HUAWEI TECHNOLOGIES CO., LTD.
Huawei UPS5000-E Series 40-480kVA
Modular Uninterruptible Power System
Corporate Information
Globalization, localization
Market & Management
■ Leading global ICT solution provider
■ Major contributor of telecom standard, first share of many products
and solutions
■ Create value for customers continuously for 20 years, grow steadily
for 20 years
■ Sales revenue reached CNY 220.2 billion in 2012
■ There BGs (carrier BG, enterprise BG, consumer BG) were founded
in 2011, the enterprise BG and consumer BG grow fast and become
two new and stable economic growth points of the group
Sales revenue (CNY 0.1 billion)
2007 2008 2009 2010 2011 2012
2202
2039
1825
1466
1231
922
Shenzhen Headquarters
Account sharing center
Bidding center
Logistic center, transfer station
R&D center
Training center
Technical support center
Huawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and strong partnerships, we
have established end-to-end capabilities and strengths across the carrier networks, enterprise, consumer, and cloud computing fields.
Huawei is among the world top 500 enterprises, our products and solutions have been deployed in over 140 countries, serving more
than one third of the world's population. There are total 155,000 employees working here.
About Huawei Network Energy
Mexico
Netherland Germany
Brazil
Argentina
Hungary
Romania
India
China
Bahrain
MalaysiaUnited Arab
Emirates
Mauritius
•• 20 global R&D centers
•• 45 global training centers
•• 130+ service branches
•• 13 global customized centers
•• 27,000+ stuffs for service
•• 3,500 certification partners
•• 50,000 certification engineers
from partners
San Diego
USA
Dallas
USA
Moscow
Russia
Bangalore
India
Stockholm/Goteborg
Sweden
Munich
Germany
■ Huawei 5000-E "Data Center Product
Excellence Award"
■ CommunicAsia "Green science and
Technology Award"
■ DCD Data Center "The blueprint Award"
■ "Energy star" certification
■ Deutsche Telekom "The best site design
award"
■ "Desktop cloud container data center"
Uptime Institute TIER3 certification
Supply chain
center
R&D center
Shenzhen supply center
India supply center Shenzhen Chengdu Nanjing
Xi'an
Stockholm
Sweden
Nuremburg
Germany
Beijing Wuhan Shanghai
Network energy productline is one of four main productlines in Carrier BG. We are committed to help our customer build strong
infrastructures for network and protect the long-term investment in energy infrastructure through providing efficient, reliable and
intelligent network energy. Huawei network energy productline takes full advantage of the Global intellectual resources and 9 R&D
centers have been set up at Germany (Nuremberg), Sweden (Stockholm) and China. As far as the end of 2012, network energy
productline had filed 550+ patent applications and the sales revenue had reached 1 billon US dollars.
Huawei Network Energy
Network Energy Product
NetEco
Intelligent
management
system
Embedded power (30~400A) Outdoor power (30~600A) Indoor power (100~24000A)
Site power
Diesel hybrid Solar hybrid Grid hybrid
Hybrid power
Modular and container DC UPS (1~800kVA)
Row/room level precision air
conditioner (20~150kw)
Data center UPS
& air conditioner
Hungary supply center
Mexico supply center
Brazil supply center
Distribution center
in Netherland and Dubai
UPS5000-E Overview............................................. 1
Ultra-high Availability ............................................ 2
High Operating Efficiency ...................................... 3
Excellent Usability.................................................. 4
Comprehensive Reliability Assurance ..................... 5
Intelligent Management System ............................ 6
UPS5000-E Composition........................................ 7
Technical Data..................................................... 10
Contents
UPS5000-E Overview
Rated Capacity: 40-480kVA (1-12 power modules)
Rated Voltage: 380/400/415 Vac
Rated Frequency: 50/60 Hz
Type: Online, double-conversion, modular
Application scenarios:
■ Financial datacenter
■ Internet datacenter
■ Disaster recovery datacenter
■ Telecom central offices
1Huawei UPS5000-E Series Modular Uninterruptible Power System
Ultra-high Availability
Smooth capacity expansion
■ To avoid power interruption risk in capacity expansion, the
capacity of UPS system is planned large enough to meet the
power demand in 3-5 years, which leads to low efficiency
operation at the initial stage due to low load rate
■ UPS5000-E uses module design and all of power module,
bypass module, and control module support hot-swap, which
makes smooth capacity expansion according to demand
possible and reduces the initial investment
>> All hot-swap module design
Online maintenance, reducing MTTR greatly
■ Availability is used to weight the degree that a system,
subsystem or equipment is in operable and committable state.
It's positively related to MTBF (Mean Time Between Failures)
and negatively related to MTTR (Mean Time To Repair)
■ For traditional UPS, customers need seek help from the
suppliers and long recovery time is required because in
maintenance engineers need shutdown and dismantle the
UPS, and replace the failure components or boards
■ Hot-swap design makes the failure recovery time reduce
greatly, and the system availability can be effectively improved
as a result. The O&M engineers after trained can replace the
failure module of UPS5000-E themselves in few minutes
Hot-swap power
module
Hot-swap bypass
module
Hot-swap energy
control module
2 Huawei UPS5000-E Series Modular Uninterruptible Power System
■ When the load rate is very low (below 10%-15%), intelligent
hibernation can be enabled and some power modules will
switch to "standby" state to boost load rate and improve
operating efficiency
■ To ensure reliability, at least one power module serves as
redundancy module and when load increases dramatically,
the sleep module will be awaked instantly
Bypass
Mains
100%
Load
Module
Module
Module
Module
Module
Module
Module
Module
75%
50%
25%
0%
Maintenance Bypass
Battery
Output
Static Bypass
High Operating Efficiency
