Steam
Generator
Contact: Scott D. Portzline
sdportzline1@verizon.net
• There is a risky and dangerous unanalyzed safety
condition involving the steam generators.
• The steam generators could fail and stop removing
heat from the reactor.
• The problematic behavior is not predictable by
standard engineering analyses.
• Excessive fluttering of the steam tubes could occur
when the reactor systems are challenged.
• The steam generators could self-destruct.
• Result in a "containment bypass accident."
• A large amount of radiation is released without any
time for an evacuation.
TMI Unit #1
“Consequential steam generator tube ruptures
are potentially risk-significant events because
thermally induced SG tube failures caused by hot
gases from a damaged reactor core can result in a
containment bypass event and a large release of
fission products to the environment.”
source: Nuclear Regulatory Commission
NUREG-2195, May 2018
Video: Fluttering of the Steam Tubes
Reactor
SteamGenerator1
SteamGenerator2
Reactor
Coolant
Pump
Reactor
Coolant
Pump
Steam
Tubes
Each Steam Generator is 72 feet tall and
packed with 15,597 vertically oriented
Steam Tubes which are 56 feet in length.
A section of Steam Tubes
Tube Support Plate
Tube Support Plate
3to4feet
Top view from exelon
Top view SG “B”
15,597 Steam Tubes 183 are damaged by
tube-to-tube wear
Top view
The walls of the steam tubes
are 2/3rds the thickness of a dime.
Steam
Tube
The walls of the steam tubes
are 2/3rds the thickness of a dime.
Think of a steam generator as a heat
exchanger. The steam tubes (in red)
conveying the reactor coolant are
separated by gaps through which a
separate supply of water is pumped in an
upward direction. This water is used to
create steam.
This is how the heat is exchanged from the
reactor coolant to the water used for the
steam.
Side view
Top view
Steam generators are the primary method
of cooling a reactor and as such are a very
important safety component.
Video: Turbulence Is Causing The Fluttering
Feedback Mechanism
“The more you have motion [of the steam tubes],
the more you have hydraulic excitation. The more
you have hydraulic excitation, the more you've got
motion.”
Principal Research Engineer
Atomic Energy of Canada
source: Nuclear Regulatory Commission
briefing transcript, Feb. 7, 2013
Not Reviewed by the NRC
source: Nuclear Regulatory Commission
briefing transcript, Feb. 7, 2013
“For the steam generators, the thermal hydraulic
conditions on the secondary side are not something
that’s within our standard review plan.”
Nuclear Reactor Regulations
Reactor Systems Branch Chief
TMI Alert contends that an analysis must be performed on the
steam tubes for transient conditions based on direct input from
the plant system thermal hydraulic analyses.
Because TMI Unit #1 has already experienced unexpected
steam tube damage as the result of fluttering, there appears to
be a significant increased risk of an accident and a significant
increase in the consequences of such an accident.
The NRC considers a steam tube rupture
an “accident” because it leaks reactor
coolant into the steam supply.
Steam tubes are an integral part of the reactor
coolant pressure boundary and as such, are relied
upon to maintain the reactor system's pressure and
coolant inventory.
The rupture of multiple steam tubes results in a
large break loss-of-coolant accident. Steam tube
ruptures can be the cause of a severe accident and
radiological release.
• “These [spontaneous] ruptures have caused
complex plant transients which have not always
been easy for the reactor operators to control.
• A continuing issue has been - exactly what
constitutes an appropriate and timely inspection
and which degraded tubes are still fit for service.
• The most widely used inspection equipment is
not able to detect and size all the degradation of
concern.”
source: Idaho National Laboratory
NUREG-6365, April 1996
The rupture of the steam tubes “can result in a
containment bypass event and a large release of
fission products to the environment.”
NUREG-2195
This scenario is called a “containment bypass accident”
because a pathway is created for radiation to escape out
of the containment building and into the environment.
Reactor coolant jetting
from a ruptured steam tube.
Containment Bypass Accident
Turbine Building
Three Mile Island Unit #1
Tube-to-Tube Wear
bowing + fluttering
Steam Generator
Image source: Nuclear Regulatory Commission
briefing 2/7/2013 - Steam Generator Tube Degradation
A total of 257 steam
tubes showed signs of
tube-to-tube wear.
A few were
approximately 20%
through the tube wall.
Fluttering
Fluttering
The damage done to TMI’s steam tubes was
caused by mistakes made by AREVA, the
French manufacturer of the steam generators.
• DESIGN FLAW
• MANUFACTURING DEFECT
• OVERLY AGGRESSIVE DESIGN
Steam Generator
1. Design Flaw
thermal expansion rates
Steam Generator
When operating, the steam generator shell
stays cooler than expected. The steam tubes
expand at a greater rate than the shell. The
result is that the tubes experience higher
compressive loads from end-to-end than
planned. This results in bowing of the tubes.
Root Cause
“During a transient condition the
thermal expansion can be significant.”
Steam Generator Integrity Assessment
Guidelines Revision 3, Electric Power
Research Institute
2. Manufacturing Defect
Steam Generator
The steam generators were not constructed
as designed. Specifically, the preload tensile
