SlideShare una empresa de Scribd logo
1 de 103
Descargar para leer sin conexión
Newsbook 2016 / 2017
Automation Technology
3
Inductive sensors
Encoders
Position sensors
Inductive sensors take a leap forward
Kplus sensors: one sensing range for all metals
(11.2016)
(04.2016)
6 - 7
8 - 9
Infrared sensors / red light sensors
This tiny new photocell O8 is the next big thing (11.2016)
Ingeniously simple: display guide for the perfect setting
Capacitive sensors
(11.2016) 10 - 11
Very robust position sensors with 1 mm-thick metal face
Cylinder sensors
(04.2016) 12 - 13
18 - 19
Ultrasonic sensors
Precise object detection under extreme conditions
Object detection for long ranges and difficult surfaces
(04.2016)
(04.2016)
14 - 15
16 - 17
Intelligent incremental encoder with display and IO-Link (04.2016)
Sensors for motion control
28 - 29
Robust speed sensors – also with ATEX approval
Speed sensors
(04.2016) 30 - 31
Decentralised display, preprocessing and conversion of analogue signals
Multifunctional display: speed, time, counter
Systems for pulse evaluation
(11.2016)
(11.2016)
32 - 33
34 - 35
TOP
TOP
TOP
TOP
TOP
TOP
Laser sensors / distance measurement sensors
The next step in photoelectric sensing with distance display
The next step in photoelectric sensing with easy setting
(11.2016)
(11.2016)
20 - 21
22 - 23
Valve feedback systems for rising stem valves and quarter-turn actuators
Valve feedback sensor with easy wiring
Feedback for hand valves
(11.2016)
(11.2016)
24 - 25
26 - 27
TOP
Camera systems for mobile machines
Augmented reality: mobile 3D smart camera with overlay function
Mobile 3D camera – 2D and 3D in one unit
(11.2016)
(11.2016)
Industrial imaging
36 - 37
38 - 39 TOP
TOP
4
Pressure sensors
AS-Interface cable extensions
Process sensors
Pressure transmitters with DEUTSCH, AMP or M12 connector for mobile applications
Hydrostatic level measurement for a wide range of applications
New PT absolute pressure transmitter with different measuring ranges
IO-Link display: process values at a glance
(04.2016)
(04.2016)
(04.2016)
(04.2016)
48 - 49
50 - 51
52 - 53
54 - 55
Calorimetric flow meter for liquids and gases
Flow sensors / flow meters
(04.2016) 56 - 57
Temperature sensors
Two temperature sensors in one
Temperature sensor with easy dial setting
TN sensor with integrated process connection and evaluation electronics
Temperature sensors with DEUTSCH, AMP or M12 connector
(11.2016)
(11.2016)
(04.2016)
(04.2016)
Repeater to extend AS-i networks up to 1000 m (04.2016)
Industrial communication
SafeLine SmartPLC: fail-safe automation system
AS-Interface Safety at Work
(11.2016)
4-port IO-Link master: intelligent connection of sensors
LR DEVICE Parameter setting software via IO-Link master
LR SENSOR Parameter setting software, point-to-point, for IO-Link devices
IO-Link components
(11.2016)
(11.2016)
(11.2016)
AS-Interface controllers / gateways
DataLine SmartPLC: flexible automation system (11.2016)
TOP
TOP
TOP
TOP
TOP
Camera systems for mobile machines
True 3D vision sensor with intelligent functions
3D sensors for mobile machines
MultiViewBox: display up to 4 camera images on one screen
(04.2016
(04.2016
(11.2016)
Industrial imaging
40 - 41
42 - 43
44 - 45
Photoelectric 3D level measurement and point level detection
3D sensors
(11.2016) 46 - 47 TOP
58 - 59
60 - 61
62 - 63
64 - 65
68 - 69
70 - 71
72 - 73
74 - 75
76 - 77
66 - 67
5
RFID 125 kHz / RFID 13.56 MHz
RFID evaluation system DTE with EtherCAT (04.2016)
Identification systems
RFID with CANopen or J1939 interface for mobile machines
RFID 13.56 MHz
(04.2016)
Diagnostic and service units
Real-time clock with CAN interface
CANwireless: wifi and Bluetooth for the CAN bus
(11.2016)
(11.2016)
Systems for mobile machines
Sockets
Always a reliable connection. ecolink M12 – even for special applications
ecolink M12 cables reduce voltage drop
ecolink M12 – the secure connection even in difficult applications
(11.2016)
(11.2016)
(11.2016)
Connection technology
T splitters
ecolink M12 – T splitters for difficult applications (11.2016)
24 V DC switched-mode power supplies
Powerful switched-mode power supply with an enormous power reserve (04.2016)
Power supplies
Accessories
Circuit protection with monitoring function for the 24 V secondary circuit (04.2016)
Splitter boxes
Compact low-profile M8 splitters with secure ecolink connection (11.2016)
78 - 79
80 - 81
82 - 83
84 - 85
86 - 87
88 - 89
90 - 91
94 - 95
96 - 97
98 - 99
92 - 93
6
Position sensors
Inductive sensors
take a leap forward
Inductive sensors
Precise position monitoring
Digital transmission of target
distance
High linearity and repeatability
High IP 69K and wide
temperature range
Function and polarity selectable
via IO-Link
Much more than just a pulse pick-up!
ifm’s new inductive sensors with IO-Link incorporate several functions in
one unit. They can be used as switching sensors with an adjustable switch
point or measuring systems with a measured value transmitted via IO-Link.
The output signal can be set to NC or NO and PNP or NPN allowing many
possible combinations. This keeps the number of different types down,
reducing the cost of stock.
Highest precision
The new sensors are so precise that they detect even minute changes. Even
the true run of a spindle or the tension of a saw blade is reliably detected.
An alarm can be set if the target leaves the detection zone or comes too
close to the sensing face. All data acquired can be transmitted via IO-Link
and recorded. This new development is unbeatable.
7
(11.2016)
Detection
zone
[mm]
Housing
material
f
[Hz]
Order
no.
M12 connector· 3-wire DC
InstallationType Dimensions
[mm]
Operating voltage [V DC] 10...30
Electrical design
DC PNP / NPN can be set
via IO-Link
Output function
Normally open /
normally closed
can be set via IO-Link
Current rating [mA] 100
Reverse polarity protection •
Short-circuit protection •
Protection class III
Switching status indication [LED] yellow
IO-Link
V1.1; COM2;
3 ms cycle time;
smart sensor profiles;
single point mode;
two point mode;
window mode
Further technical data
Connection technology
Type Description Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
For further technical details please visit: www.ifm.com
60 0.375...3.75
coated
brass
600 IF6123M12
M12
M18
M18
Rectangular
Rectangular
60 0.7...7
coated
brass
600 IF6124
60 0.75...7.5
coated
brass
300 IG6615
60 1.3...13
flush
non
flush
flush
non
flush
coated
brass
300 IG6616
M30
M30
65 1.3...13
coated
brass
100 II5973
65 2.3...23
flush
non
flush
coated
brass
100 II5974
40 x 40 2.1...21 PA100 IM5172
40 x 40 2.6...26 PA100 IM5173
flush
non
flush
Ambient
temperature
[°C]
-40...85
-40...85
-40...85
-40...85
-40...85
-40...85
-25...80
-25...80
Protection
rating
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 65, IP 66, IP 67,
IP 68, IP 69K
IP 67
IP 67
Dimensions
Example IF6124
Example IG6616
Example II5974
Type Description Order
no.
Accessories
Angle bracket for type M30,
stainless steel
E10737
Mounting clamp, with end stop
for types M12, PC
E11994
Mounting clamp, with end stop
for types M18, PC
E11995
Mounting clamp, with end stop
for types M30, PC
E11996
Angle bracket for type M12,
stainless steel
E10735
Angle bracket for type M18,
stainless steel
E10736
49
40
M12x1
17
4
M12x1
60
LED 4 x 90°
5
M18x1
35 10
M12x1
60
LED 4 x 90°
49
24
4
53
34
M30x1,5
5
52
65
M12x1
LED 4 x 90°
15
36
8
Inductive sensors
Kplus sensors:
one sensing range
for all metals
Uniform sensing range for the
reliable detection of all metals
Compact dimensions for use in
the smallest of space
Electromagnetic field immune
sensor technology to prevent
incorrect switching
High-quality
stainless steel housing
High reliability thanks
to protection rating from
IP 65 / IP 69K
Constant correction factor
Kplus sensors have the same sensing range for all types of metals. They
are for example perfectly suited for the detection of aluminium, where
conventional sensors show a considerably reduced sensing range.
The high switching frequencies enable the monitoring of fast changing
switching states.
The resistant stainless steel sleeve allows reliable use in oil and coolant
applications. The wide temperature range as well as the high protection
ratings enable universal use of the new Kplus sensors.
Position sensors
9
(04.2016)
Sensing range
[mm]
Current rating
[mA]
Switching
frequency
[Hz]
Order
no.
M12 connector · 3 wire DC PNP · Output function normally open
InstallationType Total length
[mm]
Further technical dataConnection technology
Type Description Order
no.
34
30
M12x1
4
M12x1
45
LED 4 x 90°
17
4
17LED 4 x 90°
35
49
60
M12x1
M12x1
10
M18x1
M12x1
30
45
34
4
LED 4 x 90° 24
M18x1
30 15
M12x1
60
LED 4 x 90°
49
24
4
45
34
30
LED 4 x 90°
M12x1
M30x1,5
5
36
49
60
22,5
M30x1,5
M12x1
LED 4 x 90°
5
36
22,5
45 4 1002000 IFS297M12
M12
M12
M12
M18
M18
45 8 1002000 IFS298
45 10 1002000 IFS299
60 4 1002000 IFS304
M12
M12
60 8 1002000 IFS305
60 10 1002000 IFS306
45 8 1002000 IGS287
45 12 1002000 IGS288
M18
M18
45 15 1002000 IGS289
60 8 1002000 IGS290
M18
M18
60 12 1002000 IGS291
60 15 1002000 IGS292
M30
M30
45 15 1002000 IIS281
60 15 1002000 IIS282
M30 60 22 1002000 IIS283
M30 60 30 1002000 IIS284
flush
non-flush
non-flush
flush
non-flush
non-flush
flush
non-flush
non-flush
flush
non-flush
non-flush
flush
flush
non-flush
non-flush
Operating voltage [V DC] 10...30
Reverse polarity protection •
Short-circuit protection •
Overload protection •
Protection rating
IP 65 / IP 66 / IP 67 /
IP 68 / IP 69K
Protection class III
Ambient temperature [°C] -40...85
Output status indication [LED] yellow (4 x 90°)
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
For further technical details please visit: www.ifm.com
Housing materials
High-grade stainless steel
(316L)
sensing face
LCP
Dimensions
Example IFS297
Example IFS306
Example IGS287
Example IGS292
Example IIS281
Example IIS284
10
Position sensors
Ingeniously simple:
display guide for
the perfect setting
Capacitive sensors
Unique visualisation and
handling concept via LED display
See and compensate switch
point movement
IP 69K gives high ingress
resistance
PNP/NPN, NO/NC, timer
function
For medium temperatures
up to 110 °C
Visualised switch point
The new capacitive sensors stand out not only because of their excellent
technical data but most of all with their new and unique visualisation
concept. Using a 12-LED bar display of the PerformanceLine the user can
always adapt the switch point to suit the application conditions – it is
always in the centre of the display. The green LEDs either side of the switch
point indicate the reliability of the switch point. Deposits, material changes
etc. are displayed directly on the sensor and the user can readjust the
switch point precisely as needed. An imminent error can be detected in
good time and avoided thus minimising the risk of failures or deactivation.
If help is needed with the effects of process changes this is much easier
to explain and rectify with the LED display. Over the phone the user can
describe the LED behaviour and a support engineer can easily advise
corrective measures.
11
(11.2016)
Further technical data
PerfomanceLine · M12 connector ·3 wires
StandardLine · connection cable 2 m PUR· 3 wires
Type Description Order
no.
Mounting accessories
Type Description Order
no.
Operating voltage [V DC] 10...30
Short-circuit protection •
Reverse polarity / overload protection • / •
Ambient temperature [°C] -25...80
Mounting clamp with end stop for
M18 types
E11048
Mounting clamp with end stop for
M30 types
E11049
Fixing clamp with reducing bush for
M18 types
E10076
Fixing clamp with reducing bush for
M30 types
E10077
Mounting adapter for M30 types,
G 1 1/1", POM
E11033
Mounting adapter for M30 types,
G 1 1/4", PVDF
Switching frequency [HZ] 40
Medium temperature [°C] -25...110
Housing material PBT
Type Output stage Sensing range
[mm]
Protection rating/
protection class
Order
no.
Setting range
[mm]
Communication
interface
For further technical details please visit: www.ifm.com
Memory plug, parameter memory
for IO-Link sensors
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
IO-Link master with
Profibus interface
AL1010
IO-Link master with
EtherNet/IP interface
AL1020
USB IO-Link master for parameter setting
and analysis of units
Supported communication protocols:
IO-Link (4.8, 38.4 and 230 kBits/s)
E30390
M30 PNP, NO/NC 25 nf IP 65, IP 67, IP 69K / III KI60000.5...40
M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5300
M30 PNP, NC 25 nf IP 65, IP 67, IP 69K / III KI5301
0.5...40
0.5...40
IO-Link COM 2
IO-Link COM 2
M30 NPN, NC 25 nf IP 65, IP 67, IP 69K / III KI5302
M30 PNP, NO 25 nf IP 65, IP 67, IP 69K / III KI5303
0.5...40
0.5...40
IO-Link COM 2
IO-Link COM 2
M30 PNP, NC 15 qf IP 65, IP 67, IP 69K / III KI5304
M30 PNP, NO 15 qf IP 65, IP 67, IP 69K / III KI5305
0.5...24
0.5...24
IO-Link COM 2
IO-Link COM 2
M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5306
M30 PNP, NC 25 nf IP 65, IP 67, IP 69K / III KI5307
0.5...40
0.5...40
IO-Link COM 2
IO-Link COM 2
M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5308
M30 PNP, NO 25 nf IP 65, IP 67, IP 69K / III KI5309
0.5...40
0.5...40
IO-Link COM 2
IO-Link COM 2
M30 PNP, NC 15 qf IP 65, IP 67, IP 69K / III KI5310
M30 PNP, NO 15 qf IP 65, IP 67, IP 69K / III KI5311
0.5...24
0.5...24
IO-Link COM 2
IO-Link COM 2
M18 NPN, NO 15 nf IP 65, IP 67, IP 69K / III KG5306
M18 PNP, NC 15 nf IP 65, IP 67, IP 69K / III KG5307
0.5...30
0.5...30
IO-Link COM 2
IO-Link COM 2
M18 NPN, NO 15 nf IP 65, IP 67, IP 69K / III KG5308
M18 PNP, NO 15 nf IP 65, IP 67, IP 69K / III KG5309
0.5...30
0.5...30
IO-Link COM 2
IO-Link COM 2
M18 PNP, NC 8 qf IP 65, IP 67, IP 69K / III KG5310
M18 PNP, NO 8 qf IP 65, IP 67, IP 69K / III KG5311
0.5...9
0.5...9
IO-Link COM 2
IO-Link COM 2
IO-Link COM 2
M18 PNP, NO/NC 15 nf IP 65, IP 67, IP 69K / III KG60000.5...30 IO-Link COM 2
Mounting adapter for M18 types,
G 3/4", POM
E43900
Mounting adapter for M18 types,
G 1", PVDF
E43904
IO-Link accessories
StandardLine · M12 connector ·3 wires
12
Position sensors
Very robust
position sensors
with 1 mm-thick
metal face
Cylinder sensors
Extremely pressure resistant
with over 10 million pressure
cycles
Best value performer
Complementary output
provides higher operational
reliability
Standard M12 housing with
ingress-resistant cable entry
Short housing (40 mm) for
extremely low-profile cylinders
Function principle
The new MFH series sensor is suited for flush mounting in various steels.
With its 1.8 mm sensing range it shows reliable switching characteristics.
The new operating principle of this unit is based on a magnetic-inductive
technology that detects only ferromagnetic metals (e.g. steel). It is sealed
by means of an O-ring and a supporting ring towards the pressure area.
Applications
Besides use in hydraulic cylinders, the sensor is also ideal for other hydraulic
components such as valves or pumps. MFH operates reliably for the lifetime
of the cylinder. Furthermore, it is used in mechanical engineering processes,
e.g. in plastic injection-moulding or process industry applications.
Its attractive price means the sensor can also be considered for simple
components where this option used to be too expensive.
13
(04.2016)
For further technical details please visit: www.ifm.com
M12x1
10
1824,8
4
17
M12x1
9,7
7,8
60
Connection technology
Type Description Order
no.
M12 socket,
2 m black, PUR cable, LED
EVC644
Y splitter, ”OR“
M12 connector / 2x M12 socket
EBC117
Y splitter, ”AND“,
M12 connector / 2x M12 socket
EBC118
Type Sensing
range
[mm]
Housing
length
[mm]
LED OutputAmbient
temperature
[°C]
Order
no.
Cable connection
M12 1.8 f40 • PNP, NO-25...85 MFH205
M12 1.8 f40 • NPN NO-25...85 MFH206
M12 1.8 f40 • PNP, NC-25...85 MFH207
M12 1.8 f40 • PNP, NO/NC-25...85 MFH208
M12 1.8 f60 – PNP, NO/NC-25...120 MFH209
Operating voltage [V] 10...36 DC
Current rating [mA] 200
Switching frequency [Hz] 1000
Short-circuit protection,
pulsed
•
Protected against reverse polarity /
overload protected
• / •
Operating pressure [bar] 500
Pressure rating , static [bar] 1000
Burst pressure [bar] 2000
Protection rating,
protection class
IP 65 / IP 68 / IP 69K,
III
Housing material
stainless steel
1.4404
Common technical data
Accessories
Type Description Order
no.
Optical particle monitor LDP100
Seal process connection,
set 5 O-rings + 5 supporting rings
E12451
Switched-mode power supply
24 V DC / 5 A, metal housing
DN4012
Dimensions
Example MFH205
MFH209
Wiring
M12 connector, complementary
M12 socket,
2 m black, PUR cable
EVC001
MFH205 MFH209
10
1820
4
17
M12x1
9,7
7,8
40
BN
BK
BU
L+
L
4
L
L+
1
2
32:
4:
14
Position sensors
Precise
object detection
under extreme
conditions
Ultrasonic sensors
Robust high-grade stainless
steel housing for demanding
applications
Sensing range up to 1.2 m in
M18 cube design and 2.2 m
in M18 design
The vibrating sound transducer
reduces the deposit of dirt
Retro-reflective operation for
orientation-independent object
detection
Easy setting via teach button,
wire teach or IO-Link
The alternative for difficult surfaces
Ultrasonic sensors transmit and receive sound waves in the ultrasonic
range. The object to be detected reflects the sound waves and the distance
information is determined via time of flight measurement. As opposed to
photoelectric sensors, colour, transparency or the object’s surface shine do
not play a role. Blister packages in packaging technology or transparent
plastic bowls in the food industry, for example, can be reliably detected.
High performance
The ifm ultrasonic sensors in M18 design provide a particularly small blind
zone and long sensing ranges which are usually only achieved by sensors of
a considerably larger design.
The sensors operate reliably with heavy soiling so that they can be used in
applications in which photoelectric sensors meet their limits.
15
(04.2016)
For further technical details please visit: www.ifm.com
Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole
Housing length/
dimensions
[mm]
Setting
60
Type
Wire
Order
no.
UGT500
300 mm*
Order
no.
UGT503
800 mm*
Order
no.
UGT506
1200 mm*
Order
no.
–
1600 mm*
* Max. range
Output
PNP
60 Wire UGT501 UGT504 UGT507 –4...20 mA
60 Wire UGT502 UGT505 UGT508 –0...10 V
Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole
53 x 20 x 38 Pushbutton UGT580
300 mm*
UGT582
800 mm*
UGT584
1200 mm*
–
1600 mm*
PNP + 4…20 mA
53 x 20 x 38 Pushbutton UGT581 UGT583 UGT585 –PNP + 0…10 V
53 x 20 x 38 Pushbutton UGT586 UGT588 UGT590 –NPN + 4…20 mA
53 x 20 x 38 Pushbutton UGT587 UGT589 UGT591 –NPN + 0…10 V
Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole
98 Pushbutton, IO-Link –
300 mm*
–
800 mm*
–
1200 mm*
UGT509
1600 mm*
2 x PNP
98
98
98
98
98
Pushbutton, IO-Link – – –
– – –
– – –
– – –
– – –
UGT510PNP + 4…20 mA
Pushbutton, IO-Link UGT511PNP + 0…10 V
Pushbutton UGT5152x NPN
Pushbutton UGT516NPN + 4…20 mA
Pushbutton UGT517NPN + 0…10 V
Ultrasonic retro-reflective sensor · 3-wire DC, 3-pole
98
M18
M18
M18
M18 Cube
M18 Cube
M18 Cube
M18 Cube
M18
M18
M18
M18
M18
M18
M18 Pushbutton, IO-Link –
300 mm*
–
800 mm*
–
1200 mm*
UGR500
1600 mm*
Order
no.
–
2200 mm*
–
–
–
2200 mm*
–
–
–
UGT512
2200 mm*
UGT513
UGT514
UGT518
UGT519
UGT520
UGR501
2200 mm*
PNP
Accessories
Type Description Order
no.
Mounting set for clamp mounting,
diecast zinc, Ø 12 mm
E20720
Mounting set for clamp mounting,
stainless steel, Ø 12 mm
E21206
Mounting set for clamp mounting,
diecast zinc, Ø 12 mm
E20721
Mounting set for clamp mounting,
stainless steel, Ø 12 mm
E21207
Rod, 100 mm, Ø 12 mm,
M10 thread, stainless steel
E20938
Rod, 200 mm, Ø 10 mm,
M10 thread, stainless steel
E20940
Cube for mounting on an aluminium
profile, M10 thread, diecast zinc
E20951
Common technical data
Operating voltage [V DC] 10...30
Temperature compensation •
Operating temperature range [°C] -20...70
Current rating [mA]
Switching output
100
Protection IP 67
Echo LED green
Status indications LED yellow
Connection M12 connector
Connection technology
Type Description Order
no.
Socket, M12, 4-pole
2 m orange, PVC cable
Socket, M12, 4-pole
5 m orange, PVC cable
Socket, M12, 4-pole
2 m black, PUR cable
Socket, M12, 4-pole
5 m black, PUR cable
Socket, M12, 4-pole
2 m black, PUR cable
Socket, M12, 4-pole
5 m black, PUR cable
60 Wire UGT521 UGT522 UGT523 –NPNM18 –
98M18 Pushbutton – – – UGR502 UGR503NPN
EVT064
EVT001
EVC001
EVC002
EVC004
EVC005
16
Position sensors
Object detection
for long ranges and
difficult surfaces
Ultrasonic sensors
M18 plastic housing available
in the two lengths 60 mm and
98 mm
Long ranges from 300 mm to
2200 mm available
The vibrating sound transducer
reduces the deposit of dirt
Digital and analogue output
for point level measurement
and distance detection
Easy setting via teach button,
wire teach or IO-Link
The alternative for difficult surfaces
Ultrasonic sensors transmit and receive sound waves in the ultrasonic
range. The object to be detected reflects the sound waves and the distance
information is determined via time of flight measurement. As opposed to
photoelectric sensors colour, transparency or the object’s surface shine do
not play a role. Blister packages in packaging technology or transparent
plastic bowls in the food industry, for example, can be reliably detected.
High performance
The ifm ultrasonic sensors in M18 design provide a particularly small blind
zone and long sensing ranges which are usually only achieved by sensors
of a considerably larger design.
The sensors operate reliably with heavy soiling so that they can be used in
applications in which photoelectric sensors meet their limits.
17
(04.2016)
For further technical details please visit: www.ifm.com
Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole
Housing length/
dimensions
[mm]
Setting
60
Type
Wire
Order
no.
300 mm*
Order
no.
800 mm*
Order
no.
1200 mm*
Order
no.
–
1600 mm*
* Max. range
Output
PNP
Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole
98 Pushbutton, IO-Link –
300 mm*
–
800 mm*
–
1200 mm* 1600 mm*
2 x PNP
98
98
Pushbutton, IO-Link – – –
– – –
PNP + 4…20 mA
Pushbutton, IO-Link PNP + 0…10 V
M18
M18
M18
M18
Order
no.
–
2200 mm*
2200 mm*
Accessories
Type Description Order
no.
Mounting set for clamp mounting,
diecast zinc, Ø 12 mm
E20720
Mounting set for clamp mounting,
stainless steel, Ø 12 mm
E21206
Mounting set for clamp mounting,
diecast zinc, Ø 12 mm
E20721
Mounting set for clamp mounting,
stainless steel, Ø 12 mm
E21207
Rod, 100 mm, Ø 12 mm,
M10 thread, stainless steel
E20938
Rod, 200 mm, Ø 10 mm,
M10 thread, stainless steel
E20940
Cube for mounting on an aluminium
profile, M10 thread, diecast zinc
E20951
Common technical data
Operating voltage [V DC] 10...30
Temperature compensation •
Operating temperature range [°C] -20...70
Current rating [mA]
Switching output
100
Protection IP 67
Echo LED green
Status indications LED yellow
Connection M12 connector
Connection technology
Type Description Order
no.
Socket, M12, 4-pole
2 m black, PUR cable
EVC001
Socket, M12, 4-pole
5 m black, PUR cable
EVC002
Socket, M12, 4-pole
2 m black, PUR cable
EVC004
Socket, M12, 4-pole
5 m black, PUR cable
EVC005
L+
L
3
4
2
1
Wiring
Example UGT204
UGT200 UGT201 UGT202
UGT203
UGT204
UGT205
UGT206
UGT207
UGT208
60 Wire UGT209 UGT210 UGT211 –NPNM18 –
18
Position sensors
This tiny new
photocell O8 is the
next big thing!
Infrared sensors / red light sensors
Extremely reliable
background suppression
Range up to 80 mm
independent of the colour
Precise detection of very
small components
Reliable detection of dark or
shiny surfaces
IO-Link for remote setting
Photoelectric miniature sensor with maximum precision
The new powerful O8 sensor is an optimum choice for applications where
space is at a premium such as assembly and robotics. It might be small, but
the sensor achieves a range of 80 mm independent of colour and finish
of the surface to be detected. Moreover the background suppression is
extremely reliable and precise even for the detection of very small, flat or
reflective objects. The O8 reliably copes even with constantly changing
backgrounds, e.g. on robot arms.
Reliable and efficient thanks to IO-Link
Via IO-Link the ranges can be set to the nearest millimetre. A complex
adjustment of the distance from the sensor to the object is not needed.
The new sensors are also available with preset ranges. With their reliability
and precision they are much above the average of conventional devices.
19
(11.2016)
For further technical details please visit: www.ifm.com
Diffuse reflection sensor with background suppression · 3 wires DC
Range
[mm]
Spot Ø at
max. range
[mm]
15
Type
[H, W, D]
4
Order
no.
O8H200
PNP
IO-Link 1.1
Connection Order
no.
O8H201
15 4 O8H202
2 m, PVC cable
0.3 m PVC cable / M8 connector, 3 poles O8H203
15 4 O8H204 O8H205
30 4 O8H206
0.3 m PVC cable / M8 connector, 4 poles
2 m, PVC cable O8H207
30 4 O8H208 O8H209
30 4 O8H210
0.3 m PVC cable / M8 connector, 3 poles
0.3 m PVC cable / M8 connector, 4 poles O8H211
50 4 O8H212 O8H213
50 4 O8H214
2 m, PVC cable
0.3 m PVC cable / M8 connector, 3 poles O8H215
50 4 O8H216 O8H217
80 4.5 O8H218
0.3 m PVC cable / M8 connector, 4 poles
2 m, PVC cable O8H219
80 4.5 O8H220 O8H221
80 4.5 O8H222
0.3 m PVC cable / M8 connector, 3 poles
0.3 m PVC cable / M8 connector, 4 poles O8H223
NPN
Accessories
Type Description Order
no.
Angle bracket for free-standing
mounting, quick mounting, stainless steel
E21289
Common technical data
Operating voltage [V DC] 10...30
Switching frequency [Hz] 1000
Protection rating,
protection class
IP65 / IP67
III
Type of light / wave length red light, 633 mm
Output
H = light-on / D = dark-on mode
H
Switching status indication LED yellow
Voltage drop [V] < 2.5
Short-circuit protection, pulsed •
Reverse polarity /
overload protection
• / •
Ambient temperature [°C] -25...60
Materials housing
lens
ABS; SUS316L
PMMA
Current rating [mA] 100
Operation LED green
Connection technology
Type Description Order
no.
Socket, M8, 4 poles
2 m black, PUR cable
EVC150
Socket, M8, 4 poles
5 m black, PUR cable
EVC151
Socket, M8, 3 poles
2 m black, PUR cable
EVC141
Socket, M8, 3 poles
5 m black, PUR cable
EVC142
Socket, M8, 4 poles,
2 m orange, PVC cable
EVT134
Socket, M8, 4 poles,
5 m orange, PVC cable
EVT135
8,1
8,85,5
28,1
M3
14,4
12,1
133
3,5
2xLED
Dimensions
Example O8H200
Angle bracket for free-standing
mounting, stainless steel
E21291
Rectangular
28.1 x 8.1 x
14.4 mm
20
Position sensors
The next step in
photoelectric sensing
with distance display
Laser sensors /
distance measurement sensors
Reliable background
suppression even at 2 m
Detects any surface finish
or colour
Not fooled by hi-vis
Remote setting via IO-Link
adds many options
New improved performance
Time of flight technology as standard sensor
The O5D with time of flight technology (PMD = Photonic Mixer Device)
combines the following advantages: long range, reliable background
suppression, visible laser light and high excess gain. In the same price range
as standard sensors, it is a clever alternative.
Easy handling
The switch point is set easily to the nearest centimetre via ”+/-“ buttons
and display or alternatively via IO-Link, allowing read-out of the actual value.
Any surface and mounting position
Polished, matt, dark or light objects of any colour: the O5D features reliable
background suppression. The unit allows any angle of incidence and thus
flexibility of mounting. This simplifies installation and saves costs.
21
(11.2016)
For further technical details please visit: www.ifm.com
Common technical data
Operating voltage [V DC] 10...30
Current consumption [mA] < 75
Switching frequency [Hz] 11
Dimensions [mm] 56 x 18.2 x 46.5
Type of light
visible laser light
650 nm
Extraneous light on the object [klx] max. 10
Switching status indication LED yellow
Operation LED green
Distance value
3-digit
alphanumeric
display
Protection rating,
protection class
IP 65, IP 67
III
Short-circuit protection, pulsed •
Reverse polarity /
overload protection
• / •
Ambient temperature [°C] -25...60
Current rating [mA] 2 x 100
Output function
OUT1: NO
OUT2: NC
Connection technology
Type Description Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Photoelectric distance sensor · M12 connector, complementary
30...2000 ...20 PNP < 2.5* < 5 O5D101
30...2000 ...20 O5D100PNP < 2.5* < 5 cm
inch
Material housing / connector
front pane / LED window
bezel
control panel
PA
PMMA
stainless steel
TPU
Accessories
Type Description Order
no.
Mounting bracket for rod,
complete set incl. clamp
E21083
Protective bracket for rod,
complete set incl. clamp
E21084
Bracket for free-standing mounting E21087
Cube for mounting on an aluminium
profile, M10 thread, diecast zinc
E20951
Measuring
range
[mm]
Background
suppression
[m]
Output Hysteresis
[%]
Spot Ø at
max. range
[mm]
Order
no.
Unit of
measurement
Laser
protection class
2
2
Memory plug, parameter memory
for IO-Link sensors
E30398
IO-Link interface, current consumption
from USB port
E30396
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
* at max. range
Hysteresis (example O5D100)
500 1000 1500 20000
0
25
50
75
100
125
150
175
200
y
x
1.
2.
30...2000 ...20 O5D102NPN < 2.5* < 5 cm2
30...2000 ...20 O5D150PNP < 4* < 5 cm1
30...2000 ...20 O5D151PNP < 4* < 5 inch1
x: distance in [mm], y: hysteresis in [mm]
1. Background black (6 % remission)
2. Background white (90 % remission)
22
Position sensors
The next step in
photoelectric sensing
with easy setting
Laser sensors /
distance measurement sensors
Dial switching distance – done!
Reliable background
suppression even at 2 m
Detects any surface finish
or colour
Not fooled by hi-vis
IO-Link adds many options
New improved performance
Time of flight technology as standard sensor
The OID with time of flight technology (PMD = Photonic Mixer Device)
combines the following advantages: long range, reliable background
suppression, visible laser light and high excess gain. In the same price range
as standard sensors, it is a clever alternative.
Easy handling
The switch point can be set easily by turning the setting ring (easy turn).
A scale shows the distance set. The switch point can thus be set before
installation. As an alternative the version without setting ring features the
high protection rating IP69 K.
Any surface and mounting position
Reliable detection of polished, matt, dark or light objects independent
of the colour. The unit allows any angle of incidence and thus flexibility of
mounting. This simplifies installation and saves costs.
23
(11.2016)
For further technical details please visit: www.ifm.com
Photoelectric distance sensor · M12 connector, complementary
30...2000 ...20 PNP < 2* IP 65, IP 67
30...2000 ...20 PNP < 2* IP 65, IP 67 cm / inch
cm
Measuring
range
[mm]
Background
suppression
[m]
Output Hysteresis
[%]
Protection
rating
Order
no.
Unit of
measurement
Laser
protection
class
2
2
30...2000 ...20 PNP < 2*
IP 65, IP 67,
IP 69K
cm / inch2
30...2000 ...20 NPN < 2* IP 65, IP 67 cm2
30...2000 ...20 PNP < 4* IP 65, IP 67 cm / inch1
30...2000 ...20 PNP < 4* IP 65, IP 67 cm1
30...2000 ...20 PNP < 4*
•
•
Setting ring
–
•
•
•
–
IP 65, IP 67,
IP 69K
cm / inch1
Current consumption [mA] < 75
Switching frequency [Hz] 11
Common technical data
Operating voltage [V DC] 10...30
Dimensions M30 x 90 mm
Type of light
visible laser light
650 nm
Spot Ø at max. [mm]
range
< 5
Extraneous light on the object [klx] max. 10
Switching status indication LED yellow
Operation LED green
Short-circuit protection, pulsed •
Reverse polarity /
overload protection
• / •
Ambient temperature [°C] -25...60
Current rating [mA] 2 x 100
Output function
OUT1: NO
OUT2: NC
Material housing
front pane
stainless steel,
PBT, PC, FPM
PMMA
Hysteresis (example OID200)
500 1000 1500 20000
0
25
50
75
100
125
150
175
200
y
x
1.
2.
x: distance in [mm], y: hysteresis in [mm]
1. Background black (6 % remission)
2. Background white (90 % remission)
Connection technology
Type Description Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Type Description Order
no.
Accessories
Angle bracket for type M30,
stainless steel
E10737
Mounting clamp for types M30, PTB E10077
Mounting clamp, with end stop
for types M30, PC
E11049
Memory plug, parameter memory
for IO-Link sensors
E30398
IO-Link interface, current consumption
from USB port
E30396
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
* at max. range
OID201
OID200
OID204
OID202
OID250
OID251
OID254
24
Position sensors
Valve feedback
sensor with
easy wiring
Valve feedback systems for rising stem
valves and quarter-turn actuators
Heavy-duty housing for
long life
Integrated solenoid wiring
Lasered label can be read even
when wet
Clearly visible status indication
