SHYAM CABLE INDUSTRIES
All Types Of Cables Manufacturer Company
Engineering Customized Power Solutions
WELCOME TO

OUR COMPANY
Chapter

Page No.

INTRODUCTION
PRODUCT RANGE

2

LIST OF GOVERNMENT CLIENTS

3

LIST OF OTHER REPUTED CLIENTS

4

LIST OF MACHINERY

5

LIST OF TESTING EQUIPMENTS

6

QUALITY CONTROL

7

CURRENT RATING

8

PROCESS FLOW CHART (PVC CABLES)

9

QUALITY ASSURANCE PLAN (PVC CABLES)

10

CONSTRUCTION OF POWER CABLES

14

PROCESS FLOW CHART (RUBBER CABLES)

23

QUALITY ASSURANCE PLAN (RUBBER CABLES)

24

TECHNICAL OF ELASTOMERIC CABLES

26

TECHNICAL OF WELDING CABLES

28

PROPERTIES OF RAW MATERIAL USED

33

TELEPHONE CABLES

40

LIST OF REGISTRATION CERTIFICATE & PERFORMANCE CERTIFICATES

42

LIST OF PURCHASE ORDERS

1

1

52
SALIENT FEATURES
1.
Well equipped and most modern laboratory having ISO-9001 and ISI carrying out
extensive tests from raw materials to final products at various stages.
2.

Cables manufacturing conforming to various National and International specifications
having four “BIS” License: 9968/Pt-I/1988, 1554/Pt-1/1988, 9857/90 & 694/90.

3.

Approval accorded by a number of Organisations and Inspection agencies of International
repute like IFFCO, BHEL, NLC, RSP, BSP, SAIL, ONGC, NTPC, DGS&D, Air Hqs., DGQA
(Naval) LGT, MECON, PDIL etc.

4.

Specialisation in Elastometric / Flexible Cables (Butyl/EPR, PCP /CSP and Silicon Rubber
Cables)

5.

40 successful years of regular supply to numerous Government Departments / Public /
Private Sector Industrial Enterprises.

6.

80% of Production ongoing to Government Department and reputed public Sector
Undertaking all over the country.

CLIENTELE
Our more than 40 years of journey towards service with excellence has given us numerous all over
India in all the sectors of the India Economy, 80% of them in government / Public Sector. Today
hundreds of industrial enterprises rely on Shyam Cable in the key sectors like Steel plants, Power
Projects, Aeronautics, Ordnance factories, Railways, Fertilizer Plants, Atomic Energy, Air Force,
Petroleum, Navy, Shipyards, Mines, Power Stations, Oil & Natural Gas, Port Trusts, Coalfields,
Heavy Engineering, Telecommunication. Electrical and Electronics, Wind Energy and so on.

2
PRODUCTS
S.No. Type of Cables
upto)

Specification

Size (Including &
No of cores x Area in Sq.mm

1.

Elastomeric Cables
(VIR/TRS, EPR, PCP/CSP &
Silicon Rubber Insulated Cables)

2.

Power & Controls Cables
(Armoured /Unarmoured PVC
Insulated & Sheathed)

3.

Welding Cables
(Copper & Aluminium)

5.

PVC Wires/Cables
Lighting Cables
Screened Cables
Instrumentation Cables
Compensating Cables

“

1 x 1000
3.5 x 630
61 x 2.5

IS: 1554/88/Pt-1
ISI Marked”

1 x 1000
3.5 x 630
61 x 2.5

IS: 9968/88/Pt-1 & Pt-II
Upto 6.6/11 KV

“

Trailing Cables

4.

IS: 9968/88/Pt-1
“ISI Marked”

1 x 1000
3.5 x 630
61 x 2.5

IS: 9857/90
ISI Marked”

All Sizes

IS: 694/90
“ISI Marked”

All Sizes

IS: 5608
IS: 8784

6.

IS: 1554/88

All Sizes

7.

Telephone Cables
(Armoured /Unarmoured)

ITD-3003
G/WIR-06/02

100 Pairs

8.

Submersible
Flat Cables

IS: 694/90
IS: 9968/88/Pt-1

61 x 2.5
4 x 400

9.

XLPE Cables
(Armoured/ Unarmoured XLPE
Insulated & Sheathed Cables)

IS: 7098

1 x 1000
3.5 x 630
61 x 2.5

10.

3

FRLS Cables ASTM/D-2843

Kynar / HMWPE

All Sizes
LIST OF

GOVERNMENT CLIENTS
S A I L / BHILAI STEEL PLANT

BEML

S A I L / BOKARO STEEL PLANT

NTPC

S A I L / ROURKELA STEEL PLANT

ONGC

S A I L / DURGAPUR STEEL PLANT

NALC O

NEYVELI LIGNITE CORP. LTD.

NHPC

B H E L (HARIDWAR & TIRUCHIRAPALLI)

GAIL (INDIA) LIMIITED

DAMODER VALLEY CORPORATION

TRIVENI STRUCTURALS LTD.

R C F (KAPURTHALA)

NATIONAL MINERALS DEVELOPMENT CORP. LTD.

MAZGOAN DOCK LTD.

VISHAKHAPATNAM PORT TRUST

NATIONAL FERTILIZER LIMITED

I F F C O Limited

NUMALIGARH REFINERY LIMITED

URANIUM CORPORATION INDIA LIMITED

THERI HYDRO DEVP. CORP. LTD.

BONGAIGAON REFINERY & PETROCHEMICALS LTD.

CONTAINER CORP. OF IND. LTD.

PANIPAT THERMAL POWER STATION

N.E.E.P.C.O. LIMITED

COAST GUARD

ORDNANCE FACTORIES

NAVAL (MUMBAI, KOCHI, GOA)

HINDUSTAN STEEL WORKS CONS. LTD.

BHARAT HEAVY PLATES & VESSELS LTD.

INDIA AIR FORCE

CHENNAI PORT TRUST

SATLUJ JAL VIDYUT NIGAM LTD.

VISAKHAPATNAM STEEL PLANT

NORTHERN RAILWAYS

MEC0N LTD.

P.D.I.L

INDIAN OIL CORP. LTD.

4
LIST OF OTHER

REPUTED CLIENTS
RELIANCE INDUSTRIES LIMITED

ENERCON

RELIANCE PETROLEUM LIMITED

GUJARAT AMBUJA CEMENT

ELECON ENGINEERING CO. LTD.

BHUSHAN STEEL LTD.

FENNER INDIA LTD.

JINDAL STAINLESS LTD.

ISGEC

JINDAL PIPE LTD.

DC M SHRIRAM (DAURALA)

SIEMENS LIMITED

BALCO

L&T LTD.

A.B.B. LTD.

ADANI GROUP

ESSAR GROUP

JINDAL STEEL & POWER

PRAKASH INDUSTRIES LIMITED
SUZLON ENERGY LTD.
MUKAND LIMITED
BEEKAY ENGG. CORPORATION
RATHI SUPER STEEL LIMITED
BAJAJ HINDUSTAN LTD.
MONNET ISPAT & ENERGY LTD.
SIMPLEX ENGG. & FOUNDRY WORKS (P) LTD.

.

5

.
LIST OF

MACHINERY
PVC Extruders (150 mm)

Kneader

PVC Extruders (100 mm)

PVC Mixtures

PVC Extruders (75 mm)

Rubber Mixing Mills

PVC Extruders (40 mm)

M.S. Vulcanisers Complete with

Rubber Extruders (100 mm)
Rubber Extruders (75 mm)
Rubber Extruders (40 mm)
Tray and stand.
Bale Cutting Machine
Wire Stranding & Trapping Machines
Taping Heads
High Speed Bunching Machine
Armouring Machines
Braiding Machines of various sizes
Core Printing Machine
Sequential length marking machine
M. S. Trolley
Laying Machines
Spooling Machines
High Speed Bunching
Welding Machine
Oil Fired Boiler

6
LIST OF

TESTING EQUIPMENTS
AC High Voltage Tester 10 KV
AC High Voltage Tester 30 KV

Mandral for Bending Test

Double Kelvin Bridge

Dombell Die with Stand

Million Meghohms Meter

Tear Resistance Attachment

Hot Deformation Test Apparatus

Air & Oxygen Bomb Apparatus

Volumetric Test Apparatus

Oxygen Cylinder

Annealing Test Apparatus

Meggar

Hot Water Bath

Spark Tester

DC High Voltage

Air Compressor

Hydraulic Press

Tensile Testing Machine

Capacitance Meter

Travelling Microscope

Flamability Test Apparatus

Flame Resistance Test Apparatus

Standard Resistance Box

Hot set Test Apparatus

Micrometer

Humidity Conditioning Chamber

Digital Milliohm Meter

Ozone Test Apparatus

Air Hot Oven

Cold Band Test Apparatus

Fault Locator

Smoke Density

Physical Balance

Oxygen Index

Multimeter

Halogen Acid Gas Generation

Ageing Oven

Swedish Chimney

Ageing Air Oven

7

Single Pan Electrical Balance

Ladder Test
QUALITY CONTROL
QUALITY CONTROL
1.
2.
3.

Raw Material Control.
Process Control & Continuous on-line testing.
Product Control.

Shyam Cables maintains very high standards of product quality through a very strict and efficient
quality control system mainly.
RAW MATERIAL CONTROL
All raw materials under go rigorous testing for the conformity and stability in the
manufacturing process. A highly qualified and experienced group of Chemists ensure that
no sub-standard material is used in processing of cables.
PROCESS CONTROL
Process is controlled and checked by a team of experts and any deviations from standard
process in immediately checked and corrective action is taken.
PRODUCT CONTROL
100% testing and checking is done for cables. So that they are capable of giving
satisfactory services in actual use. Our engineers ensure the cable conform to the
standards is specified and results are well within relevant values.
Elastometric Insulated Cables for working voltage upto and insulating 1100 Volts as per IS9968 - Part - I/1988 “ISI Marked” and upto as per IS:9968 Part - II/81.
The elastometric insulated cables for fixed wiring, flexible cables and flexible cords for
electric power and lighting for operation at voltage upto an including 6.6 K.V. is
manufactured as per the requirements specified in IS: 9968 (Part-II) 1981.
The type of cables covered under this standard are as follows:1)
For Fixed Wiring.
a)
Braided and Compounded/Varnished.
b)
Elastomeric sheathed (general purpose)
c)
Elastomeric with earth community conductor (ECC)
2)
For Fixed Wiring.
a)
Braided and Varnished.
b)
Elastomeric sheathed (Heavy Duty)
3)
For Flexible Cords.
a)
Braided.
b)
Elastomeric sheathed (general purpose)
c)
Unlinkable flexible cords.

8
CURRENT RATINGS
The current ratings in table 1 & 2 based on the normal conditions of installation as described below :
0
1. Maximum condr. Temperature
70 C
5. Thermal resistivity of soil
0
2. Ambient air temperature
40 C
6. Thermal resistivity of cable
0
3. Ground temperature
30 C
7. Max. short-circuit conductor temp.
4. Depth of laying (for cable
8. Max. Ambient Air Temperature
laid directly in ground )
75 cm (1.1 KV)

0

150 C cm/watt
0
650 C cm/watt
0
160 C
0
55 C

Installation method and rating factors are given in tables 1 to 6.

Table -1
Rating for variations in ground temperature for cables laid directly in ground and in ducts
0

Ground temperature C

15

20

25

30

35

40

45

50

55

1.17

Rating factor

1.12

1.06

1.0

0.94

0.87

0.79

0.70

0.80

Table -2
Rating factors for variation in amblent air temperature
0

Air temperature C

25

35

40

45

50

55

1.25

Rating factor

30
1.16

1.09

1.00

0.90

0.80

0.69

Table- 3
Rating factors of groups of twin and multicore cables laid directly in ground in horizontal formation
No. of cables

Rating factor for axial spacing
Touching

15 cm

30 cm

45 cm

60 cm

2 cables

0.78

0.81

0.85

0.88

0.90

3 cables

0.68

0.71

0.77

0.81

0.83

4 cables

0.61

0.65

0.72

0.76

0.79

6 cables

0.53

0.58

0.66

0.71

0.78

8 cables

0.48

0.54

0.62

0.67

0.72

Table -4
Rating factors of groups of twin and multicore cables laid directly in ground in tier formation
Rating factor for axial spacing

No. of cables
Touching

15 cm

30 cm

45 cm

60 cm

4 cables

0.60

0.67

0.73

0.76

0.78

6 cables

0.51

0.57

0.63

0.67

0.69

8 cables

0.45

0.51

0.57

0.59

0.61

Table -5
Rating factors for variation in depth of laying in ground
Depth of laying
Rating factor upto 25 sq.
mm.