value of the steam tubes was less than called
for by the design specification. The result is
the steam tubes experience a higher
compressive load than planned.
Root Cause
3. Overly Aggressive Design
Steam Generator
• The margin to steam tube bowing was not
conservative.
• The steam tube walls are thinner than the
previous design.
• The steam tubes are smaller in diameter
and packed together tighter than in previous
designs. The gap between the tubes is only
1/8 inch when the reactor is operating at
normal temperatures.
Root Cause
Steam Generator
• The margin to steam tube bowing was not
conservative.
• The steam tube walls are thinner than the
previous design.
• The steam tubes are smaller in diameter
and packed together tighter than in previous
designs. The gap between the tubes is only
1/8 inch when the reactor is operating at
normal temperatures.
3. Overly Aggressive Design
Root Cause
Steam Generator
• The margin to steam tube bowing was not
conservative.
• The steam tube walls are thinner than the
previous design.
• The steam tubes are smaller in diameter and
packed together tighter than in previous designs.
The gap between the tubes is only 1/8 inch when
the reactor is operating at normal temperatures.
Therefore, these three specifications,
produced by intentional design, make any
tube-to-tube wear of even greater concern
regarding steam tube ruptures.
Root Cause
3. Overly Aggressive Design
Alloy 690
• The new metal Alloy 690 used to manufacture the steam tubes is
less resistant to stress corrosion cracking, but it frets, pits and
wears faster that the metal used in previous designs (Alloy 600).
• As time goes by there is a greater risk of tube cracking and rupture.
“Through these experiments, it is
found that the fretting fatigue
strength decreased about 43%
compared to the plain fatigue
strength…. oblique micro-cracks
are initiated at an earlier stage.”
Fretting wear
source: A Study on Fretting Behavior in
Room Temperature for Inconel Alloy 690
Under reactor transient conditions, the
steam generators could self-destruct
due to fluttering steam tubes.
Steam Genrator
At TMI Unit #1 steam tube flutter is created by the
turbulent and chaotic flow of the secondary system
water between the tubes (thermal hydraulic
conditions).
Under higher temperatures, the energy of the
flutter could impart severe damage to many steam
tubes, including ones that were not effected during
normal operating temperatures. This represents a
hidden consequence of the new design.
Under reactor transient conditions, the
steam generators could self-destruct
due to fluttering steam tubes.
Steam Genrator
At TMI Unit #1 steam tube flutter is created by the
turbulent and chaotic flow of the secondary system
water between the tubes (thermal hydraulic
conditions).
Under higher temperatures, the energy of the
flutter could impart severe damage to many steam
tubes, including ones that were not effected during
normal operating temperatures. This represents a
hidden consequence of the new design.
• Greater number of tubes bowing
• Greater severity of the bowing
• Changes in geometry of the SG due to narrowing of the tube gaps
• Greater velocity of water between the tubes
• Greater amount of energy of the flutter (lateral accelerations)
• Flutter could become more chaotic
• The effects of harmonic resonance disturbance
• Additional damage to the steam tubes at the Tube Support Plates
TMI Alert expects these conditions and behaviors to be
analyzed under reactor transient conditions:
• Greater number of tubes bowing
• Greater severity of the bowing
• Changes in geometry of the SG due to narrowing of the tube gaps
• Greater velocity of water between the tubes
• Greater amount of energy of the flutter (lateral accelerations)
• Flutter could become more chaotic
• The effects of harmonic resonance disturbance
• Additional damage to the steam tubes at the Tube Support Plates
TMI Alert expects these conditions and behaviors to be
analyzed under reactor transient conditions:
Tube Support
Plate
Design changes went too far!
TMI Alert asserts that the design changes of the replacement
steam generators, primarily the geometry of the internal
components,
• the steam tube size
• reduced gap between the steam tubes
constitutes a violation of the NRC regulation on changes.
• regulation §50.59 in 10 CFR "Changes, tests and experiments."
San Onofre Defective Steam Generators
• At the San Onofre Nuclear Generating Station, tube-to-tube wear
caused the degradation of their replacement steam generators.
• A design error resulted in the actual steam generators having
more severe thermal-hydraulic conditions than expected, which
contributed, along with other factors, to the rapid steam tube
wall degradation.
• The steam tube walls at TMI are 20% thinner than at San Onofre.
Incremental changes
Nuclear plants are allowed to make small changes to their reactor
components and safety systems without amending their license.
However, a series of small changes in one component can add up
to a risky and dangerous defect. As the conservative margin for
safety and reliability is decreased in the pursuit of efficiency, the
line delineating safe from unsafe designs grows ever closer. At
some point, safety systems will not be able to perform their
functions under stressful loads or conditions.
Some of these defects can be hidden from detection under
normal testing and analysis; even for the analytical methods
approved by the industry.
SAFE UNSAFE

