SlideShare a Scribd company logo
Enviar búsqueda
Cargar
Iniciar sesión
Registrarse
FAST VP Step by Step Module 1
Denunciar
Yunchao (Kevin) Wang
Seguir
25 de Apr de 2015
•
0 recomendaciones
•
1,394 vistas
FAST VP Step by Step Module 1
25 de Apr de 2015
•
0 recomendaciones
•
1,394 vistas
Yunchao (Kevin) Wang
Seguir
Denunciar
FAST VP Step by Step Module 1
1 de 41
Descargar ahora
1
de
41
Recomendados
FAST VP Step by Step Module 2
Yunchao (Kevin) Wang
1.2K vistas
•
47 diapositivas
FAST VP Deep Dive
Yunchao (Kevin) Wang
2.3K vistas
•
60 diapositivas
How fast works in symmetrix vmax
Srinivas Gollanapalli
2.6K vistas
•
39 diapositivas
Presentation vmax hardware deep dive
solarisyougood
5.5K vistas
•
50 diapositivas
EMC Vmax3 tech-deck deep dive
solarisyougood
17.7K vistas
•
155 diapositivas
Compare emc symmetrix vmax cat presentation
xKinAnx
2.1K vistas
•
43 diapositivas
Más contenido relacionado
La actualidad más candente
Time finder
Juby Manoj
4K vistas
•
71 diapositivas
Symm configuration management
.Gastón. .Bx.
5K vistas
•
109 diapositivas
102550121 symmetrix-foundations-student-resource-guide
Amit Sharma
6.7K vistas
•
50 diapositivas
EMCSymmetrix vmax-10
solarisyougood
979 vistas
•
54 diapositivas
EMC VNX
Gokser GUL
8.9K vistas
•
39 diapositivas
SCSI-3 PGR Support on Symm
Yunchao (Kevin) Wang
1.5K vistas
•
46 diapositivas
La actualidad más candente
(20)
Time finder
Juby Manoj
•
4K vistas
Symm configuration management
.Gastón. .Bx.
•
5K vistas
102550121 symmetrix-foundations-student-resource-guide
Amit Sharma
•
6.7K vistas
EMCSymmetrix vmax-10
solarisyougood
•
979 vistas
EMC VNX
Gokser GUL
•
8.9K vistas
SCSI-3 PGR Support on Symm
Yunchao (Kevin) Wang
•
1.5K vistas
EMC FAST VP for Unified Storage Systems
EMC
•
1K vistas
VNX Overview
bluechipper
•
14.4K vistas
Storage Area Networking: SAN Technology Update & Best Practice Deep Dive for ...
EMC
•
5.3K vistas
EMC Atmos for service providers
solarisyougood
•
1.2K vistas
Emc isilon technical deep dive workshop
solarisyougood
•
2.2K vistas
EMC Vnx master-presentation
solarisyougood
•
3.4K vistas
Emc recoverpoint technical
solarisyougood
•
3K vistas
Vmax architecture
Edgar Garcia
•
3.6K vistas
Emc vmax3 technical deep workshop
solarisyougood
•
3.9K vistas
Ibm power ha v7 technical deep dive workshop
solarisyougood
•
5.8K vistas
Vnx series-technical-review-110616214632-phpapp02
Newlink
•
1.3K vistas
Emc
Sachin Tyagi
•
369 vistas
Emc data domain technical deep dive workshop
solarisyougood
•
3K vistas
Emc vnx2 technical deep dive workshop
solarisyougood
•
11.6K vistas
Similar a FAST VP Step by Step Module 1
EMC VNX FAST VP
EMC
7.6K vistas
•
25 diapositivas
Pro sphere customer technical
solarisyougood
266 vistas
•
49 diapositivas
Transforming Mission Critical Applications
Cenk Ersoy
1.1K vistas
•
43 diapositivas
Presentation integration vmware with emc storage
solarisyourep
538 vistas
•
30 diapositivas
VMAX : répondez aux niveaux de services applicatifs les plus élevés
RSD
377 vistas
•
27 diapositivas
CENTERA_MIGRATOR_PPT_NOTES
Daniel Moshief
321 vistas
•
32 diapositivas
Similar a FAST VP Step by Step Module 1
(20)
EMC VNX FAST VP
EMC
•
7.6K vistas
Pro sphere customer technical
solarisyougood
•
266 vistas
Transforming Mission Critical Applications
Cenk Ersoy
•
1.1K vistas
Presentation integration vmware with emc storage
solarisyourep
•
538 vistas
VMAX : répondez aux niveaux de services applicatifs les plus élevés
RSD
•
377 vistas
CENTERA_MIGRATOR_PPT_NOTES
Daniel Moshief
•
321 vistas
Performance & agilité les atouts du datacenter électronique selon XtremIO
RSD
•
507 vistas
Ficha Tecnica EMC VNX5400
RaGaZoMe
•
1.1K vistas
Emc isilon overview
solarisyougood
•
3.1K vistas
Le Software Defined Solutions, ou comment automatiser les ressources IT ?