75

90

105

120

150

150& above

1.00

0.99

0.98

0.97

0.96

0.95

Table 6
Group-rating factors for cables installed in ground, separated by more than 7 cms.
No of cables

2

3

4

5

6

Single core D.C cables & multicore power cables

1.0

0.90

0.80

0.75

0.70

0.65

Single core A.C. cables

9

1

1.0`

0.80

0.75

0.70

0.65

0.60
PROCESS FLOW

CHART FOR PVC CABLES

10
QUALITY ASSURACE

CHART FOR PVC CABLES

11
QUALITY ASSURACE

CHART FOR PVC CABLES

12
QUALITY ASSURACE

CHART FOR PVC CABLES

13
QUALITY ASSURACE

CHART FOR PVC CABLES

14
POWER & CONTROL CABLE AS PER IS-1554 (PART-I) 1988
1.1 K.V Grade, Copper/Aluiminum Conductor, PVC/HR PVC Insulated
core laid up and PVC Inner Sheath, G.I. Steel Wire/Strip armoured
and Overall PVC/HR PVC/FRLS PVC sheathed Cable “ISI MARKED”
Material :
Copper conductors are of annealed high conductivity copper wires
IS:8130/1984.
Aluminium conductors are of aluminium wire complying to IS-8130-1984.

complying to

Insulation :
It is of PVC compound conforming to the requirements of Type - A,B,C, of IS-5831-84
Inner Sheath : (Common Covering)
a)
Vulcanised or unvulcanised rubber
b)
Thermoplastic material
c)
Proofed or plastic tape
Armoured :
a)
Galvanised round steel wire
b)
Galvanised steel strip
Outer Sheath :
The outer sheath is of PVC compund conforming to the requirements of Type ST-1, ST-2
of IS-5831-1970
Conductor :
(Nominal Cross Sectional/Area in mm )
2

Copper
1.5
2.5 to 6
10 and above

Aluminium

Solid/Stranded

1.5
2.5 to 10
6 and aboveStranded

Solid
Solid
Stranded

THE CABLES AMPACITY
Standard Conditions of installation for which the current carrying capacity
is given in the ensuing tables are :
Conductor temperature
Thermal resistivity of soil
Thermal resistivity of PVC
Ambient temperature
Ground temperature
Depth of laying cable

15

:
:
:
:
:
:

70 C Maximum
150 C cm/w
650 C cm/w
40 C
30 C
75 cm in the ground
0

0

0

0

0
UNARMOURED CONTROL CABLE IS : 1554 (Pt - I ) - 1988
A p p ro x .
N et.
W eig h t
of
C a b les
K g /k m

S ta n d a rd
D eliv ery
L en g th
in M trs.

1 1 .8

185

1000

23

20

1 2 .3

190

1000

21

17

1 .8

1 3 .2

225

1000

21

17

0 .3

1 .8

1 4 .1

260

1000

16

14

0 .8

0 .3

1 .8

1 5 .1

295

1000

15

13

0 .8

0 .3

1 .8

1 5 .1

315

1000

14

13

1 0 x 1 .5

0 .8

0 .3

1 .8

1 8 .4

425

1000

13

11

1 2 x 1 .5

0 .8

0 .3

1 .8

1 8 .9

480

1000

12

10

1 4 x 1 .5

0 .8

0 .3

1 .8

1 9 .8

535

1000

11

10

1 6 x 1 .5

0 .8

0 .3

1 .8

2 0 .7

595

1000

11

9

1 9 x 1 .5

0 .8

0 .3

2 .0

2 2 .5

720

1000

10

9

2 4 x 1 .5

0 .8

0 .3

2 .0

2 5 .8

880

1000

9

8

2 7 x 1 .5

0 .8

0 .3

2 .0

2 6 .3

960

1000

9

8

3 0 x 1 .5

0 .8

0 .3

2 .0

2 7 .2

1040

1000

9

7

3 7 x 1 .5

0 .8

0 .3

2 .0

2 9 .1

1230

1000

8

7

2 x 2. 5

0 .9

0 .3

1 .8

1 3 .0

230

1000

32

27

3 x 2. 5

0 .9

0 .3

1 .8

1 3 .6

240

1000

27

24

4 x 2. 5

0 .9

0 .3

1 .8

1 4 .6

290

1000

27

24

5 x 2. 5

0 .9

0 .3

1 .8

1 5 .7

335

1000

23

19

6 x 2. 5

0 .9

0 .3

1 .8

1 6 .9

385

1000

21

18

7 x 2. 5

0 .9

0 .3

1 .8

1 6 .9

420

1000

20

17

10 x 2. 5

0 .9

0 .3

1 .8

2 0 .8

570

1000

18

15

12 x 2. 5

0 .9

0 .3

2 .0

2 2 .2

690

1000

17

14

14 x 2. 5

0 .9

0 .3

2 .0

2 3 .2

775

1000

16

13

16 x 2. 5

0 .9

0 .3

2 .0

2 4 .3

860

1000

15

13

19 x 2. 5

0 .9

0 .3

2 .0

2 5 .5

985

1000

14

12

24 x 2. 5

0 .9

0 .3

2 .0

2 9 .4

1215

1000

13

11

27 x 2. 5

0 .9

0 .3

2 .0

3 0 .0

1330

1000

12

10

30 x 2. 5

0 .9

0 .3

2 .0

3 1 .0

1450

1000

12

10

37 x 2. 5

0 .9

0 .3

2 .2

3 4 .1

1790

1000

11

9

N o. of
C ro res
& C ro ss
S ectio n a l
A rea N O
x m m 2.

T h ick n ess
of PV C
in su ta io n
(N o m .)

T h ick n ess
of PV C
In n ersh ea th
(M in )

T h ik n ess o f
PV C
o u tersh ea th
(N o m .)

mm

mm

mm

2 x 1 .5

0 .8

0 .3

1 .8

3 x 1 .5

0 .8

0 .3

1 .8

4 x 1 .5

0 .8

0 .3

5 x 1 .5

0 .8

6 x 1 .5
7 x 1 .5

A p p ro x .
O .D .

mm

C u rren t R a tin g
D irect in
In
G ro u u n d A ir/D u ct
A m p s.
A m p s.

Construction
1. Solid/ Stranded annealed copper conductor & Tinned / Bare
2. General Purpose /HR PVC insulation
3. Cores laid up (filled if needed )
4. FRLS / General Purpose PVC inner Sheath
5. FRLS / General Purpose PVC Outer sheath
Max Conductor D.C Resistance at 20 Deg C – Conductor Size:
1.5 sq mm -12.1 Ohm /km (Bare, 12.2 Q/km (Tinned)
2.5 sq mm -7.41 Ohm /km (Bare, 7.56 Q/km (Tinned)
*Dimensions specified are with stranded conductor

16
1 CORE ALUMINIUM PVC ARMOURED POWER CABLES
Type

No. of
cores
&Cross
Section
al Area

Min
no. of
Wires

Thickness
of PVC
insulation
(nom)

Nominal
Dimension
s of
Armour
Wire (mm)

Mm

Min
Thickness
of PVC
Outer
Sheath

Overall
Deamte
r
(Approx
)

(mm)

Approx
Net Wt
of cable

Max.D.
C
Resista
nce at
70

Max AC
Resista
nce at
70

Ohms/k
m
8.8900

0.158

0.47

(Kg/Km)

Approx
Reactance
at 50Hz

Approx.
Capacit
ance

Km

160

Ohms
/km
7.4100

Km

Ayway

1

1.30

1.40

1.24

Ayway

1Cx6

1

1.30

1.40

1.24

12

180

4.6100

5.5300

0.148

0.56

Ayway

1Cx10

1

1.30

1.40

1.24

13

210

3.0800

3.7000

0.138

0.67

Ayway

1Cx16

6

1.30

1.40

1.24

14

240

1.9100

2.2900

0.128

0.81

Ayway

1Cx25

6

1.50

1.40

1.24

15

310

1.2000

1.4400

0.120

0.87

Ayway

1Cx35

6

1.50

1.40

1.24

16

360

0.8680

1.0400

0.114

1.00

Ayway

1Cx50

6

1.70

1.40

1.24

18

450

0.6410

0.7700

0.110

1.03

Ayway

1Cx70

12

1.70

1.40

1.40

20

560

0.4430

0.5300

0.103

1.21

Ayway

1Cx95

15

1.90

1.60

1.40

22

720

0.3200

0.3800

0.101

1.27

Ayway

1Cx120

15

1.90

1.60

1.40

24

830

0.2530

0.3000

0.096

1.42

Ayway

1Cx150

15

2.10

1.60

1.40

27

980

0.2060

0.2500

0.094

1.42

Ayway

1Cx185

30

2.30

1.60

1.40

28

1160

0.1640

0.2000

0.092

1.44

Ayway

1Cx240

30

2.50

1.60

1.56

31

1450

0.1250

0.1500

0.090

1.53

Ayway

1Cx300

30

2.70

2.00

1.56

35

1710

0.1000

0.1200

0.088

1.56

Ayway

1Cx400

53

3.00

2.00

1.56

39

2190

0.0778

0.0934

0.088

1.56

Ayway

1Cx500

53

3.40

2.00

1.72

40

2730

0.0605

0.0726

0.087

1.57

Ayway

1Cx630

53

3.90

2.00

1.88

48

3440

0.0469

0.0563

0.086

1.57

Ayway

1Cx800

53

3.90

2.00

1.88

52

4120

0.0367

0.0440

0.083

1.75

Ayway

17

1Cx4

(mm)
11

1Cx1000

53

3.90

2.50

2.04

57

5090

0.0291

0.0349

0.082

1.94
1 CORE ALUMINIUM PVC UNARMOURED POWER CABLES
Type

No. of
cores
&Cross
Sectional
Area

Min
no. of
Wires

Thickness
of insulation
(nom)

Nom.
Thickness
of Outer
Sheath

Overall
Diameter
(Appro)

Net Wt of
cable
(approx)

Max.D.C
Resistan
ce at
0
20 C

Max AC
Resistance
0
at 90 C

Approx
Reactanc
e at 50Hz

Approx.
Capacita
nce

Mm

(mm)

(mm)

(Kg/Km)

Ohms
/km

Ohms/km

Km

Km

Ayy

1CX4

1

1.00

1.80

8

100

7.4100

8.8900

0.137

0.58

Ayy

1CX6

1

1.00

1.80

9

110

4.6100

5.5300

0.127

0.68

Ayy

1CX10

1

1.00

1.80

10

130

3.0800

3.7000

0.118

0.83

Ayy

1CX16

6

1.00

1.80

11

160

1.9100

2.2900

0.110

1.01

Ayy

1CX25

6

1.20

1.80

12

220

1.2000

1.4400

0.105

1.05

Ayy

1CX35

6

1.20

1.80

13

260

0.8680

1.0400

0.100

0.22

Ayy

1CX50

6

1.40

1.80

15

330

0.6410

0.7700

0.098

1.22

Ayy

1CX70

12

1.40

1.80

17

410

0.4430

0.5300

0.091

0.43

Ayy

1CX95

15

1.60

1.80

19

530

0.3200

0.3800

0.088

1.47

Ayy

1CX120

15

1.60

2.00

21

640

0.2530

0.3000

0.086

1.62

Ayy

1CX150

15

1.80

2.00

23

770

0.2060

0.2500

0.085

1.62

Ayy

1CX185

30

2.00

2.00

25

920

0.1640

0.2000

0.084

1.62

Ayy

1CX240

30

2.20

2.00

28

1160

0.1250

0.1500

0.082

1.72

Ayy

1CX300

30

2.40

2.00

30

1390

0.1000

0.1200

0.080

1.74

Ayy

1CX400

53

2.60

2.20

35

1760

0.0778

0.0934

0.080

1.81

Ayy

1CX500

53

3.00

2.20

39

2200

0.0605

0.0726

0.079

1.76

Ayy

1CX630

53

3.40

2.40

44

2620

0.0469

0.0563

0.077

1.77

Ayy

1CX800

53

3.40

2.40

48

3430

0.0367

0.0440

0.077

1.98

Ayy

1CX1000

53

3.40

2.60

53

4180

0.0291

0.0349

0.076

2.20

18
2 CORE ALUMINIUM PVC ARMOURED POWER CABLES
Type

No. of
cross &
Cross
Sectional
Area

Min no.
of Wires

Thickne
ss of
PVC
insulati
on
(nom)
Mm

Min
Thic
knes
s of
PVC
Oute
r
She
ath(
mm)

Nominal
Dimension of
Armour
Strip Wire
(mm)

Min. Thickness OF
pvc outer
strength
Strip Wire
Armour Armour

Overall Diameter
(approx)
Strip Wire
Armour Armour

Appox Net Wt. of
cable
Strip wire
Armour

(mm)

Max.D.
C
Resista
nce at
20

Max
AC
Resist
ance
at 70

Approx
Reacta
nce at
50Hz

(mm)

Approx.
Capacit
ance

Km
Km
(Kg/Km)

