SlideShare una empresa de Scribd logo
1 de 16
Descargar para leer sin conexión
Helsinki University of Technology Department of Mechanical Engineering
Energy Engineering and Environmental Protection Publications
Steam Boiler Technology eBook
Espoo 2002
Boiler Calculations
Sebastian Teir, Antto Kulla
Helsinki University of Technology
Department of Mechanical Engineering
Energy Engineering and Environmental Protection
ii
Table of contents
Steam/water diagrams used in boiler calculations ...............................................................................1
Temperature-heat (T-Q) diagram.....................................................................................................1
Temperature-entropy (T-s) diagram.................................................................................................2
Pressure-enthalpy (p-h) diagram......................................................................................................3
Enthalpy-entropy (Mollier, h-s) diagram.........................................................................................4
Determination of steam/water parameters ...........................................................................................5
Given parameters .............................................................................................................................5
Pressure losses..................................................................................................................................5
Procedure for determination of specific enthalpies and mass flow rates.........................................6
Superheaters and reheaters...............................................................................................................7
Spray water group mass flow...........................................................................................................7
Calculations of heat load..................................................................................................................8
Evaporator....................................................................................................................................8
Superheater...................................................................................................................................9
Reheater .......................................................................................................................................9
Economizer ..................................................................................................................................9
Air preheater ................................................................................................................................9
Determination of boiler efficiency.....................................................................................................10
Standards........................................................................................................................................10
Major heat losses............................................................................................................................10
Heat loss with unburned combustible gases ..............................................................................10
Heat loss due to unburned solid fuel..........................................................................................10
Heat loss due to wasted heat in flue gases .................................................................................11
Heat loss due to wasted heat in ashes ........................................................................................11
Losses due to heat transfer (radiation) to the environment........................................................12
Losses of blowdown, sootblowing and atomizing steam...........................................................12
Internal power consumption...........................................................................................................12
Calculating boiler efficiency..........................................................................................................12
Direct method.............................................................................................................................13
Indirect method ..........................................................................................................................13
References..........................................................................................................................................14
1
Steam/water diagrams used in boiler calculations
Temperature-heat (T-Q) diagram
The T-Q diagram is a useful tool for designing heat exchangers. It can also be used to present the
heat transfer characteristics of an existing heat exchanger or heat exchanger network. The T-Q
diagram consists of two axes: The current stream temperature on the y-axis and the amount of
heat transferred on the x-axis. Sometimes the streams are marked with arrowheads to clarify the
direction of the streams, but these are not necessary: since heat cannot move from the colder
stream to the hotter stream according to the second law of thermodynamics, the directions of the
streams are explicitly determined: The hot stream transfers its heat to the cold stream, thus the
flow direction of the hot stream is towards lower temperature and the flow direction of the cold
stream is towards higher temperatures. For the same reason, the hot stream is always above the
cold stream in the T-Q diagram (figure 1).
Figure 1: Examples of T-Q diagrams for a parallel flow heat exchanger (left), and a counter (or
cross) flow heat exchanger (middle). The hot stream is marked with red color and the cold with
blue color.
When designing or
reviewing heat
exchanger networks, the
T-Q diagram gets useful.
The T-Q diagram is
therefore applied when
designing boilers;
especially the heat
exchanger surface
arrangement can be
clearly visualized with a
T-Q diagram (figure 2).
0
200
400
600
800
1000
1200
1400
1600
0 % 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % 100 %
Share of heat load [%]
Temperature[°C]
Flue gas stream
Water/steam stream
Air stream
Furnace
Superheater Economizer
Air preheater
Figure 2: Example of a T-Q diagram representing the heat surfaces
in a PCF boiler.
2
Temperature-entropy (T-s) diagram
The T-s diagram represents the
various phases of steam/water with
temperature as a function of the
specific entropy. It is often used to
visualize steam power processes. The
T-s diagram is also commonly used
for displaying reversible processes
(or real processes simplified as
reversible processes), which in the T-
s diagram appear as closed curves
(loop).
The left border, up to the critical
point, is the border where the liquid
is saturated (figure 3). That is, the
water is still liquid and contains no
steam. But if we go further right
(increase the entropy), steam bubbles
starts to form in the water. In other
words, saturated water starts to boil
when heat is added and entropy is
increased.
The enclosed region in the middle is
the region where water is a mixture
of vapor and liquid. Steam that
contains water in any form, either as
minute droplets, mist or fog, is called
wet steam. The quantity called ‘x’ in
the diagram
Critical point
p=constant
p=constant
p = constant
p = constant
v=constant
v = constant
Liquid-vapour region
Saturated
vapour
Saturatedliquid
X = 0,2 X = 0,9
Temperature
Entropy
Figure 3: Simplified T-s diagram of steam/water.
represents the amount (percentage by weight) of dry vapor in the wet steam mixture. This
quantity is called the quality of steam. For instance, if there is 10 % moisture in the steam, the
quality of the steam is 90 % or 0,9. The temperature of wet steam is the same as dry saturated
steam at the same pressure.
The right border, down from the critical point, is the line where steam is saturated. When steam
is heated beyond that border, steam is called superheated.
Water boils under constant temperature and pressure, so a horizontal line inside the enclosed
region represents a vaporization process in the T-s diagram. The steam/water heating process in
the boiler represented by the diagram in figure 2 can also be drawn in a T-s diagram (figure 4), if
the boiler pressure is assumed to be e.g. 10 MPa.
3
Figure 4: Detailed T-s diagram of the PCF boiler steam/water heating process from figure 2
(note: color of the steam/water process line is changed from blue to red).
Pressure-enthalpy (p-h) diagram
Another tool used in boiler
calculation is the pressure-
enthalpy diagram for
steam/water (figure 5).
With the p-h diagram it is
easy to visualize the partial
shares of the total heat load
on different heat exchanger
surfaces in the boiler:
drawing the steam heating
process in the boiler onto
the p-h diagram will give a
horizontal line (if we
simplify the process and
set pressure losses to zero).
Figure 6 shows the same
boiler steam/water process
from figure 4, drawn in the
steam/water p-h diagram.
60 °C
100 °C
200 °C
300 °C
400 °C 500 °C 600 °C
0 500 1000 1500 2000 2500 3000 3500 4000
10 kPa
100 kPa
1 MPa
10 Mpa
20 MPa
50 MPa
Enthalpy [kJ/kg]
Pressure
Critical point
Saturatedvapor
Saturatedliquid
