 .38 .33 .30 .36 .32 .29 .35 .32 .29 .27 5 .36 .30 .26 .35 .30 .26 .34 .29 .26 .33 .29 .26 .32 .28 .25 .24 6 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .23 .21 7 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .27 .23 .20 .19 8 .28 .23 .19 .27 .22 .19 .26 .22 .19 .26 .22 .19 .25 .21 .19 .18 9 .26 .21 .18 .25 .21 .17 .25 .20 .17 .24 .20 .17 .23 .20 .17 .16 10 .24 .19 .16 .24 .19 .16 .23 .19 .16 .23 .19 .16 .22 .19 .16 .15
  • 14. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent / Compact Fluorescent Lighting Fixtures EULS Series Wet Locations Factory Sealed NEMA 3, 3R, 7 Type of Explosion-proof Flameproof (Ex d IIB T4) Dust Ignition-proof (Ex DP II 12 IP55) Application Features EULS Series lighting fixtures are used ; in tunnels, building entrances and similar locations where moisture, dirt, chemicals or rough usage are a problem. in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in areas where combustible dusts and flammable vapors are present simultaneously. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. where high light output is needed but space is limited. where ignitable concentrations of flammable gases, vapors, liquids or dusts can exist some of the time under normal operating conditions. < EULS > Globe assembly is securely hinged to the body. Mounting box has four-way conduit entries and a large access opening cover for wiring. Standard Materials Enclosure : Die casting aluminium Globe : Heat resistant hard glass Inner Reflector : High purity aluminium External Hardware : Stainless steel Mounting Box : Cast aluminium alloy Compliance & Certification Standard Finish Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. IEC 60079- 0.1 NENA 3.3R.7 MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling EULS 3021 2.8 ㎏ Rated Wattage IL 100W/ CFL 20W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" If you need more information, contact us please.⇨
  • 15. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification Incandescent Lamp 100 EULS 3021 Ex d IIB T4 Compact Self Ballast Fluorescent Lamp 20 EULS 3022 Ex DP II 12 * Pendant , 90° and 40° Bracket types are order-made items. Ordering Information Temperature Performance Data E U L S 3 0 2 1 Lamp Ambient Flameproof Dust-Ignition ① ② ③ ④ Type Watt. Temp ( )℃ "d" "DP" , EULS Lighting Fixture① ② Watt④ Incandescent 100 40 T4 - 0 - 20 55 - - Mounting Type③ 1 - 100 Compact Fluorescent 20 40 T5 12 1 - Pendant 55 - - 2 - Ceiling 3 - 90° Bracket 4 - 40° Bracket Photometric Data Angle cd/1000 lm Angle cd/1000 lm <EULS 3021> 0 124 50 109 5 108 55 139Lamp : IL 100 (1250 )+ ㏐ With Globe and Guard+ 10 96.5 60 131 15 128 65 123 20 126 70 128 25 124 75 107 30 118 80 66.8 35 111 85 19.6 40 128 90 10.8 45 124 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .77 .77 .77 .76 .76 .76 .72 .72 .72 .69 .69 .69 .66 .66 .66 .65 1 .68 .65 .63 .66 .64 .62 .64 .61 .60 .61 .59 .58 .59 .57 .56 .55 2 .59 .55 .51 .58 .54 .50 .55 .52 .49 .53 .50 .48 .51 .49 .47 .45 3 .52 .46 .42 .51 .46 .42 .49 .44 .41 .47 .43 .40 .45 .42 .39 .38 4 .45 .40 .35 .45 .39 .35 .43 .38 .34 .41 .37 .34 .40 .36 .34 .32 5 .40 .35 .30 .40 .34 .30 .38 .33 .30 .37 .33 .29 .36 .32 .29 .28 6 .36 .30 .26 .36 .30 .26 .35 .30 .26 .33 .29 .26 .32 .28 .25 .24 7 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .29 .25 .22 .21 8 .30 .24 .21 .30 .24 .20 .29 .24 .20 .28 .23 .20 .27 .23 .20 .19 9 .28 .22 .19 .27 .22 .18 .26 .22 .18 .26 .21 .18 .25 .21 .18 .17 10 .26 .20 .17 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .15
  • 16. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Angle cd/1000 lm Angle cd/1000 lm <EULS 3022> 0 47.8 50 94.2 5 48.5 55 97.7 Lamp : CFL20 (1200 )+ ㏐ With Globe and Guard+ 10 49.3 60 99.9 15 51.3 65 101 20 56.3 70 102 25 61.8 75 101 30 70.3 80 98.4 35 78.0 85 94.2 40 83.7 90 90.7 45 89.4 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .57 .57 .57 .56 1 .56 .54 .51 .55 .52 .50 .53 .50 .48 .50 .49 .47 .48 .47 .45 .44 2 .47 .43 .39 .46 .42 .38 .44 .40 .37 .42 .39 .36 .40 .38 .35 .34 3 .40 .35 .30 .39 .34 .30 .37 .33 .29 .36 .32 .29 .34 .31 .28 .27 4 .35 .29 .24 .34 .29 .24 .32 .28 .24 .31 .27 .24 .30 .26 .23 .22 5 .30 .25 .20 .30 .24 .20 .29 .24 .20 .27 .23 .20 .26 .22 .19 .18 6 .27 .21 .17 .27 .21 .17 .25 .21 .17 .24 .20 .17 .23 .20 .17 .15 7 .24 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .21 .17 .14 .13 8 .22 .17 .13 .22 .17 .13 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12 9 .20 .15 .12 .20 .15 .12 .19 .15 .11 .18 .14 .11 .18 14 .11 .10 10 .18 .14 .10 .18 .13 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09 Dimension < Ceiling Type>
  • 17. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures EFL Series Wet Locations Factory Sealed NEMA 3, 3R, 7 Type of Explosion-proof Class I Division 1,2 Group C,D Flameproof (Ex d IIC T3) Features Application <EFL 6021> Factory sealed - no external seal required Easy to assemble and relamping Light weight Corrosion resistant Inner reflector eliminates upward spill light EFL Series lighting fixtures are used ; in locations which are hazardous due to the presence of flammable vapors or gases and where dampness or corrosion are present. as pendant, ceiling, wall bracket or bulkhead fixtures, indoor for general area or room lighting and outdoor for spot lighting. Standard Materials Enclosure : Die casting aluminium Globe : Heat resistant hard glass Inner Reflector : Extra pure aluminium Guard : Die casting aluminium Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Certification Compliance UL Listed File No. E 131747 Certified by UL (Underwriters Laboratories Inc.), KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. NEC - Class I Division 1,2 Group C,D, UL 844 - Lighting Fixtures for Use in Hazardous (Classified) Locations IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage Max. 240V (120V/ 220V for UL Listed) Pendant EFL 6011 5.3 ㎏ Rated Wattage 100W/ 200W/ 300W Ceiling EFL 6021 5.2 ㎏ Rated Frequency 50Hz/ 60Hz Bulkhead EFL 6043 7.3 ㎏ Entry Size 1/2", 3/4", 1" Bracket EFL 6033 8.1 ㎏ Ordering Number Lamp Watt Pendant Ceiling Bracket Bulkhead Certification Incandescent 100 EFL 6011 EFL 6021 EFL 6031 EFL 6041 Class I Division 1,2 Group C,D Ex d IIC T3 200 EFL 6012 EFL 6022 EFL 6032 EFL 6042 300 EFL 6013 EFL 6023 EFL 6033 EFL 6043 If you need more information, contact us please⇨
  • 18. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Information Temperature Performance Data E F L 6 0 1 1 Lamp Ambient Class I Flameproof ① ② ③ ④ Type Watt. Temp ( )℃ Group C,D "d" Incandes cent 100 40 120 (T4A) T3 EFL Lighting Fixture① Mounting Type③ Watt④ 55 - - 1 - Pendant 1 - 100 200 40 160(T3C) / 120(T4A)* T3 Lamp Type② 2 - Ceiling 2 - 200 55 - - 60 - Incandescent 3 - Bracket 3 - 300 300 40 160 (T3C) T3 4 - Bulkhead 55 - - * are when use 300W body Dimension <Ceiling Type> <Bracket Type> <Bulkhead Type> <Pendant Type> Photometric Data Angle cd/1000 lm Angle cd/1000 lm <EFL 6013> 0 124 50 86.8 5 118 55 92.7Lamp : IL300 (4278 lm)+ With Guard+ 10 112 60 94.6 15 108 65 98.6 20 96.7 70 104 25 90.7 75 86.8 30 80.9 80 82.9 35 74.9 85 80.9 40 73.0 90 78.8 45 77.0 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .66 .66 .66 .64 .64 .64 .61 .61 .61 .59 .59 .59 .56 .56 .56 .55 1 .56 .53 .50 .54 .52 .49 .52 .50 .48 .50 .48 .46 .48 .46 .45 .44 2 .47 .43 .39 .46 .42 .38 .44 .41 .38 .42 .39 .37 .40 .38 .36 .34 3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .36 .33 .30 .35 .32 .29 .28 4 .35 .30 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .31 .27 .25 .23 5 .31 .26 .22 .31 .26 .22 .30 .25 .22 .28 .24 .21 .27 .24 .21 .20 6 .28 .23 .19 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .18 .17 7 .26 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .16 .23 .19 .16 .15 8 .23 .18 .15 .23 .18 .15 .22 .18 .15 .22 .18 .15 .21 .17 .15 .14 9 .22 .17 .14 .21 .17 .14 .21 .16 .13 .20 .16 .13 .19 .16 .13 .12 10 .20 .15 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .18 .15 .12 .11
  • 19. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Compact Fluorescent Lighting Fixtures EFL Series Wet Locations Factory Sealed NEMA 3, 3R, 7 Type of Explosion-proof Flameproof (Ex d IIC T5) <EFL 7014> Features Factory sealed - no external seal required Easy to assemble and relamping Light weight Corrosion resistant Inner reflector eliminates upward spill light Use compact fluorescent lamp 20W instead of incandescent lamp. Application EFL Series lighting fixtures are used ; in locations which are hazardous due to the presence of flammable vapors or gases and where dampness or corrosion are present. as pendant, ceiling, wall bracket or bulkhead fixtures, indoor for general area or room lighting and outdoor for spot lighting. Standard Materials Enclosure : Die casting aluminium Globe : Heat resistant hard glass Inner Reflector : Extra pure aluminium Guard : Die casting aluminium Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Certification Compliance Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS(Korea Gas Safety Corporation), and the others. IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage Max. AC240V Pendant EFL 7014 5.3 ㎏ Rated Wattage Compact Fluorescent 20W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" Ordering Number Lamp Watt Pendant Ceiling Bracket Bulkhead Certification Compact Fluorescent 20 EFL 7014 EFL 7024 EFL 7034 EFL 7044 Ex d IIC T5 If you need more information, contact us please.⇨
