SlideShare una empresa de Scribd logo
1 de 26
Descargar para leer sin conexión
104
1
3
Extreme industrial
environments
Air/water heat exchangers
(roof-mounted,
wall-mounted)
Recooling system
1
2
3
105
Heatexchangers
Heat exchangers
1
1
2
2
Air/water heat exchangers
Benefits, technical details 106
Wall mounting, useful cooling output 600/1000 W 108
Wall mounting, useful cooling output 1250/1540 W 110
Wall mounting, useful cooling output 2250/3000/5000 W 112
Roof mounting, useful cooling output 1900/2500/4000 W 114
As a side panel for 600 mm deep TS 8 enclosures,
useful cooling output 700 W 116
One concept, two systems with very different operating methods.
Air/water heat exchangers cool the enclosure internal air via
integration into an existing cooling water circuit or connection to a
recooling system. In this way, extremely high heat loads may be
dissipated.
Practical example of an
air/air heat exchanger
In the paper and wood-processing indus-
tries, for example, particular requirements
are placed on climate control components.
They ensure good ventilation inside the
enclosure, and heat dissipation out of the
enclosure. At the same time, they also pre-
vent the ingress of super-fine dusts.
Air/air heat exchangers are ideal for this
purpose, since they effectively dissipate
the heat from the enclosure with their two
hermetically separate air circuits based on
the reverse current or counter-current prin-
ciple, and prevent the ingress of ambient
air into the enclosure.
The requirement for the use of air/air heat
exchangers is that the ambient tempera-
ture must be below the enclosure internal
temperature.
Standard control units such as thermostat,
hygrostat and speed control for noise mini-
misation, as well as special DC variants,
extend the range of applications, e.g. to
the railway sector.
Practical example of an
air/water heat exchanger
In all areas with extreme ambient condi-
tions, enclosure and climate control com-
ponents are subject to special require-
ments. This applies, for example, to metal
foundries, engine factories and the chemi-
cals and metal-working industries.
In such situations, low-maintenance air/
water heat exchangers are used as effi-
cient all-rounders. Either fed from existing
cooling water networks or from separate
recooling systems, these products contrib-
ute to an ideal climate inside the enclo-
sure. The cooling water absorbs the heat
inside the heat exchanger and conveys it
to the corresponding cooling system. In
this way, even small rooms are not subject
to additional waste heat from the enclo-
sure, and the electronics inside the enclo-
sure are effectively protected.
Air/air heat exchangers utilise the cooler ambient air to cool the
air in the enclosure interior. Based on the counterflow principle,
the completely separate airflows are routed through the heat
exchanger module via high-performance fans. This prevents the
ingress of dust from the environment into the enclosure interior.
Air/air heat exchangers
Benefits, technical details 118
Wall mounting, specific thermal output 17.5 – 60 W/K 120
Wall mounting, specific thermal output 90 W/K 122
Wall mounting, specific thermal output 14.6 – 37 W/K 124
Wall mounting, specific thermal output 42 – 69 W/K 126
Roof mounting, specific thermal output 66 W/K 128
2
2
Wood-processing industry
Air/air heat exchanger (wall-mounted)
1
2
106
Air/water heat exchanger
Benefits, technical details
Rittal system climate control
2
3
3
1
4
The air of the enclosure interior may also be cooled to below the
level of the external temperature, if required, by using cooling
water from a central recooling system. The ingress of dust from
outside into the cooled enclosure is prevented. The waste heat
from the enclosure does not raise the temperature of the ambient
air, provided the heat exchanger and cold water supply system are
spatially separated from one another.
Performance benefits of air/water heat exchangers
Useful cooling output from
600 to 5000 watts
in three mounting variants:
● Wall mounting
● Roof mounting
● Integrated in the TS 8 side
panel. This installation form
uses the space behind the
side panel of the TS 8.
Central cooling as cold water
supplier
By integrating the air/water
heat exchangers into an exist-
ing cooling water circuit or con-
necting to a central recooling
system, the necessary heat
loss can be dissipated with
exceptionally low energy costs.
Also suitable for use in extreme conditions
Ideal at any installation site
If direct dissipation of heat loss
to the ambient air is not desired
or ineffective due to the con-
fined space, the air/water heat
exchanger may offer an ideal
solution. Particularly by sepa-
rating the exchanger from the
recooling system, highly indi-
vidual and effective cooling
solutions for individual enclo-
sures or bayed enclosure
suites may be achieved.
Effective in extreme
conditions
Air/water heat exchangers may
even be used in particularly
extreme ambient temperatures
from +1° to +70° C. Even
extreme levels of contamina-
tion in the ambient air, e.g. with
dust and oil, do not affect
functioning. High heat losses
are dissipated in the most con-
fined spaces, without emitting
them directly to the ambient
air. A high operating ratio is
achieved, thanks to the large
surface area of the heat
exchanger unit.
Also available in stainless
steel
Roof-mounted and wall-
mounted air/water heat
exchangers are available with
all water-carrying parts made
from stainless steel 1.4571
(V4A) for use in extreme con-
ditions.
Example: Parallel connection of
air/water heat exchangers with
cold water supply via a recool-
ing system. Overflow valves
and bypass control should be
integrated into the recooling
system and the customer’s own
pipeline system respectively.
Recooling system
Air/water heat exchanger,
roof-mounted
Air/water heat exchanger,
wall-mounted
Additional cooling water
circuit for machine cooling
1
2
3
4
107Rittal system climate control
Air/waterheatexchanger
Installation and service benefits
Benefits:
● Useful cooling output
from 600 to 5000 watts
● Suitable for use even
under extreme conditions
and ambient tempera-
tures of up to +70°C
● Also available with all
water-carrying parts
made from V4A
● System for TS 8 inte-
grated into the side panel
Important
● Air/water heat exchang-
ers should always be
used in conjunction with
recooling systems or a
cooling water cirucuit
For calculation formulae
and water quality require-
ments,
please see page 188
or refer to the Internet at
www.rittal.de
Compact and lightweight
Air/water heat exchangers
have a low weight and a com-
paratively low volume in rela-
tion to the heat loss to be dissi-
pated. As a result, they are
easily mounted on vertical
enclosure surfaces or on the
roof.
Air/water heat exchanger
integrated into the side panel
This side panel combines
effective heat dissipation with
minimum space requirements.
It may be used in all 600 mm
deep, 1800 mm/2000 mm high
TS 8 enclosures.
Virtually maintenance-free
Because the ingress of ambi-
ent air into the heat exchanger
is prevented, dirt is unable to
penetrate. Control of the air
and water circuit is electroni-
cally monitored.
Control and safety included
High protection category
Thanks to the sealed design, a
protection category of IP 55 to
EN 60 529/10.91 is achieved.
Condensate management
Any condensate arising is dis-
charged via the 1/2˝ tube con-
nector and a discharge hose,
which should be laid with a
gradient ensuring that there are
no kinks. In order to avoid
increased condensation, the
cooling water temperature
should be adapted to match
the required cooling output.
Any condensate occurring may
be disposed of using an exter-
nal electronic condensate
evaporator.
Safety instructions
● When installing the device,
the condensate discharge
must be routed out of the
enclosure!
● In order to avoid frost dam-
age, the minimum permissi-
ble water temperature of
+1°C must not be undercut
at any point in the water
cycle!
● It is vital that the manufactur-
ers’ consent is obtained
before adding anti-freeze!
● During storage and transpor-
tation below freezing point,
the water cycle should be
drained completely using
compressed air!
● Only set the thermostat as
low as is strictly necessary,
since undercutting the dew
point with a falling water inlet
temperature will result in
condensation!
● It is very important that the
enclosure is sealed on all
sides (IP 54), particularly the
cable entry (condensation)!
Roof-mounted heat
exchanger control/monitoring
The enclosure internal temper-
ature is monitored by means of
a thermostatically or electroni-
cally controlled magnetic valve.
It regulates the throughput of
cooling water. If the enclosure
interior temperature rises
above the set level, the float-
ing change-over contact raises
the alarm.
Leak monitoring
of roof-mounted units
In order to ensure that the
enclosure interior is not at risk
from cooling water, the sensor
reports a leak in the event of
water in the corrosion-resistant
base tray.
108 Rittal system climate control
420
200
500
150
Ø 7
80
500
200
18
75
100
2
1
298
240
475
520
Ø 7
298
520
50
135
106
21
420
500
17050
3030
133
150
150
160
200
130
145
160
34Ø 7
4 x
520
298
272
240
475
23012012733
208
Ø 7
Technical specifications:
● All water-carrying parts made from
copper.
● External or internal mounting.
● Small design for optimum space utili-
sation.
● Floating contact in case of overtempera-
ture.
● Ideal for use in extreme ambient condi-
tions.
Supply includes:
Fully wired ready for connection, including
drilling template, sealing mat and assem-
bly parts.
Model No. SK 3214.100 3217.100
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
200
500
100
298
520
135
Useful cooling output
L 35 W 10, 200 l/h
L 35 W 10, 400 l/h
600 W
650 W
1000 W
1100 W
Rated current max. 0.17 A/0.18 A 0.6 A/0.55 A
Pre-fuse T 2.0 A 4.0 A
Cooling medium Water (see specifications on page 188)
Water inlet temperature > +1°C to +30°C
Permissible operating pressure p. max. 1 to 10 bar
Temperature range +1°C to +70°C
Protection category to EN 60 529/10.91 IP 55*
Duty cycle 100%
Type of connection Terminal strip
Weight 7 kg 9.5 kg
Colour RAL 7032
Air throughput of fans 120 m3/h 240 m3/h
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring
Internal thermostat, with changeover contact, switching load 16 A,
setting range +20°C to +60°C (factory setting +35°C)
Special voltages available on request. We reserve the right to make technical modifications. * IP 65 available on request.
Accessories Packs of Page
Temperature indicator 1 3114.100 174
Door-operated switch 1 4127.000 176
Mounting cutout, external mounting
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
SK 3214.100
Mounting holes for internal mounting
SK 3217.100
Mounting holes for internal mounting
Mounting cutout, external mounting
Air/water heat exchanger
Wall mounting, useful cooling output 600/1000 W
109Rittal system climate control
Air/waterheatexchanger
Small design, ideal for the use
with stand-alone enclosures in
conjunction with Mini recooling
systems.
Approvals,
see page 20.
Performance diagrams
(DIN 3168) (50/60 Hz)
Model No. SK
Water resistance curves
Model No. SK
3217.100
TW
Ti
5
250
10 15 20 25 30
500
750
1000
1250
1500
1750
QK
.
45°C
35°C
25°C
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
3217.100
∆P
V
.300 400 500
300
200
100
400
3214.100
∆P
V
.
300 400 500
300
200
100
400
3214.100
45°C
35°C
25°C
.
.
1200
1100
1000
900
800
700
600
500
400
300
200
100
TW
Ti5 10 15 20 25 30 35
QK
.
VW = 400 l/h
VW = 200 l/h
.
.
Tw = Water inlet temperature (°C)
QK = Continuous useful cooling output (W)
Ti = Enclosure internal temperature (°C)
.
Functional diagram
V = Volumetric flow (l/h)
∆P = Water resistance (mbar)
.
Also required:
Cooling water system such as
Rittal recooling systems,
see from page 76 onwards.
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
110 Rittal system climate control
175
170 15
475
25024
126
96
19920
950
164
140
Ø 7 (6 x)
Ø
7
(4
x)
11920
200
140
100
18
75
21
80
950
200
300
133
85
470
200
320
35
75
750
825
25
40
380
Ø 8
825
765
350
380
Ø 8
105
45
85
825
380
2
1
Technical specifications:
● All water-carrying parts made from
copper.
● External or internal mounting.
● Slimline design for optimum space utili-
sation.
● Floating contact in case of overtempera-
ture.
● Ideal for use in extreme ambient condi-
tions.
Supply includes:
Fully wired ready for connection with
terminal strip or connection cable (3 m),
including drilling template, sealing mat
and assembly parts.
Model No. SK 3215.100 3247.000
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
200
950
100
380
825
105
Useful cooling output
L 35 W 10, 200 l/h
L 35 W 10, 400 l/h
1250 W
1300 W
1540 W
1700 W
Rated current max. 0.38 A/0.4 A 0.43 A/0.5 A
Pre-fuse T 4.0 A
Cooling medium Water (see specifications on page 188)
Water inlet temperature > +1°C to +30°C
Permissible operating pressure p. max. 1 to 10 bar
Temperature range +1°C to +70°C
Protection category to EN 60 529/10.91 IP 55*
Duty cycle 100%
Type of connection Terminal strip Connection cable 3 m
Weight 13 kg 17 kg
Colour RAL 7032
Air throughput of fans 200 m3/h 240 m3/h
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring
Internal thermostat, with changeover contact, switching load 16 A,
setting range +20°C to +60°C (factory setting +35°C)
Special voltages available on request. We reserve the right to make technical modifications. * IP 65 available on request.
Accessories Packs of Page
Temperature indicator 1 3114.100 174
