2. Table of Contents:
11 Small IT Challenges that InfraStruxure Solves
Integrated InfraStruxure™
solutions include everything for your IT physical
infrastructure deployment: backup power and power distribution,
cooling, enclosures, and management software. Adaptable solutions
scale from the smallest IT spaces up to multi-megawatt data centers.
Findanauthorizedresellerof
APC™
bySchneiderElectric™
inyourarea.
The products in this guide are available for sale through
our authorized resellers. To find a reseller in your area,
please visit our Reseller Locator Page.
www.apc.com/tools/locator/
Protection strategies for recently
virtualized server rooms and closets1
Optimizing space in a newly
consolidated server room2
Consolidating server and network
equipment in legacy computer rooms3
Deploying equipment in telecom,
data rooms, and closets4
Optimized management and safe
shutdown for virtualized server rooms5
Deploying equipment off site in
co-location sites or the cloud6
Deploying IT equipment outside
of the dedicated IT space7
Deploying networking equipment
outside of the dedicated IT space8
Minimizing the use of floor space
with wall-mounted IT racks9
Installing IT equipment into tight spaces10
Cost-effective solutions for small business
server rooms and network closets11
4. Virtualized
serverrooms
Enterprise
branchoffices
Recently
consolidated
equipment
Cloud
connection
andon-site
storage
Target
Segmentsand
Applications
InRow™
SC cooling units provide 5.25 kW cooling capacity. This
self-contained system does require ducting hot air into a plenum
space above the room. If cooling is already present in the room,
this is a great way to provide supplemental AC without changing
the building HVAC system. These cooling units install in row with
our IT racks, which consumes minimal floor space.
A NetBotz™
rack manager with door sensor
will provide simple security information remotely,
allowing you to respond to environmental and
physical threats when they occur.
This all-in-one solution allows for one-rack management, via our
simple management interface. It provides output voltage at both
208 V and 120 V to accommodate mixed IT equipment, and
is designed to provide customized runtime depending on the
application. Our PowerChute™
software allows for virtual machine
shutdown in the event of power outage to avoid the risk of hard
shutdowns, corruption, or data loss.
Packing all of your IT equipment into one rack can
impact the cooling requirements necessary for
servers. Experts at APC can help you determine
a cooling strategy for your server room that uses
building AC as well as supplemental cooling.
The runtime of this solution is customizable by
adding additional 3U battery packs. Each pack
adds approximately 15 minutes at full load.
Remote management of this solution requires
the use of two network ports and IP address.
This solution allows control of UPS, monitoring
of rack temperature, and door status (open or
closed). Proactive notifications and warnings
for unauthorized access, UPS power issues,
outages, and even battery life are sent via email.
Explore the user interface and options a
testdrive.apc.com
AdditionalDetailsandOptions
« Rear view of UPS
Bill of Materials
Smart-UPS™
Online 8 kVA with Step Down Transformer SURT8KRMXL6U-TF5
NetShelter™
SX Enclosure AR3100
InRow SC Self-contained Cooling Unit ACSC100
NetBotz Rack Monitor with Temperature Sensor NBRK0201
NetBotz Rack Door Sensor NBES0303
Vertical Cable Management AR8442
Solution Attributes
Rack Equipment Capacity 33U
Power Capacity 8 kVA (6.4 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and accounts
for outlets used by powered solution components)
(HW) 2PH + G
(1) L6-30R
(2) L6-20R
(11) 5-20R
Connection Type for UPS Hardwire (2PH + G)
Runtime as Configured at Full Load 7.3 minutes
Cooling Capacity 5.25 kW
3
«P/N: SURT192SR2XLBF
FindanAPCby
SchneiderElectric
authorizedreseller
5. “NowthatIhaveconsolidatedmyITequipment,Ino
longerneedallofthespacethatmylegacyserver
roomoccupied.Isthereawayformetoconsolidate
intoamoremanageableinstallation?”