  • 20. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Information Temperature Performance Data E F L 7 0 1 4 Lamp Ambient Flameproof ① ② ③ ④ Type Watt. Temp ( )℃ "d" Compact Fluorescent 20 40 T5 EFL Lighting Fixture① Mounting Type③ Watt : 4 - 20④ 55 - 1 - Pendant Lamp Type② 2 - Ceiling 70 - Compact Fluorescent 3 - Bracket 4 - Bulkhead Dimension <Ceiling Type> <Bracket Type> <Bulkhead Type> <Pendant Type> Photometric Data Angle cd/1000 lm Angle cd/1000 lm 0 63.3 50 86.5<EFL 7014> 5 63.3 55 92.2 Lamp : CFL20 (1200 lm)+ With Guard+ 10 64.0 60 98.4 15 65.3 65 101 20 71.8 70 104 25 78.7 75 108 30 80.2 80 104 35 78.0 85 99.9 40 76.7 90 92.9 45 80.2 ▞Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .69 .69 .69 .67 .67 .67 .64 .64 .64 .62 .62 .62 .59 .59 .59 .58 1 .58 .55 .52 .57 .54 .51 .54 .52 .50 .52 .50 .48 .50 .48 .47 .45 2 .48 .44 .39 .47 .43 .39 .45 .41 .38 .43 .40 .37 .41 .39 .36 .35 3 .41 .35 .31 .40 .35 .31 .38 .34 .30 .37 .33 .29 .35 .32 .29 .27 4 .36 .30 .25 .35 .29 .25 .33 .28 .25 .32 .28 .24 .30 .27 .24 .22 5 .31 .25 .21 .31 .25 .21 .29 .24 .21 .28 .24 .20 .27 .23 .20 .19 6 .28 .22 .18 .27 .22 .18 .26 .21 .18 .25 .21 .17 .24 .20 .17 .16 7 .25 .20 .16 .25 .19 .15 .24 .19 .15 .23 .18 .15 .22 .18 .15 .14 8 .23 .17 .14 .22 .17 .14 .22 .17 .14 .21 .17 .13 .20 .16 .13 .12 9 .21 .16 .12 .21 .16 .12 .20 .15 .12 .19 .15 .12 .19 .15 .12 .11 10 .19 .14 .11 .19 .14 .11 .18 .14 .11 .18 .14 .11 .17 .14 .11 .10
  • 21. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Incandescent Lighting Fixtures Pole Type Explosion proof & Vaportight Weathertight NEMA 3, 3R, 5 Lighting Fixtures Construction Lamp Watt Catalog Number Hand Rail Type Pedestal Type 2.5M Height 3.5M Height 2.5M Height 3.5M Height EFLP Series Flameproof Ex d IIB T3 CL I, GR C,D 60 EFLP 60906-25H EFLP 60906-35H EFLP 60906-25P EFLP 60906-35P 100 EFLP 60910-25H EFLP 60910-25H EFLP 60910-25H EFLP 60910-35H 200 EFLP 60920-25H EFLP 60920-25H EFLP 60920-25H EFLP 60920-35H EULP Series Flameproof Ex d IIB T4 60 EULP 30906-25H EULP 30906-35H EULP 30906-25P EULP 30906-35P 100 EULP 30910-25H EULP 30910-35H EULP 30910-25H EULP 30910-35H 200 EULP 30920-25H EULP 30920-35H EULP 30920-25H EULP 30920-35H SYLP Series Increased Safety Ex e II T1 60 SYLP 70906-25H SYLP 70906-35H SYLP 70906-25P SYLP 70906-35P 100 SYLP 70910-25H SYLP 70910-35H SYLP 70910-25P SYLP 70910-35P 200 SYLP 70920-25H SYLP 70920-35H SYLP 70920-25P SYLP 70920-35P VDYP Series Vapor Tight IP 54 60 VDYP 10906-25H VDYP 10906-35H VDYP 10906-25P VDYP 10906-35P 100 VDYP 10910-25H VDYP 10910-35H VDYP 10910-25P VDYP 10910-35P 200 VDYP 10920-25H VDYP 10920-35H VDYP 10920-25P VDYP 10920-35P Features These pole type fittings are the combinations of lighting units for Flameproof EFLP, EULP series, Increase safety SYLP series or Vapor tight VDYP series incandescent lighting fittings and goose neck shaped poles. These fittings are mainly used for tower illumination of chemical plant. Additionally, fixing and wiring connection of these fittings are recommended to be done with Flameproof EOB or Increased safety and Heavy duty SBD junction boxes in compliance with the type of protection of lighting units. Other height not listed in the catalog are also available on request. Conduit entry-Three(3)-28(1")max. Specify the position and size when ordering. If you need more information, contact us please.⇨
  • 22. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < Hand Rail Type > * Length (L) is order made. (Standard is 2.5M, 3.5M. See front page) < Pedestal Type >
  • 23. SECTION - 2L HID Lighting Fixture
  • 24. SECTION 2L H.I.D Lighting Fixtures INDEX Model Lamp Type / Watt. Certification for Explosion-proof PAGEHigh Pressure Sodium Mercury Vapor Metal Halide 50 70 100 150 200 250 400 100 200 250 400 100 175 250 400 IEC UL VD ● ● ● ● ● ● ● ● 2L - 1 VS ● ● ● ● ● ● ● ● ● ● ● ● ● 2L - 4 SR ● ● ● ● ● ● ● ● ● ● ● ● ● Ex nR II T3 2L - 7 VG ● ● ● ● ● Ex nR II T4 IP66 Ex DP II 11 Class I Division 2 Group A,B,C,D Class II Division 1,2 Group E,F,G Class III Division 1 2L - 12 VN ● ● ● ● ● ● ● 2L - 15 VZ ● ● ● ● ● ● 2L - 19 AUXILIARY H.I.D AUXILIARY LIGHTING 2L - 23 EVN ● ● ● ● ● ● ● Ex dnR IIC T4 Ex nR II T4 IP66 Ex DP II 11 IP66 2L - 24 EU ● ● ● ● ● Ex d IIB T4 Ex DP II 12 2L - 30 EA ● ● ● ● ● ● ● Ex d IIC T4 Ex d IIB T4 2L - 33 EVS ● ● ● ● ● ● ● ● ● ● Ex de IIC T3 2L - 39 EGS ● ● ● ● ● Ex d IIC T4 Ex DP II 12 2L - 43 EG ● ● ● ● ● ● ● ● ● ● Ex d IIC T3 Class I Division 1 Group C,D 2L - 46 POLE TYPE Flameproof, Increased Safety, Vaportight Pole Type 2L - 51 SB HID Ballast 2L - 53 Accessary Globe, Guard, Reflector 2L - 55
  • 25. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures VD Series Weathertight NEMA 3, 3R, 5 Application Features Standard Materials VD Series lighting fixtures are used ; in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment plants, offshore, dockside and other harbor installations as well as other heavy industrial applications. wherever the damaging effects of wind, snow, sleet, or hot sun are found. in marine applications where water spray and corrosive atmospheres are considerations. in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas. in Industrial areas, both indoors and outdoors where long life and low maintenance costs are desired. in industrial locations requiring elevated ambient capability. The lighting fixture has simple construction. The screwneck globe and the guard are screwed on to the body applying the reflector in its position by the guard. Synthetic rubber gasket is used between the body and globe, so that the lamp housing is sealed against vapors and dusts. Relamping is easily done by opening lower half of the guard and unscrewing the globe. H.I.D lighting fixture has external type ballast. Body : Die casting aluminium Globe : Heat resistant hard glass Reflector : White coating aluminium Mounting Box : Cast aluminium alloy Certification Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Compliance IP55 < VD > Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Ratings Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V/ DC110V Ceiling (Small) VDNY 32075 8.7 Kg Ceiling (Large) VDNY 32155 15.5 KgRated Wattage 70W/ 100W/ 150W/ 175W/ 200W Rated Frequency 50Hz/ 60Hz Entry Sizes 1/2", 3/4", 1" Also you can order various voltage :※ 120V/ 208V/ 277V/ 460V If you need more information, contact us please.⇨
  • 26. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket High Pressure Sodium 70 1/2" VDNY 31075 VDNY 32075 VDNY 33075 VDNY 34075 3/4" VDNY 31073 VDNY 32073 VDNY 33073 VDNY 34073 100 1/2" VDNY 31105 VDNY 32105 VDNY 33105 VDNY 34105 3/4" VDNY 31103 VDNY 32103 VDNY 33103 VDNY 34103 150 1/2" VDNY 31155 VDNY 32155 VDNY 33155 VDNY 34155 3/4" VDNY 31153 VDNY 32153 VDNY 33153 VDNY 34153 200 1/2" VDNY 31205 VDNY 32205 VDNY 33205 VDNY 34205 3/4" VDNY 31203 VDNY 32203 VDNY 33203 VDNY 34203 Metal Halide 100 1/2" VDHY 31105 VDHY 32105 VDHY 33105 VDHY 34105 3/4" VDHY 31103 VDHY 32103 VDHY 33103 VDHY 34103 175 1/2" VDHY 31175 VDHY 32175 VDHY 33175 VDHY 34175 3/4" VDHY 31173 VDHY 32173 VDHY 33173 VDHY 34173 Mercury Vapor 100 1/2" VDMY 31105 VDMY 32105 VDMY 33105 VDMY 34105 3/4" VDMY 31103 VDMY 32103 VDMY 33103 VDMY 34103 200 1/2" VDMY 31205 VDMY 32205 VDMY 33205 VDMY 34205 3/4" VDMY 31203 VDMY 32203 VDMY 33203 VDMY 34203 * For Pole type, see pole section (2L-51) Ordering Information V D N Y 3 1 0 7 5 ① ② ③ ④ ⑤ VDY Lighting Fixture① Mounting Type③ Lamp Wattage (W)④ Entry Size⑤ 31 - Pendant 07 - 70 1 - 1" Lamp Type② 32 - Ceiling 10 - 100 3 - 3/4" NY - High Pressure Sodium 33 - 90° Bracket 15 - 150 5 - 1/2" HY - Metal Halide 34 - 40° Bracket 17 - 175 MY - Mercury Vapour 20 - 200 ▞ Photometric Data Angle cd/1000 lm Angle cd/1000 lm <VDNY 32105> 0 160 50 132 5 132 55 132Lamp : NH100 (9000 lm)+ With Globe and Guard+ Reflector :+ White Coating Aluminum Reflector 10 132 60 132 15 146 65 125 20 160 70 125 25 153 75 111 30 146 80 83.3 35 139 85 27.8 40 139 90 6.9 45 132 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( ccρ ) 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .84 .84 .84 .82 .82 .82 .78 .78 .78 .75 .75 .75 .72 .72 .72 .70 1 .73 .70 .68 .72 .69 .66 .69 .66 .64 .66 .64 .62 .63 .62 .61 .59 2 .64 .59 .55 .63 .58 .54 .60 .56 .53 .58 .55 .52 .56 .53 .51 .49 3 .56 .50 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .49 .46 .43 .41 4 .50 .43 .39 .49 .43 .38 .47 .42 .38 .45 .41 .37 .44 .40 .37 .35 5 .44 .38 .33 .44 .38 .33 .42 .37 .33 .41 .36 .32 .39 .35 .32 .31 6 .40 .34 .29 .39 .33 .29 .38 .33 .29 .37 .32 .28 .36 .32 .28 .27 7 .36 .30 .26 .36 .30 .26 .35 .29 .26 .34 .29 .25 .33 .28 .25 .24 8 .33 .27 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .30 .26 .23 .21 9 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .28 .24 .21 .19 10 .28 .23 .19 .28 .23 .19 .27 .23 .19 .27 .22 .19 .26 .22 .19 .18
