© Copyright 2008, American Fibertek, Inc. 0909JD
Instruction Manual
MX2-MM-FX-ST
MXR2-MM-FX-ST
MX2-SM-FX-ST
MXR2-SM-FX-ST
Media Converter
2
Table of Contents
Functional Description ..............................................................................…3
Installation.................................................................................................... 3
MX2 Power Source...................................................................................... 4
MX2 Power Connection ............................................................................... 4
MX2 Fiber Data Connections....................................................................... 4
MX2 Copper Data Connections ................................................................... 4
MXR2 Power Source ................................................................................... 5
MXR2 Power Connection............................................................................. 5
MXR2 Fiber Data Connections .................................................................... 5
MXR2 Copper Data Connections................................................................. 5
MX2 / MXR2 Status LED Indicators............................................................. 6
Warranty ...................................................................................................... 7
Service Information...................................................................................... 7
3
INSTALLATION AND OPERATION INSTRUCTIONS
INTRODUCTION
Thank you for purchasing your American Fibertek MX2 / MXR2 series media converter. Please take a
few minutes to read these installation instructions in order to obtain the maximum performance from
this product.
FUNCTIONAL DESCRIPTION
The MX2 / MXR2 series combines a single fiber Ethernet port with two copper Ethernet ports. The
MX2-MM-FX-ST, MXR2-MM-FX-ST, MX2-SM-FX-ST, and MXR2-SM-FX-ST units allow transmission
speeds of 10 Mb/s or 100 Mb/s on each of the copper ports. The fiber port transmission speed is set at
100 Mb/s. The MX2 / MXR2 series converts the electronic Ethernet input into an optical output using a
1300 nm wavelength source. The MX2 / MXR2 series also converts an optical Ethernet input signal
returning on a separate fiber into an electronic Ethernet output using a 1300 nm wavelength detector.
The MX2-MM-FX-ST and MXR2-MM-FX-ST units operate on 50 um or 62.5 um multimode fiber with a
maximum distance of 2 Km. The MX2-SM-FX-ST and MXR2-SM-FX-ST units operate on 9 um
singlemode fiber with a maximum distance of 20 Km. Refer to the data sheets for detailed performance
specifications.
The MX2 / MXR2 series is configured to auto negotiate the copper ports to either 10Base-T or
100Base-TX Ethernet data at full or half duplex. The auto negotiate feature also selects the proper MDI
or MDIX interface. The MX2 / MXR2 series fiber port is set to 100Base-FX and is compatible with
IEEE802.3 100Base-FX standard products.
The availability of both a copper and a fiber port allows the MX2 / MXR2 series product to be used as a
straight through Ethernet media converter, changing an electronic data signal to a fiber optic data
signal.
This unit is contained in a compact and rugged aluminum housing with internal dc voltage regulation.
The detachable terminal block, RJ45 Ethernet data connector, and LED indicators provide for easy
installation and monitoring of data and dc power. The MX2 series is designed for mounting as a
modular stand alone unit. The MXR2 series is designed for rack mounting in the MXRC-1 subrack.
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD
CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES.
Mount MX2 series units to a secure surface using #8 (3mm) hardware in four places. See the drawing
on the next page for mounting dimensions. Be sure to allow sufficient room for the required minimum
bend radius of the fiber cable used.
MXR2 series units slide into any open slot in the MXRC-1 subrack. Use a small screwdriver to screw
the top and bottom fasteners into place.
4
DCIN5V
FXLINK
LINK/ACT2LINK/ACT1
SPD
2
SPD
1
RXTX
FIBER
PWR21
Media Converter MX2-MM-FX-SC
10/100BASE-TX To 100BASE-FX
american fibertek
MX2 Series
MX2 SERIES POWER SOURCE
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY.
MX2 series units require a +5VDC power source for proper operation. The DC input is diode protected.
In the USA and in Canada a 5 Volt DC power supply is supplied with this unit. The negative side of the