Door-operated switch 1 4127.000 176
Mounting cutout, external mounting
SK 3215.100
Mounting holes for internal mounting
SK 3247.000
Mounting holes for internal mounting
Mounting cutout, external mounting
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
Air/water heat exchanger
Wall mounting, useful cooling output 1250/1540 W
111Rittal system climate control
Air/waterheatexchanger
The slimline, compact design
provides space-saving climate
control, even in confined
spaces and at high ambient
temperatures.
Approvals,
see page 20.
Performance diagrams
(DIN 3168) (50/60 Hz)
Model No. SK
Water resistance curves
Model No. SK
3247.000
2250
2000
1750
1500
1250
1000
750
TW
Ti5 10 15 20 25 30
QK
.
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
35°C
45°C
25
°C
3247.000
∆P
V
.400 500 600
300
200
100
400
3215.100
∆P
V
.
200 300 400
300
200
100
400
3215.100
2400
2200
2000
1800
1600
1400
1200
1000
800
600
400
200
TW
Ti
5 10 15 20 25 30 35
QK
.
VW = 400 l/h
VW = 200 l/h
.
.
45°C
35°C
25°C
Tw = Water inlet temperature (°C)
QK = Continuous useful cooling output (W)
Ti = Enclosure internal temperature (°C)
.
Functional diagram
V = Volumetric flow (l/h)
∆P = Water resistance (mbar)
.
Also required:
Cooling water system such as
Rittal recooling systems,
see from page 76 onwards.
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
112 Rittal system climate control
Technical specifications:
● SK 3218.104: All water-carrying parts
made from stainless steel 1.4571 (V4A).
SK 3218.100 and SK 3216.100: All
water-carrying parts made from copper.
● External or internal mounting.
SK 3216.100: Suitable for external
mounting only.
● Compact design for optimum space utili-
sation.
● Floating contact in case of overtempera-
ture.
● Ideal for use in extreme ambient condi-
tions.
Supply includes:
Fully wired ready for connection with
terminal strip, including drilling template,
sealing mat and assembly parts.
Also required:
Cooling water system such as
Rittal recooling systems,
see from page 76 onwards.
Model No. SK 3218.104* 3218.100 3216.100
Rated operating voltage V,l Hz 230, 50/60
Dimensions in mm
W
H
D
400
950
200
450
1400
250
Useful cooling output
L 35 W 10, 200 l/h
L 35 W 10, 400 l/h
2250 W
2650 W
3000 W
3500 W 5000 W
Rated current max. 0.42 A/0.48 A 1.0 A/1.1 A
Pre-fuse T 4.0 A
Cooling medium Water (see specifications on page 188)
Water inlet temperature > +1°C to +30°C
Permissible operating pressure p. max. 1 to 10 bar
Temperature range +1°C to +70°C
Protection category to EN 60 529/10.91 IP 55**
Duty cycle 100%
Type of connection Terminal strip
Weight 19 kg 21 kg 56 kg
Colour RAL 7032
Air throughput of fans 240 m3/h 450 m3/h 1,000 m3/h
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring
Internal thermostat, with changeover contact, switching load 16 A,
setting range +20°C to +60°C (factory setting +35°C)
Special voltages available on request. We reserve the right to make technical modifications. * Delivery times available on request ** IP 65 available on request.
Accessories Packs of Page
Temperature indicator 1 3114.100 174
Door-operated switch 1 4127.000 176
Mounting cutout for
external/internal mounting
Only the 4 mounting holes,
7 mm diameter, are required
for internal mounting.
SK 3218. . . . SK 3216.100
Mounting cutout,
external mounting
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
200
21
400
950
250
100
450
1400
80
21
Ø 7
340
340
400
280
11246360280
904
950
450
350
410
15
33.5440711.5
180
455455
1400
455
433.5
Ø 8
420
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
Air/water heat exchanger
Wall mounted, useful cooling output 2250/3000/5000 W
113Rittal system climate control
Air/waterheatexchanger
Approvals,
see page 20.
Performance diagrams
(DIN 3168) (50/60 Hz)
Model No. SK
Water resistance curves
Model No. SK
3218.100
Ti
1000
3000
5000
2000
4000
35°C
25°C
TW
5 10 15 20 25 30
QK
.
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
45°C
3216.100
∆P
V
.
200 300 400
300
200
100
400
3218.104 / 3218.100
∆P
V
.
300 400 500
400
300
200
500
3218.104
TW
QK
.
5
500
1000
1500
2000
2500
3000
3500
4000
10 15 20 25 30 35 Ti
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
45°C
35°C
25°C
Tw = Water inlet temperature (°C)
QK = Continuous useful cooling output (W)
Ti = Enclosure internal temperature (°C)
.
Functional diagram
V = Volumetric flow (l/h)
∆P = Water resistance (mbar)
.
3216.100
9000
8000
7000
6000
5000
4000
3000
2000
1000
TW
Ti
5 10 15 20 25 30 35
QK
. 45°C
35°C
25°C
VW = 400 l/h
VW = 200 l/h
.
.
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
114 Rittal system climate control
Technical specifications:
● SK 3249.104: All water-carrying parts
made from stainless steel 1.4571 (V4A).
SK 3249.100 and SK 3219.100: All water-
carrying parts made from copper.
● Electronic leak monitoring ensures per-
fect safety of the entire system even with
heavy condensation, and even in the
event of a pipe fracture.
● A wire screen serves as a water trap,
providing additional mechanical protec-
tion against hosed water.
● A fault signal contact is provided for tem-
perature and leak monitoring.
● The unit can be mounted on enclosures
with a depth of 400 mm and above.
Supply includes:
Fully wired ready for connection with
connector, including drilling template,
sealing mat and assembly parts.
Also required:
Cooling water system such as
Rittal recooling systems,
see from page 76 onwards.
Model No. SK 3249.104* 3249.100 3219.100
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
547
280
404
600
400
400
Useful cooling output
L 35 W 10, 200 l/h
L 35 W 10, 400 l/h
1700 W
1900 W
2250 W
2500 W
3330 W/3500 W
4000 W/4300 W
Rated current max. 0.91 A/0.94 A 1.2 A/1.8 A
Pre-fuse T 4.0 A
Cooling medium Water (see specifications on page 188)
Water inlet temperature > +1°C to +30°C
Permissible operating pressure p. max. 1 to 10 bar
Temperature range +1°C to +70°C
Protection category to EN 60 529/10.91 IP 55**
Duty cycle 100%
Type of connection Connector plug
Weight 19 kg 21 kg 42 kg
Colour RAL 7032
Air throughput of fans 390 m3/h 560 m3/h
Temperature control Electronically controlled magnetic valve
Temperature monitoring
Collective fault signal via changeover contact, max. switching load 250 V AC, 8 A,
setting range +20°C to +60°C (factory setting +35°C)
Special voltages available on request. We reserve the right to make technical modifications. * Delivery times available on request. ** IP 65 available on request.
Accessories Packs of Page
Temperature indicator 1 3114.100 174
Door-operated switch 1 4127.000 176
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
SK 3249. . . . SK 3219.100
= Condensate discharge 1/2˝
= Cooling water connection 1/2˝
1
2
= Air outlet3
Ø 8 (4 x)
53
264
280
397
95 310 8723 23
400
210
226
(538)
280
547
404
280
258
391
150.5
436.5 115
35669.5
(591)
42
Ø
224
100
Ø 8 (4 x)
36
17
600
400
103.5
400
35
73
3
= Air outlet3
3
Mounting cutout Mounting cutout
2
1
2
1
Air/water heat exchanger
Roof mounted, useful cooling output 1900/2500/4000 W
115Rittal system climate control
Air/waterheatexchanger
Approvals,
see page 20.
Performance diagrams
(DIN 3168) (50/60 Hz)
Model No. SK
Water resistance curves
Model No. SK
3249.100
1000
500
1500
2000
2500
3000
3500
4000
45°C
TW
Ti
5 10 15 20 25 30
QK
.
25°C
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
35°C
3219.100
∆P
V
.
400 500 600
500
400
300
600
3249.104 / 3249.100
100
400
300
200
500
200 300 400
V
.
∆P
3249.104
5
750
1000
1250
1500
1750
2000
2250
2500
2750
10 15 20 25 30 35
45°C
TW
Ti
QK
.
25°C
VW = 400 l/h
VW = 200 l/h
VW = 100 l/h
.
.
.
35°C
Tw = Water inlet temperature (°C)
QK = Continuous useful cooling output (W)
Ti = Enclosure internal temperature (°C)
.
Functional diagram
V = Volumetric flow (l/h)
∆P = Water resistance (mbar)
.
3219.100
25°C
35°C
45°C
9000
8000
7000
6000
5000
4000
3000
2000
1000
TW
Ti
5 10 15 20 25 30 35
QK
.
VW = 400 l/h
VW = 200 l/h
.
.
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
116 Rittal system climate control
Technical specifications:
● The units are designed as standard as a
TS 8 side panel.
● Suitable for installation as a rear panel
for 600 mm wide TS 8 enclosure (main-
tain an appropriate distance from the
mounting plate; the air inlet and outlet
must not be obstructed).
● The system is designed for use in heavily
contaminated ambient conditions.
● Monitoring of the enclosure internal tem-
perature via a thermostat with a double
switch point.
● Eliminates the time-consuming work of
cutting out air inlet and outlet holes.
Supply includes:
Fully wired ready for connection with termi-
nal strip, sealing material and assembly
parts.
Model No. SK 3316.180 3316.200
Rated operating voltage V, Hz 230, 50/60
To fit TS 8 enclosures mm
D
H
600
1800
600
2000
Useful cooling output L 35 W 10, 100 l/h 700 W
Rated current max. 0.45 A/0.51 A
Pre-fuse T 4.0 A
Cooling medium Water (see specifications on page 188)
Water inlet temperature > +1°C to +35°C
Permissible operating pressure p. max. 1 to 10 bar
Temperature range +1°C to +70°C
Protection category to EN 60 529/10.91 IP 54
Duty cycle 100%
Type of connection Terminal strip
Weight 26 kg
Colour RAL 7032
Air throughput of fans 170 m3/h
Temperature control Thermostat-controlled magnetic valve
Temperature monitoring
Internal thermostat, with changeover contact, switching load 16 A,
setting range +20°C to +60°C (factory setting +35°C)
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Temperature indicator 1 3114.100 174
Door-operated switch 1 4127.000 176
SK 3316.180 SK 3316.200
= Water connections
= Hose 10 mm diameter
= Condensate discharge
1
2
3
390
562
57
496
1501346
1546
1797
495
400
45
1190
40
20
94
2
1
2
3
390
562
57
496
1501346
1546
1997
495
400
45
1190
40
20
94
2
1
2
3
Air/water heat exchanger
As a side panel for 600 mm deep TS 8 enclosures, useful cooling output 700 W
117Rittal system climate control
Air/waterheatexchanger
Approvals,
see page 20.
Performance diagram
(DIN 3168) (50/60 Hz)
Model No. SK
Water resistance diagram
Model No. SK
3316.180 / 3316.200
1200
1100
1000
900
35
800
700
600
500
400
300
200
3025201510
100
5
35
°C
25
°C
45
°C
TW Ti
QK
.
.
.V = 200 l/h
V = 100 l/h
3316.180 / 3316.200
∆P
V
.
200 300 400
300
200
100
400
Tw = Water inlet temperature (°C)
QK = Continuous useful cooling output (W)
Ti = Enclosure internal temperature (°C)
.
Optimum symbiosis between
the TS 8 enclosure profile and
climate control technology,
plus effective space utilisation.
V = Volumetric flow (l/h)
∆P = Water resistance (mbar)
.
Functional diagram
Also required:
Cooling water system such as
Rittal recooling systems,
see from page 76 onwards.
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
118
Air/air heat exchangers
Benefits, technical details
Rittal system climate control
The requirement for use of air/air heat exchangers is that the ambi-
ent temperature must be below the enclosure internal temperature.
Dust and any aggressive ambient air is unable to enter the enclo-
sure interior, thanks to the two separate air circuits.
Outstanding performance and design
In all situations where the ambi-
ent air is sufficient for cooling,
air/air heat exchangers offer
effective, energy-saving solu-
tions. The high specific ther-
mal output is attributable to the
special construction and func-
tional design of the heat
exchangers:
● A large heat exchanger area
with compact dimensions
● Exceptionally conductive
materials and connections
● Fans that may be controlled
separately
● Optimum flow conditions
Variable output from 17.5 to
90 W/K
Identical mounting cutouts for
various specific thermal out-
puts facilitate easy adaptation
of the output to various require-
ments.
Wall-mounted cooling units are
likewise compatible with this
interface. This means that the
same interface on the enclo-
sure may be used for heat
exchangers and cooling units
of different output categories.
Flow and siting conditions
Internal/external mounting
Air/air heat exchangers may
optionally be mounted on the
outside of the enclosure or
inside the enclosure. The slim-
line design facilitates external
mounting on the door, rear
panel and side panels. The
range also includes a special
heat exchanger for roof-mount-
ing.
By diverting the waste air
upwards, this prevents the cre-
ation of disruptive airflows in
front of the enclosures.
The fans in the internal and
external circuit may be acti-
vated separately and thus
adapted ideally to the ambient
conditions.
Internal mountingExternal mounting
119Rittal system climate control
Air/airheatexchangers
Service / assembly benefits
Benefits:
● Specific thermal output
from 17.5 to 90 W/K
● External and internal
circuit may be controlled
separately
● Mounting cutouts and
enclosure dimensions
identical to TopTherm
wall-mounted cooling
units
● Suitable for external and
internal mounting
● Top design identical to
TopTherm wall-mounted
cooling units
Important
● The temperature
difference between the
room temperature and
enclosure internal
temperature will have a
decisive effect on the
heat loss that may be
dissipated.
For calculation basis
see page 189
or refer to the Internet at
www.rittal.de
Simple maintenance
The heat exchanger unit is very
easily removed and cleaned.
The cleverly designed layout
facilitates time-saving, cost-
cutting maintenance.
Reliability benefits
High protection category
Thanks to the seamlessly
sealed heat exchanger mod-
ule, a protection category of
IP 54 to EN 60 529/10.91 is
achieved.
High load capacity
The motors of the fans are
equipped with thermal winding
protection.