Figure 5: Simplified p-h diagram for steam/water.
4
Figure 6: Detailed p-h diagram of the PCF boiler steam/water heating process (red line) from
figure 4.
Enthalpy-entropy (Mollier, h-s) diagram
The most frequently used tool for determining
steam properties is probably the enthalpy-
entropy (h-s) diagram, also called Mollier
diagram (figure 7). If two properties of the
steam state are known (like pressure and
temperature), the rest of the properties for
steam (enthalpy, entropy, specific volume and
moisture content) can be read from the
diagram. A more detailed h-s diagram can be
found in figure 8. Since the diagram is very
large, the diagram is usually found as two
versions, consisting of zoomed portions of the
original: one for steam properties (figure 7)
and another for water properties.
Critical point
p=constant
p=constant
T = constant
T = constant
Liquid-vapour region
X = 0,96
X = 0,90
Saturatedvapour
Figure 7: Mollier (h-s) diagram, simplified
version.
5
Figure 8: Large-scale Mollier h-s diagram for steam.
Determination of steam/water parameters
Given parameters
Normally in a steam boiler design assignment the parameters describing the live (output) steam,
e.g. mass flow, pressure and temperature are given. If the steam boiler to be designed has a
reheat cycle, also reheat pressure and temperature are given. Reheat steam mass flow can be
given as well. These parameters are used to determine the rest of the steam/water parameters.
Pressure losses
The pressure losses in the heat exchanger units of the boiler are estimated according to the
following approximations:
• Economizer: the pressure loss is 5-10 % of the pressure of the feedwater entering the
economizer.
• Evaporator:
Once through boilers: in once-through boilers the pressure loss of the evaporator is
between 5 and 30 %.
Forced and natural circulation boilers: the pressure drop in the evaporator part of drum-
based boilers does not affect the pressure loss of the main steam/water flow through the
boiler. This means that saturated steam leaving the steam drum has the same pressure as
the feedwater entering the steam drum. The pressure loss of the evaporator has to be
overcome using the driving force (natural circulation) or circulation pump (forced
circulation).
6
• Superheater: the total pressure drop of all superheater packages is less than 10 % of the
pressure of the superheated steam.
• Reheater: the pressure drop in the reheater is about 5 % of the pressure of reheated steam
Pressure losses of connection tubes between different heat transfer surfaces (e.g. between
evaporator and superheater) can be neglected in these calculations.
Procedure for determination of specific enthalpies and mass flow
rates
1. The specific enthalpy of the superheated steam can be determined with an h-s diagram if both
the temperature and the pressure of the steam are known. Thus, the specific enthalpies for
live (superheated) steam and reheated steam can be calculated.
2. The total pressure loss of the superheater stages should be chosen. Thus, the pressure in
steam drum (drum-type boilers) or pressure after evaporator (once-through boilers) can be
calculated by adding the pressure loss over the superheater stages to the pressure of the
superheated steam.
3. Specific enthalpy of saturated water and steam (in the steam drum) can be read from an h-s
diagram or steam tables, as the pressure in the steam drum is known.
In once-through boilers the determination of specific enthalpy after the evaporator is based
on the temperature. The reason for this is the unclear state of supercritical steam after the
evaporator in once-through circulation. The temperature after the evaporator in once-through
boilers is typically between 400 and 450 °C.
4. For removal of minerals concentrated in the steam drum, a part of the water in steam drum is
removed as blowdown water from the bottom of the steam drum. Normally the mass flow
rate of blowdown is 1-3 % of the mass flow rate of feedwater coming into steam drum.
5. In principle, the feedwater coming into steam drum should be saturated water. To prevent the
feedwater from boiling in the transportation pipes, the temperature of the feedwater reaching
the steam drum is 15-30 °C below saturation temperature. The feedwater is then called
subcooled (in contrast to supercooled). When the temperature in the steam drum and the
value of subcooling are known, the temperature after the economizer can be determined. The
water pressure after the economizer can be assumed to be equal to the pressure in the steam
drum and specific enthalpy after the economizer can then be read from a h-s diagram.
In once through boilers the pressure after the economizer can be calculated by adding the
pressure loss in the evaporator to the pressure after evaporator. The temperature after the
evaporator is normally between 300 and 350 °C (can be chosen). Knowing the pressure and
the temperature, the specific enthalpy after the evaporator can be defined.
6. The pressure before the economizer can be calculated by adding the pressure loss in the
economizer to the feedwater pressure after economizer. The feedwater temperature might be
stated in the boiler design assignment. If it is not given, it should be chosen from the range of
200-250 °C. The mass flow rate before the economizer is the blowdown mass flow rate
added to the mass flow rate from the steam drum to the superheaters.
7
Superheaters and reheaters
Reheating takes usually place in two stages.
The pressure before the reheater is the reheated
steam pressure added on the pressure loss in
the reheater. The steam goes through a high-
pressure turbine before it enters the reheater. In
the high-pressure turbine, the specific enthalpy
of steam decreases according to the isentropic
efficiency of the turbine. Isentropic efficiency
is normally between 0,8 and 0,9. A part of the
low-pressure steam coming from high-pressure
turbine continues to the high-pressure
feedwater heater (closed-type feedwater
heater). However, the mass flow rate of
reheated steam is still 85-90 % of that of the
live steam.
Superheating is often applied in three stages
having spray water groups between each other
to reduce steam temperature when necessary.
Between reheaters, the steam temperature is
controlled using other means. Spray water
group dimensioning is usually based on a
I II III
354
410
435
475
505
535
t °C
Heat load
Figure 9: An example of the heat load share of
superheater stages.
steam temperature decrease of 15-40 °C by water spraying. Spray water originates normally from
the feedwater line before the economizer. Thus the pressure difference is the pressure loss of the
heat transfer surfaces between the economizer inlet and the location of the spray water nozzle.
An example of a possible heat load share between the superheater stages is shown in figure 9.
Pressure loss in superheaters can be divided into equal partial pressure losses corresponding to
each superheater stage. Pressure loss of the spray nozzles can be neglected. Temperature rise
over all superheaters can be divided into quite similar parts along the same principle.
Spray water group mass flow
Normally the mass flow rate of superheated steam (live steam) is known. Thus, mass flow rate
calculations start usually by calculating the mass flow rate of spray water to the last spray water
group (which is in this example between the second and third superheater stages). The mass flow
rates can be solved with energy and mass balance equations. With the equations below (equation
1), the mass flow rate of steam after second superheater stage and mass flow rate of spray water
to the last spray water group can be calculated. The mass flow rate of spray water to the first
spray water group can be calculated along the same procedure:
1,2, SHIIISHIIISPRAYSPRAYIISHIISHII
SHIIISPRAYIISHII
hmhmhm
mmm
⋅=⋅+⋅
=+
&&&
&&&
(1)
where SHIIm& is the mass flow rate of steam after second superheater stage [kg/s], SPRAYIIm& the
mass flow rate of spray water to second spray water group, SHIIIm& the mass flow rate of
superheated steam (live steam), 2,SHIIh the specific enthalpy of steam after second superheater
8
stage [kJ/kg], SPRAYh the specific enthalpy of spray water (feedwater), and 1,SHIIIh the specific
enthalpy of steam before third superheater stage. Figure 10 shows a flow chart with the symbols
visualized of the boiler arrangement used in this calculation model.
Reheat
IN
Air
IN
Coal
IN
HP Steam
OUT
Flue Gas
OUT
Ash
OUT
Feedwater
IN
HP Steam
OUT
SHIII RHSHI SHII
SPRAYII SPRAYI
EVAP
ECO
12 1212 12
1
2
APH
1
2
Figure 10: Flow chart of the PCF boiler arrangement used in this heat load calculation model.
Calculations of heat load
When the steam parameters and mass flows have been determined, the heat load of the heat
exchanger units can be calculated. The heat load is the heat transferred by a heat exchanger
(calculated in kW).
Evaporator
The heat load of the evaporator part of the boiler can be calculated as:
( ) ( )22 ECOBDECOSHEVAP hhmhhm −′+−′′= &&φ (2)
where SHm& is the mass flow of steam before superheater [kg/s], h ′′ the specific enthalpy of
saturated steam at steam drum pressure [kJ/kg], 2ECOh the specific enthalpy after economizer
BDm& the mass flow of blowdown water from steam drum, and h′ the specific enthalpy of
saturated water at steam drum pressure [kg/s].