■ Due to redundancy configuration to ensure reliability and
excessive configuration at the initial stage to meet the
power demand in 3-5 years, the UPS system of traditional
datacenter often operates at load rate of 10%-40% and
the operating efficiency is far below the value claimed. It's
estimated that the UPS loss takes up 6%-10% of the total
power consumption in datacenter
■ Huawei UPS can keep high efficiency operation at low load
rate: 96% at 40% rated load and 95% at 20% rated load
■ Given 200 kW load and air conditioner with a COP of 3:1,
- 80, 183 kWh can be saved compared to traditional UPS
(92% efficiency)
- 257, 731 kWh can be saved compared to legacy UPS
(86% efficiency)
>> High efficiency at low load rate
>> Intelligent hibernation design
■ In good grid area, ECO mode can be enabled to improve
efficiency to more than 99% and the maximal energy-saving
can be achieved
■ At ECO mode, the load is powered by static bypass (the
allowable input range can be set) and the inverter is in
"standby" state
■ When input abnormality occurs, UPS5000-E will transfer
to online mode in several milliseconds to ensure power
continuity and quality
>> Achieving 99% efficiency at ECO mode
100%
80%
60%
90%
70%
50%
55%
65%
75%
85%
95%
0% 20% 40% 60% 80% 100%
Load rate
Efficiency
3Huawei UPS5000-E Series Modular Uninterruptible Power System
Excellent Usability
■ High power density of up to 320kVA per cabinet, 50%
footprint saving
■ Front accessible maintenance
■ Back-to-wall installation (40-200kVA)
■ Top/bottom cable entry compatible
>> Small footprint and easy construction
■ Automatic switch between float charging and average
charging and temperature compensation
■ Battery hibernation design to avoid long-term float
charging, which improves battery service time greatly
■ Battery failure pre-alarm when its health grade is too low
■ Flexible battery configuration: 30-40 batteries per string
allow customers to get the faulty battery out instead of
replacing it
>> Intelligent battery management, extending battery lifespan
■ THDi<3% & power factor>0.99 reduce the pollution to power grid and lower the expense on power distribution components
including cables, breakers, etc.
■ Power walk-in technology boost the ratio of UPS capacity to D. G. capacity to 1:1.1 and cut the D. G. expense down
>> Low investment on power distribution system
4 Huawei UPS5000-E Series Modular Uninterruptible Power System
Comprehensive Reliability Assurance
Reactive
power (Q )
φ
PF = 0.9
(lagging)
PF = 0.9
(leading)
PF = 0.7
(leading)
PF = 0.5
(leading)
PF = 0.7
(lagging)
PF = 0.5
(lagging)
Ideal Huawei UPS
PF = 1
Active power (P )
■ High output power factor of up to 1, 25% more load driven
than traditional UPSs
The application of PFC technology in modern IT devices like servers,
storages, routers improves the input power factor to more than 0.95.
And if they are powered by UPS with output power factor of 0.7-0.8,
the investment on UPS will increase remarkably
■ No derating for capacitive or inductive devices with a PF>0.5
>> High load adaptability
■ No derating at 40℃ to ensure power continuity
■ Conformal coating on PCB, improving adaptability to dusty
or salty spray environment
>> High environment adaptability
■ 138-485 Vac wide input voltage range to minimize battery
use: 485-305Vac for 100% load; 305-138 Vac for 100%-
40% load (derating linearly)
■ 6 kV/5 kA lightning protection design, reducing lightning-
related failure rate
>> High grid adaptability
100 150 200 250 300 350
Input Voltage Range (V)
Typical UPS Input Voltage Range
Huawei UPS Input Voltage Range
Areas allowing load rate >50%
400 450 500
■ Redundancy design for energy control unit, communication
buses to eliminate single point of failure
■ Fault-tolerant design for fan system: 30% load can be driven
when 2 fans fail and 50% load when 1 fan fails
>> Redundancy design
Redundant Energy
Control Units
Power Module After Airborne
Hygroscopic Dust Test
5Huawei UPS5000-E Series Modular Uninterruptible Power System
Value & Features
High availability, warning and troubleshooting
■ Foresight warning of faults and risks improves IDC availability
■ Quickly faults location, virtual inspection
Smart interaction, energy saving
■ Dynamic PUE management
■ Optimizing important power and cooling services
Rapid deployment, one -button launching
■ Pre-configured software and parameters, one-button launching
■ Parameters of AC and UPS loading, testing time saving
Easy visualization maintenance in 3D view
■ The 3D design tool realizes 3D visual maintenance
■ Dynamic 3D display of site temperature, eliminating hot spots
IP
InternetNetEco
System
Mornitoring
System
PDF
Intelligent Management System
■ iManager NetEco 1000U can run on the Windows operating system and can be accessed through a web browser. The iManager
NetEco 1000U enables you to monitor the key performance indicators (KPIs) and alarms of the UPSs in real time. In addition, it
enables you to remotely control and manage the UPSs. This increases the centralized management and remote operation and
maintenance capabilities for the UPSs. NetEco 1000U supports connection through USB Data lines, RS232 cable, or network cable.
>> NetEco 1000U Introduction
■ NetEco is a new generation data center management
system launched by HUAWEI. It manages the real-time data
and status of data center infrastructures, including power,
environment, video, and door status and generates alarms if
any fault occurs.
■ NetEco displays data center layouts and data reports for
customers to easily query equipment status, and provides a
standard platform to apply to all data center solutions due
to its flexible configuration, smooth capacity expansion, and
hierarchical management.
>> NetEco 6000 Introduction
6 Huawei UPS5000-E Series Modular Uninterruptible Power System
40kVA power module
Static bypass module
Energy control module
Monitoring unit with built-in SNMP and RS485
Mechanical frame
Maintenance bypass switch
7-inch Liquid Crystal Display (LCD)
Dust-proof net
UPS5000-E Composition
1
1
2
2
3
3
8
8
6
6
7
7
4
4
5
5