power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended.
MX2 SERIES POWER CONNECTION
Power is supplied to the MX2 series units via a connection on the right side of the unit (refer to the
drawing above).
MX2 SERIES FIBER DATA CONNECTIONS
The fiber optic connections are made via ST connectors located on the left side of the unit. The TX port
of this unit is connected to the RX port of the corresponding unit.
MX2 SERIES COPPER DATA CONNECTIONS
The UTP Ethernet input/output connections are made via RJ45 plugs on the left side of the unit. A
maximum CAT5 wire length of 100 meters is permitted.
5
DCIN5V
SPD2 PWR
L
I
N
K
/
A
C
T
SPD1 FX LINK
FIBER
RX
TX
2
1
2
1
Media Converter MXR2-MM-FX-SC
10/100BASE-TX To 100BASE-FX
american fibertek
MXR2 Series
MXR2 SERIES POWER SOURCE
Power to MXR2 series units is supplied by the subrack. Please refer to the MXRC-1 and MXRCPS-1
instructions for further details.
MXR2 SERIES POWER CONNECTION
Power is supplied to the MXR2 series units via a four finger backplane connector. The MXR2 series
units can be inserted into the subrack or removed from the subrack with power applied to the
backplane.
MXR2 SERIES FIBER DATA CONNECTIONS
The fiber optic connections are made via ST connectors located on the front of the unit. The TX port of
this unit is connected to the RX port of the corresponding unit.
MXR2 SERIES COPPER DATA CONNECTIONS
The UTP Ethernet input/output connections are made via RJ45 plugs on the front of the unit. A
maximum CAT5 wire length of 100 meters is permitted.
6
MX2 / MXR2 STATUS INDICATORS
The MX2 / MXR2 series units provide the following LED status indicators to aid in troubleshooting:
PWR
A green LED indicator monitors the presence of DC power into the unit. Power status associated with
this LED is summarized below.
PWR Indicator: Power Status:
Green Input Power at Correct Level
Off Check Input Power
FX Link
A Green LED indicator monitors the fiber connection and data flow on the fiber port. Fiber status
associated with this LED is summarized below:
FX Link Indicator: Fiber Port Status:
Solid Green Fiber Connected
Flashing Green Fiber Port Communicating in 100 Mbps Mode
Off Fiber Not Connected
Link/ACT1
A Green LED indicator monitors the copper connection and data flow on copper port #1. Port status
associated with this LED is summarized below:
Link/ACT1 Indicator: Port 1 Status:
Solid Green Port 1 Connected
Flashing Green Port 1 Communicating
Off No Data Flow
SPD1
A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #1. Data status
associated with this LED is summarized below:
SPD1 Indicator: Port 1 Status:
Green Port 1 Connected and in 100 Mbps Mode
Amber Port 1 Connected and in 10 Mbps Mode
Off No Data Flow
Link/ACT2
A Green LED indicator monitors the copper connection and data flow on copper port #2. Port status
associated with this LED is summarized below:
Link/ACT2 Indicator: Port 2 Status:
Solid Green Port 2 Connected
Flashing Green Port 2 Communicating
Off No Data Flow
SPD2
A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #2. Data status
associated with this LED is summarized below:
SPD2 Indicator: Port 2 Status:
Green Port 2 Connected and in 100 Mbps Mode
Amber Port 2 Connected and in 10 Mbps Mode
Off No Data Flow
7
WARRANTY INFORMATION
American Fibertek, Inc warrants that at the time of delivery and for a period of five years thereafter the
products delivered will be free of defects in materials and workmanship. Defective products will be
repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization
(RMA) number is required to send the products back in case of return. All returns must be shipped
prepaid. This warranty is void if the products have been tampered with. This warranty shall be
construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive
jurisdiction over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO
WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR
OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET
FORTH IN THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for
contingent, consequential, or incidental damages. No agreement or understanding, expressed or
implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing,
signed by a duly authorized officer of American Fibertek.
SERVICE INFORMATION
There are no user serviceable parts inside the unit.
In the event that service is required to this unit, please direct all inquiries to:
American Fibertek, Inc. Phone: (877) 234-7200
120 Belmont Drive Phone: (732) 302-0660
Somerset, NJ 08873 FAX (732) 302-0667
E-mail: techinfo@americanfibertek.com