Top quality:
Guaranteeing protection
for your electronics.
All devices in the Rittal
TopTherm series are tested in
accordance with the inter-
nationally valid approvals
(GS, UL).
Easily retrofitted
Thanks to the low weight,
simple assembly cutouts and
problem-free attachment of the
heat exchangers, a cabinet or
enclosure may be easily retro-
fitted.
120 Rittal system climate control
280
550
Technical specifications:
● The compact sheet steel structure
comprises an interchangeable heat
exchanger module.
● TopTherm heat exchangers may option-
ally be fitted to the inside (preferably on
the door) or outside (side panel, door,
rear panel or roof) of the enclosure.
Mounting cutouts are identical to the
TopTherm cooling unit range.
● The heat exchanger module is easily
removed, for effortless cleaning.
● All motors are equipped with thermal
winding protection.
● The heat exchanger membranes are
conductively connected to one another
and incorporated into the electrical
safety features.
● The internal and external air circuit may
be connected separately.
● The two separate air circuits effectively
prevent the ingress of dust, humidity or
dirt.
Supply includes:
Fully wired unit ready for connection.
SK 3126.100 SK 3127.100* / SK 3128.100 / SK 3129.100
Model No. SK 3126.100 3127.100 3128.100 3129.100
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
280
550
150
400
950
205
400
950
225
Specific thermal output 17.5 W/K 30 W/K 45 W/K 60 W/K
Fans 2 per heat exchanger
Max. rated current per fan 0.11 A/0.13 A 0.28 A/0.34 A 0.3 A/0.4 A 0.38 A/0.4 A
Power per fan 23 W/27 W 60 W/75 W 70 W/90 W 85 W/90 W
Air throughput of fans
External circuit 265 m3/h / 315 m3/h 480 m3/h / 525 m3/h 600 m3/h / 625 m3/h 860 m3/h / 900 m3/h
Internal circuit 265 m3/h / 315 m3/h 480 m3/h / 525 m3/h 600 m3/h / 625 m3/h 860 m3/h / 900 m3/h
Temperature range –5°C to +55°C
Weight 12 kg 18 kg 19 kg 21 kg
Colour RAL 7035
Protection category to
EN 60 529/10.91
Internal circuit IP 54
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Filter mats 3 3286.300 3286.400 182
Metal filter 1 3286.310 3286.410 183
Thermostat 1 3110.000 175
Temperature indicator 1 3114.100 174
Speed control 1 3120.000 176
205*/225
50
155*/175
150 42
108
Internal
mounting
External
mounting
Mounting cutout,
external mounting
Mounting cutout,
internal mounting
External
mounting
Internal
mounting
Mounting cutout,
external mounting
Mounting cutout,
internal mounting
950
400
400
250
345
280
36.5235
255
950
15
35025
Ø 9.5 (8x)
385
350
18 x 45°
280
(230)
200
254
524
Ø 8 (4x)
Ø 15 (2x)
266
25492
518
550
280
550
501
251
380
Ø 9.5 (4x)
400
370
R6 (4x) 25
920
920
950
2
25x45°
TopTherm air/air heat exchanger
Wall mounted, specific thermal output 17.5 – 60 W/K
121Rittal system climate control
TopThermair/airheatexchanger
Top design for internal and
external mounting.
Approvals,
see page 20.
Functional diagram
122 Rittal system climate control
215 50
165
1580
400
280
350
Ø 13 (8x)
400
35295
380
1580
260
25875
320
275
340
Technical specifications:
● The compact sheet steel structure
comprises an interchangeable heat
exchanger module.
● TopTherm heat exchangers may
optionally be fitted to the inside
(preferably on the door) or outside
(side panel, door, rear panel or roof)
of the enclosure. Mounting cutouts are
identical to the TopTherm cooling unit
range.
● The heat exchanger module is easily
removed, for effortless cleaning.
● All motors are equipped with thermal
winding protection.
● The heat exchanger membranes are
conductively connected to one another
and incorporated into the electrical
safety features.
● The internal and external air circuit may
be connected separately.
● The two separate air circuits effectively
prevent the ingress of dust, humidity or
dirt.
Supply includes:
Fully wired unit ready for connection.
Model No. SK 3130.100
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
400
1580
215
Specific thermal output 90.0 W/K
Fans 2 per heat exchanger
Rated current 1.35 A/1.8 A
Power per fan 105 W/145 W
Air throughput of fans
External circuit 850 m3/h / 945 m3/h
Internal circuit 850 m3/h / 945 m3/h
Temperature range –5°C to +55°C
Weight 34 kg
Colour RAL 7035
Protection category
to EN 60 529/10.91
Internal circuit IP 54
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Filter mats 3 3286.400 182
Metal filter 1 3286.410 183
Thermostat 1 3110.000 175
Temperature indicator 1 3114.100 174
Speed control 1 3120.000 176
External mounting Internal mounting
Mounting cutout,
internal mounting
Mounting cutout,
external mounting
400
370
324
324
Ø 13 (4x)
1558
1554
1535
1580
Ø 12 (2x)
25
R6 (2x)
376
SK 3130.100
TopTherm air/air heat exchanger
Wall mounted, specific thermal output 90 W/K
123Rittal system climate control
TopThermair/airheatexchanger
Optimum space utilisation,
thanks to the minimal equip-
ment depth.
Approvals,
see page 20.
Functional diagram
124 Rittal system climate control
Technical specifications:
● The compact aluminium structure
comprises an interchangeable heat
exchanger module.
● Techline Mini heat exchangers may
optionally be fitted to the inside (prefera-
bly on the door) or outside (side panel,
door, rear panel or roof) of the enclosure.
● The heat exchanger module is easily
removed with 4 screws, for effortless
cleaning.
● All motors are equipped with thermal
winding protection.
● The heat exchanger membranes are
conductively connected to one another
and incorporated into the electrical
safety features.
● The internal and external circuits can be
connected separately; separate routing
effectively prevents the ingress of dust,
moisture and dirt.
Supply includes:
Fully wired unit ready for connection. Fans
are connected via two 3-wire connection
cables, with wire end ferrules.
SK 3125.000 / SK 3126.000 / SK 3127.000
Mounting cutout, internal mounting
SK 3128.000 / SK 3129.000 / SK 3130.000
Mounting cutout, internal mounting
Mounting cutout, external mounting Mounting cutout, external mounting
A (mm) 380.0 500.0 380.0 500.0 780.0 730.0
B (mm) 187.5 187.5 271.5 271.0 271.0 355.0
C (mm) 155.0 155.0 239.0 239.0 239.0 323.0
D (mm) 127.0 127.0 211.0 225.0 220.0 304.0
E (mm) 228.0 348.0 228.0 230.0 460.0 410.0
F (mm) 178.0 298.0 178.0 172.0 296.5 246.5
G (mm) – – – 23.0 25.5 25.5
H (mm) – – – 106.0 160.0 160.0
I (mm) – – – 61.5 40.0 40.0
J (mm) – – – 26.5 30.0 30.0
K (mm) – – – 135.0 160.0 160.0
L (mm) – – – 30.0 62.0 62.0
M (mm) – – – 165.5 231.5 231.5
N (mm) – – – 48.0 36.0 36.0
P (mm) – – – 135.0 82.5 82.5
R (mm) 107.5 107.5 107.5 117.5 127.5 127.5
Model No. SK 3125.000 3126.000 3127.000 3128.000 3129.000 3130.000
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
187.5
380
162.5
187.5
500
162.5
271.5
380
162.5
271
500
110
271
780
110
355
730
110
Specific thermal output 14.6 W/K 18.7 W/K 18.1 W/K 19.5 W/K 30.0 W/K 37.0 W/K
Fans 2 per heat exchanger
Max. rated current per fan 0.28 A/0.25 A 0.36 A/0.45 A
Power per fan 43/42 W 82/103 W
Air throughput of fans
External circuit 260/300 m3/h 570 m3/h
Internal circuit 260/300 m3/h 570 m3/h
Noise level 54 dB (A) 57 dB (A) 61 dB (A) 67.5 dB (A) 64 dB (A)
Temperature range –5°C to +55°C
Weight 4.3 kg 4.9 kg 5.0 kg 5.1 kg 7.4 kg 8.1 kg
Colour Black anodised
Cooling surface 0.62 m2 0.99 m2 0.9 m2 0.63 m2 1.01 m2 1.23 m2
Protection category
to EN 60 529/10.91
Internal circuit IP 54
Connection cable 2 x 3 m 2 x 5 m
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Thermostat 1 3110.000 175
Temperature indicator 1 3114.100 174
Speed control 1 3120.000 176
12
25
A
E
R
76
107
C
R25
76
B
C
D
F
Ø 7
3030
EKK
B
A
D
FHJM
H I
C
R2525R
12
G G
Ø 7
12
L
F
A
25
C
25
25
25
Ø 7
Ø 18
12
25RR25
303035
B
C
D
E7676
MHJ
KEK
H I
F
A
DG G
C
PP
B
R25R25
12
Ø 7
Ø 18
N
L
Techline Mini air/air heat exchangers
Wall mounted, specific thermal output 14.6 – 37 W/K
125Rittal system climate control
TechlineMiniair/airheatexchangers
Techline Mini heat exchangers
for targeted heat dissipation in
particularly confined spaces.
IR registered design
no. DM/013 569
with validity for BE, CH, DE,
ES, FR, IT, LI, LU, NL
Approvals,
see page 21.
Extremely compact, therefore
suitable for flexible use.
Functional diagram
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
126 Rittal system climate control
Technical specifications:
● The compact aluminium structure
comprises an interchangeable heat
exchanger module.
● Techline heat exchangers may optionally
be fitted to the inside (preferably on the
door) or outside (side panel, door, rear
panel or roof) of the enclosure.
● The heat exchanger module is easily
removed with 4 screws, for effortless
cleaning.
● All motors are equipped with thermal
winding protection.
● The heat exchanger membranes are
conductively connected to one another
and incorporated into the electrical
safety features.
● The internal and external circuits can be
connected separately; separate routing
effectively prevents the ingress of dust,
moisture and dirt.
Supply includes:
Fully wired unit ready for connection. Fans
are connected via two 3-wire connection
cables, with wire end ferrules.
SK 3131.000 / SK 3132.000 /
SK 3133.000 / SK 3134.000
Mounting cutout, internal mounting
SK 3135.000 / SK 3136.000
Mounting cutout, internal mounting
Mounting cutout, external mounting Mounting cutout, external mounting
A (mm) 1200.0 1480.0 1480.0 1780.0 1600.0 1780.0
B (mm) 271.0 271.0 439.0 439.0 355.0 439.0
C (mm) 239.0 239.0 407.0 407.0 323.0 407.0
D (mm) 220.0 220.0 388.0 388.0 304.0 388.0
E (mm) 880.0 1160.0 1160.0 1460.0 1280.0 1460.0
F (mm) 716.5 996.5 996.5 1296.5 1196.5 1376.5
G (mm) 25.5 25.5 25.5 25.5 – –
H (mm) 160.0 160.0 160.0 160.0 – –
I (mm) 40.0 40.0 40.0 40.0 – –
J (mm) 30.0 30.0 30.0 30.0 – –
K (mm) 160.0 160.0 160.0 160.0 – –
L (mm) 62.0 62.0 62.0 62.0 – –
M (mm) 231.5 231.5 231.5 231.5 – –
Model No. SK 3131.000 3132.000 3133.000 3134.000 3135.000 3136.000
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
271
1200
110
271
1480
110
439
1480
110
439
1780
110
355
1600
57.5
439
1780
57.5
Specific thermal output 42.0 W/K 44.0 W/K 63.0 W/K 69.0 W/K 44.5 W/K 48.1 W/K
Fans 2 per heat exchanger
Max. rated current per fan 0.36 A/0.45 A 0.25 A/0.29 A
Power per fan 82/103 W 55/65 W
Air throughput of fans
External circuit 570 m3/h 425/460 m3/h
Internal circuit 570 m3/h 425/460 m3/h
Noise level 62 dB (A) 61.5 dB (A) 68 dB (A) 61 dB (A) 64.5 dB (A) 63 dB (A)
Temperature range –5°C to +55°C
Weight 9.3 kg 10.3 kg 12.5 kg 18.9 kg 11.8 kg 14.8 kg
Colour Black anodised
Cooling surface 2.46 m2 3.43 m2 5.44 m2 7.00 m2 2.82 m2 4.03 m2
Protection category
to EN 60 529/10.91
Internal circuit IP 54
Connection cable 2 x 5 m
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Thermostat 1 3110.000 175
Temperature indicator 1 3114.100 174
Speed control 1 3120.000 176
EKK
B
A
D
FHJM
H I
C
127.52525127.5
12
G G
Ø 7
12
L
E160160
B
A
D
231.5
C
F110
144
120
158
25127.525
12
127.5
Ø 4
Ø 7
62
MHJ
KEK
H I
F
A
DG G
C
82.582.5
B
127.525127.525
12
Ø 7
Ø 18
36
L
82.582.5
231.5
160E160
A
D
C
B
144
F110
158
120
127.5127.52525
62
12
Ø 7
Ø 18
36
Ø 4
Techline air/air heat exchangers
Wall mounted, specific thermal output 42 – 69 W/K
127Rittal system climate control
Techlineair/airheatexchangers
Simple cutouts permit retrofit-
ting into pre-installed enclo-
sures.
Approvals,
see page 21.
Effortless cleaning by simply
removing the heat exchanger
module.
Functional diagram
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY
128 Rittal system climate control
420
301360
400
440
320
480
600
Ø 23 (2x)
Ø7(4x)
62 45
50
21
Technical specifications:
● The heat exchanger module and the
enclosure of the heat exchanger form a
single unit, thereby substantially enlarg-
ing the surface area for heat dissipation.
● This design gives the unit an extremely
low weight (16.8 kg) combined with a
high degree of enclosure rigidity.
● The built-in radial fans ensure effective
air circulation, even where the enclosure
is densely packed.
● All motors are equipped with thermal
winding protection.
● As you would expect, the heat
exchanger membranes are conductively
connected to one another and thereby
incorporated into the electrical safety
features.
● The internal and external circuits can be
connected separately; separate routing
effectively prevents the ingress of dust,
moisture and dirt.
Supply includes:
Fully wired unit ready for connection. Fans
are connected via two 3-wire connection
cables, with wire end ferrules.
Model No. SK 3248.000
Rated operating voltage V, Hz 230, 50/60
Dimensions in mm
W
H
D
595
362
440
Specific thermal output 66 W/K
Fans 2 per heat exchanger
Max. rated current per fan 0.35 A
Power per fan 75 W
Air throughput of fans
External circuit 965 m3/h
Internal circuit 965 m3/h
Noise level 62.5 dB (A)
Temperature range –20°C to +55°C
Weight 16.8 kg
Colour Black anodised
Cooling surface 4.40 m2
Protection category (internal circuit)
to EN 60 529/10.91
IP 54
Connection cable approx. 3.0 m
Special voltages available on request. We reserve the right to make technical modifications.
Accessories Packs of Page
Thermostat 1 3110.000 175
Temperature indicator 1 3114.100 174
Speed control 1 3120.000 176
= Air inlet
= Air outlet
1
2
595
362
440
SK 3248.000
Techline air/air heat exchangers
Roof mounted, specific thermal output 66 W/K
129Rittal system climate control
Techlineair/airheatexchangers
Approvals,
see page 21.
Roof-mounted heat exchangers
are also easily retro-fitted.
Functional diagram
IR registered design
no. DM/013 569
with validity for BE, CH, DE,
ES, FR, IT, LI, LU, NL
ENVIRONMENTALLY FRIENDLY
C OO L I N G T E C H N O LO GY

