SlideShare una empresa de Scribd logo
1 de 41
Descargar para leer sin conexión
362
SUBMITTED TO SUBMITTED BY
DR. VINEET KUMAR VISHAL SINGH
00320903613
MAE 6TH SEMESTER
IN-HOUSE TRAINING REPORT
PNEUMATIC SYSTEM
ETAT-362
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | i
Table of Contents
Acknowledgement iii
1. Introduction 1
1.1 Comparison of Hydraulic and Pneumatic System
1.2 Advantages & Disadvantages of Pneumatic System
1.3 Applications
1.4 Components
2. Valves 9
2.1 Direction Control Valve
2.2 Methods of Actuation
2.3 Non-Return Valves
2.4 Flow Control Valves
2.5 Pressure Control Valves
3. Compressors 22
3.1 Piston
3.2 Double Acting
3.3 Multistage
3.4 Combined Two Stage
3.5 Diaphragm
3.6 Screw
3.7 Rotary
3.8 Lobe
3.9 Dynamic
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | ii
4. Actuators 28
4.1 Single Acting
4.2 Double Acting
4.3 Cylinder End Cushions
4.4 Gear Motor
4.5 Vane Motor
4.6 Limited Rotation Actuators
4.7 Speed Control
5. Case Study 34
References 37
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | iii
Acknowledgement
I take this opportunity to express our sincere gratitude to the people who
have been helpful in the successful completion of our In-house training and
this project. I would like to show my greatest appreciation to the highly
esteemed and devoted technical staff, supervisors of our College. We are highly
indebted to them for their tremendous support and help during the completion
of our training and project.
I am grateful to my teachers Dr. Vineet Kumar and Mr. Urfi Khan and who
granted us the permission of in house training in the College. We would like to thanks
to all those peoples who directly or indirectly helped and guided us to complete our
training, including the instructors and technical officers of the Pneumatics Lab.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 1
Introduction
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 2
Pneumatics may be defined as branch of engineering science which deals with
the study of the behaviour and application of compressed air to power machine or
control or regulate machines. It deals with generation, transmission and control of
power using pressurized air. Gas in a pneumatic system behaves like a spring since it
is compressible.
Any gas can be used in pneumatic system but air is the most usual, for obvious reasons.
Exceptions are most likely to occur on aircraft and space vehicles where an inert gas
such as nitrogen is preferred or the gas is one which is generated on board. Actuation
of the controls can be manual, Pneumatic or Electrical actuation.
DIFFERENCES BETWEEN HYDRAULIC
AND PNEUMATIC SYSTEMS
One of the main differences between the two systems is that in pneumatics, air
is compressible. In hydraulics, liquids are not. Other two distinct differences are given
below.
The pneumatic systems have two main features:
 Pneumatic systems use compressed gas such as air or nitrogen to perform work
processes.
 Pneumatic systems are open systems, exhausting the compressed air to
atmosphere after use.
The hydraulic systems also have two main features:
 Hydraulic systems use liquids such as oil and water to perform work processes.
 Hydraulic systems are closed systems, recirculating the oil or water after use.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 3
Table 1.1 Comparison between Hydraulic and Pneumatic Systems
S.NO. HYDRAULIC SYSTEM PNEUMATIC SYSTEM
1 It employs a pressurized liquid as fluid It employs a compressed gas usually
air as a fluid
2 Oil hydraulics system operates at
pressure upto 700 bar
Pneumatic systems usually operate at
5 to 10 bar
3 Generally designed for closed systems Pneumatic systems are usually
designed as open system
4 System get slowdown of leakage
occurs
Leakage does not affect the system
much more
5 Valve operation are difficult Easy to operate the valves
6 Heavier in weight Light in weight
7 Pumps are used to provide pressurized
liquids
Compressors are used to provide
compressed gas
8 System is unsafe to fire hazards System is free from fire hazards
9 Automatic lubrication is provided Special arrangements for lubrication
needed.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 4
ADVANTAGES OF
PNEUMATIC SYSTEM
 Low inertia effect of pneumatic components due to low density of air.
 Pneumatic Systems are light in weight.
 Operating elements are cheaper and easy to operate
 Power losses are less due to low viscosity of air
 High output to weight ratio
 Pneumatic systems offers a safe power source in explosive environment
 Leakage is less and does not influence the systems. Moreover, leakage is not
harmful
DISADVANTAGES OF
PNEUMATIC SYSTEMS
 Suitable only for low pressure and hence low force applications
 Compressed air actuators are economical up to 50 KN only
 Generation of the compressed air is expensive compared to electricity
 Exhaust air noise is unpleasant and silence has to be used
 Rigidity of the system is poor
 Weight to pressure ratio is large
 Less precise. It is not possible to achieve uniform speed due to compressibility
of air
 Pneumatic systems is vulnerable to dirt and contamination
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 5
APPLICATIONS
Pneumatic systems are used in many applications. In construction, it is
indispensable source of power for such tools as air drills, hammers, wrenches, and even
air cushion supported structures, not to mention the many vehicles using air
suspension , braking and pneumatic tires.
In manufacturing, air is used to power high speed clamping, drilling, grinding, and
assembly using pneumatic wrenches and riveting machines. Plant air is also used to
power hoists and cushion support to transport loads through the plant.
Many recent advances in air – cushion support are used in the military and commercial
marine transport industry.
Table 1.2 Applications of Pneumatic Systems
MATERIAL HANDLING MANUFACTURING OTHER
APPLICATIONS
Clamping
Shifting
Positioning
Orienting
Feeding
Ejection
Braking
Bonding
Locking
Packaging
Feeding
Sorting
Stacking
Drilling
Turning
Milling
Sawing
Finishing
Forming
Quality Control
Stamping
Embossing
Filling
Aircraft
Cement Plants
Chemical Plants
Coal Mines
Cotton Mills
Diaries
Forge Shops
Machine Tools
Door Control
Turning Parts
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 6
COMPONENTS
Pneumatic system carries power by employing compressed gas generally air as
a fluid for transmitting the energy from an energy-generating source to an energy –
use point to accomplish useful work.
Figure 1.1 Arrangement of Pneumatic System
a) Air filters
These are used to filter out the contaminants from the air.
b) Compressor
Compressed air is generated by using air compressors. Air compressors are
either diesel or electrically operated. Based on the requirement of compressed
air, suitable capacity compressors may be used.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 7
c) Air cooler
During compression operation, air temperature increases. Therefore coolers are
used to reduce the temperature of the compressed air.
d) Dryer
The water vapor or moisture in the air is separated from the air by using a dryer.
e) Control Valves
Control valves are used to regulate, control and monitor for control of direction
flow, pressure etc.
f) Air Actuator
Air cylinders and motors are used to obtain the required movements of
mechanical elements of pneumatic system.
g) Electric Motor
Transforms electrical energy into mechanical energy. It is used to drive the
compressor
h) Receiver tank
The compressed air coming from the compressor is stored in the air receiver.
FUNCTIONS OF COMPONENTS
 Pneumatic actuator converts the fluid power into mechanical power to do useful
work.
 Compressor is used to compress the fresh air drawn from the atmosphere.
 Storage reservoir is used to store a given volume of compressed air.
 Valves are used to control the direction, flow rate and pressure of compressed
air.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 8
 External power supply (Motor) is used to drive the compressor.
 Piping system carries the pressurized air from one location to another.
Air is drawn from the atmosphere through air filter and raised to required pressure
by an air compressor. As the pressure rises, the temperature also rises and hence air
cooler is provided to cool the air with some preliminary treatment to remove the
moisture.
Then the treatment pressurized air needs to get stored to maintain the pressure. With
the storage reservoir, a pressure switch is fitted to start and stop the electric motor
when pressure falls and reached the required level, respectively.
The cylinder movement is controlled by pneumatic valve. One side of the pneumatic
valve is connected to the compressed air and silencers for the exhaust air and the other
side of the valve is connected to port A and Port B of the cylinder.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 9
Valves
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 10
Valve are defined as devices to control or regulate the commencement,
termination and direction and also the pressure or rate of flow of a fluid under pressure
which is delivered by a compressor or vacuum pump or is stored in a vessel.
FUNCTION
 They control the supply of air to power units, example cylinders
 They provide signal which govern the sequence of operation
 They act as interlock and safety devices
Valves used in pneumatics mainly have a control
function that is when they act on some process,
operation or quantity to be stopped. A control
function requires control energy, it being desirable
to achieve the greatest possible effect with the least
effort. The form of control energy will be dictated
by the valve’s mode of actuation and may be
manual, mechanical, electrical hydraulic or
pneumatic.
Figure 2.1 Simple Valve
TYPES
1. Direction control valve
2. Non return valves
3. Flow control valves
4. Pressure control valves
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 11
DIRECTION CONTROL VALVES
In order to control the movement of air actuators, compressed air has to be regulated,
controlled and reversed with a predetermined sequence. Pressure and flow rates of
the compressed air has to be controlled to obtain the desired level of force and speed
of air actuators.
The function of directional control valve is to control the direction of flow in the
pneumatic circuit. DCVs are used to start, stop and regulate the direction of air flow
and to help in the distribution of air in the required line.
TYPES
1. Based on construction
 Poppet or seat valves
 Ball seat valve
 Disc seat valve
 Diaphragm Valves
 Sliding spool valves
 Longitudinal slide valve
 Suspended spool valves
 Rotary spool valves
o Two way valves
o Three way valves
o Four way valves
2. Based on methods of Actuation
 Mechanical
 Electrical
 Pneumatic
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 12
3. Based on Size of the port