Más contenido relacionado

Destacado

Solidale-Presentation
Solidale-PresentationSolidale-Presentation
Solidale-Presentation
DoParcel
 
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
Todea Nicusor
 

Destacado (8)

American Fibertek MRX8823CSL User Manual
American Fibertek MRX8823CSL User ManualAmerican Fibertek MRX8823CSL User Manual
American Fibertek MRX8823CSL User Manual
 
American Fibertek MT926C User Manual
American Fibertek MT926C User ManualAmerican Fibertek MT926C User Manual
American Fibertek MT926C User Manual
 
Actors
ActorsActors
Actors
 
Solidale-Presentation
Solidale-PresentationSolidale-Presentation
Solidale-Presentation
 
American Fibertek MT-984C-SL User Manual
American Fibertek MT-984C-SL User ManualAmerican Fibertek MT-984C-SL User Manual
American Fibertek MT-984C-SL User Manual
 
Arezzo 16 aprile 2013 Modulo 1 Pianificazione
Arezzo 16 aprile 2013  Modulo 1 PianificazioneArezzo 16 aprile 2013  Modulo 1 Pianificazione
Arezzo 16 aprile 2013 Modulo 1 Pianificazione
 
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
12865041 jeanne-guyon-experimentand-in-profunzime-pe-isus-christos-
 
Материалы с совещания ответственных за организацию воспитательного пространст...
Материалы с совещания ответственных за организацию воспитательного пространст...Материалы с совещания ответственных за организацию воспитательного пространст...
Материалы с совещания ответственных за организацию воспитательного пространст...
 

Más de JMAC Supply

Más de JMAC Supply (20)

Bosch ALTV244UL Data Sheet
Bosch ALTV244UL Data SheetBosch ALTV244UL Data Sheet
Bosch ALTV244UL Data Sheet
 
Bosch AL1002WAL Data Sheet
Bosch AL1002WAL Data SheetBosch AL1002WAL Data Sheet
Bosch AL1002WAL Data Sheet
 
Bosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data SheetBosch AIM-AEC21-CVT Data Sheet
Bosch AIM-AEC21-CVT Data Sheet
 
Bosch AI1 Data Sheet
Bosch AI1 Data SheetBosch AI1 Data Sheet
Bosch AI1 Data Sheet
 
Bosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data SheetBosch AH-24WP-R Data Sheet
Bosch AH-24WP-R Data Sheet
 
Bosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data SheetBosch AEC-8I8O-EXT Data Sheet
Bosch AEC-8I8O-EXT Data Sheet
 
Bosch AE774 Data Sheet
Bosch AE774 Data SheetBosch AE774 Data Sheet
Bosch AE774 Data Sheet
 
Bosch AE203R Data Sheet
Bosch AE203R Data SheetBosch AE203R Data Sheet
Bosch AE203R Data Sheet
 
Bosch AE101 Data Sheet
Bosch AE101 Data SheetBosch AE101 Data Sheet
Bosch AE101 Data Sheet
 
Bosch AE4 Data Sheet
Bosch AE4 Data SheetBosch AE4 Data Sheet
Bosch AE4 Data Sheet
 
Bosch AE1 Data Sheet
Bosch AE1 Data SheetBosch AE1 Data Sheet
Bosch AE1 Data Sheet
 
Bosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data SheetBosch ACD-IC16K37-50 Data Sheet
Bosch ACD-IC16K37-50 Data Sheet
 
Bosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data SheetBosch ACD-IC2K37-50 Data Sheet
Bosch ACD-IC2K37-50 Data Sheet
 
Bosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data SheetBosch ACA-IC2K26-10 Data Sheet
Bosch ACA-IC2K26-10 Data Sheet
 
Bosch 9208B Data Sheet
Bosch 9208B Data SheetBosch 9208B Data Sheet
Bosch 9208B Data Sheet
 
Bosch 7110XC Data Sheet
Bosch 7110XC Data SheetBosch 7110XC Data Sheet
Bosch 7110XC Data Sheet
 
Samsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data SheetSamsung Techwin SNB-1000 Data Sheet
Samsung Techwin SNB-1000 Data Sheet
 
Samsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data SheetSamsung Techwin SMT-4031 Data Sheet
Samsung Techwin SMT-4031 Data Sheet
 
Samsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data SheetSamsung Techwin SMT-4023 Data Sheet
Samsung Techwin SMT-4023 Data Sheet
 
Samsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data SheetSamsung Techwin SMT-3232 Data Sheet
Samsung Techwin SMT-3232 Data Sheet
 

Último

Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
vu2urc
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
giselly40
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
Joaquim Jorge
 

Último (20)

GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf[2024]Digital Global Overview Report 2024 Meltwater.pdf
[2024]Digital Global Overview Report 2024 Meltwater.pdf
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
How to convert PDF to text with Nanonets
How to convert PDF to text with NanonetsHow to convert PDF to text with Nanonets
How to convert PDF to text with Nanonets
 
Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...Driving Behavioral Change for Information Management through Data-Driven Gree...
Driving Behavioral Change for Information Management through Data-Driven Gree...
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Histor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slideHistor y of HAM Radio presentation slide
Histor y of HAM Radio presentation slide
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
Raspberry Pi 5: Challenges and Solutions in Bringing up an OpenGL/Vulkan Driv...
 