ConsolidatedEnvironmentSolutions/ServerRooms
Optimizingspaceinanewly
consolidatedserverroom
Challenge
Deployaneasilyscalableserver
roomarchitecture.
So you consolidated your equipment from 10 racks to
three, and want to limit your expenses on power and
cooling, while at the same time maintaining availability?
This solution is designed to be repeated either at the same
site or different sites, providing shelter and uninterruptible
power for your equipment.
This solution is designed to replace legacy IT infrastructure
in a space that already contains some cooling capability.
Providing ventilation in the rack also allows you to make
the best use of existing HVAC and room cooling solutions,
making this architecture perfect for rollouts in existing
IT spaces.
We have kept it simple and provided the basic functionality
to ensure that you can remotely manage and control the
physical infrastructure.
Solution
Remotely
manageable
poweroutlets
Onerackto
managewith
integrated
powerand
cooling
Canbe
orderedwith
pre-installed
components
Scalable
runtime
solutionfor
customized
powerbackup
time
Proactive
notifications
keeptheright
peopleupto
date
Repeatable
solution
Benefits
4
NorthAmerica
6. Serverrooms
Enterprise
branchoffices
TemporaryIT
installations
Recently
consolidated
equipment
Cloud
testingand
deployment
Serverrooms
requiringfast
growthusing
repeatable
all-in-one
solutions
Target
Segmentsand
Applications
A simple, repeatable architecture for installations in 3 kVA increments.
As suggested, providing 30 minutes of runtime while leaving 37U for
equipment optimizes the rack space. This solution is designed to
provide rack-level UPS power protection and enough outlets to
accommodate a mix of servers and networking equipment.
The NetBotz rack monitor device
can be installed in the rear of the
rack and has a range of additional
probes and sensors to proactively
alert users of issues.
This solution has been designed for use in
rooms which are already sufficiently cooled by a
building or room AC system. If additional cooling
is needed, a portable cooling system is available
and can be easily added to this solution. The
unit, an ACPSC3500, is shown above with the
required ducting kit in place.
Installing and managing
cables within an IT rack
can be challenging.
APC offers many different
style cable management
accessories that can tame
existing cables, or help
route new ones.
Check out the selection on www.apc.com,
if you are looking for something other than
basic vertical and horizontal brackets.
Remote management of this solution requires
the use of two network ports and IP addresses.
This solution allows control of individual outlets,
monitoring of temperature, humidity, and rack
or room door status (open/closed), as well
as proactive notifications and warnings for
power issues, outages, and even battery life.
Explore the user interface and options at
testdrive.apc.com
AdditionalDetailsandOptions
Bill of Materials
Smart-UPS X 3 kVA UPS with Network Card SMX3000RMLV2UNC
Smart-UPS Extended Run Battery Pack SMX120RMBP2U
NetShelter SX Enclosure AR3100
Rack Roof Ventilation Fan ACF501
Switched Rack Power Distribution Unit AP7932
NetBotz Rack Monitor NBRK0201
NetBotz Rack Door Sensor NBES0303
Vertical Cable Manager AR8442
Solution Attributes
Rack Equipment Capacity 37U
Power Capacity 3 kVA (2.7 kW)
Power Output Voltage 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(26) 5-20R
(3) 5-15R
Connection Type for UPS L5-30P
Runtime as Configured at Full Load 32.7 minutes (incl. 1 battery pack)
5
«ACPSC3500 self-contained
portable cooling system
« NetBotz rack monitor
FindanAPCby
SchneiderElectric
authorizedreseller
8. Serverrooms
Enterprise
branchoffices
Retailstores
Recently
consolidated
equipment
Virtualized
servers
Target
Segmentsand
Applications
A Symmetra™
LX UPS system can provide
N+1 redundant power protection and offer
the scalability you need for future growth. The
system grows in power increments of 4 kVA
and is a modular design, making servicing the
unit easy for a non-technical person.
A centralized UPS can provide
power to multiple racks, and in
this solution we provide power
to all three racks using one UPS.
If you only need one camera, consider a lower
cost alternative to the recommendation above.