Más contenido relacionado

La actualidad más candente

Comparison between Systems
Comparison between SystemsComparison between Systems
Comparison between SystemsVictor Ashkenazy
 
Our New Line of PTAC's-AC's and Heat Pumps
Our New Line of PTAC's-AC's and Heat PumpsOur New Line of PTAC's-AC's and Heat Pumps
Our New Line of PTAC's-AC's and Heat Pumpsdgeisert
 
Topic 3 District Cooling System
Topic 3 District Cooling SystemTopic 3 District Cooling System
Topic 3 District Cooling Systempnnazz
 
NBC NORMS FOR HVAC SYSTEMS
NBC NORMS FOR HVAC SYSTEMSNBC NORMS FOR HVAC SYSTEMS
NBC NORMS FOR HVAC SYSTEMSasif anwar
 
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.Acmas Technologies Pvt. Ltd.
 
2015 Commercial Products LENNOX
2015 Commercial Products LENNOX2015 Commercial Products LENNOX
2015 Commercial Products LENNOXVictor Neugebauer
 
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFRemko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFDynamic444
 
Introduction to hvac systems
Introduction to hvac systemsIntroduction to hvac systems
Introduction to hvac systemsmichaeljmack
 
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...svfd1721
 
Mechanical systems
Mechanical systemsMechanical systems
Mechanical systemsSunil Surya
 
Air Conditioning case study
Air Conditioning case studyAir Conditioning case study
Air Conditioning case studySona Rawat
 
OSP Magazine August 2015
OSP Magazine August 2015OSP Magazine August 2015
OSP Magazine August 2015Joel Fastow
 
Low Energy Office Proposal
Low Energy Office Proposal Low Energy Office Proposal
Low Energy Office Proposal robatherton
 
Design of HVAC system for commercial building
Design of HVAC system for commercial buildingDesign of HVAC system for commercial building
Design of HVAC system for commercial buildingjayeshmahajan24
 
2014 - SCS Secondary Refrigeration
2014 - SCS Secondary Refrigeration2014 - SCS Secondary Refrigeration
2014 - SCS Secondary RefrigerationBryan Cook
 
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.Acmas Technologies Pvt. Ltd.
 
Thermon Trace Heating Cables - Commercial Capabilities Brochure
Thermon Trace Heating Cables - Commercial Capabilities BrochureThermon Trace Heating Cables - Commercial Capabilities Brochure
Thermon Trace Heating Cables - Commercial Capabilities BrochureThorne & Derrick UK
 

La actualidad más candente (20)

Comparison between Systems
Comparison between SystemsComparison between Systems
Comparison between Systems
 
Our New Line of PTAC's-AC's and Heat Pumps
Our New Line of PTAC's-AC's and Heat PumpsOur New Line of PTAC's-AC's and Heat Pumps
Our New Line of PTAC's-AC's and Heat Pumps
 
Crac systems gb
Crac systems gbCrac systems gb
Crac systems gb
 
Topic 3 District Cooling System
Topic 3 District Cooling SystemTopic 3 District Cooling System
Topic 3 District Cooling System
 
NBC NORMS FOR HVAC SYSTEMS
NBC NORMS FOR HVAC SYSTEMSNBC NORMS FOR HVAC SYSTEMS
NBC NORMS FOR HVAC SYSTEMS
 
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1750 °C) by ACMAS Technologies Pvt Ltd.
 
2015 Commercial Products LENNOX
2015 Commercial Products LENNOX2015 Commercial Products LENNOX
2015 Commercial Products LENNOX
 
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKFRemko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
Remko WKF inverter heat pump/ Bomba de calor inverter Remko WKF
 
Introduction to hvac systems
Introduction to hvac systemsIntroduction to hvac systems
Introduction to hvac systems
 
HVAC System Selection
HVAC System SelectionHVAC System Selection
HVAC System Selection
 
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
Walk in cooler & freezer cold room plant & refrigerated cold storage warehous...
 
Mechanical systems
Mechanical systemsMechanical systems
Mechanical systems
 
Air Conditioning case study
Air Conditioning case studyAir Conditioning case study
Air Conditioning case study
 
Uponor radiant cooling gv
Uponor radiant cooling gvUponor radiant cooling gv
Uponor radiant cooling gv
 
OSP Magazine August 2015
OSP Magazine August 2015OSP Magazine August 2015
OSP Magazine August 2015
 
Low Energy Office Proposal
Low Energy Office Proposal Low Energy Office Proposal
Low Energy Office Proposal
 
Design of HVAC system for commercial building
Design of HVAC system for commercial buildingDesign of HVAC system for commercial building
Design of HVAC system for commercial building
 
2014 - SCS Secondary Refrigeration
2014 - SCS Secondary Refrigeration2014 - SCS Secondary Refrigeration
2014 - SCS Secondary Refrigeration
 
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Bench Top Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
 
Thermon Trace Heating Cables - Commercial Capabilities Brochure
Thermon Trace Heating Cables - Commercial Capabilities BrochureThermon Trace Heating Cables - Commercial Capabilities Brochure
Thermon Trace Heating Cables - Commercial Capabilities Brochure
 

Similar a Rittal Isı Değiştiricileri 104 129

Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075erdinc klima
 
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 erdinc klima
 
Rittal - Re-Cooling - Chiller Ürünleri
Rittal - Re-Cooling - Chiller ÜrünleriRittal - Re-Cooling - Chiller Ürünleri
Rittal - Re-Cooling - Chiller Ürünlerierdinc klima
 
Types of air conditioning for HVAC application
Types of air conditioning for HVAC applicationTypes of air conditioning for HVAC application
Types of air conditioning for HVAC applicationVirtu Institute
 
Cooling Tower Systems
 Cooling Tower Systems Cooling Tower Systems
Cooling Tower SystemsCoolingTower4
 
Under Floor Heating Presentation
Under Floor Heating PresentationUnder Floor Heating Presentation
Under Floor Heating PresentationAnil Kumar Tufchi
 
Packaged air conditioners
Packaged air conditioners Packaged air conditioners
Packaged air conditioners Ar.ADITYA GOEL
 
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEWClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEWHennie Verster
 
Airius Brochure - V2.0 - Low Res
Airius Brochure - V2.0 - Low ResAirius Brochure - V2.0 - Low Res
Airius Brochure - V2.0 - Low ResAlan Baker
 
Temperature and shade regulation in green house
Temperature and shade regulation in green houseTemperature and shade regulation in green house
Temperature and shade regulation in green houseiari
 
BLUEWAY Air cooled water chiller Brochure
BLUEWAY Air cooled water chiller BrochureBLUEWAY Air cooled water chiller Brochure
BLUEWAY Air cooled water chiller BrochureRoger Luo
 
Airconditioning system (ppt)
Airconditioning system (ppt)Airconditioning system (ppt)
Airconditioning system (ppt)Yuri Melliza
 
Water Chilled Airconditioning
Water Chilled AirconditioningWater Chilled Airconditioning
Water Chilled AirconditioningAljon Altiche
 
airconditioningsystem-130910014923-phpapp01.pdf
airconditioningsystem-130910014923-phpapp01.pdfairconditioningsystem-130910014923-phpapp01.pdf
airconditioningsystem-130910014923-phpapp01.pdfshreeyank JAMBHALE
 

Similar a Rittal Isı Değiştiricileri 104 129 (20)

Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
Rittal - İklimlendirme ve Soğutma Ürünleri 024 075
 
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161 Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
Rittal - İklimlendirme ve Soğutma Ürünleri 144 161
 
Rittal - Re-Cooling - Chiller Ürünleri
Rittal - Re-Cooling - Chiller ÜrünleriRittal - Re-Cooling - Chiller Ürünleri
Rittal - Re-Cooling - Chiller Ürünleri
 
Types of air conditioning for HVAC application
Types of air conditioning for HVAC applicationTypes of air conditioning for HVAC application
Types of air conditioning for HVAC application
 
Cooling Tower Systems
 Cooling Tower Systems Cooling Tower Systems
Cooling Tower Systems
 