Ohms
/km

Ohms
/km

Aywy

1

0.8

0.3

-

1.40

-

1.24

-

13.5

-

390

18.10

21.72

0.126

0.14

Aywy

2CX2.5

1

0.9

0.3

-

1.40

-

1.24

-

15.0

-

450

12.10

14.52

0.119

0.15

Aywy

2CX4

1

1.0

0.3

-

1.40

-

1.24

-

16.5

-

550

7.41

8.89

0.116

0.16

Aywy

2CX6

1

1.0

0.3

-

1.40

-

1.24

-

17.5

-

640

4.61

5.53

0.110

0.19

Aywy

2CX10

1

1.0

0.3

-

1.40

-

1.24

-

19.0

-

745

4.08

3.70

0.100

0.22

Aywy/
Ayfy

2CX16

6

1.0

0.3

4X0.8

1.60

1.40

1.40

20.5

22.5

565

830

1.91

2.29

0.097

0.29

Aywy/
Ayfy

2CX25

6

1.2

0.3

4X0.8

1.60

1.40

1.40

21.0

23.0

700

905

1.20

1.44

0.097

0.32

Aywy/
Ayfy

2CX35

6

1.2

0.3

4X0.8

1.60

1.40

1.40

22.5

24.0

810

1040

0.868

1.04

0.097

0.37

Aywy/
Ayfy

2CX50

6

1.4

0.3

4X0.8

1.60

1.40

1.56

25.0

27.0

1000

1290

0.641

0.77

0.094

0.37

Aywy/
Ayfy

2CX70

12

1.4

0.3

4X0.8

1.60

1.56

1.56

28.0

29.5

1230

1510

0.443

0.53

0.090

0.44

Aywy/
Ayfy

2CX95

15

1.6

0.4

4X0.8

2.00

1.56

1.56

31.5

34.0

1520

2060

0.320

0.38

0.090

0.44

Aywy/
Ayfy

2CX120

15

1.6

0.4

4X0.8

2.00

1.56

1.72

33.5

36.5

1765

2360

0.253

0.30

0.087

0.49

Aywy/
Ayfy

2CX150

15

1.8

0.4

4X0.8

2.00

1.72

1.72

37.0

39.5

2080

2700

0.206

0.25

0.087

0.49

Aywy/
Ayfy

2CX185

30

2.0

0.5

4X0.8

2.00

1.88

1.88

41.0

43.0

2500

3175

0.164

0.20

0.087

0.49

Aywy/
Ayfy

2CX240

30

2.2

0.5

4X0.8

2.50

2.04

2.04

45.5

49.0

3075

4230

0.125

0.15

0.087

0.50

Aywy/
Ayfy

2CX300

30

2.4

0.6

4X0.8

2.50

2.20

2.20

50.0

53.5

3760

4950

0.100

0.12

0.086

0.52

Aywy/
Ayfy

19

2CX1.5

2CX400

53

2.6

0.7

4X0.8

3.15

2.36

2.52

55.5

60.5

4560

6560

0.0778

0.09

0.086

0.53
3 CORE ALUMINIUM PVC ARMOURED POWER CABLES
Type

No. of
cores
&Cross
Section
al Area

Min
no. of
Wires

Thick
ness
of
PVC
insula
tion
(nom)
(mm)

Min
Thi
ckn
ess
of
PV
C
Out
er
She
ath(
mm
)

Nominal
Dimension of
Strip/Wire
Armour

Min. Thickness
OF pvc outer
strength
Strip/ Wire
Armour

Overall
Diameter
(approx)
Strip/Wire
Armour

Appox Net Wt.
of cable
Strip/wire
Armour

Max.
D.C
Resist
ance
at 20

Max
AC
Resi
stan
ce at
70

Approx
Reactan
ce at
50Hz

Approx
Capaci
tance

(mm)

(mm)

(mm)

(Kg/Km)

Ohms
/km

Ohm
s/km

Km

Km

Aywy

3Cx1.5

1

0.8

0.3

-

1.40

-

1.24

-

14.0

-

420

18.10

21.72

0.126

0.14

Aywy

3Cx2.5

1

0.9

0.3

-

1.40

-

1.24

-

15.0

-

500

12.10

14.52

0.119

0.15

Aywy

3Cx4

1

1.0

0.3

-

1.40

-

1.24

-

16.5

-

595

7.41

8.89

0.116

0.41

Aywy

3Cx6

1

1.0

0.3

-

1.40

-

1.24

-

17.5

-

685

4.61

5.53

0.110

0.47

Aywy

3Cx10

1

1.0

0.3

-

1.40

-

1.40

-

19.5

-

830

3.08

3.70

0.100

0.56

Aywy/
Ayfy

3Cx16

6

1.00

0.3

4x0.8

1.60

1.40

1.40

19.5

21.0

680

890

1.91

2.29

0.097

0.76

Aywy/
Ayfy

3Cx25

6

1.2

0.3

4x0.8

1.60

1.40

1.40

22.5

24.0

880

1120

1.20

1.44

0.097

0.86

Aywy/
Ayfy

3Cx35

6

1.2

0.3

4x0.8

1.60

1.40

1.40

24.0

25.5

1025

1305

0.868

1.04

0.097

0.98

Aywy/
Ayfy

3Cx50

6

1.40

0.3

4x0.8

1.60

1.56

1.56

27.5

29.0

1310

1605

0.641

0.77

0.094

1.02

Aywy

3Cx70

12

1.6

0.4

4x0.8

2.00

1.56

1.56

30.5

33.0

1630

2160

0.443

0.53

0.090

1.18

Aywy/
Ayfy

3Cx95

15

1.6

0.4

4x0.8

2.00

1.56

1.72

34.5

37.5

1990

2645

0.320

0.38

0.090

1.20

Aywy/
Ayfy

3Cx120

15

1.6

0.4

4x0.8

2.00

1.72

1.72

38.0

40.5

2375

3050

0.253

0.30

0.087

1.31

Aywy/
Ayfy

3Cx150

15

1.8

0.5

4x0.8

2.00

1.88

1.88

41.5

44.0

2825

3560

0.206

0.25

0.087

1.31

Aywy/
Ayfy

3Cx185

30

2.0

0.5

4x0.8

2.50

1.88

2.04

45.5

49.0

3365

4590

0.164

0.20

0.087

1.31

Aywy/
Ayfy

3Cx240

30

2.2

0.6

4x0.8

2.50

2.20

2.20

52.0

55.5

4250

5620

0.125

0.15

0.087

1.34

Aywy/
Ayfy

3Cx300

30

2.4

0.6

4x0.8

2.50

2.36

2.36

56.5

60.0

5140

6650

0.100

0.12

0.086

1.41

Aywy/
Ayfy

3Cx400

53

2.6

0.7

4x0.8

3.15

2.52

2.68

64.5

69.5

6270

8720

0.0778

0.09

0.086

1.45

20
3.5 CORE ALUMINIUM PVC ARMOURED POWER CABLES
Type

No. of
cores
&Cross
Sectional
Area

Min
no. of
Wires

Thickne
ss of
PVC
insulatio
n (nom)

Mm

Mi
n
Thi
ckn
ess
of
PV
C
Ou
ter
Sh
eat
h(
m
m)

Nominal
Dimension of
Armour
Strip Wire

Overall
Diameter
(approx)
Strip Wire
Armour
Armour

Appox Net Wt.
of cable

(mm)

(mm)

Min. Thickness
OF pvc outer
strength
Strip Wire
Armour Armour

(Kg/Km)

Strip wire
Armour

Max.D
.C
Resist
ance
at 20

Max
AC
Resist
ance
at 70

Appro
x
React
ance
at
50Hz

Ohms/
km

Approx
.
Capaci
tance

Km

(mm)
Km
Ohms
/km

Aywy/
Ayfy

6/6

1.2/1.0

0.3

4x0.8

1.60

1.40

1.40

25.0

26.5

1000

1260

1.2000

1.44

0.097

0.86

Aywy/
Ayfy

3.5Cx
35/16

6/6

1.2/1.0

0.3

4x0.8

1.60

1.40

1.40

26.0

27.5

1170

1450

0.8680

1.04

0.097

0.98

Aywy/
Ayfy

3.5Cx
50/25

6/6

1.4/120

0.3

4x0.8

1.60

1.56

1.56

29.5

31.0

1470

1805

0.6410

0.77

0.094

1.02

Aywy/
Ayfy

3.5Cx
70/35

12/6

1.4/1.2

0.4

4x0.8

2.00

1.56

1.56

33.5

36.0

1810

2405

0.4430

0.53

0.090

1.18

Aywy/
Ayfy

3.5Cx
95/50

15/6

1.6/1.4

0.4

4x0.8

2.00

1.56

1.72

37.5

40.0

2305

3015

0.3200

0.38

0.090

1.20

Aywy/
Ayfy

3.5Cx
120/70

15/12

1.6/1.4

0.5

4x0.8

2.00

1.72

1.88

41.0

43.0

2760

3545

0.2530

0.30

0.087

1.31

Aywy/
Ayfy

3.5Cx
150/70

15/12

1.8/1.4

0.5

4x0.8

2.00

1.88

1.88

45.5

48.0

3215

4030

0.2060

0.25

0.087

1.31

Aywy/
Ayfy

3.5Cx
185/95

30/15

2.0/1.6

0.5

4x0.8

2.50

2.04

2.04

50.0

53.5

3900

5300

0.1640

0.20

0.087

1.31

Aywy/
Ayfy

3.5Cx
240/120

30/15

2.2/1.6

0.6

4x0.8

2.50

2.20

2.36

57.0

60.0

4840

6390

0.1250

0.15

0.087

1.34

Aywy/
Ayfy

3.5Cx
300/150

30/15

2.4/1.8

0.6

4x0.8

3.15

2.36

2.52

61.5

66.0

5835

8210

0.1000

0.12

0.086

1.41

Aywy/
Ayfy

21

3.5Cx
25/16

3.5Cx
400/185

53/30

2.6/2.0

0.7

4x0.8

3.15

2.68

2.68

70.0

75.0

7250

9900

0.0778

0.09

0.086

1.45
4 CORE ALUMINIUM PVC ARMOURED POWER CABLES
T ype

No. o f
c ores
& Cros s
Sec tion
al A rea

Min
no.
of
W ir
es

T hick ne
s s of
P VC
ins ulatio
n ( nom)
Mm

Min
T hi
c kn
es s
of
PV
C
O ut
er
S he
a th(
mm
)

Nom ina l
Dim ension of
A rm our
Strip /W ire

Min. Thic kness
O F pvc o uter
strength
Strip/W ire
Ar mour

O vera ll
Diam eter
(approx)
Strip/ W ire
A rm our

Appo x Net
W t. of cable

(m m )

(m m)

( mm )

(K g/K m)

S trip /wir e
Arm our

M ax.D.
C
Res is t
ance at
20

M ax
AC
Resi
s tan
ce at
70

Ap pro
x
R eact
anc e
at
50Hz

A ppr
ox .
Capa
c itan
ce

Ohm s
/km

O hm
s/km

Km

Km

A yw y

4CX 1 .5

1

0.8

0 .3

-

1.40

-

1.24

-

14 .5

-

470

18 .100 0

21 .72

0.126

0.14

A yw y

4CX 2 .5

1

0.9

0 .3

-

1.40

-

1.24

-

16 .0

-

560

12 .100 0

14 .52

0.119

0.15

A yw y

4C X 4

1

1.0

0 .3

-

1.40

-

1.24

-

17 .5

-

675

7.4100

8.89

0.116

0.41

1

1.0

0 .3

-

1.40

-

1.24

-

19 .0

-

800

4.6100

5.53

0.110

0.47

1

1.0

0 .3

4x0.8

1.60

1.40

14 0

21.5

23 .0

80 0

1 030

3.0800

3.70

0.100

0.56

6

1.0

0 .3

4x0.8

1.60

1.40

1.40

23.0

25 .0

83 0

1 050

1.9100

2.29

0.097

0.76

6

1.2

0 .3

4x0.8

1.60

1.40

1.40

25.0

27 .0

1075

1 350

1.2000

1.44

0.097

0.86

6

1.2

0 .3

4x0.8

1.60

1.40

1.40

27.5

30 .0

1280

1 620

0.8680

1.04

0.097

0.98

6

1.4

0 .4

4x0.8

2.00

1.56

1.56

32.0

34 .5

1620

2 175

0.6410

0.77

0.094

1.02

12

1.4

0 .4

4x0.8

2.00

1.56

1.56

36.5

38 .0

2010

2 660

0.4430

0.53

0.090

1.18

A yw y

4C X 6

A yw y
/A yfy

4CX 10

A yw y
/A yfy

4CX 16

A yw y
/A yfy

4CX 25

A yw y
/A yfy

4CX 35

A yw y
/A yfy

4CX 50

A yw y
/A yfy

4CX 70

A yw y
/A yfy

4CX 95

15

1.6

0 .4

4x0.8

2.00

1.72

17 2

40.0

42 .5

2550

3 280

0.3200

0.38

0.090

1.20

A yw y
/A yfy

4C X 120

15

1.6

0 .5

4x0.8

2.00

1.88

1.88

44.5

47 .0

3040

3 840

0.2530

0.30

0.087

1.31

A yw y
/A yfy

4C X 150

15

1.8

0 .5

4x0.8

2.50

1.88

2.04

48.0

51 .0

3580

4 880

0.2060

0.25

0.087

1.31

A yw y
/A yfy

4C X 185

30

2.0

0 .6

4x0.8

2.50

2.04

2.20

53.0

57 .0

4340

5 810

0.1640

0.20

0.087

1.31

A yw y
/A yfy

4C X 240

30

2.2

0 .6

4x0.8

2.50

2.36

2.36

60.0

64 .0

5460

7 050

0.1250

0.15

0.087

1.34

A yw y
/A yfy

4C X 300

30

2.4

0 .7

4x0.8

3.15

2.52

2.68

60.5

71 .0

6630

9 260

0.1000

0.12

0.086

1.41

A yw y
/A yfy

4C X 400

53

2.6

0 .7

4x0.8

3.15

2.84

2.84

73.0

78 .0

8185

11020

0.0778

0.09

0.086

1.45

22
ARMOURED CONTROL CABLE IS: 1554 (Pt-I) -1988
No. of
Crores
&Cross
Sectional
Area NO
x mm 2.

Thic
kne
ss
of
PVC
Insu
latio
n
(No
m)
mm

Standa
rd
Deliver
y
Length
in
Mtrs.