9
Superheater
Normally superheating takes place in three or four stages in a big boiler. This calculation
example is based on three stage superheating. The heat load of the first superheater stage is
( )hhm SHISHSHI
′′−= 2,
&φ (3)
where 2,SHIh is the specific enthalpy of steam after the first superheater stage. In the second
superheater stage the heat load added can be calculated as:
( )1,2, SHIISHIISHIISHII hhm −= &φ (4)
where SHIIm& is the mass flow of steam before the second superheater [kg/s], 2,SHIIh the specific
enthalpy of steam after the second superheater stage [kJ/kg], and 1,SHIIh the specific enthalpy of
steam before the second superheater stage. Similarly, the heat load added in third superheater
stage can be calculated as:
( )1,2, SHIIISHIIISHIIISHIII hhm −= &φ (5)
wher SHIIIm& = Mass flow of steam before third superheater [kg/s], 2,SHIIIh the specific enthalpy of
steam after third superheater stage [kJ/kg], and 1,SHIIIh the specific enthalpy of steam before third
superheater stage [kJ/kg].
Reheater
The heat load of the reheater stage can be calculated as:
( )12 RHRHRHRH hhm −= &φ (6)
where RHm& is the mass flow rate of steam in the reheater [kg/s], 2RHh the specific enthalpy of
steam after the reheater [kJ/kg] , and 1RHh the specific enthalpy of steam before the reheater.
Economizer
The heat load of the economizer can be calculated as:
( )12 ECOECOECOECO hhm −= &φ (7)
where ECOm& is the mass flow rate of feedwater in the economizer [kg/s], 2ECOh the specific
enthalpy of feedwater after the economizer [kJ/kg], and 1ECOh the specific enthalpy of feedwater
before the economizer.
Air preheater
In order to calculate the heat load for the air preheater, we need to know the combustion air mass
flow, the temperature of the flue gases and the incoming air. The combustion air fed into air
preheater, is taken from upper part of the boiler room. The temperature of the combustion air
before the air preheater is therefore between 25 and 40°C (in Finnish conditions). The flue gases
10
exiting the boiler are usually kept above 130-150 °C in order to prevent corrosion. The enthalpies
can be taken from tables:
( )12 APHAPH
FUEL
AIR
FUELAPH hh
m
m
m −⋅⋅=
&
&
&φ (8)
where FUELm& is the mass flow rate of fuel fed into the boiler [kg/s],
FUEL
AIR
m
m
&
&
the mass flow rate of
combustion air divided by the mass flow rate of fuel fed into the boiler, 1APHh the specific
enthalpy of combustion air before the air preheater [kJ/kg], and 2APHh the specific enthalpy of
combustion air after the air preheater.
Determination of boiler efficiency
Standards
There are two main standards used for definition of boiler efficiency. Of those, the German DIN
1942 standard employs the lower heating value (LHV) of a fuel and is widely used in Europe.
The American ASME standard is based on higher heating value (HHV). However, this chapter
calculates the efficiency according to the DIN 1942 standard. [1]
It should be marked that with the DIN standard it is possible to reach boiler efficiencies over 100
%, if the condensation heat of the flue gases is recovered.
Major heat losses
Heat loss with unburned combustible gases
The typical unburned combustible gases are carbon monoxide (CO) and hydrogen (H2). In large
boilers usually only carbon monoxide can be found in significant amounts in flue gases.
Assuming that flue gases contain only these two gases, the losses [kW]can be calculated as:
22 ,,1 HlHCOlCOL HmHm ⋅+⋅= &&φ (9)
where COm& is the mass flow of carbon monoxide [kg/s], 2Hm& the mass flow of hydrogen,
COlH , the lower heating value (LHV) of carbon monoxide (10,12 MJ/kg), and 2,HlH the lower
heating value (LHV) of hydrogen (119,5 MJ/kg). If a relevant amount of some other flue gas
compound can be found in the flue gases, it should be added to the equation.
Heat loss due to unburned solid fuel
Unburned fuel can exit the furnace as well as bottom ash or fly ash. The heating value of ashes
can be measured in a specific laboratory test. The losses [kW] of unburned solid fuels can be
calculated as:
ubslubsL Hm ,2 ⋅= &φ (10)
11
where ubsm& is the total mass flow of unburned solid fuel (bottom ash and fly ash in total) [kg/s],
and ubslH , the lower heating value (LHV) of unburned solid fuel (fly ash and bottom ash in total)
[kJ/kg]. Some estimates of the losses with unburned solid fuels are presented in table 1:
Table 1: Estimates of losses with unburned solid fuel.
Boiler type Heat loss per heat input of fuel
Oil fired boiler 0,2 - 0,5 %
Coal fired boiler, dry ash removal 3 %
Coal fired boiler, molten ash removal about 2 %
Grate boiler 4-6 %
Heat loss due to wasted heat in flue gases
Flue gases leave the furnace in high temperature and thus they carry significant amount of
energy away from boiler process. To decrease flue gas losses, flue gas exit temperature should be
decreased. However, the acid dew point of flue gases restricts the flue gas temperature to about
130-150 °C for sulphur containing fuels. The losses caused by the sensible heat of flue gases can
be calculated as:
∑ ⋅⋅=
i
i
fuel
i
fuelL h
m
m
m
&
&
&3φ (11)
where fuelm& is the fuel mass flow [kg/s], im& the mass flow of a flue gas component, and ih the
specific enthalpy of a flue gas component (e.g. CO2) [kJ/kg].
Heat loss due to wasted heat in ashes
Ash can exit the furnace either as bottom ash from bottom of the furnace or as fly ash with flue
gases. The losses related to the sensible heat of ash can be calculated as:
fafapfababapbaL TcmTcm ∆⋅⋅+∆⋅⋅= ,,4
&&φ (12)
where bam& is the mass flow of the bottom ash [kg/s], bapc , the specific heat of the bottom ash
[kJ/(kgK)], baT∆ the temperature difference between the bottom ash temperature and the
reference temperature [°C], fam& the mass flow of fly ash, fapc , the specific heat of fly ash, faT∆
the temperature difference between the fly ash temperature and the reference temperature [°C].
Usually the reference temperature is 25 °C.
In recovery boilers the bottom ash is removed as molten ash in temperature of about 700-800 °C.
In addition, the amount of bottom ash divided by the amount of fuel is about 40 %. The loss of
sensible heat of ash is therefore of great importance in recovery boilers.
12
Losses due to heat transfer (radiation) to the environment
The main form of heat transfer from boiler to boiler room is radiation. It is proportional to the
outer surface area of the boiler and is usually 200-300 W/(m2K) for a well-insulated boiler
having its outer surface temperature below 55 °C. Another possibility to determine the heat
transfer losses to the environment is to use a table from the DIN 1942 standard, presented in
table 2.
Table 2: Estimations of heat transfer losses by radiation. [1]
Mass flow rate of steam [t/h]
Combustion method
10 20 40 60 80 100 200 400 600 800
Pulverized firing - 1,3 1,0 0,9 0,75 0,7 0,55 0,4 0,35 0,3
Grate 1,5 1,1 0,9 0,7 - - - - - -Loss [%]
Oil/gas fired boiler 1,3 0,9 0,7 0,6 0,55 0,4 0,3 0,25 0,2 0,2
Losses of blowdown, sootblowing and atomizing steam
Blowdown water from the steam drum and sootblowing steam (used to remove soot from heat
exchanger surfaces within the boiler) use a part of the steam produced by the boiler. This lowers
the boiler efficiency. In addition, steam is sometimes also used to atomize fuel in the burners.
The losses can be calculated as:
atomizingatomizingsbsbbdL hmhmhm ⋅+⋅+′⋅= &&&6φ (13)
bdm& is the mass flow of blowdown water [kg/s], h′ is the specific enthalpy of saturated water
(blowdown water from steam drum) [kJ/kg], sbm& is the mass flow of sootblowing steam, sbh is
the specific enthalpy of steam used for sootblowing (when leaving the boiler), atomizingm& is the
mass flow of atomizing steam, and atomizingh the specific enthalpy of steam used for atomizing the
fuel (when leaving the boiler) [kJ/kg].
Internal power consumption
The power plant itself consumes a part of the electricity produced. This is due to the various
auxilary equipments required, like feedwater pumps, circulation pumps and air/flue gas blowers.
In forced circulation boilers the share of electricity consumed by the circulation pump is about
0,5 % of the electricity produced by the plant.
Normally the internal power consumption is about 5 % of the electricity produced by the power
plant. Since the power used is electrical (and taken from the grid), the internal power
consumption share is reduced from the final boiler efficiency in boiler calculations.
Calculating boiler efficiency
There are two different means of calculating the boiler efficiency: The direct method and the
indirect method.
13
Direct method
In the direct method, the boiler efficiency is directly defined by the exploitable heat output from
the boiler and by the fuel power of the boiler:
input
output
φ
φ
η = (14)
where outputφ is the exploitable heat output from boiler, and inputφ the fuel power of the boiler.
Indirect method
Indirect method determines the efficiency of a boiler by the sum of the major losses and by the
fuel power of the boiler:
input
losses
φ
φ
η −=1 (15)
where lossesφ is the sum of the major losses within the boiler, and inputφ is the fuel power of the
boiler.
The indirect method provides a better understanding of the effect of individual losses on the
boiler efficiency.
14
References
1. DIN 1942. "Abnahmeversuche an Dampferzeugern".