Spacious terminal chamber for
easy access
End position feedback on quarter-turn actuators
The unit contains two inductive sensors in a potted and sturdy housing
with protection rating IP 67. It signals two end positions. It is equipped with
a solenoid connection replacing the additional cable to the solenoid valve.
Fast and easy wiring
The actuator interface is optionally equipped with a standardised M20 x 1
gland. The spacious terminal chamber allows quick and easy wiring. Since
the terminal block can be removed, no new wiring is required if the sensor
is replaced.
A UL approval for this product is currently in progress.
25
(11.2016)
For further technical details please visit: www.ifm.com
Ambient
temperature
[°C]
Protection Order
no.
Terminal chamber
20…250 AC/DC -25...70 IP65 / IP67, II IN01312 x M20 x 1.5
Output
function
2 x
normally open
Connection
Sensor / valve
Ub
[V]
Switching frequency [Hz] 25 AC / 50 DC
Sensing range [mm] 4
Electrical design AC/DC
Housing material PA
Minimum load current [mA] 5
Further technical dataDimensions
33
92
6,3
18,8
60
7,5
5,5
30
60
M20x1,5
1) Sensor 1
2) Sensor 2
3) LED OUT 2
4) LED OUT 1
4
6
7
8
5
IN +
IN -
OUT+
OUT-
3
A1
1
2
L1 / L+
A2
2 A
Wiring diagram
Leakage current [mA]
< 2.5 (250 V AC),
< 1.3 (110 V AC),
< 0.8 (24 V DC)
Current rating [mA]
(Duration)
350 AC (...50 °C) /
250 AC (...70 °C) /
100 DC
Current rating [mA]
(In brief)
î: 2.2 A
(20 ms / 0.5 Hz)
Environmental conditions [°C] -25...70
Connection Screw terminals
Accessories
Type Description Order
no.
Plug for covering the oblong holes,
EPDM
E12212
Protective cap, PA 6.6 E12209
Target puck Ø 53 mm E17320
Target puck Ø 102 mm E17328
Spacer for ifm puck, PA E12084
Cable gland, M20 x 1.5, PA 6.6 E12208
26
Position sensors
Feedback for hand
valves
Valves sensors, accessories
Suitable for ISO top flange
valves from F04 to F10
Easy installation on manual
valves and ball valves
Height-adjustable for
flexibility
Stainless steel components
for long life
Ideal for hazardous areas
End position feedback for manual valves and ball valves
With this mounting kit, you can very easily equip your manual valves with
sensors and target pucks. A large number of sensors and pucks can be
used on the 80 x 30 mm actuator interface to VDI/VDE 3845. The entire
system can be used at ambient temperatures from -30 to +80 °C.
Versatile and flexible
The upper part is made out of Vestamid and allows operation in hazardous
areas. The lower part fits on many ISO flange valves (DIN EN ISO 5211) and
is connected to the valve shaft by a shaft extension.
Stainless steel components guarantee increased service life.
27
(11.2016)
E12520
(F05/M5)/
E12521
(F05/M6)
E12524
(F10/M8)
Order no.
E12522
(F07/M6)/
E12523
(F07/M8)
E12519
(F04/M5)
Accessories
Type Description Order
no.
Inductive sensor, PBT,
M12 connector
IN5327
Target puck Ø 53 mm,
PA 6, V2A (1.4302)
E17320
Plug for covering the oblong holes,
EPDM
E12212
NN5008
For further technical details please visit: www.ifm.com
20.70A
B
C
D
H1
H2
20
60
54
D4
D5
42
5.3
60
70
H3
H4
80
90
H5 100
24.36
15
60
54
50
6.5
60
70
80
90
100
34.50
15
65
54
70
8.5
60
70
80
90
100
52.12
15
93
74
102
11
80
90
100
110
120
Dimensions
Connection technology
Type Description Order
no.
Socket, M12,
5 m orange, PVC cable
EVT001
Socket, M12, ATEX approval
5 m, blue, PUR cable
ENC02A
Switching amplifiers
for Namur sensors, 2 channels
N0532A
AS-i sensor,
M12 connector
AC2315
NAMUR sensor (1D,1G, 2G),
M12 connector
15
C
4
4,8
25
5
620
12H1
H2
H3
H4
H5
A
D
B
13
4,8
D5
12
4
60
4
M
D4
28
Sensors for motion control
Intelligent
incremental encoder
with display and
IO-Link
Encoders
Resolution of 2...10,000 and
signal level (TTL / HTL) freely
programmable
Display:
Two-colour electronic rotatable
display of the process values
Versatile: M12 connector can
be used radially or axially
Standard fitting: Solid shaft
(clamp / synchro flange)
or hollow shaft design
Motion controller: Encoder, speed/direction monitor
and counter all in one
The magnetic sensing principle provides the accuracy of photoelectric
encoders and the robustness of magnetic systems.
Resolution and signal level can be programmed. The encoders have a wide
voltage range of 4.75...30 V DC and are therefore suited for universal use.
Performance Line encoders have an integrated signal evaluation for speed
monitoring, counter functions and detection of the direction of rotation.
They provide easy setting, position indication by means of display and
operating keys and intuitive menu navigation.
Diagnostic and parameter data are reliably transferred via IO-Link.
Ready for Industry 4.0.
29
(04.2016)
For further technical details please visit: www.ifm.com
Flange IO-LinkResolution
[pulse/revolution]
Order
no.
Hollow shaft with integrated stator coupling· 4-digit display · Integrated pulse evaluation
direct •max. 10,000 (adjustable) ROP52012
Operating voltage
[V DC]
4.75...30
Shaft Ø
[mm]
Solid shaft · 4-digit display · Integrated pulse evaluation
synchro •max. 10,000 (adjustable) RUP5006 4.75...30
clamp flange •max. 10,000 (adjustable) RVP51010 4.75...30
Protection IP 65, IP 67
Connection
M12 connector
(rotatable)
Further technical data
58
58
58
Housing Ø
[mm]
Switching frequency [kHz] 1000
Accessories
Type Description Order
no.
Spring disc coupling,
Ø 6 mm / 10 mm, die-cast zinc; PA
E60117
Spring disc coupling,
Ø 10 mm / 10 mm, die-cast zinc; PA
E60118
Flexible coupling with clamp connection,
Ø 6 mm / 10 mm, aluminium
E60066
Flexible coupling with clamp connection,
Ø 10 mm / 10 mm, aluminium
E60067
Flexible coupling with adjusting screws,
Ø 10 mm / 10 mm, aluminium
E60022
Flexible coupling with adjusting screws,
Ø 6 mm / 10 mm, aluminium
E60028
Measuring wheel,
Ø 159.15 mm / 10 mm, Hytrel TPE-E
E60110
Measuring wheel,
Ø 159.16 mm / 10 mm, aluminium, PU
E60076
Measuring wheel,
Ø 63.66 ± 0.1 mm / 10 mm, Hytrel TPE-E
E60138
Measuring wheel,
Ø 63.6 mm, 10 mm, aluminium
E60095
Measuring wheel,
Ø 63.66 ± 0.1 mm / 6 mm, aluminium
E60137
Measuring wheel,
Ø 63.6 mm, 6 mm, aluminium
E60006
Angle bracket for RUP design,
aluminium, black anodised
E60033
Angle bracket for RUP design,
aluminium, black anodised
E60035
Fastening clamp for
synchro flange, steel
E60041
Memory plug, parameter memory
for IO-Link sensors
E30398
LINERECORDER SENSOR,
Software for parameter setting and
set-up of IO-Link sensors
QA0001
Accessories
Type Description Order
no.
Connection technology
Type Description Order
no.
M12 socket, shielded,
5 m black, PUR cable, 8 poles
E12403
M12 socket, shielded,
10 m black, PUR cable, 8 poles
E12404
M12 socket, shielded,
2 m black, PUR cable, 8 poles
E12402
USB IO-Link master for parameter setting
and analysis of units
Supported communication protocols:
IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Adapter cable for the connection
between USB IO-Link master E30390
and 3-pole / 8-pole encoder
E12432
Flexible coupling with clamp connection,
Ø 6 mm / 1/4", aluminium
E60206
Flexible coupling with clamp connection,
Ø 6 mm / 3/8", aluminium
E60207
Flexible coupling with clamp connection,
Ø 10 mm / 1/2", aluminium
E60208
Flexible coupling with clamp connection,
Ø 10 mm / 3/8", aluminium
E60209
Connection cable,
M23 plug / M12 socket,
PUR cable, shielded,
0.3 m black, 8 poles
E12460
30
Sensors for motion control
Robust speed
sensors – also with
ATEX approval
Speed sensors
Robust M30 metal housing,
no additional impact protection
housing required
Ideal in combination with
a PLC
Flush installation
Flexible voltage supply:
(20...250 AC/DC)
ATEX approval group II,
category 3D
Compact speed monitoring
The new speed sensors are the compact solution for speed monitoring
because the evaluation electronics are integrated in the sensor housing.
The limit at the speed of which the output switches is set via a potentio-
meter. Both rotary and linear movements can be monitored for overspeed,
underspeed and blockage.
As compared to its predecessors, these new sensors feature a robust
metal housing for flush mounting. A special version with ATEX approval is
available for which no additional impact protection is required.
31
(04.2016)
For further technical details please visit: www.ifm.com
Operating voltage
[V]
Start-up-delay
[s]
Ambient
temperature
[°C]
ATEX approvalMax. load current
[mA]
Order
no.
M30 x 1.5 inductive sensor · connection cable
20...250 AC/DC
(45...65 Hz, AC)
12 -25...80 –
350 AC (50 °C),
250 AC / 100 DC (80 °C)
DI0101
20...250 AC/DC
(45...65 Hz, AC)
< 0.5 -25...80 –
350 AC (50 °C),
250 AC / 100 DC (80 °C)
DI0104
20...250 AC/DC
(45...65 Hz, AC)
12 -20...60
Group II,
category 3D
200 AC / 100 DC
(60 °C)
DI103A
Further technical data
Setting range [pulses/min] 5...3600
Switch point setting
Multiturn
potentiometer
Switching status indication LED 2 x yellow
Housing materials
Brass
special coating;
PA (Polyamid); TPE-U
Connection PUR cable, 2m
Protection rating IP 65, IP 67
Protection class II
Accessories
Type Description Order
no.
Applications
Especially in the field of conveying technology the
compact speed sensors can be used for various applica-
tions, for example for monitoring belt conveyors or
bucket elevators. Here they are typically used to monitor
underspeed, blockage or standstill.
Advantages
The speed sensors incorporate the complete speed
monitoring because the evaluation electronics and the
sensor are integrated in one housing. The switch point
is set using a multi-turn potentiometer. Hysteresis and
start-up delay are firmly set.
Operation
The integrated sensor is damped by passing cams or
other metallic targets. On the basis of the time interval
between damping the evaluation unit determines the
period duration or the frequency (actual rotational
speed value) and compares it to the set switch point
(preset value).
The output is switched during the start-up delay and
when the rotational speed exceeds the set switching
value.
An LED signals underspeed and switch-off of the
output.
Dimensions
80
75,5
M30x1,5
5,4
2,2
36
5
1
LEDs
1) potentiometer
WH
BK
L1
L+
L
N
Wiring
Target wheel E89010
Mounting clamp with end stop for
M30 types
E11049
Fixing clamp with reducing bush for
M30 types
E10077
Angle bracket for M30 types E10737
Lock nuts, nickel-plated brass E10030
Lock nuts, high-grade stainless steel
(316Ti/1.4571)
E10031
Mounting set, free-standing M12
clamp mounting, Ø 30.2 mm
E20873
Mounting set, aluminium profile
clamp mounting, Ø 30.2 mm
E20875
Clamp with damping cams E89013
32
Sensors for motion control
Decentralised display,
preprocessing
and conversion of
analogue signals
Pulse evaluation systems
Mini display to monitor values
Clearly visible display with
red/green colour change
Compact design with
protection rating IP 67
Parameter setting via IO-Link
Conversion of analogue
measured values to an IO-Link
communication
Analogue signals at a glance
The compact connector unit is simply inserted in the connection cable of
analogue sensors (4...20 mA). It displays the measured values locally. The
user can set a switch point or limit at which the transistor output switches.
A colour change (red/green) of the display indicates this unmistakably.
Critical process states or operational problems are reliably signalled.
Converter for Industry 4.0
A special feature is the signal conversion: The threshold display converts
analogue signals to digital IO-Link signals. Today they are required in almost
any modern industrial environment and for Industry 4.0 applications.
33
(11.2016)
Threshold display
DP2200
Dimensions
31
24
3
30
M12x1
M12x1
63
1
2
1) Push ring
2) LEDs
3) Display
Wiring diagram
43
2 1
3
1 2
4
5
M12: plug
Pin 1: L+ supply
Pin 2: OUT2 analogue output
Pin 3: L- supply
Pin 4: OUT1 switching output 1 or IO-Link
M12: Buchse
Pin 1: L+ sensor supply
Pin 2: 4...20 mA analogue input
Pin 3: L- sensor supply
Pin 4: not used
Pin 5: not used
Typical plant configuration
sensor parameter setting
LINERECORDER
sensor 4.0
IO-Link
Threshold
display
with
IO-Link
USB
adapter
PLC
4...20 mA
4...20 mA
industrial fieldbus
4...20 mA
IO-Link master
IP67
PLC
industrial fieldbus
IO-Link
sensors
without
IO-Link
···1 7 8
M
without
IO-Link
Operating voltage [V DC] 27 (typ. 24)
Inputs
1 x analogue,
4...20 mA
Ambient temperature [°C] -25...70
Protection IP 67
Output status indication LED yellow
Operation LED green
Wiring M12 connector
Outputs
1 x digital / IO-Link,
normaly open / closed
programmable
1 x analogue, 4...20 mA
Display
7-segment LED display
4-digit
red/green
programmable
Technical data
For further technical details please visit: www.ifm.com
Accessories
Type Description Order
no.
Mounting clip E89208
LINERECORDER SENSOR,
Software for parameter setting and
setting up IO-Link sensors
QA0001
USB IO-Link master for parameter setting
and analysis of units
Supported communication protocols:
IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
34
Sensors for motion control
Multifunctional
display:
speed, time, counter
Systems for pulse evaluation
Clearly legible display
4 switching outputs and / or
analogue output (V or mA)
250 kHz input frequency
PNP, NPN or NAMUR inputs
Touch display and clear text
for intuitive handling
Versatile pulse evaluation
The multifunction display shows various measured values in industrial
automation. It uses the principle of interval measurement to processes
input pulses. The scaling factor allows (rotational) speed and processing
time, etc., to be calculated, displayed and converted into an analogue
signal. The unit can also act as a counter or an industrial timer.
High performance
Five different operating modes, optional analogue and switching outputs as
well as the convenient display make the multifunctional evaluation system
fit for various applications in industrial automation.
35
(11.2016)
For further technical details please visit: www.ifm.com
Dimensions
Operating voltage
[V]
Inputs Inputs
programmable
Outputs
Transistor
Outputs
Relay
Order
no.
Multifunction display · touch display and clear text
24 DC 2 3 –– DX2031
24 DC 2 3 4V or mA DX2032
24 DC 2 3 4– DX2033
Operating voltage [V DC] 18...30
Current consumption [mA] approx. 150 (without load)
Sensor supply [V DC]
Output current
UB -1 V
max. 250 mA
Incremental inputs
Usage
Format
Frequency
PNP, NPN, Namur encoders
and sensors
HTL (10...30 V)
max. 250 kHz
Control inputs Format
Frequency
HTL, PNP (10...30 V)
max. 250 kHz
Analogue output
(only DX2032) Voltage output
Current output
Resolution
Accuracy
-10...10 V / 0...10 V
0...20 mA / 4...20 mA
16 bits
± 0.1 %
Control outputs
(DX2032 / DX2033) Format / level
Output current
3...30 V (depending on the
voltage on Com+), PNP
max. 250 mA (max. 150
mA at Com+ <10 V)
Display Type
Colour
Handling
LCD (backlight)
red, green, yellow
(selectable)
Touch screen (resistive)
Ambient temperature [°C] -20...60
Dimensions (W x H x D) [mm] 96 x 48 x 100
Common technical data
48
96,2 115,3
114
36
Industrial imaging
Augmented reality:
mobile 3D smart
camera with overlay
function
Camera systems for
mobile machines
3D sensor system with inte-
grated 2D camera and overlay
function
Indication of warnings and
obstacles in the live view
Signal processing in the
sensor, no external process
unit required
Easy adjustment via
ifm Vision Assistant
Augmented reality
The 3D smart camera is the first 3D sensor system with integrated 2D camera.
The video image is displayed with real-time graphics, symbols or texts.
They are either triggered by the integrated driver assistance system or by
the machine controller via CAN. Thus, the user can always see all relevant
warnings or other relevant details in the camera image.
Integrated assistance system
In addition to the 3D and 2D image sensor a complete evaluation system
is integrated in the sensor system. This system provides an independent
assistance system for collision avoidance for the user. Set-up only requires
just a few steps using the ifm Vision Assistant PC software. In addition to
the analogue video output the smart camera also features a CAN and
Ethernet UDP interface. The system can use this interface to supply warnings
in critical situations autonomously.
37
(11.2016)
For further technical details please visit: www.ifm.com
Further technical data
O3M251
Housing material diecast aluminium
PAL resolution [pixels] 640 x 480
Type of sensor
1/4" 4:3 VGA CMOS
image sensor Color
Connection M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage [V DC] 9...32
Current consumption sensor [mA] < 500
Current consumption [A]
system illumination unit
< 5
Ambient temperature [°C] -40...85
Interfaces
1x CAN,
1 x fast Ethernet,
1x PAL
Storage temperature -40...105
Supported CAN protocols
CANopen,
SAE J 1939
Standards and tests
(extract)
CE,
E1 (UN-ECE R10)
Resolution
[pixels]
Angle of aperture
horizontal x vertical
[°]
IlluminationAngle of aperture
2D
[°]
Order
no.
PMD 3D sensor · Type O3M · M12 connector
64 x 16 70 x 23
Ext. illumination
required (O3M950)
90 O3M251
Max.
sampling rate
[Hz]
25/33/50
Accessories
Type Description Order
no.
IR system illumination unit (850 nm)
for mobile 3D sensors,
angle of aperture 70 x 23
O3M950
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped bracket,
suitable for sensor or illumination
E3M100
Weather protective cover
(the article E3M100 or E3M102
is required for installation)
E3M101
U-shaped bracket,
suitable for sensor or illumination unit
E3M102
Connection technology
Type Description Order
no.
MCI cable, connection
sensor / system illumination unit, 0,25 m
E3M120
MCI cable, connection
sensor / system illumination unit, 1 m
E3M121
MCI cable, connection
sensor / system illumination unit, 2 m
E3M122
MCI cable, connection
sensor / system illumination unit, 3 m
E3M123
M12 video connection cable, connection
sensor / display PDM360, 5 m
E3M151
M12 video connection cable, connection
sensor / display PDM360, 11 m
E3M152
M12 video connection cable, connection
sensor / display PDM360, 16 m
E3M153
M12 video connection cable, connection
sensor / display PDM360, 21 m
E3M154
M12 socket, voltage supply system
illumination unit, 2 m,
PUR cable, 4 poles
E3M131
M12 socket, voltage supply system
illumination unit, 5 m,
PUR cable, 4 poles
E3M132
M12 socket, voltage supply system
illumination unit, 10 m,
PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,
2 m, PVC cable, M12 / RJ45
E11898
Ethernet, cross-over patch cable,
10 m, PVC cable, M12 / RJ45
E12204
Ethernet, cross-over patch cable,
20 m, PVC cable, M12 / RJ45
E12205
CAN jumper,
screened, 2 m, PUR cable,
M12 plug / M12 socket
E11593
CAN jumper,
screened, 5 m, PUR cable,
M12 plug / M12 socket
E11594
CAN jumper,
screened, 10 m, PUR cable,
M12 plug / M12 socket
E11595
M12 video extension cable, 5 m E3M159
M12 video adapter cable / Cinch plug,
for connection of a video grabber, 1 m
E3M160
38
Industrial imaging
Mobile 3D camera –
2D and 3D in one
unit
Camera systems for
mobile machines
Robust outdoor camera plat-
form for innovative function
development
Synchronous output of 3D
point cloud and live camera
image
Robust raw data, independent
of ambient light and colour
Video output (PAL) and
Ethernet UDP
High shock and vibration
resistance
Two images in one unit
The O3M250 is the first 3D sensor system with integrated 2D camera for
the output of a calibrated video image. In this context, calibrated means
that the 2D image is superimposed on the 3D image.
For external evaluation
The camera system has been designed for system integrators and customers
who intend to use 3D sensor data with their own algorithms in an external
process unit. The image is sent as a PAL video image and the 3D point cloud
is transmitted via Ethernet UDP.
Easy setup
ifm offers the Windows software “ifm Vision Assistant” for setup and
parameter setting.
39
(11.2016)
For further technical details please visit: www.ifm.com
Further technical data
O3M250
Housing material diecast aluminium
PAL resolution [pixels] 640 x 480
Type of sensor
1/4" 4:3 VGA CMOS
image sensor Color
Connection M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage [V DC] 9...32
Current consumption sensor [mA] < 500
Current consumption [A]
system illumination unit
< 5
Ambient temperature [°C] -40...85
Interfaces
1 x fast Ethernet,
1x PAL
Storage temperature [°C] -40...105
Standards and tests
(extract)
CE,
E1 (UN-ECE R10)
Accessories
Connection technology
Type Description Order
no.
Resolution
[pixels]
Angle of aperture
horizontal x vertical
[°]
IlluminationAngle of aperture
2D
[°]
Order
no.
PMD 3D sensor · Type O3M · M12 connector
64 x 16 70 x 23
Ext. illumination
required (O3M950)
90 O3M250
Max.
sampling rate
[Hz]
25/33/50
Type Description Order
no.
IR system illumination unit (850 nm)
for mobile 3D sensors,
angle of aperture 70 x 23
O3M950
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped bracket,
suitable for sensor or illumination
E3M100
MCI cable, connection
sensor / system illumination unit, 0,25 m
E3M120
MCI cable, connection
sensor / system illumination unit, 1 m
E3M121
MCI cable, connection
sensor / system illumination unit, 2 m
E3M122
MCI cable, connection
sensor / system illumination unit, 3 m
E3M123
M12 video connection cable, connection
sensor / display PDM360, 5 m
E3M151
M12 video connection cable, connection
sensor / display PDM360, 11 m
E3M152
M12 video connection cable, connection
sensor / display PDM360, 16 m
E3M153
M12 video connection cable, connection
sensor / display PDM360, 21 m
E3M154
M12 socket, voltage supply system
illumination unit, 2 m,
PUR cable, 4 poles
E3M131
M12 socket, voltage supply system
illumination unit, 5 m,
PUR cable, 4 poles
E3M132
M12 socket, voltage supply system
illumination unit, 10 m,
PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,
2 m, PVC cable, M12 / RJ45
E11898
Ethernet, cross-over patch cable,
10 m, PVC cable, M12 / RJ45
E12204
Ethernet, cross-over patch cable,
20 m, PVC cable, M12 / RJ45
E12205
CAN jumper,
screened, 2 m, PUR cable,
M12 plug / M12 socket
E11593
CAN jumper,
screened, 5 m, PUR cable,
M12 plug / M12 socket
E11594
CAN jumper,
screened, 10 m, PUR cable,
M12 plug / M12 socket
E11595
M12 video extension cable, 5 m E3M159
M12 video adapter cable / Cinch plug,
for connection of a video grabber, 1 m
E3M160
Weather protective cover
(the article E3M100 or E3M102
is required for installation)
E3M101
U-shaped bracket,
suitable for sensor or illumination unit
E3M102
40
Industrial imaging
True 3D vision sensor
with intelligent
functions
Camera systems for
mobile machines
Simple application solutions
thanks to preprocessed 3D data
Easy integration via predefined
CODESYS function blocks
Patented pmd time-of-flight
technology for quick distance
detection
Optimised for reliable outdoor
use with IP 67 and IP 69K
Angle of aperture up to 95°
Mobile 3D smart sensors O3M
The 3D detection of scenes and objects, already a standard on the factory
floor, is ready for mobile machines. Apart from new possibilities for vehicle
automation (AGV, automatic guided vehicles) this results in new assistance
functions for automation tasks.
Different integrated functions configurable via the Windows software are
available as standard.
The simple connection of the 3D smart sensors is carried out via the CAN bus
for mobile applications using the CANopen or SAE J 1939 protocol and/or
via the fast Ethernet interface using UDP.
41
(04.2016)
For further technical details please visit: www.ifm.com
Description Order
no.
IR system illumination unit (850 nm) for mobile
3D sensors, angle of aperture 70 x 23
O3M950
IR system illumination unit (850 nm) for mobile
3D sensors, angle of aperture 95 x 32
O3M960
Further technical data
Smart sensors O3M151, O3M161
Accessories
Housing material diecast aluminium
Device connection M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage [V DC] 9...32
Functions and advantages
Powerful 3D time-of-flight measurement (ToF)
The principle of these 3D sensors is based on ifm’s
patented and award-winning pmd technology.
It was specifically designed for outdoor use and difficult
ambient light situations. Even interference such as sun-
light or materials with different reflective characteristics
do not influence the repeatability of the measured data.
Powerful electronics
The integrated 2 x 32-bit processor architecture ensures
a rapid and reliable calculation of the 3D data and
functions directly integrated in the system with up to
50 fps. The complete electronics of the mobile 3D smart
sensor is optimised and adapted to the demands and
requirements of mobile machines.
Besides shock and vibration resistance self-diagnostic
functions from the sensor to the IR system illumination
unit are of course also available.
Smart functions
The mobile 3D smart sensors integrate some functions
which enable a multitude of applications to be solved.
A highly developed algorithm from the automotive
industry is used ensuring, for example, reliable automatic
object recognition of up to 20 objects. This function
can, for example, be used as collision warning.
For simple distance tasks typical functions such as
minimum / maximum / average distance are available.
System parameter setting and monitoring
The parameter setting of the system and live monitoring
of the 3D data are carried out via the easy-to-use ifm
vision wizard for Windows. As an alternative, parameter
setting can also be carried out via function blocks using
the software CODESYS.
Communication interfaces
The preprocessed function data is output via the CAN
bus using CANopen or SAE J 1939. If needed, the
complete 3D information can be processed at the same
time via Ethernet UDP and an external process unit.
Current consumption sensor [mA] < 400
Current consumption [A]
system illumination unit
< 5
Ambient temperature [°C] -40...85
Interfaces
1x CAN,
1 x fast Ethernet
Supported CAN protocols CANopen, SAE J 1939
Standards and tests
(extract)
CE,
E1 (UN-ECE R10)
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped holder,
suitable for sensor or illumination unit
E3M100
Connection technology
MCI cable, connection
sensor / system illumination unit, 1 m
E3M121
MCI cable, connection
sensor / system illumination unit, 2 m
E3M122
Type Description Order
no.
M12 socket, voltage supply system
illumination unit, 2 m,
PUR cable, 4 poles
E3M131
M12 socket, voltage supply system
illumination unit, 10 m,
PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,
2 m, PVC cable, M12 / RJ45
E11898
Ethernet, cross-over patch cable,
10 m, PVC cable, M12 / RJ45
E12204
Type of sensor Resolution
pixels
[pixel]
IlluminationAngle of aperture
horizontal x vertical
[°]
Order
no.
PMD 3D sensor · Type O3M · M12 connector
PMD 3D chip 64 x 16
ext. illumination
required (O3M950)
70 x 23 O3M151
Max.
sampling rate
[Hz]
25/33/50
PMD 3D chip 64 x 16
ext. illumination
required (O3M960)
95 x 32 O3M16125/33/50
42
Industrial imaging
3D sensors for
mobile machines
Camera systems for
mobile machines
Support for system
integrators with data output
via Ethernet UDP
Patented pmd time-of-flight
technology for quick distance
detection
Optimised for reliable
outdoor use
Robust design with IP 67
and IP 69K
Angle of aperture up to 95°
Mobile 3D sensors O3M
The 3D detection of scenes and objects, already a standard on the factory
floor, is ready for mobile machines. Apart from new possibilities for vehicle
automation (AGV, automatic guided vehicles) this results in new assistance
functions for automation tasks.
Besides position data at pixel level the respective distance to the sensor
system or an adjustable reference point (world coordinate system) is
provided. Thanks to the permanent output of the entire 3D information
via Ethernet UDP optimum conditions for customer-specific application
solutions are provided to system integrators.
43
(04.2016)
For further technical details please visit: www.ifm.com
Further technical data
O3M150, O3M160
Housing material diecast aluminium
Device connection M12 connector
Protection rating,
protection class
IP 67 / IP 69K,
III
Operating voltage [V DC] 9...32
Functions and advantages
Powerful 3D time-of-flight measurement (ToF)
The principle of these 3D sensors is based on ifm’s
patented and award-winning pmd technology.
It was specifically designed for outdoor use and difficult
ambient light situations. Interference such as sunlight
or materials with different reflective characteristics
which occurs in the area of mobile machines does not
influence the repeatability of the measured data.
Powerful electronics
The integrated 2 x 32-bit processor architecture ensures
a rapid and reliable calculation of the distance image to
be output with up to 50 fps. The complete electronics
of the mobile 3D sensor is optimised and adapted to the
demands and requirements of mobile machines.
Besides shock and vibration resistance self-diagnostic
functions from the sensor to the IR system illumination
unit are of course also available.
High system uptime
The system has various features to ensure uninterrupted
operation. They include, among others, soiling indication
as well as different status information which can be
fetched from CAN.
System parameter setting and monitoring
The parameter setting of the system and live monitoring
of the 3D data are carried out via the easy-to-use ifm
vision wizard for Windows.
Communication interfaces
The mobile 3D sensors feature a fast Ethernet interface
(100 Mbit) as well as a CAN interface. The data output
of the complete 3D information is carried out via
Ethernet UDP and can be processed using a process
unit at the customer’s end. For this version the CAN in-
terface is only intended for parameter setting and
status output.
Current consumption sensor [mA] < 400
Current consumption [A]
system illumination unit
< 5
Ambient temperature [°C] -40...85
Interfaces
1x CAN,
1 x fast Ethernet
Connection technology
MCI cable, connection
sensor / system illumination unit, 1 m
E3M121
MCI cable, connection
sensor / system illumination unit, 2 m
E3M122
Type Description Order
no.
M12 socket, voltage supply system
illumination unit, 2 m,
PUR cable, 4 poles
E3M131
M12 socket, voltage supply system
illumination unit, 10 m,
PUR cable, 4 poles
E3M133
Ethernet, cross-over patch cable,
2 m, PVC cable, M12 / RJ45
E11898
Ethernet, cross-over patch cable,
10 m, PVC cable, M12 / RJ45
E12204
Type of sensor Resolution
pixels
[pixel]
IlluminationAngle of aperture
horizontal x vertical
[°]
Order
no.
PMD 3D sensor · Type O3M · M12 connector
PMD 3D chip 64 x 16
ext. illumination
required (O3M950)
70 x 23 O3M150
Max.
sampling rate
[Hz]
25/33/50
PMD 3D chip 64 x 16
ext. illumination
required (O3M960)
95 x 32 O3M16025/33/50
Description Order
no.
IR system illumination unit (850 nm) for mobile
3D sensors, angle of aperture 70 x 23
O3M950
IR system illumination unit (850 nm) for mobile
3D sensors, angle of aperture 95 x 32
O3M960
Accessories
Supported CAN protocols CANopen, SAE J 1939
Standards and tests
(extract)
CE,
E1 (UN-ECE R10)
CAN/RS232 USB interface CANfox EC2112
Adapter cable set for CANfox EC2114
Operating software for vision sensors E3D300
U-shaped holder,
suitable for sensor or illumination unit
E3M100
44
Industrial imaging
MultiViewBox:
display up to
4 camera images
on one screen
Camera systems for
mobile machines
Video splitter for up to four
camera images
9 different display modes
(incl. bird’s eye view)
Analogue video output (PAL)
Shock and vibration resistant,
potted stainless steel housing
E4 type approval, optimised
for use in mobile machines
Suitable camera images in every situation
The multi-view box has been designed for use in mobile machines in harsh
environments. It features four camera inputs. Depending on the require-
ments, 1, 2 or 4 camera images can be selected simultaneously in different
arrangements via one control input. For example: Cam1 when moving for-
wards and Cam2 and 3 when moving backwards. In the “bird’s eye view”
4 camera images can even be combined to become one 360° view. A total
of 9 different display modes are available for the user.
Analogue video output
The ifm PDM360 dialogue module with analogue video input which is also
suitable for mobile use or any other video display with PAL video input can
be used as display.
45
(11.2016)
For further technical details please visit: www.ifm.com
Connection technology
Type Description Order
no.
Connection cable, M16, 3,85 m, 8 poles,
for the voltage supply of the
E2M250 multi-view box, open cable end
E2M251
Socket, M16, wirable
8 poles, for the voltage supply of the
E2M250 multi-view box
E2M252
Adapter cable, 0.6 m black, PUR cable,
M12 connector / M16 socket, to connect
the MultiViewBox to the PDM NG
E2M200
Jumper,
5 m black, PUR cable,
M16 plug / M16 socket
E2M203
Jumper,
11 m black, PUR cable,
M16 plug / M16 socket
E2M204