G y un50_00
G y un50_00G y un50_00
G y un50_00
 
Under Floor Heating Presentation
Under Floor Heating PresentationUnder Floor Heating Presentation
Under Floor Heating Presentation
 
Air conditioning system
Air conditioning systemAir conditioning system
Air conditioning system
 
Packaged air conditioners
Packaged air conditioners Packaged air conditioners
Packaged air conditioners
 
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEWClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
ClimateWizard_Brochure_AUS_CW005_REVE_0515 NEW
 
Airius Brochure - V2.0 - Low Res
Airius Brochure - V2.0 - Low ResAirius Brochure - V2.0 - Low Res
Airius Brochure - V2.0 - Low Res
 
Temperature and shade regulation in green house
Temperature and shade regulation in green houseTemperature and shade regulation in green house
Temperature and shade regulation in green house
 
SEMINAR for Ventilation with heat recovery 2020
SEMINAR for Ventilation with heat recovery 2020SEMINAR for Ventilation with heat recovery 2020
SEMINAR for Ventilation with heat recovery 2020
 
BLUEWAY Air cooled water chiller Brochure
BLUEWAY Air cooled water chiller BrochureBLUEWAY Air cooled water chiller Brochure
BLUEWAY Air cooled water chiller Brochure
 
Harga ariston pemanas air jakarta 082113812149
Harga ariston pemanas air jakarta 082113812149Harga ariston pemanas air jakarta 082113812149
Harga ariston pemanas air jakarta 082113812149
 
Airconditioning system (ppt)
Airconditioning system (ppt)Airconditioning system (ppt)
Airconditioning system (ppt)
 
Cooling_present(EN) - .pdf
Cooling_present(EN) - .pdfCooling_present(EN) - .pdf
Cooling_present(EN) - .pdf
 
Water Chilled Airconditioning
Water Chilled AirconditioningWater Chilled Airconditioning
Water Chilled Airconditioning
 
airconditioningsystem-130910014923-phpapp01.pdf
airconditioningsystem-130910014923-phpapp01.pdfairconditioningsystem-130910014923-phpapp01.pdf
airconditioningsystem-130910014923-phpapp01.pdf
 
Air conditioning system
Air conditioning systemAir conditioning system
Air conditioning system
 

Más de erdinc klima

Tlc temperature-limit-controller
Tlc temperature-limit-controllerTlc temperature-limit-controller
Tlc temperature-limit-controllererdinc klima
 
T ex universal-controller
T ex universal-controllerT ex universal-controller
T ex universal-controllererdinc klima
 
Tcx 14062-hrv-isi-ger-havalandirma-kontroloru
Tcx 14062-hrv-isi-ger-havalandirma-kontroloruTcx 14062-hrv-isi-ger-havalandirma-kontroloru
Tcx 14062-hrv-isi-ger-havalandirma-kontroloruerdinc klima
 
Tcx 12062-universal-controller
Tcx 12062-universal-controllerTcx 12062-universal-controller
Tcx 12062-universal-controllererdinc klima
 
Tcx2 40863 u-opa2-universal-controller
Tcx2 40863 u-opa2-universal-controllerTcx2 40863 u-opa2-universal-controller
Tcx2 40863 u-opa2-universal-controllererdinc klima
 
Tci universal-controller
Tci universal-controllerTci universal-controller
Tci universal-controllererdinc klima
 
M6000 t1-t2-an-air-conditione-controller
M6000 t1-t2-an-air-conditione-controllerM6000 t1-t2-an-air-conditione-controller
M6000 t1-t2-an-air-conditione-controllererdinc klima
 
Fcc 01 free-coolin-controller
Fcc 01 free-coolin-controllerFcc 01 free-coolin-controller
Fcc 01 free-coolin-controllererdinc klima
 
Ec 300-energy-controller
Ec 300-energy-controllerEc 300-energy-controller
Ec 300-energy-controllererdinc klima
 
Tcy3 universa-controller
Tcy3 universa-controllerTcy3 universa-controller
Tcy3 universa-controllererdinc klima
 
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalar
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalarKontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalar
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalarerdinc klima
 
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisi
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisiKontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisi
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisierdinc klima
 
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisi
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisiKontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisi
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisierdinc klima
 
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisiKontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisierdinc klima
 
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisi
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisiKontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisi
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisierdinc klima
 
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisi
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisiKontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisi
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisierdinc klima
 
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisiKontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisierdinc klima
 
Duyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostatDuyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostaterdinc klima
 
Duyar Elemanlar Sensi co px300-co-sensor
Duyar Elemanlar Sensi co px300-co-sensorDuyar Elemanlar Sensi co px300-co-sensor
Duyar Elemanlar Sensi co px300-co-sensorerdinc klima
 
Duyar Elemanlar Vector sensorler
Duyar Elemanlar Vector sensorlerDuyar Elemanlar Vector sensorler
Duyar Elemanlar Vector sensorlererdinc klima
 

Más de erdinc klima (20)

Tlc temperature-limit-controller
Tlc temperature-limit-controllerTlc temperature-limit-controller
Tlc temperature-limit-controller
 
T ex universal-controller
T ex universal-controllerT ex universal-controller
T ex universal-controller
 
Tcx 14062-hrv-isi-ger-havalandirma-kontroloru
Tcx 14062-hrv-isi-ger-havalandirma-kontroloruTcx 14062-hrv-isi-ger-havalandirma-kontroloru
Tcx 14062-hrv-isi-ger-havalandirma-kontroloru
 
Tcx 12062-universal-controller
Tcx 12062-universal-controllerTcx 12062-universal-controller
Tcx 12062-universal-controller
 
Tcx2 40863 u-opa2-universal-controller
Tcx2 40863 u-opa2-universal-controllerTcx2 40863 u-opa2-universal-controller
Tcx2 40863 u-opa2-universal-controller
 
Tci universal-controller
Tci universal-controllerTci universal-controller
Tci universal-controller
 
M6000 t1-t2-an-air-conditione-controller
M6000 t1-t2-an-air-conditione-controllerM6000 t1-t2-an-air-conditione-controller
M6000 t1-t2-an-air-conditione-controller
 
Fcc 01 free-coolin-controller
Fcc 01 free-coolin-controllerFcc 01 free-coolin-controller
Fcc 01 free-coolin-controller
 
Ec 300-energy-controller
Ec 300-energy-controllerEc 300-energy-controller
Ec 300-energy-controller
 
Tcy3 universa-controller
Tcy3 universa-controllerTcy3 universa-controller
Tcy3 universa-controller
 
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalar
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalarKontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalar
Kontrol vanası ve servomotorlar watts v2 bm-v3bm-lineer-vanalar
 
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisi
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisiKontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisi
Kontrol vanası ve servomotorlar gruner kureselmotorluvanalar225serisi
 
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisi
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisiKontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisi
Kontrol vanası ve servomotorlar gruner kuresel motorluvanalar224-235serisi
 
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisiKontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-90-serisi
 
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisi
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisiKontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisi
Kontrol vanası ve servomotorlar esbe rotary-kontrol-vanalari-3 f-serisi
 
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisi
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisiKontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisi
Kontrol vanası ve servomotorlar esbe lineer-vana-motorlari-ala-serisi
 
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisiKontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisi
Kontrol vanası ve servomotorlar esbe rotary-vana-motorlari-ara600-serisi
 
Duyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostatDuyar Elemanlar St fr ex-donma-termostat
Duyar Elemanlar St fr ex-donma-termostat
 
Duyar Elemanlar Sensi co px300-co-sensor
Duyar Elemanlar Sensi co px300-co-sensorDuyar Elemanlar Sensi co px300-co-sensor
Duyar Elemanlar Sensi co px300-co-sensor
 
Duyar Elemanlar Vector sensorler
Duyar Elemanlar Vector sensorlerDuyar Elemanlar Vector sensorler
Duyar Elemanlar Vector sensorler
 

Último

The Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case studyThe Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case studyEthan lee
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Neil Kimberley
 
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒anilsa9823
 
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLSeo
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...Dipal Arora
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...anilsa9823
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayNZSG
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Servicediscovermytutordmt
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfPaul Menig
 
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesMysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesDipal Arora
 
Monte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMMonte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMRavindra Nath Shukla
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024christinemoorman
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst SummitHolger Mueller
 
Socio-economic-Impact-of-business-consumers-suppliers-and.pptx
Socio-economic-Impact-of-business-consumers-suppliers-and.pptxSocio-economic-Impact-of-business-consumers-suppliers-and.pptx
Socio-economic-Impact-of-business-consumers-suppliers-and.pptxtrishalcan8
 
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...lizamodels9
 
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Delhi Call girls
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Lviv Startup Club
 
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Dave Litwiller
 
Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni
 

Último (20)

The Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case studyThe Coffee Bean & Tea Leaf(CBTL), Business strategy case study
The Coffee Bean & Tea Leaf(CBTL), Business strategy case study
 
Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023Mondelez State of Snacking and Future Trends 2023
Mondelez State of Snacking and Future Trends 2023
 
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒VIP Call Girls In Saharaganj ( Lucknow  ) 🔝 8923113531 🔝  Cash Payment (COD) 👒
VIP Call Girls In Saharaganj ( Lucknow ) 🔝 8923113531 🔝 Cash Payment (COD) 👒
 
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRLMONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
MONA 98765-12871 CALL GIRLS IN LUDHIANA LUDHIANA CALL GIRL
 
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...
Call Girls Navi Mumbai Just Call 9907093804 Top Class Call Girl Service Avail...
 
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
Lucknow 💋 Escorts in Lucknow - 450+ Call Girl Cash Payment 8923113531 Neha Th...
 
It will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 MayIt will be International Nurses' Day on 12 May
It will be International Nurses' Day on 12 May
 
Call Girls in Gomti Nagar - 7388211116 - With room Service
Call Girls in Gomti Nagar - 7388211116  - With room ServiceCall Girls in Gomti Nagar - 7388211116  - With room Service
Call Girls in Gomti Nagar - 7388211116 - With room Service
 
Grateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdfGrateful 7 speech thanking everyone that has helped.pdf
Grateful 7 speech thanking everyone that has helped.pdf
 
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best ServicesMysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
Mysore Call Girls 8617370543 WhatsApp Number 24x7 Best Services
 
Monte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSMMonte Carlo simulation : Simulation using MCSM
Monte Carlo simulation : Simulation using MCSM
 
The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024The CMO Survey - Highlights and Insights Report - Spring 2024
The CMO Survey - Highlights and Insights Report - Spring 2024
 
Progress Report - Oracle Database Analyst Summit
Progress  Report - Oracle Database Analyst SummitProgress  Report - Oracle Database Analyst Summit
Progress Report - Oracle Database Analyst Summit
 
Socio-economic-Impact-of-business-consumers-suppliers-and.pptx
Socio-economic-Impact-of-business-consumers-suppliers-and.pptxSocio-economic-Impact-of-business-consumers-suppliers-and.pptx
Socio-economic-Impact-of-business-consumers-suppliers-and.pptx
 
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
Call Girls In DLf Gurgaon ➥99902@11544 ( Best price)100% Genuine Escort In 24...
 
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
Best VIP Call Girls Noida Sector 40 Call Me: 8448380779
 
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
Yaroslav Rozhankivskyy: Три складові і три передумови максимальної продуктивн...
 
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
Enhancing and Restoring Safety & Quality Cultures - Dave Litwiller - May 2024...
 
Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.Eni 2024 1Q Results - 24.04.24 business.
Eni 2024 1Q Results - 24.04.24 business.
 