Size refers to a valve’s port size. The port sizes are designated as M5, G1/8, and
G1/4 etc. M refer to Metric thread, G refer to British standard pipe (BSP) thread.
4. Based on mounting styles
 Sub base
 Manifold
 In-line
 Valve island
Table 2.1 Port Marking
PORT OLD (LETTER)
SYSTEM
ISO (NUMBER)
SYSTEM
REMARKS
Pressure Port P 1 Supply Port
Working Port A 2 3/2 DCV
Working Ports A,B 4,2 4/2 or 5/2 DCV
Exhaust Port R 3 3/2 DCV
Exhaust Ports R,S 5,3 5/2 DCV
Pilot Ports Z or Y 12 Pilot Line (Flow 1-2)
Pilot Ports Z 14 Pilot Line (Flow 1-4)
Pilot Ports Z or Y 10 Pilot Line (No Flow)
Internal Pilot Ports Pz, Py 81,91 Auxiliary Pilot Line
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 13
PORT AND POSITION
2/2 directional Valve
Ports
Position
3/2 Directional Control Valve
(Normally Closed)
3/2 Directional Control Valve
(Normally Open )
4/2 Direction Control Valve
5/2 Direction Control Valve
5/3 Direction Control Valve
Table 2.2 Ports in different positions
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 14
POPPET DIRECTION CONTROL VALVES
A. Ball seat valve
In a poppet valve, discs, cones or balls are used to control flow. In a
simple 2/2 normally closed valve. If the push button is pressed, ball will lift off
from its seat and
allows the air to flow
from port P to port B.
When the push
button is released,
spring force and air
pressure keeps the
ball back and closes
air flow from port P to
port B.
B. Disc seat poppet valve
In a disc type 3/2 way DCV, When push button is released, ports 1 and 3
are connected via hollow
pushbutton stem. If the push
button is pressed, port 3 is first
blocked by the moving valve
stem and then valve disc is
pushed down so as to open
the valve thus connecting port
1 and 3. When the push
button is released, spring and
air pressure from port 1 closes
the valve.
Figure 2.2 Ball Seat Valve
Figure 2.3 Disc Seat Poppet Valve
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 15
C. Diaphragm valves
The diaphragm between the actuator and valve body hermetically
isolates the fluid from the actuator.
Closed position: When
de-energized, the valve is
closed by spring action
Open position: If the
actuator is pressurized by
the control pressure, it
simultaneously lifts the
control piston and the
valve spindle to open the
valve.
The valves are maintenance-free and extremely robust and can be retrofitted
with a comprehensive range of accessories, e.g. electrical position feedback,
stroke limitation or manual override.
Advantages of
poppet valves
 Response of poppet valve is very fast- short stroke to provide maximum flow
opening
 They give larger opening (larger flow) of valves for a small stroke
 The valve seats are usually simple elastic seals so wear is minimum
 They are insensitive to dust and dirt and they are robust, seats are self-cleaning
 Maintenance is easy and economical.
 They are inexpensive
Figure 2.4 Diaphragm Valve
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 16
 They give longer service life: short stroke and few wearing parts give minimum
wear and maximum life capabilities
Disadvantages of
poppet valves
 The actuating force is relatively high, as it is necessary to overcome the force of
the built in reset spring and the air pressure.
 They are noisy if flow fluctuation is large.
SPOOL DIRECTION CONTROL VALVES
A. Pneumatically actuated 3/2 DCV
In normal position, the working port (2) is closed to the pressure port (1)
and open to the exhaust port (3). When the compressed air is applied through
the pilot port (12), the spool is moved against the spring.
In the actuated position, the
working port (2) is open to
the pressure port (1) and
closed to the exhaust port
(3). Thus, the application of
the compressed air to the
port 12 causes the pressure
port (1) to be connected to
the working port (2).
Figure 2.5 Pneumatically Actuated 3/2 DCV
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 17
B. Pneumatically actuated 4/2 DCV
In a 4/2 way valve pneumatically operated DCV, Switch over is effected
by direct application of pressure. If compressed air is applied to pilot spool
through control port 12, it connects port 1 with 2 and 4 is exhausted through
port 3. If the pilot pressure is applied to port 14, then 1 is connected with 4 and
line 2 exhausted through port 3. On disconnecting the compressed air from the
control line, the pilot spool remains in its current position until spool receives a
signal from the other control side.
C. Suspended Disc Direction Control Valves
This valve is quite similar to 4/2 way spool valve. In this design disc is
used instead of a
spool. This
suspended disc can
be moved by pilot
pressure or by
solenoid or by
mechanical means.
In this design, main
disc connects port 1
to either port 4 or 2.
The secondary seat
discs seal the exhaust port 3 whichever is not functional. These values are
generally provided with manual override to manually move the cylinder.
Figure 2.6 Pneumatically Actuated 4/2 DCV
Figure 2.7 Suspended Disc DCV
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 18
D. Rotary valves
The rotary spool directional control valve has a round core with one or
more passages or recesses in it. The core is mounted within a stationary sleeve.
As the core is rotated within the stationary sleeve, the passages or recesses
connect or block the ports in the sleeve. The ports in the sleeve are connected
to the appropriate lines of the fluid system.
By rotating the handle, core gets connected to different holes to give the
required configuration of the valve. This type of the valve can be directly
mounted on panel using bolt.
METHODS OF ACTUATION
The methods of actuation of pneumatic directional control valves depend upon the
requirements of the task. The types of actuation vary;
 Manually actuated
 Mechanically actuated
 Pneumatically actuated
 Electrically actuated
 Combined actuation
Figure 2.8 Rotary Valve
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 19
Table 2.3 Different types of Actuation Method
TYPE OF ACTUATION TYPE OF CONTROL SYMBOL
Manual
General
Push button
Distant lever operated
Foot pedal
Mechanical
Spring return
Spring centred
Roller Operated
Idle Roller
Pneumatic
Direct
Indirect, Pilot Operated
Electrical
Single Solenoid
Double Solenoid
Combined Double Solenoid with pilot
operated
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 20
NON RETURN VALVES
Non return valves permit flow of air in one direction only, the other direction through
the valve being at all times blocked to the air flow. Mostly the valves are designed so
that the check is additionally loaded by the downstream air pressure, thus supporting
the non-return action.
TYPES
 Check valve
 Shuttle valve
 Restrictor check valve
 Quick exhaust valve
 Two pressure valve
FLOW CONTROL VALVES
A flow control valve regulates the rate of air flow. The control action is limited to the
air flow passing through the valve when it is open, maintaining a set volume per unit
of time.
Figure 2.9 Non-Return Valves
Figure 2.10 Flow Control Valves
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 21
PRESSURE CONTROL VALVE
Compared with hydraulic systems, few pressure control valves are brought into use in
pneumatics. Pressure control valves control the pressure of the air flowing through the
valve or confined in the system controlled by the valve.
There are three types of pressure control valves
1. Pressure limiting valve
2. Pressure sequence valve
3. Pressure regulator or pressure reducing valve
Figure 2.11 Pressure Control
Valves
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 22
Compressors
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 23
It is a mechanical device which converts mechanical energy into fluid energy.
The compressor increases the air pressure by reducing its volume which also increases
the temperature of the compressed air. The compressor is selected based on the
pressure it needs to operate and the delivery volume.
The compressor can be classified into two main types
a. Positive displacement compressors
b. Dynamic displacement compressor
Positive displacement compressors include piston type, vane type, diaphragm type and
screw type.
PISTON COMPRESSORS
Piston compressors are commonly
used in pneumatic systems. It produces one
pulse of air per piston stroke. As the piston
moves down during the inlet stroke the inlet
valve opens and air is drawn into the cylinder.
As the piston moves up the inlet valve closes
and the exhaust valve opens which allows the
air to be expelled. The valves are spring
loaded. The single cylinder compressor gives
significant amount of pressure pulses at the
outlet port. The pressure developed is about
3-40 bar. Figure 3.1 Piston Compressor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 24
DOUBLE ACTING COMPRESSOR
The pulsation of air can be reduced by using double acting compressor. It has
two sets of valves and a crosshead. As the piston moves, the air is compressed on one
side whilst on the other side of the piston, the air is sucked in. Due to the reciprocating
action of the piston, the air is compressed and delivered twice in one piston stroke.
Pressure higher than 30bar can be produced
MULTISTAGE COMPRESSOR
As the pressure of the air increases, its temperature rises. It is essential to reduce
the air temperature to avoid damage of compressor and other mechanical elements.
The multistage compressor with intercooler in-between. It is used to reduce the
temperature of compressed air during the compression stages. The inter-cooling
reduces the volume of air which used to increase due to heat. The compressed air from
the first stage enters the
intercooler where it is
cooled. This air is given
as input to the second
stage where it is
compressed again. The
multistage compressor
can develop a pressure
of around 50bar.
Figure 3.2 Double Acting Compressor
Figure 3.3 Multistage Compressor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 25
COMBINED TWO STAGE COMPRESSORS
In this type, two-stage
compression is carried out by using
the same piston. Initially when the
piston moves down, air is sucked in
through the inlet valve. During the
compression process, the air moves
out of the exhaust valve into the
intercooler. As the piston moves
further the stepped head provided on
the piston moves into the cavity thus
causing the compression of air. Then,
this is let out by the exhaust port.
DIAPHRAGM COMPRESSOR
In piston compressors the
lubricating oil from the
pistons walls may
contaminate the compressed
air. The contamination is
undesirable in food,
pharmaceutical and chemical
industries. For such
applications diaphragm type
compressor can be used.
The piston reciprocates by a motor driven crankshaft. As the piston moves down it
pulls the hydraulic fluid down causing the diaphragm to move along and the air is
sucked in. When the piston moves up the fluid pushes the diaphragm up causing the
ejection of air from the outlet port. Since the flexible diaphragm is placed in between