  • 27. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < VDY Ceiling Type > < VDY 40° Bracket Type > < VDY Pendant Type > < VDY 90° Bracket Type >
  • 28. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures VS Series Wet Locations NEMA 3, 3R Application < VS > VS Series lighting fixtures are used ; in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment plants, offshore, dockside and other harbor installations as well as other heavy industrial applications. in industrial areas, both indoors and outdoors where long life and low maintenance costs are desired. Features The lighting fixture has simple construction. Relamping is easily done by opening lower half of the guard and unscrewing the globe. H.I.D lighting fixture has external type ballast. Standard Materials Technical Data Body : Die casting aluminium Globe : Heat resistant hard glass External Hardware : Cast aluminium alloy Electrical Rating Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Rated Frequency 50Hz/ 60Hz Compliance Entry Size 1/2", 3/4", 1" IP55 NEMA 3, 3R Certification Also you can order various voltage :※ 120V/ 208V/ 277V/ 460V Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Standard Finish Weight Natural If you want another color, contact us please. Catalog No. Weight VSNL 7240 18.8 ㎏ Ordering Number Ordering Information Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket V S N L 7 1 1 5 ① ② ③ ④ ⑤ High Pressure Sodium 100 VSNL7110 VSNL7210 VSNL7310 VSNL7410 VS Lighting Fixture① 150 VSNL7115 VSNL7215 VSNL7315 VSNL7415 200 VSNL7120 VSNL7220 VSNL7320 VSNL7420 Lamp Type② 250 VSNL7125 VSNL7225 VSNL7325 VSNL7425 NL - High Pressure Sodium 400 VSNL7140 VSNL7240 VSNL7340 VSNL7440 HL - Metal Halide Metal Halide 100 VSHL7110 VSHL7210 VSHL7310 VSHL7410 ML - Mercury Vapour 175 VSHL7117 VSHL7217 VSHL7317 VSHL7417 250 VSHL7125 VSHL7225 VSHL7325 VSHL7425 Model Type③ Lamp Wattage (W)⑤ 400 VSHL7140 VSHL7240 VSHL7340 VSHL7440 7 - VS Type 10 - 100 Mercury Vapor 100 VSML7110 VSML7210 VSML7310 VSML7410 15 - 150 200 VSML7120 VSML7220 VSML7320 VSML7420 Mounting Type④ 17 - 175 250 VSML7125 VSML7225 VSML7325 VSML7425 1 - Pendant 20 - 200 300 VSML7130 VSML7230 VSML7330 VSML7430 2 - Ceiling 25 - 250 400 VSML7140 VSML7240 VSML7340 VSML7440 3 - 90° Bracket 30 - 300 * For Pole type, see pole section (2L-51) 4 - 40° Bracket 40 - 400 If you need more information, contact us please.⇨
  • 29. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <VSHL 7217> 0 169.6 50 187.5 5 165.2 55 205.4Lamp : MH175 (14000 lm)+ With Globe and without Guard+ 10 169.6 60 147.3 15 209.8 65 84.8 20 223.2 70 44.6 25 205.4 75 26.8 30 205.4 80 13.4 35 192.0 85 4.5 40 200.9 90 4.5 45 209.8 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .90 .90 .90 .88 .88 .88 .84 .84 .84 .80 .80 .80 .77 .77 .77 .76 1 .81 .78 .76 .79 .77 .74 .76 .74 .72 .73 .71 .70 .70 .69 .68 .66 2 .73 .69 .65 .71 .68 .64 .69 .66 .63 .66 .64 .61 .64 .62 .60 .59 3 .66 .60 .56 .64 .60 .56 .62 .58 .55 .60 .57 .54 .59 .56 .53 .52 4 .59 .54 .49 .58 .53 .49 .57 .52 .48 .55 .51 .48 .53 .50 .47 .46 5 .54 .48 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .49 .45 .42 .41 6 .49 .43 .39 .48 .43 .39 .47 .42 .39 .46 .42 .38 .45 .41 .38 .37 7 .45 .39 .35 .45 .39 .35 .43 .38 .35 .42 .38 .35 .41 .37 .34 .33 8 .42 .36 .32 .41 .36 .32 .40 .35 .32 .39 .35 .31 .38 .34 .31 .30 9 .38 .33 .29 .38 .33 .29 .37 .32 .29 .36 .32 .29 .36 .32 .29 .27 10 .36 .30 .27 .35 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25 Angle cd/1000 lm Angle cd/1000 lm <VSNL 7225> 0 302 50 158 5 288 55 155 Lamp : NH250 (25000 lm)+ With Globe and without+ Guard 10 235 60 142 15 210 65 108 20 182 70 72.5 25 162 75 47.5 30 165 80 27.5 35 160 85 15.0 40 152 90 7.5 45 155 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .83 .83 .83 .81 .81 .81 .77 .77 .77 .74 .74 .74 .71 .71 .71 .70 1 .73 .70 .67 .71 .69 .66 .68 .66 .64 .66 .64 .62 .63 .62 .60 .59 2 .65 .60 .57 .64 .60 .56 .61 .58 .55 .59 .56 .54 .57 .55 .52 .51 3 .58 .53 .49 .57 .52 .48 .55 .51 .47 .53 .49 .47 .51 .48 .46 .44 4 .52 .46 .42 .51 .46 .42 .49 .45 .41 .48 .44 .41 .46 .43 .40 .39 5 .47 .41 .37 .46 .41 .37 .45 .40 .37 .44 .39 .36 .42 .39 .36 .34 6 .43 .37 .33 .42 .37 .33 .41 .36 .33 .40 .36 .32 .39 .35 .32 .31 7 .39 .34 .30 .39 .33 .30 .38 .33 .29 .37 .32 .29 .36 .32 .29 .28 8 .36 .31 .27 .36 .30 .27 .35 .30 .27 .34 .30 .26 .33 .29 .26 .25 9 .34 .28 .25 .33 .28 .25 .32 .28 .24 .32 .27 .24 .31 .27 .24 .23 10 .31 .26 .23 .31 .26 .23 .30 .26 .22 .30 .25 .22 .29 .25 .22 .21
  • 30. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < VS Ceiling Type > < VS 40° Bracket Type > < VS Pendant Type > < VS 90° Bracket Type >
  • 31. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures SR Series Wet Locations NEMA 3, 3R, 4, 4X, 7 Type of Explosion-proof < SR > Non Sparking (Ex nR II T3) Application SR Series lighting fixtures are used ; in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operation conditions. Features Certification Standard Materials The globe frame is cast in one piece with guard. The globe is sealed into the globe frame firmly with synthetic rubber gaskets, and the globe assembly is fitted to the body by three socket head captive screws. All joint of lamp housing, including the joint between the top body and the terminal plate, are sealed up with high quality gaskets so as to restrict breathing. The body and ballast are constructed separately so as to protect the ballast from the heat of the lamp. Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Enclosure : Aluminium sheet Globe : Heat resistant hard glass Globe Frame : Die casting aluminium alloy Mounting Box : Cast aluminium alloy External Hardware : Stainless steelCompliance NEMA 3 ,3R, 4, 4X, 7 IEC 60079-0, 15 IP55 Standard Finish Options MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. With Choke or Lead Peak type Ballast Technical Data WeightElectrical Rating Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Enclosure Type Catalog No. Weight Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Small (Ceiling) SRHL 2105 10.3 Kg Entry Size 1/2", 3/4", 1" Middle (Ceiling) SRHL 2255 19.6 Kg If you need more information, contact us please.⇨
  • 32. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling 90° Bracket 40° Bracket Certification High Pressure Sodium 100 1/2" SRNL1105 SRNL2105 SRNL3105 SRNL4105 Ex nR II T3 3/4" SRNL1103 SRNL2103 SRNL3103 SRNL4103 150 1/2" SRNL1155 SRNL2155 SRNL3155 SRNL4155 3/4" SRNL1153 SRNL2153 SRNL3153 SRNL4153 200 1/2" SRNL1205 SRNL2205 SRNL3205 SRNL4205 3/4" SRNL1203 SRNL2203 SRNL3203 SRNL4203 250 1/2" SRNL1255 SRNL2255 SRNL3255 SRNL4255 3/4" SRNL1253 SRNL2253 SRNL3253 SRNL4253 400 1/2" SRNL1405 SRNL2405 SRNL3405 SRNL4405 3/4" SRNL1403 SRNL2403 SRNL3403 SRNL4403 Metal Halide 100 1/2" SRHL1105 SRHL2105 SRHL3105 SRHL4105 3/4" SRHL1103 SRHL2103 SRHL3103 SRHL4103 175 1/2" SRHL1175 SRHL2175 SRHL3175 SRHL4175 3/4" SRHL1173 SRHL2173 SRHL3173 SRHL4173 250 1/2" SRHL1255 SRHL2255 SRHL3255 SRHL4255 3/4" SRHL1253 SRHL2253 SRHL3253 SRHL4253 400 1/2" SRHL1405 SRHL2405 SRHL3405 SRHL4405 3/4" SRHL1403 SRHL2403 SRHL3403 SRHL4403 Mercury Vapor 100 1/2" SRML1105 SRML2105 SRML3105 SRML4105 3/4" SRML1103 SRML2103 SRML3103 SRML4103 200 1/2" SRML1205 SRML2205 SRML3205 SRML4205 3/4" SRML1203 SRML2203 SRML3203 SRML4203 250 1/2" SRML1255 SRML2255 SRML3255 SRML4255 3/4" SRML1253 SRML2253 SRML3253 SRML4253 400 1/2" SRML1405 SRML2405 SRML3405 SRML4405 3/4" SRML1403 SRML2403 SRML3403 SRML4403 * For Pole type, see pole section (2L-51) Ordering Information S R N L 1 1 0 5 ① ② ③ ④ ⑤ SR Lighting Fixture① ③ Mounting Type Lamp Wattage (W)④ Entry Size⑤ 1 - Pendant 10 - 100 1 - 1" Lamp Type② 2 - Ceiling 15 - 150 3 - 3/4" NL - High Pressure Sodium 3 - 90° Bracket 17 - 175 5 - 1/2" HL - Metal Halide 4 - 40° Bracket 20 - 200 ML - Mercury Vapour 25 - 250 40 - 400