Rittal Isı Değiştiricileri 104 129

  • 1. 104 1 3 Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system 1 2 3
  • 2. 105 Heatexchangers Heat exchangers 1 1 2 2 Air/water heat exchangers Benefits, technical details 106 Wall mounting, useful cooling output 600/1000 W 108 Wall mounting, useful cooling output 1250/1540 W 110 Wall mounting, useful cooling output 2250/3000/5000 W 112 Roof mounting, useful cooling output 1900/2500/4000 W 114 As a side panel for 600 mm deep TS 8 enclosures, useful cooling output 700 W 116 One concept, two systems with very different operating methods. Air/water heat exchangers cool the enclosure internal air via integration into an existing cooling water circuit or connection to a recooling system. In this way, extremely high heat loads may be dissipated. Practical example of an air/air heat exchanger In the paper and wood-processing indus- tries, for example, particular requirements are placed on climate control components. They ensure good ventilation inside the enclosure, and heat dissipation out of the enclosure. At the same time, they also pre- vent the ingress of super-fine dusts. Air/air heat exchangers are ideal for this purpose, since they effectively dissipate the heat from the enclosure with their two hermetically separate air circuits based on the reverse current or counter-current prin- ciple, and prevent the ingress of ambient air into the enclosure. The requirement for the use of air/air heat exchangers is that the ambient tempera- ture must be below the enclosure internal temperature. Standard control units such as thermostat, hygrostat and speed control for noise mini- misation, as well as special DC variants, extend the range of applications, e.g. to the railway sector. Practical example of an air/water heat exchanger In all areas with extreme ambient condi- tions, enclosure and climate control com- ponents are subject to special require- ments. This applies, for example, to metal foundries, engine factories and the chemi- cals and metal-working industries. In such situations, low-maintenance air/ water heat exchangers are used as effi- cient all-rounders. Either fed from existing cooling water networks or from separate recooling systems, these products contrib- ute to an ideal climate inside the enclo- sure. The cooling water absorbs the heat inside the heat exchanger and conveys it to the corresponding cooling system. In this way, even small rooms are not subject to additional waste heat from the enclo- sure, and the electronics inside the enclo- sure are effectively protected. Air/air heat exchangers utilise the cooler ambient air to cool the air in the enclosure interior. Based on the counterflow principle, the completely separate airflows are routed through the heat exchanger module via high-performance fans. This prevents the ingress of dust from the environment into the enclosure interior. Air/air heat exchangers Benefits, technical details 118 Wall mounting, specific thermal output 17.5 – 60 W/K 120 Wall mounting, specific thermal output 90 W/K 122 Wall mounting, specific thermal output 14.6 – 37 W/K 124 Wall mounting, specific thermal output 42 – 69 W/K 126 Roof mounting, specific thermal output 66 W/K 128 2 2 Wood-processing industry Air/air heat exchanger (wall-mounted) 1 2
  • 3. 106 Air/water heat exchanger Benefits, technical details Rittal system climate control 2 3 3 1 4 The air of the enclosure interior may also be cooled to below the level of the external temperature, if required, by using cooling water from a central recooling system. The ingress of dust from outside into the cooled enclosure is prevented. The waste heat from the enclosure does not raise the temperature of the ambient air, provided the heat exchanger and cold water supply system are spatially separated from one another. Performance benefits of air/water heat exchangers Useful cooling output from 600 to 5000 watts in three mounting variants: ● Wall mounting ● Roof mounting ● Integrated in the TS 8 side panel. This installation form uses the space behind the side panel of the TS 8. Central cooling as cold water supplier By integrating the air/water heat exchangers into an exist- ing cooling water circuit or con- necting to a central recooling system, the necessary heat loss can be dissipated with exceptionally low energy costs. Also suitable for use in extreme conditions Ideal at any installation site If direct dissipation of heat loss to the ambient air is not desired or ineffective due to the con- fined space, the air/water heat exchanger may offer an ideal solution. Particularly by sepa- rating the exchanger from the recooling system, highly indi- vidual and effective cooling solutions for individual enclo- sures or bayed enclosure suites may be achieved. Effective in extreme conditions Air/water heat exchangers may even be used in particularly extreme ambient temperatures from +1° to +70° C. Even extreme levels of contamina- tion in the ambient air, e.g. with dust and oil, do not affect functioning. High heat losses are dissipated in the most con- fined spaces, without emitting them directly to the ambient air. A high operating ratio is achieved, thanks to the large surface area of the heat exchanger unit. Also available in stainless steel Roof-mounted and wall- mounted air/water heat exchangers are available with all water-carrying parts made from stainless steel 1.4571 (V4A) for use in extreme con- ditions. Example: Parallel connection of air/water heat exchangers with cold water supply via a recool- ing system. Overflow valves and bypass control should be integrated into the recooling system and the customer’s own pipeline system respectively. Recooling system Air/water heat exchanger, roof-mounted Air/water heat exchanger, wall-mounted Additional cooling water circuit for machine cooling 1 2 3 4
  • 4. 107Rittal system climate control Air/waterheatexchanger Installation and service benefits Benefits: ● Useful cooling output from 600 to 5000 watts ● Suitable for use even under extreme conditions and ambient tempera- tures of up to +70°C ● Also available with all water-carrying parts made from V4A ● System for TS 8 inte- grated into the side panel Important ● Air/water heat exchang- ers should always be used in conjunction with recooling systems or a cooling water cirucuit For calculation formulae and water quality require- ments, please see page 188 or refer to the Internet at www.rittal.de Compact and lightweight Air/water heat exchangers have a low weight and a com- paratively low volume in rela- tion to the heat loss to be dissi- pated. As a result, they are easily mounted on vertical enclosure surfaces or on the roof. Air/water heat exchanger integrated into the side panel This side panel combines effective heat dissipation with minimum space requirements. It may be used in all 600 mm deep, 1800 mm/2000 mm high TS 8 enclosures. Virtually maintenance-free Because the ingress of ambi- ent air into the heat exchanger is prevented, dirt is unable to penetrate. Control of the air and water circuit is electroni- cally monitored. Control and safety included High protection category Thanks to the sealed design, a protection category of IP 55 to EN 60 529/10.91 is achieved. Condensate management Any condensate arising is dis- charged via the 1/2˝ tube con- nector and a discharge hose, which should be laid with a gradient ensuring that there are no kinks. In order to avoid increased condensation, the cooling water temperature should be adapted to match the required cooling output. Any condensate occurring may be disposed of using an exter- nal electronic condensate evaporator. Safety instructions ● When installing the device, the condensate discharge must be routed out of the enclosure! ● In order to avoid frost dam- age, the minimum permissi- ble water temperature of +1°C must not be undercut at any point in the water cycle! ● It is vital that the manufactur- ers’ consent is obtained before adding anti-freeze! ● During storage and transpor- tation below freezing point, the water cycle should be drained completely using compressed air! ● Only set the thermostat as low as is strictly necessary, since undercutting the dew point with a falling water inlet temperature will result in condensation! ● It is very important that the enclosure is sealed on all sides (IP 54), particularly the cable entry (condensation)! Roof-mounted heat exchanger control/monitoring The enclosure internal temper- ature is monitored by means of a thermostatically or electroni- cally controlled magnetic valve. It regulates the throughput of cooling water. If the enclosure interior temperature rises above the set level, the float- ing change-over contact raises the alarm. Leak monitoring of roof-mounted units In order to ensure that the enclosure interior is not at risk from cooling water, the sensor reports a leak in the event of water in the corrosion-resistant base tray.
  • 5. 108 Rittal system climate control 420 200 500 150 Ø 7 80 500 200 18 75 100 2 1 298 240 475 520 Ø 7 298 520 50 135 106 21 420 500 17050 3030 133 150 150 160 200 130 145 160 34Ø 7 4 x 520 298 272 240 475 23012012733 208 Ø 7 Technical specifications: ● All water-carrying parts made from copper. ● External or internal mounting. ● Small design for optimum space utili- sation. ● Floating contact in case of overtempera- ture. ● Ideal for use in extreme ambient condi- tions. Supply includes: Fully wired ready for connection, including drilling template, sealing mat and assem- bly parts. Model No. SK 3214.100 3217.100 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 200 500 100 298 520 135 Useful cooling output L 35 W 10, 200 l/h L 35 W 10, 400 l/h 600 W 650 W 1000 W 1100 W Rated current max. 0.17 A/0.18 A 0.6 A/0.55 A Pre-fuse T 2.0 A 4.0 A Cooling medium Water (see specifications on page 188) Water inlet temperature > +1°C to +30°C Permissible operating pressure p. max. 1 to 10 bar Temperature range +1°C to +70°C Protection category to EN 60 529/10.91 IP 55* Duty cycle 100% Type of connection Terminal strip Weight 7 kg 9.5 kg Colour RAL 7032 Air throughput of fans 120 m3/h 240 m3/h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 16 A, setting range +20°C to +60°C (factory setting +35°C) Special voltages available on request. We reserve the right to make technical modifications. * IP 65 available on request. Accessories Packs of Page Temperature indicator 1 3114.100 174 Door-operated switch 1 4127.000 176 Mounting cutout, external mounting = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 SK 3214.100 Mounting holes for internal mounting SK 3217.100 Mounting holes for internal mounting Mounting cutout, external mounting
  • 6. Air/water heat exchanger Wall mounting, useful cooling output 600/1000 W 109Rittal system climate control Air/waterheatexchanger Small design, ideal for the use with stand-alone enclosures in conjunction with Mini recooling systems. Approvals, see page 20. Performance diagrams (DIN 3168) (50/60 Hz) Model No. SK Water resistance curves Model No. SK 3217.100 TW Ti 5 250 10 15 20 25 30 500 750 1000 1250 1500 1750 QK . 45°C 35°C 25°C VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 3217.100 ∆P V .300 400 500 300 200 100 400 3214.100 ∆P V . 300 400 500 300 200 100 400 3214.100 45°C 35°C 25°C . . 1200 1100 1000 900 800 700 600 500 400 300 200 100 TW Ti5 10 15 20 25 30 35 QK . VW = 400 l/h VW = 200 l/h . . Tw = Water inlet temperature (°C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature (°C) . Functional diagram V = Volumetric flow (l/h) ∆P = Water resistance (mbar) . Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards. ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 7. 110 Rittal system climate control 175 170 15 475 25024 126 96 19920 950 164 140 Ø 7 (6 x) Ø 7 (4 x) 11920 200 140 100 18 75 21 80 950 200 300 133 85 470 200 320 35 75 750 825 25 40 380 Ø 8 825 765 350 380 Ø 8 105 45 85 825 380 2 1 Technical specifications: ● All water-carrying parts made from copper. ● External or internal mounting. ● Slimline design for optimum space utili- sation. ● Floating contact in case of overtempera- ture. ● Ideal for use in extreme ambient condi- tions. Supply includes: Fully wired ready for connection with terminal strip or connection cable (3 m), including drilling template, sealing mat and assembly parts. Model No. SK 3215.100 3247.000 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 200 950 100 380 825 105 Useful cooling output L 35 W 10, 200 l/h L 35 W 10, 400 l/h 1250 W 1300 W 1540 W 1700 W Rated current max. 0.38 A/0.4 A 0.43 A/0.5 A Pre-fuse T 4.0 A Cooling medium Water (see specifications on page 188) Water inlet temperature > +1°C to +30°C Permissible operating pressure p. max. 1 to 10 bar Temperature range +1°C to +70°C Protection category to EN 60 529/10.91 IP 55* Duty cycle 100% Type of connection Terminal strip Connection cable 3 m Weight 13 kg 17 kg Colour RAL 7032 Air throughput of fans 200 m3/h 240 m3/h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 16 A, setting range +20°C to +60°C (factory setting +35°C) Special voltages available on request. We reserve the right to make technical modifications. * IP 65 available on request. Accessories Packs of Page Temperature indicator 1 3114.100 174 Door-operated switch 1 4127.000 176 Mounting cutout, external mounting SK 3215.100 Mounting holes for internal mounting SK 3247.000 Mounting holes for internal mounting Mounting cutout, external mounting = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2