40-320kVA
7Huawei UPS5000-E Series Modular Uninterruptible Power System
■ Supports 2 UPS5000-Es
paralleled together
■ Built-in 630A/4P ATS
■ Real-time detection about
input parameters and breaker
state
■ Built-in Class C surge
protection device
■ Supports customization as
required
■ Supports 2 UPS5000-Es
paralleled together
■ 8-way output breakers
■ Real-time detection about
input parameters and breaker
state
■ Built-in Class C surge
protection device and residual
current circuit breaker
■ Supports customization as
required
Input power distribution
cabinet (Optional)
Output power distribution
cabinet (Optional)
UPS5000-E Composition
>> Power module
The Power module with rated capacity of 40 kVA/kW can eliminate
all the nine common problems in public grid and output pure and
stable sine wave.
Its dimensions are 130 mm (H) x 442 mm (W)x 620 mm (D).
>> Bypass module
The bypass module can provide continuous power supply to
load when overload. The bypass module of UPS5000-E features
concentrated design and includes 3 models with rated capacity of
200/320/480 kVA separately according to the rack type.
The dimensions of them are 130 mm (H) x 442 mm (W)x 620 mm (D).
>> Energy control module
The ECM supports intra-rack parallel CAN communication and inter-
rack parallel CAN communication. The intra-rack loadshare control
and inter-rack loadshare control are isolated at ECM to achieve better
expandability.
8 Huawei UPS5000-E Series Modular Uninterruptible Power System
Component Function
Antiseismic kit Reinforces the cabinet so that the cabinet meets the requirements of 9 degree seismic fortification intensity.
IP21 component Prevents water from dropping into the cabinet, protecting the cabinet to IP21.
Top outlet kit
If you need to install the cabinet against the wall, install a top outlet kit to meet heat dissipation requirements. It’s
suitable for 40-200kVA.
ECM extended subrack Install this subrack when the UPS5000-E is equipped with a backfeed protection card and dry contact extended card.
Top entry cabinet
Install a top entry cabinet to meet the requirements for routing cables from the top of the UPS5000-E cabinet. It is
suitable for 240-320kVA.
Ambient temperature and
humidity sensor
Battery temperature sensor can detect the battery temperature and provide reference for temperature compensation
when float-charging.
Battery temperature sensor Feedbacks real-time temperature and humidity data to dynamic environment monitoring system.
>> Dry contact extended card (Optional)
The dry contact extended card provides five relay dry contact outputs
and five signal input ports. The card implements additional alarm and
control functions to meet customer requirements.
>> Backfeed protection card (Optional)
The backfeed protection card sends signals to trigger alarm signals or
quickly disconnect the feedback loop
>> Dry contact card
The dry contact card allows the UPS to control and monitor the
switch state of BCB box and implement EPO.
>> Battery ground fault detector
(Optional)
The battery ground fault detector
detects battery ground fault and sends
alarm signals when the ground leakage
current exceeds the threshold value.
>> Battery monitoring unit
(Optional)
Battery monitoring unit supports
detection about the voltages,
charge and discharge currents, and
temperatures of 24 batteries with a
rated voltage of 2–12 V DC.
Other Optional Components
9Huawei UPS5000-E Series Modular Uninterruptible Power System
Model
UPS5000-E-120K-
F120
UPS5000-E-200K-
F200
UPS5000-E-320K-
F320
UPS5000-E-480K-
F480
Rated Capacity (kVA/kW) 40/80/120 40/80/120/160/200
40/80/120/160
/200/240/280/320
40/80/120/160/200/240
/280/320/360/400/440/480
Number of Power Modules 1-3 1-5 1-8 1-12
Input
Mains
Input Wiring 3Ph+N+PE
Rated Voltage 380/400/415Vac
Voltage Range 138-485 Vac (305-485 Vac for 100% load; 138-305 Vac for 40%-100% load)
Input Frequency 40-70 Hz
Total Harmonic
Distortion
THDi<3% for linear load, THDi<5% for nonlinear load
Input Power Factor 0.99
Bypass
Input Wiring 3Ph+N+PE
Rated Voltage 380/400/415 Vac
Input Frequency 50/60±6 Hz
Battery Rated Voltage 360-480 Vdc (the number of batteries can be selected from 30 to 40; 32 batteries in default)
Output
Output Wiring 3Ph+N+PE
Voltage 380/400/415 Vac±1%
Frequency Tracking the bypass input (Online Mode); 50/60 Hz±0.1% (Battery Mode)
Waveform Sine wave (THDv<1% for linear load; THDv<3% for non-linear load)
Output Power Factor 1
Efficiency 96%
Overload Capacity
Inverter: 110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 min
Bypass: 135% overload for long term; <1000% overload for 100ms
Environment
Operating Temperature 0-40℃
Storage Temperature -40-70℃
Relative Humidity 0%-95% (No condensing)
Maximum Operating Altitude 1000 m. Above 1000 m, derating 1% for each additional 100 m
Audible Noise <65dB <68dB <72dB
Others
Height×Width×Depth(mm) 2000×600×850 2000×1200×850
Weight 227-293kg 227-359kg 227-480kg 693-1050kg
Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc.
Communications Dry contacts, RS485, SNMP
Technical Data
10 Huawei UPS5000-E Series Modular Uninterruptible Power System
Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademark Notice
, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd.
Other trademarks, product, service and company names mentioned are the property of their respective owners.
HUAWEI TECHNOLOGIES CO., LTD.
Huawei Industrial Base
Bantian Longgang
Shenzhen 518129, P.R. China
Tel: +86-755-28780808
Version No.: M3-022334-20140207-C-1.0
www.huawei.com
General Disclaimer
THE INFORMATION IN THIS DOCUMENT MAY CONTAIN PREDICTIVE STATEMENTS
INCLUDING, WITHOUT LIMITATION, STATEMENTS REGARDING THE FUTURE FINANCIAL
AND OPERATING RESULTS, FUTURE PRODUCT PORTFOLIO, NEW TECHNOLOGY, ETC.
THERE ARE A NUMBER OF FACTORS THAT COULD CAUSE ACTUAL RESULTS AND
DEVELOPMENTS TO DIFFER MATERIALLY FROM THOSE EXPRESSED OR IMPLIED IN THE
PREDICTIVE STATEMENTS. THEREFORE, SUCH INFORMATION IS PROVIDED FOR REFERENCE
PURPOSE ONLY AND CONSTITUTES NEITHER AN OFFER NOR AN ACCEPTANCE. HUAWEI
MAY CHANGE THE INFORMATION AT ANY TIME WITHOUT NOTICE.