  • 33. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <SRNL 2255> 0 170 50 130 5 118 55 102Lamp : NH250 (25000 lm)+ With Globe and Guard+ 10 128 60 80.0 15 152 65 50.0 20 175 70 25.0 25 170 75 12.5 30 158 80 7.5 35 148 85 5.0 40 145 90 2.5 45 142 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .59 .59 .59 .58 .58 .58 .55 .55 .55 .53 .53 .53 .51 .51 .51 .50 250 1 1 .53 .52 .50 .52 .51 .49 .50 .49 .48 .48 .47 .46 .46 .46 .45 .44 2 .48 .46 .43 .47 .45 .43 .46 .44 .42 .44 .42 .41 .43 .41 .40 .39 200 0.8 3 .44 .41 .38 .43 .40 .38 .42 .39 .37 .40 .38 .36 .39 .37 .36 .35 4 .40 .36 .34 .39 .36 .34 .38 .35 .33 .37 .35 .33 .36 .34 .32 .31 150 0.6 5 .37 .33 .30 .36 .33 .30 .35 .32 .30 .34 .32 .29 .33 .31 .29 .28 6 .34 .30 .27 .33 .30 .27 .32 .29 .27 .32 .29 .27 .31 .28 .27 .26 100 0.4 7 .31 .27 .25 .31 .27 .25 .30 .27 .25 .29 .26 .24 .29 .26 .24 .23 8 .29 .25 .23 .28 .25 .23 .28 .25 .22 .27 .24 .22 .27 .24 .22 .21 9 .27 .23 .21 .26 .23 .21 .26 .23 .21 .25 .23 .21 .25 .22 .21 .20 10 .25 .22 .19 .25 .21 .19 .24 .21 .19 .24 .21 .19 .23 .21 .19 .18 Angle cd/1000 lm Angle cd/1000 lm <SRHL2255> 0 203 50 220 5 168 55 204Lamp : MH250 (20500 lm)+ With Globe and Guard+ 10 156 60 137 15 143 65 57.9 20 152 70 27.4 25 174 75 12.2 30 213 80 6.1 35 238 85 3.0 40 229 90 3.0 45 229 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .86 .86 .86 .84 .84 .84 .80 .80 .80 .77 .77 .77 .74 .74 .74 .72 250 1 1 .77 .75 .72 .76 .73 .71 .73 .71 .69 .70 .68 .67 .67 .66 .65 .64 2 .70 .66 .63 .69 .65 .62 .66 .63 .61 .64 .61 .59 .62 .60 .58 .57 175 0.68 3 .63 .58 .55 .62 .58 .54 .60 .56 .53 .58 .55 .52 .56 .54 .51 .50 4 .57 .52 .48 .56 .51 .48 .55 .50 .47 .53 .49 .46 .52 .48 .46 .45 5 .52 .46 .42 .51 .46 .42 .50 .45 .42 .48 .45 .41 .47 .44 .41 .40 6 .47 .42 .38 .47 .41 .38 .46 .41 .37 .44 .40 .37 .43 .40 .37 .35 7 .43 .38 .34 .43 .38 .34 .42 .37 .34 .41 .37 .33 .40 .36 .33 .32 8 .40 .34 .31 .39 .34 .31 .38 .34 .30 .38 .33 .30 .37 .33 .30 .29 9 .37 .31 .28 .36 .31 .28 .36 .31 .28 .35 .31 .27 .34 .30 .27 .26 10 .34 .29 .25 .34 .29 .25 .33 .28 .25 .32 .28 .25 .32 .28 .25 .24
  • 34. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < SR 90° Bracket Type > < SR 40° Bracket Type > < SR Ceiling Type > < SR Pendant Type > LAMP WATT Ceiling Type Pendant Type 90° Bracket 40° Bracket A BØ A BØ A BØ A BØ C Max. 100W 550 275 310 275 420 275 650 275 345 Max. 250W 640 340 400 340 510 340 710 340 400 Max. 400W 695 385 455 385 565 385 750 385 430
  • 35. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 V Series H.I.D Lighting Fixtures VG, VN, VZ Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7 < VG > < VN > < VZ > Type of Explosion-proof Fixture Wattage Class I Division 2 Group A,B,C,D Class II Division 1,2 Group E,F,G Class III Division 1 Simultaneous Presence (VN Series) Non Sparking (Ex nR II T4 IP66) Dust Ignition-proof (Ex DP II 11) Lamp V Series Wattage Type VG VN VZ HPS 50, 70, 100 150, 200, 250 250, 400 MH 100 175, 250 250, 400 MV 100 200, 250 250, 400 Application in hazardous locations requiring elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems. Four mounting arrangements to suit any lighting layout pendant, ceiling, wall bracket and stanchion. Internal ballasts-separate ballasts are not required. High power factor (90%) ballasts reduce power costs allow more fixtures per circuit. Cast aluminium alloy construction and epoxy powder finish provide excellent resistant to corrosion. V Series HID lighting fixtures are used ; in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in petroleum refineries, chemical, petrochemical and other heavy process industry facilities. in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas. where ignitable concentrations of flammable gases, vapors or liquids can exist all of the time or some of the time under normal operation conditions. Features Hinged ballast housing for ease of installation and maintenance Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation. Factory sealed, porcelain with mogul or medium base socket. Dome and 30°angle reflectors made of FRP material won't rust, corrode, dent, chip or peel. If you need more data, contact us please.⇨
  • 36. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 V Series H.I.D Lighting Fixtures VG Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7 Type of Explosion-proof Non Sparking (Ex nR II T4 IP66) Class I Division 2 Group A,B,C,D Features Standard Materials Compact, lightweight design is ideal for medium and low mounting heights. Cast aluminium alloy construction and epoxy powder finish provide excellent resistant to corrosion. Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation. Restricted Breathing Construction : zone 2 only Enclosure : Die casting aluminium Globe : Heat resistant hard glass Lamp socket : Porcelain with screw shell Reflector : High grade aluminium sheet Guard : Die casting aluminium Compliance & Certification < VG > NEC - Class I Division 2 Group A,B,C,D UL 844 - Lighting Fixtures for Use in Hazardous (Classified) Locations UL Listed File No. E 131747 IEC 60079-0, 15 NEMA 3, 3R, 4, 4X, 7 Certified by UL (Underwriters Laboratories Inc.), KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Options With Dome Reflector or 30° Angle Reflector Instant Restrike (HPS only) Fused to protect ballast and capacitors Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V Ceiling VGNL 22103 7.7 ㎏ (110V/ 120V/ 208V/ 220V/ 240V/ 277V for UL Listed) Rated Wattage 50W/ 70W/ 100W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" If you need more information, contact us please.⇨
  • 37. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification High Pressure Sodium 50 1" VGNL 12051 VGNL 22051 VGNL 32051 VGNL 92051 Ex nR II T4 IP66 Class I Division 2 Group A,B,C,D 3/4" VGNL 12053 VGNL 22053 VGNL 32053 VGNL 92053 70 1" VGNL 12071 VGNL 22071 VGNL 32071 VGNL 92071 3/4" VGNL 12073 VGNL 22073 VGNL 32073 VGNL 92073 100 1" VGNL 12101 VGNL 22101 VGNL 32101 VGNL 92101 3/4" VGNL 12103 VGNL 22103 VGNL 32103 VGNL 92103 Metal Halide 100 1" VGHL 12101 VGHL 22101 VGHL 32101 VGHL 92101 Ex nR II T3 IP66 Class I Division 2 Group A,B,C,D 3/4" VGHL 12103 VGHL 22103 VGHL 32103 VGHL 92103 Mercury Vapor 100 1" VGML 12101 VGML 22101 VGML 32101 VGML 92101 3/4" VGML 12103 VGML 22103 VGML 32103 VGML 92103 Ordering Information Dimension <Bracket Type> <Stanchion Type> <Ceiling Type> <Pendant Type> V G N L 1 2 0 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦ VG Lighting Fixture① Lamp Wattage (W)⑤ 05 - 50 Lamp Type② 07 - 70 NL - High Pressure Sodium 10 - 100 HL - Metal Halide ML - Mercury Vapour Mounting Type③ Entry Size⑥ 1 - Pendant 1 - 1" 2 - Ceiling 3 - 3/4" 3 - Bracket 5 - 1/2" 9 - Stanchion Input Voltage (V)④ 1 - 120 Options⑦ 2 - 220 DR - Dome Type Reflector 3 - 110 AR - Angle Type Reflector 4 - 208 5 - 277 IR - Instant Restrike 6 - 240 FU - Fused Type 7 - 230 Temperature Performance Data Lamp Ambient Class I Non-Sparking Type Watt. Temp ( )℃ Div. 2 "nR" High Pressure Sodium 50 40 260 (T2B) T4 55 - T4 70 40 260 (T2B) T4 55 - T4 100 40 260 (T2B) T4 55 - T4 Metal Halide 100 40 - T3 55 - T3 Mercury Vapor 100 40 280 (T2A) T4 55 - T4
  • 38. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <VGNL 12101-DR> 0 78.7 50 262.4 5 77.8 55 239.1 Lamp : NH100 (9000 lm)+ With Guard+ Reflector :+ Aluminium Dome type Reflector 10 79.7 60 199.7 15 88.2 65 169.7 20 111.5 70 158.5 25 135.9 75 113.4 30 157.5 80 65.6 35 189.4 85 23.5 40 218.4 90 13.1 45 248.4 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77 1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62 100 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50 3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41 70 0.5 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34 5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29 50 0.25 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25 7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22 8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19 9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17 10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16 Angle cd/1000 lm Angle cd/1000 lm <VGHL 12101-DR> 0 90.9 50 199.9 5 90.9 55 164.8Lamp : MH100 (6500 lm)+ With Guard+ Reflector :+ Aluminium Dome type Reflector 10 94.8 60 144.0 15 114.2 65 132.4 20 133.7 70 48.1 25 177.8 75 27.3 30 218.0 80 16.9 35 266.1 85 11.7 40 266.1 90 9.0 45 245.3 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80 1 .86 .83 .80 .84 .81 .79 .81 .78 .77 .77 .76 .74 .75 .73 .72 .70 2 .77 .72 .68 .75 .71 .67 .72 .69 .66 .70 .67 .64 .68 .65 .63 .61 3 .69 .63 .59 .67 .62 .58 .62 .61 .57 .63 .59 .56 .61 .58 .55 .54 4 .62 .56 .51 .61 .55 .50 .59 .54 .50 .57 .53 .49 .55 .52 .49 .47 5 .56 .49 .44 .55 .49 .44 .53 .48 .44 .52 .47 .43 .50 .46 .43 .41 6 .50 .44 .39 .50 .44 .39 .48 .43 .39 .47 .42 .38 .46 .42 .38 .37 7 .46 .40 .35 .45 .39 .35 .44 .39 .35 .43 .38 .34 .42 .38 .34 .33 8 .42 .36 .31 .42 .35 .31 .41 .35 .31 .40 .35 .31 .39 .34 .31 .29 9 .39 .32 .28 .38 .32 .28 .37 .32 .28 .36 .32 .28 .36 .31 .28 .26 10 .36 .30 .26 .35 .30 .26 .35 .29 .26 .34 .29 .25 .33 .29 .25 .24
