The document summarizes changes made from HDMI specification 1.3b to 1.3c, including changes to test methods and criteria. Key changes include:
- Revising the maximum dimension for Type C cable tips to 6.3mm.
- Adding valid connection and no connection test methods for cable types other than wire.
- Modifying TMDS data eye diagram and impedance measurement test methods and criteria for active and converter cable types.
- Adding specifications for measuring DDC/CEC capacitance and voltage depending on the cable type and connections.
2. Feature Changes from HDMI 1.3b to 1.3C
• changed overmold dimension of Type C cable
to the tip of the shell to 6.3mm.
• Test method for active,converter and passive cable
• defined valid connection and valid noconnection
for cable type is not quot;wirequot;
3. Translation of Changes from CTS 1.3b to 1.3c
Test ID CTS 1.3b CTS 1.3c
Changed maxmium dimension to tip of the shell for type c connector to
5-1
6.3mm
connect
Or maximum
envelope
Added valid connection(within 100Ω)and valid noconnection
5-2
(exceed 1MΩ)test method for cable type is not quot;wirequot;.
wire
assignment
>for CEC,SCA,SCL,+5V,HPD,Reserved and Ground lines,confirm that each
pin has valid noconnection with any pins at both side excepted
where a connection is specified in the cable wire assignment table.
>if CDF field cable CEC(or SCA,SCL,+5V,HPD,Reserved ,
Ground)connection is quot;Yquot;,confirm that each pins at both ends has valid
connection.
>if CDF field cable Ground(Reserved) connection is quot;Nquot;,then can not
perform this test since test method is TBD.
if CDF field cable type is quot;converterquot;:
5-3
>category 1,use TMDS 1080i signal as 74.25MHz signal and perform all
TMDS data
test under both condition Vicm of 3.1V and 3.3V.
eyediagram
>category 2,use TMDS 1080i singal as 74.25MHz,1080P signal as
165MHz,1080p/48Bit signal as 340MHz signal and perform all test
under both condition Vicm of 3.1V and 3.3V.
4. Translation of Changes from CTS 1.3b to 1.3c
Test ID CTS 1.3b CTS 1.3c
PASS/FAIL
5-4 Renew PASS/FAIL criteria to 151ps/112ps.
criteria Added:
Intra-Pair skew
is 1).if cable type is active,skip this test.
151ps/111p 2).if cable type is converter,a TMDS signal
s Generator is connected to the source side of
the cable and perform test ID 7-7
5-5 PASS/FAIL Added:
1).if cable type is active,skip this test.
Interpair skew criteria
2).if cable type is converter,a TMDS signal
is
Generator is connected to the source side of
2.42ns/1.7
the cable and perform test ID 7-6.
8ns
PASS/FAIL criteria is 2.42ns/1.78ns
Added if cable type is active or converter, skip this test.
5-6
Added if cable type is active or converter, skip this test.
5-7
Added if cable type is active or
5-8
converter,measure the impedance using the
same method for sink impedance measurement(8-
8)with condition either CDF field
Cable_Diff_PowerOn and Cable_Term_Distance is
used
removed and for reserved.
5-9
5. Translation of Changes from CTS 1.3b to 1.3c
Test ID CTS 1.3b CTS 1.3c
No specified DDC/CEC capacitance and voltage
5-10
DDC/CEC Line
1).if CDF cable_DDC(CEC)_connection is quot;Yquot;,and Cable_Type
Capacitance and
is quot;Activequot; or quot;Converterquot;,measure the capacitance using
Voltage
the same method for sink capacitance measurement(8-9),if
CDF field cable_DDC(CEC)_connection is quot;Nquot;,then swap near
and far-end TPA-R and repeat the test above
2).if CDF cable_DDC(CEC)_connection is quot;Nquot;,perform test
according to 8-9 and 7--13 with the following exception:
• If CDF field Cable_Type is “Active” or
“Converter”,testing shall be performed in power ON
state of the Cable DUT only. If CDF field Cable_Type is
“Passive”, testing shall be performed in power Off
state of the Cable DUT only
• Refer to CDF field of Cable_DDC_Conv_cap for the
condition for DDC capacitance measurement under the Test
ID 7-13
• When VSDA, VSCL and VCEC are measured, Source or Sink
device is connected (if necessary) in test ID 7-13 or 8-9
Respectively
6. Translation of Changes from CTS 1.3b to 1.3c
Test ID CTS 1.3b CTS 1.3c
No specified 1).If CDF field Cable_Type is “Wire” or “Passive” then skip this test.
5-11:
Active/Converter
2).If cable type is others, measure the current at the source side and
Cable +5V Power
voltage at the sink side under both condition :supply 4.8V or
5.3V to +5V pin of the source side directly,
drawing 55mA from +5V pin;then supply 0V to +5V pin at the source
side directly and measure the voltage at the sink side.
5-12: 1).If cable type is wire or
No specified
HPD cable_HPD_connection is quot;Yquot;,then skip this test;
Detectsignal
2).test method:supply +5V to +5V pin of the source side directly,then
test it according to 7-12;then supply 0V to +5V pin of the source
side and measure the HPD voltage according to 8-10
5-13 1).If CDF field cable_DDC_connection is quot;Yquot;then skip this test.
No specified
DDC 2).connet cable to a compliant source,test 2 block EDID readable
communication
5-14 1).If CDF field cable_CEC_connection is quot;Yquot;then skip this test.
No specified
CEC
communication 2).test method:use the cable DUT for connection between compliant CEC
source device and TPA-CEC_RR,perform test ID CEC 7-1,7-2,8-1,8-2 .If
cable_undirectional is quot;Yquot;repeat above steps using CEC compliant sink
device instead of CEC compliant source device
9-5 Added if CDF field CEC_ROOt_device is quot;Yquot;,then skip this test.
Physical Address
7. Test equipment Addition
Test equipment CTS 1.3b CTS 1.3c
Added:For DC characteristics testing of source with Type C plugs and
4.2.1.1.4
Tektronix TPA-R-SE with JAE Type A to Type C jig cable
TPA-P for single Ended
DC1DC2STS020A
measurement
Recommended Test Equipment#3:
4.2.1.1.6/4.2.1.1.7
TPA-P with SMA
>Type-A,EFF-HDMI-TPA-P with EFF-E-EDIDTPA(EDID/control breakout
Connection and TPA-R
adapter),available frome Efficere Technologies as part of set ETHDMI-
with SMA Connection
TPA-S.
>Type-c:EFF-HDMIC-TPA-P with EFF-E-EDIDTPA(EDID/control
breakout adapter),available frome Efficere Technologies as part of set
ETHDMIC-TPA-S.
Note:EFF-HDMIC-TPA-P is preliminary and is subject to change with
out notice.
Added 4th test equipment for testing only Type 2 cable emulator
4.2.1.9
test in test ID 8-7
TMDS signal Generator
• (2) Tektronix AWG7102 Arbitrary Waveform Generators (AWG) with
Opt 01 and 06.
• (1) Tektronix AFG3102 Arbitrary Function Generators ( AFG)
• (8) Mini Circuits Bias Tee model number ZX-85 12G+ needed to
connect to the output of the AWG analog ports
• (10 or 12) SMA Cables: Tektronix 174-1428-00 (1.5 meters), as
needed to connect output of Bias Tees to Efficere TPA boards .
• (1) DC Power Supply: To Connect 5V to the +5V Power (P_5V) and
DDC/CEC Ground (P_GND) on TPA-P.
• (1) Tektronix HDMI Fixture Set ET-HDMI-TPA-S
• (1) HT3 software version with Direct Synthesis capability.