the piston and the air no contamination takes place.
Figure 3.4 Combined Two Stage Compressor
Figure 3.5 Diaphragm Compressor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 26
SCREW COMPRESSOR
Piston compressors are used when
high pressures and relatively low
volume of air is needed. The system
is complex as it has many moving
parts. For medium flow and
pressure applications, screw
compressor can be used. It is simple
in construction with less number of
moving parts. The air delivered is
steady with no pressure pulsation. It
has two meshing screws. The air
from the inlet is trapped between the meshing screws and is compressed. The contact
between the two meshing surface is minimum, hence no cooling is required. These
systems are quite in operation compared to piston type. The screws are synchronized
by using external timing gears.
ROTARY VANE COMPRESSORS
The principle of operation of vane
compressor is similar to the
hydraulic vane pump. The
unbalanced vane compressor
consists of spring loaded vanes
seating in the slots of the rotor.
The pumping action occurs due to
movement of the vanes along a
cam ring. The rotor is eccentric to
the cam ring. As the rotor rotates,
the vanes follow the inner surface
of the cam ring. The space between the vanes decreases near the outlet due to the
eccentricity. This causes compression of the air. These compressors are free from
pulsation. If the eccentricity is zero no flow takes place.
Figure 3.6 Screw Compressor
Figure 3.7 Rotary Vane Compressor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 27
LOBE COMPRESSOR
The lobe compressor is used when high
delivery volume but low pressure is
needed. It consists of two lobes with one
being driven and the other driving. It is
similar to the Lobe pump used in hydraulic
systems. The operating pressure is limited
by leakage between rotors and housing.
As the wear increases during the
operation, the efficiency falls rapidly.
DYNAMIC COMPRESSORS
When very large volume of compressed air is required in applications such as
ventilators, combustion system and pneumatic powder blower conveyors, the dynamic
compressor can be used. The pressure needed is very low in such applications. The
impeller rotates at a high speed. Large volume of low pressure air can be provided by
blowers. The blowers draw the air in and the impeller flings it out due to centrifugal
force. Positive displacement compressors need oil to lubricate the moving parts,
whereas the dynamic compressors have no such need. The efficiency of these
compressors is better than that of reciprocating types.
Figure 3.8 Lobe Compressor
Figure 3.9 Dynamic Compressor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 28
Actuators
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 29
Actuators are output devices which convert energy from pressurized hydraulic
oil or compressed air into the required type of action or motion. In general, hydraulic
or pneumatic systems are used for gripping and/or moving operations in industry.
These operations are carried out by using actuators.
Actuators can be classified into three types.
1. Linear actuators: These devices convert hydraulic/pneumatic energy into linear
motion.
2. Rotary actuators: These devices convert hydraulic/pneumatic energy into rotary
motion.
3. Actuators to operate flow control valves: these are used to control the flow and
pressure of fluids such as gases, steam or liquid.
The construction of hydraulic and pneumatic linear actuators is similar. However they
differ at their operating pressure ranges. Typical pressure of hydraulic cylinders is
about 100 bar and of pneumatic system is around 10 bar.
SINGLE ACTING CYLINDER
These cylinders produce
work in one direction of motion
hence they are named as single
acting cylinders. The
compressed air pushes the
piston located in the cylindrical
barrel causing the desired
motion. The return stroke takes
place by the action of a spring.
Generally the spring is
provided on the rod side of the
cylinder.
Figure 4.1 Single Acting Cylinder
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 30
DOUBLE ACTING CYLINDER
The main parts of a hydraulic double acting cylinder are: piston, piston rod,
cylinder tube, and end caps. The piston rod is connected to piston head and the other
end extends out of the cylinder. The piston divides the cylinder into two chambers
namely the rod end side and piston end side. The seals prevent the leakage of oil
between these two
chambers. The cylindrical
tube is fitted with end
caps. The pressurized oil,
air enters the cylinder
chamber through the
ports provided. In the rod
end cover plate, a wiper
seal is provided to
prevent the leakage of oil
and entry of the
contaminants into the
cylinder.
The combination of wiper seal, bearing and sealing ring is called as cartridge assembly.
The end caps may be attached to the tube by threaded connection, welded connection
or tie rod connection. The piston seal prevents metal to metal contact and wear of
piston head and the tube. These seals are replaceable. End cushioning is also provided
to prevent the impact with end caps.
CYLINDER END CUSHIONS
Double acting cylinders generally contain cylinder cushions at the end of the
cylinder to slow down the movement of the piston near the end of the stroke.
Cushioning arrangement avoids the damage due to the impact occurred when a fast
moving piston is stopped by the end caps. Deceleration of the piston starts when the
tapered plunger enters the opening in the cap and closes the main fluid exit. This
restricts the exhaust flow from the barrel to the port. This throttling causes the initial
speed reduction. During the last portion of the stroke the oil has to exhaust through
an adjustable opening since main fluid exit closes. Thus the remaining fluid exists
Figure 4.2 Double Acting Cylinder
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 31
through the cushioning valve.
Amount of cushioning can be
adjusted by means of cushion
screw. A check valve is
provided to achieve fast break
away from the end position
during retraction motion. A
bleed screw is built into the
check valve to remove the air
bubbles present in a hydraulic
type system.
GEAR MOTOR: A ROTARY ACTUATOR
It consists of two inter meshing gears inside
a housing with one gear attached to the
drive shaft. The air enters from the inlet,
causes the rotation of the meshing gear due
to difference in the pressure and produces
the torque. The air exists from the exhaust
port. Gear motors tend to leak at low speed,
hence are generally used for medium speed
applications.
VANE MOTOR: A ROTARY ACTUATOR
A rotary vane motor consists of a
rotor with sliding vanes in the slots
provided on the rotor. The rotor is
placed eccentrically with the housing.
Air enters from the inlet port, rotates
the rotor and thus torque is produced.
Air is then released from the exhaust
port (outlet).
Figure 4.3 Cylinder End Cushions
Figure 4.4 Gear Motor
Figure 4.5 Vane Motor
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 32
LIMITED ROTATION ACTUATORS
It consists of a single rotating vane connected to output shaft. It is used for double
acting operation and has a maximum angle of rotation of about 270°. These are
generally used to actuate dampers in robotics and material handling applications.
Other type of limited rotation actuator is a rack and pinion type actuator.
SPEED CONTROL
For an actuator, the operational speed is determined by the fluid flow rate and the
cylinder actuator area or the motor displacement. The speed can only be controlled by
adjusting the fluid flow to the actuator, because the physical dimension of the actuator
is fixed. Since the air is compressible, flow control is difficult as compared to the
hydraulic system. There are various ways of controlling the fluid flow.
Figure 4.6 Limited Rotation Actuator
Figure 4.7 Speed Control Arrangement
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 33
One of the method is that a pump having fixed displacement is kept along an actuator.
Thus, the fluid goes either to the pump or the actuator. When the direction control
valve moves from its centre position the actuator of area ‘A’, the piston moves with a
velocity.
v = 𝑉/𝐴
If the pump delivery volume ‘V’ can be adjusted by altering swash plate angle of a
piston pump or by using a variable displacement vane pump, no further speed control
will be needed.
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 34
Case Study
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 35
To design a pneumatic circuit to accomplish a simple operation where a double-
acting cylinder is used to transfer parts from a magazine. The cylinder is to be advanced
either by operating a push button or by a foot pedal. Once the cylinder is fully advanced,
it is to be retracted to its initial position. A 3/2-way roller lever valve is to be used to
detect the full extension of the cylinder.
COMPONENTS USED
The pneumatic components which can be used to implement the mentioned task are
as follows:
 Double acting cylinder
 3/2 push button valve
 3/2 roller valve
 Shuttle valve
 3/2 foot pedal actuated valve
 5/3 pneumatic actuated direction control valve
 Compressed air source and connecting piping
Figure 5.1 Magazine Ejection Setup
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 36
WORKING
According to the problem stated, upon actuation of either the push button of valve
(S1) or the foot pedal valve (S2), a signal is generated at 1 or 1(3) side of the shuttle
valve. The OR condition is met and the signal is passed to the control port 14 of the
direction control valve (V2). Due to this signal, the left position of V2 is actuated and
the flow of air starts. Pressure is applied on the piston side of the cylinder (A) and the
cylinder extends. If the push button or pedal valve is released, the signal at the
direction control valve (V2) port is reset. Since DCV (V2) is a double pilot valve, it has
a memory function which doesn’t allow switching of positions. As the piston reaches
the rod end position, the roller valve (S3) is actuated and a signal is applied to port 12
of the DCV (V2). This causes actuation of right side of DCV (V2). Due to this actuation,
the flow enters at the rod-end side of the cylinder, which pushes the piston towards
left and thus the cylinder retracts.
Figure 5.2 Magazine Ejection Mechanism
V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 37
References
 Boltan, W., Mechatronics: electronic control systems in mechanical and electrical
engineering, Longman, Singapore, 1999
 Boucher, T. O., Computer automation in manufacturing - an Introduction,
Chapman and Hall, 1996
 Blackburn,J. F.,G.Reethof, and J. L. Shearer, Fluid Power Control, New York:
Technology Press of M. I. T. and Wiley
 Hasebrink J.P., and Kobler R., “Fundamentals of Pneumatics/electropeumatics”,
FESTO Didactic publication No. 7301, Esslingen Germany, 1979.