Más contenido relacionado

La actualidad más candente

Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~iNtpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~ihaxxo24
 
Turbine cycle heat rate calculation
Turbine  cycle heat rate calculationTurbine  cycle heat rate calculation
Turbine cycle heat rate calculationSHIVAJI CHOUDHURY
 
Factors Affecting Boiler Performance
Factors Affecting Boiler PerformanceFactors Affecting Boiler Performance
Factors Affecting Boiler PerformanceManohar Tatwawadi
 
Ammonia plant material balance
Ammonia plant material balanceAmmonia plant material balance
Ammonia plant material balancePrem Baboo
 
Heat Exchanger recuperators
Heat Exchanger  recuperators  Heat Exchanger  recuperators
Heat Exchanger recuperators Ali Abdullah
 
Boiler efficiency by loss Method
Boiler efficiency by loss MethodBoiler efficiency by loss Method
Boiler efficiency by loss MethodRajeev Saini
 
Steam generating unit
Steam generating unitSteam generating unit
Steam generating unitJonalyn Cali
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlHossam Zein
 
Thermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam BoilerThermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam BoilerJohn Walter
 
Calculation of Turbine Efficiency
Calculation of Turbine EfficiencyCalculation of Turbine Efficiency
Calculation of Turbine EfficiencyJahanzeb Khan
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangersmohkab1
 
Cfb boiler basic design, operation and maintenance
Cfb boiler basic design, operation and maintenanceCfb boiler basic design, operation and maintenance
Cfb boiler basic design, operation and maintenancePichai Chaibamrung
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantIAEME Publication
 
Shell and tube heat exchanger design comparison
Shell and tube heat exchanger design comparisonShell and tube heat exchanger design comparison
Shell and tube heat exchanger design comparisonJuan Pablo Hernandez
 

La actualidad más candente (20)

Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~iNtpc (national thermal power corporation) sipat boiler haxxo24 i~i
Ntpc (national thermal power corporation) sipat boiler haxxo24 i~i
 
Turbine cycle heat rate calculation
Turbine  cycle heat rate calculationTurbine  cycle heat rate calculation
Turbine cycle heat rate calculation
 
Factors Affecting Boiler Performance
Factors Affecting Boiler PerformanceFactors Affecting Boiler Performance
Factors Affecting Boiler Performance
 
Boiler Presentation
Boiler PresentationBoiler Presentation
Boiler Presentation
 
Condensate system
Condensate systemCondensate system
Condensate system
 
Ammonia plant material balance
Ammonia plant material balanceAmmonia plant material balance
Ammonia plant material balance
 
Heat Exchanger recuperators
Heat Exchanger  recuperators  Heat Exchanger  recuperators
Heat Exchanger recuperators
 
Boiler efficiency by loss Method
Boiler efficiency by loss MethodBoiler efficiency by loss Method
Boiler efficiency by loss Method
 
Steam generating unit
Steam generating unitSteam generating unit
Steam generating unit
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Thermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam BoilerThermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam Boiler
 
Calculation of Turbine Efficiency
Calculation of Turbine EfficiencyCalculation of Turbine Efficiency
Calculation of Turbine Efficiency
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangers
 
Boilers
BoilersBoilers
Boilers
 
Heat Exchangers
Heat ExchangersHeat Exchangers
Heat Exchangers
 
Cfb boiler basic design, operation and maintenance
Cfb boiler basic design, operation and maintenanceCfb boiler basic design, operation and maintenance
Cfb boiler basic design, operation and maintenance
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Boiler Introduction
Boiler IntroductionBoiler Introduction
Boiler Introduction
 
Performance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plantPerformance evaluation and optimization of air preheater in thermal power plant
Performance evaluation and optimization of air preheater in thermal power plant
 
Shell and tube heat exchanger design comparison
Shell and tube heat exchanger design comparisonShell and tube heat exchanger design comparison
Shell and tube heat exchanger design comparison
 

Destacado

Spray & Maven Intro for Scala Barcelona Developers Meetup
Spray & Maven Intro for Scala Barcelona Developers MeetupSpray & Maven Intro for Scala Barcelona Developers Meetup
Spray & Maven Intro for Scala Barcelona Developers MeetupIgnasi Marimon-Clos i Sunyol
 
Portfolio Full compressed_2
Portfolio Full compressed_2Portfolio Full compressed_2
Portfolio Full compressed_2Sooraj Francis
 
Spray Democamp Dresden 2011-11-08
Spray Democamp Dresden 2011-11-08Spray Democamp Dresden 2011-11-08
Spray Democamp Dresden 2011-11-08joergreichert
 
Automated Historical Performance Analysis with kmemtracer
Automated Historical Performance Analysis with kmemtracerAutomated Historical Performance Analysis with kmemtracer
Automated Historical Performance Analysis with kmemtracerKyungmin Lee
 
Motivation through total reward rbs- haleem sadrey 2010
Motivation through total reward rbs- haleem sadrey 2010Motivation through total reward rbs- haleem sadrey 2010
Motivation through total reward rbs- haleem sadrey 2010guest9de12d
 
Pesticide Training Course UC Davis, Safety. Part 5 of 5
Pesticide Training Course UC Davis, Safety. Part 5 of 5Pesticide Training Course UC Davis, Safety. Part 5 of 5
Pesticide Training Course UC Davis, Safety. Part 5 of 5UC Davis
 
Ppt microencapsulation
Ppt microencapsulationPpt microencapsulation
Ppt microencapsulationSANA TABASSUM
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessoriesrudrik joshi
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its InternalsAshrant Dass
 
combustion equipment & power cycles
combustion equipment & power cyclescombustion equipment & power cycles
combustion equipment & power cyclesErasmus August
 
SPM Paper 2 Esei: FORCE AND PRESSURE
SPM Paper 2 Esei: FORCE AND PRESSURESPM Paper 2 Esei: FORCE AND PRESSURE
SPM Paper 2 Esei: FORCE AND PRESSURESuriyati Yusoff
 
Improving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemImproving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemKamlesh Hariyani
 
A Brief Introduction to Boilers
A Brief Introduction to BoilersA Brief Introduction to Boilers
A Brief Introduction to BoilersSATYAKAM MOHAPATRA
 

Destacado (20)

Spray & Maven Intro for Scala Barcelona Developers Meetup
Spray & Maven Intro for Scala Barcelona Developers MeetupSpray & Maven Intro for Scala Barcelona Developers Meetup
Spray & Maven Intro for Scala Barcelona Developers Meetup
 
Portfolio Full compressed_2
Portfolio Full compressed_2Portfolio Full compressed_2
Portfolio Full compressed_2
 
Spray Democamp Dresden 2011-11-08
Spray Democamp Dresden 2011-11-08Spray Democamp Dresden 2011-11-08
Spray Democamp Dresden 2011-11-08
 
Automated Historical Performance Analysis with kmemtracer
Automated Historical Performance Analysis with kmemtracerAutomated Historical Performance Analysis with kmemtracer
Automated Historical Performance Analysis with kmemtracer
 
Motivation through total reward rbs- haleem sadrey 2010
Motivation through total reward rbs- haleem sadrey 2010Motivation through total reward rbs- haleem sadrey 2010
Motivation through total reward rbs- haleem sadrey 2010
 
Lecture07
Lecture07Lecture07
Lecture07
 
Final Presentation
Final PresentationFinal Presentation
Final Presentation
 
Pesticide Training Course UC Davis, Safety. Part 5 of 5
Pesticide Training Course UC Davis, Safety. Part 5 of 5Pesticide Training Course UC Davis, Safety. Part 5 of 5
Pesticide Training Course UC Davis, Safety. Part 5 of 5
 
Ppt microencapsulation
Ppt microencapsulationPpt microencapsulation
Ppt microencapsulation
 
Steam boiler
Steam boilerSteam boiler
Steam boiler
 
Boiler accessories
Boiler accessoriesBoiler accessories
Boiler accessories
 
Tuna
Tuna Tuna
Tuna
 
Boiler Drum And Its Internals
Boiler Drum And Its InternalsBoiler Drum And Its Internals
Boiler Drum And Its Internals
 
combustion equipment & power cycles
combustion equipment & power cyclescombustion equipment & power cycles
combustion equipment & power cycles
 
SPM Paper 2 Esei: FORCE AND PRESSURE
SPM Paper 2 Esei: FORCE AND PRESSURESPM Paper 2 Esei: FORCE AND PRESSURE
SPM Paper 2 Esei: FORCE AND PRESSURE
 
Evaporator
EvaporatorEvaporator
Evaporator
 
Hptlc (rajat)
Hptlc  (rajat)Hptlc  (rajat)
Hptlc (rajat)
 
Improving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam SystemImproving Efficiency for Boiler and Steam System
Improving Efficiency for Boiler and Steam System
 
A Brief Introduction to Boilers
A Brief Introduction to BoilersA Brief Introduction to Boilers
A Brief Introduction to Boilers
 
4.1 boiler
4.1 boiler4.1 boiler
4.1 boiler
 

Similar a Boiler calculations

J2006 termodinamik 1 unit10
J2006 termodinamik 1 unit10J2006 termodinamik 1 unit10
J2006 termodinamik 1 unit10Malaysia
 