  • 39. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 V Series H.I.D Lighting Fixtures VN Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7,9 < VN > Type of Explosion-proof Non Sparking (Ex nR II T3 IP66) Dust Ignition-proof (Ex DP II 11) Class I Division 2 Group A,B,C,D Class II Division 1,2 Group E,F,G Class III Division 1 Features Compact, lightweight design is ideal for medium and low mounting heights. Wide range of light sources to meet specific lighting needs - High Pressure Sodium (HPS): 150, 200 and 250W, Mercury Vapour (MV): 200 and 250W, Metal Halide (MH): 175 and 250W. Restricted Breathing Construction : Zone 2 only Standard Materials Enclosure : Die casting aluminium Globe : Heat resistant hard glass Lamp socket : Porcelain with screw shell Reflector : Aluminium sheet / Fiberglass-Reinforced Polyester Guard : Stainless steel Certification Compliance Options UL Listed File No. E 131747 Certified by UL (Underwriters Laboratories Inc.), KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. NEC - Class I Division 2 Group A,B,C,D, / Class II Division 1,2 Group E,F,G / Class III Division 1 UL 844 - Lighting Fixtures for Use in Hazardous (Classified) Locations IEC 60079-0, 15 NEMA 3, 3R, 4, 4X, 7, 9 With Dome Reflector or 30° Angle Reflector Instant Restrike (HPS only) Fused to protect ballast and capacitors Quartz Auxiliary Lighting come to full brightness immediately (Non-hazardous location only)Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V (110V/ 120V/ 208V/ 220V/ 240V/ 277V for UL Listed) Pendant VNNL 12153 12.6 ㎏ Ceiling VNNL 22153 12.8 ㎏Rated Wattage 150W/ 175W/ 200W/ 250W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" If you need more information, contact us please.⇨
  • 40. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification High Pressure Sodium 150 1" VNNL 12151 VNNL 22151 VNNL 32151 VNNL 92151 Ex nR II T3 IP66 Ex DP II 11 3/4" VNNL 12153 VNNL 22153 VNNL 32153 VNNL 92153 200 1" VNNL 12201 VNNL 22201 VNNL 32201 VNNL 92201 3/4" VNNL 12203 VNNL 22203 VNNL 32203 VNNL 92203 250 1" VNNL 12251 VNNL 22251 VNNL 32251 VNNL 92251 3/4" VNNL 12253 VNNL 22253 VNNL 32253 VNNL 92253 Metal Halide 175 1" VNHL 12171 VNHL 22171 VNHL 32171 VNHL 92171 Ex nR II T3 IP66 Ex DP II 12 IP66 3/4" VNHL 12173 VNHL 22173 VNHL 32173 VNHL 92173 250 1" VNHL 12251 VNHL 22251 VNHL 32251 VNHL 92251 3/4" VNHL 12253 VNHL 22253 VNHL 32253 VNHL 92253 Mercury Vapor 200 1" VNML 12201 VNML 22201 VNML 32201 VNML 92201 Ex nR II T4 IP66 Ex DP II 11 3/4" VNML 12203 VNML 22203 VNML 32203 VNML 92203 250 1" VNML 12251 VNML 22251 VNML 32251 VNML 92251 3/4" VNML 12253 VNML 22253 VNML 32253 VNML 92253 Ordering Information V N N L 1 2 1 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦ VN Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④ NL - High Pressure Sodium 1 - Pendant 1 - 120 HL - Metal Halide 2 - Ceiling 2 - 220 ML - Mercury Vapour 3 - Bracket 3 - 110 9 - Stanchion 4 - 208 Lamp Wattage (W)⑤ : Entry Size⑥ Options⑦ 5 - 277 15 - 150 1 - 1" DR - Dome Type Reflector 6 - 240 17 - 175 3 - 3/4" AR - Angle Type Reflector 7 - 230 20 - 200 5 - 1/2" IR - Instant Restrike Type 25 - 250 FU - Fused Type QAL - Quartz Auxiliary Lighting Type Temperature Performance Data Lamp Ambient Class I Class II Non-Sparking Dust Ignition Type Watt. Temp ( )℃ Div. 2 Div. 1 "nR" Proof "DP" High Pressure Sodium 150 40 260 (T2B) 160 (T2C) T3 11 55 - - T3 - 200 40 260 (T2B) 160 (T2C) T3 11 55 - - T3 - 250 40 260 (T2B) 160 (T2C) T3 11 55 - - T3 - Metal Halide 175 40 - 160 (T2C) T3 11 55 - T3 - 250 40 300 (T2) 160 (T2C) T3 11 55 - - T3 - Mercury Vapor 200 40 325 (T1) 165 (T2B) T4 11 55 - - - - 250 40 325 (T1) 165 (T2B) T4 11 55 - - - -
  • 41. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <VNNL 12251-DR> 0 91.0 50 136 5 91.0 55 140Lamp : NH250 (25000 lm)+ With Guard+ Reflector :+ FRP Dome Reflector 10 91.0 60 140 15 107 65 140 20 123 70 143 25 130 75 136 30 130 80 110 35 127 85 68.3 40 130 90 22.8 45 133 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .91 .91 .91 .89 .89 .89 .85 .85 .85 .81 .81 .81 .78 .78 .78 .77 1 .78 .75 .72 .77 .73 .70 .73 .71 .68 .70 .68 .66 .68 .66 .64 .62 250 1 2 .67 .61 .57 .66 .60 .56 .63 .58 .55 .60 .57 .53 .58 .55 .52 .50 3 .58 .51 .46 .57 .50 .45 .54 .49 .44 .52 .48 .44 .50 .46 .43 .41 200 0.8 4 .51 .43 .38 .50 .43 .38 .48 .42 .37 .46 .41 .37 .44 .40 .36 .34 5 .45 .38 .32 .44 .37 .32 .42 .36 .32 .41 .35 .31 .39 .35 .31 .29 150 0.56 6 .40 .33 .28 .39 .33 .28 .38 .32 .27 .37 .31 .27 .35 .31 .27 .25 7 .36 .29 .24 .36 .29 .24 .34 .28 .24 .33 .28 .24 .32 .27 .24 .22 8 .33 .26 .22 .32 .26 .21 .31 .26 .21 .30 .25 .21 .30 .25 .21 .19 9 .30 .24 .19 .30 .24 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .17 10 .28 .22 .17 .28 .22 .17 .27 .21 .17 .26 .21 .17 .25 .21 .17 .16 Angle cd/1000 lm Angle cd/1000 lm <VNHL 12251-DR> 0 102 50 130 5 102 55 140Lamp : MH250 (20500 lm)+ With Guard+ Reflector :+ FRP Dome Reflector 10 98.2 60 144 15 119 65 144 20 133 70 144 25 133 75 144 30 137 80 130 35 133 85 59.6 40 140 90 10.5 45 126 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77 1 .79 .76 .73 .78 .74 .71 .74 .72 .69 .71 .69 .67 .68 .67 .65 .63 250 1 2 .68 .62 .58 .67 .61 .57 .64 .59 .55 .61 .57 .54 .59 .56 .53 .51 3 .59 .52 .47 .58 .51 .46 .55 .50 .45 .53 .48 .44 .51 .47 .44 .42 175 0.68 4 .52 .44 .39 .50 .44 .38 .48 .43 .38 .47 .41 .37 .45 .40 .37 .35 5 .46 .38 .33 .45 .38 .33 .43 .37 .32 .41 .36 .32 .40 .35 .31 .30 6 .41 .34 .28 .40 .33 .28 .39 .32 .28 .37 .32 .28 .36 .31 .27 .26 7 .37 .30 .25 .36 .29 .25 .35 .29 .24 .34 .28 .24 .33 .28 .24 .22 8 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .30 .25 .22 .20 9 .31 .24 .20 .30 .24 .20 .30 .24 .20 .29 .23 .20 .28 .23 .19 .18 10 .29 .22 .18 .28 .22 .18 .27 .22 .18 .27 .21 .18 .26 .21 .18 .16
  • 42. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < VN Bracket Type > < VN Stanchion Type > < VN Ceiling Type > < VN Pendant Type >
  • 43. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 V Series H.I.D Lighting Fixtures VZ Series Wet Locations Marine Locations NEMA 3,3R,4,4X,7,9 Type of Explosion-proof Non Sparking (Ex nR II T2 IP66) Class I Division 2 Group A,B,C,D Class II Division 1,2 Group E,F,G Class III Division 1 Features Standard Materials Low ambient capability to -40℃ Wide range of light sources to meet specific lighting needs - High Pressure Sodium (HPS): 250 and 400W, Mercury Vapour (MV): 250 and 400W, Metal Halide (MH): 250 and 400W Restricted Breathing Construction : Zone 2 only < VZ > Enclosure : Die casting aluminium Globe : Heat resistant hard glass Lamp socket : Porcelain with screw shell Reflector : Aluminium sheet / Fiberglass-Reinforced Polyester Guard : Stainless steel Certification UL Listed File No. E 131747 Certified by UL (Underwriters Laboratories Inc.), KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Options With Dome Reflector or 30° Angle Reflector Fused to protect ballast and capacitors Quartz Auxiliary Lighting come to full brightness immediately (Non-hazardous location only) Compliance NEC - Class I Division 2 Group A,B,C,D, / Class II Division 1,2 Group E,F,G / Class III Division 1 UL 844 - Lighting Fixtures for Use in Hazardous (Classified) Locations IEC 60079-0, 15 NEMA 3, 3R, 4, 4X, 7, 9 Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Bracket VZNL 32253 18.8 ㎏ Rated Wattage 250W/ 400W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" Also you can order various voltage :※ 120V/ 208V/ 277V/ 460V If you need more information, contact us please.⇨
  • 44. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification High Pressure Sodium 250 1" VZNL 12251 VZNL 22251 VZNL 32251 VZNL 92251 Ex nR II T3 3/4" VZNL 12253 VZNL 22253 VZNL 32253 VZNL 92253 400 1" VZNL 12401 VZNL 22401 VZNL 32401 VZNL 92401 Ex nR II T2 3/4" VZNL 12403 VZNL 22403 VZNL 32403 VZNL 92403 Metal Halide 250 1" VZHL 12251 VZHL 22251 VZHL 32251 VZHL 92251 Ex nR II T3 3/4" VZHL 12253 VZHL 22253 VZHL 32253 VZHL 92253 400 1" VZHL 12401 VZHL 22401 VZHL 32401 VZHL 92401 Ex nR II T2 3/4" VZHL 12403 VZHL 22403 VZHL 32403 VZHL 92403 Mercury Vapor 250 1" VZML 12251 VZML 22251 VZML 32251 VZML 92251 Ex nR II T3 3/4" VZML 12253 VZML 22253 VZML 32253 VZML 92253 400 1" VZML 12401 VZML 22401 VZML 32401 VZML 92401 Ex nR II T2 3/4" VZML 12403 VZML 22403 VZML 32403 VZML 92403 Ordering Information V Z N L 1 2 2 5 1 - DR ① ② ③ ④ ⑤ ⑥ ⑦ VZ Lighting Fixture① Lamp Type② Mounting Type③ Input Voltage (V)④ NL - High Pressure Sodium 1 - Pendant 1 - 120 HL - Metal Halide 2 - Ceiling 2 - 220 ML - Mercury Vapour 3 - Bracket 3 - 110 9 - Stanchion 4 - 208 5 - 277 Lamp Wattage (W)⑤ Entry Size⑥ Options⑦ 6 - 240 25 - 250 1 - 1" DR - Dome Type Reflector 7 - 230 40 - 400 3 - 3/4" AR - Angle Type Reflector 5 - 1/2" FU - Fused Type QAL - Quartz Auxiliary Lighting Type Temperature Performance Data Lamp Ambient Non Sparking Type Watt. Temp ( )℃ "nR" High Pressure Sodium 250 40 T3 55 T3 400 40 T2 55 T2 Metal Halide 250 40 T3 55 T3 400 40 T2 55 T2 Mercury Vapor 250 40 T3 55 T3 400 40 T2 55 T2