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time AutomationFrom Event to Action: Accelerate Your Decision Making with Real-Time Automation
From Event to Action: Accelerate Your Decision Making with Real-Time Automation
 
Tech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdfTech Trends Report 2024 Future Today Institute.pdf
Tech Trends Report 2024 Future Today Institute.pdf
 
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
Apidays Singapore 2024 - Building Digital Trust in a Digital Economy by Veron...
 
Artificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and MythsArtificial Intelligence: Facts and Myths
Artificial Intelligence: Facts and Myths
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemkeProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
ProductAnonymous-April2024-WinProductDiscovery-MelissaKlemke
 
Data Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt RobisonData Cloud, More than a CDP by Matt Robison
Data Cloud, More than a CDP by Matt Robison
 
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
04-2024-HHUG-Sales-and-Marketing-Alignment.pptx
 

American Fibertek MX2-MM-FX-ST User Manual

  • 1. © Copyright 2008, American Fibertek, Inc. 0909JD Instruction Manual MX2-MM-FX-ST MXR2-MM-FX-ST MX2-SM-FX-ST MXR2-SM-FX-ST Media Converter
  • 2. 2 Table of Contents Functional Description ..............................................................................…3 Installation.................................................................................................... 3 MX2 Power Source...................................................................................... 4 MX2 Power Connection ............................................................................... 4 MX2 Fiber Data Connections....................................................................... 4 MX2 Copper Data Connections ................................................................... 4 MXR2 Power Source ................................................................................... 5 MXR2 Power Connection............................................................................. 5 MXR2 Fiber Data Connections .................................................................... 5 MXR2 Copper Data Connections................................................................. 5 MX2 / MXR2 Status LED Indicators............................................................. 6 Warranty ...................................................................................................... 7 Service Information...................................................................................... 7
  • 3. 3 INSTALLATION AND OPERATION INSTRUCTIONS INTRODUCTION Thank you for purchasing your American Fibertek MX2 / MXR2 series media converter. Please take a few minutes to read these installation instructions in order to obtain the maximum performance from this product. FUNCTIONAL DESCRIPTION The MX2 / MXR2 series combines a single fiber Ethernet port with two copper Ethernet ports. The MX2-MM-FX-ST, MXR2-MM-FX-ST, MX2-SM-FX-ST, and MXR2-SM-FX-ST units allow transmission speeds of 10 Mb/s or 100 Mb/s on each of the copper ports. The fiber port transmission speed is set at 100 Mb/s. The MX2 / MXR2 series converts the electronic Ethernet input into an optical output using a 1300 nm wavelength source. The MX2 / MXR2 series also converts an optical Ethernet input signal returning on a separate fiber into an electronic Ethernet output using a 1300 nm wavelength detector. The MX2-MM-FX-ST and MXR2-MM-FX-ST units operate on 50 um or 62.5 um multimode fiber with a maximum distance of 2 Km. The MX2-SM-FX-ST and MXR2-SM-FX-ST units operate on 9 um singlemode fiber with a maximum distance of 20 Km. Refer to the data sheets for detailed performance specifications. The MX2 / MXR2 series is configured to auto negotiate the copper ports to either 10Base-T or 100Base-TX Ethernet data at full or half duplex. The auto negotiate feature also selects the proper MDI or MDIX interface. The MX2 / MXR2 series fiber port is set to 100Base-FX and is compatible with IEEE802.3 100Base-FX standard products. The availability of both a copper and a fiber port allows the MX2 / MXR2 series product to be used as a straight through Ethernet media converter, changing an electronic data signal to a fiber optic data signal. This unit is contained in a compact and rugged aluminum housing with internal dc voltage regulation. The detachable terminal block, RJ45 Ethernet data connector, and LED indicators provide for easy installation and monitoring of data and dc power. The MX2 series is designed for mounting as a modular stand alone unit. The MXR2 series is designed for rack mounting in the MXRC-1 subrack. INSTALLATION THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL CODES. Mount MX2 series units to a secure surface using #8 (3mm) hardware in four places. See the drawing on the next page for mounting dimensions. Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used. MXR2 series units slide into any open slot in the MXRC-1 subrack. Use a small screwdriver to screw the top and bottom fasteners into place.