Enthalpy of vaporization of liquid
Enthalpy of vaporization of liquidEnthalpy of vaporization of liquid
Enthalpy of vaporization of liquidNoaman Ahmed
 
Separating and throttling calorimeter for steam
Separating and throttling calorimeter for steamSeparating and throttling calorimeter for steam
Separating and throttling calorimeter for steamSaif al-din ali
 
Thermodynamic diagram
Thermodynamic diagramThermodynamic diagram
Thermodynamic diagramSunny Chauhan
 
Boiler doc 02 principles & heat transfer
Boiler doc 02   principles & heat transferBoiler doc 02   principles & heat transfer
Boiler doc 02 principles & heat transferMars Tsani
 
UNIT-2_Part3_RANKINE CYCLE.pdf
UNIT-2_Part3_RANKINE CYCLE.pdfUNIT-2_Part3_RANKINE CYCLE.pdf
UNIT-2_Part3_RANKINE CYCLE.pdfYOGESH AHIRE
 
J2006 termodinamik 1 unit9
J2006 termodinamik 1 unit9J2006 termodinamik 1 unit9
J2006 termodinamik 1 unit9Malaysia
 
countercurrent heat exchanger lab 2023.pdf
countercurrent  heat exchanger lab 2023.pdfcountercurrent  heat exchanger lab 2023.pdf
countercurrent heat exchanger lab 2023.pdfDimaJawhar
 
Paper on transshipment modelling
Paper on transshipment modellingPaper on transshipment modelling
Paper on transshipment modellingGeorge Cherian
 
types of heat exchangers.pdf
types of heat exchangers.pdftypes of heat exchangers.pdf
types of heat exchangers.pdfhassanzain10
 
Cooling tower full report
Cooling tower full reportCooling tower full report
Cooling tower full reportAzlan Skool
 
Properties of Pure Substances and Property Diagram.pdf
Properties of Pure Substances and Property Diagram.pdfProperties of Pure Substances and Property Diagram.pdf
Properties of Pure Substances and Property Diagram.pdfAishikChowdhury
 
Cost Analysis and optimization
Cost Analysis and optimizationCost Analysis and optimization
Cost Analysis and optimizationNavneet Rohilla
 

Similar a Boiler calculations (20)

J2006 termodinamik 1 unit10
J2006 termodinamik 1 unit10J2006 termodinamik 1 unit10
J2006 termodinamik 1 unit10
 
Enthalpy of vaporization of liquid
Enthalpy of vaporization of liquidEnthalpy of vaporization of liquid
Enthalpy of vaporization of liquid
 
Heat exchanger lab 2
Heat exchanger lab 2Heat exchanger lab 2
Heat exchanger lab 2
 
Separating and throttling calorimeter for steam
Separating and throttling calorimeter for steamSeparating and throttling calorimeter for steam
Separating and throttling calorimeter for steam
 
thermodynamic
thermodynamic thermodynamic
thermodynamic
 
Thermodynamic diagram
Thermodynamic diagramThermodynamic diagram
Thermodynamic diagram
 
Boiler doc 02 principles & heat transfer
Boiler doc 02   principles & heat transferBoiler doc 02   principles & heat transfer
Boiler doc 02 principles & heat transfer
 
UNIT-2_Part3_RANKINE CYCLE.pdf
UNIT-2_Part3_RANKINE CYCLE.pdfUNIT-2_Part3_RANKINE CYCLE.pdf
UNIT-2_Part3_RANKINE CYCLE.pdf
 
J2006 termodinamik 1 unit9
J2006 termodinamik 1 unit9J2006 termodinamik 1 unit9
J2006 termodinamik 1 unit9
 
Hxequns
HxequnsHxequns
Hxequns
 
HHO driven CCPP
HHO driven CCPPHHO driven CCPP
HHO driven CCPP
 
countercurrent heat exchanger lab 2023.pdf
countercurrent  heat exchanger lab 2023.pdfcountercurrent  heat exchanger lab 2023.pdf
countercurrent heat exchanger lab 2023.pdf
 
Paper on transshipment modelling
Paper on transshipment modellingPaper on transshipment modelling
Paper on transshipment modelling
 
types of heat exchangers.pdf
types of heat exchangers.pdftypes of heat exchangers.pdf
types of heat exchangers.pdf
 
Cooling tower full report
Cooling tower full reportCooling tower full report
Cooling tower full report
 
Properties of Pure Substances and Property Diagram.pdf
Properties of Pure Substances and Property Diagram.pdfProperties of Pure Substances and Property Diagram.pdf
Properties of Pure Substances and Property Diagram.pdf
 
Chapter 03 thermo
Chapter 03 thermoChapter 03 thermo
Chapter 03 thermo
 
Cost Analysis and optimization
Cost Analysis and optimizationCost Analysis and optimization
Cost Analysis and optimization
 
marcet boiler
marcet boilermarcet boiler
marcet boiler
 
Single effect evaporation
Single effect evaporationSingle effect evaporation
Single effect evaporation
 

Último

(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...Scintica Instrumentation
 
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRingsTransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRingsSérgio Sacani
 
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot Girls
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot GirlsKanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot Girls
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot GirlsDeepika Singh
 
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIACURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIADr. TATHAGAT KHOBRAGADE
 
The Mariana Trench remarkable geological features on Earth.pptx
The Mariana Trench remarkable geological features on Earth.pptxThe Mariana Trench remarkable geological features on Earth.pptx
The Mariana Trench remarkable geological features on Earth.pptxseri bangash
 
PODOCARPUS...........................pptx
PODOCARPUS...........................pptxPODOCARPUS...........................pptx
PODOCARPUS...........................pptxCherry
 
Concept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdfConcept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdfCherry
 
Plasmid: types, structure and functions.
Plasmid: types, structure and functions.Plasmid: types, structure and functions.
Plasmid: types, structure and functions.Cherry
 
Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.Cherry
 
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRLGwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRLkantirani197
 
LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.Cherry
 
Dr. E. Muralinath_ Blood indices_clinical aspects
Dr. E. Muralinath_ Blood indices_clinical  aspectsDr. E. Muralinath_ Blood indices_clinical  aspects
Dr. E. Muralinath_ Blood indices_clinical aspectsmuralinath2
 
GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body Areesha Ahmad
 
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptxClimate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptxDiariAli
 
Selaginella: features, morphology ,anatomy and reproduction.
Selaginella: features, morphology ,anatomy and reproduction.Selaginella: features, morphology ,anatomy and reproduction.
Selaginella: features, morphology ,anatomy and reproduction.Cherry
 
Role of AI in seed science Predictive modelling and Beyond.pptx
Role of AI in seed science  Predictive modelling and  Beyond.pptxRole of AI in seed science  Predictive modelling and  Beyond.pptx
Role of AI in seed science Predictive modelling and Beyond.pptxArvind Kumar
 
FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.takadzanijustinmaime
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxMohamedFarag457087
 
FAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and SpectrometryFAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and SpectrometryAlex Henderson
 

Último (20)

(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
(May 9, 2024) Enhanced Ultrafast Vector Flow Imaging (VFI) Using Multi-Angle ...
 
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRingsTransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
TransientOffsetin14CAftertheCarringtonEventRecordedbyPolarTreeRings
 
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot Girls
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot GirlsKanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot Girls
Kanchipuram Escorts 🥰 8617370543 Call Girls Offer VIP Hot Girls
 
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIACURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
CURRENT SCENARIO OF POULTRY PRODUCTION IN INDIA
 
The Mariana Trench remarkable geological features on Earth.pptx
The Mariana Trench remarkable geological features on Earth.pptxThe Mariana Trench remarkable geological features on Earth.pptx
The Mariana Trench remarkable geological features on Earth.pptx
 
PODOCARPUS...........................pptx
PODOCARPUS...........................pptxPODOCARPUS...........................pptx
PODOCARPUS...........................pptx
 
Concept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdfConcept of gene and Complementation test.pdf
Concept of gene and Complementation test.pdf
 
Plasmid: types, structure and functions.
Plasmid: types, structure and functions.Plasmid: types, structure and functions.
Plasmid: types, structure and functions.
 
Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.Phenolics: types, biosynthesis and functions.
Phenolics: types, biosynthesis and functions.
 
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRLGwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
Gwalior ❤CALL GIRL 84099*07087 ❤CALL GIRLS IN Gwalior ESCORT SERVICE❤CALL GIRL
 
LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.LUNULARIA -features, morphology, anatomy ,reproduction etc.
LUNULARIA -features, morphology, anatomy ,reproduction etc.
 