Más contenido relacionado

La actualidad más candente

Fluid power introduction
Fluid power introductionFluid power introduction
Fluid power introduction
sukusobhaa
 
Compressor And Compressed Air Systems
Compressor And Compressed Air SystemsCompressor And Compressed Air Systems
Compressor And Compressed Air Systems
Saurabh Jain
 

La actualidad más candente (20)

Fundamental of hydraulic components
Fundamental of hydraulic componentsFundamental of hydraulic components
Fundamental of hydraulic components
 
Hydraulic and pneumatic
Hydraulic and pneumaticHydraulic and pneumatic
Hydraulic and pneumatic
 
Fluid power introduction
Fluid power introductionFluid power introduction
Fluid power introduction
 
Pneumatics mainpresentation
Pneumatics mainpresentationPneumatics mainpresentation
Pneumatics mainpresentation
 
Introduction to hydraulics and pneumatic by Varun Pratap Singh
Introduction to hydraulics and pneumatic by Varun Pratap SinghIntroduction to hydraulics and pneumatic by Varun Pratap Singh
Introduction to hydraulics and pneumatic by Varun Pratap Singh
 
Basic Pneumatics
Basic PneumaticsBasic Pneumatics
Basic Pneumatics
 
Applications of Pneumatic System with Machines
Applications of  Pneumatic System with MachinesApplications of  Pneumatic System with Machines
Applications of Pneumatic System with Machines
 
Pressure control valves
Pressure control valvesPressure control valves
Pressure control valves
 
pneumatic and hydraulic symbols
pneumatic and hydraulic symbolspneumatic and hydraulic symbols
pneumatic and hydraulic symbols
 
Hydraulic Power Pack and Hydraulic Symbols
Hydraulic Power Pack and Hydraulic SymbolsHydraulic Power Pack and Hydraulic Symbols
Hydraulic Power Pack and Hydraulic Symbols
 
Hydraulic Maintenance and Troubleshooting
Hydraulic Maintenance and TroubleshootingHydraulic Maintenance and Troubleshooting
Hydraulic Maintenance and Troubleshooting
 
Actuators in hydraulic system
Actuators in hydraulic systemActuators in hydraulic system
Actuators in hydraulic system
 
Hydraulics and pneumatics
Hydraulics and pneumaticsHydraulics and pneumatics
Hydraulics and pneumatics
 
Hydraulic Valves (Valves) (Pneumatics also)
Hydraulic Valves (Valves) (Pneumatics also)Hydraulic Valves (Valves) (Pneumatics also)
Hydraulic Valves (Valves) (Pneumatics also)
 
Compressor
CompressorCompressor
Compressor
 
Compressor And Compressed Air Systems
Compressor And Compressed Air SystemsCompressor And Compressed Air Systems
Compressor And Compressed Air Systems
 
Air Compressor
Air CompressorAir Compressor
Air Compressor
 
Hydraulic system
Hydraulic systemHydraulic system
Hydraulic system
 
Introduction to hydraulics and pneumatics
Introduction to hydraulics and pneumaticsIntroduction to hydraulics and pneumatics
Introduction to hydraulics and pneumatics
 
Hidraulic Symbols
Hidraulic Symbols Hidraulic Symbols
Hidraulic Symbols
 

Destacado

Pneumatics
PneumaticsPneumatics
Pneumatics
leotvrde
 
Pneumatics Powerpoint
Pneumatics PowerpointPneumatics Powerpoint
Pneumatics Powerpoint
guestf11186
 
UNIT 1: BASIC PNEUMATIC SYSTEM
UNIT 1: BASIC PNEUMATIC SYSTEMUNIT 1: BASIC PNEUMATIC SYSTEM
UNIT 1: BASIC PNEUMATIC SYSTEM
Zamanim Mamat
 
Babic components of hydraulic & pneumatic systems
Babic components of hydraulic & pneumatic systemsBabic components of hydraulic & pneumatic systems
Babic components of hydraulic & pneumatic systems
wakurets_21
 
Pneumatic system
Pneumatic systemPneumatic system
Pneumatic system
Amar Bhopi
 
Chapter 3 electro pneumatic.updated
Chapter 3 electro pneumatic.updatedChapter 3 electro pneumatic.updated
Chapter 3 electro pneumatic.updated
Hattori Sidek
 
Pneumatic1day
Pneumatic1dayPneumatic1day
Pneumatic1day
Legaspi66
 
Aviation Pneumatic Systems
 Aviation Pneumatic Systems  Aviation Pneumatic Systems
Aviation Pneumatic Systems
cloisios
 

Destacado (20)

Introduction to pneumatic
Introduction to pneumaticIntroduction to pneumatic
Introduction to pneumatic
 
Pneumatic system
Pneumatic systemPneumatic system
Pneumatic system
 
Pneumatics
PneumaticsPneumatics
Pneumatics
 
Pneumatics Powerpoint
Pneumatics PowerpointPneumatics Powerpoint
Pneumatics Powerpoint
 
UNIT 1: BASIC PNEUMATIC SYSTEM
UNIT 1: BASIC PNEUMATIC SYSTEMUNIT 1: BASIC PNEUMATIC SYSTEM
UNIT 1: BASIC PNEUMATIC SYSTEM
 
Babic components of hydraulic & pneumatic systems
Babic components of hydraulic & pneumatic systemsBabic components of hydraulic & pneumatic systems
Babic components of hydraulic & pneumatic systems
 
Pneumatic circuits
Pneumatic circuitsPneumatic circuits
Pneumatic circuits
 
Pneumatic system
Pneumatic systemPneumatic system
Pneumatic system
 
Lab pneumatic 2
Lab pneumatic 2Lab pneumatic 2
Lab pneumatic 2
 
PNEUMATIC
PNEUMATICPNEUMATIC
PNEUMATIC
 
Chapter 3 electro pneumatic.updated
Chapter 3 electro pneumatic.updatedChapter 3 electro pneumatic.updated
Chapter 3 electro pneumatic.updated
 
Basic hydraulic circuit
Basic hydraulic circuitBasic hydraulic circuit
Basic hydraulic circuit
 
Application of Trigonometry
Application of TrigonometryApplication of Trigonometry
Application of Trigonometry
 
Pneumatic1day
Pneumatic1dayPneumatic1day
Pneumatic1day
 
Pneumatic conveying system
Pneumatic conveying systemPneumatic conveying system
Pneumatic conveying system
 
Pneumatic Lab 3 JJ512
Pneumatic Lab 3 JJ512Pneumatic Lab 3 JJ512
Pneumatic Lab 3 JJ512
 
Chapter 1 introduction to pneumatic
Chapter 1 introduction to pneumaticChapter 1 introduction to pneumatic
Chapter 1 introduction to pneumatic
 
Pneumatic control
Pneumatic controlPneumatic control
Pneumatic control
 
Aviation Pneumatic Systems
 Aviation Pneumatic Systems  Aviation Pneumatic Systems
Aviation Pneumatic Systems
 
Introduction to mechatronics
Introduction to mechatronicsIntroduction to mechatronics
Introduction to mechatronics
 