  • 4. 4 DCIN5V FXLINK LINK/ACT2LINK/ACT1 SPD 2 SPD 1 RXTX FIBER PWR21 Media Converter MX2-MM-FX-SC 10/100BASE-TX To 100BASE-FX american fibertek MX2 Series MX2 SERIES POWER SOURCE THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY ONLY. MX2 series units require a +5VDC power source for proper operation. The DC input is diode protected. In the USA and in Canada a 5 Volt DC power supply is supplied with this unit. The negative side of the power input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended. MX2 SERIES POWER CONNECTION Power is supplied to the MX2 series units via a connection on the right side of the unit (refer to the drawing above). MX2 SERIES FIBER DATA CONNECTIONS The fiber optic connections are made via ST connectors located on the left side of the unit. The TX port of this unit is connected to the RX port of the corresponding unit. MX2 SERIES COPPER DATA CONNECTIONS The UTP Ethernet input/output connections are made via RJ45 plugs on the left side of the unit. A maximum CAT5 wire length of 100 meters is permitted.
  • 5. 5 DCIN5V SPD2 PWR L I N K / A C T SPD1 FX LINK FIBER RX TX 2 1 2 1 Media Converter MXR2-MM-FX-SC 10/100BASE-TX To 100BASE-FX american fibertek MXR2 Series MXR2 SERIES POWER SOURCE Power to MXR2 series units is supplied by the subrack. Please refer to the MXRC-1 and MXRCPS-1 instructions for further details. MXR2 SERIES POWER CONNECTION Power is supplied to the MXR2 series units via a four finger backplane connector. The MXR2 series units can be inserted into the subrack or removed from the subrack with power applied to the backplane. MXR2 SERIES FIBER DATA CONNECTIONS The fiber optic connections are made via ST connectors located on the front of the unit. The TX port of this unit is connected to the RX port of the corresponding unit. MXR2 SERIES COPPER DATA CONNECTIONS The UTP Ethernet input/output connections are made via RJ45 plugs on the front of the unit. A maximum CAT5 wire length of 100 meters is permitted.
  • 6. 6 MX2 / MXR2 STATUS INDICATORS The MX2 / MXR2 series units provide the following LED status indicators to aid in troubleshooting: PWR A green LED indicator monitors the presence of DC power into the unit. Power status associated with this LED is summarized below. PWR Indicator: Power Status: Green Input Power at Correct Level Off Check Input Power FX Link A Green LED indicator monitors the fiber connection and data flow on the fiber port. Fiber status associated with this LED is summarized below: FX Link Indicator: Fiber Port Status: Solid Green Fiber Connected Flashing Green Fiber Port Communicating in 100 Mbps Mode Off Fiber Not Connected Link/ACT1 A Green LED indicator monitors the copper connection and data flow on copper port #1. Port status associated with this LED is summarized below: Link/ACT1 Indicator: Port 1 Status: Solid Green Port 1 Connected Flashing Green Port 1 Communicating Off No Data Flow SPD1 A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #1. Data status associated with this LED is summarized below: SPD1 Indicator: Port 1 Status: Green Port 1 Connected and in 100 Mbps Mode Amber Port 1 Connected and in 10 Mbps Mode Off No Data Flow Link/ACT2 A Green LED indicator monitors the copper connection and data flow on copper port #2. Port status associated with this LED is summarized below: Link/ACT2 Indicator: Port 2 Status: Solid Green Port 2 Connected Flashing Green Port 2 Communicating Off No Data Flow SPD2 A bi-colored LED indicator monitors the speed of the data flow on RJ45 copper port #2. Data status associated with this LED is summarized below: SPD2 Indicator: Port 2 Status: Green Port 2 Connected and in 100 Mbps Mode Amber Port 2 Connected and in 10 Mbps Mode Off No Data Flow
  • 7. 7 WARRANTY INFORMATION American Fibertek, Inc warrants that at the time of delivery and for a period of five years thereafter the products delivered will be free of defects in materials and workmanship. Defective products will be repaired or replaced at the exclusive option of American Fibertek. A Return Material Authorization (RMA) number is required to send the products back in case of return. All returns must be shipped prepaid. This warranty is void if the products have been tampered with. This warranty shall be construed in accordance with New Jersey law and the courts of New Jersey shall have exclusive jurisdiction over this contract. EXCEPT FOR THE FOREGOING WARRANTY, THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, EXPRESSED OR IMPLIED, WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT. In any event, American Fibertek will not be responsible or liable for contingent, consequential, or incidental damages. No agreement or understanding, expressed or implied, except as set forth in this warranty, will be binding upon American Fibertek unless in writing, signed by a duly authorized officer of American Fibertek. SERVICE INFORMATION There are no user serviceable parts inside the unit. In the event that service is required to this unit, please direct all inquiries to: American Fibertek, Inc. Phone: (877) 234-7200 120 Belmont Drive Phone: (732) 302-0660 Somerset, NJ 08873 FAX (732) 302-0667 E-mail: techinfo@americanfibertek.com