Thick
ness
of
Inners
heath
(min)
Extru
ded
mm

STRIP ARMOURED CABLE
Strip
Size
Mm

2 x 1.5
3 x 1.5
4 x 1.5
5 x 1.5
6 x 1.5
7 x 1.5
10 x 1.5
12 x 1.5
14 x 1.5
16 x 1.5
19 x 1.5
24 x 1.5
27 x 1.5
30 x 1.5
37 x 1.5
2 x 2.5
3 x 2.5
4 x 2.5
5 x 2.5
6 x 2.5
7 x 2.5
10 x 2.5
12 x 2.5
14 x 2.5
16 x 2.5
19 x 2.5
24 x 2.5
27 x 2.5
30 x 2.5
37 x 2.5

23

0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.8
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9
0.9

0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.3
0.4

4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8
4x0.8

Thicknes
s PVC
Outer
Sheath
(Min)
Mm

Approx.
OD

1.24
1.40
1.40
1.40
1.40
1.40
1.40
1.40

1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.56
1.56

WIRE ARMOURED CABLE

Approx.
Net
weight
of cable
Kg/km

Roun
d
WireD
ia

19.5
20.8
21.7
23.1
26.4
26.9
27.8
29.7

760
830
920
1040
1250
1355
1430
1670

21.8
22.8
23.8
24.9
26.1
30.0
30.6
32.0
34.7

900
1020
1130
1210
1355
1655
1770
1940
2300

1.4
1.4
1.4
1.4
1.4
1.4
1.4
1.8
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.2
2.2

Mm

Current
Rating

Thickness
PVC Outer
Sheath
(Min)
Mm

Approx.
OD

1.24
1.24
1.24
1.24
1.24
1.24
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.40
1.24
1.24
1.24
1.24
1.24
1.24
1.40
1.40
1.40
1.40
1.40
1.56
1.56
1.56
1.56

13.6
14.1
15.0
15.9
16.9
16.9
20.6
21.5
22.4
23.3
24.7
28.0
28.5
29.4
31.3
14.8
15.4
16.4
17.5
18.7
18.7
23.4
24.4
25.4
26.5
27.7
32.0
32.6
33.6
37.1

Mm

Approx.
New
Weight
of cable
Kg/km

Direct
in
Groun
d

mm

In Air/
Duct.
Amps

Amps

415
430
490
545
604
630
835
950
1040
1130
1265
1510
1610
1700
1960
500
520
590
660
745
780
1110
1240
1340
1455
1605
1970
2100
2250
2900

1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000
1000

23
21
21
16
15
14
13
12
11
11
10
9
9
9
8
32
27
27
23
21
20
18
17
16
15
14
13
12
12
11

20
17
17
14
13
13
11
10
10
9
9
8
8
7
7
27
24
24
19
18
17
15
14
13
13
12
11
10
10
9
PROCESS FLOW CHART

FOR RUBBER CABLES

24
QUALITY ASSURACE CHART

FOR RUBBER CABLES

25
QUALITY ASSURACE CHART

FOR RUBBER CABLES

26
TABLE- 3
1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR) INSULATED OVERALL
PCP, CSP/TRS SHEATHED FLAT THREE CORE (WITHOUT ECC) CABLE
“ISI MARKED” AS PER IS : 9968/Pt-1/1988

Nominal Cross
Sectional Area

Nominal of
Insulation

Thickness of Sheath
Flat
Flat

Nominal cross
Sectional Area of
Earth

mm2

mm

Twin
mm

Three Continuity Conductor
mm
mm

1.0
1.5
2.5
4
6
10
16

1.0
1.0
1.0
1.0
1.0
1.2
1.2

1.0
1.0
1.10
1.20
1.20
1.3
1.4

1.0
1.1
1.1
1.2
1.2
1.4
1.4

of Conductor
2

2

1.0
1.5
1.5
1.5
2.5
4.0
6.0

TABLE- 2
1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR) INSULATED OVERALL
PCP, CSP/TRS SHEATHED SINGLE-CORE CIRCULAR TWIN CORE THREE CORE THREE & FOUR
CORE CABLE “ISI MARKED” AS PER IS: 9968/Pt-1/1988

Nominal Cross
Sectional Area
of Conductor
mm
1
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630
2

27

Thickness
of Insulation

Single
Core

Twin
Core

Three
Core

Four
Core

mm
1.0
1.0
1.0
1.0
1.0
1.20
1.20
1.40
1.40
1.6
1.6
1.8
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.0

mm
1.0
1.0
1.0
1.0
1.0
1.1
1.1
1.2
1.2
1.3
1.4
1.4
1.5
1.6
1.7
1.8
1.90
2.0
2.2
2.3

mm
1.0
1.0
1.1
1.20
1.2
1.3
1.4
1.5
1.6
1.8
1.9
2.1
2.2
2.4
2.6
2.8
3.0
3.2
-

mm
1.0
1.1
1.1
1.2
1.2
1.4
1.4
1.6
1.7
1.8
2.0
2.2
2.3
2.5
2.7
3.0
3.2
3.4
-

mm
1.1
1.1
1.1
1.2
1.3
1.4
1.5
1.7
1.7
2.0
2.1
2.4
2.5
2.7
2.9
3.2
3.5
3.8
-
TABLE-4
1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR)/SILICON INSULATED
OVERALL PCP, CSP/TRS SHEATHED CABLE SINGLE TWIN, THREE AND FOUR-CORE GLASS
FIBRE BRAIDED AND VARNISHED CABLES AND CORDS “ISI MAREKED” AS PER IS: 9968/Pt1/1988
Nominal Cross-Sectional
Area of Conductor
mm2
0.50
0.75
1
1.5
2.5
4
6
10
16
25
35
50

Thickness of Insulation
Cables for Fixed
Flexible cables or
Wiring
Cords
mm
mm
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.6

1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.2
1.2
1.2
1.4
1.6

TABLE-5
1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR)/SILICON INSULATED
OVERALL PCP, CSP/TRS SHEATHED CABLE SINGLE-CORE, CIRCULAR TWIN, THREE-CORE,
FOUR-CORE AND FIVE CORE
“ISI MARKED” AS PER IS: 9968/Pt-1/1988
Nominal Cross
Sectional Area
of Conductor

Thickness
of Insulation
(ft)

Single
Core

Thickness of Sheath (ts)
Twin
Three
Four
Core
Core
Core

Five
Core

6
16
10
25
35
50
70
95
120
150
185
240
300

1.0
1.2
1.2
1.20
1.4
1.60
1.6
1.80
1.8
2.0
2.2
2.4
2.6

1.6
1.9
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
3.4
3.5
3.6

2.0
2.5
2.4
3.2
3.3
3.5
3.6
3.8
4.0
4.2
4.3
4.6
4.9

2.50
3.2
2.9
-

2.1
2.7
2.5
3.3
3.4
3.6
3.7
4.0
4.1
4.3
4.5
4.8
5.1

2.50
2.9
2.7
3.4
3.5
3.7
3.9
4.1
4.3
4.5
4.8
5.1
5.4

28
WELDING CABLES
COPPER/ALUMINIUM WELDING CABLES WITH HOFR
COVERING/GENERAL PURPOSE ELECTROMETRIC SHEATHED AS
PER IS-9857/1990 “ISI MARKED”
The welding cable is suitable for use where combination of ambient temperature and
temperature rise due to load results a conductor temperature not exceeding 60 °C for
general purpose rubber copound cables and 85°C for general purpose HOFR compound
cables. (Heat resisting, oil resisting and flame retardant).
Copper Conductor
Copper Conductor is of annealed high conductivity copper wire complying to
IS-8130-1984.
Aluminium Conductor
Aluminium Conductor is of Aluminium wire complying to IS-8130-1976.

Nominal Area
of Conductor
mm
16*
25
35
50
70
95
120**
2

TABLE-1
THICKNESS OF COVERING
Redial Thickness
of Covering (tc)
mm
2.00
2.00
2.00
2.20
2.40
2.60
2.80

* For copper conductor only
** For aluminium conductor only

29
TABLE-2
CURRENT RATINGS OF GENERAL PURPOSE RUBBER
COMPOUND COVERED CABLE WITH COPPER CONDUCTIOR
Nominal Area
of Conductor 100%
mm

2

16
25
35
50
70
95

Current Rating as a maximum duly cycle of
85%
60%
30%
20%

A

A

A

A

A

94
125
156
197
248
299

102
136
169
214
269
342

121
161
201
254
320
386

172
228
285
360
453
546

210
279
349
440
555
669

Ambient Air Temperature = 30oc

Maximum Conductor temperature = 60oc

TABLE - 3
CURRENT RATINGS OF GENERAL PURPOSE HOFR COMPOUND
COVERED CABLES WITH COPPER CONDUCTOR
Nominal Area
of Conductor
mm
16
25
35
50
70
95

2

Current Rating at a Maximum duly cycle of
100%
85%
60%
30%
A

A

A

135
177
221
279
352
424

146
192
240
303
382
460

174
228
285
360
454
547

Ambient Air Temperature = 30oc

A
246
343
403
509
643
774

Maximum Conductor temperature = 90oc

30
TABLE -4
CURRENT RATING OF GENERAL PURPOSE RUBBER COMPOUND
COVERED CABLE WITH ALUMINIUM CONDUCTOR
Nominal Area
of Conductor
mm

2

25
35
50
70
95
120

Current Rating as a maximum duly cycle of
100%
85%
60%
30%
20%
A

A

A

A

A

100
123
155
196
237
283

108
133
168
213
257
307

129
159
200
253
306
365

183
225
283
358
433
517

224
275
347
438
530
633

Ambient Air Temperature = 30oc

Maximum Conductor temperature = 60oc
TABLE- 5

CURRENT RATINGS OF GENERAL PURPOSE HOFR COMPOUND
COVERED CABLE WITH ALUMINIUM CONDUCTOR
Nominal Area
of Conductor

Current Rating as a maximum duly cycle of
100%
85%
60%
30%

2

mm
25
35
50
70
95
120

Ambient Air Temperature = 30oc

31

A
144
176
222
280
339
404

A
156
191
241
304
368
438

A
186
227
287
361
438
522

A
263
321
405
511
619
738

Maximum Conductor temperature = 60oc
TABLE - 6
VOLTAGE DROP IN COPPER CONDUCTORS AT NORMAL
AND ELEVATED TEMPERATURES
Nominal Area
of Conductor

DV Voltage Drop/100/A1/210 m of Cable at
20 C

60 C

90 C

mm

V

V

V

16

1.19

1.438

1.587

25

0.780

0.922

1.018

35

0.552

0.655

0.773

50

0.390

0.456

0.503

70

0.276

0.321

0.355

95

0.244

0.244

0.269

2

0

0

0

TABLE - 7
VOLTAGE DROP IN ALUMINIUM CONDUCTORS AT NORMAL
AND ELEVATED TEMPERATURES
Nominal Area

DC Voltage Drop/100A/10 m of Cable at

Sectional Area
of Conductor

20 C

60 C

90 C

mm

V

V

V

25

1.23

1.427

1.574

35

0.901

1.045

1.153

50

0.634

0.735

0.811

70

0.445

0.516

0.570

95

0.334

0.387

0.428

120

0.256

0.297

0.328

2

0

0

0

32
Table 3
STRANDED COPPER AND ALUMINIUM CONDUCTORS
(WEIGHT & DC RESISTANCE AT 200C )

Nominal Area of
Conductor
(sq. mm)

1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

33

Annealed plain Copper
Appox. Weight Max.d.c.resist0
(kgkm)
ance at 20 C
(ohms/km)

9.0
13.3
22.4
36.1
54.0
90.8
145
229
317
429
620
860
1086
1334
1673
2199
2759
3528
4445
5744

18.1
12.1
7.41
4.61
3.08
1.83
1.15
0.727
0.524
0.387
0.268
0.193
0.153
0.124
0.0991
0.0754
0.0601
0.0470
0.0366
0.0283

Approx.
(kgkm)

2.70
4.1
6.8
10.4
16.4
27.7
43.9
69.5
96.4
131
189
262
331
406
409
669
839
1073
1353
1746

Aluminium
Max.d.c.resist0
ance at 20 C
(ohms/km)

29.9
18.1
12.1
7.41
4.61
3.08
1.91
1.20
0.868
0.641
0.443
0.320
0.253
0.206
0.164
0.125
0.100
0.0778
0.0605
0.0469
TABLE -4
FLEXIBLE COPPER CONDUCTORS

Nominal Area of
Conductor
(sq. mm)

Approx.
Weight
(kgkm

1.0
1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240
300
400
500
630

9.5
14.0
23.5
37.9
56.7
95.3
152
240
333
450
651
903
1140
1401
1757
2309
2897
3704
4670
6031

Max. D.C.resistance at 200C (ohms/km)
Annealed plain Copper Annealed tinned
Cooper
19.5
13.3
7.98
4.95
3.30
1.91
1.21
0.780
0.554
0.386
0.272
0.206
0.161
0.129
0.106
0.0801
0.0641
0.0486
0.0384
0.0287

20.0
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
0.393
0.277
0.210
0.164
0.132
0.108
0.0817
0.0654
0.0495
0.0391
0.0292

34
TABLE -5
TEMPERATURE CORRECTION FACTORE FOR
CONDUCTOR RESISTANCE AT DIFFERENT TEMPERATURES

0

Temperature( C)
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
85
90

35

Temperature correction factor for
Copper and Aluminium conductor
0.94
0.96
0.98
1.00
1.02
1.04
1.06
1.08
1.10
1.12
1.14
1.16
1.18
1.20
1.22
1.24
1.26
1.28
VOLTAGE DROP CALCULATIONS
An approximate check can be made on voltage drop by means of the following formulae:
For d.c. and single phase a.c. two wire system:
=

2xIxLxRxt
1000

For three phase a.c. system :
=

1.732 x I x L x R x t
1000

Where I = Current in Amperes.
L = Length of cable run in metres (one conductor only).
R = Resistance in ohms of one conductor only from table 3-4.
T = temperature correction factor from table 5.
Notes:
1) Resistance values for copper and aluminium conductors are shown in table 3 and 4.
2). for conductor cross section above 70sqmm an allowance must be considered for skin and proximity
effect.