The NBWL0356, is a camera pod with
environmental monitoring capabilities. It is
not scalable like the 550, but can offer basic
functions at the right price.
The Symmetra LX UPS system is configurable
for N+1 redundancy, adding availability and peace
of mind with a simple upgrade. Server rooms
often are equipped with basic in room air
conditioning systems. If you need supplemental
cooling, our InRow SC self-contained cooling
system can be installed to provide additional
cooling. Shown above, our InRow cooling
system installs between racks and provides up
to 5.25 kW of cooling capacity. P/N: ACSC100.
As configured, adding (1) SYPM4KP will give
additional power redundancy in the event of any
issues. Remote management of this solution
requires the use of one network port and IP
address. This solution allows control of outlets,
monitoring of internal and external temperature
and proactive notifications and warnings for
power issues, outages, and even battery life.
Explore the user interface and options at
testdrive.apc.com
AdditionalDetailsandOptions
«NetBotz Camera
provides remote
video surveillance
over the network
« NBWL0356 «SYPM4KP
Bill of Materials
NetShelter SX Server Rack (23.6 in. width) (2) AR3100
NetShelter SX Networking Rack (29.5 in. width) (1) AR3140
Symmetra LX Rack mount UPS System (1) SYA16K16RMP
Rack Roof Ventilation Fans (2) ACF501, (1) ACF503
Switched Rack Power Distribution Unit (3) AP7930
Cable Management Accessory (3) AR8442
NetBotz Monitoring and Surveillance (1) NBRK0551
NetBotz Camera Pod (1) NBPD0160
Optional Battery Pack SYARMXR9B9 (+26 minutes)
Solution Attributes
Rack Equipment Capacity 106U (3 racks)
Power Capacity 16 kVA (12.8 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(HW) 2PH + N + G
(4) L14-30R
(5) L5-20R
(71) 5-20R
Connection Type for UPS (HW) 2PH + N + G
Runtime as Configured at Full Load 6 minutes
7
FindanAPCby
SchneiderElectric
authorizedreseller
10. Networkclosets
Telecomrooms
Communication
closets
VoIPsystems
Consolidated
equipment
Cloudconnection
Target
Segmentsand
Applications
AdditionalDetailsandOptions
Bill of Materials
NetShelter SX 45U Rack (600 mm wide) AR3105
NetShelter SX 45U Networking Rack (750 mm wide) AR3155
Smart-UPS 5 kVA with 208 V and 120 V output (3U) SURTD5000RMXLP3U
Switched Rack Power Distribution Unit (2) AP7931
Horizontal Cable Manager (2U) AR8606
Vertical Cable Manager AR8606
Solution Attributes
Rack Equipment Capacity 85U (2 racks)
Power Capacity 5 kVA (4 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L14-30R
(1) L6-30R
(3) 5-20R
(16) 5-15R
Connection Type for UPS L14-30P
Runtime as Configured at Full Load 5 minutes
9
In networking applications,
cable management is
critical. We have included
networking cable managers
in the standard networking
rack, which provide a cable
finger at each U space.
This allows for clean and
organized cable routing
around switches and through
to the rear of the rack.
«P/N:AR7751
For a low cost heat removal option, the VED,
vertical exhaust duct, can be installed on
standard and wide racks, providing contained
heat removal into a plenum space return.
»This solution includes the
AP7931, which has 16
standard 5-15R outlets.
NetShelter racks are some of the easiest to work with in
the industry. They arrive pre-assembled, have removable
sides, and adjustable rails. Removing the doors and side
panels allows for fast cabling, reducing the install time of
networking gear. When you are finished, the racks are
completely secure with lockable side panels and doors.
The 5 kVA Split-phase UPS system provides both 208 V
and 120 V in the rack. This design provides five minutes of
runtime. By adding more battery packs, the runtime can
be customized. Adding (1) SURT192RMXLBP3U
will increase the runtime to 25 minutes.
A rack PDU is an easy way to distribute UPS power within
a rack or to an adjacent rack.