Más contenido relacionado

La actualidad más candente

THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
Sayeed Mohammed
 
Installation of hot water supply for hotel (recovered)
Installation of hot water supply for hotel (recovered)Installation of hot water supply for hotel (recovered)
Installation of hot water supply for hotel (recovered)
tfkc1212
 
Sem 2 bs1 Hot water supply system 2
Sem 2 bs1 Hot water supply system 2Sem 2 bs1 Hot water supply system 2
Sem 2 bs1 Hot water supply system 2
Est
 

La actualidad más candente (20)

THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
THERMAL ANALYSIS AND DESIGN OF A NATURAL DRAFT COOLING TOWER OF A 1000 MW NUC...
 
Heat emitters
Heat emittersHeat emitters
Heat emitters
 
Leak testing-steam-turbine-condensers-application
Leak testing-steam-turbine-condensers-applicationLeak testing-steam-turbine-condensers-application
Leak testing-steam-turbine-condensers-application
 
Superhtr
SuperhtrSuperhtr
Superhtr
 
heating-cooling units
heating-cooling unitsheating-cooling units
heating-cooling units
 
Boiler Superheater Design Modification
Boiler Superheater Design ModificationBoiler Superheater Design Modification
Boiler Superheater Design Modification
 
Case studies in boiler vibration and BFP cavitation by k.k.parthiban
Case studies in boiler vibration and BFP cavitation by k.k.parthibanCase studies in boiler vibration and BFP cavitation by k.k.parthiban
Case studies in boiler vibration and BFP cavitation by k.k.parthiban
 
Installation of hot water supply for hotel (recovered)
Installation of hot water supply for hotel (recovered)Installation of hot water supply for hotel (recovered)
Installation of hot water supply for hotel (recovered)
 
Materials used in boiler & furnace
Materials used in boiler & furnaceMaterials used in boiler & furnace
Materials used in boiler & furnace
 
FYPP
FYPPFYPP
FYPP
 
Hot Water Supply Report BS1
Hot Water Supply Report BS1Hot Water Supply Report BS1
Hot Water Supply Report BS1
 
Hughes EXP-MH-14K-350 Tank Shower
Hughes EXP-MH-14K-350 Tank ShowerHughes EXP-MH-14K-350 Tank Shower
Hughes EXP-MH-14K-350 Tank Shower
 
Central heating level 3
Central heating level 3Central heating level 3
Central heating level 3
 