RSD
•
345 vistas
Using Unisphere for VMAX to Manage CKD Devices in zOS
Barry Snoots
•
520 vistas
Emc vplex deep dive
solarisyougood
•
4.5K vistas
Emc vspex customer_presentation_euc_citrix_xen_desktop5.6_2.0
xKinAnx
•
353 vistas
Dedicated Networks For IP Storage
EMC
•
718 vistas
Cloud Models, Considerations, & Adoption Techniques
EMC
•
1.5K vistas
Presentation cloud services
xKinAnx
•
675 vistas
Emc storag
Mahamudul Hassan
•
572 vistas
INDUSTRY-LEADING TECHNOLOGY FOR LONG TERM RETENTION OF BACKUPS IN THE CLOUD
EMC
•
2.3K vistas
Manage transactional and data mart loads with superior performance and high a...
Principled Technologies
•
140 vistas
Emc vspex customer_presentation_private_cloud_virtualized_share_point
xKinAnx
•
331 vistas
FAST VP Step by Step Module 1
1.
Welcome to FAST
VP – Step by Step. Copyright © 2012 EMC Corporation. All rights reserved Welcome to FAST VP – Step by Step. Copyright © 1996, 2000, 2001, 2002, 2003, 2004, 2005, 2006, 2007, 2008, 2009, 2010, 2011, 2012 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. THE INFORMATION IN THIS PUBLICATION IS PROVIDED “AS IS.” EMC CORPORATION MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THE INFORMATION IN THIS PUBLICATION, AND SPECIFICALLY DISCLAIMS IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC2, EMC, Data Domain, RSA, EMC Centera, EMC ControlCenter, EMC LifeLine, EMC OnCourse, EMC Proven, EMC Snap, EMC SourceOne, EMC Storage Administrator, Acartus, Access Logix, AdvantEdge, AlphaStor, ApplicationXtender, ArchiveXtender, Atmos, Authentica, Authentic Problems, Automated Resource Manager, AutoStart, AutoSwap, AVALONidm, Avamar, Captiva, Catalog Solution, C-Clip, Celerra, Celerra Replicator, Centera, CenterStage, CentraStar, ClaimPack, ClaimsEditor, CLARiiON, ClientPak, Codebook Correlation Technology, Common Information Model, Configuration Intelligence, Configuresoft, Connectrix, CopyCross, CopyPoint, Dantz, DatabaseXtender, Direct Matrix Architecture, DiskXtender, DiskXtender 2000, Document Sciences, Documentum, elnput, E-Lab, EmailXaminer, EmailXtender, Enginuity, eRoom, Event Explorer, FarPoint, FirstPass, FLARE, FormWare, Geosynchrony, Global File Virtualization, Graphic Visualization, Greenplum, HighRoad, HomeBase, InfoMover, Infoscape, Infra, InputAccel, InputAccel Express, Invista, Ionix, ISIS, Max Retriever, MediaStor, MirrorView, Navisphere, NetWorker, nLayers, OnAlert, OpenScale, PixTools, Powerlink, PowerPath, PowerSnap, QuickScan, Rainfinity, RepliCare, RepliStor, ResourcePak, Retrospect, RSA, the RSA logo, SafeLine, SAN Advisor, SAN Copy, SAN Manager, Smarts, SnapImage, SnapSure, SnapView, SRDF, StorageScope, SupportMate, SymmAPI, SymmEnabler, Symmetrix, Symmetrix DMX, Symmetrix VMAX, TimeFinder, UltraFlex, UltraPoint, UltraScale, Unisphere, VMAX, Vblock, Viewlets, Virtual Matrix, Virtual Matrix Architecture, Virtual Provisioning, VisualSAN, VisualSRM, Voyence, VPLEX, VSAM-Assist, WebXtender, xPression, xPresso, YottaYotta, the EMC logo, and where information lives, are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. © Copyright 2012 EMC Corporation. All rights reserved. Published in the China. 1Module 1: FAST VP HOWTO
2.
Copyright © 2012
EMC Corporation. All rights reserved 2Module 1: FAST VP HOWTO
3.
Upon completion of
this class, you should be able to: Copyright © 2012 EMC Corporation. All rights reserved Upon completion of this class, you should be able to: •Provide an overview of FAST and FAST VP •Explain FAST VP elements and terminology •Describe the algorithms used by FAST VP •Explain the use of time windows and other Symmetrix parameters to manage FAST VP •Describe interoperability of FAST VP with other Enginuity software 3Module 1: FAST VP HOWTO
4.
Upon completion of
this lesson, you should be able to: Copyright © 2012 EMC Corporation. All rights reserved Upon completion of this lesson, you should be able to: •Provide an overview of FAST and FAST VP •List the benefits of FAST and FAST VP 4Module 1: FAST VP HOWTO
5.