Más contenido relacionado

Destacado

Vital Rural Area Policy Forum 2010 - Smart Cities Customer Insight and deve...
Vital Rural Area Policy Forum 2010   - Smart Cities Customer Insight and deve...Vital Rural Area Policy Forum 2010   - Smart Cities Customer Insight and deve...
Vital Rural Area Policy Forum 2010 - Smart Cities Customer Insight and deve...
Intercommunale Leiedal
 
Guide to Surge Protection Devices
Guide to Surge Protection DevicesGuide to Surge Protection Devices
Guide to Surge Protection Devices
Jason Koffler
 

Destacado (7)

Huawei ups product and solution 02 (20140318)
Huawei ups product and solution 02 (20140318)Huawei ups product and solution 02 (20140318)
Huawei ups product and solution 02 (20140318)
 
Vital Rural Area Policy Forum 2010 - Smart Cities Customer Insight and deve...
Vital Rural Area Policy Forum 2010   - Smart Cities Customer Insight and deve...Vital Rural Area Policy Forum 2010   - Smart Cities Customer Insight and deve...
Vital Rural Area Policy Forum 2010 - Smart Cities Customer Insight and deve...
 
Guide to Surge Protection Devices
Guide to Surge Protection DevicesGuide to Surge Protection Devices
Guide to Surge Protection Devices
 
UPS Electrical Design and Installation
UPS Electrical Design and InstallationUPS Electrical Design and Installation
UPS Electrical Design and Installation
 
Channel Strategy: Framework for Succes
Channel Strategy: Framework for SuccesChannel Strategy: Framework for Succes
Channel Strategy: Framework for Succes
 
K to 12 Mathematics Curriculum Guide for Grades 1 to 10
K to 12 Mathematics Curriculum Guide for Grades 1 to 10K to 12 Mathematics Curriculum Guide for Grades 1 to 10
K to 12 Mathematics Curriculum Guide for Grades 1 to 10
 
MATH Lesson Plan sample for demo teaching
MATH Lesson Plan sample for demo teaching MATH Lesson Plan sample for demo teaching
MATH Lesson Plan sample for demo teaching
 

Similar a Huawei Modular UPS Systems UPS5000E Sereis

Eaton_93E_Brochure_Rev_B_LOW
Eaton_93E_Brochure_Rev_B_LOWEaton_93E_Brochure_Rev_B_LOW
Eaton_93E_Brochure_Rev_B_LOW
Ehab Saleh
 
Delta-Data Center Solutions (1)
Delta-Data Center Solutions (1)Delta-Data Center Solutions (1)
Delta-Data Center Solutions (1)
Joydio Cadayday
 
6dec2011 - Power Back-up_1
6dec2011 - Power Back-up_16dec2011 - Power Back-up_1
6dec2011 - Power Back-up_1
Agora Group
 
Secure Power Design Considerations
Secure Power Design ConsiderationsSecure Power Design Considerations
Secure Power Design Considerations
Schneider Electric
 
Poweredge Complete Profile 2015
Poweredge Complete Profile 2015Poweredge Complete Profile 2015
Poweredge Complete Profile 2015
Allyn Jame Nuevo
 
Eaton 93PM 30-50kW UPS.pptx
Eaton 93PM 30-50kW UPS.pptxEaton 93PM 30-50kW UPS.pptx
Eaton 93PM 30-50kW UPS.pptx
mancangkul1
 
Sales Trng Product Power
Sales Trng Product  PowerSales Trng Product  Power
Sales Trng Product Power
rkonte
 

Similar a Huawei Modular UPS Systems UPS5000E Sereis (20)

ZH/PVII Series UPS 10-600kVA from HRD UPS -20160303
ZH/PVII Series UPS 10-600kVA from HRD UPS -20160303ZH/PVII Series UPS 10-600kVA from HRD UPS -20160303
ZH/PVII Series UPS 10-600kVA from HRD UPS -20160303
 
Eaton_93E_Brochure_Rev_B_LOW
Eaton_93E_Brochure_Rev_B_LOWEaton_93E_Brochure_Rev_B_LOW
Eaton_93E_Brochure_Rev_B_LOW
 
Modular ups
Modular upsModular ups
Modular ups
 
Delta-Data Center Solutions (1)
Delta-Data Center Solutions (1)Delta-Data Center Solutions (1)
Delta-Data Center Solutions (1)
 