Sem 2 bs1 Hot water supply system 2
Sem 2 bs1 Hot water supply system 2Sem 2 bs1 Hot water supply system 2
Sem 2 bs1 Hot water supply system 2
 
Ground Source Energy - System Design
Ground Source Energy - System DesignGround Source Energy - System Design
Ground Source Energy - System Design
 
Thermo acoustic refrigeration
Thermo acoustic refrigerationThermo acoustic refrigeration
Thermo acoustic refrigeration
 
Ea igshpa-kering-presentation2 (1)
Ea igshpa-kering-presentation2 (1)Ea igshpa-kering-presentation2 (1)
Ea igshpa-kering-presentation2 (1)
 
Materials
MaterialsMaterials
Materials
 
T3 Swimming Pool Heat Pump Brochure-BLUEWAY
T3 Swimming Pool Heat Pump Brochure-BLUEWAYT3 Swimming Pool Heat Pump Brochure-BLUEWAY
T3 Swimming Pool Heat Pump Brochure-BLUEWAY
 
Surging & blow out of loop seals in a CFBC boiler
Surging & blow out of loop seals in a CFBC boilerSurging & blow out of loop seals in a CFBC boiler
Surging & blow out of loop seals in a CFBC boiler
 

Similar a Three Mile Island Nuclear Plant steam generator safety is suspect

BTL Steag Presentation for improving the reliability
BTL Steag Presentation for improving the reliabilityBTL Steag Presentation for improving the reliability
BTL Steag Presentation for improving the reliability
abhilashg51
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plants
SHIVAJI CHOUDHURY
 
Remaining life assessment of refinery furnace tubes using finite element method
Remaining life assessment of refinery furnace tubes using finite element methodRemaining life assessment of refinery furnace tubes using finite element method
Remaining life assessment of refinery furnace tubes using finite element method
Barhm Mohamad
 

Similar a Three Mile Island Nuclear Plant steam generator safety is suspect (20)

Three Mile Island’s new steam generator tubes could fail
Three Mile Island’s new steam generator tubes could failThree Mile Island’s new steam generator tubes could fail
Three Mile Island’s new steam generator tubes could fail
 
Report on Boilers at NTPC Ramagunadam
Report on  Boilers at NTPC RamagunadamReport on  Boilers at NTPC Ramagunadam
Report on Boilers at NTPC Ramagunadam
 
1
11
1
 
1
11
1
 
BTL Steag Presentation for improving the reliability
BTL Steag Presentation for improving the reliabilityBTL Steag Presentation for improving the reliability
BTL Steag Presentation for improving the reliability
 
Circuit Breaker: Part 2
Circuit Breaker: Part 2Circuit Breaker: Part 2
Circuit Breaker: Part 2
 
Technical Properties of A Nuclear Power Plant
Technical Properties of A Nuclear Power PlantTechnical Properties of A Nuclear Power Plant
Technical Properties of A Nuclear Power Plant
 
Study and CFD Analysis on Different Test Plate Specimens with Different Nozzl...
Study and CFD Analysis on Different Test Plate Specimens with Different Nozzl...Study and CFD Analysis on Different Test Plate Specimens with Different Nozzl...
Study and CFD Analysis on Different Test Plate Specimens with Different Nozzl...
 
Michael Mapes Final Project Revised[1]
Michael Mapes Final Project Revised[1]Michael Mapes Final Project Revised[1]
Michael Mapes Final Project Revised[1]
 
Fluxtrol's "Best Practice for Design and Manufacturing of Heat Treating Induc...
Fluxtrol's "Best Practice for Design and Manufacturing of Heat Treating Induc...Fluxtrol's "Best Practice for Design and Manufacturing of Heat Treating Induc...
Fluxtrol's "Best Practice for Design and Manufacturing of Heat Treating Induc...
 