  • 8. Air/water heat exchanger Wall mounting, useful cooling output 1250/1540 W 111Rittal system climate control Air/waterheatexchanger The slimline, compact design provides space-saving climate control, even in confined spaces and at high ambient temperatures. Approvals, see page 20. Performance diagrams (DIN 3168) (50/60 Hz) Model No. SK Water resistance curves Model No. SK 3247.000 2250 2000 1750 1500 1250 1000 750 TW Ti5 10 15 20 25 30 QK . VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 35°C 45°C 25 °C 3247.000 ∆P V .400 500 600 300 200 100 400 3215.100 ∆P V . 200 300 400 300 200 100 400 3215.100 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 TW Ti 5 10 15 20 25 30 35 QK . VW = 400 l/h VW = 200 l/h . . 45°C 35°C 25°C Tw = Water inlet temperature (°C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature (°C) . Functional diagram V = Volumetric flow (l/h) ∆P = Water resistance (mbar) . Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards. ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 9. 112 Rittal system climate control Technical specifications: ● SK 3218.104: All water-carrying parts made from stainless steel 1.4571 (V4A). SK 3218.100 and SK 3216.100: All water-carrying parts made from copper. ● External or internal mounting. SK 3216.100: Suitable for external mounting only. ● Compact design for optimum space utili- sation. ● Floating contact in case of overtempera- ture. ● Ideal for use in extreme ambient condi- tions. Supply includes: Fully wired ready for connection with terminal strip, including drilling template, sealing mat and assembly parts. Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards. Model No. SK 3218.104* 3218.100 3216.100 Rated operating voltage V,l Hz 230, 50/60 Dimensions in mm W H D 400 950 200 450 1400 250 Useful cooling output L 35 W 10, 200 l/h L 35 W 10, 400 l/h 2250 W 2650 W 3000 W 3500 W 5000 W Rated current max. 0.42 A/0.48 A 1.0 A/1.1 A Pre-fuse T 4.0 A Cooling medium Water (see specifications on page 188) Water inlet temperature > +1°C to +30°C Permissible operating pressure p. max. 1 to 10 bar Temperature range +1°C to +70°C Protection category to EN 60 529/10.91 IP 55** Duty cycle 100% Type of connection Terminal strip Weight 19 kg 21 kg 56 kg Colour RAL 7032 Air throughput of fans 240 m3/h 450 m3/h 1,000 m3/h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 16 A, setting range +20°C to +60°C (factory setting +35°C) Special voltages available on request. We reserve the right to make technical modifications. * Delivery times available on request ** IP 65 available on request. Accessories Packs of Page Temperature indicator 1 3114.100 174 Door-operated switch 1 4127.000 176 Mounting cutout for external/internal mounting Only the 4 mounting holes, 7 mm diameter, are required for internal mounting. SK 3218. . . . SK 3216.100 Mounting cutout, external mounting = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 200 21 400 950 250 100 450 1400 80 21 Ø 7 340 340 400 280 11246360280 904 950 450 350 410 15 33.5440711.5 180 455455 1400 455 433.5 Ø 8 420 = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2
  • 10. Air/water heat exchanger Wall mounted, useful cooling output 2250/3000/5000 W 113Rittal system climate control Air/waterheatexchanger Approvals, see page 20. Performance diagrams (DIN 3168) (50/60 Hz) Model No. SK Water resistance curves Model No. SK 3218.100 Ti 1000 3000 5000 2000 4000 35°C 25°C TW 5 10 15 20 25 30 QK . VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 45°C 3216.100 ∆P V . 200 300 400 300 200 100 400 3218.104 / 3218.100 ∆P V . 300 400 500 400 300 200 500 3218.104 TW QK . 5 500 1000 1500 2000 2500 3000 3500 4000 10 15 20 25 30 35 Ti VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 45°C 35°C 25°C Tw = Water inlet temperature (°C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature (°C) . Functional diagram V = Volumetric flow (l/h) ∆P = Water resistance (mbar) . 3216.100 9000 8000 7000 6000 5000 4000 3000 2000 1000 TW Ti 5 10 15 20 25 30 35 QK . 45°C 35°C 25°C VW = 400 l/h VW = 200 l/h . . ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 11. 114 Rittal system climate control Technical specifications: ● SK 3249.104: All water-carrying parts made from stainless steel 1.4571 (V4A). SK 3249.100 and SK 3219.100: All water- carrying parts made from copper. ● Electronic leak monitoring ensures per- fect safety of the entire system even with heavy condensation, and even in the event of a pipe fracture. ● A wire screen serves as a water trap, providing additional mechanical protec- tion against hosed water. ● A fault signal contact is provided for tem- perature and leak monitoring. ● The unit can be mounted on enclosures with a depth of 400 mm and above. Supply includes: Fully wired ready for connection with connector, including drilling template, sealing mat and assembly parts. Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards. Model No. SK 3249.104* 3249.100 3219.100 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 547 280 404 600 400 400 Useful cooling output L 35 W 10, 200 l/h L 35 W 10, 400 l/h 1700 W 1900 W 2250 W 2500 W 3330 W/3500 W 4000 W/4300 W Rated current max. 0.91 A/0.94 A 1.2 A/1.8 A Pre-fuse T 4.0 A Cooling medium Water (see specifications on page 188) Water inlet temperature > +1°C to +30°C Permissible operating pressure p. max. 1 to 10 bar Temperature range +1°C to +70°C Protection category to EN 60 529/10.91 IP 55** Duty cycle 100% Type of connection Connector plug Weight 19 kg 21 kg 42 kg Colour RAL 7032 Air throughput of fans 390 m3/h 560 m3/h Temperature control Electronically controlled magnetic valve Temperature monitoring Collective fault signal via changeover contact, max. switching load 250 V AC, 8 A, setting range +20°C to +60°C (factory setting +35°C) Special voltages available on request. We reserve the right to make technical modifications. * Delivery times available on request. ** IP 65 available on request. Accessories Packs of Page Temperature indicator 1 3114.100 174 Door-operated switch 1 4127.000 176 = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 SK 3249. . . . SK 3219.100 = Condensate discharge 1/2˝ = Cooling water connection 1/2˝ 1 2 = Air outlet3 Ø 8 (4 x) 53 264 280 397 95 310 8723 23 400 210 226 (538) 280 547 404 280 258 391 150.5 436.5 115 35669.5 (591) 42 Ø 224 100 Ø 8 (4 x) 36 17 600 400 103.5 400 35 73 3 = Air outlet3 3 Mounting cutout Mounting cutout 2 1 2 1
  • 12. Air/water heat exchanger Roof mounted, useful cooling output 1900/2500/4000 W 115Rittal system climate control Air/waterheatexchanger Approvals, see page 20. Performance diagrams (DIN 3168) (50/60 Hz) Model No. SK Water resistance curves Model No. SK 3249.100 1000 500 1500 2000 2500 3000 3500 4000 45°C TW Ti 5 10 15 20 25 30 QK . 25°C VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 35°C 3219.100 ∆P V . 400 500 600 500 400 300 600 3249.104 / 3249.100 100 400 300 200 500 200 300 400 V . ∆P 3249.104 5 750 1000 1250 1500 1750 2000 2250 2500 2750 10 15 20 25 30 35 45°C TW Ti QK . 25°C VW = 400 l/h VW = 200 l/h VW = 100 l/h . . . 35°C Tw = Water inlet temperature (°C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature (°C) . Functional diagram V = Volumetric flow (l/h) ∆P = Water resistance (mbar) . 3219.100 25°C 35°C 45°C 9000 8000 7000 6000 5000 4000 3000 2000 1000 TW Ti 5 10 15 20 25 30 35 QK . VW = 400 l/h VW = 200 l/h . . ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 13. 116 Rittal system climate control Technical specifications: ● The units are designed as standard as a TS 8 side panel. ● Suitable for installation as a rear panel for 600 mm wide TS 8 enclosure (main- tain an appropriate distance from the mounting plate; the air inlet and outlet must not be obstructed). ● The system is designed for use in heavily contaminated ambient conditions. ● Monitoring of the enclosure internal tem- perature via a thermostat with a double switch point. ● Eliminates the time-consuming work of cutting out air inlet and outlet holes. Supply includes: Fully wired ready for connection with termi- nal strip, sealing material and assembly parts. Model No. SK 3316.180 3316.200 Rated operating voltage V, Hz 230, 50/60 To fit TS 8 enclosures mm D H 600 1800 600 2000 Useful cooling output L 35 W 10, 100 l/h 700 W Rated current max. 0.45 A/0.51 A Pre-fuse T 4.0 A Cooling medium Water (see specifications on page 188) Water inlet temperature > +1°C to +35°C Permissible operating pressure p. max. 1 to 10 bar Temperature range +1°C to +70°C Protection category to EN 60 529/10.91 IP 54 Duty cycle 100% Type of connection Terminal strip Weight 26 kg Colour RAL 7032 Air throughput of fans 170 m3/h Temperature control Thermostat-controlled magnetic valve Temperature monitoring Internal thermostat, with changeover contact, switching load 16 A, setting range +20°C to +60°C (factory setting +35°C) Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Temperature indicator 1 3114.100 174 Door-operated switch 1 4127.000 176 SK 3316.180 SK 3316.200 = Water connections = Hose 10 mm diameter = Condensate discharge 1 2 3 390 562 57 496 1501346 1546 1797 495 400 45 1190 40 20 94 2 1 2 3 390 562 57 496 1501346 1546 1997 495 400 45 1190 40 20 94 2 1 2 3
  • 14. Air/water heat exchanger As a side panel for 600 mm deep TS 8 enclosures, useful cooling output 700 W 117Rittal system climate control Air/waterheatexchanger Approvals, see page 20. Performance diagram (DIN 3168) (50/60 Hz) Model No. SK Water resistance diagram Model No. SK 3316.180 / 3316.200 1200 1100 1000 900 35 800 700 600 500 400 300 200 3025201510 100 5 35 °C 25 °C 45 °C TW Ti QK . . .V = 200 l/h V = 100 l/h 3316.180 / 3316.200 ∆P V . 200 300 400 300 200 100 400 Tw = Water inlet temperature (°C) QK = Continuous useful cooling output (W) Ti = Enclosure internal temperature (°C) . Optimum symbiosis between the TS 8 enclosure profile and climate control technology, plus effective space utilisation. V = Volumetric flow (l/h) ∆P = Water resistance (mbar) . Functional diagram Also required: Cooling water system such as Rittal recooling systems, see from page 76 onwards. ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 15. 118 Air/air heat exchangers Benefits, technical details Rittal system climate control The requirement for use of air/air heat exchangers is that the ambi- ent temperature must be below the enclosure internal temperature. Dust and any aggressive ambient air is unable to enter the enclo- sure interior, thanks to the two separate air circuits. Outstanding performance and design In all situations where the ambi- ent air is sufficient for cooling, air/air heat exchangers offer effective, energy-saving solu- tions. The high specific ther- mal output is attributable to the special construction and func- tional design of the heat exchangers: ● A large heat exchanger area with compact dimensions ● Exceptionally conductive materials and connections ● Fans that may be controlled separately ● Optimum flow conditions Variable output from 17.5 to 90 W/K Identical mounting cutouts for various specific thermal out- puts facilitate easy adaptation of the output to various require- ments. Wall-mounted cooling units are likewise compatible with this interface. This means that the same interface on the enclo- sure may be used for heat exchangers and cooling units of different output categories. Flow and siting conditions Internal/external mounting Air/air heat exchangers may optionally be mounted on the outside of the enclosure or inside the enclosure. The slim- line design facilitates external mounting on the door, rear panel and side panels. The range also includes a special heat exchanger for roof-mount- ing. By diverting the waste air upwards, this prevents the cre- ation of disruptive airflows in front of the enclosures. The fans in the internal and external circuit may be acti- vated separately and thus adapted ideally to the ambient conditions. Internal mountingExternal mounting
  • 16. 119Rittal system climate control Air/airheatexchangers Service / assembly benefits Benefits: ● Specific thermal output from 17.5 to 90 W/K ● External and internal circuit may be controlled separately ● Mounting cutouts and enclosure dimensions identical to TopTherm wall-mounted cooling units ● Suitable for external and internal mounting ● Top design identical to TopTherm wall-mounted cooling units Important ● The temperature difference between the room temperature and enclosure internal temperature will have a decisive effect on the heat loss that may be dissipated. For calculation basis see page 189 or refer to the Internet at www.rittal.de Simple maintenance The heat exchanger unit is very easily removed and cleaned. The cleverly designed layout facilitates time-saving, cost- cutting maintenance. Reliability benefits High protection category Thanks to the seamlessly sealed heat exchanger mod- ule, a protection category of IP 54 to EN 60 529/10.91 is achieved. High load capacity The motors of the fans are equipped with thermal winding protection. Top quality: Guaranteeing protection for your electronics. All devices in the Rittal TopTherm series are tested in accordance with the inter- nationally valid approvals (GS, UL). Easily retrofitted Thanks to the low weight, simple assembly cutouts and problem-free attachment of the heat exchangers, a cabinet or enclosure may be easily retro- fitted.