Similar a Pneumatic System

PNEUMATIC AUTO FEED MULTI OPERATION MACHINE
PNEUMATIC AUTO FEED MULTI OPERATION MACHINEPNEUMATIC AUTO FEED MULTI OPERATION MACHINE
PNEUMATIC AUTO FEED MULTI OPERATION MACHINE
amarnath kenguva
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systems
thanhuce
 
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Ecway Technologies
 
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Ecwaytech
 
Fabrication of solar operated pneumatic reciprocating water pumping system
Fabrication of solar operated pneumatic reciprocating water pumping systemFabrication of solar operated pneumatic reciprocating water pumping system
Fabrication of solar operated pneumatic reciprocating water pumping system
Ecway Technologies
 

Similar a Pneumatic System (20)

Pneumatic Shearing and Bending Machine
Pneumatic Shearing and Bending MachinePneumatic Shearing and Bending Machine
Pneumatic Shearing and Bending Machine
 
Hydraulic and Pneumatic Drive System
Hydraulic and Pneumatic Drive SystemHydraulic and Pneumatic Drive System
Hydraulic and Pneumatic Drive System
 
Km143 three axis pneumatic modern trailer operating with lever (wecompress)
Km143 three axis pneumatic modern trailer operating with lever (wecompress)Km143 three axis pneumatic modern trailer operating with lever (wecompress)
Km143 three axis pneumatic modern trailer operating with lever (wecompress)
 
PNEUMATIC AUTO FEED MULTI OPERATION MACHINE
PNEUMATIC AUTO FEED MULTI OPERATION MACHINEPNEUMATIC AUTO FEED MULTI OPERATION MACHINE
PNEUMATIC AUTO FEED MULTI OPERATION MACHINE
 
Mini water service station
Mini water service stationMini water service station
Mini water service station
 
! Vehicles Hydraulic And Pneumatic Systems.ppt
! Vehicles Hydraulic And Pneumatic Systems.ppt! Vehicles Hydraulic And Pneumatic Systems.ppt
! Vehicles Hydraulic And Pneumatic Systems.ppt
 
DESIGN AND DEVELOPMENT OF PNEUMATIC STEERING CONTROL SYSTEM FOR AUTOMOTIVE VE...
DESIGN AND DEVELOPMENT OF PNEUMATIC STEERING CONTROL SYSTEM FOR AUTOMOTIVE VE...DESIGN AND DEVELOPMENT OF PNEUMATIC STEERING CONTROL SYSTEM FOR AUTOMOTIVE VE...
DESIGN AND DEVELOPMENT OF PNEUMATIC STEERING CONTROL SYSTEM FOR AUTOMOTIVE VE...
 
FABRICATION OF PNEUMATIC CONTROLLED RAMMER STRIKER FOR MOULDING PROCES.pptx
FABRICATION  OF  PNEUMATIC CONTROLLED RAMMER STRIKER FOR MOULDING PROCES.pptxFABRICATION  OF  PNEUMATIC CONTROLLED RAMMER STRIKER FOR MOULDING PROCES.pptx
FABRICATION OF PNEUMATIC CONTROLLED RAMMER STRIKER FOR MOULDING PROCES.pptx
 
1 converted
1 converted1 converted
1 converted
 
ME-6I-22655-UNIT-1-Shaikh-sir-Notes.pdf
ME-6I-22655-UNIT-1-Shaikh-sir-Notes.pdfME-6I-22655-UNIT-1-Shaikh-sir-Notes.pdf
ME-6I-22655-UNIT-1-Shaikh-sir-Notes.pdf
 
Safety Instrumentation and Emergency Shutdown Presentation Template Modules 3...
Safety Instrumentation and Emergency Shutdown Presentation Template Modules 3...Safety Instrumentation and Emergency Shutdown Presentation Template Modules 3...
Safety Instrumentation and Emergency Shutdown Presentation Template Modules 3...
 
Compressors and compressed air systems
Compressors and compressed air systemsCompressors and compressed air systems
Compressors and compressed air systems
 
Topic 3 - Working Principles.pptx
Topic 3 - Working Principles.pptxTopic 3 - Working Principles.pptx
Topic 3 - Working Principles.pptx
 
Automation 4.0
Automation 4.0Automation 4.0
Automation 4.0
 
components_of_hydraulic_and_pneumatic_system_-_part_1.pdf
components_of_hydraulic_and_pneumatic_system_-_part_1.pdfcomponents_of_hydraulic_and_pneumatic_system_-_part_1.pdf
components_of_hydraulic_and_pneumatic_system_-_part_1.pdf
 
HYDRAULICS AND PNEUMATICS (UNIT 4)
HYDRAULICS AND PNEUMATICS   (UNIT 4)HYDRAULICS AND PNEUMATICS   (UNIT 4)
HYDRAULICS AND PNEUMATICS (UNIT 4)
 
Compressed air system
Compressed air systemCompressed air system
Compressed air system
 
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
 
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...Et0077   fabrication of solar operated pneumatic reciprocating water pumping ...
Et0077 fabrication of solar operated pneumatic reciprocating water pumping ...
 
Fabrication of solar operated pneumatic reciprocating water pumping system
Fabrication of solar operated pneumatic reciprocating water pumping systemFabrication of solar operated pneumatic reciprocating water pumping system
Fabrication of solar operated pneumatic reciprocating water pumping system
 

Más de Vishal Singh (9)

Engineering System Modelling and Simulation Lab
Engineering System Modelling and Simulation LabEngineering System Modelling and Simulation Lab
Engineering System Modelling and Simulation Lab
 
NTPC Report
NTPC ReportNTPC Report
NTPC Report
 
Catia File
Catia FileCatia File
Catia File
 
Railway Training Report
Railway Training ReportRailway Training Report
Railway Training Report
 
Numerical analysis
Numerical analysisNumerical analysis
Numerical analysis
 
Physics nanophotonics
Physics nanophotonicsPhysics nanophotonics
Physics nanophotonics
 
Environmental project
Environmental projectEnvironmental project
Environmental project
 
Segway Robotics
Segway Robotics Segway Robotics
Segway Robotics
 
Motion Class 9
Motion Class 9 Motion Class 9
Motion Class 9
 

Último

DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
MayuraD1
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
AldoGarca30
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Kandungan 087776558899
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
Kamal Acharya
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 

Último (20)

DeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakesDeepFakes presentation : brief idea of DeepFakes
DeepFakes presentation : brief idea of DeepFakes
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
1_Introduction + EAM Vocabulary + how to navigate in EAM.pdf
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Computer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to ComputersComputer Lecture 01.pptxIntroduction to Computers
Computer Lecture 01.pptxIntroduction to Computers
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Design For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the startDesign For Accessibility: Getting it right from the start
Design For Accessibility: Getting it right from the start
 
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKARHAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
HAND TOOLS USED AT ELECTRONICS WORK PRESENTED BY KOUSTAV SARKAR
 
Thermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.pptThermal Engineering -unit - III & IV.ppt
Thermal Engineering -unit - III & IV.ppt
 
Unleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leapUnleashing the Power of the SORA AI lastest leap
Unleashing the Power of the SORA AI lastest leap
 
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak HamilCara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
Cara Menggugurkan Sperma Yang Masuk Rahim Biyar Tidak Hamil
 
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
Unit 4_Part 1 CSE2001 Exception Handling and Function Template and Class Temp...
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Online food ordering system project report.pdf
Online food ordering system project report.pdfOnline food ordering system project report.pdf
Online food ordering system project report.pdf
 
Hospital management system project report.pdf
Hospital management system project report.pdfHospital management system project report.pdf
Hospital management system project report.pdf
 
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
COST-EFFETIVE  and Energy Efficient BUILDINGS ptxCOST-EFFETIVE  and Energy Efficient BUILDINGS ptx
COST-EFFETIVE and Energy Efficient BUILDINGS ptx
 
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLEGEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
GEAR TRAIN- BASIC CONCEPTS AND WORKING PRINCIPLE
 
Block diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.pptBlock diagram reduction techniques in control systems.ppt
Block diagram reduction techniques in control systems.ppt
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
Moment Distribution Method For Btech Civil
Moment Distribution Method For Btech CivilMoment Distribution Method For Btech Civil
Moment Distribution Method For Btech Civil
 