Jumper,
16 m black, PUR cable,
M16 plug / M16 socket
E2M205
Jumper,
21 m black, PUR cable,
M16 plug / M16 socket
E2M206
Current consumption [mA] < 1200
Video signal
PAL (25 fps,
interlacing)
720H x 576V
(active 680 x 480)
Ambient temperature [°C] -40...85
Protection IP 67 (ISO 20653)
Approval UN-ECE R10
Housing materials
stainless steel
SS316 (1.4401)
Connection M16 connector
MultiViewBox
E2M250
Technical data
Operating voltage [V DC] 10...32 DC
Products
Order
no.
Video splitter,
visualisation of up to 4 camera images
(PAL) on one process and dialogue mo-
dule
E2M250
Type Description
Angle of aperture 78°,
lens heating
O2M200
Angle of aperture 78°, lens heating,
integrated mirror function
O2M201
Angle of aperture 115°,
lens heating
O2M202
Angle of aperture 115°, lens heating,
integrated mirror function
O2M203
MultiViewBox
Analogue camera,
0.5 m connection cable with M16 connector
Dimensions
180
160
113,5
100
73
85
1,5
40
1 2 3 4 5 6
1) INPUT
2) OUTPUT
3) C4
4) C3
5) C2
6) C1
46
Industrial imaging
Photoelectric 3D
level measurement
and point level
detection
3D sensors
Continuous measurement of
uneven surfaces
Determines min, max or mean
values
Teaching of different tank
shapes
Interfering structures are
suppressed
Non-contact detection of
opaque media for levels of
up to 10 m
Flexible configuration
The system detects solid, opaque solids and bulk materials in tanks, silos or
hoppers with levels of up to 10 m. The O3D reliably detects the load height
in machinery for mechanical handling, e.g. belts, and the loading of pallets.
The sensor determines the level via a defined background and transmits the
process value via analogue output or digitally and noise immune via the
Ethernet process interface. Alternatively, the O3D may be used as a point
level switch.
The measuring segment of the sensor can be adapted to the shape of the
respective tank. Agitators and other attachments can be suppressed via
“exclusion regions”. Various container shapes, such as hoppers, silos or
even inclined belts can be recognised by the sensor.
This means that for bulk materials the average level is indicated, even if
there are conical heaps or funnelling.
47
(11.2016)
For further technical details please visit: www.ifm.com
Mounting set for O3D E3D301
Further technical data
Accessories
Operating voltage [V DC] 20.4...28.8
Current consumption [mA]
< 2400 peak current
pulsed;
typ. mean value
420
Current rating [mA]
(per switching output)
100
Real chip resolution
25,000 /
100,000
Resulting resolution
176 x 132
pixels
Function display LED
2 x yellow,
2 x green
Illumination
850 nm,
infrared
Ambient light [lux]
max. 10,000
(indoor)
Trigger
external;
24 V PNP / NPN
according to
IEC 61131-2 type 3
Switching inputs
2
(configurable),
24 V PNP/NPN
according to
IEC 61131-2 type 3
Switching outputs
digital
3
(configurable),
24 V PNP/NPN,
according to
IEC 61131-2
Switching outputs
analogue
1
(can be configured as
current output 4...20 mA
or voltage
output 0...10 V)
Ambient temperature [°C] -10...50
Ethernet, cross-over patch cable,
2 m, PVC cable, M12 / RJ45
E11898
Ethernet, jumper cables,
2 m, PVC cable, M12 / M12
E21138
Type of sensor Material
front pane /
LED window
Angle of
aperture
[°]
Protection rating,
protection class
Order
no.
PMD 3D sensors · Type O3D · M12 connector
PMD 3D ToF chip
Gorilla glass /
polyamide
Material
housing
Aluminium 40 x 30
IP 65 / IP 67,
III
O3D300
Max. field
of view size
[m]
2.61 x 3.47
PMD 3D ToF chip
Gorilla glass /
polyamide
Aluminium 60 x 45
IP 65 / IP 67,
III
O3D3023.75 x 5.00
PMD 3D ToF chip
Polycarbonate /
polyamide
Stainless steel 40 x 30
IP 65, IP 67, IP 69K /
III
O3D3102.61 x 3.47
PMD 3D ToF chip
Polycarbonate /
polyamide
Stainless steel 60 x 45
IP 65, IP 67, IP 69K /
III
O3D3123.75 x 5.00
Socket, M12,
2 m black, PUR cable, 8 poles
E11950
Type Description Order
no.
Cooling element E3D302
Double cooling element E3D304
Heat conductor E3D303
Short-circuit protection, pulsed •
Overload protection •
Parameter setting interface
Ethernet
10 Base-T / 100 Base-TX
Possible parameter settings
via PC /
notebook
Dimensions (H, W, D) [mm] 72 x 65 x 85
Technical data
Level measurement and point level detection
Typ. level [m] 0.3...6
Operating distance max. [m] 10
Sampling rate [Hz] 5
Mounting accessories
Connection technology
48
Process sensors
Pressure transmitters
with DEUTSCH, AMP
or M12 connector for
mobile applications
Pressure sensors
Compact design (AF19)
with process connection
G 1/4 male
Fast reaction:
2 milliseconds response time
Measuring accuracy < ± 0.8 %,
repeatability < ± 0.05 %
Easy connection via DEUTSCH,
AMP or M12 connector
Robust low-cost solution with
welded stainless steel housing
Miniaturisation for mobile applications
The connectors of the new PT/PU pressure sensors allow fast and easy
installation in mobile machines.
The sensors also feature a thin-film measuring cell directly welded with the
process connection.
This technology guarantees high accuracy in a very compact housing with
only 19 mm across flats at a cost-optimised price/performance ratio.
Applications
The PT/PU type sensors are suited for mobile applications and especially
for hydraulic and pneumatic applications with high operating pressure.
The high vibration and shock resistance, the high protection rating, the
excellent EMC resistance and the E1 conformity make the PT/PU sensors
particularly suitable for use in mobile machines.
49
(04.2016)
For further technical details please visit: www.ifm.com
Accessories
Type Description Order
no.
Operating voltage PT [V DC]
PU [V DC]
8...32
16...32
Common technical data
Medium temperature [°C] -40...125
Materials wetted parts
1.4542 (17-4 PH / 630),
characteristics similar to
stainless steel
(e.g. 304/1.4301)
but higher strength
Protection IP 67 / IP 69K
Step response time [ms] 2
Restrictor •
EMC
Compliant with UN-ECE10
Rev. 4
ISO 11452: 100 V/m
EN61326
Reverse polarity protection •
Adapters; G 1/4 - G 1/2,
high-grade stainless steel (316Ti/1.4571)
E30135
Accuracy / deviation
(in % of the span)
Linearity error
Linearity
Hysteresis
Repeatability
Long-term stability
Temperature coefficients (TEMPCO)
in the temperature range 0 ... 80 °C
(in % of the span per 10 K)
TEMPCO of zero
TEMPCO of the span
Temperature coefficients (TEMPCO)
in the temperature ranges
-40...0 °C and 80...125 °C
(in % of the span per 10 K)
TEMPCO of zero
TEMPCO of the span
< ± 0.8
< ± 0.25 BFSL / < ± 0.5 LS
< ± 0.2
< ± 0.05
< ± 0.1
< ± 0.1
< ± 0.1
< ± 0.2
< ± 0.2
Wiring diagram
Dimensions
12
65,9
51,6
M12x1
18,9
G
1 4
/
19
1
Example: type PT55
1) HNBR seal / DIN 3869
PU5704
PU5703
PU5702
PU5701
PU5700
PU5760
PU5604
PU5603
PU5602
PU5601
PU5600
PU5660
Measuring range
relative pressure
[bar]
Poverload
max.
[bar]
Pburst
min.
[bar]
Output function 4…20 mA,
0...10 25 300
0...25 65 600
0...100 250 1000 PT5702
0...250 625 1200 PT5701
0...400 1000 1700 PT5700
0...600 1500 2400 PT5760
Output function 0...10 V
0...10 300
0...25 600
0...100 1000
PT5602
0...250 1200
PT5601
0...400 1700
PT5600
0...600 2400
PT5660
PT5502
PT5501
PT5500
PT5560
25
65
250
625
1000
1500
Order
no.
PT5504
M12 connector
PT5503
Order
no.
PT5604
AMP connector
PT5603
Order
no.
PT5704
DEUTSCH connector
M12 connector AMP connector DEUTSCH connector
PT5703
L+
BN1
WH2
OUT
Type PT55
1
2
3
OUT
L +
L -
Type PU56
A
B
OUT
+L
A
C
B
OUT
L -
L +L +
Type PU57Type PT57
1
3
L +
OUT
Type PT56
–
–
–
–
–
–
50
Process sensors
Hydrostatic level
measurement
for a wide range of
applications
Pressure sensors
High-grade stainless steel
submersible pressure transmitter
with PUR or FEP cable for high
resistance to media
Version with ATEX approval
for group I cat. M1 and group II
cat. 1G and 1D.
Good overall accuracy and
long-term stability
Pressure compensation via
internally vented cable
Application areas
The PS series submersible pressure transmitters are used for level
measurement in containers, tanks, wells, flowing water, bore holes and
wastewater plants. The accuracy of 0.5 % and the long-term stability of
0.2 % per year contribute to the reliable operation of the transmitter.
Robust, reliable and flexible
All submersible pressure transmitters have a robust high-grade stainless
steel housing. For standard applications the favourably priced PUR cable
can be used. For applications where a high resistance to media is requested
(e.g. slurry, oils or fuels) the FEP cable is available.
The ATEX submersible pressure transmitters of the PS3xxA series are
designed for level measurement in areas subject to explosion. The sensors
can be used in zone 0, 1, 2 or zone 20, 21, 22 as well as in mining.
The GL approval allows an application in the maritime sector.
51
(04.2016)
For further technical details please visit: www.ifm.com
Splitter box *
with vent and terminal block
E30401
Additional weight, approx. 500 g E30402
Filter element * E30400
Cable fixing clamps * E30399
Submersible pressure transmitters with PUR cable for standard applications
0.6
0.6
0.6
4
4
4
1000 N
1000 N
1000 N
Measuring range
Relative pressure
[bar]
Approvals
CE / EX / GL
Overload pressure
[bar]
Pull force cable
1
1
5
5
1000 N
1000 N
Cable length
[m]
PS3407
PS3427
PS3607
Order
no.
PS3417
PS3617
0.25 2 1000 N
10
15
30
15
30
5
• / – / –
• / – / –
• / – / –
• / – / –
• / – / –
• / – / – PS3208
Operating voltage [V DC] 18...30
Analogue output [mA] 4...20
Accuracy / deviation
(in % of the span)
Accuracy (BFSL)
Accuracy incl. non-linearity
Non-linearity (BFSL)
Long-term stability per year
≤ 0.25 (PS3: 0.5)
≤ 0.5 (PS3: 1)
≤ 0.2
≤ 0.2
Design PS3
Ambient temperature / [°C]
Medium temperature
-10...50
Design PS4
Ambient temperature / [°C]
Medium temperature
-10...85
Design PS3
ATEX approval
Ambient temperature / [°C]
Medium temperature
1G, 1/2G, 2G:
T6 -10...60, T5: -10...80,
T4: -10...85
1D, 1/2D, 2D:
-10...40 (750 mW) / -
10...70 (650 mW) / -
10...85 (550 mW)
Housing material
High-grade stainless steel
(316Ti / 1.4571)
Further technical data
Accessories
Type Description Order
no.
* use only outside the hazardous area
Submersible pressure transmitters with FEP cable for high resistance to media
0.6
1
3
5
500 N
500 N
PS4407
PS4417
0.25 2 500 N
10
15
5
• / – / –
• / – / –
• / – / – PS4208
Submersible pressure transmitters with FEP cable for hazardous areas
0.6
1
4
5
500 N
500 N
PS307A
PS317A
0.25 2 500 N
10
15
5
• / • / •
• / • / •
• / • / • PS308A
Temperature coefficients (TEMPCO)
(in % of the span per 10 K)
Greatest TEMPCO of zero
Greatest TEMPCO of the span
≤ 0.2
≤ 0.2
100
27
Example PS3208
Dimensions
0.6
1
3
5
500 N
500 N
PS4506
PS4607
0.25 2 500 N
20
30
10
• / – / –
• / – / –
• / – / – PS4408
52
Process sensors
New PT absolute
pressure transmitter
with different
measuring ranges
Pressure sensors
Measuring range 0...1/1.6/4/
10 bar absolute and analogue
output 4...20 mA
Robust stainless steel
measuring cell
Slim, compact design with
G 1/4 process connection
Measuring accuracy ≤ 0.8 %,
repeatability ≤ 0.1 %
Easy connection via M12
connector
Absolute pressure sensors
As of now, ifm has added absolute pressure sensors to its versatile portfolio
in the pressure sensor range. The new PT05 series with robust metal
measuring cell, G 1/4 process connection, M12 connector and analogue
output is available in the common pressure ranges up to 10 bar.
Operating principle
Absolute pressure sensors operate independently of the surrounding air
pressure; that is what distinguishes them from sensors working on a relative
measurement principle. The measurement is not influenced by weather-
and altitude-related fluctuations of air pressure. This is often a decisive factor
in vacuum applications, which require a fine pressure control.
Absolute pressure sensors do not require ventilation, therefore incorrect
measurement due to a blocked exhaust is impossible.
In the field of pressure sensors the new units stand out as specialists for
”specific duties“.
53
(04.2016)
For further technical details please visit: www.ifm.com
Accessories
Type Description Order
no.
Operating voltage [V DC] 8...30
Common technical data
Medium temperature [°C] 0...80
Materials (wetted parts)
NBR,
high-grade stainless steel
(316L/1.4404)
Protection IP 67
Step response time [ms] 4
Reverse polarity protection •
Adapter; G 1/4 - G 1/2,
high-grade stainless steel (316Ti/1.4571)
E30135
Measuring range
[bar]
Poverload
max.
[bar]
Pburst
min.
[bar]
Order
no.
Output function 4...20 mA
0...1 5 PT0507
0...1.6 10 PT0517
0...4 25 PT0505
0...10 50 PT0504
Accuracy / deviation
(in % of the span)
Linearity error
Linearity
Repeatability
Temperature error in the
temperature range 0...80 °C
< ± 1.0
< ± 0.5 BFSL / < ± 1.0 LS
< ± 0.1
< ± 2.5 %
Connection technology
Type Description Order
no.
M12 socket,
2 m black, PUR cable
EVC001
M12 socket,
5 m black, PUR cable
EVC002
M12 socket,
2 m black, PUR cable
EVC004
M12 socket,
5 m black, PUR cable
EVC005
L+
BN1
WH2
OUT
Wiring diagram
Dimensions
14
47
58,8
G¼
29
M12x1
27
1
1) Sealing
2
3.2
8
20
54
Process sensors
IO-Link display:
process values at
a glance
IO-Link display
Four measured values / text
displays and four message
windows for free text
Colour change for text and
background
Flexible adaptation of the
display, also during operation
IO-Link 1.1 compatible
Easy integration into each
IO-Link structure
More plant transparency
The IO-Link display is a flexible solution to display process values, texts
and messages in a plant. It displays up to four assigned process values,
alarms and warnings. Clear text and as an option a colour change of text
and background can be used for a quick overview.
By means of buttons the user can trigger control actions of the PLC or
acknowledge messages.
Easy integration
The IO-Link display is connected to an IO-Link master and controlled via
PLC. No special software is required for configuration.
Texts and settings can be predetermined via an IO-Link device tool such as
LINERECORDER SENSOR. Texts and settings can be adapted even during
operation via the PLC.
55
(04.2016)
For further technical details please visit: www.ifm.com
Resolution
pixels
Display type Display
illumination
Order
no.
1.44" colour display
128 x 128 TFT LED E30391
Wiring
Dimensions
Technical data
IO-Link display
E30391
Operating voltage [V DC] 18...30
Current consumption [mA] < 47
Protection rating /
protection class
IP 65, IP 67 /
III
Reverse polarity protection •
Ambient temperature [°C] 0...60
EMC
EN 61000-6-2
EN 61000-6-4
Shock resistance [g] 20 (11 ms)
Vibration resistance [g] 20 (10...50 Hz)
Housing materials
Stainless steel
(303/1.4305);
PC; PBT-GF 30;
PPS; PA 6.6; FKM
Connection M12 connector
Communication interface
IO-Link device
Type of transmission
IO-Link revision
SDCI standard
COM2 (38.4 kbaud)
1.1
IEC 61131-9
Connection technology
Type Description Order
no.
M12 jumper
1 m black, PUR cable
EVC042
M12 jumper
2 m black, PUR cable
EVC043
M12 jumper,
3 m black, PUR cable
EVC102
M12 jumper,
5 m black, PUR cable
EVC044
M12 jumper,
10 m black, PUR cable
EVC493
BN1
BK4
BU3
L+
L
OUT
45
34
86
101
39,5
11
M12x1
Accessories
Type Description Order
no.
DIN rail clip,
PA; 1.4567 (V2A)
E30429
56
Process sensors
Calorimetric flow
meter for liquids
and gases
Flow sensors / flow meters
Optimised for water, oils,
glycol and air
Fast response time and
integrated temperature
measurement
Red/green colour change for
process values
Internal pipe diameter selectable
from 15...400 mm
The process connection can be
rotated for optimum alignment
Measurement technique
The SA volumetric flow sensor operates using the calorimetric measuring
principle. Measuring elements as well as a heat source are located on the
measuring tip. The physical effect that a flowing medium absorbs heat
energy and conducts it away is used. The resulting temperature change is
an indication of flow.
Device function
The new SA-type sensor has been designed to detect and measure flow
and temperature even in large internal pipe diameters up to 400 mm.
A serial number on the device enables unambiguous traceability.
Therefore it serves different applications. Switching outputs, analogue
signals and IO-Link provide various options to further process the signals.
That means that the user is best-equipped for Industry 4.0.
57
(04.2016)
For further technical details please visit: www.ifm.com
Common technical data
Operating voltage [V] 18...30 DC
Current consumption [mA] < 100
Current rating [mA] 250
Housing materials
High grade stainless steel
(1.4404/316L);
PBT-GF 20;
PBT-GF 30
Connection M12 connector
Accuracy temperature measurement ± 0.3 K
Type
SA
Protection rating, protection class IP 65 / IP 67, III
BN
WH
BK
BU
4
1
3
2
OUT2
L+
L
OUT1
Wiring
Measuring range
liquid / gaseous
[cm/s]
Medium
temperature
[°C]
Response
time
[s]
Order
no.
M12 connector · electrical design DC PNP
5...300 / 200...10000 -20...90 0.5 SA5000
Probe length
[mm]
45
5...300 / 200...10000 -20...100 0.5 SA4100100
5...300 / 200...10000 -20...100 0.5 SA4300200
Pressure
resistance
[bar]
100
50
50
Type
M18
Progressive ring
Progressive ring
Connection technology
Type Description Order
no.
M12 socket,
2 m black, PUR cable
EVC001
M12 socket,
5 m black, PUR cable
EVC002
M12 socket,
2 m black, PUR cable
EVC004
M12 socket,
5 m black, PUR cable
EVC005
M12 socket,
2 m orange, PVC cable
EVT064
M12 socket,
5 m orange, PVC cable
EVT001
Accuracy flow measurement
± (5 % MW
+ 2 % VMR)
at reference
conditions
Accessories
Type Description Order
no.
Progressive ring fitting G 1/2,
flat seal
E40258
Progressive ring fitting G 1/4,
flat seal
E40259
Progressive ring fitting G 3/4,
flat seal
E40260
USB IO-Link master for parameter setting
and analysis of units
Supported communication protocols:
IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
Progressive ring fitting 1/2 NPT E40261
Progressive ring fitting 1/4 NPT E40262
Progressive ring fitting R 1/2 E40263
Progressive ring fitting R 1/4 E40264
Progressive ring fitting
for SL mounting adapter
E40269
Protective cover for fluid sensors with
M12 connector,
polypropylene homopolymer
E30420
Welding adapter for cutting ring E40265
Flow adapter E40434
Progressive ring fitting G 1/2,
metal to metal seal
E40267
Progressive ring fitting G 3/4
metal to metal seal
E40268
58
Process sensors
Two temperature
sensors in one
Temperature sensors
Two in one: process values
plus two switched outputs
Measuring range
-50...150 °C
IO-Link for simple, remote
setting
Extremely high accuracy
of +/- 0.3 K
Tamper-proof
Flexible in use
The functionality of the temperature sensor TV is impressive. Due to its
extremely compact design the TV sensor can be installed where space is at
a premium. The device has two switch points, operates with an extremely
high precision and can be set easily and quickly via the LINERECORDER
SENSOR.
Efficient and reliable thanks to IO-Link
Thanks to IO-Link the new temperature sensor continuously transmits
process values and other important data, e.g. min. / max. temperature.
Moreover, the digital measurement results are more accurate because there
are no conversion losses by D/A converters or external influences (e.g. cable
lengths). Devices with preset measuring ranges (analogue start and end
points) are no longer needed because the real process value is transmitted.
This reduces stock. Soon conventional transmitters will be a thing of the past.
59
(11.2016)
For further technical details please visit: www.ifm.com
IO-Link interface for parameter setting
and analysis of units with
DTM specification, current consumption
from USB port: max. 500 mA
E30396
Memory plug, parameter memory
for IO-Link sensors
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
IO-Link accessories
Type Description Order
no.
Connection technology
Type Description Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Operating voltage [V DC] 18...32
Protection rating
protection class
IP 69K,
lll
Materials wetted parts
high-grade stainless steel
(316L/1.4404)
Further technical data
Reverse polarity / overload protection • / •
Dynamic response T05 / T09 1 s / 3 s
Accuracy [K] ± 0.3
Measuring range [°C] -50...150
Ambient temperature [°C] -25...80
IO-Link revision 1.1
Dimensions
Wiring diagram
Example TV7105
Example TV7603
Installation
length
[mm]
Order
no.
Pressure rating
[bar]
Output function 2 x NO / NC programmable,
measuring range -50...150 °C
25 400
30 300
25 400
30
Process
connection
G 1/4
G 1/2
1/4" NPT
1/2" NPT 300
TV7105
TV7405
TV7603
TV7303
Example TV7105
6
M12x1
18,7
15,9 48
19
13
G ¼
25
BN
WH
BK
BU
4
1
3
2
OUT2
L+
L
OUT1
6
M12x1
18,7
15,9 48
71
19 ¼" NPT
25
60
Process sensors
Temperature sensor
with easy dial setting
Temperature sensors
Measuring range -25...140 °C
Two switching outputs
Easy adjustment via two setting
rings for optimum read-out
Mechanical lock to prevent
accidental adjustment
Accuracy: ± 3 K
Convenient and reliable setting
The TK type temperature sensors are sensors to monitor liquids and gases
with switch points that can be set intuitively via two radial setting rings.
Wherever simple solutions are needed, the TK series sensors are a real
alternative. Complicated parameter setting via software is not necessary.
The requested temperature is set via the setting rings allowing optimum
read-out without your installation having to be in operation. In addition,
the switching states are clearly displayed via LEDs.
Versions
The sensors are available with a setpoint and a reset point (TK6xxx) or
two switch points with a fixed hysteresis (TK7xxx). The TK series temperature
sensors are always the optimum choice for quick and simple use.
61
(11.2016)
For further technical details please visit: www.ifm.com
Dimensions
M12x1
27
6
G ¼
59
50
12
27LED
Example TK6110
Dynamic response T05 / T09 [s] 1 / 3
Accuracy
Setting accuracy [K]
Temperature influence (per 10 K)
Repeatability [K]
± 3
0.1
± 0.1
Ambient temperature [°C] -40...70
Shock resistance 50 g
Vibration resistance 20 g
Housing materials
high-grade stainless steel
(316L/1.4404),
PC (Makrolon),
PBT (Pocan), FPM (Viton)
Materials wetted parts
high-grade stainless steel
(316L/1.4404),
FPM (Viton)
Connection M12 connector
Protection rating, protection class IP 67 / III
Operating voltage [V DC] 9.6...32
Current rating [mA] 500
Further technical data
Measuring range
[°C / °F]
Order
no.
M12 connector, gold-plated contacts · output function normally open / normally closed complementary
TK6110-25…140 / -13...284
Process connection
G 1/4
Installation length
[mm]
50
Switching hysteresis
[K]
adjustable
Pressure rating
[bar]
400
TK6310-25…140 / -13...284 1/4 NPT 50 adjustable 400
M12 connector, gold-plated contacts · output function 2 x normally open
TK7110-25…140 / -13...284 G 1/4 50 5 (fixed) 400
M12 connector, gold-plated contacts · output function 1 x normally open / 1 x normally closed
TK7460-25…140 / -13...284 G 1/2 250 5 (fixed) 300
Adapter,
G 1/4 – G 1/2
high-grade stainless steel (316Ti/1.4571)
E30135
Protective cover with lead seal option
for TK type temperature sensors,
PP transparent
E30094
Accessories
Type Description Order
no.
Flange adapter G1/4,
stainless steel (303/1.4305)
E30063
Thermowells
G 1/4 E377002750
Screw-in thermowell, process connection G 1/4
G 1/2 E37640224250
Screw-in thermowell, process connection G 1/2
Device connection Installation length [mm]
Sensor Thermowell
Order
no.
Connection technology
Type Description Order
no.
Socket, M12,
2 m black, PUR cable
EVC001
Socket, M12,
5 m black, PUR cable
EVC002
Socket, M12,
2 m black, PUR cable
EVC004
Socket, M12,
5 m black, PUR cable
EVC005
Socket, M12,
2 m black, PUR cable, LED
EVC007
Socket, M12,
5 m black, PUR cable, LED
EVC008
62
Temperature sensors
TN sensor with
integrated process
connection and eva-
luation electronics
Measuring range of -50...150 °C,
response time T05 / T09 = 1s / 3s.
Clearly indicates the acceptable
ranges: programmable
red / green display
Integrated process connections:
G 1/2, G 1/4, 1/2 NPT, 1/4 NPT,
M18 x 1.5
2 switching outputs or
1 switching and 1 analogue
output (4...20 mA or 0...10 V)
Visualisation of the switching
states by clearly visible LEDs
Extremely fast, robust and flexible
The compact TN type temperature sensors are distinguished by excellent
response times, high pressure resistance and integrated process connections.
The sensors easily resist applications with temperatures up to 150 °C and
high pressure loads up to 400 bar. The measuring range is freely scalable.
Updating a classic
What is new is the quick and easy handling via three pushbuttons.
The display can be switched from the indication of ”red“ to an alternating
indication of “red - green“.
So, switching states can be highlighted or an independent colour window
can be created. The sensor head can be rotated and offers optimum
readability from any position. Thanks to captive laser labelling on the
stainless steel housing, the units can still be identified after years.
Process sensors
63
(04.2016)
For further technical details please visit: www.ifm.com
Adapter, M18 x 1.5 - G 1/2
High-grade stainless steel (316L/1.4404)
E40096
Protective cover for fluid sensors with
M12 connector,
polypropylene homopolymer
E30420
Accessories
Type Description Order
no.
Accuracy [K] ± 0.3 + (± 0.1 % MS)
Electrical design PNP / NPN
Protection IP 67
Communication interface IO-Link
Resolution display [K] 0.1
Operating voltage [V] 18...32 DC
Current rating [mA] 250
Further technical data
IO-Link interface for parameter setting
and analysis of units with
DTM specification, current consumption
from USB port: max. 500 mA
E30396
Memory plug, parameter memory
for IO-Link sensors
E30398
LINERECORDER SENSOR,
software for parameter setting and
setting up IO-Link sensors
QA0001
IO-Link accessories
Type Description Order
no.
USB IO-Link master for parameter setting
and analysis of units
Supported communication protocols:
IO-Link (4.8, 38.4 and 230 Kbits/s)
E30390
1) LEDs (display unit / switching status), 2) 4-digit alphanumeric
display / alternating indication of red and green, 3) Programming
buttons, 4) Upper part of the housing can be rotated by 345°
Installation length
[mm]
Pressure resistance
[bar]
300 45
Measuring range
[°C]
Factory setting
[°C]
Order
no.
Output function 1 x NO / NC programmable · 1 x analogue output 4…20 mA or 0…10 V programmable
-50...150 -40...150
Process connection
M18 x 1.5 I TN2511
300 45
Output function 2 x NO / NC programmable
-50...150 -40...150M18 x 1.5 I TN7511
300 30 -50...150G 1/2 TN2405
300 50 -50...150G 1/2 TN2415
160 100 -50...150G 1/2 TN2435
160 150 -50...150G 1/2 TN2445
300 30 -50...1501/2" NPT TN2303
300 50 -50...1501/2" NPT TN2313
160 100 -50...1501/2" NPT TN2333
160 150 -50...1501/2" NPT TN2343
400 25 -50...150G 1/4 TN2105
400 50 -50...150G 1/4 TN2115
400 25 -50...1501/4" NPT TN2603
400 50 -50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...150
-50...1501/4" NPT TN2613
Output function 2 x NO / NC programmable or
1 x NO / NC + 1 x analogue (4...20 mA / 0...10 V; scalable)
Response dynamics T05 / T09 [s] 1 / 3
Thermowell for temperature sensors,
Ø 6 mm,
high-grade stainless steel
(316L/1.4404)
E37610
Dimensions
48
M12x1
22
EL11
41
34
80
121
4
3
2
1
G ¼
6
Example 2105
64
Temperature sensors
Temperature
sensors with
DEUTSCH, AMP or
M12 connector
Miniaturisation for mobile applications
The DEUTSCH, AMP or M12 connectors of the new TA/TU/TM temperature
sensors allow fast and easy installation in mobile machines.
Their extremely compact housing ensures that the sensors are particularly
suited for use in applications where space is limited.
Areas of application
The sensors of type TA/TU/TM are suited for mobile applications and
especially for hydraulic and pneumatic applications with high operating
pressure.
The high vibration and shock resistance, the high protection rating,
the excellent EMC resistance and the E1 conformity make the
TA/TU/TM sensors particularly suitable for use in mobile machines.
Process sensors
Compact design with
G 1/4 process connection
Fast response time:
T05 / T09 = 1 s / 3 s
Installation depths of
25...200 mm
Measuring range -50...150 °C
Robust due to welded stainless
steel housing
65
(04.2016)
For further technical details please visit: www.ifm.com
Installation length
[mm]
Order no.
Factory setting
Connector
G 1/4 process connection
Analogue output 4...20 mA
25 M12
50 M12
200 M12
25 DEUTSCH
G 1/4 process connection
Analogue output 0.5...4.5 V
25 M12
25 DEUTSCH
25 AMP
Operating voltage [V DC]
Type TA
10...30
Operating voltage [V DC]
Type TU
8...32
Protection rating IP 68, IP 69K / lll
Materials in contact
with the medium
High-grade stainless steel
(316L/1.4404)
Further technical data
Reverse polarity / overload protection • / •
Response dynamics T05 / T09 1 s / 3 s
Ambient temperature [°C] -40...100
EMC
DIN EN 61000-6-2
DIN EN 61000-6-3
Dimensions
TA3105
TA3115
TA3155
TA4105
50 DEUTSCH TA4115
25 AMP TA5105
50 AMP TA5115
TU3105
TU4105
TU5105
-50...150 °C
-50...150 °C
G 1/4 process connection
Pt1000, class A
25 M12
25 DEUTSCH
TM5101
TM6101
-40...150 °C
1/4" NPT process connection
Analogue output 4...20 mA
50 M12
50 M12
TA3313
TA3317
0...300 °F /
0...100 °C
Wiring
M12x1
18,8
6
55,3 13
EL
19 G ¼
TA31
21,8
6
25,4
EL
1359,6
19 G ¼
TA41
25,8
6
EL
1359,8
19 G ¼
21,8
TA51
L+
BN1
WH2
OUT
BN1
WH2
BU3
L+
L
OUT
TU31TA31
A
C
B
OUT
L -
L +L +
TU41
1
3
L +
OUT
1
2
3
OUT
L +
L -
TU51TA51
A
B
OUT
+L
TA41
66
Industrial communication
DataLine SmartPLC:
flexible automation
system
AS-Interface controllers / gateways
Quick and easy set-up
Flexible and future-proof
thanks to connective hardware
and CODESYS V3
Various protocols on different
interfaces
Designed for Industry 4.0
applications
Unbeatable price / performance
ratio
Communicative PLC
The DataLine SmartPLC is freely programmable via CODESYS V3 and
offers full access to all interfaces of the system. Two Ethernet ports act
as EtherCAT fieldbus / slave interface and enable high-performance com-
munication to other PLC systems. Different communication protocols can
be used in parallel via two further Ethernet ports, e.g. EtherCAT master,
EtherNet/IP scanner, Modbus TCP master and slave, TCP/IP, UDP/IP or
OPC/UA server.
Designed for Industry 4.0
The DataLine SmartPLC is best-equipped for Industry 4.0 applications.
Towards the PLC, it acts like a classic AS-i gateway and towards IT, any pro-
cess values can be made available via different communication protocols.
An integrated real-time clock and an SD card slot complete the features.
67
(11.2016)
For further technical details please visit: www.ifm.com
Products
Order
no.
SmartSPS DataLine,
1 x AS-i, EtherCAT slave
AC1433
SmartSPS DataLine,
2 x AS-i, EtherCAT slave
AC1434
Dimensions
106,293
135,5
128,2
Example AC1433
Description
DataLine SmartPLC
Advantages and customer benefits
Communication interfaces:
EtherCAT:
Certified EtherCAT functionality
AS-Interface:
1 and 2 AS-i masters pursuant to M4 profile
Configuration interface:
2 Ethernet ports with the following functions:
– Web server
– CODESYS V3 programming interface
– Multifunctional communication interface
(EtherCAT master, Modbus TCP, EtherNet/IP scanner,
OPC/UA server, Web visualisation)
Connections:
– AS-i and auxiliary supply: plug-in terminals
(supplied with the unit)
– EtherCAT 2 x RJ45
– Configuration interface 2x RJ45
Functions
The DataLine SmartPLC supports a number of different
communication protocols via its both configuration
interfaces in order to supply additional input / output
data to the integrated PLC or realise a data exchange
with other units / systems.
For Industry 4.0 applications, there is, amongst others,
an OPC server functionality available that enables an
easy data transfer into your IT world.
68
AS-Interface cable extensions
Repeater to extend
AS-i networks
up to 1000 m
Increased operating
temperature range -25...70 °C
Reliable long term performance
in tough conditions
Fast data transfer for
Safety at Work
Clearly visible diagnostic LEDs
Plug-in connection terminals
Operation
Repeaters are used for AS-Interface to enable the network cable run to be
extended beyond 100 m.
Galvanic separation of network segments and independent voltage supplies
ensure stability. The 62 participants are provided with a higher total current
and the voltage drop decreases.
Features of the unit
The improved performance is packed into the new SmartLine housing.
While conventional repeaters usually have a temperature range from
0...55 °C, the new unit from ifm operates reliably across a broad range
from -25...70 °C.
The improved operating temperature range makes the new unit from ifm
a class leader. This results in a longer life time thus saving time and money.
Industrial communication
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English
Newsbook 2016 / 2017 - English

