Inspection Information
Required Checked Items
http://www.investmentpropertiesmiamiflorida.com/checklist.html
Interior
1. Address mandatory on property.
2. Doors must be weather tight.
3. No double cylinder dead bolt locks allowed.
4. No exposed wiring.
5. All light fixtures must be covered (light globe).
6. Reverse cycle A/C with heat or permanently installed
space heater.
7. Smoke alarms required (Bedrooms & Kitchen).
8. No missing spacers on electrical panel box.
10. 4/25/2014
10
Inspection Information
Required Checked Items
http://www.investmentpropertiesmiamiflorida.com/checklist.html
Interior
9. Water Heater must be vented to exterior with water
relief line.
10. No deteriorated carpeting or tiles.
11. Window operators must be working.
12. Window screens are required.
13. Bedrooms minimum size is 8 x 10.
14. Bedroom must have a privacy door (you cannot go
through one bedroom to get to another).
There must be a window 10% of the room size leading
to exterior
12. 4/25/2014
12
Inspection Information
Required Items to Be Checked
http://www.investmentpropertiesmiamiflorida.com/checklist.html
Interior
14. Continued
There must be a closet in order for the room to be
qualified as a bedroom.
15. Kitchen - a range hood is needed over the stove, if
there is no window in the kitchen.
16. Bathroom must have a window or a ventilator fan.
17. There must no plumbing leaks.
18. The utilities must be on for the inspection.
19. All appliances must be in good working condition.
14. 4/25/2014
14
Inspection Information
Required Checked Items
http://www.investmentpropertiesmiamiflorida.com/checklist.html
Exterior
1. No deteriorated vent screens or outside crawl cover
spaces.
2. If there are window bars in the bedrooms, they must
have breakaways minimum size of 20” x 41”.
3. No scaling paint in the interior or exterior of the
property.
4. No junk or trash, no junk vehicles or appliances in
yard. (The yard and surrounding areas must be kept
clean and must not have overgrown vegetation.
16. 4/25/2014
16
Inspection Information
Required Checked Items
http://www.investmentpropertiesmiamiflorida.com/checklist.html
Exterior
5. Zoning issues – electric meter and water meter
assigned to the dwelling must meet applicable
zoning requirements. There must be no other
zoning violations as indicated by the inspector. (No
multi-family use in a single family zone.)
6. No water seepage from windows, ceilings, walls, and
no leaking roof.
7. No deteriorated roof overhang.
17. 4/25/2014
17
Most Common Reasons Why
Units Fail Section 8 Inspections
http://www.investmentpropertiesmiamiflorida.com/checklist.html
1. Smoke alarms missing or not working.
2. Lack of ventilation in bathroom.
3. Outlet covers missing or broken.
4. Infestation by bugs or vermin.
5. Absence of handrails where 4 or more
consecutive steps.
6. Utilities disconnected (must be connected).
19. 4/25/2014
19
Most Common Reasons Why
Units Fail Section 8 Inspections
http://www.investmentpropertiesmiamiflorida.com/checklist.html
7. Hazards (i.e. tripping as a result of floor covering or
exposed electrical wiring.
8. One window in each room must open and have a
screen.
9. Chipping paint on the outside of the building –
gutters, outside surfaces of building.
10. Hazardous hole or trash in the yard.
11. Door not sealed properly (light can be seen coming
through).
12. No hot or cold running water.
20. 4/25/2014
20
What is occurring in this picture to
cause a Section 8 Inspection Failure?
http://www.investmentpropertiesmiamiflorida.com/checklist.html
21. 4/25/2014
21
Most Common Reasons Why
Units Fail Section 8 Inspections
http://www.investmentpropertiesmiamiflorida.com/checklist.html
13. All windows must have sash cords or balancers and
must stay in the open position without assistance.
14. All ceilings must be at least 7 feet in height in areas
used for living, sleeping, etc….
15. All steps to landing or basements have handrails.
16. Baths without windows must have power fan or
gravity vents in high rise buildings.
17. Open electrical distribution box must be covered with
appropriate cover.
23. 4/25/2014
23
Common Reasons Units Fail
Section 8 Inspections
http://www.investmentpropertiesmiamiflorida.com/checklist.html
18. Windows in bedroom too small and will not
qualify as areas for sleeping.
19. Security bars can’t be opened from the
interior will not be allowed to remain.
24. 4/25/2014
24
Section 8 Approval Summary
List Your Unit
Find qualified tenant.
Complete the Request for Tenancy Approval (RTA)
forms.
Schedule Unit Inspection using Housing Quality
Standards HQS Checklist
Both parties sign lease and submit to Section 8
office for approval.
Collect Security Deposit.
Upon lease approval, wait for first rent check!!!
Make sure Utilities are in tenant’s name before giving
keys.