FAST moves application
data at the volume (LUN) level. Entire devices are promoted or demoted Copyright © 2012 EMC Corporation. All rights reserved FAST moves application data at the volume (LUN) level. Entire devices are promoted or demoted between tiers based on overall device performance. FAST VP adds finer granularities of performance measurement and data movement. The data from a single Thin Device under FAST control can be spread across multiple tiers. Based on performance data gathered at the extent level, the FAST controller is free to re-locate individual sub-extents of a Thin Device. 5Module 1: FAST VP HOWTO
6.
The chart on
the left is a Device Activity Report that shows a small number of active devices that Copyright © 2012 EMC Corporation. All rights reserved The chart on the left is a Device Activity Report that shows a small number of active devices that are candidates for Flash drives and a large number of inactive devices that are candidates for SATA drives. Moving the active data to Flash can improve application performance by two-to-eight times, while moving inactive data to SATA can free up Fibre Channel capacity for other applications and reduce the cost of storage. A key point here is that a 1 TB SATA drive costs 80 percent less per megabyte than a 146 GB Fibre Channel drive. 6Module 1: FAST VP HOWTO
7.
FAST is most
effective in an environment where the workload tends to be skewed and the skew Copyright © 2012 EMC Corporation. All rights reserved FAST is most effective in an environment where the workload tends to be skewed and the skew patterns are dynamic. For example, if devices that are heavily accessed this month may be under-utilized next month, a suitable FAST policy will continually perform the necessary re-locations to locate the heavily used devices on faster performing drives. FAST is not beneficial if the workload is not skewed or if the I/O workload is static, since workload skews can then be addressed using manual methods such as Symmetrix VLUN Migration. 7Module 1: FAST VP HOWTO
8.
FAST and FAST
VP automate and optimize storage tiers allowing better utilization of EFDs for Copyright © 2012 EMC Corporation. All rights reserved FAST and FAST VP automate and optimize storage tiers allowing better utilization of EFDs for data in need of high performance and SATA technology for infrequently accessed data. Combining EFD, Fibre Channel, and low-cost SATA drives provides improved performance in a tiered storage solution at a lower operating cost than a similarly sized Fibre Channel only array. FAST and FAST VP use defined policies to non-disruptively relocate Symmetrix devices to the most beneficial drive technology based upon I/O profile. FAST VP can relocate smaller chunks of data located on Thin Devices from one tier of storage to another. FAST supports both FBA and CKD devices. FAST VP supports FBA devices only. FAST and FAST VP can be managed via the Symmetrix Management Console or SYMCLI. 8Module 1: FAST VP HOWTO
9.
FAST not only
improves performance by leveraging Flash drives, it also enables efficient use of Copyright © 2012 EMC Corporation. All rights reserved FAST not only improves performance by leveraging Flash drives, it also enables efficient use of SATA drives to reduce storage costs. Here, we see a comparison of a 100 TB configuration of all Fibre Channel compared to a combination of Flash, Fibre Channel, and SATA. This is an example of a 100 TB configuration, which is close to the average capacity configured in a Symmetrix VMAX. Configuring SATA helps offset the cost of the Flash drives (on a drive basis, a 1 TB SATA drive costs 80 percent less per megabyte than a 146 GB Fibre Channel), reducing total storage system acquisition costs by 20 percent. FAST reduces management overhead (assuming one FTE [full-time equivalent] without FAST and one-half FTE with FAST)) to lower operational costs by 43 percent. This also includes power, cooling, and maintenance. Combining both leads to a 27 percent lower, three-year total cost of ownership. 9Module 1: FAST VP HOWTO
10.
The benefits of
FAST are: Copyright © 2012 EMC Corporation. All rights reserved The benefits of FAST are: • The automated movement of hot devices to higher performing drives and less used drives to lower performing drives in a dynamically changing application environment. • Achieves better cost / benefit ratios by improving application performance at the same cost, or providing the same application performance at lower cost. Cost factors include the price of drives, their energy usage and the effort to manage them. • Management and operation of FAST is provided by Symmetrix Management Console (SMC), as well as the Solutions Enabler Command Line Interface (SYMCLI). EMC Ionix ControlCenter® StorageScope™ and Symmetrix Performance Analyzer can provide visibility into the use of storage types in FAST environments and the resulting impact on performance. With Symmetrix Performance Analyzer, storage administrators can quickly view key performance indicators such as IOPs and the response time of a storage group before and after the execution of a FAST change plan to assess the impact on performance. 10Module 1: FAST VP HOWTO
11.
Upon completion of
this lesson, you should be able to: Copyright © 2012 EMC Corporation. All rights reserved Upon completion of this lesson, you should be able to: •Explain FAST VP elements and terminology •Describe the algorithms used by FAST VP •Explain the use of time windows and other Symmetrix parameters to manage FAST VP 11Module 1: FAST VP HOWTO
12.