Más contenido relacionado

La actualidad más candente

Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0
a1-cbiss
 

La actualidad más candente (20)

Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas ApplicationsMagnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
Magnetrol TA2 Thermal Mass Flow Meter for Flare Gas Applications
 
Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Explosive Area. Hubungi PT. Siwali Swantika 021-45850618
 
Fluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection GuideFluke Digital Multimeter Selection Guide
Fluke Digital Multimeter Selection Guide
 
United Electric One Series Safety Transmitter
United Electric One Series Safety TransmitterUnited Electric One Series Safety Transmitter
United Electric One Series Safety Transmitter
 
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
ECD Model T23 pH, ORP, Specific Ion, Dissolved Oxygen, Conduc􏰁tivity Transmit...
 
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CLKT Series. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke 5502A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 5502A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 5502A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 5502A. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke 7380A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 7380A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 7380A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 7380A. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke Hydra Series III. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke 5790B. Hubungi PT. Siwali Swantika 021-45850618
 Datasheet Fluke 5790B. Hubungi PT. Siwali Swantika 021-45850618 Datasheet Fluke 5790B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 5790B. Hubungi PT. Siwali Swantika 021-45850618
 
Watanabe products guide Panel meter signal conditioner
Watanabe products guide  Panel meter signal conditionerWatanabe products guide  Panel meter signal conditioner
Watanabe products guide Panel meter signal conditioner
 
Datasheet Fluke 5080A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 5080A. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke 5080A. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke 5080A. Hubungi PT. Siwali Swantika 021-45850618
 
Datasheet Fluke CV Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CV Series. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke CV Series. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke CV Series. Hubungi PT. Siwali Swantika 021-45850618
 
Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0Wireless olct 80 datasheet 0
Wireless olct 80 datasheet 0
 
United Electric 2018 Short Form Product Catalog
United Electric 2018 Short Form Product CatalogUnited Electric 2018 Short Form Product Catalog
United Electric 2018 Short Form Product Catalog
 
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
Datasheet Fluke A40B. Hubungi PT. Siwali Swantika 021-45850618
 
LLT 100 Continuous, Non-contact, Laser Level Transmitter
LLT 100 Continuous, Non-contact, Laser Level TransmitterLLT 100 Continuous, Non-contact, Laser Level Transmitter
LLT 100 Continuous, Non-contact, Laser Level Transmitter
 
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
Fluke Data Acquisition System Selection Guide. Hubungi PT. Siwali Swantika 02...
 