Nuclear Power plants
Nuclear Power plantsNuclear Power plants
Nuclear Power plants
 
Faults in xray tube by Sandesh magar
Faults in xray tube by Sandesh magarFaults in xray tube by Sandesh magar
Faults in xray tube by Sandesh magar
 
Condenser in thermal power plants
Condenser in thermal power plantsCondenser in thermal power plants
Condenser in thermal power plants
 
Increasing Inductor Lifetime by Predicting Coil Copper Temperatures Paper
Increasing Inductor Lifetime by Predicting Coil Copper Temperatures PaperIncreasing Inductor Lifetime by Predicting Coil Copper Temperatures Paper
Increasing Inductor Lifetime by Predicting Coil Copper Temperatures Paper
 
Nuclear Reactors
Nuclear  ReactorsNuclear  Reactors
Nuclear Reactors
 
genographi gg12.pdf
genographi gg12.pdfgenographi gg12.pdf
genographi gg12.pdf
 
Nuclear Reactors
Nuclear  ReactorsNuclear  Reactors
Nuclear Reactors
 
Presentation Topic:- Nuclear Reactor
Presentation Topic:- Nuclear ReactorPresentation Topic:- Nuclear Reactor
Presentation Topic:- Nuclear Reactor
 
Remaining life assessment of refinery furnace tubes using finite element method
Remaining life assessment of refinery furnace tubes using finite element methodRemaining life assessment of refinery furnace tubes using finite element method
Remaining life assessment of refinery furnace tubes using finite element method
 
CONVECTIVE HEAT TRANSFER ANALYSIS IN A HELICAL COIL
CONVECTIVE HEAT TRANSFER ANALYSIS IN A HELICAL COILCONVECTIVE HEAT TRANSFER ANALYSIS IN A HELICAL COIL
CONVECTIVE HEAT TRANSFER ANALYSIS IN A HELICAL COIL
 

Más de Scott Portzline

Más de Scott Portzline (6)

Peach bottom relicensing sept 12 2019
Peach bottom relicensing sept 12 2019Peach bottom relicensing sept 12 2019
Peach bottom relicensing sept 12 2019
 
NRC efforts to improve rulemaking tracking and reporting
NRC efforts to improve rulemaking tracking and reportingNRC efforts to improve rulemaking tracking and reporting
NRC efforts to improve rulemaking tracking and reporting
 
Bakken oil trains 2
Bakken oil trains 2Bakken oil trains 2
Bakken oil trains 2
 
35th anniversary of the Three Mile Island accident
35th anniversary of the Three Mile Island accident35th anniversary of the Three Mile Island accident
35th anniversary of the Three Mile Island accident
 
Probability Studies of Nuclear Accidents are Flawed - here's why.
Probability Studies of Nuclear Accidents are Flawed - here's why.Probability Studies of Nuclear Accidents are Flawed - here's why.
Probability Studies of Nuclear Accidents are Flawed - here's why.
 
Soarca 2 22-12 post
Soarca 2 22-12 postSoarca 2 22-12 post
Soarca 2 22-12 post
 

Último

Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Sérgio Sacani
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
PirithiRaju
 
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdfPests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
PirithiRaju
 
Conjugation, transduction and transformation
Conjugation, transduction and transformationConjugation, transduction and transformation
Conjugation, transduction and transformation
Areesha Ahmad
 

Último (20)

Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune WaterworldsBiogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
Biogenic Sulfur Gases as Biosignatures on Temperate Sub-Neptune Waterworlds
 
GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)GBSN - Biochemistry (Unit 1)
GBSN - Biochemistry (Unit 1)
 
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdfPests of cotton_Sucking_Pests_Dr.UPR.pdf
Pests of cotton_Sucking_Pests_Dr.UPR.pdf
 
Pulmonary drug delivery system M.pharm -2nd sem P'ceutics
Pulmonary drug delivery system M.pharm -2nd sem P'ceuticsPulmonary drug delivery system M.pharm -2nd sem P'ceutics
Pulmonary drug delivery system M.pharm -2nd sem P'ceutics
 
High Profile 🔝 8250077686 📞 Call Girls Service in GTB Nagar🍑
High Profile 🔝 8250077686 📞 Call Girls Service in GTB Nagar🍑High Profile 🔝 8250077686 📞 Call Girls Service in GTB Nagar🍑
High Profile 🔝 8250077686 📞 Call Girls Service in GTB Nagar🍑
 
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 60009654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
9654467111 Call Girls In Raj Nagar Delhi Short 1500 Night 6000
 