»Interior view of NetShelter SX to
show cable management and airflow
FindanAPCby
SchneiderElectric
authorizedreseller
12. Smallbusiness
computer
room
Virtualized
servers
Target
Segmentsand
Applications
Rack roof fans can provide a surprising amount of heat extraction
and eliminate hotspots by keeping air moving through the rack.
A self-contained portable cooling system from APC can be
positioned to provide additional cooling right where you need it.
This does require the venting duct shown in the image below.
This unit can provide 3.5 kW of cooling capacity.
Remote management of this solution requires
the use of one network port and IP address. This
solution allows control of the UPS, monitoring of
rack temperature, as well as proactive notifications
and warnings for power issues, outages, and
even battery life. Event logs and data logs store
important information which can be downloaded
or analyzed to help make decisions about
future IT deployment. In addition to remote
management, the included network management
card supports the graceful, unattended shutdown
of many different types of server operating
systems, including some virtual machines.
PowerChute Network Shutdown software, a free
download from APC, can be installed and can
even be programmed to initiate a graceful server
shutdown in the event of a power outage,
scheduled event, or even shutdown or reboot a
server on demand. This is an extremely useful
tool to protect servers, applications, and data
from corruption. Explore the user interface and
options at testdrive.apc.com
AdditionalDetailsandOptions
« xxxxxxx
Bill of Materials
NetShelter SX Enclosure AR3100
Smart-UPS Online UPS SURTD5000RMXLT3U
Smart-UPS Battery Pack SURT192RMXLBP3U
208 V to 120 V Step-down Transformer AP9626
Rack Roof Ventilation Fan ACF501
Portable Self-contained Cooling Unit ACPSC3500
Vertical Cable Manager AR8442
Solution Attributes
Rack Equipment Capacity 34U
Power Capacity 5 kVA (3.5 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and accounts
for outlets used by powered solution components)
(1) L6-30R
(2) L6-20R
(12) 5-20R
Connection Type for UPS L6-30P
Runtime as Configured at Full Load 31.5 minutes (incl. 1 battery pack)
«ACPSC3500 self-
contained portable
cooling system
11
«Rack roof fan
«Rear view of UPS
FindanAPCby
SchneiderElectric
authorizedreseller
14. Virtualized
serverrooms
Recently
consolidated
equipment
Cloud
connection
andon-site
storage
Co-located
equipment
On-premise
critical
business
applications
Target
Segmentsand
Applications
The new Smart-UPS X 3000 is a high-performance,
high-efficiency UPS system, capable of providing over 30
minutes of runtime with one additional battery pack, shown
at left. UPS systems provide runtime when utility power
fails, keeping critical computing and connection equipment
operational. This UPS is also equipped with a network
management card, which allows remote monitoring of
power conditions, as well as control of three separate
banks of outlets, letting you shed loads and reboot devices.
Remote management of this solution requires
the use of two network ports and IP addresses.
This solution allows control of individual outlets,
monitoring of temperature, humidity, and rack
or room door status (open/closed), as well as
proactive notifications and warnings for power
issues, outages, and even battery life.
Explore the user interface and options at
testdrive.apc.com
AdditionalDetailsandOptions
Bill of Materials
24U NetShelter SX Enclosure AR3104
3 kVA Smart-UPS X 120 V with NMC Card SMX3000RMLV2UNC
Battery Pack (30 mins runtime each) SMX120RMBP2U
Roof Fan Tray ACF501
Service Bypass PDU SBP3000RM
Vertical Cable Manager AR8442
Solution Attributes
Rack Equipment Capacity 20U
Power Capacity 3 kVA (2.7 kW)
Power Output Voltage 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L5-30R
(7) 5-20R
(2) 5-15R
Connection Type for Solution L5-30P
Runtime as Configured at Full Load 31 minutes (incl. 1 battery pack)
13
If 24U is not enough, consider
another size. Our NetShelter SX
enclosures are available in several
other sizes to accommodate
more equipment.