Dr. E. Muralinath_ Blood indices_clinical aspects
Dr. E. Muralinath_ Blood indices_clinical  aspectsDr. E. Muralinath_ Blood indices_clinical  aspects
Dr. E. Muralinath_ Blood indices_clinical aspects
 
GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body GBSN - Microbiology (Unit 3)Defense Mechanism of the body
GBSN - Microbiology (Unit 3)Defense Mechanism of the body
 
Clean In Place(CIP).pptx .
Clean In Place(CIP).pptx                 .Clean In Place(CIP).pptx                 .
Clean In Place(CIP).pptx .
 
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptxClimate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
Climate Change Impacts on Terrestrial and Aquatic Ecosystems.pptx
 
Selaginella: features, morphology ,anatomy and reproduction.
Selaginella: features, morphology ,anatomy and reproduction.Selaginella: features, morphology ,anatomy and reproduction.
Selaginella: features, morphology ,anatomy and reproduction.
 
Role of AI in seed science Predictive modelling and Beyond.pptx
Role of AI in seed science  Predictive modelling and  Beyond.pptxRole of AI in seed science  Predictive modelling and  Beyond.pptx
Role of AI in seed science Predictive modelling and Beyond.pptx
 
FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.FS P2 COMBO MSTA LAST PUSH past exam papers.
FS P2 COMBO MSTA LAST PUSH past exam papers.
 
Digital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptxDigital Dentistry.Digital Dentistryvv.pptx
Digital Dentistry.Digital Dentistryvv.pptx
 
FAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and SpectrometryFAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
FAIRSpectra - Enabling the FAIRification of Spectroscopy and Spectrometry
 