FAST VP adds
finer granularities of performance measurement and data movement. As Copyright © 2012 EMC Corporation. All rights reserved FAST VP adds finer granularities of performance measurement and data movement. As performance data is gathered at the sub-LUN level and extents are moved based on activity, the data from a single Thin Device under FAST VP control can be spread across multiple tiers. FAST VP can put less-frequently accessed data on more cost-effective drives and only the most busy extents on higher performing drives. This allows the most active 20% of data to be placed on EFD for greater performance while the 80% of less active data can be placed on Fibre Channel and SATA drives at a lower cost. 12Module 1: FAST VP HOWTO
13.
There are three
main elements related to the use of FAST. These are: Copyright © 2012 EMC Corporation. All rights reserved There are three main elements related to the use of FAST. These are: • Symmetrix Tier — A shared resource with common technologies. • FAST Policy — A policy that manages data placement and movement across Symmetrix tiers to achieve service levels and for one or more storage groups. • Storage Group — A logical grouping of devices for common management. 13Module 1: FAST VP HOWTO
14.
For FAST VP,
the storage tier is called a VP tier. When defined, VP tiers contain between one and Copyright © 2012 EMC Corporation. All rights reserved For FAST VP, the storage tier is called a VP tier. When defined, VP tiers contain between one and four thin storage pools. Each Thin Pool must contain Data Devices of the same RAID protection type, and be configured on the same drive technology. In the case of Fibre Channel and SATA drives, the rotational speed of the drives must also match. However, Thin Pools containing Data Devices configured on rotating drives of different sizes and speeds may be combined in a single VP tier. The maximum number of tiers that can be defined on a Symmetrix array is 256. If creating a new tier exceeds this limit, then an existing tier must be deleted before creating the new tier. Symmetrix tier names cannot exceed 32 characters. Each tier name must be unique. Only alphanumeric characters, hyphens ( - ), and underscores ( _ ) are allowed, however, the name cannot start with a hyphen or an underscore. Tier names are case insensitive, in other words, TierA and tiera are not unique names. 14Module 1: FAST VP HOWTO
15.
The first tier
that is added to a given policy, determines the type of tier that policy will contain. Copyright © 2012 EMC Corporation. All rights reserved The first tier that is added to a given policy, determines the type of tier that policy will contain. For policies that include VP tiers, the upper capacity usage limit for each storage tier is specified as a percentage of the configured, logical capacity of the associated storage group. FAST VP supports the association of up to 1,000 storage groups with FAST policies containing thin storage tiers. The usage limit for each tier must be between 1 percent and 100 percent. When combined, the upper usage limit for all thin storage tiers in the policy must total at least 100 percent, but may be greater than 100 percent. Creating a policy with a total upper usage limit greater than 100 percent allows flexibility with the configuration of a storage group. Here, data may be moved between tiers without necessarily having to move a corresponding amount of other data within the same storage group. Multiple FAST policies may re-use the same tier, allowing different usage limits to be applied to different storage groups for the same tier. A Symmetrix VMAX storage array will support up to 256 FAST policies. Each FAST policy name may be up to 32 alpha-numeric characters, hyphens (-), and underscores (_). Policy names are not case-sensitive. 15Module 1: FAST VP HOWTO
16.
A storage group
is a logical collection of Symmetrix devices that are managed together. Storage Copyright © 2012 EMC Corporation. All rights reserved A storage group is a logical collection of Symmetrix devices that are managed together. Storage group definitions are shared between FAST and Auto-provisioning Groups. However, a Symmetrix device may only belong to one storage group that is under FAST control. Storage groups are associated with a FAST policy that defines the maximum percentage of devices in the storage group that can exist in a particular tier. FAST and FAST VP support the movement of certain device types within the Symmetrix. A storage group created for the purposes of FAST or FAST VP may not contain the following device types: Thin (TDEV), VDEV, DLDEV, CKD, AS400, ICOS, Metadevice members, SAVEDEV, Data Devices (TDATs), DRV, SFS and Vault. A Symmetrix VMAX storage array will support up to 8192 storage groups associated with FAST policies. Storage groups may contain up to 4096 devices. 16Module 1: FAST VP HOWTO
17.
A policy associates
a storage group with up to three tiers. When aggregated, the percentage of Copyright © 2012 EMC Corporation. All rights reserved A policy associates a storage group with up to three tiers. When aggregated, the percentage of storage specified for each tier in the policy must total at least 100 percent. The same FAST policy may be applied to multiple storage groups; however, a storage group may only be associated with one policy. When a storage group is associated with a FAST policy, a priority value must be assigned to the storage group. This priority value can be between 1 and 3, with 1 being the highest priority—the default is 2. When multiple storage groups share the same policy, the priority value is used when the devices contained in the storage groups are competing for the same resources in one of the associated tiers. Storage groups with a higher priority will be given preference when deciding which devices need to be re-located to another tier. 17Module 1: FAST VP HOWTO
18.