Pneumatic System

  • 1. 362 SUBMITTED TO SUBMITTED BY DR. VINEET KUMAR VISHAL SINGH 00320903613 MAE 6TH SEMESTER IN-HOUSE TRAINING REPORT PNEUMATIC SYSTEM ETAT-362
  • 2. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | i Table of Contents Acknowledgement iii 1. Introduction 1 1.1 Comparison of Hydraulic and Pneumatic System 1.2 Advantages & Disadvantages of Pneumatic System 1.3 Applications 1.4 Components 2. Valves 9 2.1 Direction Control Valve 2.2 Methods of Actuation 2.3 Non-Return Valves 2.4 Flow Control Valves 2.5 Pressure Control Valves 3. Compressors 22 3.1 Piston 3.2 Double Acting 3.3 Multistage 3.4 Combined Two Stage 3.5 Diaphragm 3.6 Screw 3.7 Rotary 3.8 Lobe 3.9 Dynamic
  • 3. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | ii 4. Actuators 28 4.1 Single Acting 4.2 Double Acting 4.3 Cylinder End Cushions 4.4 Gear Motor 4.5 Vane Motor 4.6 Limited Rotation Actuators 4.7 Speed Control 5. Case Study 34 References 37
  • 4. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | iii Acknowledgement I take this opportunity to express our sincere gratitude to the people who have been helpful in the successful completion of our In-house training and this project. I would like to show my greatest appreciation to the highly esteemed and devoted technical staff, supervisors of our College. We are highly indebted to them for their tremendous support and help during the completion of our training and project. I am grateful to my teachers Dr. Vineet Kumar and Mr. Urfi Khan and who granted us the permission of in house training in the College. We would like to thanks to all those peoples who directly or indirectly helped and guided us to complete our training, including the instructors and technical officers of the Pneumatics Lab.
  • 5. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 1 Introduction
  • 6. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 2 Pneumatics may be defined as branch of engineering science which deals with the study of the behaviour and application of compressed air to power machine or control or regulate machines. It deals with generation, transmission and control of power using pressurized air. Gas in a pneumatic system behaves like a spring since it is compressible. Any gas can be used in pneumatic system but air is the most usual, for obvious reasons. Exceptions are most likely to occur on aircraft and space vehicles where an inert gas such as nitrogen is preferred or the gas is one which is generated on board. Actuation of the controls can be manual, Pneumatic or Electrical actuation. DIFFERENCES BETWEEN HYDRAULIC AND PNEUMATIC SYSTEMS One of the main differences between the two systems is that in pneumatics, air is compressible. In hydraulics, liquids are not. Other two distinct differences are given below. The pneumatic systems have two main features:  Pneumatic systems use compressed gas such as air or nitrogen to perform work processes.  Pneumatic systems are open systems, exhausting the compressed air to atmosphere after use. The hydraulic systems also have two main features:  Hydraulic systems use liquids such as oil and water to perform work processes.  Hydraulic systems are closed systems, recirculating the oil or water after use.
  • 7. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 3 Table 1.1 Comparison between Hydraulic and Pneumatic Systems S.NO. HYDRAULIC SYSTEM PNEUMATIC SYSTEM 1 It employs a pressurized liquid as fluid It employs a compressed gas usually air as a fluid 2 Oil hydraulics system operates at pressure upto 700 bar Pneumatic systems usually operate at 5 to 10 bar 3 Generally designed for closed systems Pneumatic systems are usually designed as open system 4 System get slowdown of leakage occurs Leakage does not affect the system much more 5 Valve operation are difficult Easy to operate the valves 6 Heavier in weight Light in weight 7 Pumps are used to provide pressurized liquids Compressors are used to provide compressed gas 8 System is unsafe to fire hazards System is free from fire hazards 9 Automatic lubrication is provided Special arrangements for lubrication needed.
  • 8. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 4 ADVANTAGES OF PNEUMATIC SYSTEM  Low inertia effect of pneumatic components due to low density of air.  Pneumatic Systems are light in weight.  Operating elements are cheaper and easy to operate  Power losses are less due to low viscosity of air  High output to weight ratio  Pneumatic systems offers a safe power source in explosive environment  Leakage is less and does not influence the systems. Moreover, leakage is not harmful DISADVANTAGES OF PNEUMATIC SYSTEMS  Suitable only for low pressure and hence low force applications  Compressed air actuators are economical up to 50 KN only  Generation of the compressed air is expensive compared to electricity  Exhaust air noise is unpleasant and silence has to be used  Rigidity of the system is poor  Weight to pressure ratio is large  Less precise. It is not possible to achieve uniform speed due to compressibility of air  Pneumatic systems is vulnerable to dirt and contamination
  • 9. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 5 APPLICATIONS Pneumatic systems are used in many applications. In construction, it is indispensable source of power for such tools as air drills, hammers, wrenches, and even air cushion supported structures, not to mention the many vehicles using air suspension , braking and pneumatic tires. In manufacturing, air is used to power high speed clamping, drilling, grinding, and assembly using pneumatic wrenches and riveting machines. Plant air is also used to power hoists and cushion support to transport loads through the plant. Many recent advances in air – cushion support are used in the military and commercial marine transport industry. Table 1.2 Applications of Pneumatic Systems MATERIAL HANDLING MANUFACTURING OTHER APPLICATIONS Clamping Shifting Positioning Orienting Feeding Ejection Braking Bonding Locking Packaging Feeding Sorting Stacking Drilling Turning Milling Sawing Finishing Forming Quality Control Stamping Embossing Filling Aircraft Cement Plants Chemical Plants Coal Mines Cotton Mills Diaries Forge Shops Machine Tools Door Control Turning Parts
  • 10. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 6 COMPONENTS Pneumatic system carries power by employing compressed gas generally air as a fluid for transmitting the energy from an energy-generating source to an energy – use point to accomplish useful work. Figure 1.1 Arrangement of Pneumatic System a) Air filters These are used to filter out the contaminants from the air. b) Compressor Compressed air is generated by using air compressors. Air compressors are either diesel or electrically operated. Based on the requirement of compressed air, suitable capacity compressors may be used.
  • 11. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 7 c) Air cooler During compression operation, air temperature increases. Therefore coolers are used to reduce the temperature of the compressed air. d) Dryer The water vapor or moisture in the air is separated from the air by using a dryer. e) Control Valves Control valves are used to regulate, control and monitor for control of direction flow, pressure etc. f) Air Actuator Air cylinders and motors are used to obtain the required movements of mechanical elements of pneumatic system. g) Electric Motor Transforms electrical energy into mechanical energy. It is used to drive the compressor h) Receiver tank The compressed air coming from the compressor is stored in the air receiver. FUNCTIONS OF COMPONENTS  Pneumatic actuator converts the fluid power into mechanical power to do useful work.  Compressor is used to compress the fresh air drawn from the atmosphere.  Storage reservoir is used to store a given volume of compressed air.  Valves are used to control the direction, flow rate and pressure of compressed air.
  • 12. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 8  External power supply (Motor) is used to drive the compressor.  Piping system carries the pressurized air from one location to another. Air is drawn from the atmosphere through air filter and raised to required pressure by an air compressor. As the pressure rises, the temperature also rises and hence air cooler is provided to cool the air with some preliminary treatment to remove the moisture. Then the treatment pressurized air needs to get stored to maintain the pressure. With the storage reservoir, a pressure switch is fitted to start and stop the electric motor when pressure falls and reached the required level, respectively. The cylinder movement is controlled by pneumatic valve. One side of the pneumatic valve is connected to the compressed air and silencers for the exhaust air and the other side of the valve is connected to port A and Port B of the cylinder.
  • 13. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 9 Valves
  • 14. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 10 Valve are defined as devices to control or regulate the commencement, termination and direction and also the pressure or rate of flow of a fluid under pressure which is delivered by a compressor or vacuum pump or is stored in a vessel. FUNCTION  They control the supply of air to power units, example cylinders  They provide signal which govern the sequence of operation  They act as interlock and safety devices Valves used in pneumatics mainly have a control function that is when they act on some process, operation or quantity to be stopped. A control function requires control energy, it being desirable to achieve the greatest possible effect with the least effort. The form of control energy will be dictated by the valve’s mode of actuation and may be manual, mechanical, electrical hydraulic or pneumatic. Figure 2.1 Simple Valve TYPES 1. Direction control valve 2. Non return valves 3. Flow control valves 4. Pressure control valves
  • 15. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 11 DIRECTION CONTROL VALVES In order to control the movement of air actuators, compressed air has to be regulated, controlled and reversed with a predetermined sequence. Pressure and flow rates of the compressed air has to be controlled to obtain the desired level of force and speed of air actuators. The function of directional control valve is to control the direction of flow in the pneumatic circuit. DCVs are used to start, stop and regulate the direction of air flow and to help in the distribution of air in the required line. TYPES 1. Based on construction  Poppet or seat valves  Ball seat valve  Disc seat valve  Diaphragm Valves  Sliding spool valves  Longitudinal slide valve  Suspended spool valves  Rotary spool valves o Two way valves o Three way valves o Four way valves 2. Based on methods of Actuation  Mechanical  Electrical  Pneumatic