  • 45. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm 0 13.9 50 86.3<VZNL 22401-DR> 5 14.7 55 93.6 Lamp : NH400 (46000 lm)+ With Globe and without Guard+ Reflector :+ FRP Dome Reflector 10 15.7 60 92.5 15 27.5 65 97.2 20 36.7 70 100 25 40.4 75 104 30 45.0 80 104 35 50.6 85 106 40 70.1 90 106 45 77.9 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .63 .63 .63 .61 .61 .61 .58 .58 .58 .56 .56 .56 .54 .54 .54 .53 1 .52 .49 .47 .51 .48 .46 .49 .46 .44 .46 .45 .43 .44 .43 .42 .40 2 .43 .38 .34 .42 .38 .34 .40 .36 .33 .38 .35 .32 .36 .34 .31 .30 3 .36 .31 .26 .35 .30 .26 .33 .29 .25 .32 .28 .25 .30 .27 .24 .23 4 .31 .25 .21 .30 .25 .21 .29 .24 .20 .27 .23 .20 .26 .22 .20 .18 5 .27 .21 .17 .26 .21 .17 .25 .20 .17 .24 .20 .16 .23 .19 .16 .15 6 .24 .18 .14 .23 .18 .14 .22 .17 .14 .21 .17 .14 .20 .16 .13 .12 7 .21 .16 .12 .21 .15 .12 .20 .15 .12 .19 .15 .12 .18 .14 .11 .10 8 .19 .14 .10 .18 .14 .10 .18 .13 .10 .17 .13 .10 .16 .13 .10 .09 9 .17 .12 .09 .17 .12 .09 .16 .12 .09 .16 .12 .09 .15 .11 .09 .08 10 .16 .11 .08 .15 .11 .08 .15 .11 .08 .14 .10 .08 .14 .10 .08 .07 Angle cd/1000 lm Angle cd/1000 lm 0 19.3 50 115<VZHL 22401-DR> 5 20.7 55 111 Lamp : MH400 (34000 lm)+ With Globe and without Guard+ Reflector :+ FRP Dome Reflector 10 22.1 60 113 15 30.2 65 119 20 43.2 70 124 25 54.4 75 128 30 53.9 80 131 35 68.4 85 134 40 67.8 90 139 45 105 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .79 .79 .79 .77 .77 .77 .73 .73 .73 .70 .70 .70 .67 .67 .67 .66 1 .65 .62 .58 .64 .61 .58 .61 .58 .56 .58 .56 .54 .56 .54 .52 .51 2 .54 .48 .43 .53 .47 .43 .50 .46 .42 .48 .44 .41 .46 .42 .40 .38 3 .45 .38 .33 .44 .38 .33 .42 .37 .32 .40 .35 .31 .38 .34 .31 .29 4 .39 .32 .26 .38 .31 .26 .36 .30 .26 .34 .29 .25 .33 .28 .25 .23 5 .34 .27 .21 .33 .26 .21 .31 .25 .21 .30 .25 .21 .29 .24 .20 .19 6 .30 .23 .18 .29 .23 .18 .28 .22 .18 .27 .21 .17 .25 .21 .17 .16 7 .27 .20 .15 .26 .20 .15 .25 .19 .15 .24 .19 .15 .23 .18 .15 .13 8 .24 .17 .13 .23 .17 .13 .22 .17 .13 .22 .16 .13 .21 .16 .13 .11 9 .22 .16 .11 .21 .15 .11 .20 .15 .11 .20 .15 .11 .19 .14 .11 .10 10 .20 .14 .10 .19 .14 .10 .19 .14 .10 .18 .13 .10 .17 .13 .10 .09
  • 46. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < VZ Bracket Type > < VZ Ceiling Type > < VZ Stanchion Type > < VZ Pendant Type >
  • 47. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 V Series H.I.D Lighting Fixtures Auxiliary Lighting < Auxiliary Lighting > About Auxiliary Lighting Features V Series Auxiliary Lighting Momentary voltage outages or dips can temporarily extinguish HID lamps which may require up to ten minutes to restrike. To provide illumination during this period, 10~20% of the fixtures should be specified with auxiliary lighting. Hinged ballast housing for ease of installation and maintenance Hubs with integral conduit stop and bushing to help prevent damage to field wiring during installation. Factory sealed, porcelain with mogul or medium base socket. Four mounting arrangements to suit any lighting layout pendant, ceiling, wall bracket and stanchion. Internal ballasts-separate ballasts are not required. High power factor (90%) ballasts reduce power costs allow more fixtures per circuit. Cast aluminium alloy construction and epoxy powder finish provide excellent resistant to corrosion. Quartz auxiliary is available for all V Series fixtures (except those with plastic refractors) by adding the suffix QAL to the fixture catalog number. (Example : VN NL 1 2 15 1- QAL) Series VG fixtures with this option use 100 or 150 watt quartz lamps. Series VN wattage fixtures can use up to 250 watt quartz lamps. Quartz lamps are not supplied with the fixture Due to the quartz envelope surface temperature (exceeding 6000°C), fixtures with this option are not suitable for Wet hazardous locations. Contact the Factory for specific fixture suitabilities. Instant Restart Available for 70-150 Watt VG Series High Pressure Sodium Fixtures by adding Suffix "IR" to catalog number (Ex: VN NL 1 2 15 1 - IR). Additional instant restart interior circuitry may decrease High Pressure Sodium lamp life. Feature will not affect fixture suitability in hazardous location applications Incandescent Auxiliary With a surface lamp temperature lower than quartz, incandescent auxiliary lamps are available for Series V fixtures.
  • 48. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures EVN Series Wet Locations NEMA 3,3R,4,4X,7,9 Type of Explosion-proof Technical Data Flameproof-Non Sparking (Ex dnR IIC T4) Non Sparking (Ex nR II T4 IP66) Dust Ignition-proof (Ex DP II 11 IP66) Electrical Ratings Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Rated Wattage 50W/ 70W/ 100W/ 150W/ 175W/ 200W/ 250W Rated Frequency 50Hz/ 60Hz Weight Entry Sizes 1/2", 3/4", 1" Mounting Type Catalog No. Weight Also you can order various voltage :※ 120V/ 208V/ 277V/ 460V Pendant EVNNL 1255 11.5 Kg < EVN > Standard Finish Dark Gray If you want another color, contact us please. Certification Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Compliance IEC 60079-0, 1, 15 NEMA 3, 3R, 4, 4X, 7, 9 Options With Dome Reflector or 30° Angle Reflector with SMC or High Grade Aluminium With Choke or Lead Peak type Ballast For various voltage from 110V to 240V For 50Hz/ 60Hz Application Features EVN Series lighting fixtures are used ; in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment plants, offshore, dockside and other harbor installations as well as other heavy industrial applications. wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. in withstands the harshest of corrosive environments. to provide low wattage spot and floodlighting. where an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. where combustible dust, moisture, dirt are present and vibration, corrosion, rough usage are problems. Enclosure in glass fiber reinforced polyester resin, provide excellent resistant to corrosion so have a long life. Enclosure contain ultraviolet interception ingredient to resist transformation. Easy installation and maintenance. Pendant mounting module equipped with integral hub set screws for vibration resistance. Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. Grounding wire for safety. Hinged assembly allows the fixture to hang free during installation to permit the use of both hands when wiring. Standard Materials Housing, mounting modules, component pallets : Fiberglass reinforced polyester resin Globe : Heat resistant hard glass Gasket : Silicone rubber Reflector : Fiberglass Reinforced Polyester External Hardware : Stainless steel, Brass If you need more information, contact us please.⇨
  • 49. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification High Pressure Sodium 50 1/2" EVNNL 1055 EVNNL 2055 EVNNL 3055 EVNNL 9055 Ex dnR IIC T4 IP66 Ex nR II T4 IP66 Ex DP II 11 IP66 3/4" EVNNL 1053 EVNNL 2053 EVNNL 3053 EVNNL 9053 70 1/2" EVNNL 1075 EVNNL 2075 EVNNL 3075 EVNNL 9075 3/4" EVNNL 1073 EVNNL 2073 EVNNL 3073 EVNNL 9073 100 1/2" EVNNL 1105 EVNNL 2105 EVNNL 3105 EVNNL 9105 3/4" EVNNL 1103 EVNNL 2103 EVNNL 3103 EVNNL 9103 150 1/2" EVNNL 1155 EVNNL 2155 EVNNL 3155 EVNNL 9155 3/4" EVNNL 1153 EVNNL 2153 EVNNL 3153 EVNNL 9153 200 1/2" EVNNL 1205 EVNNL 2205 EVNNL 3205 EVNNL 9205 3/4" EVNNL 1203 EVNNL 2203 EVNNL 3203 EVNNL 9203 250 1/2" EVNNL 1255 EVNNL 2255 EVNNL 3255 EVNNL 9255 3/4" EVNNL 1253 EVNNL 2253 EVNNL 3253 EVNNL 9253 Metal Halide 100 1/2" EVNHL 1105 EVNHL 2105 EVNHL 3105 EVNHL 9105 Ex dnR IIC T4 IP66 Ex nR II T3 IP66 Ex DP II 11 IP66 3/4" EVNHL 1103 EVNHL 2103 EVNHL 3103 EVNHL 9103 175 1/2" EVNHL 1175 EVNHL 2175 EVNHL 3175 EVNHL 9175 3/4" EVNHL 1173 EVNHL 2173 EVNHL 3173 EVNHL 9173 250 1/2" EVNHL 1255 EVNHL 2255 EVNHL 3255 EVNHL 9255 Ex dnR IIC T3 IP66 Ex nR II T3 IP663/4" EVNHL 1253 EVNHL 2253 EVNHL 3253 EVNHL 9253 Ordering Information Dimension E V N N L 1 0 5 5 - DR ① ② ③ ④ ⑤ ⑥ EVN Lighting Fixture① Lamp Type② NL - High Pressure Sodium Mounting Type③ HL - Metal Halide 1 - Pendant ML - Mercury Vapour 2 - Ceiling 3 - Bracket Lamp Wattage (W)④ 9 - Stanchion 05 - 50 07 - 70 Entry Size⑤ 10 - 100 1 - 1" 15 - 150 3 - 3/4" 17 - 175 5 - 1/2" 20 - 200 25 - 250 Options⑥ DR - Dome Reflector AR - Angle Reflector C※ an order Aluminium Reflector instead of FRP Reflector < Pendant Type > < Ceiling Type >
