This document presents Sonkor International's DD Monobloc heat pump product line. The heat pumps are single chassis units designed for mobile homes, cottages, cabins, and temporary offices. They provide cooling and heating with an operating range of -4°F to 125.6°F. Key features include simple installation requiring only two holes, ultra-quiet operation, and certifications for safety and energy efficiency. Models include high wall and low wall units in various sizes with electric heating options.
FULL ENJOY Call Girls In Mahipalpur Delhi Contact Us 8377877756
Double Duct Heat Pumps 2012
1. Sonkor International
Sales Presentation: DD Monobloc (1)
High Efficiency Single Chassis “Monobloc” Heat Pump
A unique solution
Provides cooling and heating for :
Mobile Homes/Cottages/Cabins
Residential Containers/Pre Fabrication Units
Portable/Temporary Offices
Ambient-Operating range between
- 4F (-20°C) to + 125.6F (+ 52°C)
1
2. Sonkor International
Sales Presentation: DD Monobloc (1)
Application Product Solution
Mobile/Pre Fabricated Units Product Range Superior to Window and Splits
The special lightweight construction The full range of Sonkor heat pumps Our cylinder block heat pump was
of mobile homes and residential adapts well to extreme conditions uniquely designed for this type of
prefabs provide good insulation in from the bitter cold of northern application and offers many
winter but not in summer. Unit countries to dry or damp heat advantages over window, package
placement is sometimes unclear locations such as in Africa, Asia, or traditional split systems, including
until the actual time of sale, which India, USA, Latin America. ease of installation and unique
could mean a variety of temperature performance .
and humidity ranges.
2
3. Sonkor International Applications
Sales Presentation: DD Monobloc (1)
Mobile Homes/Cabins Container Housing Temporary Offices
Cottages/Cabins/Pre Fabs Day and Night: Simple Comfort Strong Thermal Loads
Special attention was devoted to the Used on job sites or even small office These applications have high thermal
acoustic insulation of heat pumps buildings - in either case you will need loads especially in summer conditions.
allowing the units to be installed in any powerful machines to meet the ever- Adding to the external loads are items
room configuration: living room, bedroom, changing thermal loads. Our product such as computers, lamps and heat
guest rooms, etc. range provides a solution for these needs generated from people. Thanks to the
with the utmost respect of environmental special fresh air intake feature our heat
and acoustic comfort. pumps ensures optimum comfort whilst
also providing a high level of air quality
and low concentrations of C02.
3
4. Sonkor International No Outdoor Unit Required
Sales Presentation: DD Monobloc (1)
Products and Solutions
High wall - iCool and iWarm Product Range
There are four product configurations including an EC motor option de-
signed to improve energy efficiency and increase the COP and EER of the
units. An additional option is the possibility to add 1600 watts of back up
heat. The unit will work up to minus 4 degrees Fahrenheit (minus 20 de-
grees Centigrade). Our sleek design measures only 7.7 inches (19.5 centi-
meters) in depth and includes activated carbon filters.
Low wall - PTTW Product Range
The low wall product range also consists of four models configured with AC
or EC motors. One of the versions is equipped with 2000 watts of back up
heat, which allows for continuous operation of the unit up to - 4F (-20°C).
Hot gas bypass, on board controls, and an indoor air exchange system are
just a few of the many features. Extremely compact measuring only 9.45
inches (24 centimeters) in depth. This is a very attractive design with many
options.
4
5. Sonkor International Benefits
Sales Presentation: DD Monobloc (1)
Simplified Installation Ultra Quiet Ecological
Two Tubes Ultra Quiet Ecology and low energy
consumption
Installation is easy requiring only two Our use of Expanded Polypropylene The use of high efficiency motors and
holes on the outside wall. (EPP) and insulating fibers provide levels compressors help obtain the minimum
of soundproofing impossible with COP and EER levels to comply with the
In installations where outside tempera- traditional window or package type units. European Energy labeling Directive 2013
tures reach below 32°F (0°C), we recom- and 2014 and in North America the DOE/
mend the installer connect the condensate The units offer a comfortable low noise AHRI standards 210/240-2008 (Window
outlet for heat pump operation. level at the top of it’s class. units) 310/380-2004 (PTAC) .
Additionally, the possibililty of theft or
tampering is greatly reduced since the unit
is located 100% on the inside of the
building.
5
6. Sonkor International Benefits
Sales Presentation: DD Monobloc (1)
Low Wall Mount High Wall Mount CO2 Minimized
Low Wall Range High Wall Range Fresh Air Exchange
Our floor range is aesthetic to the eye and For those preferring a high wall unit our The presence of fresh air exchange in
competes quite favorably against tradition- unique design appears to be as a tradi- both product platforms guarantees a con-
al compact fan coils. tional split unit but has all the advantage stant fresh air intake rate of 30-40 m3/h.
of being self contained on the inside of the This is particularly useful in bedrooms or
Attractive in design with on board controls. building. The lower flap and adjustable au- offices, where the CO2 levels tend to in-
to louver are designed to distribute opti- crease with the presence of people. This
mally the air in the surrounding environ- is a plus not found in traditional split type
ment. units.
6
7. Sonkor International Additional Benefits
Sales Presentation: DD Monobloc (1)
-4F (–20°C) Outdoor +125.6F (+52°C) Outdoor On Board Controls
Low and High Wall Units T3 - Tropicalized Performance Practicality
Air-to-air heat pumps, such as split, Our rigorous testing helps ensure smooth In addition to offering remote controls the
window, and package units have problems operation and minimal reduction in units have on board controls for ease of
of not providing the necessary thermal performance of the units even in extreme use. Both low and high wall units come
power when the outside temperature tropical conditions: with infrared hand held remote con-
drops below 32 degrees F (0 degrees C). trols.