9999266834 Call Girls In Noida Sector 22 (Delhi) Call Girl Service
9999266834 Call Girls In Noida Sector 22 (Delhi) Call Girl Service9999266834 Call Girls In Noida Sector 22 (Delhi) Call Girl Service
9999266834 Call Girls In Noida Sector 22 (Delhi) Call Girl Service
 
Forensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdfForensic Biology & Its biological significance.pdf
Forensic Biology & Its biological significance.pdf
 
chemical bonding Essentials of Physical Chemistry2.pdf
chemical bonding Essentials of Physical Chemistry2.pdfchemical bonding Essentials of Physical Chemistry2.pdf
chemical bonding Essentials of Physical Chemistry2.pdf
 
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdfPests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
Pests of cotton_Borer_Pests_Binomics_Dr.UPR.pdf
 
Introduction to Viruses
Introduction to VirusesIntroduction to Viruses
Introduction to Viruses
 
Locating and isolating a gene, FISH, GISH, Chromosome walking and jumping, te...
Locating and isolating a gene, FISH, GISH, Chromosome walking and jumping, te...Locating and isolating a gene, FISH, GISH, Chromosome walking and jumping, te...
Locating and isolating a gene, FISH, GISH, Chromosome walking and jumping, te...
 
Call Girls Ahmedabad +917728919243 call me Independent Escort Service
Call Girls Ahmedabad +917728919243 call me Independent Escort ServiceCall Girls Ahmedabad +917728919243 call me Independent Escort Service
Call Girls Ahmedabad +917728919243 call me Independent Escort Service
 
COST ESTIMATION FOR A RESEARCH PROJECT.pptx
COST ESTIMATION FOR A RESEARCH PROJECT.pptxCOST ESTIMATION FOR A RESEARCH PROJECT.pptx
COST ESTIMATION FOR A RESEARCH PROJECT.pptx
 
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
High Class Escorts in Hyderabad ₹7.5k Pick Up & Drop With Cash Payment 969456...
 
300003-World Science Day For Peace And Development.pptx
300003-World Science Day For Peace And Development.pptx300003-World Science Day For Peace And Development.pptx
300003-World Science Day For Peace And Development.pptx
 
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptxPSYCHOSOCIAL NEEDS. in nursing II sem pptx
PSYCHOSOCIAL NEEDS. in nursing II sem pptx
 
GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)GBSN - Microbiology (Unit 2)
GBSN - Microbiology (Unit 2)
 
Conjugation, transduction and transformation
Conjugation, transduction and transformationConjugation, transduction and transformation
Conjugation, transduction and transformation
 
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts ServiceJustdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
Justdial Call Girls In Indirapuram, Ghaziabad, 8800357707 Escorts Service
 