• AR3104 – 24U
600 mm W
x 1,070 mm D
• AR3100 – 42U
600 mm W
x 1,070 mm D
• AR3105 – 45U 600 mm W x 1,070 mm D
• AR3107 – 48U 600 mm W x 1,070 mm D
«SMX3000RMLV2UNC with external battery pack
Protecting critical loads means removing points of
failure and having a plan in place for any circumstance
that threatens business continuity. This solution
includes using a Service Bypass PDU to ensure that
critical loads can be powered at all times. This allows
you to change UPS configurations and even move equipment without the need of powering it down.
This device is small enough to mount in the rear of the rack, or along the rear rails, consuming no
U spaces. Together with a UPS, this gives uninterrupted power for the longevity of the connected
equipment, providing maximum availability for your most critical loads.
FindanAPCby
SchneiderElectric
authorizedreseller
16. Bankbranches
Enterprise
branchoffices
Retailstores
Schools
Conference
rooms/VDC
Homeoffice
Audio/Visual
Medicaloffices
Government
Leasedand
temporaryspace
Target
Segmentsand
Applications
15
Bill of Materials
24U NetShelter CX Enclosure AR4024
3 kVA Smart-UPS X 120 V with NMC Card SMX3000RMLV2UNC
Battery Pack (30 mins runtime each) SMX120RMBP2U
Temperature Probe for inlet air AP9335T
Cable Management Accessory AR8442
Solution Attributes
Rack Equipment Capacity 20U
Power Capacity 3 kVA (2.4 kW*)
Power Output Voltage 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L5-30R
(3) 5-20R
(14) 5-15R
Connection Type for UPS L5-30P
Runtime as Configured at Full Load 31 minutes (incl. 1 battery pack)
«Suggested application
»Pre-installed
Basic Power
Distribution
Unit mounted in
rear of cabinet
(included with
cabinet purchase)
AdditionalDetailsandOptions
«NetShelter CX Enclosures 38U – 12U
« AP9335TH (temp/humidity)
«SMX120RMBP2U
NetShelter CX Enclosures are available in three sizes ranging from 18U
to 38U, as well as a 12U “MINI” version for tower server applications.
This solution can be configured for longer runtime on battery by adding
additional 2U battery packs. Combination temperature and humidity
sensors are available. This solution ships with temperature sensors only.
Remote management of this solution requires the use of one network port
and IP address. This solution allows control of the UPS, monitoring of
temperature and humidity, as well as proactive notifications and warnings
for power issues, outages, and even battery life. Explore the user interface
and options at testdrive.apc.com
«AP9335T
(temperature)
«Rear view of UPS
«Vertical cable
managers keep
cables neat and
organized
«Temperature
probes in front
and rear for
monitoring
« Rear-mounted fan modules
keep equipment at optimum
temperatures
FindanAPCby
SchneiderElectric
authorizedreseller
18. Bankbranches
Enterprise
branchoffices
Retailstores
Schools
Conference
rooms/VDC
Homeoffice
Audio/Visual
Medicaloffices
Government
Leasedand
temporary
space
Target
Segmentsand
Applications
17
Bill of Materials
38U NetShelter CX Enclosure AR4038
3 kVA Smart-UPS X 120 V with NMC Card SURTD5000RMXLP3U
Smart-UPS Battery Pack SURT192RMXLBP3U
Temperature Probe for inlet air AP9335T
Cable Management Accessory AR8442
Switched Rack Power Distribution Unit AP7931
Solution Attributes
Rack Equipment Capacity 32U
Power Capacity 5 kVA (3.6 kW*)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L14-30R
(1) L6-30R
(3) 5-20R
(11) 5-15R
Connection Type for UPS L14-30P
Runtime as Configured at Full Load 27 minutes (incl. 1 battery pack)
«Suggested application
»Pre-installed
Basic Power
Distribution
Unit mounted in
rear of cabinet
(included with
cabinet purchase)
«Vertical cable
managers keep
cables neat and
organized
«Temperature
probes in front
and rear for
monitoring
« Rear-mounted fan modules
keep equipment at optimum
temperatures
AdditionalDetailsandOptions
«NetShelter CX Enclosures 38U - 12U
NetShelter CX Enclosures are available in three sizes ranging from 18U
to 38U, as well as a 12U “MINI” version for tower server applications.