Solar String Inverter - InPhase Power
Solar String Inverter - InPhase PowerSolar String Inverter - InPhase Power
Solar String Inverter - InPhase Power
 
6dec2011 - Power Back-up_1
6dec2011 - Power Back-up_16dec2011 - Power Back-up_1
6dec2011 - Power Back-up_1
 
Central Grid Tie Solar Inverter - InPhase Power
Central Grid Tie Solar Inverter - InPhase PowerCentral Grid Tie Solar Inverter - InPhase Power
Central Grid Tie Solar Inverter - InPhase Power
 
Secure Power Design Considerations
Secure Power Design ConsiderationsSecure Power Design Considerations
Secure Power Design Considerations
 
Riello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheetRiello multi-power-modular-ups-datasheet
Riello multi-power-modular-ups-datasheet
 
How to enhance hyperconvergence with infrastructure management
How to enhance hyperconvergence with infrastructure managementHow to enhance hyperconvergence with infrastructure management
How to enhance hyperconvergence with infrastructure management
 
3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf
3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf
3 Phase Hybrid Solar Inverters Hybrid Inverter Bidirectional PCU.pdf
 
Poweredge Complete Profile 2015
Poweredge Complete Profile 2015Poweredge Complete Profile 2015
Poweredge Complete Profile 2015
 
Power-One
Power-OnePower-One
Power-One
 
Eaton 93PM 30-50kW UPS.pptx
Eaton 93PM 30-50kW UPS.pptxEaton 93PM 30-50kW UPS.pptx
Eaton 93PM 30-50kW UPS.pptx
 
LP-Series-brochure.pdf
LP-Series-brochure.pdfLP-Series-brochure.pdf
LP-Series-brochure.pdf
 
SITOP_power_supply_en.pdf
SITOP_power_supply_en.pdfSITOP_power_supply_en.pdf
SITOP_power_supply_en.pdf
 
Sales Trng Product Power
Sales Trng Product  PowerSales Trng Product  Power
Sales Trng Product Power
 
report on the Techno india network
report on the Techno india networkreport on the Techno india network
report on the Techno india network
 
 Running UPS in Economy Mode To Save Energy
 Running UPS in Economy Mode To Save Energy Running UPS in Economy Mode To Save Energy
 Running UPS in Economy Mode To Save Energy
 
An overview of Eaton's Utility segment solutions
An overview of Eaton's Utility segment solutionsAn overview of Eaton's Utility segment solutions
An overview of Eaton's Utility segment solutions
 

Último

Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
jaanualu31
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
mphochane1998
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
Epec Engineered Technologies
 

Último (20)

S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptxS1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
S1S2 B.Arch MGU - HOA1&2 Module 3 -Temple Architecture of Kerala.pptx
 
Online electricity billing project report..pdf
Online electricity billing project report..pdfOnline electricity billing project report..pdf
Online electricity billing project report..pdf
 
AIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech studentsAIRCANVAS[1].pdf mini project for btech students
AIRCANVAS[1].pdf mini project for btech students
 
Computer Networks Basics of Network Devices
Computer Networks  Basics of Network DevicesComputer Networks  Basics of Network Devices
Computer Networks Basics of Network Devices
 
Engineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planesEngineering Drawing focus on projection of planes
Engineering Drawing focus on projection of planes
 
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced LoadsFEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
FEA Based Level 3 Assessment of Deformed Tanks with Fluid Induced Loads
 
Work-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptxWork-Permit-Receiver-in-Saudi-Aramco.pptx
Work-Permit-Receiver-in-Saudi-Aramco.pptx
 
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills KuwaitKuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
Kuwait City MTP kit ((+919101817206)) Buy Abortion Pills Kuwait
 
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments""Lesotho Leaps Forward: A Chronicle of Transformative Developments"
"Lesotho Leaps Forward: A Chronicle of Transformative Developments"
 
Wadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptxWadi Rum luxhotel lodge Analysis case study.pptx
Wadi Rum luxhotel lodge Analysis case study.pptx
 
Employee leave management system project.
Employee leave management system project.Employee leave management system project.
Employee leave management system project.
 
Introduction to Serverless with AWS Lambda
Introduction to Serverless with AWS LambdaIntroduction to Serverless with AWS Lambda
Introduction to Serverless with AWS Lambda
 
Thermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - VThermal Engineering-R & A / C - unit - V
Thermal Engineering-R & A / C - unit - V
 
Generative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPTGenerative AI or GenAI technology based PPT
Generative AI or GenAI technology based PPT
 
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
Navigating Complexity: The Role of Trusted Partners and VIAS3D in Dassault Sy...
 
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptxOrlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
Orlando’s Arnold Palmer Hospital Layout Strategy-1.pptx
 
Standard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power PlayStandard vs Custom Battery Packs - Decoding the Power Play
Standard vs Custom Battery Packs - Decoding the Power Play
 
A Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna MunicipalityA Study of Urban Area Plan for Pabna Municipality
A Study of Urban Area Plan for Pabna Municipality
 
Thermal Engineering Unit - I & II . ppt
Thermal Engineering  Unit - I & II . pptThermal Engineering  Unit - I & II . ppt
Thermal Engineering Unit - I & II . ppt
 
DC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equationDC MACHINE-Motoring and generation, Armature circuit equation
DC MACHINE-Motoring and generation, Armature circuit equation
 