Boiler calculations

  • 1. Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection Publications Steam Boiler Technology eBook Espoo 2002 Boiler Calculations Sebastian Teir, Antto Kulla Helsinki University of Technology Department of Mechanical Engineering Energy Engineering and Environmental Protection
  • 2. ii Table of contents Steam/water diagrams used in boiler calculations ...............................................................................1 Temperature-heat (T-Q) diagram.....................................................................................................1 Temperature-entropy (T-s) diagram.................................................................................................2 Pressure-enthalpy (p-h) diagram......................................................................................................3 Enthalpy-entropy (Mollier, h-s) diagram.........................................................................................4 Determination of steam/water parameters ...........................................................................................5 Given parameters .............................................................................................................................5 Pressure losses..................................................................................................................................5 Procedure for determination of specific enthalpies and mass flow rates.........................................6 Superheaters and reheaters...............................................................................................................7 Spray water group mass flow...........................................................................................................7 Calculations of heat load..................................................................................................................8 Evaporator....................................................................................................................................8 Superheater...................................................................................................................................9 Reheater .......................................................................................................................................9 Economizer ..................................................................................................................................9 Air preheater ................................................................................................................................9 Determination of boiler efficiency.....................................................................................................10 Standards........................................................................................................................................10 Major heat losses............................................................................................................................10 Heat loss with unburned combustible gases ..............................................................................10 Heat loss due to unburned solid fuel..........................................................................................10 Heat loss due to wasted heat in flue gases .................................................................................11 Heat loss due to wasted heat in ashes ........................................................................................11 Losses due to heat transfer (radiation) to the environment........................................................12 Losses of blowdown, sootblowing and atomizing steam...........................................................12 Internal power consumption...........................................................................................................12 Calculating boiler efficiency..........................................................................................................12 Direct method.............................................................................................................................13 Indirect method ..........................................................................................................................13 References..........................................................................................................................................14
  • 3. 1 Steam/water diagrams used in boiler calculations Temperature-heat (T-Q) diagram The T-Q diagram is a useful tool for designing heat exchangers. It can also be used to present the heat transfer characteristics of an existing heat exchanger or heat exchanger network. The T-Q diagram consists of two axes: The current stream temperature on the y-axis and the amount of heat transferred on the x-axis. Sometimes the streams are marked with arrowheads to clarify the direction of the streams, but these are not necessary: since heat cannot move from the colder stream to the hotter stream according to the second law of thermodynamics, the directions of the streams are explicitly determined: The hot stream transfers its heat to the cold stream, thus the flow direction of the hot stream is towards lower temperature and the flow direction of the cold stream is towards higher temperatures. For the same reason, the hot stream is always above the cold stream in the T-Q diagram (figure 1). Figure 1: Examples of T-Q diagrams for a parallel flow heat exchanger (left), and a counter (or cross) flow heat exchanger (middle). The hot stream is marked with red color and the cold with blue color. When designing or reviewing heat exchanger networks, the T-Q diagram gets useful. The T-Q diagram is therefore applied when designing boilers; especially the heat exchanger surface arrangement can be clearly visualized with a T-Q diagram (figure 2). 0 200 400 600 800 1000 1200 1400 1600 0 % 10 % 20 % 30 % 40 % 50 % 60 % 70 % 80 % 90 % 100 % Share of heat load [%] Temperature[°C] Flue gas stream Water/steam stream Air stream Furnace Superheater Economizer Air preheater Figure 2: Example of a T-Q diagram representing the heat surfaces in a PCF boiler.
  • 4. 2 Temperature-entropy (T-s) diagram The T-s diagram represents the various phases of steam/water with temperature as a function of the specific entropy. It is often used to visualize steam power processes. The T-s diagram is also commonly used for displaying reversible processes (or real processes simplified as reversible processes), which in the T- s diagram appear as closed curves (loop). The left border, up to the critical point, is the border where the liquid is saturated (figure 3). That is, the water is still liquid and contains no steam. But if we go further right (increase the entropy), steam bubbles starts to form in the water. In other words, saturated water starts to boil when heat is added and entropy is increased. The enclosed region in the middle is the region where water is a mixture of vapor and liquid. Steam that contains water in any form, either as minute droplets, mist or fog, is called wet steam. The quantity called ‘x’ in the diagram Critical point p=constant p=constant p = constant p = constant v=constant v = constant Liquid-vapour region Saturated vapour Saturatedliquid X = 0,2 X = 0,9 Temperature Entropy Figure 3: Simplified T-s diagram of steam/water. represents the amount (percentage by weight) of dry vapor in the wet steam mixture. This quantity is called the quality of steam. For instance, if there is 10 % moisture in the steam, the quality of the steam is 90 % or 0,9. The temperature of wet steam is the same as dry saturated steam at the same pressure. The right border, down from the critical point, is the line where steam is saturated. When steam is heated beyond that border, steam is called superheated. Water boils under constant temperature and pressure, so a horizontal line inside the enclosed region represents a vaporization process in the T-s diagram. The steam/water heating process in the boiler represented by the diagram in figure 2 can also be drawn in a T-s diagram (figure 4), if the boiler pressure is assumed to be e.g. 10 MPa.
  • 5. 3 Figure 4: Detailed T-s diagram of the PCF boiler steam/water heating process from figure 2 (note: color of the steam/water process line is changed from blue to red). Pressure-enthalpy (p-h) diagram Another tool used in boiler calculation is the pressure- enthalpy diagram for steam/water (figure 5). With the p-h diagram it is easy to visualize the partial shares of the total heat load on different heat exchanger surfaces in the boiler: drawing the steam heating process in the boiler onto the p-h diagram will give a horizontal line (if we simplify the process and set pressure losses to zero). Figure 6 shows the same boiler steam/water process from figure 4, drawn in the steam/water p-h diagram. 60 °C 100 °C 200 °C 300 °C 400 °C 500 °C 600 °C 0 500 1000 1500 2000 2500 3000 3500 4000 10 kPa 100 kPa 1 MPa 10 Mpa 20 MPa 50 MPa Enthalpy [kJ/kg] Pressure Critical point Saturatedvapor Saturatedliquid Figure 5: Simplified p-h diagram for steam/water.
  • 6. 4 Figure 6: Detailed p-h diagram of the PCF boiler steam/water heating process (red line) from figure 4. Enthalpy-entropy (Mollier, h-s) diagram The most frequently used tool for determining steam properties is probably the enthalpy- entropy (h-s) diagram, also called Mollier diagram (figure 7). If two properties of the steam state are known (like pressure and temperature), the rest of the properties for steam (enthalpy, entropy, specific volume and moisture content) can be read from the diagram. A more detailed h-s diagram can be found in figure 8. Since the diagram is very large, the diagram is usually found as two versions, consisting of zoomed portions of the original: one for steam properties (figure 7) and another for water properties. Critical point p=constant p=constant T = constant T = constant Liquid-vapour region X = 0,96 X = 0,90 Saturatedvapour Figure 7: Mollier (h-s) diagram, simplified version.
  • 7. 5 Figure 8: Large-scale Mollier h-s diagram for steam. Determination of steam/water parameters Given parameters Normally in a steam boiler design assignment the parameters describing the live (output) steam, e.g. mass flow, pressure and temperature are given. If the steam boiler to be designed has a reheat cycle, also reheat pressure and temperature are given. Reheat steam mass flow can be given as well. These parameters are used to determine the rest of the steam/water parameters. Pressure losses The pressure losses in the heat exchanger units of the boiler are estimated according to the following approximations: • Economizer: the pressure loss is 5-10 % of the pressure of the feedwater entering the economizer. • Evaporator: Once through boilers: in once-through boilers the pressure loss of the evaporator is between 5 and 30 %. Forced and natural circulation boilers: the pressure drop in the evaporator part of drum- based boilers does not affect the pressure loss of the main steam/water flow through the boiler. This means that saturated steam leaving the steam drum has the same pressure as the feedwater entering the steam drum. The pressure loss of the evaporator has to be overcome using the driving force (natural circulation) or circulation pump (forced circulation).
  • 8. 6 • Superheater: the total pressure drop of all superheater packages is less than 10 % of the pressure of the superheated steam. • Reheater: the pressure drop in the reheater is about 5 % of the pressure of reheated steam Pressure losses of connection tubes between different heat transfer surfaces (e.g. between evaporator and superheater) can be neglected in these calculations. Procedure for determination of specific enthalpies and mass flow rates 1. The specific enthalpy of the superheated steam can be determined with an h-s diagram if both the temperature and the pressure of the steam are known. Thus, the specific enthalpies for live (superheated) steam and reheated steam can be calculated. 2. The total pressure loss of the superheater stages should be chosen. Thus, the pressure in steam drum (drum-type boilers) or pressure after evaporator (once-through boilers) can be calculated by adding the pressure loss over the superheater stages to the pressure of the superheated steam. 3. Specific enthalpy of saturated water and steam (in the steam drum) can be read from an h-s diagram or steam tables, as the pressure in the steam drum is known. In once-through boilers the determination of specific enthalpy after the evaporator is based on the temperature. The reason for this is the unclear state of supercritical steam after the evaporator in once-through circulation. The temperature after the evaporator in once-through boilers is typically between 400 and 450 °C. 4. For removal of minerals concentrated in the steam drum, a part of the water in steam drum is removed as blowdown water from the bottom of the steam drum. Normally the mass flow rate of blowdown is 1-3 % of the mass flow rate of feedwater coming into steam drum. 5. In principle, the feedwater coming into steam drum should be saturated water. To prevent the feedwater from boiling in the transportation pipes, the temperature of the feedwater reaching the steam drum is 15-30 °C below saturation temperature. The feedwater is then called subcooled (in contrast to supercooled). When the temperature in the steam drum and the value of subcooling are known, the temperature after the economizer can be determined. The water pressure after the economizer can be assumed to be equal to the pressure in the steam drum and specific enthalpy after the economizer can then be read from a h-s diagram. In once through boilers the pressure after the economizer can be calculated by adding the pressure loss in the evaporator to the pressure after evaporator. The temperature after the evaporator is normally between 300 and 350 °C (can be chosen). Knowing the pressure and the temperature, the specific enthalpy after the evaporator can be defined. 6. The pressure before the economizer can be calculated by adding the pressure loss in the economizer to the feedwater pressure after economizer. The feedwater temperature might be stated in the boiler design assignment. If it is not given, it should be chosen from the range of 200-250 °C. The mass flow rate before the economizer is the blowdown mass flow rate added to the mass flow rate from the steam drum to the superheaters.