Hioki data logger selection
Hioki data logger selectionHioki data logger selection
Hioki data logger selection
 
System Sensor APA151
System Sensor APA151System Sensor APA151
System Sensor APA151
 

Destacado (7)

Fenomenos paranormales
Fenomenos paranormalesFenomenos paranormales
Fenomenos paranormales
 
Trabajo la venezuela1830 a 1921
Trabajo la venezuela1830 a 1921Trabajo la venezuela1830 a 1921
Trabajo la venezuela1830 a 1921
 
Habilidades sociales 5
Habilidades sociales 5Habilidades sociales 5
Habilidades sociales 5
 
Catalogo Nadìr adv
Catalogo Nadìr advCatalogo Nadìr adv
Catalogo Nadìr adv
 
Am J Clin Nutr-2016-Best-128-43
Am J Clin Nutr-2016-Best-128-43Am J Clin Nutr-2016-Best-128-43
Am J Clin Nutr-2016-Best-128-43
 
Unit 5,Task 3
Unit 5,Task 3Unit 5,Task 3
Unit 5,Task 3
 
Task 2 Media Interactive Features
Task 2 Media Interactive FeaturesTask 2 Media Interactive Features
Task 2 Media Interactive Features
 

Similar a Newsbook 2016 / 2017 - English

Similar a Newsbook 2016 / 2017 - English (20)

ifmnovation newsbook 2017 (EN)
ifmnovation newsbook 2017 (EN)ifmnovation newsbook 2017 (EN)
ifmnovation newsbook 2017 (EN)
 
Innovations 2014
Innovations 2014Innovations 2014
Innovations 2014
 
Ifm Innovations English 2013-2014
Ifm Innovations English 2013-2014Ifm Innovations English 2013-2014
Ifm Innovations English 2013-2014
 
Innovations 2014/2015 au
Innovations 2014/2015 auInnovations 2014/2015 au
Innovations 2014/2015 au
 
Innovations 2014/2015 gb
Innovations 2014/2015 gbInnovations 2014/2015 gb
Innovations 2014/2015 gb
 
Innovations 2014/2015 uk
Innovations 2014/2015 ukInnovations 2014/2015 uk
Innovations 2014/2015 uk
 
Innovations Catalogue 2012
Innovations Catalogue 2012Innovations Catalogue 2012
Innovations Catalogue 2012
 
Telemecanique Sensors Briefing - Safety Rope Switches
Telemecanique Sensors Briefing - Safety Rope SwitchesTelemecanique Sensors Briefing - Safety Rope Switches
Telemecanique Sensors Briefing - Safety Rope Switches
 
Telemecanique Limit Switches Briefing
Telemecanique Limit Switches BriefingTelemecanique Limit Switches Briefing
Telemecanique Limit Switches Briefing
 
Sensor catalogue
Sensor catalogueSensor catalogue
Sensor catalogue
 
Sensor catalogue
Sensor catalogueSensor catalogue
Sensor catalogue
 
Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series
 Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series
Mod mag m5000 datasheet badger meter electromagnetic flow meter_m-series
 
Proximity Switches Briefing
Proximity Switches BriefingProximity Switches Briefing
Proximity Switches Briefing
 
Brosur Metrel MI 2885 Master Q4
Brosur Metrel MI 2885 Master Q4 Brosur Metrel MI 2885 Master Q4
Brosur Metrel MI 2885 Master Q4
 
Catalog thiết bị báo mức Kansai Automation
Catalog thiết bị báo mức Kansai AutomationCatalog thiết bị báo mức Kansai Automation
Catalog thiết bị báo mức Kansai Automation
 
Track 1 session 7 - st dev con 2016 - smart cities
Track 1   session 7 - st dev con 2016 - smart citiesTrack 1   session 7 - st dev con 2016 - smart cities
Track 1 session 7 - st dev con 2016 - smart cities
 
Ultrasonic flow meter catalog
Ultrasonic flow meter catalogUltrasonic flow meter catalog
Ultrasonic flow meter catalog
 
Position Sensor SPS-L075-HALS
Position Sensor SPS-L075-HALSPosition Sensor SPS-L075-HALS
Position Sensor SPS-L075-HALS
 
PCS
PCSPCS
PCS
 
ATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdfATI-Q46H-C4-Datasheet.pdf
ATI-Q46H-C4-Datasheet.pdf
 

Más de ifm electronic gmbh

Más de ifm electronic gmbh (20)

Valve Feedback
Valve FeedbackValve Feedback
Valve Feedback
 
Rückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und SchwenkantriebeRückmeldesysteme für Hubventile und Schwenkantriebe
Rückmeldesysteme für Hubventile und Schwenkantriebe
 
IO-Link – we connect you! Catalogo 2017/2018 (IT)
IO-Link – we connect you! Catalogo 2017/2018 (IT)IO-Link – we connect you! Catalogo 2017/2018 (IT)
IO-Link – we connect you! Catalogo 2017/2018 (IT)
 
IO-Link - we connect you! Katalog 2017/2018
IO-Link - we connect you! Katalog 2017/2018IO-Link - we connect you! Katalog 2017/2018
IO-Link - we connect you! Katalog 2017/2018
 
IO-Link - we connect you! Catalogue 2017/2018 (EN)
IO-Link - we connect you! Catalogue 2017/2018 (EN)IO-Link - we connect you! Catalogue 2017/2018 (EN)
IO-Link - we connect you! Catalogue 2017/2018 (EN)
 
ifmnovation newsbook 2017 (DE)
ifmnovation newsbook 2017 (DE)ifmnovation newsbook 2017 (DE)
ifmnovation newsbook 2017 (DE)
 
From vibration monitoring to Industry 4.0
From vibration monitoring to Industry 4.0From vibration monitoring to Industry 4.0
From vibration monitoring to Industry 4.0
 
Von der Schwingungsüberwachung zu Industrie 4.0
Von der Schwingungsüberwachung zu Industrie 4.0 Von der Schwingungsüberwachung zu Industrie 4.0
Von der Schwingungsüberwachung zu Industrie 4.0
 
Newsbook 2016 / 2017 Automation Technology (Chinese)
Newsbook 2016 / 2017 Automation Technology (Chinese)Newsbook 2016 / 2017 Automation Technology (Chinese)
Newsbook 2016 / 2017 Automation Technology (Chinese)
 
Sensores y soluciones completas de ifm.
Sensores y soluciones completas de ifm.Sensores y soluciones completas de ifm.
Sensores y soluciones completas de ifm.
 
ifm超音波感應器
ifm超音波感應器ifm超音波感應器
ifm超音波感應器
 
Один диапазон срабатывания для всех металлов. Индуктивные датчики
Один диапазон срабатывания для всех металлов. Индуктивные датчикиОдин диапазон срабатывания для всех металлов. Индуктивные датчики
Один диапазон срабатывания для всех металлов. Индуктивные датчики
 
Prozesse in der Windindustrie
Prozesse in der WindindustrieProzesse in der Windindustrie
Prozesse in der Windindustrie
 
Prozesse in der Werkzeugmaschinenindustrie
Prozesse in der WerkzeugmaschinenindustrieProzesse in der Werkzeugmaschinenindustrie
Prozesse in der Werkzeugmaschinenindustrie
 
Prozesse in der Stahlindustrie
Prozesse in der StahlindustrieProzesse in der Stahlindustrie
Prozesse in der Stahlindustrie
 
Prozesse in der Lebensmittelindustrie
Prozesse in der LebensmittelindustrieProzesse in der Lebensmittelindustrie
Prozesse in der Lebensmittelindustrie
 
Prozesse in der Automobilindustrie
Prozesse in der AutomobilindustrieProzesse in der Automobilindustrie
Prozesse in der Automobilindustrie
 
Process dans la sidérurgie
Process dans la sidérurgieProcess dans la sidérurgie
Process dans la sidérurgie
 
Il primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifm
Il primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifmIl primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifm
Il primo passo verso la rivoluzione industriale: soluzioni IO-Link di ifm
 
Rilevamento e analisi di oggetti e scene con i sensori di visione
Rilevamento e analisi di oggetti e scene con i sensori di visioneRilevamento e analisi di oggetti e scene con i sensori di visione
Rilevamento e analisi di oggetti e scene con i sensori di visione
 

Último

Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Safe Software
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
?#DUbAI#??##{{(☎️+971_581248768%)**%*]'#abortion pills for sale in dubai@
 

Último (20)

FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024FWD Group - Insurer Innovation Award 2024
FWD Group - Insurer Innovation Award 2024
 
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot TakeoffStrategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
Strategize a Smooth Tenant-to-tenant Migration and Copilot Takeoff
 
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot ModelNavi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
Navi Mumbai Call Girls 🥰 8617370543 Service Offer VIP Hot Model
 
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin WoodPolkadot JAM Slides - Token2049 - By Dr. Gavin Wood
Polkadot JAM Slides - Token2049 - By Dr. Gavin Wood
 
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers:  A Deep Dive into Serverless Spatial Data and FMECloud Frontiers:  A Deep Dive into Serverless Spatial Data and FME
Cloud Frontiers: A Deep Dive into Serverless Spatial Data and FME
 
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWEREMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
EMPOWERMENT TECHNOLOGY GRADE 11 QUARTER 2 REVIEWER
 
GenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdfGenAI Risks & Security Meetup 01052024.pdf
GenAI Risks & Security Meetup 01052024.pdf
 
A Beginners Guide to Building a RAG App Using Open Source Milvus
A Beginners Guide to Building a RAG App Using Open Source MilvusA Beginners Guide to Building a RAG App Using Open Source Milvus
A Beginners Guide to Building a RAG App Using Open Source Milvus
 
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
+971581248768>> SAFE AND ORIGINAL ABORTION PILLS FOR SALE IN DUBAI AND ABUDHA...
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)Powerful Google developer tools for immediate impact! (2023-24 C)
Powerful Google developer tools for immediate impact! (2023-24 C)
 
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
Apidays Singapore 2024 - Scalable LLM APIs for AI and Generative AI Applicati...
 
Strategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a FresherStrategies for Landing an Oracle DBA Job as a Fresher
Strategies for Landing an Oracle DBA Job as a Fresher
 
Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024Axa Assurance Maroc - Insurer Innovation Award 2024
Axa Assurance Maroc - Insurer Innovation Award 2024
 
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
Emergent Methods: Multi-lingual narrative tracking in the news - real-time ex...
 
AWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of TerraformAWS Community Day CPH - Three problems of Terraform
AWS Community Day CPH - Three problems of Terraform
 
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, AdobeApidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
Apidays New York 2024 - Scaling API-first by Ian Reasor and Radu Cotescu, Adobe
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024Manulife - Insurer Transformation Award 2024
Manulife - Insurer Transformation Award 2024
 