Assume that a
policy is configured with three tiers and that the three tiers have a maximum Copyright © 2012 EMC Corporation. All rights reserved Assume that a policy is configured with three tiers and that the three tiers have a maximum allocation of i%, j% and k% respectively. When the sum of the tier allocations (i% + j% +k%) is 100%, there can be no flexibility of storage allocations between the different storage groups. It also provides an easy algorithm for chargeback. A 300% sum of all Tier Allocations means that at any given time each associated storage group can be entirely on any tier. FAST VP will place the allocations completely based on performance criteria. In this case, all storage of the tiers is shared dynamically by all storage groups associated with any FAST policy. Since users will mostly be concerned with usage of premium tiers, the greatest practical flexibility will be achieved by configuring the least performing tier with a Tier Allocation of 100% and limit the Tier Allocation of the premium tiers. As their needs change over time, this will enable sharing of the limited, expensive storage by multiple applications. 18Module 1: FAST VP HOWTO
19.
The example shows
two production and one development storage groups. The two production Copyright © 2012 EMC Corporation. All rights reserved The example shows two production and one development storage groups. The two production storage groups have a tier allocation that aggregates to 100%. This means the the percentage of storage associated with each tier is fixed for these storage groups. In contrast to the production application storage groups, the development storage group can be moved around more easily, since up to 100% of the storage group can be located on the SATA pool if the I/O activity is low. Later, when I/O demand picks up, the more active allocation extents can be moved to the FC pool. 19Module 1: FAST VP HOWTO
20.
Initial Analysis Period: Copyright
© 2012 EMC Corporation. All rights reserved Initial Analysis Period: The Initial Analysis Period defines the minimum amount of time a Thin Device should be under FAST VP management before any performance related data movements should be applied. This period only accounts for time passed while the performance time window is open. The initial analysis period can be configured to be between 2 hours and 4 weeks, however, it cannot exceed that of the workload analysis period. The default is 8 hours. Workload Analysis Period: The Workload Analysis Period determines the degree to which FAST VP metrics are influenced by recent host activity, and also less recent host activity, that takes place while the performance time window is considered open. The longer the time defined in the workload analysis period, the greater the amount of weight assigned to less recent host activity. The workload analysis period can be configured to be between 2 hours and 4 weeks. The default is 1 week (7 days). These FAST VP performance metrics provide a measure of activity that assigns greater weight to more recent I/O requests, but are also influenced by less recent activity. By default, based on a Workload Analysis Period of 24 hours, an I/O that has just been received is weighted two times more heavily than an I/O received 24 hours previously. 20Module 1: FAST VP HOWTO
21.
The performance time
windows are used to identify the business cycle for the Symmetrix array. Copyright © 2012 EMC Corporation. All rights reserved The performance time windows are used to identify the business cycle for the Symmetrix array. They specify date and time ranges (past or future) when samples will be included in, or excluded from, the FAST performance data analysis. The intent of defining performance time windows, is to distinguish periods of time when the Symmetrix is idle from periods when the Symmetrix is active, and to only collect performance data during the active periods. Performance windows are common for Optimizer, FAST, and FAST VP. A default performance time window collects all performance data samples, 24 hours a day, 7 days a week, 365 days a year. 21Module 1: FAST VP HOWTO
22.
Device movement time
windows are used to specify date and time ranges when moves are Copyright © 2012 EMC Corporation. All rights reserved Device movement time windows are used to specify date and time ranges when moves are allowed, or not allowed, to be performed. In order to prevent FAST VP from changing the current tiering allocation of a Thin Device, a feature called device pinning may be used. Pinning a device will lock all current extent allocations for the device in their current locations, and will prevent FAST VP from relocating them. Any new allocations performed for a pinned device, will come from the Thin Pool the device is bound to. These allocations will also not be moved by FAST VP. 22Module 1: FAST VP HOWTO
23.
In the example
below – An exclusive performance window has been added to exclude performance data collections for a specific weekend. We will covert the specifics of setting up Copyright © 2012 EMC Corporation. All rights reserved In the example below – An exclusive performance window has been added to exclude performance data collections for a specific weekend. We will covert the specifics of setting up time windows in the next module. sun200 /VMAXe symtw list -sid 95 -type perf Symmetrix ID: 000195900495 Performance Time Windows Sunday : 00:00 - 24:00 Monday : 00:00 - 24:00 Tuesday : 00:00 - 24:00 Wednesday : 00:00 - 24:00 Thursday : 00:00 - 24:00 Friday : 00:00 - 24:00 Saturday : 00:00 - 24:00 Exclusive Time Windows (1) { Fri Dec 02 22:00:00 2011 - Mon Dec 05 06:00:00 2011 } 23Module 1: FAST VP HOWTO
24.