90F (32°C) indoor temperature
Our range ensures maximum comfort
even in these extreme conditions, 125.6F (52°C) outdoor temperature
reducing the dependency of defrost
cycling through the use of a hot gas This is made possible through the
bypass system. generous heat exchangers and air flow.
7
8. Sonkor International Additional Benefits
Sales Presentation: DD Monobloc (1)
Certifications 3D air diffusion Lower Total Costs
TUV CE - ETL - RoHS High Wall Project Savings
Our entire product range is TUV Our unique three-dimensional air distribu- Low installation and maintenance costs
Rheinland or ETL certified. This allows us tion system allows the unit to reach set plus lower risk of refrigerant leaks when
to provide maximum electrical safety and point quickly. This unique feature is not compared to split units, are just some of
reduction of claims. available in conventional window, split, the strengths of our innovative product so-
package type air conditioners. lution.
Additional certifications include CE mark +
RoHS and EMC. Our heat pumps are ideal for manufactur-
ers of mobile homes and container
housing. In the end we provide a winning
solution in terms of total cost.
8
9. Sonkor International High Wall From 32F (0°C) to 125.6F (52°C) External
Sales Presentation: DD Monobloc (1)
iCool ECM
MODEL iCool
High Efficiency
Total cooling capacity kW 2.01 2.01
Heating capacity kW 2.01 2.01
Electric heat booster kW - -
Power input W 837 770
EER rating (Class) W/W 2.49 (B) 2.71 (A)
COP rating (Class) W/W 2.90 (B) 3.20 (A)
Performance Certification Own lab Own lab
Air volume CMH 390 390
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.7 1.0
Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49
Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 950 950
Dimensions - Height mm 430 430
Dimensions - Depth Mm 195 195
Net weight kg 38 39
Wall hole diameter mm 200 200
Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL
9
10. Sonkor International High Wall From 32F (0°C) to 125.6F (52°C) External
Sales Presentation: DD Monobloc (1)
iWarm ECM
MODEL iWarm
High Efficiency
Total cooling capacity kW 2.01 2.01
Heating capacity (incl. electric heat) kW 2.01 (3.61) 2.01 (3.61)
Electric heat booster kW 1.6 1.6
Power input (electric heat) W 837 (1,600) 770 (1,600)
EER rating (Class) W/W 2.49 (B) 2.71 (A)
COP rating (Class) W/W 2.90 (B) 3.20 (A)
Performance Certification Own lab Own lab
Air volume CMH 390 390
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.7 1.0
Indoor sound pressure level @ 1 metre dB(A) 42/46/49 42/46/49
Outdoor sound pressure level @ 1 metre dB(A) 50/56/60 50/56/60
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1010 1010
Dimensions - Height mm 430 430
Dimensions - Depth mm 195 195
Net weight kg 38 39
Wall hole diameter mm 200 200
Certification TUV CE/RoHS/ETL TUV CE/RoHS/ETL
10
11. Sonkor International Low Wall From 25F (–4°C) to 125.6F (52°C) External
Sales Presentation: DD Monobloc (1)
MODEL PTTW-09 PTTW-12
Total cooling capacity kW 2.46 3.25
Heating capacity (incl. electric heat) kW 2.78 3.33 (3.83)
Electric heat booster kW - 500
Power input (electric heat) W 980 1370 (500)
EER rating (Class) W/W 2.53 (B) 2.43 (B)
COP rating (Class) W/W 2.83 (B) 2.60 (C)
Performance Certification Own lab Own lab
Air volume CMH 400 480
Fan speed 3+Auto 3+Auto
Dehumidification l/h 0.8 1.1
Indoor sound pressure level @ 1m dB(A) 37/40/46 37/44/48
Outdoor sound pressure level @ 1m dB(A) 43 41/52
Serial BUS communication (protocol) Optional (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1000 1000
Dimensions - Height mm 580 580
Dimensions - Depth mm 230 245
Net weight kg 40 42
Wall hole diameter mm 162 162
Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL
11
12. Sonkor International Low Wall From 25F (–4°C) to 125.6F (52°C) External
Sales Presentation: DD Monobloc (1)
PTTW-10-ECM PTTW-10-ECM-EH
MODEL
High Efficiency High Efficiency
Total cooling capacity kW 2.90 2.90
Heating capacity (incl. electric heat) kW 2.96 2.96 (4.96)
Electric heat booster kW - 2.00
Power input (electric heat) W 905 905(2000)
EER rating (Class) W/W 3.27 (A++) 3.27 (A++)
COP rating (Class) W/W 3.51 (A++) 3,51 (A++)
Performance Certification SGS Institute SGS Institute
Air volume CMH 450 450
Fan speed 3+Auto 3+Auto
Dehumidification l/h 1.0 1.0
Indoor sound pressure level @ 1m dB(A) 37/44/48 37/44/48
Outdoor sound pressure level @ 1m dB(A) 41/52 41/52
Serial BUS communication (protocol) Standard (MODBUS) Standard (MODBUS)
Electrical supply V/ph/Hz 220/1/60 220/1/60
230/1/50 230/1/50
Refrigerant R410a R410a
Dimensions - Width mm 1000 1000
Dimensions - Height mm 580 580
Dimensions - Depth mm 245 245
Net weight kg 42 42
Wall hole diameter mm 162 mm 162 mm
Certification TUV CE / RoHS / ETL TUV CE / RoHS / ETL
12