Newsbook 2016 / 2017 - English

  • 1. Newsbook 2016 / 2017 Automation Technology
  • 2. 3 Inductive sensors Encoders Position sensors Inductive sensors take a leap forward Kplus sensors: one sensing range for all metals (11.2016) (04.2016) 6 - 7 8 - 9 Infrared sensors / red light sensors This tiny new photocell O8 is the next big thing (11.2016) Ingeniously simple: display guide for the perfect setting Capacitive sensors (11.2016) 10 - 11 Very robust position sensors with 1 mm-thick metal face Cylinder sensors (04.2016) 12 - 13 18 - 19 Ultrasonic sensors Precise object detection under extreme conditions Object detection for long ranges and difficult surfaces (04.2016) (04.2016) 14 - 15 16 - 17 Intelligent incremental encoder with display and IO-Link (04.2016) Sensors for motion control 28 - 29 Robust speed sensors – also with ATEX approval Speed sensors (04.2016) 30 - 31 Decentralised display, preprocessing and conversion of analogue signals Multifunctional display: speed, time, counter Systems for pulse evaluation (11.2016) (11.2016) 32 - 33 34 - 35 TOP TOP TOP TOP TOP TOP Laser sensors / distance measurement sensors The next step in photoelectric sensing with distance display The next step in photoelectric sensing with easy setting (11.2016) (11.2016) 20 - 21 22 - 23 Valve feedback systems for rising stem valves and quarter-turn actuators Valve feedback sensor with easy wiring Feedback for hand valves (11.2016) (11.2016) 24 - 25 26 - 27 TOP Camera systems for mobile machines Augmented reality: mobile 3D smart camera with overlay function Mobile 3D camera – 2D and 3D in one unit (11.2016) (11.2016) Industrial imaging 36 - 37 38 - 39 TOP TOP
  • 3. 4 Pressure sensors AS-Interface cable extensions Process sensors Pressure transmitters with DEUTSCH, AMP or M12 connector for mobile applications Hydrostatic level measurement for a wide range of applications New PT absolute pressure transmitter with different measuring ranges IO-Link display: process values at a glance (04.2016) (04.2016) (04.2016) (04.2016) 48 - 49 50 - 51 52 - 53 54 - 55 Calorimetric flow meter for liquids and gases Flow sensors / flow meters (04.2016) 56 - 57 Temperature sensors Two temperature sensors in one Temperature sensor with easy dial setting TN sensor with integrated process connection and evaluation electronics Temperature sensors with DEUTSCH, AMP or M12 connector (11.2016) (11.2016) (04.2016) (04.2016) Repeater to extend AS-i networks up to 1000 m (04.2016) Industrial communication SafeLine SmartPLC: fail-safe automation system AS-Interface Safety at Work (11.2016) 4-port IO-Link master: intelligent connection of sensors LR DEVICE Parameter setting software via IO-Link master LR SENSOR Parameter setting software, point-to-point, for IO-Link devices IO-Link components (11.2016) (11.2016) (11.2016) AS-Interface controllers / gateways DataLine SmartPLC: flexible automation system (11.2016) TOP TOP TOP TOP TOP Camera systems for mobile machines True 3D vision sensor with intelligent functions 3D sensors for mobile machines MultiViewBox: display up to 4 camera images on one screen (04.2016 (04.2016 (11.2016) Industrial imaging 40 - 41 42 - 43 44 - 45 Photoelectric 3D level measurement and point level detection 3D sensors (11.2016) 46 - 47 TOP 58 - 59 60 - 61 62 - 63 64 - 65 68 - 69 70 - 71 72 - 73 74 - 75 76 - 77 66 - 67
  • 4. 5 RFID 125 kHz / RFID 13.56 MHz RFID evaluation system DTE with EtherCAT (04.2016) Identification systems RFID with CANopen or J1939 interface for mobile machines RFID 13.56 MHz (04.2016) Diagnostic and service units Real-time clock with CAN interface CANwireless: wifi and Bluetooth for the CAN bus (11.2016) (11.2016) Systems for mobile machines Sockets Always a reliable connection. ecolink M12 – even for special applications ecolink M12 cables reduce voltage drop ecolink M12 – the secure connection even in difficult applications (11.2016) (11.2016) (11.2016) Connection technology T splitters ecolink M12 – T splitters for difficult applications (11.2016) 24 V DC switched-mode power supplies Powerful switched-mode power supply with an enormous power reserve (04.2016) Power supplies Accessories Circuit protection with monitoring function for the 24 V secondary circuit (04.2016) Splitter boxes Compact low-profile M8 splitters with secure ecolink connection (11.2016) 78 - 79 80 - 81 82 - 83 84 - 85 86 - 87 88 - 89 90 - 91 94 - 95 96 - 97 98 - 99 92 - 93
  • 5. 6 Position sensors Inductive sensors take a leap forward Inductive sensors Precise position monitoring Digital transmission of target distance High linearity and repeatability High IP 69K and wide temperature range Function and polarity selectable via IO-Link Much more than just a pulse pick-up! ifm’s new inductive sensors with IO-Link incorporate several functions in one unit. They can be used as switching sensors with an adjustable switch point or measuring systems with a measured value transmitted via IO-Link. The output signal can be set to NC or NO and PNP or NPN allowing many possible combinations. This keeps the number of different types down, reducing the cost of stock. Highest precision The new sensors are so precise that they detect even minute changes. Even the true run of a spindle or the tension of a saw blade is reliably detected. An alarm can be set if the target leaves the detection zone or comes too close to the sensing face. All data acquired can be transmitted via IO-Link and recorded. This new development is unbeatable.
  • 6. 7 (11.2016) Detection zone [mm] Housing material f [Hz] Order no. M12 connector· 3-wire DC InstallationType Dimensions [mm] Operating voltage [V DC] 10...30 Electrical design DC PNP / NPN can be set via IO-Link Output function Normally open / normally closed can be set via IO-Link Current rating [mA] 100 Reverse polarity protection • Short-circuit protection • Protection class III Switching status indication [LED] yellow IO-Link V1.1; COM2; 3 ms cycle time; smart sensor profiles; single point mode; two point mode; window mode Further technical data Connection technology Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 For further technical details please visit: www.ifm.com 60 0.375...3.75 coated brass 600 IF6123M12 M12 M18 M18 Rectangular Rectangular 60 0.7...7 coated brass 600 IF6124 60 0.75...7.5 coated brass 300 IG6615 60 1.3...13 flush non flush flush non flush coated brass 300 IG6616 M30 M30 65 1.3...13 coated brass 100 II5973 65 2.3...23 flush non flush coated brass 100 II5974 40 x 40 2.1...21 PA100 IM5172 40 x 40 2.6...26 PA100 IM5173 flush non flush Ambient temperature [°C] -40...85 -40...85 -40...85 -40...85 -40...85 -40...85 -25...80 -25...80 Protection rating IP 65, IP 66, IP 67, IP 68, IP 69K IP 65, IP 66, IP 67, IP 68, IP 69K IP 65, IP 66, IP 67, IP 68, IP 69K IP 65, IP 66, IP 67, IP 68, IP 69K IP 65, IP 66, IP 67, IP 68, IP 69K IP 65, IP 66, IP 67, IP 68, IP 69K IP 67 IP 67 Dimensions Example IF6124 Example IG6616 Example II5974 Type Description Order no. Accessories Angle bracket for type M30, stainless steel E10737 Mounting clamp, with end stop for types M12, PC E11994 Mounting clamp, with end stop for types M18, PC E11995 Mounting clamp, with end stop for types M30, PC E11996 Angle bracket for type M12, stainless steel E10735 Angle bracket for type M18, stainless steel E10736 49 40 M12x1 17 4 M12x1 60 LED 4 x 90° 5 M18x1 35 10 M12x1 60 LED 4 x 90° 49 24 4 53 34 M30x1,5 5 52 65 M12x1 LED 4 x 90° 15 36
  • 7. 8 Inductive sensors Kplus sensors: one sensing range for all metals Uniform sensing range for the reliable detection of all metals Compact dimensions for use in the smallest of space Electromagnetic field immune sensor technology to prevent incorrect switching High-quality stainless steel housing High reliability thanks to protection rating from IP 65 / IP 69K Constant correction factor Kplus sensors have the same sensing range for all types of metals. They are for example perfectly suited for the detection of aluminium, where conventional sensors show a considerably reduced sensing range. The high switching frequencies enable the monitoring of fast changing switching states. The resistant stainless steel sleeve allows reliable use in oil and coolant applications. The wide temperature range as well as the high protection ratings enable universal use of the new Kplus sensors. Position sensors
  • 8. 9 (04.2016) Sensing range [mm] Current rating [mA] Switching frequency [Hz] Order no. M12 connector · 3 wire DC PNP · Output function normally open InstallationType Total length [mm] Further technical dataConnection technology Type Description Order no. 34 30 M12x1 4 M12x1 45 LED 4 x 90° 17 4 17LED 4 x 90° 35 49 60 M12x1 M12x1 10 M18x1 M12x1 30 45 34 4 LED 4 x 90° 24 M18x1 30 15 M12x1 60 LED 4 x 90° 49 24 4 45 34 30 LED 4 x 90° M12x1 M30x1,5 5 36 49 60 22,5 M30x1,5 M12x1 LED 4 x 90° 5 36 22,5 45 4 1002000 IFS297M12 M12 M12 M12 M18 M18 45 8 1002000 IFS298 45 10 1002000 IFS299 60 4 1002000 IFS304 M12 M12 60 8 1002000 IFS305 60 10 1002000 IFS306 45 8 1002000 IGS287 45 12 1002000 IGS288 M18 M18 45 15 1002000 IGS289 60 8 1002000 IGS290 M18 M18 60 12 1002000 IGS291 60 15 1002000 IGS292 M30 M30 45 15 1002000 IIS281 60 15 1002000 IIS282 M30 60 22 1002000 IIS283 M30 60 30 1002000 IIS284 flush non-flush non-flush flush non-flush non-flush flush non-flush non-flush flush non-flush non-flush flush flush non-flush non-flush Operating voltage [V DC] 10...30 Reverse polarity protection • Short-circuit protection • Overload protection • Protection rating IP 65 / IP 66 / IP 67 / IP 68 / IP 69K Protection class III Ambient temperature [°C] -40...85 Output status indication [LED] yellow (4 x 90°) Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 For further technical details please visit: www.ifm.com Housing materials High-grade stainless steel (316L) sensing face LCP Dimensions Example IFS297 Example IFS306 Example IGS287 Example IGS292 Example IIS281 Example IIS284
  • 9. 10 Position sensors Ingeniously simple: display guide for the perfect setting Capacitive sensors Unique visualisation and handling concept via LED display See and compensate switch point movement IP 69K gives high ingress resistance PNP/NPN, NO/NC, timer function For medium temperatures up to 110 °C Visualised switch point The new capacitive sensors stand out not only because of their excellent technical data but most of all with their new and unique visualisation concept. Using a 12-LED bar display of the PerformanceLine the user can always adapt the switch point to suit the application conditions – it is always in the centre of the display. The green LEDs either side of the switch point indicate the reliability of the switch point. Deposits, material changes etc. are displayed directly on the sensor and the user can readjust the switch point precisely as needed. An imminent error can be detected in good time and avoided thus minimising the risk of failures or deactivation. If help is needed with the effects of process changes this is much easier to explain and rectify with the LED display. Over the phone the user can describe the LED behaviour and a support engineer can easily advise corrective measures.
  • 10. 11 (11.2016) Further technical data PerfomanceLine · M12 connector ·3 wires StandardLine · connection cable 2 m PUR· 3 wires Type Description Order no. Mounting accessories Type Description Order no. Operating voltage [V DC] 10...30 Short-circuit protection • Reverse polarity / overload protection • / • Ambient temperature [°C] -25...80 Mounting clamp with end stop for M18 types E11048 Mounting clamp with end stop for M30 types E11049 Fixing clamp with reducing bush for M18 types E10076 Fixing clamp with reducing bush for M30 types E10077 Mounting adapter for M30 types, G 1 1/1", POM E11033 Mounting adapter for M30 types, G 1 1/4", PVDF Switching frequency [HZ] 40 Medium temperature [°C] -25...110 Housing material PBT Type Output stage Sensing range [mm] Protection rating/ protection class Order no. Setting range [mm] Communication interface For further technical details please visit: www.ifm.com Memory plug, parameter memory for IO-Link sensors E30398 LINERECORDER SENSOR, software for parameter setting and setting up IO-Link sensors QA0001 IO-Link master with Profibus interface AL1010 IO-Link master with EtherNet/IP interface AL1020 USB IO-Link master for parameter setting and analysis of units Supported communication protocols: IO-Link (4.8, 38.4 and 230 kBits/s) E30390 M30 PNP, NO/NC 25 nf IP 65, IP 67, IP 69K / III KI60000.5...40 M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5300 M30 PNP, NC 25 nf IP 65, IP 67, IP 69K / III KI5301 0.5...40 0.5...40 IO-Link COM 2 IO-Link COM 2 M30 NPN, NC 25 nf IP 65, IP 67, IP 69K / III KI5302 M30 PNP, NO 25 nf IP 65, IP 67, IP 69K / III KI5303 0.5...40 0.5...40 IO-Link COM 2 IO-Link COM 2 M30 PNP, NC 15 qf IP 65, IP 67, IP 69K / III KI5304 M30 PNP, NO 15 qf IP 65, IP 67, IP 69K / III KI5305 0.5...24 0.5...24 IO-Link COM 2 IO-Link COM 2 M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5306 M30 PNP, NC 25 nf IP 65, IP 67, IP 69K / III KI5307 0.5...40 0.5...40 IO-Link COM 2 IO-Link COM 2 M30 NPN, NO 25 nf IP 65, IP 67, IP 69K / III KI5308 M30 PNP, NO 25 nf IP 65, IP 67, IP 69K / III KI5309 0.5...40 0.5...40 IO-Link COM 2 IO-Link COM 2 M30 PNP, NC 15 qf IP 65, IP 67, IP 69K / III KI5310 M30 PNP, NO 15 qf IP 65, IP 67, IP 69K / III KI5311 0.5...24 0.5...24 IO-Link COM 2 IO-Link COM 2 M18 NPN, NO 15 nf IP 65, IP 67, IP 69K / III KG5306 M18 PNP, NC 15 nf IP 65, IP 67, IP 69K / III KG5307 0.5...30 0.5...30 IO-Link COM 2 IO-Link COM 2 M18 NPN, NO 15 nf IP 65, IP 67, IP 69K / III KG5308 M18 PNP, NO 15 nf IP 65, IP 67, IP 69K / III KG5309 0.5...30 0.5...30 IO-Link COM 2 IO-Link COM 2 M18 PNP, NC 8 qf IP 65, IP 67, IP 69K / III KG5310 M18 PNP, NO 8 qf IP 65, IP 67, IP 69K / III KG5311 0.5...9 0.5...9 IO-Link COM 2 IO-Link COM 2 IO-Link COM 2 M18 PNP, NO/NC 15 nf IP 65, IP 67, IP 69K / III KG60000.5...30 IO-Link COM 2 Mounting adapter for M18 types, G 3/4", POM E43900 Mounting adapter for M18 types, G 1", PVDF E43904 IO-Link accessories StandardLine · M12 connector ·3 wires
  • 11. 12 Position sensors Very robust position sensors with 1 mm-thick metal face Cylinder sensors Extremely pressure resistant with over 10 million pressure cycles Best value performer Complementary output provides higher operational reliability Standard M12 housing with ingress-resistant cable entry Short housing (40 mm) for extremely low-profile cylinders Function principle The new MFH series sensor is suited for flush mounting in various steels. With its 1.8 mm sensing range it shows reliable switching characteristics. The new operating principle of this unit is based on a magnetic-inductive technology that detects only ferromagnetic metals (e.g. steel). It is sealed by means of an O-ring and a supporting ring towards the pressure area. Applications Besides use in hydraulic cylinders, the sensor is also ideal for other hydraulic components such as valves or pumps. MFH operates reliably for the lifetime of the cylinder. Furthermore, it is used in mechanical engineering processes, e.g. in plastic injection-moulding or process industry applications. Its attractive price means the sensor can also be considered for simple components where this option used to be too expensive.
  • 12. 13 (04.2016) For further technical details please visit: www.ifm.com M12x1 10 1824,8 4 17 M12x1 9,7 7,8 60 Connection technology Type Description Order no. M12 socket, 2 m black, PUR cable, LED EVC644 Y splitter, ”OR“ M12 connector / 2x M12 socket EBC117 Y splitter, ”AND“, M12 connector / 2x M12 socket EBC118 Type Sensing range [mm] Housing length [mm] LED OutputAmbient temperature [°C] Order no. Cable connection M12 1.8 f40 • PNP, NO-25...85 MFH205 M12 1.8 f40 • NPN NO-25...85 MFH206 M12 1.8 f40 • PNP, NC-25...85 MFH207 M12 1.8 f40 • PNP, NO/NC-25...85 MFH208 M12 1.8 f60 – PNP, NO/NC-25...120 MFH209 Operating voltage [V] 10...36 DC Current rating [mA] 200 Switching frequency [Hz] 1000 Short-circuit protection, pulsed • Protected against reverse polarity / overload protected • / • Operating pressure [bar] 500 Pressure rating , static [bar] 1000 Burst pressure [bar] 2000 Protection rating, protection class IP 65 / IP 68 / IP 69K, III Housing material stainless steel 1.4404 Common technical data Accessories Type Description Order no. Optical particle monitor LDP100 Seal process connection, set 5 O-rings + 5 supporting rings E12451 Switched-mode power supply 24 V DC / 5 A, metal housing DN4012 Dimensions Example MFH205 MFH209 Wiring M12 connector, complementary M12 socket, 2 m black, PUR cable EVC001 MFH205 MFH209 10 1820 4 17 M12x1 9,7 7,8 40 BN BK BU L+ L 4 L L+ 1 2 32: 4:
  • 13. 14 Position sensors Precise object detection under extreme conditions Ultrasonic sensors Robust high-grade stainless steel housing for demanding applications Sensing range up to 1.2 m in M18 cube design and 2.2 m in M18 design The vibrating sound transducer reduces the deposit of dirt Retro-reflective operation for orientation-independent object detection Easy setting via teach button, wire teach or IO-Link The alternative for difficult surfaces Ultrasonic sensors transmit and receive sound waves in the ultrasonic range. The object to be detected reflects the sound waves and the distance information is determined via time of flight measurement. As opposed to photoelectric sensors, colour, transparency or the object’s surface shine do not play a role. Blister packages in packaging technology or transparent plastic bowls in the food industry, for example, can be reliably detected. High performance The ifm ultrasonic sensors in M18 design provide a particularly small blind zone and long sensing ranges which are usually only achieved by sensors of a considerably larger design. The sensors operate reliably with heavy soiling so that they can be used in applications in which photoelectric sensors meet their limits.
  • 14. 15 (04.2016) For further technical details please visit: www.ifm.com Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole Housing length/ dimensions [mm] Setting 60 Type Wire Order no. UGT500 300 mm* Order no. UGT503 800 mm* Order no. UGT506 1200 mm* Order no. – 1600 mm* * Max. range Output PNP 60 Wire UGT501 UGT504 UGT507 –4...20 mA 60 Wire UGT502 UGT505 UGT508 –0...10 V Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole 53 x 20 x 38 Pushbutton UGT580 300 mm* UGT582 800 mm* UGT584 1200 mm* – 1600 mm* PNP + 4…20 mA 53 x 20 x 38 Pushbutton UGT581 UGT583 UGT585 –PNP + 0…10 V 53 x 20 x 38 Pushbutton UGT586 UGT588 UGT590 –NPN + 4…20 mA 53 x 20 x 38 Pushbutton UGT587 UGT589 UGT591 –NPN + 0…10 V Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole 98 Pushbutton, IO-Link – 300 mm* – 800 mm* – 1200 mm* UGT509 1600 mm* 2 x PNP 98 98 98 98 98 Pushbutton, IO-Link – – – – – – – – – – – – – – – UGT510PNP + 4…20 mA Pushbutton, IO-Link UGT511PNP + 0…10 V Pushbutton UGT5152x NPN Pushbutton UGT516NPN + 4…20 mA Pushbutton UGT517NPN + 0…10 V Ultrasonic retro-reflective sensor · 3-wire DC, 3-pole 98 M18 M18 M18 M18 Cube M18 Cube M18 Cube M18 Cube M18 M18 M18 M18 M18 M18 M18 Pushbutton, IO-Link – 300 mm* – 800 mm* – 1200 mm* UGR500 1600 mm* Order no. – 2200 mm* – – – 2200 mm* – – – UGT512 2200 mm* UGT513 UGT514 UGT518 UGT519 UGT520 UGR501 2200 mm* PNP Accessories Type Description Order no. Mounting set for clamp mounting, diecast zinc, Ø 12 mm E20720 Mounting set for clamp mounting, stainless steel, Ø 12 mm E21206 Mounting set for clamp mounting, diecast zinc, Ø 12 mm E20721 Mounting set for clamp mounting, stainless steel, Ø 12 mm E21207 Rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938 Rod, 200 mm, Ø 10 mm, M10 thread, stainless steel E20940 Cube for mounting on an aluminium profile, M10 thread, diecast zinc E20951 Common technical data Operating voltage [V DC] 10...30 Temperature compensation • Operating temperature range [°C] -20...70 Current rating [mA] Switching output 100 Protection IP 67 Echo LED green Status indications LED yellow Connection M12 connector Connection technology Type Description Order no. Socket, M12, 4-pole 2 m orange, PVC cable Socket, M12, 4-pole 5 m orange, PVC cable Socket, M12, 4-pole 2 m black, PUR cable Socket, M12, 4-pole 5 m black, PUR cable Socket, M12, 4-pole 2 m black, PUR cable Socket, M12, 4-pole 5 m black, PUR cable 60 Wire UGT521 UGT522 UGT523 –NPNM18 – 98M18 Pushbutton – – – UGR502 UGR503NPN EVT064 EVT001 EVC001 EVC002 EVC004 EVC005
  • 15. 16 Position sensors Object detection for long ranges and difficult surfaces Ultrasonic sensors M18 plastic housing available in the two lengths 60 mm and 98 mm Long ranges from 300 mm to 2200 mm available The vibrating sound transducer reduces the deposit of dirt Digital and analogue output for point level measurement and distance detection Easy setting via teach button, wire teach or IO-Link The alternative for difficult surfaces Ultrasonic sensors transmit and receive sound waves in the ultrasonic range. The object to be detected reflects the sound waves and the distance information is determined via time of flight measurement. As opposed to photoelectric sensors colour, transparency or the object’s surface shine do not play a role. Blister packages in packaging technology or transparent plastic bowls in the food industry, for example, can be reliably detected. High performance The ifm ultrasonic sensors in M18 design provide a particularly small blind zone and long sensing ranges which are usually only achieved by sensors of a considerably larger design. The sensors operate reliably with heavy soiling so that they can be used in applications in which photoelectric sensors meet their limits.
  • 16. 17 (04.2016) For further technical details please visit: www.ifm.com Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole Housing length/ dimensions [mm] Setting 60 Type Wire Order no. 300 mm* Order no. 800 mm* Order no. 1200 mm* Order no. – 1600 mm* * Max. range Output PNP Ultrasonic diffuse-reflection sensor · 3-wire DC, 4-pole 98 Pushbutton, IO-Link – 300 mm* – 800 mm* – 1200 mm* 1600 mm* 2 x PNP 98 98 Pushbutton, IO-Link – – – – – – PNP + 4…20 mA Pushbutton, IO-Link PNP + 0…10 V M18 M18 M18 M18 Order no. – 2200 mm* 2200 mm* Accessories Type Description Order no. Mounting set for clamp mounting, diecast zinc, Ø 12 mm E20720 Mounting set for clamp mounting, stainless steel, Ø 12 mm E21206 Mounting set for clamp mounting, diecast zinc, Ø 12 mm E20721 Mounting set for clamp mounting, stainless steel, Ø 12 mm E21207 Rod, 100 mm, Ø 12 mm, M10 thread, stainless steel E20938 Rod, 200 mm, Ø 10 mm, M10 thread, stainless steel E20940 Cube for mounting on an aluminium profile, M10 thread, diecast zinc E20951 Common technical data Operating voltage [V DC] 10...30 Temperature compensation • Operating temperature range [°C] -20...70 Current rating [mA] Switching output 100 Protection IP 67 Echo LED green Status indications LED yellow Connection M12 connector Connection technology Type Description Order no. Socket, M12, 4-pole 2 m black, PUR cable EVC001 Socket, M12, 4-pole 5 m black, PUR cable EVC002 Socket, M12, 4-pole 2 m black, PUR cable EVC004 Socket, M12, 4-pole 5 m black, PUR cable EVC005 L+ L 3 4 2 1 Wiring Example UGT204 UGT200 UGT201 UGT202 UGT203 UGT204 UGT205 UGT206 UGT207 UGT208 60 Wire UGT209 UGT210 UGT211 –NPNM18 –
  • 17. 18 Position sensors This tiny new photocell O8 is the next big thing! Infrared sensors / red light sensors Extremely reliable background suppression Range up to 80 mm independent of the colour Precise detection of very small components Reliable detection of dark or shiny surfaces IO-Link for remote setting Photoelectric miniature sensor with maximum precision The new powerful O8 sensor is an optimum choice for applications where space is at a premium such as assembly and robotics. It might be small, but the sensor achieves a range of 80 mm independent of colour and finish of the surface to be detected. Moreover the background suppression is extremely reliable and precise even for the detection of very small, flat or reflective objects. The O8 reliably copes even with constantly changing backgrounds, e.g. on robot arms. Reliable and efficient thanks to IO-Link Via IO-Link the ranges can be set to the nearest millimetre. A complex adjustment of the distance from the sensor to the object is not needed. The new sensors are also available with preset ranges. With their reliability and precision they are much above the average of conventional devices.
  • 18. 19 (11.2016) For further technical details please visit: www.ifm.com Diffuse reflection sensor with background suppression · 3 wires DC Range [mm] Spot Ø at max. range [mm] 15 Type [H, W, D] 4 Order no. O8H200 PNP IO-Link 1.1 Connection Order no. O8H201 15 4 O8H202 2 m, PVC cable 0.3 m PVC cable / M8 connector, 3 poles O8H203 15 4 O8H204 O8H205 30 4 O8H206 0.3 m PVC cable / M8 connector, 4 poles 2 m, PVC cable O8H207 30 4 O8H208 O8H209 30 4 O8H210 0.3 m PVC cable / M8 connector, 3 poles 0.3 m PVC cable / M8 connector, 4 poles O8H211 50 4 O8H212 O8H213 50 4 O8H214 2 m, PVC cable 0.3 m PVC cable / M8 connector, 3 poles O8H215 50 4 O8H216 O8H217 80 4.5 O8H218 0.3 m PVC cable / M8 connector, 4 poles 2 m, PVC cable O8H219 80 4.5 O8H220 O8H221 80 4.5 O8H222 0.3 m PVC cable / M8 connector, 3 poles 0.3 m PVC cable / M8 connector, 4 poles O8H223 NPN Accessories Type Description Order no. Angle bracket for free-standing mounting, quick mounting, stainless steel E21289 Common technical data Operating voltage [V DC] 10...30 Switching frequency [Hz] 1000 Protection rating, protection class IP65 / IP67 III Type of light / wave length red light, 633 mm Output H = light-on / D = dark-on mode H Switching status indication LED yellow Voltage drop [V] < 2.5 Short-circuit protection, pulsed • Reverse polarity / overload protection • / • Ambient temperature [°C] -25...60 Materials housing lens ABS; SUS316L PMMA Current rating [mA] 100 Operation LED green Connection technology Type Description Order no. Socket, M8, 4 poles 2 m black, PUR cable EVC150 Socket, M8, 4 poles 5 m black, PUR cable EVC151 Socket, M8, 3 poles 2 m black, PUR cable EVC141 Socket, M8, 3 poles 5 m black, PUR cable EVC142 Socket, M8, 4 poles, 2 m orange, PVC cable EVT134 Socket, M8, 4 poles, 5 m orange, PVC cable EVT135 8,1 8,85,5 28,1 M3 14,4 12,1 133 3,5 2xLED Dimensions Example O8H200 Angle bracket for free-standing mounting, stainless steel E21291 Rectangular 28.1 x 8.1 x 14.4 mm
  • 19. 20 Position sensors The next step in photoelectric sensing with distance display Laser sensors / distance measurement sensors Reliable background suppression even at 2 m Detects any surface finish or colour Not fooled by hi-vis Remote setting via IO-Link adds many options New improved performance Time of flight technology as standard sensor The O5D with time of flight technology (PMD = Photonic Mixer Device) combines the following advantages: long range, reliable background suppression, visible laser light and high excess gain. In the same price range as standard sensors, it is a clever alternative. Easy handling The switch point is set easily to the nearest centimetre via ”+/-“ buttons and display or alternatively via IO-Link, allowing read-out of the actual value. Any surface and mounting position Polished, matt, dark or light objects of any colour: the O5D features reliable background suppression. The unit allows any angle of incidence and thus flexibility of mounting. This simplifies installation and saves costs.
  • 20. 21 (11.2016) For further technical details please visit: www.ifm.com Common technical data Operating voltage [V DC] 10...30 Current consumption [mA] < 75 Switching frequency [Hz] 11 Dimensions [mm] 56 x 18.2 x 46.5 Type of light visible laser light 650 nm Extraneous light on the object [klx] max. 10 Switching status indication LED yellow Operation LED green Distance value 3-digit alphanumeric display Protection rating, protection class IP 65, IP 67 III Short-circuit protection, pulsed • Reverse polarity / overload protection • / • Ambient temperature [°C] -25...60 Current rating [mA] 2 x 100 Output function OUT1: NO OUT2: NC Connection technology Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Photoelectric distance sensor · M12 connector, complementary 30...2000 ...20 PNP < 2.5* < 5 O5D101 30...2000 ...20 O5D100PNP < 2.5* < 5 cm inch Material housing / connector front pane / LED window bezel control panel PA PMMA stainless steel TPU Accessories Type Description Order no. Mounting bracket for rod, complete set incl. clamp E21083 Protective bracket for rod, complete set incl. clamp E21084 Bracket for free-standing mounting E21087 Cube for mounting on an aluminium profile, M10 thread, diecast zinc E20951 Measuring range [mm] Background suppression [m] Output Hysteresis [%] Spot Ø at max. range [mm] Order no. Unit of measurement Laser protection class 2 2 Memory plug, parameter memory for IO-Link sensors E30398 IO-Link interface, current consumption from USB port E30396 LINERECORDER SENSOR, software for parameter setting and setting up IO-Link sensors QA0001 * at max. range Hysteresis (example O5D100) 500 1000 1500 20000 0 25 50 75 100 125 150 175 200 y x 1. 2. 30...2000 ...20 O5D102NPN < 2.5* < 5 cm2 30...2000 ...20 O5D150PNP < 4* < 5 cm1 30...2000 ...20 O5D151PNP < 4* < 5 inch1 x: distance in [mm], y: hysteresis in [mm] 1. Background black (6 % remission) 2. Background white (90 % remission)
  • 21. 22 Position sensors The next step in photoelectric sensing with easy setting Laser sensors / distance measurement sensors Dial switching distance – done! Reliable background suppression even at 2 m Detects any surface finish or colour Not fooled by hi-vis IO-Link adds many options New improved performance Time of flight technology as standard sensor The OID with time of flight technology (PMD = Photonic Mixer Device) combines the following advantages: long range, reliable background suppression, visible laser light and high excess gain. In the same price range as standard sensors, it is a clever alternative. Easy handling The switch point can be set easily by turning the setting ring (easy turn). A scale shows the distance set. The switch point can thus be set before installation. As an alternative the version without setting ring features the high protection rating IP69 K. Any surface and mounting position Reliable detection of polished, matt, dark or light objects independent of the colour. The unit allows any angle of incidence and thus flexibility of mounting. This simplifies installation and saves costs.
  • 22. 23 (11.2016) For further technical details please visit: www.ifm.com Photoelectric distance sensor · M12 connector, complementary 30...2000 ...20 PNP < 2* IP 65, IP 67 30...2000 ...20 PNP < 2* IP 65, IP 67 cm / inch cm Measuring range [mm] Background suppression [m] Output Hysteresis [%] Protection rating Order no. Unit of measurement Laser protection class 2 2 30...2000 ...20 PNP < 2* IP 65, IP 67, IP 69K cm / inch2 30...2000 ...20 NPN < 2* IP 65, IP 67 cm2 30...2000 ...20 PNP < 4* IP 65, IP 67 cm / inch1 30...2000 ...20 PNP < 4* IP 65, IP 67 cm1 30...2000 ...20 PNP < 4* • • Setting ring – • • • – IP 65, IP 67, IP 69K cm / inch1 Current consumption [mA] < 75 Switching frequency [Hz] 11 Common technical data Operating voltage [V DC] 10...30 Dimensions M30 x 90 mm Type of light visible laser light 650 nm Spot Ø at max. [mm] range < 5 Extraneous light on the object [klx] max. 10 Switching status indication LED yellow Operation LED green Short-circuit protection, pulsed • Reverse polarity / overload protection • / • Ambient temperature [°C] -25...60 Current rating [mA] 2 x 100 Output function OUT1: NO OUT2: NC Material housing front pane stainless steel, PBT, PC, FPM PMMA Hysteresis (example OID200) 500 1000 1500 20000 0 25 50 75 100 125 150 175 200 y x 1. 2. x: distance in [mm], y: hysteresis in [mm] 1. Background black (6 % remission) 2. Background white (90 % remission) Connection technology Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Type Description Order no. Accessories Angle bracket for type M30, stainless steel E10737 Mounting clamp for types M30, PTB E10077 Mounting clamp, with end stop for types M30, PC E11049 Memory plug, parameter memory for IO-Link sensors E30398 IO-Link interface, current consumption from USB port E30396 LINERECORDER SENSOR, software for parameter setting and setting up IO-Link sensors QA0001 * at max. range OID201 OID200 OID204 OID202 OID250 OID251 OID254