Huawei Modular UPS Systems UPS5000E Sereis

  • 1. HUAWEI TECHNOLOGIES CO., LTD. Huawei UPS5000-E Series 40-480kVA Modular Uninterruptible Power System
  • 2. Corporate Information Globalization, localization Market & Management ■ Leading global ICT solution provider ■ Major contributor of telecom standard, first share of many products and solutions ■ Create value for customers continuously for 20 years, grow steadily for 20 years ■ Sales revenue reached CNY 220.2 billion in 2012 ■ There BGs (carrier BG, enterprise BG, consumer BG) were founded in 2011, the enterprise BG and consumer BG grow fast and become two new and stable economic growth points of the group Sales revenue (CNY 0.1 billion) 2007 2008 2009 2010 2011 2012 2202 2039 1825 1466 1231 922 Shenzhen Headquarters Account sharing center Bidding center Logistic center, transfer station R&D center Training center Technical support center Huawei is a leading global ICT solutions provider. Through our dedication to customer-centric innovation and strong partnerships, we have established end-to-end capabilities and strengths across the carrier networks, enterprise, consumer, and cloud computing fields. Huawei is among the world top 500 enterprises, our products and solutions have been deployed in over 140 countries, serving more than one third of the world's population. There are total 155,000 employees working here. About Huawei Network Energy Mexico Netherland Germany Brazil Argentina Hungary Romania India China Bahrain MalaysiaUnited Arab Emirates Mauritius •• 20 global R&D centers •• 45 global training centers •• 130+ service branches •• 13 global customized centers •• 27,000+ stuffs for service •• 3,500 certification partners •• 50,000 certification engineers from partners San Diego USA Dallas USA Moscow Russia Bangalore India Stockholm/Goteborg Sweden Munich Germany
  • 3. ■ Huawei 5000-E "Data Center Product Excellence Award" ■ CommunicAsia "Green science and Technology Award" ■ DCD Data Center "The blueprint Award" ■ "Energy star" certification ■ Deutsche Telekom "The best site design award" ■ "Desktop cloud container data center" Uptime Institute TIER3 certification Supply chain center R&D center Shenzhen supply center India supply center Shenzhen Chengdu Nanjing Xi'an Stockholm Sweden Nuremburg Germany Beijing Wuhan Shanghai Network energy productline is one of four main productlines in Carrier BG. We are committed to help our customer build strong infrastructures for network and protect the long-term investment in energy infrastructure through providing efficient, reliable and intelligent network energy. Huawei network energy productline takes full advantage of the Global intellectual resources and 9 R&D centers have been set up at Germany (Nuremberg), Sweden (Stockholm) and China. As far as the end of 2012, network energy productline had filed 550+ patent applications and the sales revenue had reached 1 billon US dollars. Huawei Network Energy Network Energy Product NetEco Intelligent management system Embedded power (30~400A) Outdoor power (30~600A) Indoor power (100~24000A) Site power Diesel hybrid Solar hybrid Grid hybrid Hybrid power Modular and container DC UPS (1~800kVA) Row/room level precision air conditioner (20~150kw) Data center UPS & air conditioner Hungary supply center Mexico supply center Brazil supply center Distribution center in Netherland and Dubai
  • 4. UPS5000-E Overview............................................. 1 Ultra-high Availability ............................................ 2 High Operating Efficiency ...................................... 3 Excellent Usability.................................................. 4 Comprehensive Reliability Assurance ..................... 5 Intelligent Management System ............................ 6 UPS5000-E Composition........................................ 7 Technical Data..................................................... 10 Contents
  • 5. UPS5000-E Overview Rated Capacity: 40-480kVA (1-12 power modules) Rated Voltage: 380/400/415 Vac Rated Frequency: 50/60 Hz Type: Online, double-conversion, modular Application scenarios: ■ Financial datacenter ■ Internet datacenter ■ Disaster recovery datacenter ■ Telecom central offices 1Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 6. Ultra-high Availability Smooth capacity expansion ■ To avoid power interruption risk in capacity expansion, the capacity of UPS system is planned large enough to meet the power demand in 3-5 years, which leads to low efficiency operation at the initial stage due to low load rate ■ UPS5000-E uses module design and all of power module, bypass module, and control module support hot-swap, which makes smooth capacity expansion according to demand possible and reduces the initial investment >> All hot-swap module design Online maintenance, reducing MTTR greatly ■ Availability is used to weight the degree that a system, subsystem or equipment is in operable and committable state. It's positively related to MTBF (Mean Time Between Failures) and negatively related to MTTR (Mean Time To Repair) ■ For traditional UPS, customers need seek help from the suppliers and long recovery time is required because in maintenance engineers need shutdown and dismantle the UPS, and replace the failure components or boards ■ Hot-swap design makes the failure recovery time reduce greatly, and the system availability can be effectively improved as a result. The O&M engineers after trained can replace the failure module of UPS5000-E themselves in few minutes Hot-swap power module Hot-swap bypass module Hot-swap energy control module 2 Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 7. ■ When the load rate is very low (below 10%-15%), intelligent hibernation can be enabled and some power modules will switch to "standby" state to boost load rate and improve operating efficiency ■ To ensure reliability, at least one power module serves as redundancy module and when load increases dramatically, the sleep module will be awaked instantly Bypass Mains 100% Load Module Module Module Module Module