  • 16. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 12 3. Based on Size of the port Size refers to a valve’s port size. The port sizes are designated as M5, G1/8, and G1/4 etc. M refer to Metric thread, G refer to British standard pipe (BSP) thread. 4. Based on mounting styles  Sub base  Manifold  In-line  Valve island Table 2.1 Port Marking PORT OLD (LETTER) SYSTEM ISO (NUMBER) SYSTEM REMARKS Pressure Port P 1 Supply Port Working Port A 2 3/2 DCV Working Ports A,B 4,2 4/2 or 5/2 DCV Exhaust Port R 3 3/2 DCV Exhaust Ports R,S 5,3 5/2 DCV Pilot Ports Z or Y 12 Pilot Line (Flow 1-2) Pilot Ports Z 14 Pilot Line (Flow 1-4) Pilot Ports Z or Y 10 Pilot Line (No Flow) Internal Pilot Ports Pz, Py 81,91 Auxiliary Pilot Line
  • 17. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 13 PORT AND POSITION 2/2 directional Valve Ports Position 3/2 Directional Control Valve (Normally Closed) 3/2 Directional Control Valve (Normally Open ) 4/2 Direction Control Valve 5/2 Direction Control Valve 5/3 Direction Control Valve Table 2.2 Ports in different positions
  • 18. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 14 POPPET DIRECTION CONTROL VALVES A. Ball seat valve In a poppet valve, discs, cones or balls are used to control flow. In a simple 2/2 normally closed valve. If the push button is pressed, ball will lift off from its seat and allows the air to flow from port P to port B. When the push button is released, spring force and air pressure keeps the ball back and closes air flow from port P to port B. B. Disc seat poppet valve In a disc type 3/2 way DCV, When push button is released, ports 1 and 3 are connected via hollow pushbutton stem. If the push button is pressed, port 3 is first blocked by the moving valve stem and then valve disc is pushed down so as to open the valve thus connecting port 1 and 3. When the push button is released, spring and air pressure from port 1 closes the valve. Figure 2.2 Ball Seat Valve Figure 2.3 Disc Seat Poppet Valve
  • 19. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 15 C. Diaphragm valves The diaphragm between the actuator and valve body hermetically isolates the fluid from the actuator. Closed position: When de-energized, the valve is closed by spring action Open position: If the actuator is pressurized by the control pressure, it simultaneously lifts the control piston and the valve spindle to open the valve. The valves are maintenance-free and extremely robust and can be retrofitted with a comprehensive range of accessories, e.g. electrical position feedback, stroke limitation or manual override. Advantages of poppet valves  Response of poppet valve is very fast- short stroke to provide maximum flow opening  They give larger opening (larger flow) of valves for a small stroke  The valve seats are usually simple elastic seals so wear is minimum  They are insensitive to dust and dirt and they are robust, seats are self-cleaning  Maintenance is easy and economical.  They are inexpensive Figure 2.4 Diaphragm Valve
  • 20. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 16  They give longer service life: short stroke and few wearing parts give minimum wear and maximum life capabilities Disadvantages of poppet valves  The actuating force is relatively high, as it is necessary to overcome the force of the built in reset spring and the air pressure.  They are noisy if flow fluctuation is large. SPOOL DIRECTION CONTROL VALVES A. Pneumatically actuated 3/2 DCV In normal position, the working port (2) is closed to the pressure port (1) and open to the exhaust port (3). When the compressed air is applied through the pilot port (12), the spool is moved against the spring. In the actuated position, the working port (2) is open to the pressure port (1) and closed to the exhaust port (3). Thus, the application of the compressed air to the port 12 causes the pressure port (1) to be connected to the working port (2). Figure 2.5 Pneumatically Actuated 3/2 DCV
  • 21. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 17 B. Pneumatically actuated 4/2 DCV In a 4/2 way valve pneumatically operated DCV, Switch over is effected by direct application of pressure. If compressed air is applied to pilot spool through control port 12, it connects port 1 with 2 and 4 is exhausted through port 3. If the pilot pressure is applied to port 14, then 1 is connected with 4 and line 2 exhausted through port 3. On disconnecting the compressed air from the control line, the pilot spool remains in its current position until spool receives a signal from the other control side. C. Suspended Disc Direction Control Valves This valve is quite similar to 4/2 way spool valve. In this design disc is used instead of a spool. This suspended disc can be moved by pilot pressure or by solenoid or by mechanical means. In this design, main disc connects port 1 to either port 4 or 2. The secondary seat discs seal the exhaust port 3 whichever is not functional. These values are generally provided with manual override to manually move the cylinder. Figure 2.6 Pneumatically Actuated 4/2 DCV Figure 2.7 Suspended Disc DCV
  • 22. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 18 D. Rotary valves The rotary spool directional control valve has a round core with one or more passages or recesses in it. The core is mounted within a stationary sleeve. As the core is rotated within the stationary sleeve, the passages or recesses connect or block the ports in the sleeve. The ports in the sleeve are connected to the appropriate lines of the fluid system. By rotating the handle, core gets connected to different holes to give the required configuration of the valve. This type of the valve can be directly mounted on panel using bolt. METHODS OF ACTUATION The methods of actuation of pneumatic directional control valves depend upon the requirements of the task. The types of actuation vary;  Manually actuated  Mechanically actuated  Pneumatically actuated  Electrically actuated  Combined actuation Figure 2.8 Rotary Valve
  • 23. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 19 Table 2.3 Different types of Actuation Method TYPE OF ACTUATION TYPE OF CONTROL SYMBOL Manual General Push button Distant lever operated Foot pedal Mechanical Spring return Spring centred Roller Operated Idle Roller Pneumatic Direct Indirect, Pilot Operated Electrical Single Solenoid Double Solenoid Combined Double Solenoid with pilot operated
  • 24. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 20 NON RETURN VALVES Non return valves permit flow of air in one direction only, the other direction through the valve being at all times blocked to the air flow. Mostly the valves are designed so that the check is additionally loaded by the downstream air pressure, thus supporting the non-return action. TYPES  Check valve  Shuttle valve  Restrictor check valve  Quick exhaust valve  Two pressure valve FLOW CONTROL VALVES A flow control valve regulates the rate of air flow. The control action is limited to the air flow passing through the valve when it is open, maintaining a set volume per unit of time. Figure 2.9 Non-Return Valves Figure 2.10 Flow Control Valves
  • 25. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 21 PRESSURE CONTROL VALVE Compared with hydraulic systems, few pressure control valves are brought into use in pneumatics. Pressure control valves control the pressure of the air flowing through the valve or confined in the system controlled by the valve. There are three types of pressure control valves 1. Pressure limiting valve 2. Pressure sequence valve 3. Pressure regulator or pressure reducing valve Figure 2.11 Pressure Control Valves
  • 26. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 22 Compressors
  • 27. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 23 It is a mechanical device which converts mechanical energy into fluid energy. The compressor increases the air pressure by reducing its volume which also increases the temperature of the compressed air. The compressor is selected based on the pressure it needs to operate and the delivery volume. The compressor can be classified into two main types a. Positive displacement compressors b. Dynamic displacement compressor Positive displacement compressors include piston type, vane type, diaphragm type and screw type. PISTON COMPRESSORS Piston compressors are commonly used in pneumatic systems. It produces one pulse of air per piston stroke. As the piston moves down during the inlet stroke the inlet valve opens and air is drawn into the cylinder. As the piston moves up the inlet valve closes and the exhaust valve opens which allows the air to be expelled. The valves are spring loaded. The single cylinder compressor gives significant amount of pressure pulses at the outlet port. The pressure developed is about 3-40 bar. Figure 3.1 Piston Compressor
  • 28. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 24 DOUBLE ACTING COMPRESSOR The pulsation of air can be reduced by using double acting compressor. It has two sets of valves and a crosshead. As the piston moves, the air is compressed on one side whilst on the other side of the piston, the air is sucked in. Due to the reciprocating action of the piston, the air is compressed and delivered twice in one piston stroke. Pressure higher than 30bar can be produced MULTISTAGE COMPRESSOR As the pressure of the air increases, its temperature rises. It is essential to reduce the air temperature to avoid damage of compressor and other mechanical elements. The multistage compressor with intercooler in-between. It is used to reduce the temperature of compressed air during the compression stages. The inter-cooling reduces the volume of air which used to increase due to heat. The compressed air from the first stage enters the intercooler where it is cooled. This air is given as input to the second stage where it is compressed again. The multistage compressor can develop a pressure of around 50bar. Figure 3.2 Double Acting Compressor Figure 3.3 Multistage Compressor
  • 29. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 25 COMBINED TWO STAGE COMPRESSORS In this type, two-stage compression is carried out by using the same piston. Initially when the piston moves down, air is sucked in through the inlet valve. During the compression process, the air moves out of the exhaust valve into the intercooler. As the piston moves further the stepped head provided on the piston moves into the cavity thus causing the compression of air. Then, this is let out by the exhaust port. DIAPHRAGM COMPRESSOR In piston compressors the lubricating oil from the pistons walls may contaminate the compressed air. The contamination is undesirable in food, pharmaceutical and chemical industries. For such applications diaphragm type compressor can be used. The piston reciprocates by a motor driven crankshaft. As the piston moves down it pulls the hydraulic fluid down causing the diaphragm to move along and the air is sucked in. When the piston moves up the fluid pushes the diaphragm up causing the ejection of air from the outlet port. Since the flexible diaphragm is placed in between the piston and the air no contamination takes place. Figure 3.4 Combined Two Stage Compressor Figure 3.5 Diaphragm Compressor