  • 23. 24 Position sensors Valve feedback sensor with easy wiring Valve feedback systems for rising stem valves and quarter-turn actuators Heavy-duty housing for long life Integrated solenoid wiring Lasered label can be read even when wet Clearly visible status indication Spacious terminal chamber for easy access End position feedback on quarter-turn actuators The unit contains two inductive sensors in a potted and sturdy housing with protection rating IP 67. It signals two end positions. It is equipped with a solenoid connection replacing the additional cable to the solenoid valve. Fast and easy wiring The actuator interface is optionally equipped with a standardised M20 x 1 gland. The spacious terminal chamber allows quick and easy wiring. Since the terminal block can be removed, no new wiring is required if the sensor is replaced. A UL approval for this product is currently in progress.
  • 24. 25 (11.2016) For further technical details please visit: www.ifm.com Ambient temperature [°C] Protection Order no. Terminal chamber 20…250 AC/DC -25...70 IP65 / IP67, II IN01312 x M20 x 1.5 Output function 2 x normally open Connection Sensor / valve Ub [V] Switching frequency [Hz] 25 AC / 50 DC Sensing range [mm] 4 Electrical design AC/DC Housing material PA Minimum load current [mA] 5 Further technical dataDimensions 33 92 6,3 18,8 60 7,5 5,5 30 60 M20x1,5 1) Sensor 1 2) Sensor 2 3) LED OUT 2 4) LED OUT 1 4 6 7 8 5 IN + IN - OUT+ OUT- 3 A1 1 2 L1 / L+ A2 2 A Wiring diagram Leakage current [mA] < 2.5 (250 V AC), < 1.3 (110 V AC), < 0.8 (24 V DC) Current rating [mA] (Duration) 350 AC (...50 °C) / 250 AC (...70 °C) / 100 DC Current rating [mA] (In brief) î: 2.2 A (20 ms / 0.5 Hz) Environmental conditions [°C] -25...70 Connection Screw terminals Accessories Type Description Order no. Plug for covering the oblong holes, EPDM E12212 Protective cap, PA 6.6 E12209 Target puck Ø 53 mm E17320 Target puck Ø 102 mm E17328 Spacer for ifm puck, PA E12084 Cable gland, M20 x 1.5, PA 6.6 E12208
  • 25. 26 Position sensors Feedback for hand valves Valves sensors, accessories Suitable for ISO top flange valves from F04 to F10 Easy installation on manual valves and ball valves Height-adjustable for flexibility Stainless steel components for long life Ideal for hazardous areas End position feedback for manual valves and ball valves With this mounting kit, you can very easily equip your manual valves with sensors and target pucks. A large number of sensors and pucks can be used on the 80 x 30 mm actuator interface to VDI/VDE 3845. The entire system can be used at ambient temperatures from -30 to +80 °C. Versatile and flexible The upper part is made out of Vestamid and allows operation in hazardous areas. The lower part fits on many ISO flange valves (DIN EN ISO 5211) and is connected to the valve shaft by a shaft extension. Stainless steel components guarantee increased service life.
  • 26. 27 (11.2016) E12520 (F05/M5)/ E12521 (F05/M6) E12524 (F10/M8) Order no. E12522 (F07/M6)/ E12523 (F07/M8) E12519 (F04/M5) Accessories Type Description Order no. Inductive sensor, PBT, M12 connector IN5327 Target puck Ø 53 mm, PA 6, V2A (1.4302) E17320 Plug for covering the oblong holes, EPDM E12212 NN5008 For further technical details please visit: www.ifm.com 20.70A B C D H1 H2 20 60 54 D4 D5 42 5.3 60 70 H3 H4 80 90 H5 100 24.36 15 60 54 50 6.5 60 70 80 90 100 34.50 15 65 54 70 8.5 60 70 80 90 100 52.12 15 93 74 102 11 80 90 100 110 120 Dimensions Connection technology Type Description Order no. Socket, M12, 5 m orange, PVC cable EVT001 Socket, M12, ATEX approval 5 m, blue, PUR cable ENC02A Switching amplifiers for Namur sensors, 2 channels N0532A AS-i sensor, M12 connector AC2315 NAMUR sensor (1D,1G, 2G), M12 connector 15 C 4 4,8 25 5 620 12H1 H2 H3 H4 H5 A D B 13 4,8 D5 12 4 60 4 M D4
  • 27. 28 Sensors for motion control Intelligent incremental encoder with display and IO-Link Encoders Resolution of 2...10,000 and signal level (TTL / HTL) freely programmable Display: Two-colour electronic rotatable display of the process values Versatile: M12 connector can be used radially or axially Standard fitting: Solid shaft (clamp / synchro flange) or hollow shaft design Motion controller: Encoder, speed/direction monitor and counter all in one The magnetic sensing principle provides the accuracy of photoelectric encoders and the robustness of magnetic systems. Resolution and signal level can be programmed. The encoders have a wide voltage range of 4.75...30 V DC and are therefore suited for universal use. Performance Line encoders have an integrated signal evaluation for speed monitoring, counter functions and detection of the direction of rotation. They provide easy setting, position indication by means of display and operating keys and intuitive menu navigation. Diagnostic and parameter data are reliably transferred via IO-Link. Ready for Industry 4.0.
  • 28. 29 (04.2016) For further technical details please visit: www.ifm.com Flange IO-LinkResolution [pulse/revolution] Order no. Hollow shaft with integrated stator coupling· 4-digit display · Integrated pulse evaluation direct •max. 10,000 (adjustable) ROP52012 Operating voltage [V DC] 4.75...30 Shaft Ø [mm] Solid shaft · 4-digit display · Integrated pulse evaluation synchro •max. 10,000 (adjustable) RUP5006 4.75...30 clamp flange •max. 10,000 (adjustable) RVP51010 4.75...30 Protection IP 65, IP 67 Connection M12 connector (rotatable) Further technical data 58 58 58 Housing Ø [mm] Switching frequency [kHz] 1000 Accessories Type Description Order no. Spring disc coupling, Ø 6 mm / 10 mm, die-cast zinc; PA E60117 Spring disc coupling, Ø 10 mm / 10 mm, die-cast zinc; PA E60118 Flexible coupling with clamp connection, Ø 6 mm / 10 mm, aluminium E60066 Flexible coupling with clamp connection, Ø 10 mm / 10 mm, aluminium E60067 Flexible coupling with adjusting screws, Ø 10 mm / 10 mm, aluminium E60022 Flexible coupling with adjusting screws, Ø 6 mm / 10 mm, aluminium E60028 Measuring wheel, Ø 159.15 mm / 10 mm, Hytrel TPE-E E60110 Measuring wheel, Ø 159.16 mm / 10 mm, aluminium, PU E60076 Measuring wheel, Ø 63.66 ± 0.1 mm / 10 mm, Hytrel TPE-E E60138 Measuring wheel, Ø 63.6 mm, 10 mm, aluminium E60095 Measuring wheel, Ø 63.66 ± 0.1 mm / 6 mm, aluminium E60137 Measuring wheel, Ø 63.6 mm, 6 mm, aluminium E60006 Angle bracket for RUP design, aluminium, black anodised E60033 Angle bracket for RUP design, aluminium, black anodised E60035 Fastening clamp for synchro flange, steel E60041 Memory plug, parameter memory for IO-Link sensors E30398 LINERECORDER SENSOR, Software for parameter setting and set-up of IO-Link sensors QA0001 Accessories Type Description Order no. Connection technology Type Description Order no. M12 socket, shielded, 5 m black, PUR cable, 8 poles E12403 M12 socket, shielded, 10 m black, PUR cable, 8 poles E12404 M12 socket, shielded, 2 m black, PUR cable, 8 poles E12402 USB IO-Link master for parameter setting and analysis of units Supported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s) E30390 Adapter cable for the connection between USB IO-Link master E30390 and 3-pole / 8-pole encoder E12432 Flexible coupling with clamp connection, Ø 6 mm / 1/4", aluminium E60206 Flexible coupling with clamp connection, Ø 6 mm / 3/8", aluminium E60207 Flexible coupling with clamp connection, Ø 10 mm / 1/2", aluminium E60208 Flexible coupling with clamp connection, Ø 10 mm / 3/8", aluminium E60209 Connection cable, M23 plug / M12 socket, PUR cable, shielded, 0.3 m black, 8 poles E12460
  • 29. 30 Sensors for motion control Robust speed sensors – also with ATEX approval Speed sensors Robust M30 metal housing, no additional impact protection housing required Ideal in combination with a PLC Flush installation Flexible voltage supply: (20...250 AC/DC) ATEX approval group II, category 3D Compact speed monitoring The new speed sensors are the compact solution for speed monitoring because the evaluation electronics are integrated in the sensor housing. The limit at the speed of which the output switches is set via a potentio- meter. Both rotary and linear movements can be monitored for overspeed, underspeed and blockage. As compared to its predecessors, these new sensors feature a robust metal housing for flush mounting. A special version with ATEX approval is available for which no additional impact protection is required.
  • 30. 31 (04.2016) For further technical details please visit: www.ifm.com Operating voltage [V] Start-up-delay [s] Ambient temperature [°C] ATEX approvalMax. load current [mA] Order no. M30 x 1.5 inductive sensor · connection cable 20...250 AC/DC (45...65 Hz, AC) 12 -25...80 – 350 AC (50 °C), 250 AC / 100 DC (80 °C) DI0101 20...250 AC/DC (45...65 Hz, AC) < 0.5 -25...80 – 350 AC (50 °C), 250 AC / 100 DC (80 °C) DI0104 20...250 AC/DC (45...65 Hz, AC) 12 -20...60 Group II, category 3D 200 AC / 100 DC (60 °C) DI103A Further technical data Setting range [pulses/min] 5...3600 Switch point setting Multiturn potentiometer Switching status indication LED 2 x yellow Housing materials Brass special coating; PA (Polyamid); TPE-U Connection PUR cable, 2m Protection rating IP 65, IP 67 Protection class II Accessories Type Description Order no. Applications Especially in the field of conveying technology the compact speed sensors can be used for various applica- tions, for example for monitoring belt conveyors or bucket elevators. Here they are typically used to monitor underspeed, blockage or standstill. Advantages The speed sensors incorporate the complete speed monitoring because the evaluation electronics and the sensor are integrated in one housing. The switch point is set using a multi-turn potentiometer. Hysteresis and start-up delay are firmly set. Operation The integrated sensor is damped by passing cams or other metallic targets. On the basis of the time interval between damping the evaluation unit determines the period duration or the frequency (actual rotational speed value) and compares it to the set switch point (preset value). The output is switched during the start-up delay and when the rotational speed exceeds the set switching value. An LED signals underspeed and switch-off of the output. Dimensions 80 75,5 M30x1,5 5,4 2,2 36 5 1 LEDs 1) potentiometer WH BK L1 L+ L N Wiring Target wheel E89010 Mounting clamp with end stop for M30 types E11049 Fixing clamp with reducing bush for M30 types E10077 Angle bracket for M30 types E10737 Lock nuts, nickel-plated brass E10030 Lock nuts, high-grade stainless steel (316Ti/1.4571) E10031 Mounting set, free-standing M12 clamp mounting, Ø 30.2 mm E20873 Mounting set, aluminium profile clamp mounting, Ø 30.2 mm E20875 Clamp with damping cams E89013
  • 31. 32 Sensors for motion control Decentralised display, preprocessing and conversion of analogue signals Pulse evaluation systems Mini display to monitor values Clearly visible display with red/green colour change Compact design with protection rating IP 67 Parameter setting via IO-Link Conversion of analogue measured values to an IO-Link communication Analogue signals at a glance The compact connector unit is simply inserted in the connection cable of analogue sensors (4...20 mA). It displays the measured values locally. The user can set a switch point or limit at which the transistor output switches. A colour change (red/green) of the display indicates this unmistakably. Critical process states or operational problems are reliably signalled. Converter for Industry 4.0 A special feature is the signal conversion: The threshold display converts analogue signals to digital IO-Link signals. Today they are required in almost any modern industrial environment and for Industry 4.0 applications.
  • 32. 33 (11.2016) Threshold display DP2200 Dimensions 31 24 3 30 M12x1 M12x1 63 1 2 1) Push ring 2) LEDs 3) Display Wiring diagram 43 2 1 3 1 2 4 5 M12: plug Pin 1: L+ supply Pin 2: OUT2 analogue output Pin 3: L- supply Pin 4: OUT1 switching output 1 or IO-Link M12: Buchse Pin 1: L+ sensor supply Pin 2: 4...20 mA analogue input Pin 3: L- sensor supply Pin 4: not used Pin 5: not used Typical plant configuration sensor parameter setting LINERECORDER sensor 4.0 IO-Link Threshold display with IO-Link USB adapter PLC 4...20 mA 4...20 mA industrial fieldbus 4...20 mA IO-Link master IP67 PLC industrial fieldbus IO-Link sensors without IO-Link ···1 7 8 M without IO-Link Operating voltage [V DC] 27 (typ. 24) Inputs 1 x analogue, 4...20 mA Ambient temperature [°C] -25...70 Protection IP 67 Output status indication LED yellow Operation LED green Wiring M12 connector Outputs 1 x digital / IO-Link, normaly open / closed programmable 1 x analogue, 4...20 mA Display 7-segment LED display 4-digit red/green programmable Technical data For further technical details please visit: www.ifm.com Accessories Type Description Order no. Mounting clip E89208 LINERECORDER SENSOR, Software for parameter setting and setting up IO-Link sensors QA0001 USB IO-Link master for parameter setting and analysis of units Supported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s) E30390
  • 33. 34 Sensors for motion control Multifunctional display: speed, time, counter Systems for pulse evaluation Clearly legible display 4 switching outputs and / or analogue output (V or mA) 250 kHz input frequency PNP, NPN or NAMUR inputs Touch display and clear text for intuitive handling Versatile pulse evaluation The multifunction display shows various measured values in industrial automation. It uses the principle of interval measurement to processes input pulses. The scaling factor allows (rotational) speed and processing time, etc., to be calculated, displayed and converted into an analogue signal. The unit can also act as a counter or an industrial timer. High performance Five different operating modes, optional analogue and switching outputs as well as the convenient display make the multifunctional evaluation system fit for various applications in industrial automation.
  • 34. 35 (11.2016) For further technical details please visit: www.ifm.com Dimensions Operating voltage [V] Inputs Inputs programmable Outputs Transistor Outputs Relay Order no. Multifunction display · touch display and clear text 24 DC 2 3 –– DX2031 24 DC 2 3 4V or mA DX2032 24 DC 2 3 4– DX2033 Operating voltage [V DC] 18...30 Current consumption [mA] approx. 150 (without load) Sensor supply [V DC] Output current UB -1 V max. 250 mA Incremental inputs Usage Format Frequency PNP, NPN, Namur encoders and sensors HTL (10...30 V) max. 250 kHz Control inputs Format Frequency HTL, PNP (10...30 V) max. 250 kHz Analogue output (only DX2032) Voltage output Current output Resolution Accuracy -10...10 V / 0...10 V 0...20 mA / 4...20 mA 16 bits ± 0.1 % Control outputs (DX2032 / DX2033) Format / level Output current 3...30 V (depending on the voltage on Com+), PNP max. 250 mA (max. 150 mA at Com+ <10 V) Display Type Colour Handling LCD (backlight) red, green, yellow (selectable) Touch screen (resistive) Ambient temperature [°C] -20...60 Dimensions (W x H x D) [mm] 96 x 48 x 100 Common technical data 48 96,2 115,3 114
  • 35. 36 Industrial imaging Augmented reality: mobile 3D smart camera with overlay function Camera systems for mobile machines 3D sensor system with inte- grated 2D camera and overlay function Indication of warnings and obstacles in the live view Signal processing in the sensor, no external process unit required Easy adjustment via ifm Vision Assistant Augmented reality The 3D smart camera is the first 3D sensor system with integrated 2D camera. The video image is displayed with real-time graphics, symbols or texts. They are either triggered by the integrated driver assistance system or by the machine controller via CAN. Thus, the user can always see all relevant warnings or other relevant details in the camera image. Integrated assistance system In addition to the 3D and 2D image sensor a complete evaluation system is integrated in the sensor system. This system provides an independent assistance system for collision avoidance for the user. Set-up only requires just a few steps using the ifm Vision Assistant PC software. In addition to the analogue video output the smart camera also features a CAN and Ethernet UDP interface. The system can use this interface to supply warnings in critical situations autonomously.
  • 36. 37 (11.2016) For further technical details please visit: www.ifm.com Further technical data O3M251 Housing material diecast aluminium PAL resolution [pixels] 640 x 480 Type of sensor 1/4" 4:3 VGA CMOS image sensor Color Connection M12 connector Protection rating, protection class IP 67 / IP 69K, III Operating voltage [V DC] 9...32 Current consumption sensor [mA] < 500 Current consumption [A] system illumination unit < 5 Ambient temperature [°C] -40...85 Interfaces 1x CAN, 1 x fast Ethernet, 1x PAL Storage temperature -40...105 Supported CAN protocols CANopen, SAE J 1939 Standards and tests (extract) CE, E1 (UN-ECE R10) Resolution [pixels] Angle of aperture horizontal x vertical [°] IlluminationAngle of aperture 2D [°] Order no. PMD 3D sensor · Type O3M · M12 connector 64 x 16 70 x 23 Ext. illumination required (O3M950) 90 O3M251 Max. sampling rate [Hz] 25/33/50 Accessories Type Description Order no. IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 70 x 23 O3M950 CAN/RS232 USB interface CANfox EC2112 Adapter cable set for CANfox EC2114 Operating software for vision sensors E3D300 U-shaped bracket, suitable for sensor or illumination E3M100 Weather protective cover (the article E3M100 or E3M102 is required for installation) E3M101 U-shaped bracket, suitable for sensor or illumination unit E3M102 Connection technology Type Description Order no. MCI cable, connection sensor / system illumination unit, 0,25 m E3M120 MCI cable, connection sensor / system illumination unit, 1 m E3M121 MCI cable, connection sensor / system illumination unit, 2 m E3M122 MCI cable, connection sensor / system illumination unit, 3 m E3M123 M12 video connection cable, connection sensor / display PDM360, 5 m E3M151 M12 video connection cable, connection sensor / display PDM360, 11 m E3M152 M12 video connection cable, connection sensor / display PDM360, 16 m E3M153 M12 video connection cable, connection sensor / display PDM360, 21 m E3M154 M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles E3M131 M12 socket, voltage supply system illumination unit, 5 m, PUR cable, 4 poles E3M132 M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles E3M133 Ethernet, cross-over patch cable, 2 m, PVC cable, M12 / RJ45 E11898 Ethernet, cross-over patch cable, 10 m, PVC cable, M12 / RJ45 E12204 Ethernet, cross-over patch cable, 20 m, PVC cable, M12 / RJ45 E12205 CAN jumper, screened, 2 m, PUR cable, M12 plug / M12 socket E11593 CAN jumper, screened, 5 m, PUR cable, M12 plug / M12 socket E11594 CAN jumper, screened, 10 m, PUR cable, M12 plug / M12 socket E11595 M12 video extension cable, 5 m E3M159 M12 video adapter cable / Cinch plug, for connection of a video grabber, 1 m E3M160
  • 37. 38 Industrial imaging Mobile 3D camera – 2D and 3D in one unit Camera systems for mobile machines Robust outdoor camera plat- form for innovative function development Synchronous output of 3D point cloud and live camera image Robust raw data, independent of ambient light and colour Video output (PAL) and Ethernet UDP High shock and vibration resistance Two images in one unit The O3M250 is the first 3D sensor system with integrated 2D camera for the output of a calibrated video image. In this context, calibrated means that the 2D image is superimposed on the 3D image. For external evaluation The camera system has been designed for system integrators and customers who intend to use 3D sensor data with their own algorithms in an external process unit. The image is sent as a PAL video image and the 3D point cloud is transmitted via Ethernet UDP. Easy setup ifm offers the Windows software “ifm Vision Assistant” for setup and parameter setting.
  • 38. 39 (11.2016) For further technical details please visit: www.ifm.com Further technical data O3M250 Housing material diecast aluminium PAL resolution [pixels] 640 x 480 Type of sensor 1/4" 4:3 VGA CMOS image sensor Color Connection M12 connector Protection rating, protection class IP 67 / IP 69K, III Operating voltage [V DC] 9...32 Current consumption sensor [mA] < 500 Current consumption [A] system illumination unit < 5 Ambient temperature [°C] -40...85 Interfaces 1 x fast Ethernet, 1x PAL Storage temperature [°C] -40...105 Standards and tests (extract) CE, E1 (UN-ECE R10) Accessories Connection technology Type Description Order no. Resolution [pixels] Angle of aperture horizontal x vertical [°] IlluminationAngle of aperture 2D [°] Order no. PMD 3D sensor · Type O3M · M12 connector 64 x 16 70 x 23 Ext. illumination required (O3M950) 90 O3M250 Max. sampling rate [Hz] 25/33/50 Type Description Order no. IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 70 x 23 O3M950 CAN/RS232 USB interface CANfox EC2112 Adapter cable set for CANfox EC2114 Operating software for vision sensors E3D300 U-shaped bracket, suitable for sensor or illumination E3M100 MCI cable, connection sensor / system illumination unit, 0,25 m E3M120 MCI cable, connection sensor / system illumination unit, 1 m E3M121 MCI cable, connection sensor / system illumination unit, 2 m E3M122 MCI cable, connection sensor / system illumination unit, 3 m E3M123 M12 video connection cable, connection sensor / display PDM360, 5 m E3M151 M12 video connection cable, connection sensor / display PDM360, 11 m E3M152 M12 video connection cable, connection sensor / display PDM360, 16 m E3M153 M12 video connection cable, connection sensor / display PDM360, 21 m E3M154 M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles E3M131 M12 socket, voltage supply system illumination unit, 5 m, PUR cable, 4 poles E3M132 M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles E3M133 Ethernet, cross-over patch cable, 2 m, PVC cable, M12 / RJ45 E11898 Ethernet, cross-over patch cable, 10 m, PVC cable, M12 / RJ45 E12204 Ethernet, cross-over patch cable, 20 m, PVC cable, M12 / RJ45 E12205 CAN jumper, screened, 2 m, PUR cable, M12 plug / M12 socket E11593 CAN jumper, screened, 5 m, PUR cable, M12 plug / M12 socket E11594 CAN jumper, screened, 10 m, PUR cable, M12 plug / M12 socket E11595 M12 video extension cable, 5 m E3M159 M12 video adapter cable / Cinch plug, for connection of a video grabber, 1 m E3M160 Weather protective cover (the article E3M100 or E3M102 is required for installation) E3M101 U-shaped bracket, suitable for sensor or illumination unit E3M102
  • 39. 40 Industrial imaging True 3D vision sensor with intelligent functions Camera systems for mobile machines Simple application solutions thanks to preprocessed 3D data Easy integration via predefined CODESYS function blocks Patented pmd time-of-flight technology for quick distance detection Optimised for reliable outdoor use with IP 67 and IP 69K Angle of aperture up to 95° Mobile 3D smart sensors O3M The 3D detection of scenes and objects, already a standard on the factory floor, is ready for mobile machines. Apart from new possibilities for vehicle automation (AGV, automatic guided vehicles) this results in new assistance functions for automation tasks. Different integrated functions configurable via the Windows software are available as standard. The simple connection of the 3D smart sensors is carried out via the CAN bus for mobile applications using the CANopen or SAE J 1939 protocol and/or via the fast Ethernet interface using UDP.
  • 40. 41 (04.2016) For further technical details please visit: www.ifm.com Description Order no. IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 70 x 23 O3M950 IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 95 x 32 O3M960 Further technical data Smart sensors O3M151, O3M161 Accessories Housing material diecast aluminium Device connection M12 connector Protection rating, protection class IP 67 / IP 69K, III Operating voltage [V DC] 9...32 Functions and advantages Powerful 3D time-of-flight measurement (ToF) The principle of these 3D sensors is based on ifm’s patented and award-winning pmd technology. It was specifically designed for outdoor use and difficult ambient light situations. Even interference such as sun- light or materials with different reflective characteristics do not influence the repeatability of the measured data. Powerful electronics The integrated 2 x 32-bit processor architecture ensures a rapid and reliable calculation of the 3D data and functions directly integrated in the system with up to 50 fps. The complete electronics of the mobile 3D smart sensor is optimised and adapted to the demands and requirements of mobile machines. Besides shock and vibration resistance self-diagnostic functions from the sensor to the IR system illumination unit are of course also available. Smart functions The mobile 3D smart sensors integrate some functions which enable a multitude of applications to be solved. A highly developed algorithm from the automotive industry is used ensuring, for example, reliable automatic object recognition of up to 20 objects. This function can, for example, be used as collision warning. For simple distance tasks typical functions such as minimum / maximum / average distance are available. System parameter setting and monitoring The parameter setting of the system and live monitoring of the 3D data are carried out via the easy-to-use ifm vision wizard for Windows. As an alternative, parameter setting can also be carried out via function blocks using the software CODESYS. Communication interfaces The preprocessed function data is output via the CAN bus using CANopen or SAE J 1939. If needed, the complete 3D information can be processed at the same time via Ethernet UDP and an external process unit. Current consumption sensor [mA] < 400 Current consumption [A] system illumination unit < 5 Ambient temperature [°C] -40...85 Interfaces 1x CAN, 1 x fast Ethernet Supported CAN protocols CANopen, SAE J 1939 Standards and tests (extract) CE, E1 (UN-ECE R10) CAN/RS232 USB interface CANfox EC2112 Adapter cable set for CANfox EC2114 Operating software for vision sensors E3D300 U-shaped holder, suitable for sensor or illumination unit E3M100 Connection technology MCI cable, connection sensor / system illumination unit, 1 m E3M121 MCI cable, connection sensor / system illumination unit, 2 m E3M122 Type Description Order no. M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles E3M131 M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles E3M133 Ethernet, cross-over patch cable, 2 m, PVC cable, M12 / RJ45 E11898 Ethernet, cross-over patch cable, 10 m, PVC cable, M12 / RJ45 E12204 Type of sensor Resolution pixels [pixel] IlluminationAngle of aperture horizontal x vertical [°] Order no. PMD 3D sensor · Type O3M · M12 connector PMD 3D chip 64 x 16 ext. illumination required (O3M950) 70 x 23 O3M151 Max. sampling rate [Hz] 25/33/50 PMD 3D chip 64 x 16 ext. illumination required (O3M960) 95 x 32 O3M16125/33/50
  • 41. 42 Industrial imaging 3D sensors for mobile machines Camera systems for mobile machines Support for system integrators with data output via Ethernet UDP Patented pmd time-of-flight technology for quick distance detection Optimised for reliable outdoor use Robust design with IP 67 and IP 69K Angle of aperture up to 95° Mobile 3D sensors O3M The 3D detection of scenes and objects, already a standard on the factory floor, is ready for mobile machines. Apart from new possibilities for vehicle automation (AGV, automatic guided vehicles) this results in new assistance functions for automation tasks. Besides position data at pixel level the respective distance to the sensor system or an adjustable reference point (world coordinate system) is provided. Thanks to the permanent output of the entire 3D information via Ethernet UDP optimum conditions for customer-specific application solutions are provided to system integrators.
  • 42. 43 (04.2016) For further technical details please visit: www.ifm.com Further technical data O3M150, O3M160 Housing material diecast aluminium Device connection M12 connector Protection rating, protection class IP 67 / IP 69K, III Operating voltage [V DC] 9...32 Functions and advantages Powerful 3D time-of-flight measurement (ToF) The principle of these 3D sensors is based on ifm’s patented and award-winning pmd technology. It was specifically designed for outdoor use and difficult ambient light situations. Interference such as sunlight or materials with different reflective characteristics which occurs in the area of mobile machines does not influence the repeatability of the measured data. Powerful electronics The integrated 2 x 32-bit processor architecture ensures a rapid and reliable calculation of the distance image to be output with up to 50 fps. The complete electronics of the mobile 3D sensor is optimised and adapted to the demands and requirements of mobile machines. Besides shock and vibration resistance self-diagnostic functions from the sensor to the IR system illumination unit are of course also available. High system uptime The system has various features to ensure uninterrupted operation. They include, among others, soiling indication as well as different status information which can be fetched from CAN. System parameter setting and monitoring The parameter setting of the system and live monitoring of the 3D data are carried out via the easy-to-use ifm vision wizard for Windows. Communication interfaces The mobile 3D sensors feature a fast Ethernet interface (100 Mbit) as well as a CAN interface. The data output of the complete 3D information is carried out via Ethernet UDP and can be processed using a process unit at the customer’s end. For this version the CAN in- terface is only intended for parameter setting and status output. Current consumption sensor [mA] < 400 Current consumption [A] system illumination unit < 5 Ambient temperature [°C] -40...85 Interfaces 1x CAN, 1 x fast Ethernet Connection technology MCI cable, connection sensor / system illumination unit, 1 m E3M121 MCI cable, connection sensor / system illumination unit, 2 m E3M122 Type Description Order no. M12 socket, voltage supply system illumination unit, 2 m, PUR cable, 4 poles E3M131 M12 socket, voltage supply system illumination unit, 10 m, PUR cable, 4 poles E3M133 Ethernet, cross-over patch cable, 2 m, PVC cable, M12 / RJ45 E11898 Ethernet, cross-over patch cable, 10 m, PVC cable, M12 / RJ45 E12204 Type of sensor Resolution pixels [pixel] IlluminationAngle of aperture horizontal x vertical [°] Order no. PMD 3D sensor · Type O3M · M12 connector PMD 3D chip 64 x 16 ext. illumination required (O3M950) 70 x 23 O3M150 Max. sampling rate [Hz] 25/33/50 PMD 3D chip 64 x 16 ext. illumination required (O3M960) 95 x 32 O3M16025/33/50 Description Order no. IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 70 x 23 O3M950 IR system illumination unit (850 nm) for mobile 3D sensors, angle of aperture 95 x 32 O3M960 Accessories Supported CAN protocols CANopen, SAE J 1939 Standards and tests (extract) CE, E1 (UN-ECE R10) CAN/RS232 USB interface CANfox EC2112 Adapter cable set for CANfox EC2114 Operating software for vision sensors E3D300 U-shaped holder, suitable for sensor or illumination unit E3M100
  • 43. 44 Industrial imaging MultiViewBox: display up to 4 camera images on one screen Camera systems for mobile machines Video splitter for up to four camera images 9 different display modes (incl. bird’s eye view) Analogue video output (PAL) Shock and vibration resistant, potted stainless steel housing E4 type approval, optimised for use in mobile machines Suitable camera images in every situation The multi-view box has been designed for use in mobile machines in harsh environments. It features four camera inputs. Depending on the require- ments, 1, 2 or 4 camera images can be selected simultaneously in different arrangements via one control input. For example: Cam1 when moving for- wards and Cam2 and 3 when moving backwards. In the “bird’s eye view” 4 camera images can even be combined to become one 360° view. A total of 9 different display modes are available for the user. Analogue video output The ifm PDM360 dialogue module with analogue video input which is also suitable for mobile use or any other video display with PAL video input can be used as display.