Module Module Module 75% 50% 25% 0% Maintenance Bypass Battery Output Static Bypass High Operating Efficiency ■ Due to redundancy configuration to ensure reliability and excessive configuration at the initial stage to meet the power demand in 3-5 years, the UPS system of traditional datacenter often operates at load rate of 10%-40% and the operating efficiency is far below the value claimed. It's estimated that the UPS loss takes up 6%-10% of the total power consumption in datacenter ■ Huawei UPS can keep high efficiency operation at low load rate: 96% at 40% rated load and 95% at 20% rated load ■ Given 200 kW load and air conditioner with a COP of 3:1, - 80, 183 kWh can be saved compared to traditional UPS (92% efficiency) - 257, 731 kWh can be saved compared to legacy UPS (86% efficiency) >> High efficiency at low load rate >> Intelligent hibernation design ■ In good grid area, ECO mode can be enabled to improve efficiency to more than 99% and the maximal energy-saving can be achieved ■ At ECO mode, the load is powered by static bypass (the allowable input range can be set) and the inverter is in "standby" state ■ When input abnormality occurs, UPS5000-E will transfer to online mode in several milliseconds to ensure power continuity and quality >> Achieving 99% efficiency at ECO mode 100% 80% 60% 90% 70% 50% 55% 65% 75% 85% 95% 0% 20% 40% 60% 80% 100% Load rate Efficiency 3Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 8. Excellent Usability ■ High power density of up to 320kVA per cabinet, 50% footprint saving ■ Front accessible maintenance ■ Back-to-wall installation (40-200kVA) ■ Top/bottom cable entry compatible >> Small footprint and easy construction ■ Automatic switch between float charging and average charging and temperature compensation ■ Battery hibernation design to avoid long-term float charging, which improves battery service time greatly ■ Battery failure pre-alarm when its health grade is too low ■ Flexible battery configuration: 30-40 batteries per string allow customers to get the faulty battery out instead of replacing it >> Intelligent battery management, extending battery lifespan ■ THDi<3% & power factor>0.99 reduce the pollution to power grid and lower the expense on power distribution components including cables, breakers, etc. ■ Power walk-in technology boost the ratio of UPS capacity to D. G. capacity to 1:1.1 and cut the D. G. expense down >> Low investment on power distribution system 4 Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 9. Comprehensive Reliability Assurance Reactive power (Q ) φ PF = 0.9 (lagging) PF = 0.9 (leading) PF = 0.7 (leading) PF = 0.5 (leading) PF = 0.7 (lagging) PF = 0.5 (lagging) Ideal Huawei UPS PF = 1 Active power (P ) ■ High output power factor of up to 1, 25% more load driven than traditional UPSs The application of PFC technology in modern IT devices like servers, storages, routers improves the input power factor to more than 0.95. And if they are powered by UPS with output power factor of 0.7-0.8, the investment on UPS will increase remarkably ■ No derating for capacitive or inductive devices with a PF>0.5 >> High load adaptability ■ No derating at 40℃ to ensure power continuity ■ Conformal coating on PCB, improving adaptability to dusty or salty spray environment >> High environment adaptability ■ 138-485 Vac wide input voltage range to minimize battery use: 485-305Vac for 100% load; 305-138 Vac for 100%- 40% load (derating linearly) ■ 6 kV/5 kA lightning protection design, reducing lightning- related failure rate >> High grid adaptability 100 150 200 250 300 350 Input Voltage Range (V) Typical UPS Input Voltage Range Huawei UPS Input Voltage Range Areas allowing load rate >50% 400 450 500 ■ Redundancy design for energy control unit, communication buses to eliminate single point of failure ■ Fault-tolerant design for fan system: 30% load can be driven when 2 fans fail and 50% load when 1 fan fails >> Redundancy design Redundant Energy Control Units Power Module After Airborne Hygroscopic Dust Test 5Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 10. Value & Features High availability, warning and troubleshooting ■ Foresight warning of faults and risks improves IDC availability ■ Quickly faults location, virtual inspection Smart interaction, energy saving ■ Dynamic PUE management ■ Optimizing important power and cooling services Rapid deployment, one -button launching ■ Pre-configured software and parameters, one-button launching ■ Parameters of AC and UPS loading, testing time saving Easy visualization maintenance in 3D view ■ The 3D design tool realizes 3D visual maintenance ■ Dynamic 3D display of site temperature, eliminating hot spots IP InternetNetEco System Mornitoring System PDF Intelligent Management System ■ iManager NetEco 1000U can run on the Windows operating system and can be accessed through a web browser. The iManager NetEco 1000U enables you to monitor the key performance indicators (KPIs) and alarms of the UPSs in real time. In addition, it enables you to remotely control and manage the UPSs. This increases the centralized management and remote operation and maintenance capabilities for the UPSs. NetEco 1000U supports connection through USB Data lines, RS232 cable, or network cable. >> NetEco 1000U Introduction ■ NetEco is a new generation data center management system launched by HUAWEI. It manages the real-time data and status of data center infrastructures, including power, environment, video, and door status and generates alarms if any fault occurs. ■ NetEco displays data center layouts and data reports for customers to easily query equipment status, and provides a standard platform to apply to all data center solutions due to its flexible configuration, smooth capacity expansion, and hierarchical management. >> NetEco 6000 Introduction 6 Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 11. 