Three Mile Island Nuclear Plant steam generator safety is suspect

  • 1. Three Mile Island’s Steam Generator Safety Is Suspect During Reactor Transient Conditions TMI Alert Petitions the Nuclear Regulatory Commission to Take Enforcement Action March 11, 2019 Steam Generator Contact: Scott D. Portzline sdportzline1@verizon.net
  • 2. • There is a risky and dangerous unanalyzed safety condition involving the steam generators. • The steam generators could fail and stop removing heat from the reactor. • The problematic behavior is not predictable by standard engineering analyses. • Excessive fluttering of the steam tubes could occur when the reactor systems are challenged. • The steam generators could self-destruct. • Result in a "containment bypass accident." • A large amount of radiation is released without any time for an evacuation. TMI Unit #1
  • 3. “Consequential steam generator tube ruptures are potentially risk-significant events because thermally induced SG tube failures caused by hot gases from a damaged reactor core can result in a containment bypass event and a large release of fission products to the environment.” source: Nuclear Regulatory Commission NUREG-2195, May 2018
  • 4. Video: Fluttering of the Steam Tubes
  • 6. Each Steam Generator is 72 feet tall and packed with 15,597 vertically oriented Steam Tubes which are 56 feet in length. A section of Steam Tubes Tube Support Plate Tube Support Plate 3to4feet
  • 7. Top view from exelon Top view SG “B” 15,597 Steam Tubes 183 are damaged by tube-to-tube wear
  • 8. Top view The walls of the steam tubes are 2/3rds the thickness of a dime. Steam Tube The walls of the steam tubes are 2/3rds the thickness of a dime.
  • 9. Think of a steam generator as a heat exchanger. The steam tubes (in red) conveying the reactor coolant are separated by gaps through which a separate supply of water is pumped in an upward direction. This water is used to create steam. This is how the heat is exchanged from the reactor coolant to the water used for the steam. Side view Top view Steam generators are the primary method of cooling a reactor and as such are a very important safety component.
  • 10. Video: Turbulence Is Causing The Fluttering
  • 11. Feedback Mechanism “The more you have motion [of the steam tubes], the more you have hydraulic excitation. The more you have hydraulic excitation, the more you've got motion.” Principal Research Engineer Atomic Energy of Canada source: Nuclear Regulatory Commission briefing transcript, Feb. 7, 2013
  • 12. Not Reviewed by the NRC source: Nuclear Regulatory Commission briefing transcript, Feb. 7, 2013 “For the steam generators, the thermal hydraulic conditions on the secondary side are not something that’s within our standard review plan.” Nuclear Reactor Regulations Reactor Systems Branch Chief
  • 13. TMI Alert contends that an analysis must be performed on the steam tubes for transient conditions based on direct input from the plant system thermal hydraulic analyses. Because TMI Unit #1 has already experienced unexpected steam tube damage as the result of fluttering, there appears to be a significant increased risk of an accident and a significant increase in the consequences of such an accident.
  • 14. The NRC considers a steam tube rupture an “accident” because it leaks reactor coolant into the steam supply.
  • 15. Steam tubes are an integral part of the reactor coolant pressure boundary and as such, are relied upon to maintain the reactor system's pressure and coolant inventory.
  • 16. The rupture of multiple steam tubes results in a large break loss-of-coolant accident. Steam tube ruptures can be the cause of a severe accident and radiological release.
  • 17. • “These [spontaneous] ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. • A continuing issue has been - exactly what constitutes an appropriate and timely inspection and which degraded tubes are still fit for service. • The most widely used inspection equipment is not able to detect and size all the degradation of concern.” source: Idaho National Laboratory NUREG-6365, April 1996
  • 18. The rupture of the steam tubes “can result in a containment bypass event and a large release of fission products to the environment.” NUREG-2195 This scenario is called a “containment bypass accident” because a pathway is created for radiation to escape out of the containment building and into the environment. Reactor coolant jetting from a ruptured steam tube.
  • 20. Three Mile Island Unit #1 Tube-to-Tube Wear bowing + fluttering Steam Generator Image source: Nuclear Regulatory Commission briefing 2/7/2013 - Steam Generator Tube Degradation A total of 257 steam tubes showed signs of tube-to-tube wear. A few were approximately 20% through the tube wall.
  • 23. The damage done to TMI’s steam tubes was caused by mistakes made by AREVA, the French manufacturer of the steam generators. • DESIGN FLAW • MANUFACTURING DEFECT • OVERLY AGGRESSIVE DESIGN Steam Generator
  • 24. 1. Design Flaw thermal expansion rates Steam Generator When operating, the steam generator shell stays cooler than expected. The steam tubes expand at a greater rate than the shell. The result is that the tubes experience higher compressive loads from end-to-end than planned. This results in bowing of the tubes. Root Cause
  • 25.
  • 26. “During a transient condition the thermal expansion can be significant.” Steam Generator Integrity Assessment Guidelines Revision 3, Electric Power Research Institute