  • 9. 7 Superheaters and reheaters Reheating takes usually place in two stages. The pressure before the reheater is the reheated steam pressure added on the pressure loss in the reheater. The steam goes through a high- pressure turbine before it enters the reheater. In the high-pressure turbine, the specific enthalpy of steam decreases according to the isentropic efficiency of the turbine. Isentropic efficiency is normally between 0,8 and 0,9. A part of the low-pressure steam coming from high-pressure turbine continues to the high-pressure feedwater heater (closed-type feedwater heater). However, the mass flow rate of reheated steam is still 85-90 % of that of the live steam. Superheating is often applied in three stages having spray water groups between each other to reduce steam temperature when necessary. Between reheaters, the steam temperature is controlled using other means. Spray water group dimensioning is usually based on a I II III 354 410 435 475 505 535 t °C Heat load Figure 9: An example of the heat load share of superheater stages. steam temperature decrease of 15-40 °C by water spraying. Spray water originates normally from the feedwater line before the economizer. Thus the pressure difference is the pressure loss of the heat transfer surfaces between the economizer inlet and the location of the spray water nozzle. An example of a possible heat load share between the superheater stages is shown in figure 9. Pressure loss in superheaters can be divided into equal partial pressure losses corresponding to each superheater stage. Pressure loss of the spray nozzles can be neglected. Temperature rise over all superheaters can be divided into quite similar parts along the same principle. Spray water group mass flow Normally the mass flow rate of superheated steam (live steam) is known. Thus, mass flow rate calculations start usually by calculating the mass flow rate of spray water to the last spray water group (which is in this example between the second and third superheater stages). The mass flow rates can be solved with energy and mass balance equations. With the equations below (equation 1), the mass flow rate of steam after second superheater stage and mass flow rate of spray water to the last spray water group can be calculated. The mass flow rate of spray water to the first spray water group can be calculated along the same procedure: 1,2, SHIIISHIIISPRAYSPRAYIISHIISHII SHIIISPRAYIISHII hmhmhm mmm ⋅=⋅+⋅ =+ &&& &&& (1) where SHIIm& is the mass flow rate of steam after second superheater stage [kg/s], SPRAYIIm& the mass flow rate of spray water to second spray water group, SHIIIm& the mass flow rate of superheated steam (live steam), 2,SHIIh the specific enthalpy of steam after second superheater
  • 10. 8 stage [kJ/kg], SPRAYh the specific enthalpy of spray water (feedwater), and 1,SHIIIh the specific enthalpy of steam before third superheater stage. Figure 10 shows a flow chart with the symbols visualized of the boiler arrangement used in this calculation model. Reheat IN Air IN Coal IN HP Steam OUT Flue Gas OUT Ash OUT Feedwater IN HP Steam OUT SHIII RHSHI SHII SPRAYII SPRAYI EVAP ECO 12 1212 12 1 2 APH 1 2 Figure 10: Flow chart of the PCF boiler arrangement used in this heat load calculation model. Calculations of heat load When the steam parameters and mass flows have been determined, the heat load of the heat exchanger units can be calculated. The heat load is the heat transferred by a heat exchanger (calculated in kW). Evaporator The heat load of the evaporator part of the boiler can be calculated as: ( ) ( )22 ECOBDECOSHEVAP hhmhhm −′+−′′= &&φ (2) where SHm& is the mass flow of steam before superheater [kg/s], h ′′ the specific enthalpy of saturated steam at steam drum pressure [kJ/kg], 2ECOh the specific enthalpy after economizer BDm& the mass flow of blowdown water from steam drum, and h′ the specific enthalpy of saturated water at steam drum pressure [kg/s].
  • 11. 9 Superheater Normally superheating takes place in three or four stages in a big boiler. This calculation example is based on three stage superheating. The heat load of the first superheater stage is ( )hhm SHISHSHI ′′−= 2, &φ (3) where 2,SHIh is the specific enthalpy of steam after the first superheater stage. In the second superheater stage the heat load added can be calculated as: ( )1,2, SHIISHIISHIISHII hhm −= &φ (4) where SHIIm& is the mass flow of steam before the second superheater [kg/s], 2,SHIIh the specific enthalpy of steam after the second superheater stage [kJ/kg], and 1,SHIIh the specific enthalpy of steam before the second superheater stage. Similarly, the heat load added in third superheater stage can be calculated as: ( )1,2, SHIIISHIIISHIIISHIII hhm −= &φ (5) wher SHIIIm& = Mass flow of steam before third superheater [kg/s], 2,SHIIIh the specific enthalpy of steam after third superheater stage [kJ/kg], and 1,SHIIIh the specific enthalpy of steam before third superheater stage [kJ/kg]. Reheater The heat load of the reheater stage can be calculated as: ( )12 RHRHRHRH hhm −= &φ (6) where RHm& is the mass flow rate of steam in the reheater [kg/s], 2RHh the specific enthalpy of steam after the reheater [kJ/kg] , and 1RHh the specific enthalpy of steam before the reheater. Economizer The heat load of the economizer can be calculated as: ( )12 ECOECOECOECO hhm −= &φ (7) where ECOm& is the mass flow rate of feedwater in the economizer [kg/s], 2ECOh the specific enthalpy of feedwater after the economizer [kJ/kg], and 1ECOh the specific enthalpy of feedwater before the economizer. Air preheater In order to calculate the heat load for the air preheater, we need to know the combustion air mass flow, the temperature of the flue gases and the incoming air. The combustion air fed into air preheater, is taken from upper part of the boiler room. The temperature of the combustion air before the air preheater is therefore between 25 and 40°C (in Finnish conditions). The flue gases
  • 12. 10 exiting the boiler are usually kept above 130-150 °C in order to prevent corrosion. The enthalpies can be taken from tables: ( )12 APHAPH FUEL AIR FUELAPH hh m m m −⋅⋅= & & &φ (8) where FUELm& is the mass flow rate of fuel fed into the boiler [kg/s], FUEL AIR m m & & the mass flow rate of combustion air divided by the mass flow rate of fuel fed into the boiler, 1APHh the specific enthalpy of combustion air before the air preheater [kJ/kg], and 2APHh the specific enthalpy of combustion air after the air preheater. Determination of boiler efficiency Standards There are two main standards used for definition of boiler efficiency. Of those, the German DIN 1942 standard employs the lower heating value (LHV) of a fuel and is widely used in Europe. The American ASME standard is based on higher heating value (HHV). However, this chapter calculates the efficiency according to the DIN 1942 standard. [1] It should be marked that with the DIN standard it is possible to reach boiler efficiencies over 100 %, if the condensation heat of the flue gases is recovered. Major heat losses Heat loss with unburned combustible gases The typical unburned combustible gases are carbon monoxide (CO) and hydrogen (H2). In large boilers usually only carbon monoxide can be found in significant amounts in flue gases. Assuming that flue gases contain only these two gases, the losses [kW]can be calculated as: 22 ,,1 HlHCOlCOL HmHm ⋅+⋅= &&φ (9) where COm& is the mass flow of carbon monoxide [kg/s], 2Hm& the mass flow of hydrogen, COlH , the lower heating value (LHV) of carbon monoxide (10,12 MJ/kg), and 2,HlH the lower heating value (LHV) of hydrogen (119,5 MJ/kg). If a relevant amount of some other flue gas compound can be found in the flue gases, it should be added to the equation. Heat loss due to unburned solid fuel Unburned fuel can exit the furnace as well as bottom ash or fly ash. The heating value of ashes can be measured in a specific laboratory test. The losses [kW] of unburned solid fuels can be calculated as: ubslubsL Hm ,2 ⋅= &φ (10)
  • 13. 11 where ubsm& is the total mass flow of unburned solid fuel (bottom ash and fly ash in total) [kg/s], and ubslH , the lower heating value (LHV) of unburned solid fuel (fly ash and bottom ash in total) [kJ/kg]. Some estimates of the losses with unburned solid fuels are presented in table 1: Table 1: Estimates of losses with unburned solid fuel. Boiler type Heat loss per heat input of fuel Oil fired boiler 0,2 - 0,5 % Coal fired boiler, dry ash removal 3 % Coal fired boiler, molten ash removal about 2 % Grate boiler 4-6 % Heat loss due to wasted heat in flue gases Flue gases leave the furnace in high temperature and thus they carry significant amount of energy away from boiler process. To decrease flue gas losses, flue gas exit temperature should be decreased. However, the acid dew point of flue gases restricts the flue gas temperature to about 130-150 °C for sulphur containing fuels. The losses caused by the sensible heat of flue gases can be calculated as: ∑ ⋅⋅= i i fuel i fuelL h m m m & & &3φ (11) where fuelm& is the fuel mass flow [kg/s], im& the mass flow of a flue gas component, and ih the specific enthalpy of a flue gas component (e.g. CO2) [kJ/kg]. Heat loss due to wasted heat in ashes Ash can exit the furnace either as bottom ash from bottom of the furnace or as fly ash with flue gases. The losses related to the sensible heat of ash can be calculated as: fafapfababapbaL TcmTcm ∆⋅⋅+∆⋅⋅= ,,4 &&φ (12) where bam& is the mass flow of the bottom ash [kg/s], bapc , the specific heat of the bottom ash [kJ/(kgK)], baT∆ the temperature difference between the bottom ash temperature and the reference temperature [°C], fam& the mass flow of fly ash, fapc , the specific heat of fly ash, faT∆ the temperature difference between the fly ash temperature and the reference temperature [°C]. Usually the reference temperature is 25 °C. In recovery boilers the bottom ash is removed as molten ash in temperature of about 700-800 °C. In addition, the amount of bottom ash divided by the amount of fuel is about 40 %. The loss of sensible heat of ash is therefore of great importance in recovery boilers.
  • 14. 12 Losses due to heat transfer (radiation) to the environment The main form of heat transfer from boiler to boiler room is radiation. It is proportional to the outer surface area of the boiler and is usually 200-300 W/(m2K) for a well-insulated boiler having its outer surface temperature below 55 °C. Another possibility to determine the heat transfer losses to the environment is to use a table from the DIN 1942 standard, presented in table 2. Table 2: Estimations of heat transfer losses by radiation. [1] Mass flow rate of steam [t/h] Combustion method 10 20 40 60 80 100 200 400 600 800 Pulverized firing - 1,3 1,0 0,9 0,75 0,7 0,55 0,4 0,35 0,3 Grate 1,5 1,1 0,9 0,7 - - - - - -Loss [%] Oil/gas fired boiler 1,3 0,9 0,7 0,6 0,55 0,4 0,3 0,25 0,2 0,2 Losses of blowdown, sootblowing and atomizing steam Blowdown water from the steam drum and sootblowing steam (used to remove soot from heat exchanger surfaces within the boiler) use a part of the steam produced by the boiler. This lowers the boiler efficiency. In addition, steam is sometimes also used to atomize fuel in the burners. The losses can be calculated as: atomizingatomizingsbsbbdL hmhmhm ⋅+⋅+′⋅= &&&6φ (13) bdm& is the mass flow of blowdown water [kg/s], h′ is the specific enthalpy of saturated water (blowdown water from steam drum) [kJ/kg], sbm& is the mass flow of sootblowing steam, sbh is the specific enthalpy of steam used for sootblowing (when leaving the boiler), atomizingm& is the mass flow of atomizing steam, and atomizingh the specific enthalpy of steam used for atomizing the fuel (when leaving the boiler) [kJ/kg]. Internal power consumption The power plant itself consumes a part of the electricity produced. This is due to the various auxilary equipments required, like feedwater pumps, circulation pumps and air/flue gas blowers. In forced circulation boilers the share of electricity consumed by the circulation pump is about 0,5 % of the electricity produced by the plant. Normally the internal power consumption is about 5 % of the electricity produced by the power plant. Since the power used is electrical (and taken from the grid), the internal power consumption share is reduced from the final boiler efficiency in boiler calculations. Calculating boiler efficiency There are two different means of calculating the boiler efficiency: The direct method and the indirect method.
  • 15. 13 Direct method In the direct method, the boiler efficiency is directly defined by the exploitable heat output from the boiler and by the fuel power of the boiler: input output φ φ η = (14) where outputφ is the exploitable heat output from boiler, and inputφ the fuel power of the boiler. Indirect method Indirect method determines the efficiency of a boiler by the sum of the major losses and by the fuel power of the boiler: input losses φ φ η −=1 (15) where lossesφ is the sum of the major losses within the boiler, and inputφ is the fuel power of the boiler. The indirect method provides a better understanding of the effect of individual losses on the boiler efficiency.
  • 16. 14 References 1. DIN 1942. "Abnahmeversuche an Dampferzeugern".