40kVA power module Static bypass module Energy control module Monitoring unit with built-in SNMP and RS485 Mechanical frame Maintenance bypass switch 7-inch Liquid Crystal Display (LCD) Dust-proof net UPS5000-E Composition 1 1 2 2 3 3 8 8 6 6 7 7 4 4 5 5 40-320kVA 7Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 12. ■ Supports 2 UPS5000-Es paralleled together ■ Built-in 630A/4P ATS ■ Real-time detection about input parameters and breaker state ■ Built-in Class C surge protection device ■ Supports customization as required ■ Supports 2 UPS5000-Es paralleled together ■ 8-way output breakers ■ Real-time detection about input parameters and breaker state ■ Built-in Class C surge protection device and residual current circuit breaker ■ Supports customization as required Input power distribution cabinet (Optional) Output power distribution cabinet (Optional) UPS5000-E Composition >> Power module The Power module with rated capacity of 40 kVA/kW can eliminate all the nine common problems in public grid and output pure and stable sine wave. Its dimensions are 130 mm (H) x 442 mm (W)x 620 mm (D). >> Bypass module The bypass module can provide continuous power supply to load when overload. The bypass module of UPS5000-E features concentrated design and includes 3 models with rated capacity of 200/320/480 kVA separately according to the rack type. The dimensions of them are 130 mm (H) x 442 mm (W)x 620 mm (D). >> Energy control module The ECM supports intra-rack parallel CAN communication and inter- rack parallel CAN communication. The intra-rack loadshare control and inter-rack loadshare control are isolated at ECM to achieve better expandability. 8 Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 13. Component Function Antiseismic kit Reinforces the cabinet so that the cabinet meets the requirements of 9 degree seismic fortification intensity. IP21 component Prevents water from dropping into the cabinet, protecting the cabinet to IP21. Top outlet kit If you need to install the cabinet against the wall, install a top outlet kit to meet heat dissipation requirements. It’s suitable for 40-200kVA. ECM extended subrack Install this subrack when the UPS5000-E is equipped with a backfeed protection card and dry contact extended card. Top entry cabinet Install a top entry cabinet to meet the requirements for routing cables from the top of the UPS5000-E cabinet. It is suitable for 240-320kVA. Ambient temperature and humidity sensor Battery temperature sensor can detect the battery temperature and provide reference for temperature compensation when float-charging. Battery temperature sensor Feedbacks real-time temperature and humidity data to dynamic environment monitoring system. >> Dry contact extended card (Optional) The dry contact extended card provides five relay dry contact outputs and five signal input ports. The card implements additional alarm and control functions to meet customer requirements. >> Backfeed protection card (Optional) The backfeed protection card sends signals to trigger alarm signals or quickly disconnect the feedback loop >> Dry contact card The dry contact card allows the UPS to control and monitor the switch state of BCB box and implement EPO. >> Battery ground fault detector (Optional) The battery ground fault detector detects battery ground fault and sends alarm signals when the ground leakage current exceeds the threshold value. >> Battery monitoring unit (Optional) Battery monitoring unit supports detection about the voltages, charge and discharge currents, and temperatures of 24 batteries with a rated voltage of 2–12 V DC. Other Optional Components 9Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 14. Model UPS5000-E-120K- F120 UPS5000-E-200K- F200 UPS5000-E-320K- F320 UPS5000-E-480K- F480 Rated Capacity (kVA/kW) 40/80/120 40/80/120/160/200 40/80/120/160 /200/240/280/320 40/80/120/160/200/240 /280/320/360/400/440/480 Number of Power Modules 1-3 1-5 1-8 1-12 Input Mains Input Wiring 3Ph+N+PE Rated Voltage 380/400/415Vac Voltage Range 138-485 Vac (305-485 Vac for 100% load; 138-305 Vac for 40%-100% load) Input Frequency 40-70 Hz Total Harmonic Distortion THDi<3% for linear load, THDi<5% for nonlinear load Input Power Factor 0.99 Bypass Input Wiring 3Ph+N+PE Rated Voltage 380/400/415 Vac Input Frequency 50/60±6 Hz Battery Rated Voltage 360-480 Vdc (the number of batteries can be selected from 30 to 40; 32 batteries in default) Output Output Wiring 3Ph+N+PE Voltage 380/400/415 Vac±1% Frequency Tracking the bypass input (Online Mode); 50/60 Hz±0.1% (Battery Mode) Waveform Sine wave (THDv<1% for linear load; THDv<3% for non-linear load) Output Power Factor 1 Efficiency 96% Overload Capacity Inverter: 110% overload for 60 min; 125% overload for 10 min; 150% overload for 1 min Bypass: 135% overload for long term; <1000% overload for 100ms Environment Operating Temperature 0-40℃ Storage Temperature -40-70℃ Relative Humidity 0%-95% (No condensing) Maximum Operating Altitude 1000 m. Above 1000 m, derating 1% for each additional 100 m Audible Noise <65dB <68dB <72dB Others Height×Width×Depth(mm) 2000×600×850 2000×1200×850 Weight 227-293kg 227-359kg 227-480kg 693-1050kg Certifications EN/IEC 62040-1; EN/IEC 62040-2; EN/IEC 62040-3; CE; CB; RoHS, REACH, WEEE, etc. Communications Dry contacts, RS485, SNMP Technical Data 10 Huawei UPS5000-E Series Modular Uninterruptible Power System
  • 15.
  • 16. Copyright © Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademark Notice , HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned are the property of their respective owners. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 Version No.: M3-022334-20140207-C-1.0 www.huawei.com General Disclaimer THE INFORMATION IN THIS DOCUMENT MAY CONTAIN PREDICTIVE STATEMENTS INCLUDING, WITHOUT LIMITATION, STATEMENTS REGARDING THE FUTURE FINANCIAL AND OPERATING RESULTS, FUTURE PRODUCT PORTFOLIO, NEW TECHNOLOGY, ETC. THERE ARE A NUMBER OF FACTORS THAT COULD CAUSE ACTUAL RESULTS AND DEVELOPMENTS TO DIFFER MATERIALLY FROM THOSE EXPRESSED OR IMPLIED IN THE PREDICTIVE STATEMENTS. THEREFORE, SUCH INFORMATION IS PROVIDED FOR REFERENCE PURPOSE ONLY AND CONSTITUTES NEITHER AN OFFER NOR AN ACCEPTANCE. HUAWEI MAY CHANGE THE INFORMATION AT ANY TIME WITHOUT NOTICE.