  • 30. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 26 SCREW COMPRESSOR Piston compressors are used when high pressures and relatively low volume of air is needed. The system is complex as it has many moving parts. For medium flow and pressure applications, screw compressor can be used. It is simple in construction with less number of moving parts. The air delivered is steady with no pressure pulsation. It has two meshing screws. The air from the inlet is trapped between the meshing screws and is compressed. The contact between the two meshing surface is minimum, hence no cooling is required. These systems are quite in operation compared to piston type. The screws are synchronized by using external timing gears. ROTARY VANE COMPRESSORS The principle of operation of vane compressor is similar to the hydraulic vane pump. The unbalanced vane compressor consists of spring loaded vanes seating in the slots of the rotor. The pumping action occurs due to movement of the vanes along a cam ring. The rotor is eccentric to the cam ring. As the rotor rotates, the vanes follow the inner surface of the cam ring. The space between the vanes decreases near the outlet due to the eccentricity. This causes compression of the air. These compressors are free from pulsation. If the eccentricity is zero no flow takes place. Figure 3.6 Screw Compressor Figure 3.7 Rotary Vane Compressor
  • 31. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 27 LOBE COMPRESSOR The lobe compressor is used when high delivery volume but low pressure is needed. It consists of two lobes with one being driven and the other driving. It is similar to the Lobe pump used in hydraulic systems. The operating pressure is limited by leakage between rotors and housing. As the wear increases during the operation, the efficiency falls rapidly. DYNAMIC COMPRESSORS When very large volume of compressed air is required in applications such as ventilators, combustion system and pneumatic powder blower conveyors, the dynamic compressor can be used. The pressure needed is very low in such applications. The impeller rotates at a high speed. Large volume of low pressure air can be provided by blowers. The blowers draw the air in and the impeller flings it out due to centrifugal force. Positive displacement compressors need oil to lubricate the moving parts, whereas the dynamic compressors have no such need. The efficiency of these compressors is better than that of reciprocating types. Figure 3.8 Lobe Compressor Figure 3.9 Dynamic Compressor
  • 32. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 28 Actuators
  • 33. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 29 Actuators are output devices which convert energy from pressurized hydraulic oil or compressed air into the required type of action or motion. In general, hydraulic or pneumatic systems are used for gripping and/or moving operations in industry. These operations are carried out by using actuators. Actuators can be classified into three types. 1. Linear actuators: These devices convert hydraulic/pneumatic energy into linear motion. 2. Rotary actuators: These devices convert hydraulic/pneumatic energy into rotary motion. 3. Actuators to operate flow control valves: these are used to control the flow and pressure of fluids such as gases, steam or liquid. The construction of hydraulic and pneumatic linear actuators is similar. However they differ at their operating pressure ranges. Typical pressure of hydraulic cylinders is about 100 bar and of pneumatic system is around 10 bar. SINGLE ACTING CYLINDER These cylinders produce work in one direction of motion hence they are named as single acting cylinders. The compressed air pushes the piston located in the cylindrical barrel causing the desired motion. The return stroke takes place by the action of a spring. Generally the spring is provided on the rod side of the cylinder. Figure 4.1 Single Acting Cylinder
  • 34. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 30 DOUBLE ACTING CYLINDER The main parts of a hydraulic double acting cylinder are: piston, piston rod, cylinder tube, and end caps. The piston rod is connected to piston head and the other end extends out of the cylinder. The piston divides the cylinder into two chambers namely the rod end side and piston end side. The seals prevent the leakage of oil between these two chambers. The cylindrical tube is fitted with end caps. The pressurized oil, air enters the cylinder chamber through the ports provided. In the rod end cover plate, a wiper seal is provided to prevent the leakage of oil and entry of the contaminants into the cylinder. The combination of wiper seal, bearing and sealing ring is called as cartridge assembly. The end caps may be attached to the tube by threaded connection, welded connection or tie rod connection. The piston seal prevents metal to metal contact and wear of piston head and the tube. These seals are replaceable. End cushioning is also provided to prevent the impact with end caps. CYLINDER END CUSHIONS Double acting cylinders generally contain cylinder cushions at the end of the cylinder to slow down the movement of the piston near the end of the stroke. Cushioning arrangement avoids the damage due to the impact occurred when a fast moving piston is stopped by the end caps. Deceleration of the piston starts when the tapered plunger enters the opening in the cap and closes the main fluid exit. This restricts the exhaust flow from the barrel to the port. This throttling causes the initial speed reduction. During the last portion of the stroke the oil has to exhaust through an adjustable opening since main fluid exit closes. Thus the remaining fluid exists Figure 4.2 Double Acting Cylinder
  • 35. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 31 through the cushioning valve. Amount of cushioning can be adjusted by means of cushion screw. A check valve is provided to achieve fast break away from the end position during retraction motion. A bleed screw is built into the check valve to remove the air bubbles present in a hydraulic type system. GEAR MOTOR: A ROTARY ACTUATOR It consists of two inter meshing gears inside a housing with one gear attached to the drive shaft. The air enters from the inlet, causes the rotation of the meshing gear due to difference in the pressure and produces the torque. The air exists from the exhaust port. Gear motors tend to leak at low speed, hence are generally used for medium speed applications. VANE MOTOR: A ROTARY ACTUATOR A rotary vane motor consists of a rotor with sliding vanes in the slots provided on the rotor. The rotor is placed eccentrically with the housing. Air enters from the inlet port, rotates the rotor and thus torque is produced. Air is then released from the exhaust port (outlet). Figure 4.3 Cylinder End Cushions Figure 4.4 Gear Motor Figure 4.5 Vane Motor
  • 36. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 32 LIMITED ROTATION ACTUATORS It consists of a single rotating vane connected to output shaft. It is used for double acting operation and has a maximum angle of rotation of about 270°. These are generally used to actuate dampers in robotics and material handling applications. Other type of limited rotation actuator is a rack and pinion type actuator. SPEED CONTROL For an actuator, the operational speed is determined by the fluid flow rate and the cylinder actuator area or the motor displacement. The speed can only be controlled by adjusting the fluid flow to the actuator, because the physical dimension of the actuator is fixed. Since the air is compressible, flow control is difficult as compared to the hydraulic system. There are various ways of controlling the fluid flow. Figure 4.6 Limited Rotation Actuator Figure 4.7 Speed Control Arrangement
  • 37. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 33 One of the method is that a pump having fixed displacement is kept along an actuator. Thus, the fluid goes either to the pump or the actuator. When the direction control valve moves from its centre position the actuator of area ‘A’, the piston moves with a velocity. v = 𝑉/𝐴 If the pump delivery volume ‘V’ can be adjusted by altering swash plate angle of a piston pump or by using a variable displacement vane pump, no further speed control will be needed.
  • 38. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 34 Case Study
  • 39. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 35 To design a pneumatic circuit to accomplish a simple operation where a double- acting cylinder is used to transfer parts from a magazine. The cylinder is to be advanced either by operating a push button or by a foot pedal. Once the cylinder is fully advanced, it is to be retracted to its initial position. A 3/2-way roller lever valve is to be used to detect the full extension of the cylinder. COMPONENTS USED The pneumatic components which can be used to implement the mentioned task are as follows:  Double acting cylinder  3/2 push button valve  3/2 roller valve  Shuttle valve  3/2 foot pedal actuated valve  5/3 pneumatic actuated direction control valve  Compressed air source and connecting piping Figure 5.1 Magazine Ejection Setup
  • 40. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 36 WORKING According to the problem stated, upon actuation of either the push button of valve (S1) or the foot pedal valve (S2), a signal is generated at 1 or 1(3) side of the shuttle valve. The OR condition is met and the signal is passed to the control port 14 of the direction control valve (V2). Due to this signal, the left position of V2 is actuated and the flow of air starts. Pressure is applied on the piston side of the cylinder (A) and the cylinder extends. If the push button or pedal valve is released, the signal at the direction control valve (V2) port is reset. Since DCV (V2) is a double pilot valve, it has a memory function which doesn’t allow switching of positions. As the piston reaches the rod end position, the roller valve (S3) is actuated and a signal is applied to port 12 of the DCV (V2). This causes actuation of right side of DCV (V2). Due to this actuation, the flow enters at the rod-end side of the cylinder, which pushes the piston towards left and thus the cylinder retracts. Figure 5.2 Magazine Ejection Mechanism
  • 41. V i s h a l S i n g h ( 0 0 3 2 0 9 0 3 6 1 3 ) | 37 References  Boltan, W., Mechatronics: electronic control systems in mechanical and electrical engineering, Longman, Singapore, 1999  Boucher, T. O., Computer automation in manufacturing - an Introduction, Chapman and Hall, 1996  Blackburn,J. F.,G.Reethof, and J. L. Shearer, Fluid Power Control, New York: Technology Press of M. I. T. and Wiley  Hasebrink J.P., and Kobler R., “Fundamentals of Pneumatics/electropeumatics”, FESTO Didactic publication No. 7301, Esslingen Germany, 1979.