USEFUL 3 PHASE FORMULA
KW

=
KVA x power factor
KW =
HP x 746
1000 x efficiency
Line Amps x Line Volts x 1.732 x power factor
1000

=

HP

=

Line Amps x Line Volts x 1.732 x efficiency x p.f.
746

36
TABLE-8
PROPERTIES OF METALS USED IN CABLE

-

Annealed
Copper
8.89

Tensile strength
(Approx.)

Kg/mm2

25

12 to 15

Melting point

Deg. C

1083

659

%

23 to 40

2 to 6

15

30

7000

19000

1600

Properties

Unit

Specific gravity

Elongation
Young’s Modules
of Elasticity

Kg/mm2

Co-efficient of
linear expansion

Deg. C

Specific heat

K cal/kg0C

Thermal resistivity

0

103

9 to 15.5

Aluminium

Steel

Lead

2.703

7.86

11.37

30 to 50

1.8

1400

327

0.217

0.114

C cm/watt

0.25

0.48

2.20

2.96

Specific electrical
resistance at 200C

Microhm/cm

1.7241

2.8264

1405

21.0

Temp. co-efficiect
of resistance at
20oC

37

0.093

29
10-6
0.031

Per deg.C

0.00393

0.00403

0.0042

0.0042

17

10-6

23

10-6

11.5

10-6
TABLE 9
PERFORMANCE AND SELECTION OF COMMONLY USED THERMOPLASTIC CABLES
INSULATING AND SHEATHING MATERIALS

General
purpose
PVC
insulation
ty pe A to
IS5831/84

Material

General
purpose
PVC
insulation
ty pe B to
IS5831/84

Heat
resisting
PVC
insulation
ty pe C to
IS5831/84

Max. cond. Tem. For
0
continous operation ( C)

General
purpose
PVC
sheath
ty pe ST 1
to IS5831/84

70

Heat resisting
PVC sheath
ty pe ST 2 to
IS-5831/84

Low
Temp.
PVC

Special
Heat
resistin
g PVC

105

Poly tertre
f luro
ethy lene
(PTFE)

Fluorinated
ethy len
e
propy le
ne
(FEP)

70

260

200

Poly ethy lene

90

70

160

160

160

160

130

500

250

-20

-15

-40

-30

-60

-75

-75

E

E

E

E

E

E

G

G

E

E

E

E

E

E

P

P

P

G

G

G

G

G

G

G

P

E

E

Oil

G

G

G

G

G

G

G

F

E

E

Water

G

E

G

G

G

G

G

G

E

E

Chemical

G

G

G

G

G

G

G

G

E

E

Solv ents

F

F

F

F

F

F

F

G

E

E

Abrasions

G

E

E

G

E

G

E

E

E

E

70

70

85

160

160

160

-20

-15

-15

E

E

Coronaz

E

Weather

Max. cond. Temp . at
the termination of
0
shorty circuit ( C)
0

Min. working temp. ( C)
Resistance to Ozone

Flame resistance
Electricals

E

E

E

E

E

E

E

P

E

E

Insulation resistance

G

E

E

NA

NA

G

E

E

E

E

Voltage breakdown

G

G

G

NA

NA

G

G

E

E

E

A.C.Losses

F

F

F

NA

NA

F

F

E

E

E

E- EXCELLENT : G- GOOD: F –FAIR: P- POOR: NA- NOT APPLICABLE

38
TABLE 10
PERFOMANCE AND SELECTION OF COMMONLY USED ELASTOMERIC CABLES
INSULATING AND SHEATHING MATERIALS

Natureal
Rubber
(VIR
&TRS)in
cluding
blends with
SBR

M aterial

Max. cond. Tem. For
continous operation
(0 C)

Heat
Resist-ing
Natural
rubber
HRVIR

Ethylene
propylen
e rubber
EPR

Polychlo
roprene
rubber
PCP

90

Nitrile
Butadiene
rubber
blend with
PVC
(NBRPVC)

Chlorosulp
h-onated
polyethylen
e rubber
CSP

Cross
linked
Polyethy
lene
(XLPE)

90

Silicon
rubber

150/180

90

90

200

200

200

250

350

-50

-40

-30

-35

-40

-55

P

E

G

G

E

G

E

P

P

E

NA

NA

G

P

G

Weather

P

F

G

E

G

E

G

E

Oil

P

P

P

G

E

G

G

P/F

Water

G

G

G

F

G

G

G

G

Chemical

F

F

G

F

F

G

G

F

Solvents

P

P

P

G

G

G

G

G

Abrasions
Flame resistance
Electrical
Insulation resistance

F

F

P

G

G

G

G

P/F

P

P

P

E

G

E

P

E

G

G

G

NA

NA

F

E

F

Vo ltage breakdown

G

G

G

NA

NA

G

E

G

A.C.Losses

G

G

G

NA

NA

F

E

G

60

75

200

200

-55

-55

P

Corona

Max. cond. Temp . at
the termination of
shortly circuit (0 C)
Min. working temp.
(0 C)
Resistance to Ozone

90

250

E- EXCELLENT : G- GOOD: F –FAIR: P- POOR: NA- NOT APPLICABLE

39
TELEPHONE CABLES
1.

Telephone Switch Bard Multicore Cables are being extensively used by
Telephone Depart ment, Govt.Departments, railway and other industries in
their telecommunication network.

2.

Conductor : Annealed tinned-electrolytic copper conductors, PVC colour coded
as per ITO Specification D-3003 ITD-S/WS-1138 or S/WS-1148 each wire twisted
with its mate wire in a right hand lay and each such pair twisted with its make wire
in a right hand lay and each such pair twisted with respect to all other airs in
concentric layers so as to supress cress talk. The conductors shall be 0.5, 0.6, 0.7
or 0. 9 mm Dia. and Cables are manufactured in one pair size to 100 pairs as per
costomers requirements.

3.

Insulation : Hard Grade PVC with nominal radial thickness.

4.

Colour Scheme : As per I.T.I.D. 3003,ITD S/WS-113B OF S/WB-114B.

5.

Armouring : The armouring shall consist of galvanised steel wires having nominal
diameter of 1.4 mm for Cables having inner sheathed diameter uto 13mm in
Cables where the diameter of inner sheathing exceeds 13 mm, steel striof size 4 x
0.8 mm is to be used.

6.

Sheathing : The outer sheath shall be extruded PVC Compound specially
designed to afford high degree of mechanical chemical and Thermal Properties.
RECOMMENDATIONS FOR INSTALLATION
The following are some of the salient factors which should be kept in view during
installation of PVC Insulated Heavy Duty Cables :

1.

Before laying, the insulation of the cable should be checked with megger as a
preliminary check against any probably damage.

2.

The drum should be always rolled in the "direction of arrow for rolling" marked on
the drum. In the absence of any such mark, the drum should be rolled in the
direction same as that of inside and of the cable and opposite to that of the outside
end.

3.

Where the cable is to be jointed with existing cable, the sequence of cores at the
two ends to be jointed should be in the opposite direction i.e. If at one end it is in
clockwise direction, at the other end it should be in anticlockwise direction. This is
necessary to avoid the crossing of cores while jointing. This will also decide the
direction in which the cable is to be pulled.

4.

Wherever possible bending radius of 12 times the overall diameter of the cable
should be maintained, but in any case it should not be less than 8 times.

40
5.

6.

7.

Where the cables are necessarily laid and jointed in very cold regions both the
cable and the ambient temperature should be above OC and have remained so
for the previous 24 hours. During such conditions, the cable should also not be
bent to ver small radius.
A joint being the weakest point of the electric power transmission system, all
necesaary precautions shuld be taken. Jointing materials and accessories like
conductiors ferules, solder, insulating and protective tapes, protective filling
compound, joint boxes etc. of right quality and sized should be procured. The
application of these materials should be made skilfully for joining work. In this
connection, it is always advisable that the method and the working instructions of
the supplier should be strictly followed.
Armoured Cables : All bonding clamps at the joints and terminations and the
armour wires should be thoroughly cleaned. The clamps should be adequately
tightened. This is necessary to ensure proper electrical contact, because armour
is the only return path for earth fault current.
Unarmoured Cables : In case of unarmoured cables, the external metallic earth
bodding connector of adequate sizes should be used.

8.

Earth : All joints, terminations, armour wires and external metallic bonding should
be connected to earth. Wherever possible, armour at one end of the cable should
be connected to main earth system at the supplying end by employing metallic
connectors.
Precautions should be taken to eliminate the chemical and bimetallic corrosion of
the earth connectors or bonds.

9.

Filling Compunds :
a) The design of the box and the cimposition of the filling compound should
provide an effective saving against entry of moisture to conductor ferrules and
a hour connector.
b) If not pouring protective compounds, are used, the temperatures of the
compound whicl pouring should not exceed 100 C.
0

10.

Test after installion : After the cable is installed, a voltage test may be carried out.
Each core should be tested at 4KV against others and the armour, the latters
connected to the earth.
The voltage should be injcreased gradually to full value and maintained
continuously for 15 minutes. No breakdown of insulation occur during the test.

41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60

Más contenido relacionado

Destacado

Wire Strand Chart
Wire Strand ChartWire Strand Chart
Wire Strand ChartMaryArmenta
 
Catalog (eastern cables)_book
Catalog (eastern cables)_bookCatalog (eastern cables)_book
Catalog (eastern cables)_bookEngr Nizam Mfa
 
11 h0001x00 anixter-wc-technical-handbook-en-us
11 h0001x00 anixter-wc-technical-handbook-en-us11 h0001x00 anixter-wc-technical-handbook-en-us
11 h0001x00 anixter-wc-technical-handbook-en-usadnan201413
 
Catalogue tai sin www.thietbidienngan.com-2014
Catalogue tai sin  www.thietbidienngan.com-2014Catalogue tai sin  www.thietbidienngan.com-2014
Catalogue tai sin www.thietbidienngan.com-2014Ngan TNHH
 
Cadweld welded electrical conections
Cadweld welded electrical conectionsCadweld welded electrical conections
Cadweld welded electrical conectionsNam Pham
 
Current carrying capacities & other technical tables
Current carrying capacities & other technical tablesCurrent carrying capacities & other technical tables
Current carrying capacities & other technical tablesasif raza
 
Raxton brochure 2009 issue09
Raxton brochure 2009 issue09Raxton brochure 2009 issue09
Raxton brochure 2009 issue09AKBAR TRADING
 
Mf design guidelines
Mf design guidelinesMf design guidelines
Mf design guidelinesAverill Cook
 
Power Control Cables - Nuhas Oman Catalogue
Power Control Cables - Nuhas Oman CataloguePower Control Cables - Nuhas Oman Catalogue
Power Control Cables - Nuhas Oman Cataloguenuhasoman
 
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDF
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDFINTERIOR DESIGNER CV 2017 (ROLUTHON).PDF
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDFRoluthon Ouseph
 
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-0013melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001Ponlue Smile
 
Abb xlpe land cable system user's guide
Abb xlpe land cable system user's guideAbb xlpe land cable system user's guide
Abb xlpe land cable system user's guideSherpa Kusang
 
Xlpe land cable systems 2 gm5007gb rev 5
Xlpe land cable systems 2 gm5007gb rev 5Xlpe land cable systems 2 gm5007gb rev 5
Xlpe land cable systems 2 gm5007gb rev 5Tien Nguyen
 
แคตตาล๊อคปก4
แคตตาล๊อคปก4แคตตาล๊อคปก4
แคตตาล๊อคปก4prapai faifa
 

Destacado (20)

Wire Strand Chart
Wire Strand ChartWire Strand Chart
Wire Strand Chart
 
Catalog (eastern cables)_book
Catalog (eastern cables)_bookCatalog (eastern cables)_book
Catalog (eastern cables)_book
 