This solution can be configured for longer runtime on battery by adding
additional 2U battery packs. Combination temperature and humidity
sensors are available. This solution ships with temperature sensors only.
Remote management of this solution requires the use of one network port
and IP address. This solution allows control of the UPS, monitoring of
temperature and humidity, as well as proactive notifications and warnings
for power issues, outages, and even battery life. Explore the user interface
and options at testdrive.apc.com
« AP9335TH (temp/humidity)«AP9335T
(temperature)
«P/N: SURT192RMXLBP3U
»Additional switched
PDU provides
controllable,
metered outlets
*Output power capacity has been de-rated based on the ventilation capacity of the 24U NetShelter CX
«Rear view of UPS
FindanAPCby
SchneiderElectric
authorizedreseller
20. POS
applications
Retailstore
networking
Schools
Tightspaces
Industrialshop
floor
Warehouse
floor
Smallbusiness
networking
Cloud/ISP
connection
Target
Segmentsand
Applications
This enclosure is designed to easily accommodate
all types of equipment and arrives with reversible
mounting rails, allowing for either threaded hole or
square hole mounting.
The WX enclosure also pivots off the wall
to provide access to the rear for equipment
maintenance and installation
AdditionalDetailsandOptions
«Three different cable egress
paths help for routing power
and data cables separately.Top,
Side, and Bottom knockouts are
available and can be fitted with
conduit fittings or grommets.
Bill of Materials
NetShelter WX Wall-mount enclosure AR100
NetShelter WX Roof Fan System AR8206ABLK
Smart-UPS 750 VA Rackmounted UPS SMT750RM2U
UPS Network Management Card AP9631
Solution Attributes
Rack Equipment Capacity 11U
Power Capacity 750 VA (500 W)
Power Output Voltage 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and accounts
for outlets used by powered solution components)
(6) 5-15R
Connection Type for UPS 5-15P
Runtime as Configured at Full Load 5.5 minutes
«Labeled U Spaces help for
planning and installations
during equipment rollouts
19
«A roof fan tray extracts
hot air and allows the
circulation of cooler air
into the enclosure
The UPS system in this design has a group
of controllable outlets which can be rebooted
remotely. This can help by allowing remote
troubleshooting of hung equipment.
FindanAPCby
SchneiderElectric
authorizedreseller
22. Network
closets
Enterprise
branchoffices
Retailstores
Telecom
rooms
Phone
systems
Target
Segmentsand
Applications
When it comes to standard networking and telecom applications, our
solutions address the main issues with using spaces that are often
tight and out of the way. Managing cables becomes critical to reducing
troubleshooting time and keeping the space neat and clean. Our cable
managers can bolt onto existing racks or be integrated into an APC
two-post rack.
Flexible solutions that allow for quick scalability are important, but so are
costs. We have designed a simple solution that is both cost effective, and
adaptable for a room of any size.
Center-mounting UPS units and other heavy equipment can help
distribute the weight in a two-post rack environment. The AP9625 rail
kit can be used to center mount equipment in the rack. This solution
can be configured for longer runtime on battery by adding additional 3U
battery packs: SURT192RMXLBP3U.