  • 50. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm <EVNNL 2255-DR> 0 81.0 50 135 5 81.0 55 138Lamp : NH250 (25000 lm)+ With Globe and without Guard+ Reflector : FRP Dome Reflector+ 10 81.0 60 145 15 87.8 65 148 20 97.9 70 148 25 111 75 148 30 115 80 125 35 115 85 81.0 40 122 90 33.8 45 128 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio/RCR 20% Effective Floor Cavity Reflectance 0 .92 .92 .92 .90 .90 .90 .86 .86 .86 .82 .82 .82 .79 .79 .79 .77 1 .79 .75 .72 .77 .73 .70 .74 .71 .68 .70 .68 .66 .68 .66 .64 .62 250 1 2 .67 .61 .56 .65 .60 .55 .62 .58 .54 .60 .56 .52 .57 .54 .51 .49 3 .57 .50 .44 .56 .49 .44 .54 .48 .43 .51 .46 .42 .49 .45 .42 .40 200 0.8 4 .50 .42 .36 .49 .42 .36 .47 .40 .36 .45 .39 .35 .43 .38 .34 .33 5 .44 .36 .30 .43 .36 .30 .41 .35 .30 .40 .34 .30 .38 .33 .29 .27 150 0.56 6 .39 .31 .26 .38 .31 .26 .37 .30 .26 .35 .30 .25 .34 .29 .25 .23 7 .35 .28 .23 .34 .27 .22 .33 .27 .22 .32 .26 .22 .31 .26 .22 .20 8 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .28 .23 .19 .18 9 .29 .22 .18 .29 .22 .18 .28 .22 .18 .27 .21 .17 .26 .21 .17 .16 10 .27 .20 .16 .26 .20 .16 .26 .20 .16 .25 .19 .16 .24 .19 .16 .14 Angle cd/1000 lm Angle cd/1000 lm <EVNHL 2175-DR> 0 91.6 50 149 5 91.6 55 143Lamp : MH175 (14000 lm)+ With Globe and without Guard+ Reflector : FRP Dome Reflector+ 10 97.4 60 143 15 97.4 65 143 20 115 70 143 25 126 75 137 30 132 80 132 35 137 85 91.6 40 137 90 17.2 45 143 Multipliers Coefficients of Utilization - Zonal Cavity (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 250 1.47 0 .96 .96 .96 .94 .94 .94 .90 .90 .90 .86 .86 .86 .82 .82 .82 .81 1 .82 .78 .75 .80 .77 .74 .77 .74 .71 .74 .71 .69 .71 .69 .67 .65 175 1 2 .70 .64 .59 .69 .63 .58 .66 .61 .57 .63 .59 .55 .60 .57 .54 .52 3 .60 .53 .47 .59 .52 .47 .57 .51 .46 .54 .49 .45 .52 .48 .44 .42 4 .53 .45 .39 .52 .44 .39 .50 .43 .38 .48 .42 .38 .46 .41 .37 .35 5 .47 .39 .33 .46 .38 .33 .44 .37 .32 .42 .36 .32 .41 .36 .32 .30 6 .42 .34 .28 .41 .34 .28 .39 .33 .28 .38 .32 .28 .37 .31 .27 .26 7 .38 .30 .25 .37 .30 .25 .36 .29 .24 .34 .29 .24 .33 .28 .24 .22 8 .34 .27 .22 .34 .27 .22 .33 .26 .22 .32 .26 .22 .31 .25 .21 .20 9 .31 .24 .20 .31 .24 .20 .30 .24 .19 .29 .23 .19 .28 .23 .19 .18 10 .29 .22 .18 .28 .22 .18 .28 .22 .18 .27 .21 .18 .26 .21 .17 .16
  • 51. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Compact Fluorescent Lighting Fixtures EVN Series Wet Locations NEMA 3,3R,4,4X,7,9 Type of Explosion-proof Technical Data Electrical Ratings Non Sparking (Ex nR II T4 IP66) Dust Ignition-proof (Ex DP II 11 IP66) Rated Voltage AC110V/ 220V/ 240V Rated Wattage 13W×3, 18W×3, 26W×3 < EVNCL 1263 > Rated Frequency 50Hz/ 60Hz Entry Sizes 1/2", 3/4", 1" Weight Mounting Type Catalog No. Weight Pendant EVNCL 1263 9 Kg Standard Materials Housing, mounting modules, component pallets : Fiber glass reinforced polyester resin Globe : Heat resistant hard glass Gasket : Silicone rubber Reflector : Fiber glass Reinforced Polyester External Hardware : Stainless steel, Brass Application Features Certification EVN Series lighting fixtures are used ; in manufacturing plants, refineries, chemical, petrochemical and other industrial process facilities, wastewater and sewage treatment plants, offshore, dockside and other harbor installations as well as other heavy industrial applications. wherever the damaging effects of water, wind, snow, sleet, hot sun or any combination of these elements are found. in withstands the harshest of corrosive environments. to provide low wattage spot and floodlighting. where an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, will persist for a short period only. where combustible dust, moisture, dirt are present and vibration, corrosion, rough usage are problems. Enclosure in glass fiber reinforced polyester resin, provide excellent resistant to corrosion so have a long life. Enclosure contain ultraviolet interception ingredient to resist transformation. Easy installation and maintenance Internal type ballast. Pendant mounting module equipped with integral hub set screws for vibration resistance. Guard, hub inserts, stanchion elbow and hardware made of stainless steel for maximum resistance to corrosion. Grounding wire for safety. Hinged assembly allows the fixture to hang free during installation to permit the use of both hands when wiring. Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Compliance IEC 60079-0, 15 NEMA 3, 3R, 4, 4X Standard Finish Dark Gray If you want another color, contact us please. Options With Dome Reflector or 30° Angle Reflector with SMC or High Grade Aluminium If you need more information, contact us please.⇨
  • 52. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Hub Size Pendant Ceiling Bracket Stanchion Certification Compact Fluorescent 13W×3 1/2" EVNCL 1135 EVNCL 2135 EVNCL 3135 EVNCL 9135 Ex nR II T4 Ex DP II 12 3/4" EVNCL 1133 EVNCL 2133 EVNCL 3133 EVNCL 9133 18W×3 1/2" EVNCL 1185 EVNCL 2185 EVNCL 3185 EVNCL 9185 3/4" EVNCL 1183 EVNCL 2183 EVNCL 3183 EVNCL 9183 26W×3 1/2" EVNCL 1265 EVNCL 2265 EVNCL 3265 EVNCL 9265 3/4" EVNCL 1263 EVNCL 2263 EVNCL 3263 EVNCL 9263 Ordering Information EVN Lighting Fixture① E V N C L 1 1 3 5 - DR Lamp Type② ① ② ③ ④ ⑤ ⑥ CL - Compact Fluorescent Mounting Type③ Lamp Wattage (W)④ Entry Size⑤ Options⑥ 1 - Pendant 13 - 13W×3 1 - 1" DR - Dome Reflector with SMC 2 - Ceiling 18 - 18W×3 3 - 3/4" AR - Angle Reflector with SMC 3 - Bracket 26 - 26W×3 5 - 1/2" C※ an order Aluminium Reflector instead of FRP Reflector9 - Stanchion ▞ Photometric Data Angle cd/1000 lm Angle cd/1000 lm <EVNCL 2265-DR> 0 86.0 50 111 5 86.0 55 111Lamp : CFL26+ ×3 (5400 lm) With Globe and without Guard+ Reflector : FRP Dome Reflector+ 10 86.0 60 109 15 87.5 65 106 20 90.6 70 96.9 25 93.7 75 82.9 30 98.4 80 64.1 35 103 85 43.7 40 106 90 25.0 45 109 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .67 .67 .67 .66 .66 .66 .63 .63 .63 .60 .60 .60 .58 .58 .58 .57 1 .58 .56 .53 .57 .55 .53 .55 .53 .51 .52 .51 .49 .50 .49 .48 .47 2 .50 .46 .43 .49 .45 .42 .47 .44 .41 .45 .43 .40 .44 .41 .39 .38 3 .44 .39 .35 .43 .38 .35 .41 .37 .34 .40 .36 .33 .38 .35 .33 .32 4 .38 .33 .29 .38 .33 .29 .36 .32 .29 .35 .31 .28 .34 .30 .28 .27 5 .34 .29 .25 .34 .28 .25 .32 .28 .24 .31 .27 .24 .30 .27 .24 .23 6 .31 .25 .22 .30 .25 .21 .29 .25 .21 .28 .24 .21 .27 .24 .21 .20 7 .28 .23 .19 .27 .22 .19 .26 .22 .19 .25 .21 .19 .25 .21 .18 .17 8 .25 .20 .17 .25 .20 .17 .24 .20 .17 .23 .19 .17 .23 .19 .16 .15 9 .23 .18 .15 .23 .18 .15 .22 .18 .15 .21 .18 .15 .21 .17 .15 .14 10 .21 .17 .14 .21 .17 .14 .20 .16 .14 .20 .16 .14 .19 .16 .13 .12
  • 53. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Dimension < EVN Bracket Type > < EVN Stanchion Type > < EVN Pendant Type > < EVN Ceiling Type >
  • 54. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures EU Series Wet Locations Factory Sealed NEMA 3, 3R, 7 Type of Explosion-proof Flameproof (Ex d IIB T4) Dust Ignition-proof (Ex DP II 12) < EU > Application Features EU Series lighting fixtures are used; in tunnels, building entrances and similar locations where moisture, dirt, chemicals or rough usage are a problem. in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in areas where combustible dusts and flammable vapors are present simultaneously. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. where high light output is needed but space is limited. where ignitable concentrations of flammable gases, vapors, liquids or dusts can exist some of the time under normal operating conditions. Lighting unit and ballast are constructed separately so as to protect the ballast from the heat of the lamp. Lighting unit is screwed onto the top of the mounting box and the ballast to the side. Globe assembly is securely hinged to the body. Ballast is a high quality one maintaining much safety on strength of enclosure, weatherproof and temperature rise. Mounting box has four-way conduit entries and a large access cover for wiring. Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Standard Materials Certification Compliance Enclosure : Die casting aluminium Globe : Heat resistant hard glass Inner Reflector : High purity aluminium External Hardware : Stainless steel Mounting Box : Cast aluminium alloy Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Technical Data Weight Electrical Rating Mounting Type Catalog No. Weight Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Ceiling EUNL 32210 8.6 ㎏ Rated Wattage 50W/ 70W/ 100W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" Also you can order various voltage :※ 120V/ 208V/ 277V/ 460V If you need more information, contact us please.⇨
  • 55. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Volts Pendant Ceiling 90° Bracket 40° Bracket Certification High Pressure Sodium 50 100-120 EUNL 31105 EUNL 32105 EUNL 33105 EUNL 34105 Ex d IIB T3 200-220 EUNL 31205 EUNL 32205 EUNL 33205 EUNL 34205 70 100-120 EUNL 31107 EUNL 32107 EUNL 33107 EUNL 34107 200-220 EUNL 31207 EUNL 32207 EUNL 33207 EUNL 34207 100 100-120 EUNL 31110 EUNL 32110 EUNL 33110 EUNL 34110 200-220 EUNL 31210 EUNL 32210 EUNL 33210 EUNL 34210 Metal Halide 100 100-120 EUHL 31110 EUHL 32110 EUHL 33110 EUHL 34110 Ex d IIB T4 200-220 EUHL 31210 EUHL 32210 EUHL 33210 EUHL 34210 Mercury Vapor 100 100-120 EUML 31110 EUML 32110 EUML 33110 EUML 34110 200-220 EUML 31210 EUML 32210 EUML 33210 EUML 34210 * For Pole type, see pole section (2L-51) Ordering Information Temperature Performance Data E U N L 3 2 1 1 0 Lamp Ambient Flameproof Dust-Ignition ① ② ③ ④ ⑤ ⑥ Type Watt. Temp ( )℃ "d" "DP" EU Lighting Fixture① Mounting Type④ H.I.D 50 40 T4 12 1 - Pendant 55 - - Lamp Type② 2 - Ceiling 70 40 T4 12 NL - H.P.Sodium 3 - 90° Bracket 55 - - HL - Metal Halide 4 - 40° Bracket 100 40 T4 12 ML - Mercury Vapor 55 - - Voltage (V)⑤ Type of Lighting Fixture③ 1 - 100-120 3 - EUL Type 2 - 200-220 Wattage (W)⑥ 05 - 50, 07 - 70, 10 - 100 Dimension <Ceiling Type> <Pendant Type> <90° Bracket Type > <40° Bracket Type >