11 h0001x00 anixter-wc-technical-handbook-en-us
11 h0001x00 anixter-wc-technical-handbook-en-us11 h0001x00 anixter-wc-technical-handbook-en-us
11 h0001x00 anixter-wc-technical-handbook-en-us
 
Xlpe insulated cables
Xlpe insulated cablesXlpe insulated cables
Xlpe insulated cables
 
Catalogue tai sin www.thietbidienngan.com-2014
Catalogue tai sin  www.thietbidienngan.com-2014Catalogue tai sin  www.thietbidienngan.com-2014
Catalogue tai sin www.thietbidienngan.com-2014
 
Cable
CableCable
Cable
 
Cadweld welded electrical conections
Cadweld welded electrical conectionsCadweld welded electrical conections
Cadweld welded electrical conections
 
Current carrying capacities & other technical tables
Current carrying capacities & other technical tablesCurrent carrying capacities & other technical tables
Current carrying capacities & other technical tables
 
XLPE Land Cable System
XLPE Land Cable SystemXLPE Land Cable System
XLPE Land Cable System
 
Nec ampacities
Nec ampacitiesNec ampacities
Nec ampacities
 
Raxton brochure 2009 issue09
Raxton brochure 2009 issue09Raxton brochure 2009 issue09
Raxton brochure 2009 issue09
 
Mf design guidelines
Mf design guidelinesMf design guidelines
Mf design guidelines
 
Power Control Cables - Nuhas Oman Catalogue
Power Control Cables - Nuhas Oman CataloguePower Control Cables - Nuhas Oman Catalogue
Power Control Cables - Nuhas Oman Catalogue
 
Wiring accessories-ellelite-electric 2015
Wiring accessories-ellelite-electric 2015Wiring accessories-ellelite-electric 2015
Wiring accessories-ellelite-electric 2015
 
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDF
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDFINTERIOR DESIGNER CV 2017 (ROLUTHON).PDF
INTERIOR DESIGNER CV 2017 (ROLUTHON).PDF
 
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-0013melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001
3melectricalcatalogue lowhighvoltagecableaccessoriesscotchcastcoldshrink-001
 
Abb xlpe land cable system user's guide
Abb xlpe land cable system user's guideAbb xlpe land cable system user's guide
Abb xlpe land cable system user's guide
 
Xlpe land cable systems 2 gm5007gb rev 5
Xlpe land cable systems 2 gm5007gb rev 5Xlpe land cable systems 2 gm5007gb rev 5
Xlpe land cable systems 2 gm5007gb rev 5
 
Failure of fuse & mcb
Failure of fuse & mcbFailure of fuse & mcb
Failure of fuse & mcb
 
แคตตาล๊อคปก4
แคตตาล๊อคปก4แคตตาล๊อคปก4
แคตตาล๊อคปก4
 

Similar a Shyam Cable Industries product range and quality control guide

Jmv presentation smart process plant
Jmv  presentation  smart process plantJmv  presentation  smart process plant
Jmv presentation smart process plantMahesh Chandra Manav
 
Presentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdPresentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdAruna Narayan
 
Presentation Smart Hospital Projects and JMV LPS Ltd
 Presentation  Smart Hospital Projects  and JMV LPS Ltd Presentation  Smart Hospital Projects  and JMV LPS Ltd
Presentation Smart Hospital Projects and JMV LPS LtdMahesh Chandra Manav
 
Jmv presentation smart hospital projects india-1
Jmv  presentation  smart hospital projects india-1Jmv  presentation  smart hospital projects india-1
Jmv presentation smart hospital projects india-1Mahesh Chandra Manav
 
Jmv Presentation Airport and JMV LPS LTD
Jmv Presentation Airport and JMV LPS LTDJmv Presentation Airport and JMV LPS LTD
Jmv Presentation Airport and JMV LPS LTDMahesh Chandra Manav
 
360786862-Indice-de-Normas.pdf
360786862-Indice-de-Normas.pdf360786862-Indice-de-Normas.pdf
360786862-Indice-de-Normas.pdfEduardo Bas
 
Havells cables and wires.
Havells cables and wires.Havells cables and wires.
Havells cables and wires.Havells India
 
Popular Systems, Coimbatore, Electrical Components
Popular Systems, Coimbatore, Electrical ComponentsPopular Systems, Coimbatore, Electrical Components
Popular Systems, Coimbatore, Electrical ComponentsIndiaMART InterMESH Limited
 
Jmv presentation smart solar power
Jmv  presentation  smart solar power  Jmv  presentation  smart solar power
Jmv presentation smart solar power Mahesh Chandra Manav
 
Inoxtech Presentation Marbella 11 Nov 08
Inoxtech Presentation Marbella 11 Nov 08Inoxtech Presentation Marbella 11 Nov 08
Inoxtech Presentation Marbella 11 Nov 08Mattia Agnoletto
 
Professional electrical testing services in delhi
Professional electrical testing services in delhiProfessional electrical testing services in delhi
Professional electrical testing services in delhiSpectro Group of Companies
 
Electrical component at airport for airfield lighting circuit
Electrical component at airport for airfield lighting circuitElectrical component at airport for airfield lighting circuit
Electrical component at airport for airfield lighting circuitRLarivee
 
Final power point teckno profile
Final power point teckno profileFinal power point teckno profile
Final power point teckno profileJanakbhatt
 
cv-ramez-2016 new
cv-ramez-2016 newcv-ramez-2016 new
cv-ramez-2016 newRamez Nasr
 
Itt grinnell products standard and line pipe catalog 2008
Itt grinnell products standard and line pipe catalog 2008Itt grinnell products standard and line pipe catalog 2008
Itt grinnell products standard and line pipe catalog 2008ITTGRINNELL
 
Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Mahesh Chandra Manav
 
Presentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsPresentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsMahesh Chandra Manav
 

Similar a Shyam Cable Industries product range and quality control guide (20)

Jmv presentation smart process plant
Jmv  presentation  smart process plantJmv  presentation  smart process plant
Jmv presentation smart process plant
 
Presentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt LtdPresentation-Telemetrics Equipments Pvt Ltd
Presentation-Telemetrics Equipments Pvt Ltd
 
ATS-Catalogue-Latest
ATS-Catalogue-LatestATS-Catalogue-Latest
ATS-Catalogue-Latest
 
Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATS
Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATSCatalogue-Oil Cooled-Resin Cast CTs-PTs-ATS
Catalogue-Oil Cooled-Resin Cast CTs-PTs-ATS
 
Presentation Smart Hospital Projects and JMV LPS Ltd
 Presentation  Smart Hospital Projects  and JMV LPS Ltd Presentation  Smart Hospital Projects  and JMV LPS Ltd
Presentation Smart Hospital Projects and JMV LPS Ltd
 
Jmv presentation smart hospital projects india-1
Jmv  presentation  smart hospital projects india-1Jmv  presentation  smart hospital projects india-1
Jmv presentation smart hospital projects india-1
 
Tempsens- cable and wires
Tempsens- cable and wiresTempsens- cable and wires
Tempsens- cable and wires
 
Jmv Presentation Airport and JMV LPS LTD
Jmv Presentation Airport and JMV LPS LTDJmv Presentation Airport and JMV LPS LTD
Jmv Presentation Airport and JMV LPS LTD
 
360786862-Indice-de-Normas.pdf
360786862-Indice-de-Normas.pdf360786862-Indice-de-Normas.pdf
360786862-Indice-de-Normas.pdf
 
Havells cables and wires.
Havells cables and wires.Havells cables and wires.
Havells cables and wires.
 
Popular Systems, Coimbatore, Electrical Components
Popular Systems, Coimbatore, Electrical ComponentsPopular Systems, Coimbatore, Electrical Components
Popular Systems, Coimbatore, Electrical Components
 
Jmv presentation smart solar power
Jmv  presentation  smart solar power  Jmv  presentation  smart solar power
Jmv presentation smart solar power
 
Inoxtech Presentation Marbella 11 Nov 08
Inoxtech Presentation Marbella 11 Nov 08Inoxtech Presentation Marbella 11 Nov 08
Inoxtech Presentation Marbella 11 Nov 08
 
Professional electrical testing services in delhi
Professional electrical testing services in delhiProfessional electrical testing services in delhi
Professional electrical testing services in delhi
 
Electrical component at airport for airfield lighting circuit
Electrical component at airport for airfield lighting circuitElectrical component at airport for airfield lighting circuit
Electrical component at airport for airfield lighting circuit
 
Final power point teckno profile
Final power point teckno profileFinal power point teckno profile
Final power point teckno profile
 
cv-ramez-2016 new
cv-ramez-2016 newcv-ramez-2016 new
cv-ramez-2016 new
 
Itt grinnell products standard and line pipe catalog 2008
Itt grinnell products standard and line pipe catalog 2008Itt grinnell products standard and line pipe catalog 2008
Itt grinnell products standard and line pipe catalog 2008
 
Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)Worldwide Lightning called as Disaster not as Guest(SACHET)
Worldwide Lightning called as Disaster not as Guest(SACHET)
 
Presentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lpsPresentation lightning protection system by jmv lps
Presentation lightning protection system by jmv lps
 

Último

Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation SlidesKeppelCorporation
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailAriel592675
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Pereraictsugar
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Kirill Klimov
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy Verified Accounts
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfrichard876048
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607dollysharma2066
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...lizamodels9
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...lizamodels9
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...lizamodels9
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadAyesha Khan
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Seta Wicaksana
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...lizamodels9
 
Marketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent ChirchirMarketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent Chirchirictsugar
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menzaictsugar
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Riya Pathan
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?Olivia Kresic
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Timedelhimodelshub1
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessSeta Wicaksana
 

Último (20)

Keppel Ltd. 1Q 2024 Business Update Presentation Slides
Keppel Ltd. 1Q 2024 Business Update  Presentation SlidesKeppel Ltd. 1Q 2024 Business Update  Presentation Slides
Keppel Ltd. 1Q 2024 Business Update Presentation Slides
 
Case study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detailCase study on tata clothing brand zudio in detail
Case study on tata clothing brand zudio in detail
 
Kenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith PereraKenya Coconut Production Presentation by Dr. Lalith Perera
Kenya Coconut Production Presentation by Dr. Lalith Perera
 
Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024Flow Your Strategy at Flight Levels Day 2024
Flow Your Strategy at Flight Levels Day 2024
 
Buy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail AccountsBuy gmail accounts.pdf Buy Old Gmail Accounts
Buy gmail accounts.pdf Buy Old Gmail Accounts
 
Innovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdfInnovation Conference 5th March 2024.pdf
Innovation Conference 5th March 2024.pdf
 
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607FULL ENJOY Call girls in Paharganj Delhi | 8377087607
FULL ENJOY Call girls in Paharganj Delhi | 8377087607
 
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
Call Girls In Radisson Blu Hotel New Delhi Paschim Vihar ❤️8860477959 Escorts...
 
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
Lowrate Call Girls In Sector 18 Noida ❤️8860477959 Escorts 100% Genuine Servi...
 
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
Call Girls In Sikandarpur Gurgaon ❤️8860477959_Russian 100% Genuine Escorts I...
 
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in IslamabadIslamabad Escorts | Call 03070433345 | Escort Service in Islamabad
Islamabad Escorts | Call 03070433345 | Escort Service in Islamabad
 
Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...Ten Organizational Design Models to align structure and operations to busines...
Ten Organizational Design Models to align structure and operations to busines...
 
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In.../:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
/:Call Girls In Indirapuram Ghaziabad ➥9990211544 Independent Best Escorts In...
 
Marketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent ChirchirMarketplace and Quality Assurance Presentation - Vincent Chirchir
Marketplace and Quality Assurance Presentation - Vincent Chirchir
 
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu MenzaYouth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
Youth Involvement in an Innovative Coconut Value Chain by Mwalimu Menza
 
Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737Independent Call Girls Andheri Nightlaila 9967584737
Independent Call Girls Andheri Nightlaila 9967584737
 
MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?MAHA Global and IPR: Do Actions Speak Louder Than Words?
MAHA Global and IPR: Do Actions Speak Louder Than Words?
 