Camera Pods are a great way to increase security in a critical
networking space. The NetBotz rack monitor 550 will support up
to four USB camera pods: NBPD0160. NetBotz rack monitor 550
management solution requires the use of one network port and IP
address. This solution allows monitoring of room temperature, and is
expandable to four cameras and up to 78 universal sensors. These
sensors monitor doors, leaks, and smoke detectors. Explore the user
interface and sensor/camera options at testdrive.apc.com
AdditionalDetailsandOptions
Bill of Materials
Smart-UPS Online 5 kVA SURTD5000RMXLT3U
208 V to 120 V Step-down Transformer AP9627
NetShelter Two-post Rack AR201
Vertical Cable Management Tower AR8615
Switched Rack Power Distribution Unit AP7930
Horizontal Cable Manager AR8606
NetBotz Monitoring and Surveillance NBRK0551
Portable Cooling Unit ACPSC3500
Solution Attributes
Rack Equipment Capacity 37U
Power Capacity 5 kVA (3.5 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L6-30R
(2) L6-20R
(3) L5-20R
(23) 5-20R
Connection Type for UPS L6-30P
Runtime as Configured at Full Load 6.3 minutes
21
«Suggested application of the solution
components shown here with network
cabling and devices installed
«AP9625 rail kit
«NBPD0160
NetBotz scalable rack and room monitor
solutions allow you to keep an eye on all of your
critical spaces, no matter their size or shape.
Vertical cable managers maintain organized
cables at each u space and simplify cable routing
and installation. Six inch depth cable fingers can
accommodate 50+ cat6 cables
« P/N: SURT192SR2XLBF
FindanAPCby
SchneiderElectric
authorizedreseller
24. Serverrooms
Enterprise
branchoffices
Network
closets
Recently
consolidated
equipment
Low-cost
solutions
Target
Segmentsand
Applications
A four-post open frame rack can be a simple way to keep equipment
organized and off the floor. Our solution includes additional cable managers
which attach to the sides and in between racks to form an organized row to
accommodate both servers and networking equipment.
Vertical cable managers maintain organized cables at each U space and
simplify cable routing and installation. Six inch depth cable fingers can
accommodate 50+ cat6 cables.
A portable cooling unit is an easy way to keep equipment cool without any
change to your buildings HVAC or ventilation system. Our system vents hot
air into a drop ceiling and can even evaporate the condensed water.
For networking applications, a threaded hole rack
can make installation of devices faster. Consider
the AR204A for threaded hole applications or
preference. The solution above includes our
square-hole rack since we expect it to be used
for mixed IT equipment.
Video surveillance of server room spaces can
help piece together the facts when things go
wrong, as well as provide eyes and ears in a
remote room. This solution can be upgraded to
include our any of our NetBotz surveillance and
monitoring components:
Rack Monitor (Environment Only) NBRK0201
Rack Monitor ( Video Surveillance) NBRK0551
Camera Pod (Requires NBRK0551) NBPD0160
Door Sensor (Add to any appliance) NBES0303
More NetBotz sensors and options are available,
please visit at www.apc.com for more info.
Remote management of this solution requires
the use of one network port and IP address. This
solution allows control of the UPS, monitoring of
temperature and humidity, as well as proactive
notifications and warnings for power issues,
outages, and even battery life. Explore the user
interface and options at testdrive.apc.com
AdditionalDetailsandOptions
Bill of Materials
NetShelter Four-post Open Frame Rack (2) AR203A
Smart-UPS Online 5 kVA SURTD5000RMXLT3U
208 V to 120 V Step-down Transformer AP9627
Smart-UPS Extended Run Battery Pack SURT192RMXLBP3U
Switched Rack Power Distribution Unit AP7930
rPDU Mounting Bracket AR8652
Vertical Cable Management Tower AR8625
Horizontal Cable Manager AR8606
Portable Self-contained Cooling Unit ACPSC3500
Solution Attributes
Rack Equipment Capacity 78U (2 racks)
Power Capacity 5 kVA (3.5 kW)
Power Output Voltage 208 V and 120 V
Total Available Power Outlet Types
(this attribute includes all outlets in the solution, and
accounts for outlets used by powered solution components)
(1) L6-30R
(2) L6-20R
(3) L5-20R (24) 5-20R
Connection Type for UPS L6-30R
Runtime as Configured at Full Load 31.5 minutes (incl. 1 battery pack)
23
« Vertical cable manager
«ACPSC3500 self-contained
portable cooling system
FindanAPCby
SchneiderElectric
authorizedreseller