The Data Movement
Mode for FAST VP can be either Off (no movement) or Automatic. Copyright © 2012 EMC Corporation. All rights reserved The Data Movement Mode for FAST VP can be either Off (no movement) or Automatic. The Pool Reserved Capacity (PRC) reserves a percentage of each pool included in a VP tier for non-FAST VP activities. The purpose of this, is to ensure that FAST VP data movements do not fill a Thin Pool, and subsequently cause a new extent allocation, a result of a host write, to fail. When the percentage of unallocated space in a Thin Pool is equal to the PRC, FAST VP will no longer perform data movements into that pool. However, data movements may continue to occur out of the pool to other pools. When the percentage of unallocated space becomes greater than the PRC, FAST VP can begin performing data movements into that pool again. The PRC can be set on a per pool basis or system-wide. The PRC can be configured to be between 1% and 80%. The default is 10%. The Relocation Rate is a quality of service (QoS) setting for FAST VP and affects the aggressiveness of data movement requests generated by FAST VP. This aggressiveness is measured as the amount of data that will be requested to be moved at any given time, and the priority given to moving the data between pools. The relocation rate can be configured to be between 1 and 10, with 1 being the most aggressive. The default is 5. 24Module 1: FAST VP HOWTO
25.
The SYMCLI listing
of the FAST control parameters highlights those parameters that are shared Copyright © 2012 EMC Corporation. All rights reserved The SYMCLI listing of the FAST control parameters highlights those parameters that are shared between FAST DP, FAST VP, and optimizer as well as those that are unique to FAST DP and FAST VP. Note that only the FAST VP control parameters are relevant for VMAXe arrays. On VMAXe arrays all the FAST DP parameters show a value of N/A. 25Module 1: FAST VP HOWTO
26.
The FAST &
FAST VP control parameters can be set via SMC as well. This is where we check FAST Copyright © 2012 EMC Corporation. All rights reserved The FAST & FAST VP control parameters can be set via SMC as well. This is where we check FAST and Optimizer control parameters. The first half of the screen refers to parameters that are shared between FAST, FAST VP, and Optimizer. The second half contains parameters that are specific to FAST VP. Please note that on VMAXe Arrays, SMC will only show the settings relevant FAST VP. VMAXe arrays only support virtual provisioning. 26Module 1: FAST VP HOWTO
27.
There are two
components of FAST VP – Symmetrix microcode and the FAST controller. Copyright © 2012 EMC Corporation. All rights reserved There are two components of FAST VP – Symmetrix microcode and the FAST controller. The Symmetrix microcode is a part of the Enginuity storage operating environment that controls components within the array. The FAST controller is a service that runs on the service processor. When FAST VP is active, both components participate in the execution of two algorithms – the intelligent tiering algorithm and the allocation compliance algorithm – to determine appropriate data placement. The intelligent tiering algorithm uses performance data collected by the microcode, as well as supporting calculations performed by the FAST controller, to issue data movement requests to the VLUN VP data movement engine. The allocation compliance algorithm enforces the upper limits of storage capacity that can be used in each tier by a given storage group by also issuing data movement requests to the VLUN VP data movement engine. Data movements performed by the microcode are achieved by moving allocated extents between tiers. The size of data movement can be as small as 768 KB, representing a single allocated Thin Device extent, but will more typically be an entire extent group, which is 7,680 KB in size. 27Module 1: FAST VP HOWTO
28.
The read miss
metric accounts for each DA read operation that is performed. Reads to areas of a Copyright © 2012 EMC Corporation. All rights reserved The read miss metric accounts for each DA read operation that is performed. Reads to areas of a Thin Device that have not had space allocated in a Thin Pool are not counted. Also, read hits, which are serviced from cache, are not considered. Write operations are counted in terms of the number of distinct DA operations that are performed. The metric accounts for when a write is de-staged – write hits to cache are not considered. Writes related to specific RAID protection schemes will also not be counted. In the case of RAID 1 protected devices, the write I/O is only counted for one of the mirrors. In the case of RAID 5 and RAID 6 protected devices, parity writes are not counted. Pre-fetch operations are accounted for in terms of the number of distinct DA operations performed to pre-fetch data spanning a FAST VP extent. This metric considers each DA read operation performed as a pre-fetch operation. Workload related to internal copy operations, such as drive rebuilds, clone operations, VLUN migrations, or even FAST VP data movements, is not included in the FAST VP metrics. The intelligent tiering algorithm considers the performance metrics of all Thin Devices under FAST VP control, and determines the appropriate tier for each extent group. The allocation compliance algorithm is used to enforce the per-tier storage capacity usage limits. 28Module 1: FAST VP HOWTO
29.