Call Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any TimeCall Girls Miyapur 7001305949 all area service COD available Any Time
Call Girls Miyapur 7001305949 all area service COD available Any Time
 
Japan IT Week 2024 Brochure by 47Billion (English)
Japan IT Week 2024 Brochure by 47Billion (English)Japan IT Week 2024 Brochure by 47Billion (English)
Japan IT Week 2024 Brochure by 47Billion (English)
 
Organizational Structure Running A Successful Business
Organizational Structure Running A Successful BusinessOrganizational Structure Running A Successful Business
Organizational Structure Running A Successful Business
 

Shyam Cable Industries product range and quality control guide

  • 1. SHYAM CABLE INDUSTRIES All Types Of Cables Manufacturer Company Engineering Customized Power Solutions
  • 2. WELCOME TO OUR COMPANY Chapter Page No. INTRODUCTION PRODUCT RANGE 2 LIST OF GOVERNMENT CLIENTS 3 LIST OF OTHER REPUTED CLIENTS 4 LIST OF MACHINERY 5 LIST OF TESTING EQUIPMENTS 6 QUALITY CONTROL 7 CURRENT RATING 8 PROCESS FLOW CHART (PVC CABLES) 9 QUALITY ASSURANCE PLAN (PVC CABLES) 10 CONSTRUCTION OF POWER CABLES 14 PROCESS FLOW CHART (RUBBER CABLES) 23 QUALITY ASSURANCE PLAN (RUBBER CABLES) 24 TECHNICAL OF ELASTOMERIC CABLES 26 TECHNICAL OF WELDING CABLES 28 PROPERTIES OF RAW MATERIAL USED 33 TELEPHONE CABLES 40 LIST OF REGISTRATION CERTIFICATE & PERFORMANCE CERTIFICATES 42 LIST OF PURCHASE ORDERS 1 1 52
  • 3. SALIENT FEATURES 1. Well equipped and most modern laboratory having ISO-9001 and ISI carrying out extensive tests from raw materials to final products at various stages. 2. Cables manufacturing conforming to various National and International specifications having four “BIS” License: 9968/Pt-I/1988, 1554/Pt-1/1988, 9857/90 & 694/90. 3. Approval accorded by a number of Organisations and Inspection agencies of International repute like IFFCO, BHEL, NLC, RSP, BSP, SAIL, ONGC, NTPC, DGS&D, Air Hqs., DGQA (Naval) LGT, MECON, PDIL etc. 4. Specialisation in Elastometric / Flexible Cables (Butyl/EPR, PCP /CSP and Silicon Rubber Cables) 5. 40 successful years of regular supply to numerous Government Departments / Public / Private Sector Industrial Enterprises. 6. 80% of Production ongoing to Government Department and reputed public Sector Undertaking all over the country. CLIENTELE Our more than 40 years of journey towards service with excellence has given us numerous all over India in all the sectors of the India Economy, 80% of them in government / Public Sector. Today hundreds of industrial enterprises rely on Shyam Cable in the key sectors like Steel plants, Power Projects, Aeronautics, Ordnance factories, Railways, Fertilizer Plants, Atomic Energy, Air Force, Petroleum, Navy, Shipyards, Mines, Power Stations, Oil & Natural Gas, Port Trusts, Coalfields, Heavy Engineering, Telecommunication. Electrical and Electronics, Wind Energy and so on. 2
  • 4. PRODUCTS S.No. Type of Cables upto) Specification Size (Including & No of cores x Area in Sq.mm 1. Elastomeric Cables (VIR/TRS, EPR, PCP/CSP & Silicon Rubber Insulated Cables) 2. Power & Controls Cables (Armoured /Unarmoured PVC Insulated & Sheathed) 3. Welding Cables (Copper & Aluminium) 5. PVC Wires/Cables Lighting Cables Screened Cables Instrumentation Cables Compensating Cables “ 1 x 1000 3.5 x 630 61 x 2.5 IS: 1554/88/Pt-1 ISI Marked” 1 x 1000 3.5 x 630 61 x 2.5 IS: 9968/88/Pt-1 & Pt-II Upto 6.6/11 KV “ Trailing Cables 4. IS: 9968/88/Pt-1 “ISI Marked” 1 x 1000 3.5 x 630 61 x 2.5 IS: 9857/90 ISI Marked” All Sizes IS: 694/90 “ISI Marked” All Sizes IS: 5608 IS: 8784 6. IS: 1554/88 All Sizes 7. Telephone Cables (Armoured /Unarmoured) ITD-3003 G/WIR-06/02 100 Pairs 8. Submersible Flat Cables IS: 694/90 IS: 9968/88/Pt-1 61 x 2.5 4 x 400 9. XLPE Cables (Armoured/ Unarmoured XLPE Insulated & Sheathed Cables) IS: 7098 1 x 1000 3.5 x 630 61 x 2.5 10. 3 FRLS Cables ASTM/D-2843 Kynar / HMWPE All Sizes
  • 5. LIST OF GOVERNMENT CLIENTS S A I L / BHILAI STEEL PLANT BEML S A I L / BOKARO STEEL PLANT NTPC S A I L / ROURKELA STEEL PLANT ONGC S A I L / DURGAPUR STEEL PLANT NALC O NEYVELI LIGNITE CORP. LTD. NHPC B H E L (HARIDWAR & TIRUCHIRAPALLI) GAIL (INDIA) LIMIITED DAMODER VALLEY CORPORATION TRIVENI STRUCTURALS LTD. R C F (KAPURTHALA) NATIONAL MINERALS DEVELOPMENT CORP. LTD. MAZGOAN DOCK LTD. VISHAKHAPATNAM PORT TRUST NATIONAL FERTILIZER LIMITED I F F C O Limited NUMALIGARH REFINERY LIMITED URANIUM CORPORATION INDIA LIMITED THERI HYDRO DEVP. CORP. LTD. BONGAIGAON REFINERY & PETROCHEMICALS LTD. CONTAINER CORP. OF IND. LTD. PANIPAT THERMAL POWER STATION N.E.E.P.C.O. LIMITED COAST GUARD ORDNANCE FACTORIES NAVAL (MUMBAI, KOCHI, GOA) HINDUSTAN STEEL WORKS CONS. LTD. BHARAT HEAVY PLATES & VESSELS LTD. INDIA AIR FORCE CHENNAI PORT TRUST SATLUJ JAL VIDYUT NIGAM LTD. VISAKHAPATNAM STEEL PLANT NORTHERN RAILWAYS MEC0N LTD. P.D.I.L INDIAN OIL CORP. LTD. 4
  • 6. LIST OF OTHER REPUTED CLIENTS RELIANCE INDUSTRIES LIMITED ENERCON RELIANCE PETROLEUM LIMITED GUJARAT AMBUJA CEMENT ELECON ENGINEERING CO. LTD. BHUSHAN STEEL LTD. FENNER INDIA LTD. JINDAL STAINLESS LTD. ISGEC JINDAL PIPE LTD. DC M SHRIRAM (DAURALA) SIEMENS LIMITED BALCO L&T LTD. A.B.B. LTD. ADANI GROUP ESSAR GROUP JINDAL STEEL & POWER PRAKASH INDUSTRIES LIMITED SUZLON ENERGY LTD. MUKAND LIMITED BEEKAY ENGG. CORPORATION RATHI SUPER STEEL LIMITED BAJAJ HINDUSTAN LTD. MONNET ISPAT & ENERGY LTD. SIMPLEX ENGG. & FOUNDRY WORKS (P) LTD. . 5 .
  • 7. LIST OF MACHINERY PVC Extruders (150 mm) Kneader PVC Extruders (100 mm) PVC Mixtures PVC Extruders (75 mm) Rubber Mixing Mills PVC Extruders (40 mm) M.S. Vulcanisers Complete with Rubber Extruders (100 mm) Rubber Extruders (75 mm) Rubber Extruders (40 mm) Tray and stand. Bale Cutting Machine Wire Stranding & Trapping Machines Taping Heads High Speed Bunching Machine Armouring Machines Braiding Machines of various sizes Core Printing Machine Sequential length marking machine M. S. Trolley Laying Machines Spooling Machines High Speed Bunching Welding Machine Oil Fired Boiler 6
  • 8. LIST OF TESTING EQUIPMENTS AC High Voltage Tester 10 KV AC High Voltage Tester 30 KV Mandral for Bending Test Double Kelvin Bridge Dombell Die with Stand Million Meghohms Meter Tear Resistance Attachment Hot Deformation Test Apparatus Air & Oxygen Bomb Apparatus Volumetric Test Apparatus Oxygen Cylinder Annealing Test Apparatus Meggar Hot Water Bath Spark Tester DC High Voltage Air Compressor Hydraulic Press Tensile Testing Machine Capacitance Meter Travelling Microscope Flamability Test Apparatus Flame Resistance Test Apparatus Standard Resistance Box Hot set Test Apparatus Micrometer Humidity Conditioning Chamber Digital Milliohm Meter Ozone Test Apparatus Air Hot Oven Cold Band Test Apparatus Fault Locator Smoke Density Physical Balance Oxygen Index Multimeter Halogen Acid Gas Generation Ageing Oven Swedish Chimney Ageing Air Oven 7 Single Pan Electrical Balance Ladder Test
  • 9. QUALITY CONTROL QUALITY CONTROL 1. 2. 3. Raw Material Control. Process Control & Continuous on-line testing. Product Control. Shyam Cables maintains very high standards of product quality through a very strict and efficient quality control system mainly. RAW MATERIAL CONTROL All raw materials under go rigorous testing for the conformity and stability in the manufacturing process. A highly qualified and experienced group of Chemists ensure that no sub-standard material is used in processing of cables. PROCESS CONTROL Process is controlled and checked by a team of experts and any deviations from standard process in immediately checked and corrective action is taken. PRODUCT CONTROL 100% testing and checking is done for cables. So that they are capable of giving satisfactory services in actual use. Our engineers ensure the cable conform to the standards is specified and results are well within relevant values. Elastometric Insulated Cables for working voltage upto and insulating 1100 Volts as per IS9968 - Part - I/1988 “ISI Marked” and upto as per IS:9968 Part - II/81. The elastometric insulated cables for fixed wiring, flexible cables and flexible cords for electric power and lighting for operation at voltage upto an including 6.6 K.V. is manufactured as per the requirements specified in IS: 9968 (Part-II) 1981. The type of cables covered under this standard are as follows:1) For Fixed Wiring. a) Braided and Compounded/Varnished. b) Elastomeric sheathed (general purpose) c) Elastomeric with earth community conductor (ECC) 2) For Fixed Wiring. a) Braided and Varnished. b) Elastomeric sheathed (Heavy Duty) 3) For Flexible Cords. a) Braided. b) Elastomeric sheathed (general purpose) c) Unlinkable flexible cords. 8