  • 27. 2. Manufacturing Defect Steam Generator The steam generators were not constructed as designed. Specifically, the preload tensile value of the steam tubes was less than called for by the design specification. The result is the steam tubes experience a higher compressive load than planned. Root Cause
  • 28.
  • 29. 3. Overly Aggressive Design Steam Generator • The margin to steam tube bowing was not conservative. • The steam tube walls are thinner than the previous design. • The steam tubes are smaller in diameter and packed together tighter than in previous designs. The gap between the tubes is only 1/8 inch when the reactor is operating at normal temperatures. Root Cause
  • 30.
  • 31. Steam Generator • The margin to steam tube bowing was not conservative. • The steam tube walls are thinner than the previous design. • The steam tubes are smaller in diameter and packed together tighter than in previous designs. The gap between the tubes is only 1/8 inch when the reactor is operating at normal temperatures. 3. Overly Aggressive Design Root Cause
  • 32. Steam Generator • The margin to steam tube bowing was not conservative. • The steam tube walls are thinner than the previous design. • The steam tubes are smaller in diameter and packed together tighter than in previous designs. The gap between the tubes is only 1/8 inch when the reactor is operating at normal temperatures. Therefore, these three specifications, produced by intentional design, make any tube-to-tube wear of even greater concern regarding steam tube ruptures. Root Cause 3. Overly Aggressive Design
  • 33. Alloy 690 • The new metal Alloy 690 used to manufacture the steam tubes is less resistant to stress corrosion cracking, but it frets, pits and wears faster that the metal used in previous designs (Alloy 600). • As time goes by there is a greater risk of tube cracking and rupture. “Through these experiments, it is found that the fretting fatigue strength decreased about 43% compared to the plain fatigue strength…. oblique micro-cracks are initiated at an earlier stage.” Fretting wear source: A Study on Fretting Behavior in Room Temperature for Inconel Alloy 690
  • 34. Under reactor transient conditions, the steam generators could self-destruct due to fluttering steam tubes. Steam Genrator At TMI Unit #1 steam tube flutter is created by the turbulent and chaotic flow of the secondary system water between the tubes (thermal hydraulic conditions). Under higher temperatures, the energy of the flutter could impart severe damage to many steam tubes, including ones that were not effected during normal operating temperatures. This represents a hidden consequence of the new design.
  • 35. Under reactor transient conditions, the steam generators could self-destruct due to fluttering steam tubes. Steam Genrator At TMI Unit #1 steam tube flutter is created by the turbulent and chaotic flow of the secondary system water between the tubes (thermal hydraulic conditions). Under higher temperatures, the energy of the flutter could impart severe damage to many steam tubes, including ones that were not effected during normal operating temperatures. This represents a hidden consequence of the new design.
  • 36. • Greater number of tubes bowing • Greater severity of the bowing • Changes in geometry of the SG due to narrowing of the tube gaps • Greater velocity of water between the tubes • Greater amount of energy of the flutter (lateral accelerations) • Flutter could become more chaotic • The effects of harmonic resonance disturbance • Additional damage to the steam tubes at the Tube Support Plates TMI Alert expects these conditions and behaviors to be analyzed under reactor transient conditions:
  • 37. • Greater number of tubes bowing • Greater severity of the bowing • Changes in geometry of the SG due to narrowing of the tube gaps • Greater velocity of water between the tubes • Greater amount of energy of the flutter (lateral accelerations) • Flutter could become more chaotic • The effects of harmonic resonance disturbance • Additional damage to the steam tubes at the Tube Support Plates TMI Alert expects these conditions and behaviors to be analyzed under reactor transient conditions: Tube Support Plate
  • 38. Design changes went too far! TMI Alert asserts that the design changes of the replacement steam generators, primarily the geometry of the internal components, • the steam tube size • reduced gap between the steam tubes constitutes a violation of the NRC regulation on changes. • regulation §50.59 in 10 CFR "Changes, tests and experiments."
  • 39. San Onofre Defective Steam Generators • At the San Onofre Nuclear Generating Station, tube-to-tube wear caused the degradation of their replacement steam generators. • A design error resulted in the actual steam generators having more severe thermal-hydraulic conditions than expected, which contributed, along with other factors, to the rapid steam tube wall degradation. • The steam tube walls at TMI are 20% thinner than at San Onofre.
  • 40. Incremental changes Nuclear plants are allowed to make small changes to their reactor components and safety systems without amending their license. However, a series of small changes in one component can add up to a risky and dangerous defect. As the conservative margin for safety and reliability is decreased in the pursuit of efficiency, the line delineating safe from unsafe designs grows ever closer. At some point, safety systems will not be able to perform their functions under stressful loads or conditions. Some of these defects can be hidden from detection under normal testing and analysis; even for the analytical methods approved by the industry. SAFE UNSAFE