The intelligent tiering
algorithm is structured into two components; a main component that Copyright © 2012 EMC Corporation. All rights reserved The intelligent tiering algorithm is structured into two components; a main component that executes within Symmetrix microcode and a secondary, supporting, component that executes within the FAST controller on the service processor. The main component assesses whether extent groups need to be moved in order to optimize the use of the FAST VP storage tiers. If so, the required data movement requests are issued to the VLUN VP data movement engine. When determining the appropriate tier for each extent group, the main component makes use of both the FAST VP metrics, previously discussed, and supporting calculations performed by the secondary component on the service processor. The intelligent tiering algorithm runs during open data movement windows, when FAST is enabled and the FAST VP operating mode is Automatic. 29Module 1: FAST VP HOWTO
30.
The goal of
the allocation compliance algorithm is to detect and correct situations where the Copyright © 2012 EMC Corporation. All rights reserved The goal of the allocation compliance algorithm is to detect and correct situations where the allocated capacity for a particular storage group within a thin storage tier exceeds the maximum capacity allowed by the associated FAST policy. A storage group is considered to be in compliance with its associated FAST policy when the configured capacity of the Thin Devices in the storage group is located on tiers defined in the policy and when the usage of each tier is within the upper limits of the tier usage limits specified in the policy. When a compliance violation exists, the algorithm will generate a data movement request to return the allocations within the required limits. This request will explicitly indicate which Thin Device extents should be moved, and the specific Thin Pools they should be moved to. The size of the data movement request depends on the amount of capacity that is currently out of compliance, but also on the user-defined relocation rate. The maximum size of request that can be generated is 10 GB worth of data movements. When the relocation rate is set to anything other than 1, the FAST controller divides 10 GB by the relocation rate to determine the new maximum. For example, if the relocation rate is set to 2, the maximum request size will be 5 GB; if it is 10, the maximum size will be 1 GB. The compliance algorithm runs every 10 minutes during open data movement windows, when FAST is enabled and the FAST VP operating mode is Automatic. 30Module 1: FAST VP HOWTO
31.
Data movements executed
by FAST VP are performed by the VLUN VP data movement engine, Copyright © 2012 EMC Corporation. All rights reserved Data movements executed by FAST VP are performed by the VLUN VP data movement engine, and involve moving Thin Device extents between Thin Pools within the array. Extents are moved via a move process only; extents are not swapped between pools. The movement of extents, or extent groups, does not change the Thin Device binding information. That is, the Thin Device will still remain bound to the pool it was originally bound to. New allocations for the Thin device, as the result of host writes, will continue to come from the bound pool. Only extents that are allocated will be moved. No back-end configuration changes are performed during a FAST VP data movement, and no configuration locks are held during the process. As swaps are not performed, there is no requirement for any swap space, such as DRVs, to facilitate data movement. In order to prevent FAST VP from changing the current tiering allocation of a Thin Device, a feature called device pinning may be used. Pinning a device will lock all current extent allocations for the device in their current locations, and will prevent FAST VP from relocating them. 31Module 1: FAST VP HOWTO
32.
Upon completion of
this lesson, you should be able to: Copyright © 2012 EMC Corporation. All rights reserved Upon completion of this lesson, you should be able to: •Compare FAST (DP) and FAST VP •Discuss FAST Controller states and activities •Describe interoperability of FAST and FAST VP with other Enginuity software 32Module 1: FAST VP HOWTO
33.
FAST moves application
data at the volume (LUN) level. Entire devices are promoted or demoted Copyright © 2012 EMC Corporation. All rights reserved FAST moves application data at the volume (LUN) level. Entire devices are promoted or demoted between tiers based on overall device performance. FAST VP adds finer granularities of performance measurement and data movement. The data from a single Thin Device under FAST control can be spread across multiple tiers. The FAST controller is free to relocate individual sub-extents of a Thin Device, based on performance data gathered at the extent level. Note: Only FAST VP is relevant for VMAXe arrays. 33Module 1: FAST VP HOWTO
34.
There are five
possible states that the FAST controller can be reported in. These are: Copyright © 2012 EMC Corporation. All rights reserved There are five possible states that the FAST controller can be reported in. These are: 1. Enabled — The FAST controller will perform all of its functions: performance data collection, performance data analysis, configuration change plan generation, and configuration change plan execution. 2. Disabled — The FAST controller will only perform one of its functions: performance data collection. Data analysis and configuration change plan generation or execution will not be performed. 3. Disabling — The FAST controller is transitioning from Enabled to Disabled. 4. DisabledwithError — The FAST controller has stopped operation due to an internal error. None of the FAST Controller operations will be performed. 5. Degraded — The FAST controller can perform some or all of its functions. However, it cannot perform each function fully. For more details on each of the states consult the FAST VP Technical note. 34Module 1: FAST VP HOWTO
35.