  • 17. 120 Rittal system climate control 280 550 Technical specifications: ● The compact sheet steel structure comprises an interchangeable heat exchanger module. ● TopTherm heat exchangers may option- ally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure. Mounting cutouts are identical to the TopTherm cooling unit range. ● The heat exchanger module is easily removed, for effortless cleaning. ● All motors are equipped with thermal winding protection. ● The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features. ● The internal and external air circuit may be connected separately. ● The two separate air circuits effectively prevent the ingress of dust, humidity or dirt. Supply includes: Fully wired unit ready for connection. SK 3126.100 SK 3127.100* / SK 3128.100 / SK 3129.100 Model No. SK 3126.100 3127.100 3128.100 3129.100 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 280 550 150 400 950 205 400 950 225 Specific thermal output 17.5 W/K 30 W/K 45 W/K 60 W/K Fans 2 per heat exchanger Max. rated current per fan 0.11 A/0.13 A 0.28 A/0.34 A 0.3 A/0.4 A 0.38 A/0.4 A Power per fan 23 W/27 W 60 W/75 W 70 W/90 W 85 W/90 W Air throughput of fans External circuit 265 m3/h / 315 m3/h 480 m3/h / 525 m3/h 600 m3/h / 625 m3/h 860 m3/h / 900 m3/h Internal circuit 265 m3/h / 315 m3/h 480 m3/h / 525 m3/h 600 m3/h / 625 m3/h 860 m3/h / 900 m3/h Temperature range –5°C to +55°C Weight 12 kg 18 kg 19 kg 21 kg Colour RAL 7035 Protection category to EN 60 529/10.91 Internal circuit IP 54 Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Filter mats 3 3286.300 3286.400 182 Metal filter 1 3286.310 3286.410 183 Thermostat 1 3110.000 175 Temperature indicator 1 3114.100 174 Speed control 1 3120.000 176 205*/225 50 155*/175 150 42 108 Internal mounting External mounting Mounting cutout, external mounting Mounting cutout, internal mounting External mounting Internal mounting Mounting cutout, external mounting Mounting cutout, internal mounting 950 400 400 250 345 280 36.5235 255 950 15 35025 Ø 9.5 (8x) 385 350 18 x 45° 280 (230) 200 254 524 Ø 8 (4x) Ø 15 (2x) 266 25492 518 550 280 550 501 251 380 Ø 9.5 (4x) 400 370 R6 (4x) 25 920 920 950 2 25x45°
  • 18. TopTherm air/air heat exchanger Wall mounted, specific thermal output 17.5 – 60 W/K 121Rittal system climate control TopThermair/airheatexchanger Top design for internal and external mounting. Approvals, see page 20. Functional diagram
  • 19. 122 Rittal system climate control 215 50 165 1580 400 280 350 Ø 13 (8x) 400 35295 380 1580 260 25875 320 275 340 Technical specifications: ● The compact sheet steel structure comprises an interchangeable heat exchanger module. ● TopTherm heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure. Mounting cutouts are identical to the TopTherm cooling unit range. ● The heat exchanger module is easily removed, for effortless cleaning. ● All motors are equipped with thermal winding protection. ● The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features. ● The internal and external air circuit may be connected separately. ● The two separate air circuits effectively prevent the ingress of dust, humidity or dirt. Supply includes: Fully wired unit ready for connection. Model No. SK 3130.100 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 400 1580 215 Specific thermal output 90.0 W/K Fans 2 per heat exchanger Rated current 1.35 A/1.8 A Power per fan 105 W/145 W Air throughput of fans External circuit 850 m3/h / 945 m3/h Internal circuit 850 m3/h / 945 m3/h Temperature range –5°C to +55°C Weight 34 kg Colour RAL 7035 Protection category to EN 60 529/10.91 Internal circuit IP 54 Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Filter mats 3 3286.400 182 Metal filter 1 3286.410 183 Thermostat 1 3110.000 175 Temperature indicator 1 3114.100 174 Speed control 1 3120.000 176 External mounting Internal mounting Mounting cutout, internal mounting Mounting cutout, external mounting 400 370 324 324 Ø 13 (4x) 1558 1554 1535 1580 Ø 12 (2x) 25 R6 (2x) 376 SK 3130.100
  • 20. TopTherm air/air heat exchanger Wall mounted, specific thermal output 90 W/K 123Rittal system climate control TopThermair/airheatexchanger Optimum space utilisation, thanks to the minimal equip- ment depth. Approvals, see page 20. Functional diagram
  • 21. 124 Rittal system climate control Technical specifications: ● The compact aluminium structure comprises an interchangeable heat exchanger module. ● Techline Mini heat exchangers may optionally be fitted to the inside (prefera- bly on the door) or outside (side panel, door, rear panel or roof) of the enclosure. ● The heat exchanger module is easily removed with 4 screws, for effortless cleaning. ● All motors are equipped with thermal winding protection. ● The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features. ● The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt. Supply includes: Fully wired unit ready for connection. Fans are connected via two 3-wire connection cables, with wire end ferrules. SK 3125.000 / SK 3126.000 / SK 3127.000 Mounting cutout, internal mounting SK 3128.000 / SK 3129.000 / SK 3130.000 Mounting cutout, internal mounting Mounting cutout, external mounting Mounting cutout, external mounting A (mm) 380.0 500.0 380.0 500.0 780.0 730.0 B (mm) 187.5 187.5 271.5 271.0 271.0 355.0 C (mm) 155.0 155.0 239.0 239.0 239.0 323.0 D (mm) 127.0 127.0 211.0 225.0 220.0 304.0 E (mm) 228.0 348.0 228.0 230.0 460.0 410.0 F (mm) 178.0 298.0 178.0 172.0 296.5 246.5 G (mm) – – – 23.0 25.5 25.5 H (mm) – – – 106.0 160.0 160.0 I (mm) – – – 61.5 40.0 40.0 J (mm) – – – 26.5 30.0 30.0 K (mm) – – – 135.0 160.0 160.0 L (mm) – – – 30.0 62.0 62.0 M (mm) – – – 165.5 231.5 231.5 N (mm) – – – 48.0 36.0 36.0 P (mm) – – – 135.0 82.5 82.5 R (mm) 107.5 107.5 107.5 117.5 127.5 127.5 Model No. SK 3125.000 3126.000 3127.000 3128.000 3129.000 3130.000 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 187.5 380 162.5 187.5 500 162.5 271.5 380 162.5 271 500 110 271 780 110 355 730 110 Specific thermal output 14.6 W/K 18.7 W/K 18.1 W/K 19.5 W/K 30.0 W/K 37.0 W/K Fans 2 per heat exchanger Max. rated current per fan 0.28 A/0.25 A 0.36 A/0.45 A Power per fan 43/42 W 82/103 W Air throughput of fans External circuit 260/300 m3/h 570 m3/h Internal circuit 260/300 m3/h 570 m3/h Noise level 54 dB (A) 57 dB (A) 61 dB (A) 67.5 dB (A) 64 dB (A) Temperature range –5°C to +55°C Weight 4.3 kg 4.9 kg 5.0 kg 5.1 kg 7.4 kg 8.1 kg Colour Black anodised Cooling surface 0.62 m2 0.99 m2 0.9 m2 0.63 m2 1.01 m2 1.23 m2 Protection category to EN 60 529/10.91 Internal circuit IP 54 Connection cable 2 x 3 m 2 x 5 m Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Thermostat 1 3110.000 175 Temperature indicator 1 3114.100 174 Speed control 1 3120.000 176 12 25 A E R 76 107 C R25 76 B C D F Ø 7 3030 EKK B A D FHJM H I C R2525R 12 G G Ø 7 12 L F A 25 C 25 25 25 Ø 7 Ø 18 12 25RR25 303035 B C D E7676 MHJ KEK H I F A DG G C PP B R25R25 12 Ø 7 Ø 18 N L
  • 22. Techline Mini air/air heat exchangers Wall mounted, specific thermal output 14.6 – 37 W/K 125Rittal system climate control TechlineMiniair/airheatexchangers Techline Mini heat exchangers for targeted heat dissipation in particularly confined spaces. IR registered design no. DM/013 569 with validity for BE, CH, DE, ES, FR, IT, LI, LU, NL Approvals, see page 21. Extremely compact, therefore suitable for flexible use. Functional diagram ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 23. 126 Rittal system climate control Technical specifications: ● The compact aluminium structure comprises an interchangeable heat exchanger module. ● Techline heat exchangers may optionally be fitted to the inside (preferably on the door) or outside (side panel, door, rear panel or roof) of the enclosure. ● The heat exchanger module is easily removed with 4 screws, for effortless cleaning. ● All motors are equipped with thermal winding protection. ● The heat exchanger membranes are conductively connected to one another and incorporated into the electrical safety features. ● The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt. Supply includes: Fully wired unit ready for connection. Fans are connected via two 3-wire connection cables, with wire end ferrules. SK 3131.000 / SK 3132.000 / SK 3133.000 / SK 3134.000 Mounting cutout, internal mounting SK 3135.000 / SK 3136.000 Mounting cutout, internal mounting Mounting cutout, external mounting Mounting cutout, external mounting A (mm) 1200.0 1480.0 1480.0 1780.0 1600.0 1780.0 B (mm) 271.0 271.0 439.0 439.0 355.0 439.0 C (mm) 239.0 239.0 407.0 407.0 323.0 407.0 D (mm) 220.0 220.0 388.0 388.0 304.0 388.0 E (mm) 880.0 1160.0 1160.0 1460.0 1280.0 1460.0 F (mm) 716.5 996.5 996.5 1296.5 1196.5 1376.5 G (mm) 25.5 25.5 25.5 25.5 – – H (mm) 160.0 160.0 160.0 160.0 – – I (mm) 40.0 40.0 40.0 40.0 – – J (mm) 30.0 30.0 30.0 30.0 – – K (mm) 160.0 160.0 160.0 160.0 – – L (mm) 62.0 62.0 62.0 62.0 – – M (mm) 231.5 231.5 231.5 231.5 – – Model No. SK 3131.000 3132.000 3133.000 3134.000 3135.000 3136.000 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 271 1200 110 271 1480 110 439 1480 110 439 1780 110 355 1600 57.5 439 1780 57.5 Specific thermal output 42.0 W/K 44.0 W/K 63.0 W/K 69.0 W/K 44.5 W/K 48.1 W/K Fans 2 per heat exchanger Max. rated current per fan 0.36 A/0.45 A 0.25 A/0.29 A Power per fan 82/103 W 55/65 W Air throughput of fans External circuit 570 m3/h 425/460 m3/h Internal circuit 570 m3/h 425/460 m3/h Noise level 62 dB (A) 61.5 dB (A) 68 dB (A) 61 dB (A) 64.5 dB (A) 63 dB (A) Temperature range –5°C to +55°C Weight 9.3 kg 10.3 kg 12.5 kg 18.9 kg 11.8 kg 14.8 kg Colour Black anodised Cooling surface 2.46 m2 3.43 m2 5.44 m2 7.00 m2 2.82 m2 4.03 m2 Protection category to EN 60 529/10.91 Internal circuit IP 54 Connection cable 2 x 5 m Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Thermostat 1 3110.000 175 Temperature indicator 1 3114.100 174 Speed control 1 3120.000 176 EKK B A D FHJM H I C 127.52525127.5 12 G G Ø 7 12 L E160160 B A D 231.5 C F110 144 120 158 25127.525 12 127.5 Ø 4 Ø 7 62 MHJ KEK H I F A DG G C 82.582.5 B 127.525127.525 12 Ø 7 Ø 18 36 L 82.582.5 231.5 160E160 A D C B 144 F110 158 120 127.5127.52525 62 12 Ø 7 Ø 18 36 Ø 4
  • 24. Techline air/air heat exchangers Wall mounted, specific thermal output 42 – 69 W/K 127Rittal system climate control Techlineair/airheatexchangers Simple cutouts permit retrofit- ting into pre-installed enclo- sures. Approvals, see page 21. Effortless cleaning by simply removing the heat exchanger module. Functional diagram ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY
  • 25. 128 Rittal system climate control 420 301360 400 440 320 480 600 Ø 23 (2x) Ø7(4x) 62 45 50 21 Technical specifications: ● The heat exchanger module and the enclosure of the heat exchanger form a single unit, thereby substantially enlarg- ing the surface area for heat dissipation. ● This design gives the unit an extremely low weight (16.8 kg) combined with a high degree of enclosure rigidity. ● The built-in radial fans ensure effective air circulation, even where the enclosure is densely packed. ● All motors are equipped with thermal winding protection. ● As you would expect, the heat exchanger membranes are conductively connected to one another and thereby incorporated into the electrical safety features. ● The internal and external circuits can be connected separately; separate routing effectively prevents the ingress of dust, moisture and dirt. Supply includes: Fully wired unit ready for connection. Fans are connected via two 3-wire connection cables, with wire end ferrules. Model No. SK 3248.000 Rated operating voltage V, Hz 230, 50/60 Dimensions in mm W H D 595 362 440 Specific thermal output 66 W/K Fans 2 per heat exchanger Max. rated current per fan 0.35 A Power per fan 75 W Air throughput of fans External circuit 965 m3/h Internal circuit 965 m3/h Noise level 62.5 dB (A) Temperature range –20°C to +55°C Weight 16.8 kg Colour Black anodised Cooling surface 4.40 m2 Protection category (internal circuit) to EN 60 529/10.91 IP 54 Connection cable approx. 3.0 m Special voltages available on request. We reserve the right to make technical modifications. Accessories Packs of Page Thermostat 1 3110.000 175 Temperature indicator 1 3114.100 174 Speed control 1 3120.000 176 = Air inlet = Air outlet 1 2 595 362 440 SK 3248.000
  • 26. Techline air/air heat exchangers Roof mounted, specific thermal output 66 W/K 129Rittal system climate control Techlineair/airheatexchangers Approvals, see page 21. Roof-mounted heat exchangers are also easily retro-fitted. Functional diagram IR registered design no. DM/013 569 with validity for BE, CH, DE, ES, FR, IT, LI, LU, NL ENVIRONMENTALLY FRIENDLY C OO L I N G T E C H N O LO GY