  • 56. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle /1000㏅ ㏐ Angle /1000㏅ ㏐ <EUNL 32110> 0 93.7 50 107 5 76.8 55 112Lamp : NH100 (9000 lm)+ With Guard+ 10 77.8 60 116 15 81.5 65 125 20 76.8 70 131 25 77.8 75 132 30 81.5 80 133 35 87.2 85 139 40 91.9 90 143 45 99.4 Coefficients of Utilization - Zonal Cavity Multipliers %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 (For use with candlepower curves only) %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .85 .85 .85 .83 .83 .83 .79 .79 .79 .76 .76 .76 .73 .73 .73 .71 1 .71 .67 .63 .69 .66 .62 .66 .63 .60 .63 .61 .59 .61 .59 .57 .55 100 1 2 .59 .53 .48 .58 .52 .47 .55 .50 .46 .52 .48 .45 .50 .47 .44 .42 3 .50 .43 .37 .49 .42 .37 .46 .41 .36 .44 .39 .35 .42 .38 .34 .33 70 0.5 4 .43 .36 .30 .42 .35 .30 .40 .34 .29 .38 .33 .29 .37 .32 .28 .26 5 .38 .30 .25 .37 .30 .25 .35 .29 .24 .34 .28 .24 .32 .27 .24 .22 50 0.25 6 .34 .26 .21 .33 .26 .21 .31 .25 .21 .30 .25 .20 .29 .24 .20 .19 7 .30 .23 .18 .30 .23 .18 .28 .22 .18 .27 .22 .18 .26 .21 .18 .16 8 .27 .21 .16 .27 .20 .16 .26 .20 .16 .25 .20 .16 .24 .19 .16 .14 9 .25 .19 .14 .25 .18 .14 .24 .18 .14 .23 .18 .14 .22 .17 .14 .12 10 .23 .17 .13 .23 .17 .13 .22 .16 .13 .21 .16 .13 .21 .16 .13 .11 Angle /1000㏅ ㏐ Angle /1000㏅ ㏐ <EUHL 32110> 0 123 50 98.7 5 112 55 104Lamp : MH100 (6500 lm)+ With Guard+ 10 114 60 109 15 117 65 149 20 116 70 147 25 135 75 148 30 140 80 144 35 121 85 134 40 101 90 106 45 97.3 Coefficients of Utilization - Zonal Cavity %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .95 .95 .95 .93 .93 .93 .89 .89 .89 .85 .85 .85 .82 .82 .82 .80 1 .80 .76 .72 .78 .74 .71 .75 .72 .69 .72 .69 .67 .69 .67 .65 .63 2 .67 .61 .55 .66 .60 .54 .63 .58 .53 .60 .56 .52 .57 .54 .51 .49 3 .57 .50 .44 .56 .49 .43 .54 .47 .42 .51 .46 .41 .49 .45 .41 .39 4 .50 .42 .36 .49 .41 .35 .47 .40 .35 .45 .39 .34 .43 .38 .34 .32 5 .44 .36 .30 .43 .36 .30 .41 .35 .29 .40 .34 .29 .38 .33 .29 .27 6 .40 .32 .26 .39 .31 .26 .37 .30 .25 .36 .30 .25 .34 .29 .25 .23 7 .36 .28 .23 .35 .28 .23 .34 .27 .22 .33 .27 .22 .31 .26 .22 .20 8 .33 .25 .20 .32 .25 .20 .31 .25 .20 .30 .24 .20 .29 .24 .20 .18 9 .30 .23 .18 .30 .23 .18 .29 .22 .18 .28 .22 .18 .27 .22 .18 .16 10 .28 .21 .17 .27 .21 .17 .27 .21 .17 .26 .20 .16 .25 .20 .16 .15
  • 57. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 H.I.D Lighting Fixtures EA Series Wet Locations Factory Sealed NEMA 3, 3R, 7 < EA > Type of Explosion-proof Flameproof (Ex d IIB T4 H2) Flameproof (Ex d IIC T4 H2) Standard Materials Enclosure : Die casting aluminium alloy Globe : Heat resistant hard glass Inner Reflector : High purity aluminium Guard : Stainless steel Standard Finish MUNSELL No. 7.5BG 6/1.5 If you want another color, contact us please. Application Features Globe assembly is securely hinged to the body. Easy installation and maintenance. Hinged assembly allows the fixture to hang free during installation to permit the use of both hands when wiring. Can use compact fluorescent lamp 45W instead of HID lamp without external ballast. EA Series lighting fixture are used ; in heavy process industries having environments where flammable or explosive vapors or gases, or where combustible dusts are present. in paint spray booth suitability provides efficient, economical HID lighting for paint spray areas. in hazardous areas, both indoors and outdoors where long life and low maintenance costs are desired. in hazardous locations requiring elevated ambient capability. in marine applications where water spray and corrosive atmospheres are considerations. Lighting unit and ballast are constructed separately so as to protect the ballast from the heat of the lamp. Base of the body and the top of the globe holder have accurate tapered cylindrical surfaces and are secured by four socket head captive screw. Lighting unit is screwed onto the top of the mounting box and the ballast to the side. Pendant mounting module equipped with integral hub set screws for vibration resistance. Globe assembly is securely hinged to the body. Compliance & Certification IEC 60079-0, 1 NEMA 3, 3R, 7 IP 55 Certified by KOSHA (Korea Occupational Safety & Health Agency), KGS (Korea Gas Safety Corporation), and the others. Technical Data Lamp Replacement Electrical Rating Rated Voltage AC110V/ 220V/ 240V ( See Below)※ Rated Wattage 100W/ 150W/ 175W/ 200W/ 250W/ 400W Rated Frequency 50Hz/ 60Hz Entry Size 1/2", 3/4", 1" Also you can order various voltage :※ 110V/ 120V/ 208V/ 220V/ 240V/ 277V/ 460V Weight Mounting Type Catalog No. Weight Small (Ceiling) EANL 2215 17.3 ㎏ Large (Ceiling) EAML 2240 28.3 ㎏ If you need more information, contact us please.☞
  • 58. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Ordering Number Lamp Watt Pendant Ceiling 90° Bracket 40° Bracket Certification High Pressure Sodium 150 EANL 2115 EANL 2215 EANL 2315 EANL 2415 Ex d IIC T4200 EANL 2120 EANL 2220 EANL 2320 EANL 2420 250 EANL 2125 EANL 2225 EANL 2325 EANL 2425 400 EANL 2140 EANL 2240 EANL 2340 EANL 2440 Ex d IIB T3 Metal Halide 175 EAHL 2117 EAHL 2217 EAHL 2317 EAHL 2417 Ex d IIC T4 250 EAHL 2125 EAHL 2225 EAHL 2325 EAHL 2425 400 EAHL 2140 EAHL 2240 EAHL 2340 EAHL 2440 Ex d IIB T3 Mercury Vapor 200 EAML 2120 EAML 2220 EAML 2320 EAML 2420 Ex d IIC T4 250 EAML 2125 EAML 2225 EAML 2325 EAML 2425 400 EAML 2140 EAML 2240 EAML 2340 EAML 2440 Ex d IIB T3 Dimension Ordering Information <Ceiling Type> <Pendant Type> <40°Bracket Type> <90°Bracket Type> E A N L 2 1 1 5 ① ② ③ ④ ⑤ EA Lighting Fixture① Mounting Type④ 1 - Pendant 2 - Ceiling Lamp Type② 3 - 90° Bracket NL - High Pressure Sodium 4 - 40° Bracket HL - Metal Halide ML - Mercury Vapour ⑤ Lamp Wattage(w) 15 - 150 17 - 175 Model Type③ 20 - 200 2 - EA Type 25 - 250 40 - 400 Temperature Performance Data Lamp Ambient Flame Type Watt. Temp ( )℃ Proof "d" High Pressure Sodium 150 40 T4 55 T4 200 40 T4 55 T4 250 40 T4 55 T4 400 40 T3 55 T3 Metal Halide 175 40 T4 55 T4 250 40 T4 55 T4 400 40 T3 55 T3 Mercury Vapor 200 40 T4 55 T4 250 40 T4 55 T4 400 40 T3 55 T3
  • 59. Lighting Fixture Copyright by NAMBUK Electric Co., LTD. 2004 Photometric Data Angle cd/1000 lm Angle cd/1000 lm 0 122 50 161<EAHL 2225> 5 108 55 171 Lamp : MH250 (20500 lm)+ With Globe and without Guard+ 10 94.4 60 164 15 105 65 126 20 143 70 115 25 170 75 112 30 147 80 80.4 35 133 85 38.4 40 129 90 17.4 45 133 Coefficients of Utilization - Zonal Cavity Multipliers (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74 1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62 250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52 3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43 175 0.68 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36 5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31 6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27 7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24 8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21 9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19 10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17 Angle cd/1000 lm Angle cd/1000 lm 0 172 50 118<EANL 2225> 5 135 55 125 Lamp : NH250 (25000 lm)+ With Globe and without Guard+ 10 94.5 60 125 15 105 65 125 20 142 70 108 25 182 75 87.8 30 142 80 67.5 35 108 85 50.6 40 97.9 90 30.4 45 101 Coefficients of Utilization - Zonal Cavity Multipliers (For use with candlepower curves only) %Effective Ceiling Cavity Reflectance( cc)ρ 80 70 50 30 10 0 %Wall Reflectance(ρw) 50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0 Lamp Watts Conversion Factor Room Cavity Ratio RCR 20% Effective Floor Cavity Reflectance 0 .89 .89 .89 .87 .87 .87 .83 .83 .83 .79 .79 .79 .76 .76 .76 .74 1 .77 .74 .71 .76 .73 .70 .72 .70 .68 .70 .68 .66 .67 .65 .64 .62 250 1 2 .67 .62 .58 .66 .61 .57 .63 .59 .56 .61 .57 .54 .58 .56 .53 .52 3 .59 .53 .48 .58 .52 .47 .55 .50 .46 .53 .49 .46 .51 .48 .45 .43 200 0.8 4 .52 .45 .40 .51 .45 .40 .49 .44 .39 .47 .42 .39 .46 .41 .38 .36 5 .46 .39 .34 .45 .39 .34 .44 .38 .34 .42 .37 .33 .41 .36 .33 .31 150 0.56 6 .41 .35 .30 .41 .34 .30 .39 .34 .29 .38 .33 .29 .37 .32 .29 .27 7 .38 .31 .26 .37 .31 .26 .36 .30 .26 .35 .30 .26 .34 .29 .26 .24 8 .34 .28 .23 .34 .28 .23 .33 .27 .23 .32 .27 .23 .31 .26 .23 .21 9 .31 .25 .21 .31 .25 .21 .30 .25 .21 .29 .24 .21 .29 .24 .21 .19 10 .29 .23 .19 .29 .23 .19 .28 .23 .19 .27 .22 .19 .27 .22 .19 .17