  • 44. 45 (11.2016) For further technical details please visit: www.ifm.com Connection technology Type Description Order no. Connection cable, M16, 3,85 m, 8 poles, for the voltage supply of the E2M250 multi-view box, open cable end E2M251 Socket, M16, wirable 8 poles, for the voltage supply of the E2M250 multi-view box E2M252 Adapter cable, 0.6 m black, PUR cable, M12 connector / M16 socket, to connect the MultiViewBox to the PDM NG E2M200 Jumper, 5 m black, PUR cable, M16 plug / M16 socket E2M203 Jumper, 11 m black, PUR cable, M16 plug / M16 socket E2M204 Jumper, 16 m black, PUR cable, M16 plug / M16 socket E2M205 Jumper, 21 m black, PUR cable, M16 plug / M16 socket E2M206 Current consumption [mA] < 1200 Video signal PAL (25 fps, interlacing) 720H x 576V (active 680 x 480) Ambient temperature [°C] -40...85 Protection IP 67 (ISO 20653) Approval UN-ECE R10 Housing materials stainless steel SS316 (1.4401) Connection M16 connector MultiViewBox E2M250 Technical data Operating voltage [V DC] 10...32 DC Products Order no. Video splitter, visualisation of up to 4 camera images (PAL) on one process and dialogue mo- dule E2M250 Type Description Angle of aperture 78°, lens heating O2M200 Angle of aperture 78°, lens heating, integrated mirror function O2M201 Angle of aperture 115°, lens heating O2M202 Angle of aperture 115°, lens heating, integrated mirror function O2M203 MultiViewBox Analogue camera, 0.5 m connection cable with M16 connector Dimensions 180 160 113,5 100 73 85 1,5 40 1 2 3 4 5 6 1) INPUT 2) OUTPUT 3) C4 4) C3 5) C2 6) C1
  • 45. 46 Industrial imaging Photoelectric 3D level measurement and point level detection 3D sensors Continuous measurement of uneven surfaces Determines min, max or mean values Teaching of different tank shapes Interfering structures are suppressed Non-contact detection of opaque media for levels of up to 10 m Flexible configuration The system detects solid, opaque solids and bulk materials in tanks, silos or hoppers with levels of up to 10 m. The O3D reliably detects the load height in machinery for mechanical handling, e.g. belts, and the loading of pallets. The sensor determines the level via a defined background and transmits the process value via analogue output or digitally and noise immune via the Ethernet process interface. Alternatively, the O3D may be used as a point level switch. The measuring segment of the sensor can be adapted to the shape of the respective tank. Agitators and other attachments can be suppressed via “exclusion regions”. Various container shapes, such as hoppers, silos or even inclined belts can be recognised by the sensor. This means that for bulk materials the average level is indicated, even if there are conical heaps or funnelling.
  • 46. 47 (11.2016) For further technical details please visit: www.ifm.com Mounting set for O3D E3D301 Further technical data Accessories Operating voltage [V DC] 20.4...28.8 Current consumption [mA] < 2400 peak current pulsed; typ. mean value 420 Current rating [mA] (per switching output) 100 Real chip resolution 25,000 / 100,000 Resulting resolution 176 x 132 pixels Function display LED 2 x yellow, 2 x green Illumination 850 nm, infrared Ambient light [lux] max. 10,000 (indoor) Trigger external; 24 V PNP / NPN according to IEC 61131-2 type 3 Switching inputs 2 (configurable), 24 V PNP/NPN according to IEC 61131-2 type 3 Switching outputs digital 3 (configurable), 24 V PNP/NPN, according to IEC 61131-2 Switching outputs analogue 1 (can be configured as current output 4...20 mA or voltage output 0...10 V) Ambient temperature [°C] -10...50 Ethernet, cross-over patch cable, 2 m, PVC cable, M12 / RJ45 E11898 Ethernet, jumper cables, 2 m, PVC cable, M12 / M12 E21138 Type of sensor Material front pane / LED window Angle of aperture [°] Protection rating, protection class Order no. PMD 3D sensors · Type O3D · M12 connector PMD 3D ToF chip Gorilla glass / polyamide Material housing Aluminium 40 x 30 IP 65 / IP 67, III O3D300 Max. field of view size [m] 2.61 x 3.47 PMD 3D ToF chip Gorilla glass / polyamide Aluminium 60 x 45 IP 65 / IP 67, III O3D3023.75 x 5.00 PMD 3D ToF chip Polycarbonate / polyamide Stainless steel 40 x 30 IP 65, IP 67, IP 69K / III O3D3102.61 x 3.47 PMD 3D ToF chip Polycarbonate / polyamide Stainless steel 60 x 45 IP 65, IP 67, IP 69K / III O3D3123.75 x 5.00 Socket, M12, 2 m black, PUR cable, 8 poles E11950 Type Description Order no. Cooling element E3D302 Double cooling element E3D304 Heat conductor E3D303 Short-circuit protection, pulsed • Overload protection • Parameter setting interface Ethernet 10 Base-T / 100 Base-TX Possible parameter settings via PC / notebook Dimensions (H, W, D) [mm] 72 x 65 x 85 Technical data Level measurement and point level detection Typ. level [m] 0.3...6 Operating distance max. [m] 10 Sampling rate [Hz] 5 Mounting accessories Connection technology
  • 47. 48 Process sensors Pressure transmitters with DEUTSCH, AMP or M12 connector for mobile applications Pressure sensors Compact design (AF19) with process connection G 1/4 male Fast reaction: 2 milliseconds response time Measuring accuracy < ± 0.8 %, repeatability < ± 0.05 % Easy connection via DEUTSCH, AMP or M12 connector Robust low-cost solution with welded stainless steel housing Miniaturisation for mobile applications The connectors of the new PT/PU pressure sensors allow fast and easy installation in mobile machines. The sensors also feature a thin-film measuring cell directly welded with the process connection. This technology guarantees high accuracy in a very compact housing with only 19 mm across flats at a cost-optimised price/performance ratio. Applications The PT/PU type sensors are suited for mobile applications and especially for hydraulic and pneumatic applications with high operating pressure. The high vibration and shock resistance, the high protection rating, the excellent EMC resistance and the E1 conformity make the PT/PU sensors particularly suitable for use in mobile machines.
  • 48. 49 (04.2016) For further technical details please visit: www.ifm.com Accessories Type Description Order no. Operating voltage PT [V DC] PU [V DC] 8...32 16...32 Common technical data Medium temperature [°C] -40...125 Materials wetted parts 1.4542 (17-4 PH / 630), characteristics similar to stainless steel (e.g. 304/1.4301) but higher strength Protection IP 67 / IP 69K Step response time [ms] 2 Restrictor • EMC Compliant with UN-ECE10 Rev. 4 ISO 11452: 100 V/m EN61326 Reverse polarity protection • Adapters; G 1/4 - G 1/2, high-grade stainless steel (316Ti/1.4571) E30135 Accuracy / deviation (in % of the span) Linearity error Linearity Hysteresis Repeatability Long-term stability Temperature coefficients (TEMPCO) in the temperature range 0 ... 80 °C (in % of the span per 10 K) TEMPCO of zero TEMPCO of the span Temperature coefficients (TEMPCO) in the temperature ranges -40...0 °C and 80...125 °C (in % of the span per 10 K) TEMPCO of zero TEMPCO of the span < ± 0.8 < ± 0.25 BFSL / < ± 0.5 LS < ± 0.2 < ± 0.05 < ± 0.1 < ± 0.1 < ± 0.1 < ± 0.2 < ± 0.2 Wiring diagram Dimensions 12 65,9 51,6 M12x1 18,9 G 1 4 / 19 1 Example: type PT55 1) HNBR seal / DIN 3869 PU5704 PU5703 PU5702 PU5701 PU5700 PU5760 PU5604 PU5603 PU5602 PU5601 PU5600 PU5660 Measuring range relative pressure [bar] Poverload max. [bar] Pburst min. [bar] Output function 4…20 mA, 0...10 25 300 0...25 65 600 0...100 250 1000 PT5702 0...250 625 1200 PT5701 0...400 1000 1700 PT5700 0...600 1500 2400 PT5760 Output function 0...10 V 0...10 300 0...25 600 0...100 1000 PT5602 0...250 1200 PT5601 0...400 1700 PT5600 0...600 2400 PT5660 PT5502 PT5501 PT5500 PT5560 25 65 250 625 1000 1500 Order no. PT5504 M12 connector PT5503 Order no. PT5604 AMP connector PT5603 Order no. PT5704 DEUTSCH connector M12 connector AMP connector DEUTSCH connector PT5703 L+ BN1 WH2 OUT Type PT55 1 2 3 OUT L + L - Type PU56 A B OUT +L A C B OUT L - L +L + Type PU57Type PT57 1 3 L + OUT Type PT56 – – – – – –
  • 49. 50 Process sensors Hydrostatic level measurement for a wide range of applications Pressure sensors High-grade stainless steel submersible pressure transmitter with PUR or FEP cable for high resistance to media Version with ATEX approval for group I cat. M1 and group II cat. 1G and 1D. Good overall accuracy and long-term stability Pressure compensation via internally vented cable Application areas The PS series submersible pressure transmitters are used for level measurement in containers, tanks, wells, flowing water, bore holes and wastewater plants. The accuracy of 0.5 % and the long-term stability of 0.2 % per year contribute to the reliable operation of the transmitter. Robust, reliable and flexible All submersible pressure transmitters have a robust high-grade stainless steel housing. For standard applications the favourably priced PUR cable can be used. For applications where a high resistance to media is requested (e.g. slurry, oils or fuels) the FEP cable is available. The ATEX submersible pressure transmitters of the PS3xxA series are designed for level measurement in areas subject to explosion. The sensors can be used in zone 0, 1, 2 or zone 20, 21, 22 as well as in mining. The GL approval allows an application in the maritime sector.
  • 50. 51 (04.2016) For further technical details please visit: www.ifm.com Splitter box * with vent and terminal block E30401 Additional weight, approx. 500 g E30402 Filter element * E30400 Cable fixing clamps * E30399 Submersible pressure transmitters with PUR cable for standard applications 0.6 0.6 0.6 4 4 4 1000 N 1000 N 1000 N Measuring range Relative pressure [bar] Approvals CE / EX / GL Overload pressure [bar] Pull force cable 1 1 5 5 1000 N 1000 N Cable length [m] PS3407 PS3427 PS3607 Order no. PS3417 PS3617 0.25 2 1000 N 10 15 30 15 30 5 • / – / – • / – / – • / – / – • / – / – • / – / – • / – / – PS3208 Operating voltage [V DC] 18...30 Analogue output [mA] 4...20 Accuracy / deviation (in % of the span) Accuracy (BFSL) Accuracy incl. non-linearity Non-linearity (BFSL) Long-term stability per year ≤ 0.25 (PS3: 0.5) ≤ 0.5 (PS3: 1) ≤ 0.2 ≤ 0.2 Design PS3 Ambient temperature / [°C] Medium temperature -10...50 Design PS4 Ambient temperature / [°C] Medium temperature -10...85 Design PS3 ATEX approval Ambient temperature / [°C] Medium temperature 1G, 1/2G, 2G: T6 -10...60, T5: -10...80, T4: -10...85 1D, 1/2D, 2D: -10...40 (750 mW) / - 10...70 (650 mW) / - 10...85 (550 mW) Housing material High-grade stainless steel (316Ti / 1.4571) Further technical data Accessories Type Description Order no. * use only outside the hazardous area Submersible pressure transmitters with FEP cable for high resistance to media 0.6 1 3 5 500 N 500 N PS4407 PS4417 0.25 2 500 N 10 15 5 • / – / – • / – / – • / – / – PS4208 Submersible pressure transmitters with FEP cable for hazardous areas 0.6 1 4 5 500 N 500 N PS307A PS317A 0.25 2 500 N 10 15 5 • / • / • • / • / • • / • / • PS308A Temperature coefficients (TEMPCO) (in % of the span per 10 K) Greatest TEMPCO of zero Greatest TEMPCO of the span ≤ 0.2 ≤ 0.2 100 27 Example PS3208 Dimensions 0.6 1 3 5 500 N 500 N PS4506 PS4607 0.25 2 500 N 20 30 10 • / – / – • / – / – • / – / – PS4408
  • 51. 52 Process sensors New PT absolute pressure transmitter with different measuring ranges Pressure sensors Measuring range 0...1/1.6/4/ 10 bar absolute and analogue output 4...20 mA Robust stainless steel measuring cell Slim, compact design with G 1/4 process connection Measuring accuracy ≤ 0.8 %, repeatability ≤ 0.1 % Easy connection via M12 connector Absolute pressure sensors As of now, ifm has added absolute pressure sensors to its versatile portfolio in the pressure sensor range. The new PT05 series with robust metal measuring cell, G 1/4 process connection, M12 connector and analogue output is available in the common pressure ranges up to 10 bar. Operating principle Absolute pressure sensors operate independently of the surrounding air pressure; that is what distinguishes them from sensors working on a relative measurement principle. The measurement is not influenced by weather- and altitude-related fluctuations of air pressure. This is often a decisive factor in vacuum applications, which require a fine pressure control. Absolute pressure sensors do not require ventilation, therefore incorrect measurement due to a blocked exhaust is impossible. In the field of pressure sensors the new units stand out as specialists for ”specific duties“.
  • 52. 53 (04.2016) For further technical details please visit: www.ifm.com Accessories Type Description Order no. Operating voltage [V DC] 8...30 Common technical data Medium temperature [°C] 0...80 Materials (wetted parts) NBR, high-grade stainless steel (316L/1.4404) Protection IP 67 Step response time [ms] 4 Reverse polarity protection • Adapter; G 1/4 - G 1/2, high-grade stainless steel (316Ti/1.4571) E30135 Measuring range [bar] Poverload max. [bar] Pburst min. [bar] Order no. Output function 4...20 mA 0...1 5 PT0507 0...1.6 10 PT0517 0...4 25 PT0505 0...10 50 PT0504 Accuracy / deviation (in % of the span) Linearity error Linearity Repeatability Temperature error in the temperature range 0...80 °C < ± 1.0 < ± 0.5 BFSL / < ± 1.0 LS < ± 0.1 < ± 2.5 % Connection technology Type Description Order no. M12 socket, 2 m black, PUR cable EVC001 M12 socket, 5 m black, PUR cable EVC002 M12 socket, 2 m black, PUR cable EVC004 M12 socket, 5 m black, PUR cable EVC005 L+ BN1 WH2 OUT Wiring diagram Dimensions 14 47 58,8 G¼ 29 M12x1 27 1 1) Sealing 2 3.2 8 20
  • 53. 54 Process sensors IO-Link display: process values at a glance IO-Link display Four measured values / text displays and four message windows for free text Colour change for text and background Flexible adaptation of the display, also during operation IO-Link 1.1 compatible Easy integration into each IO-Link structure More plant transparency The IO-Link display is a flexible solution to display process values, texts and messages in a plant. It displays up to four assigned process values, alarms and warnings. Clear text and as an option a colour change of text and background can be used for a quick overview. By means of buttons the user can trigger control actions of the PLC or acknowledge messages. Easy integration The IO-Link display is connected to an IO-Link master and controlled via PLC. No special software is required for configuration. Texts and settings can be predetermined via an IO-Link device tool such as LINERECORDER SENSOR. Texts and settings can be adapted even during operation via the PLC.
  • 54. 55 (04.2016) For further technical details please visit: www.ifm.com Resolution pixels Display type Display illumination Order no. 1.44" colour display 128 x 128 TFT LED E30391 Wiring Dimensions Technical data IO-Link display E30391 Operating voltage [V DC] 18...30 Current consumption [mA] < 47 Protection rating / protection class IP 65, IP 67 / III Reverse polarity protection • Ambient temperature [°C] 0...60 EMC EN 61000-6-2 EN 61000-6-4 Shock resistance [g] 20 (11 ms) Vibration resistance [g] 20 (10...50 Hz) Housing materials Stainless steel (303/1.4305); PC; PBT-GF 30; PPS; PA 6.6; FKM Connection M12 connector Communication interface IO-Link device Type of transmission IO-Link revision SDCI standard COM2 (38.4 kbaud) 1.1 IEC 61131-9 Connection technology Type Description Order no. M12 jumper 1 m black, PUR cable EVC042 M12 jumper 2 m black, PUR cable EVC043 M12 jumper, 3 m black, PUR cable EVC102 M12 jumper, 5 m black, PUR cable EVC044 M12 jumper, 10 m black, PUR cable EVC493 BN1 BK4 BU3 L+ L OUT 45 34 86 101 39,5 11 M12x1 Accessories Type Description Order no. DIN rail clip, PA; 1.4567 (V2A) E30429
  • 55. 56 Process sensors Calorimetric flow meter for liquids and gases Flow sensors / flow meters Optimised for water, oils, glycol and air Fast response time and integrated temperature measurement Red/green colour change for process values Internal pipe diameter selectable from 15...400 mm The process connection can be rotated for optimum alignment Measurement technique The SA volumetric flow sensor operates using the calorimetric measuring principle. Measuring elements as well as a heat source are located on the measuring tip. The physical effect that a flowing medium absorbs heat energy and conducts it away is used. The resulting temperature change is an indication of flow. Device function The new SA-type sensor has been designed to detect and measure flow and temperature even in large internal pipe diameters up to 400 mm. A serial number on the device enables unambiguous traceability. Therefore it serves different applications. Switching outputs, analogue signals and IO-Link provide various options to further process the signals. That means that the user is best-equipped for Industry 4.0.
  • 56. 57 (04.2016) For further technical details please visit: www.ifm.com Common technical data Operating voltage [V] 18...30 DC Current consumption [mA] < 100 Current rating [mA] 250 Housing materials High grade stainless steel (1.4404/316L); PBT-GF 20; PBT-GF 30 Connection M12 connector Accuracy temperature measurement ± 0.3 K Type SA Protection rating, protection class IP 65 / IP 67, III BN WH BK BU 4 1 3 2 OUT2 L+ L OUT1 Wiring Measuring range liquid / gaseous [cm/s] Medium temperature [°C] Response time [s] Order no. M12 connector · electrical design DC PNP 5...300 / 200...10000 -20...90 0.5 SA5000 Probe length [mm] 45 5...300 / 200...10000 -20...100 0.5 SA4100100 5...300 / 200...10000 -20...100 0.5 SA4300200 Pressure resistance [bar] 100 50 50 Type M18 Progressive ring Progressive ring Connection technology Type Description Order no. M12 socket, 2 m black, PUR cable EVC001 M12 socket, 5 m black, PUR cable EVC002 M12 socket, 2 m black, PUR cable EVC004 M12 socket, 5 m black, PUR cable EVC005 M12 socket, 2 m orange, PVC cable EVT064 M12 socket, 5 m orange, PVC cable EVT001 Accuracy flow measurement ± (5 % MW + 2 % VMR) at reference conditions Accessories Type Description Order no. Progressive ring fitting G 1/2, flat seal E40258 Progressive ring fitting G 1/4, flat seal E40259 Progressive ring fitting G 3/4, flat seal E40260 USB IO-Link master for parameter setting and analysis of units Supported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s) E30390 Progressive ring fitting 1/2 NPT E40261 Progressive ring fitting 1/4 NPT E40262 Progressive ring fitting R 1/2 E40263 Progressive ring fitting R 1/4 E40264 Progressive ring fitting for SL mounting adapter E40269 Protective cover for fluid sensors with M12 connector, polypropylene homopolymer E30420 Welding adapter for cutting ring E40265 Flow adapter E40434 Progressive ring fitting G 1/2, metal to metal seal E40267 Progressive ring fitting G 3/4 metal to metal seal E40268
  • 57. 58 Process sensors Two temperature sensors in one Temperature sensors Two in one: process values plus two switched outputs Measuring range -50...150 °C IO-Link for simple, remote setting Extremely high accuracy of +/- 0.3 K Tamper-proof Flexible in use The functionality of the temperature sensor TV is impressive. Due to its extremely compact design the TV sensor can be installed where space is at a premium. The device has two switch points, operates with an extremely high precision and can be set easily and quickly via the LINERECORDER SENSOR. Efficient and reliable thanks to IO-Link Thanks to IO-Link the new temperature sensor continuously transmits process values and other important data, e.g. min. / max. temperature. Moreover, the digital measurement results are more accurate because there are no conversion losses by D/A converters or external influences (e.g. cable lengths). Devices with preset measuring ranges (analogue start and end points) are no longer needed because the real process value is transmitted. This reduces stock. Soon conventional transmitters will be a thing of the past.
  • 58. 59 (11.2016) For further technical details please visit: www.ifm.com IO-Link interface for parameter setting and analysis of units with DTM specification, current consumption from USB port: max. 500 mA E30396 Memory plug, parameter memory for IO-Link sensors E30398 LINERECORDER SENSOR, software for parameter setting and setting up IO-Link sensors QA0001 IO-Link accessories Type Description Order no. Connection technology Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Operating voltage [V DC] 18...32 Protection rating protection class IP 69K, lll Materials wetted parts high-grade stainless steel (316L/1.4404) Further technical data Reverse polarity / overload protection • / • Dynamic response T05 / T09 1 s / 3 s Accuracy [K] ± 0.3 Measuring range [°C] -50...150 Ambient temperature [°C] -25...80 IO-Link revision 1.1 Dimensions Wiring diagram Example TV7105 Example TV7603 Installation length [mm] Order no. Pressure rating [bar] Output function 2 x NO / NC programmable, measuring range -50...150 °C 25 400 30 300 25 400 30 Process connection G 1/4 G 1/2 1/4" NPT 1/2" NPT 300 TV7105 TV7405 TV7603 TV7303 Example TV7105 6 M12x1 18,7 15,9 48 19 13 G ¼ 25 BN WH BK BU 4 1 3 2 OUT2 L+ L OUT1 6 M12x1 18,7 15,9 48 71 19 ¼" NPT 25
  • 59. 60 Process sensors Temperature sensor with easy dial setting Temperature sensors Measuring range -25...140 °C Two switching outputs Easy adjustment via two setting rings for optimum read-out Mechanical lock to prevent accidental adjustment Accuracy: ± 3 K Convenient and reliable setting The TK type temperature sensors are sensors to monitor liquids and gases with switch points that can be set intuitively via two radial setting rings. Wherever simple solutions are needed, the TK series sensors are a real alternative. Complicated parameter setting via software is not necessary. The requested temperature is set via the setting rings allowing optimum read-out without your installation having to be in operation. In addition, the switching states are clearly displayed via LEDs. Versions The sensors are available with a setpoint and a reset point (TK6xxx) or two switch points with a fixed hysteresis (TK7xxx). The TK series temperature sensors are always the optimum choice for quick and simple use.
  • 60. 61 (11.2016) For further technical details please visit: www.ifm.com Dimensions M12x1 27 6 G ¼ 59 50 12 27LED Example TK6110 Dynamic response T05 / T09 [s] 1 / 3 Accuracy Setting accuracy [K] Temperature influence (per 10 K) Repeatability [K] ± 3 0.1 ± 0.1 Ambient temperature [°C] -40...70 Shock resistance 50 g Vibration resistance 20 g Housing materials high-grade stainless steel (316L/1.4404), PC (Makrolon), PBT (Pocan), FPM (Viton) Materials wetted parts high-grade stainless steel (316L/1.4404), FPM (Viton) Connection M12 connector Protection rating, protection class IP 67 / III Operating voltage [V DC] 9.6...32 Current rating [mA] 500 Further technical data Measuring range [°C / °F] Order no. M12 connector, gold-plated contacts · output function normally open / normally closed complementary TK6110-25…140 / -13...284 Process connection G 1/4 Installation length [mm] 50 Switching hysteresis [K] adjustable Pressure rating [bar] 400 TK6310-25…140 / -13...284 1/4 NPT 50 adjustable 400 M12 connector, gold-plated contacts · output function 2 x normally open TK7110-25…140 / -13...284 G 1/4 50 5 (fixed) 400 M12 connector, gold-plated contacts · output function 1 x normally open / 1 x normally closed TK7460-25…140 / -13...284 G 1/2 250 5 (fixed) 300 Adapter, G 1/4 – G 1/2 high-grade stainless steel (316Ti/1.4571) E30135 Protective cover with lead seal option for TK type temperature sensors, PP transparent E30094 Accessories Type Description Order no. Flange adapter G1/4, stainless steel (303/1.4305) E30063 Thermowells G 1/4 E377002750 Screw-in thermowell, process connection G 1/4 G 1/2 E37640224250 Screw-in thermowell, process connection G 1/2 Device connection Installation length [mm] Sensor Thermowell Order no. Connection technology Type Description Order no. Socket, M12, 2 m black, PUR cable EVC001 Socket, M12, 5 m black, PUR cable EVC002 Socket, M12, 2 m black, PUR cable EVC004 Socket, M12, 5 m black, PUR cable EVC005 Socket, M12, 2 m black, PUR cable, LED EVC007 Socket, M12, 5 m black, PUR cable, LED EVC008
  • 61. 62 Temperature sensors TN sensor with integrated process connection and eva- luation electronics Measuring range of -50...150 °C, response time T05 / T09 = 1s / 3s. Clearly indicates the acceptable ranges: programmable red / green display Integrated process connections: G 1/2, G 1/4, 1/2 NPT, 1/4 NPT, M18 x 1.5 2 switching outputs or 1 switching and 1 analogue output (4...20 mA or 0...10 V) Visualisation of the switching states by clearly visible LEDs Extremely fast, robust and flexible The compact TN type temperature sensors are distinguished by excellent response times, high pressure resistance and integrated process connections. The sensors easily resist applications with temperatures up to 150 °C and high pressure loads up to 400 bar. The measuring range is freely scalable. Updating a classic What is new is the quick and easy handling via three pushbuttons. The display can be switched from the indication of ”red“ to an alternating indication of “red - green“. So, switching states can be highlighted or an independent colour window can be created. The sensor head can be rotated and offers optimum readability from any position. Thanks to captive laser labelling on the stainless steel housing, the units can still be identified after years. Process sensors
  • 62. 63 (04.2016) For further technical details please visit: www.ifm.com Adapter, M18 x 1.5 - G 1/2 High-grade stainless steel (316L/1.4404) E40096 Protective cover for fluid sensors with M12 connector, polypropylene homopolymer E30420 Accessories Type Description Order no. Accuracy [K] ± 0.3 + (± 0.1 % MS) Electrical design PNP / NPN Protection IP 67 Communication interface IO-Link Resolution display [K] 0.1 Operating voltage [V] 18...32 DC Current rating [mA] 250 Further technical data IO-Link interface for parameter setting and analysis of units with DTM specification, current consumption from USB port: max. 500 mA E30396 Memory plug, parameter memory for IO-Link sensors E30398 LINERECORDER SENSOR, software for parameter setting and setting up IO-Link sensors QA0001 IO-Link accessories Type Description Order no. USB IO-Link master for parameter setting and analysis of units Supported communication protocols: IO-Link (4.8, 38.4 and 230 Kbits/s) E30390 1) LEDs (display unit / switching status), 2) 4-digit alphanumeric display / alternating indication of red and green, 3) Programming buttons, 4) Upper part of the housing can be rotated by 345° Installation length [mm] Pressure resistance [bar] 300 45 Measuring range [°C] Factory setting [°C] Order no. Output function 1 x NO / NC programmable · 1 x analogue output 4…20 mA or 0…10 V programmable -50...150 -40...150 Process connection M18 x 1.5 I TN2511 300 45 Output function 2 x NO / NC programmable -50...150 -40...150M18 x 1.5 I TN7511 300 30 -50...150G 1/2 TN2405 300 50 -50...150G 1/2 TN2415 160 100 -50...150G 1/2 TN2435 160 150 -50...150G 1/2 TN2445 300 30 -50...1501/2" NPT TN2303 300 50 -50...1501/2" NPT TN2313 160 100 -50...1501/2" NPT TN2333 160 150 -50...1501/2" NPT TN2343 400 25 -50...150G 1/4 TN2105 400 50 -50...150G 1/4 TN2115 400 25 -50...1501/4" NPT TN2603 400 50 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...150 -50...1501/4" NPT TN2613 Output function 2 x NO / NC programmable or 1 x NO / NC + 1 x analogue (4...20 mA / 0...10 V; scalable) Response dynamics T05 / T09 [s] 1 / 3 Thermowell for temperature sensors, Ø 6 mm, high-grade stainless steel (316L/1.4404) E37610 Dimensions 48 M12x1 22 EL11 41 34 80 121 4 3 2 1 G ¼ 6 Example 2105
  • 63. 64 Temperature sensors Temperature sensors with DEUTSCH, AMP or M12 connector Miniaturisation for mobile applications The DEUTSCH, AMP or M12 connectors of the new TA/TU/TM temperature sensors allow fast and easy installation in mobile machines. Their extremely compact housing ensures that the sensors are particularly suited for use in applications where space is limited. Areas of application The sensors of type TA/TU/TM are suited for mobile applications and especially for hydraulic and pneumatic applications with high operating pressure. The high vibration and shock resistance, the high protection rating, the excellent EMC resistance and the E1 conformity make the TA/TU/TM sensors particularly suitable for use in mobile machines. Process sensors Compact design with G 1/4 process connection Fast response time: T05 / T09 = 1 s / 3 s Installation depths of 25...200 mm Measuring range -50...150 °C Robust due to welded stainless steel housing
  • 64. 65 (04.2016) For further technical details please visit: www.ifm.com Installation length [mm] Order no. Factory setting Connector G 1/4 process connection Analogue output 4...20 mA 25 M12 50 M12 200 M12 25 DEUTSCH G 1/4 process connection Analogue output 0.5...4.5 V 25 M12 25 DEUTSCH 25 AMP Operating voltage [V DC] Type TA 10...30 Operating voltage [V DC] Type TU 8...32 Protection rating IP 68, IP 69K / lll Materials in contact with the medium High-grade stainless steel (316L/1.4404) Further technical data Reverse polarity / overload protection • / • Response dynamics T05 / T09 1 s / 3 s Ambient temperature [°C] -40...100 EMC DIN EN 61000-6-2 DIN EN 61000-6-3 Dimensions TA3105 TA3115 TA3155 TA4105 50 DEUTSCH TA4115 25 AMP TA5105 50 AMP TA5115 TU3105 TU4105 TU5105 -50...150 °C -50...150 °C G 1/4 process connection Pt1000, class A 25 M12 25 DEUTSCH TM5101 TM6101 -40...150 °C 1/4" NPT process connection Analogue output 4...20 mA 50 M12 50 M12 TA3313 TA3317 0...300 °F / 0...100 °C Wiring M12x1 18,8 6 55,3 13 EL 19 G ¼ TA31 21,8 6 25,4 EL 1359,6 19 G ¼ TA41 25,8 6 EL 1359,8 19 G ¼ 21,8 TA51 L+ BN1 WH2 OUT BN1 WH2 BU3 L+ L OUT TU31TA31 A C B OUT L - L +L + TU41 1 3 L + OUT 1 2 3 OUT L + L - TU51TA51 A B OUT +L TA41
  • 65. 66 Industrial communication DataLine SmartPLC: flexible automation system AS-Interface controllers / gateways Quick and easy set-up Flexible and future-proof thanks to connective hardware and CODESYS V3 Various protocols on different interfaces Designed for Industry 4.0 applications Unbeatable price / performance ratio Communicative PLC The DataLine SmartPLC is freely programmable via CODESYS V3 and offers full access to all interfaces of the system. Two Ethernet ports act as EtherCAT fieldbus / slave interface and enable high-performance com- munication to other PLC systems. Different communication protocols can be used in parallel via two further Ethernet ports, e.g. EtherCAT master, EtherNet/IP scanner, Modbus TCP master and slave, TCP/IP, UDP/IP or OPC/UA server. Designed for Industry 4.0 The DataLine SmartPLC is best-equipped for Industry 4.0 applications. Towards the PLC, it acts like a classic AS-i gateway and towards IT, any pro- cess values can be made available via different communication protocols. An integrated real-time clock and an SD card slot complete the features.
  • 66. 67 (11.2016) For further technical details please visit: www.ifm.com Products Order no. SmartSPS DataLine, 1 x AS-i, EtherCAT slave AC1433 SmartSPS DataLine, 2 x AS-i, EtherCAT slave AC1434 Dimensions 106,293 135,5 128,2 Example AC1433 Description DataLine SmartPLC Advantages and customer benefits Communication interfaces: EtherCAT: Certified EtherCAT functionality AS-Interface: 1 and 2 AS-i masters pursuant to M4 profile Configuration interface: 2 Ethernet ports with the following functions: – Web server – CODESYS V3 programming interface – Multifunctional communication interface (EtherCAT master, Modbus TCP, EtherNet/IP scanner, OPC/UA server, Web visualisation) Connections: – AS-i and auxiliary supply: plug-in terminals (supplied with the unit) – EtherCAT 2 x RJ45 – Configuration interface 2x RJ45 Functions The DataLine SmartPLC supports a number of different communication protocols via its both configuration interfaces in order to supply additional input / output data to the integrated PLC or realise a data exchange with other units / systems. For Industry 4.0 applications, there is, amongst others, an OPC server functionality available that enables an easy data transfer into your IT world.
  • 67. 68 AS-Interface cable extensions Repeater to extend AS-i networks up to 1000 m Increased operating temperature range -25...70 °C Reliable long term performance in tough conditions Fast data transfer for Safety at Work Clearly visible diagnostic LEDs Plug-in connection terminals Operation Repeaters are used for AS-Interface to enable the network cable run to be extended beyond 100 m. Galvanic separation of network segments and independent voltage supplies ensure stability. The 62 participants are provided with a higher total current and the voltage drop decreases. Features of the unit The improved performance is packed into the new SmartLine housing. While conventional repeaters usually have a temperature range from 0...55 °C, the new unit from ifm operates reliably across a broad range from -25...70 °C. The improved operating temperature range makes the new unit from ifm a class leader. This results in a longer life time thus saving time and money. Industrial communication