When the state
of the FAST controller is queried, and the state is Enabled, the current activity Copyright © 2012 EMC Corporation. All rights reserved When the state of the FAST controller is queried, and the state is Enabled, the current activity being performed by the controller will also be displayed. Valid activities include: • Idle — The FAST controller is currently idle. • FetchingStats — The FAST controller is collecting Symmetrix device performance statistics. • AnalyzingStats — The FAST controller is performing analysis on the collected device performance statistics. • PendingPlan — A configuration change plan has been approved and its execution scheduled. • RunningPlan — A configuration change plan is currently being executed. 35Module 1: FAST VP HOWTO
36.
FAST and FAST
VP operates alongside Symmetrix features such as Symmetrix Optimizer, Dynamic Copyright © 2012 EMC Corporation. All rights reserved FAST and FAST VP operates alongside Symmetrix features such as Symmetrix Optimizer, Dynamic Cache Partitioning, and Auto-provisioning groups. While both FAST and Symmetrix Optimizer can be operated independently of each other on a Symmetrix VMAX array, they do share several configuration settings between them. Refer to the page entitled: “Control Parameters related to FAST and FAST VP” to identify the shared and unique parameters. 36Module 1: FAST VP HOWTO
37.
FAST and FAST
VP are fully interoperable with all Symmetrix replication technologies—SRDF, Copyright © 2012 EMC Corporation. All rights reserved FAST and FAST VP are fully interoperable with all Symmetrix replication technologies—SRDF, TimeFinder/Clone, TimeFinder/Snap, and Open Replicator. Any active replication on a Symmetrix device remains intact while the device is being moved or swapped. Similarly, all incremental relationships are maintained for the moved or swapped devices. However, what must be kept in mind, is that FAST device movements will consume array resources. This means that planning must be performed in determining when FAST device movements should occur to minimize impact on other replication processes. Remember, that all relocations performed by FAST DP occur on standard devices. All relocations performed by FAST VP occur on Thin Device extents. The source device of the TimeFinder/Clone session, or Clone emulation session, can be moved or swapped by FAST and FAST VP. A device that is the target device of a TimeFinder/Clone session, or a Clone emulation session, can also be moved or swapped by FAST or FAST VP, provided that the target has been split or activated. The source device in a TimeFinder/Snap session can be moved or swapped by FAST or FAST VP. The control device in an Open Replicator session, push or pull, can be moved or swapped by FAST or FAST VP. 37Module 1: FAST VP HOWTO
38.
An RDF1 volume,
with local protection, can be moved or swapped by FAST while also actively Copyright © 2012 EMC Corporation. All rights reserved An RDF1 volume, with local protection, can be moved or swapped by FAST while also actively replicating to an RDF2 volume, in either synchronous or asynchronous mode. Similarly, an RDF2 volume can be moved or swapped while being replicated to by an RDF1 volume. Thin SRDF devices, R1 or R2, can be associated with a FAST policy. Extents of SRDF devices can be moved between tiers while the devices are being actively replicated, in either synchronous or asynchronous mode. While there are no restrictions on the ability to move or swap SRDF devices with FAST and FAST VP, device movements are restricted to the array upon which the FAST Controller is operating. If an RDF1 device is moved between two tiers, FAST or FAST VP will not automatically perform a corresponding move of the respective RDF2 device on a remote array. This means that, in a SRDF failover scenario, the remote Symmetrix array will have different performance characteristics than the failed local production array. Based on FAST DP movements, while it is possible to move R2 devices manually on the R1 side, it is not possible to move Thin Device extents away from the pool that the Thin Device is bound to using VLUN migration. So, it is not possible to replicate the changes made to the R1 side on the R2 side when Thin Pools are being managed by FAST VP. 38Module 1: FAST VP HOWTO
39.
Storage groups created
for the purposes of FAST or FAST VP may also be used for Auto- Copyright © 2012 EMC Corporation. All rights reserved Storage groups created for the purposes of FAST or FAST VP may also be used for Auto- provisioning, and the other way round. However, while a device may be contained in multiple storage groups for the purposes of Auto-provisioning, it may only be contained in one storage group that is associated with a FAST or FAST VP policy. While Auto-provisioning storage groups can share devices, FAST or FAST VP managed storage groups cannot share devices. As a result of this, it may not be possible to use already configured storage groups for the purposes of FAST or FAST VP. 39Module 1: FAST VP HOWTO
40.
Key points covered
in this class: Copyright © 2012 EMC Corporation. All rights reserved Key points covered in this class: •Overview of FAST and FAST VP •FAST and FAST VP elements and terminology •Algorithms used by FAST and FAST VP •Time windows and other Symmetrix parameters to manage FAST and FAST VP •Interoperability of FAST and FAST VP with other Enginuity software 40Module 1: FAST VP HOWTO
41.
Please feel free
to contact me if you have any questions. Copyright © 2012 EMC Corporation. All rights reserved Please feel free to contact me if you have any questions. Kevin Wang (kevin.y.wang@emc.com) 41Module 1: FAST VP HOWTO