  • 10. CURRENT RATINGS The current ratings in table 1 & 2 based on the normal conditions of installation as described below : 0 1. Maximum condr. Temperature 70 C 5. Thermal resistivity of soil 0 2. Ambient air temperature 40 C 6. Thermal resistivity of cable 0 3. Ground temperature 30 C 7. Max. short-circuit conductor temp. 4. Depth of laying (for cable 8. Max. Ambient Air Temperature laid directly in ground ) 75 cm (1.1 KV) 0 150 C cm/watt 0 650 C cm/watt 0 160 C 0 55 C Installation method and rating factors are given in tables 1 to 6. Table -1 Rating for variations in ground temperature for cables laid directly in ground and in ducts 0 Ground temperature C 15 20 25 30 35 40 45 50 55 1.17 Rating factor 1.12 1.06 1.0 0.94 0.87 0.79 0.70 0.80 Table -2 Rating factors for variation in amblent air temperature 0 Air temperature C 25 35 40 45 50 55 1.25 Rating factor 30 1.16 1.09 1.00 0.90 0.80 0.69 Table- 3 Rating factors of groups of twin and multicore cables laid directly in ground in horizontal formation No. of cables Rating factor for axial spacing Touching 15 cm 30 cm 45 cm 60 cm 2 cables 0.78 0.81 0.85 0.88 0.90 3 cables 0.68 0.71 0.77 0.81 0.83 4 cables 0.61 0.65 0.72 0.76 0.79 6 cables 0.53 0.58 0.66 0.71 0.78 8 cables 0.48 0.54 0.62 0.67 0.72 Table -4 Rating factors of groups of twin and multicore cables laid directly in ground in tier formation Rating factor for axial spacing No. of cables Touching 15 cm 30 cm 45 cm 60 cm 4 cables 0.60 0.67 0.73 0.76 0.78 6 cables 0.51 0.57 0.63 0.67 0.69 8 cables 0.45 0.51 0.57 0.59 0.61 Table -5 Rating factors for variation in depth of laying in ground Depth of laying Rating factor upto 25 sq. mm. 75 90 105 120 150 150& above 1.00 0.99 0.98 0.97 0.96 0.95 Table 6 Group-rating factors for cables installed in ground, separated by more than 7 cms. No of cables 2 3 4 5 6 Single core D.C cables & multicore power cables 1.0 0.90 0.80 0.75 0.70 0.65 Single core A.C. cables 9 1 1.0` 0.80 0.75 0.70 0.65 0.60
  • 11. PROCESS FLOW CHART FOR PVC CABLES 10
  • 12. QUALITY ASSURACE CHART FOR PVC CABLES 11
  • 13. QUALITY ASSURACE CHART FOR PVC CABLES 12
  • 14. QUALITY ASSURACE CHART FOR PVC CABLES 13
  • 15. QUALITY ASSURACE CHART FOR PVC CABLES 14
  • 16. POWER & CONTROL CABLE AS PER IS-1554 (PART-I) 1988 1.1 K.V Grade, Copper/Aluiminum Conductor, PVC/HR PVC Insulated core laid up and PVC Inner Sheath, G.I. Steel Wire/Strip armoured and Overall PVC/HR PVC/FRLS PVC sheathed Cable “ISI MARKED” Material : Copper conductors are of annealed high conductivity copper wires IS:8130/1984. Aluminium conductors are of aluminium wire complying to IS-8130-1984. complying to Insulation : It is of PVC compound conforming to the requirements of Type - A,B,C, of IS-5831-84 Inner Sheath : (Common Covering) a) Vulcanised or unvulcanised rubber b) Thermoplastic material c) Proofed or plastic tape Armoured : a) Galvanised round steel wire b) Galvanised steel strip Outer Sheath : The outer sheath is of PVC compund conforming to the requirements of Type ST-1, ST-2 of IS-5831-1970 Conductor : (Nominal Cross Sectional/Area in mm ) 2 Copper 1.5 2.5 to 6 10 and above Aluminium Solid/Stranded 1.5 2.5 to 10 6 and aboveStranded Solid Solid Stranded THE CABLES AMPACITY Standard Conditions of installation for which the current carrying capacity is given in the ensuing tables are : Conductor temperature Thermal resistivity of soil Thermal resistivity of PVC Ambient temperature Ground temperature Depth of laying cable 15 : : : : : : 70 C Maximum 150 C cm/w 650 C cm/w 40 C 30 C 75 cm in the ground 0 0 0 0 0
  • 17. UNARMOURED CONTROL CABLE IS : 1554 (Pt - I ) - 1988 A p p ro x . N et. W eig h t of C a b les K g /k m S ta n d a rd D eliv ery L en g th in M trs. 1 1 .8 185 1000 23 20 1 2 .3 190 1000 21 17 1 .8 1 3 .2 225 1000 21 17 0 .3 1 .8 1 4 .1 260 1000 16 14 0 .8 0 .3 1 .8 1 5 .1 295 1000 15 13 0 .8 0 .3 1 .8 1 5 .1 315 1000 14 13 1 0 x 1 .5 0 .8 0 .3 1 .8 1 8 .4 425 1000 13 11 1 2 x 1 .5 0 .8 0 .3 1 .8 1 8 .9 480 1000 12 10 1 4 x 1 .5 0 .8 0 .3 1 .8 1 9 .8 535 1000 11 10 1 6 x 1 .5 0 .8 0 .3 1 .8 2 0 .7 595 1000 11 9 1 9 x 1 .5 0 .8 0 .3 2 .0 2 2 .5 720 1000 10 9 2 4 x 1 .5 0 .8 0 .3 2 .0 2 5 .8 880 1000 9 8 2 7 x 1 .5 0 .8 0 .3 2 .0 2 6 .3 960 1000 9 8 3 0 x 1 .5 0 .8 0 .3 2 .0 2 7 .2 1040 1000 9 7 3 7 x 1 .5 0 .8 0 .3 2 .0 2 9 .1 1230 1000 8 7 2 x 2. 5 0 .9 0 .3 1 .8 1 3 .0 230 1000 32 27 3 x 2. 5 0 .9 0 .3 1 .8 1 3 .6 240 1000 27 24 4 x 2. 5 0 .9 0 .3 1 .8 1 4 .6 290 1000 27 24 5 x 2. 5 0 .9 0 .3 1 .8 1 5 .7 335 1000 23 19 6 x 2. 5 0 .9 0 .3 1 .8 1 6 .9 385 1000 21 18 7 x 2. 5 0 .9 0 .3 1 .8 1 6 .9 420 1000 20 17 10 x 2. 5 0 .9 0 .3 1 .8 2 0 .8 570 1000 18 15 12 x 2. 5 0 .9 0 .3 2 .0 2 2 .2 690 1000 17 14 14 x 2. 5 0 .9 0 .3 2 .0 2 3 .2 775 1000 16 13 16 x 2. 5 0 .9 0 .3 2 .0 2 4 .3 860 1000 15 13 19 x 2. 5 0 .9 0 .3 2 .0 2 5 .5 985 1000 14 12 24 x 2. 5 0 .9 0 .3 2 .0 2 9 .4 1215 1000 13 11 27 x 2. 5 0 .9 0 .3 2 .0 3 0 .0 1330 1000 12 10 30 x 2. 5 0 .9 0 .3 2 .0 3 1 .0 1450 1000 12 10 37 x 2. 5 0 .9 0 .3 2 .2 3 4 .1 1790 1000 11 9 N o. of C ro res & C ro ss S ectio n a l A rea N O x m m 2. T h ick n ess of PV C in su ta io n (N o m .) T h ick n ess of PV C In n ersh ea th (M in ) T h ik n ess o f PV C o u tersh ea th (N o m .) mm mm mm 2 x 1 .5 0 .8 0 .3 1 .8 3 x 1 .5 0 .8 0 .3 1 .8 4 x 1 .5 0 .8 0 .3 5 x 1 .5 0 .8 6 x 1 .5 7 x 1 .5 A p p ro x . O .D . mm C u rren t R a tin g D irect in In G ro u u n d A ir/D u ct A m p s. A m p s. Construction 1. Solid/ Stranded annealed copper conductor & Tinned / Bare 2. General Purpose /HR PVC insulation 3. Cores laid up (filled if needed ) 4. FRLS / General Purpose PVC inner Sheath 5. FRLS / General Purpose PVC Outer sheath Max Conductor D.C Resistance at 20 Deg C – Conductor Size: 1.5 sq mm -12.1 Ohm /km (Bare, 12.2 Q/km (Tinned) 2.5 sq mm -7.41 Ohm /km (Bare, 7.56 Q/km (Tinned) *Dimensions specified are with stranded conductor 16
  • 18. 1 CORE ALUMINIUM PVC ARMOURED POWER CABLES Type No. of cores &Cross Section al Area Min no. of Wires Thickness of PVC insulation (nom) Nominal Dimension s of Armour Wire (mm) Mm Min Thickness of PVC Outer Sheath Overall Deamte r (Approx ) (mm) Approx Net Wt of cable Max.D. C Resista nce at 70 Max AC Resista nce at 70 Ohms/k m 8.8900 0.158 0.47 (Kg/Km) Approx Reactance at 50Hz Approx. Capacit ance Km 160 Ohms /km 7.4100 Km Ayway 1 1.30 1.40 1.24 Ayway 1Cx6 1 1.30 1.40 1.24 12 180 4.6100 5.5300 0.148 0.56 Ayway 1Cx10 1 1.30 1.40 1.24 13 210 3.0800 3.7000 0.138 0.67 Ayway 1Cx16 6 1.30 1.40 1.24 14 240 1.9100 2.2900 0.128 0.81 Ayway 1Cx25 6 1.50 1.40 1.24 15 310 1.2000 1.4400 0.120 0.87 Ayway 1Cx35 6 1.50 1.40 1.24 16 360 0.8680 1.0400 0.114 1.00 Ayway 1Cx50 6 1.70 1.40 1.24 18 450 0.6410 0.7700 0.110 1.03 Ayway 1Cx70 12 1.70 1.40 1.40 20 560 0.4430 0.5300 0.103 1.21 Ayway 1Cx95 15 1.90 1.60 1.40 22 720 0.3200 0.3800 0.101 1.27 Ayway 1Cx120 15 1.90 1.60 1.40 24 830 0.2530 0.3000 0.096 1.42 Ayway 1Cx150 15 2.10 1.60 1.40 27 980 0.2060 0.2500 0.094 1.42 Ayway 1Cx185 30 2.30 1.60 1.40 28 1160 0.1640 0.2000 0.092 1.44 Ayway 1Cx240 30 2.50 1.60 1.56 31 1450 0.1250 0.1500 0.090 1.53 Ayway 1Cx300 30 2.70 2.00 1.56 35 1710 0.1000 0.1200 0.088 1.56 Ayway 1Cx400 53 3.00 2.00 1.56 39 2190 0.0778 0.0934 0.088 1.56 Ayway 1Cx500 53 3.40 2.00 1.72 40 2730 0.0605 0.0726 0.087 1.57 Ayway 1Cx630 53 3.90 2.00 1.88 48 3440 0.0469 0.0563 0.086 1.57 Ayway 1Cx800 53 3.90 2.00 1.88 52 4120 0.0367 0.0440 0.083 1.75 Ayway 17 1Cx4 (mm) 11 1Cx1000 53 3.90 2.50 2.04 57 5090 0.0291 0.0349 0.082 1.94
  • 19. 1 CORE ALUMINIUM PVC UNARMOURED POWER CABLES Type No. of cores &Cross Sectional Area Min no. of Wires Thickness of insulation (nom) Nom. Thickness of Outer Sheath Overall Diameter (Appro) Net Wt of cable (approx) Max.D.C Resistan ce at 0 20 C Max AC Resistance 0 at 90 C Approx Reactanc e at 50Hz Approx. Capacita nce Mm (mm) (mm) (Kg/Km) Ohms /km Ohms/km Km Km Ayy 1CX4 1 1.00 1.80 8 100 7.4100 8.8900 0.137 0.58 Ayy 1CX6 1 1.00 1.80 9 110 4.6100 5.5300 0.127 0.68 Ayy 1CX10 1 1.00 1.80 10 130 3.0800 3.7000 0.118 0.83 Ayy 1CX16 6 1.00 1.80 11 160 1.9100 2.2900 0.110 1.01 Ayy 1CX25 6 1.20 1.80 12 220 1.2000 1.4400 0.105 1.05 Ayy 1CX35 6 1.20 1.80 13 260 0.8680 1.0400 0.100 0.22 Ayy 1CX50 6 1.40 1.80 15 330 0.6410 0.7700 0.098 1.22 Ayy 1CX70 12 1.40 1.80 17 410 0.4430 0.5300 0.091 0.43 Ayy 1CX95 15 1.60 1.80 19 530 0.3200 0.3800 0.088 1.47 Ayy 1CX120 15 1.60 2.00 21 640 0.2530 0.3000 0.086 1.62 Ayy 1CX150 15 1.80 2.00 23 770 0.2060 0.2500 0.085 1.62 Ayy 1CX185 30 2.00 2.00 25 920 0.1640 0.2000 0.084 1.62 Ayy 1CX240 30 2.20 2.00 28 1160 0.1250 0.1500 0.082 1.72 Ayy 1CX300 30 2.40 2.00 30 1390 0.1000 0.1200 0.080 1.74 Ayy 1CX400 53 2.60 2.20 35 1760 0.0778 0.0934 0.080 1.81 Ayy 1CX500 53 3.00 2.20 39 2200 0.0605 0.0726 0.079 1.76 Ayy 1CX630 53 3.40 2.40 44 2620 0.0469 0.0563 0.077 1.77 Ayy 1CX800 53 3.40 2.40 48 3430 0.0367 0.0440 0.077 1.98 Ayy 1CX1000 53 3.40 2.60 53 4180 0.0291 0.0349 0.076 2.20 18
  • 20. 2 CORE ALUMINIUM PVC ARMOURED POWER CABLES Type No. of cross & Cross Sectional Area Min no. of Wires Thickne ss of PVC insulati on (nom) Mm Min Thic knes s of PVC Oute r She ath( mm) Nominal Dimension of Armour Strip Wire (mm) Min. Thickness OF pvc outer strength Strip Wire Armour Armour Overall Diameter (approx) Strip Wire Armour Armour Appox Net Wt. of cable Strip wire Armour (mm) Max.D. C Resista nce at 20 Max AC Resist ance at 70 Approx Reacta nce at 50Hz (mm) Approx. Capacit ance Km Km (Kg/Km) Ohms /km Ohms /km Aywy 1 0.8 0.3 - 1.40 - 1.24 - 13.5 - 390 18.10 21.72 0.126 0.14 Aywy 2CX2.5 1 0.9 0.3 - 1.40 - 1.24 - 15.0 - 450 12.10 14.52 0.119 0.15 Aywy 2CX4 1 1.0 0.3 - 1.40 - 1.24 - 16.5 - 550 7.41 8.89 0.116 0.16 Aywy 2CX6 1 1.0 0.3 - 1.40 - 1.24 - 17.5 - 640 4.61 5.53 0.110 0.19 Aywy 2CX10 1 1.0 0.3 - 1.40 - 1.24 - 19.0 - 745 4.08 3.70 0.100 0.22 Aywy/ Ayfy 2CX16 6 1.0 0.3 4X0.8 1.60 1.40 1.40 20.5 22.5 565 830 1.91 2.29 0.097 0.29 Aywy/ Ayfy 2CX25 6 1.2 0.3 4X0.8 1.60 1.40 1.40 21.0 23.0 700 905 1.20 1.44 0.097 0.32 Aywy/ Ayfy 2CX35 6 1.2 0.3 4X0.8 1.60 1.40 1.40 22.5 24.0 810 1040 0.868 1.04 0.097 0.37 Aywy/ Ayfy 2CX50 6 1.4 0.3 4X0.8 1.60 1.40 1.56 25.0 27.0 1000 1290 0.641 0.77 0.094 0.37 Aywy/ Ayfy 2CX70 12 1.4 0.3 4X0.8 1.60 1.56 1.56 28.0 29.5 1230 1510 0.443 0.53 0.090 0.44 Aywy/ Ayfy 2CX95 15 1.6 0.4 4X0.8 2.00 1.56 1.56 31.5 34.0 1520 2060 0.320 0.38 0.090 0.44 Aywy/ Ayfy 2CX120 15 1.6 0.4 4X0.8 2.00 1.56 1.72 33.5 36.5 1765 2360 0.253 0.30 0.087 0.49 Aywy/ Ayfy 2CX150 15 1.8 0.4 4X0.8 2.00 1.72 1.72 37.0 39.5 2080 2700 0.206 0.25 0.087 0.49 Aywy/ Ayfy 2CX185 30 2.0 0.5 4X0.8 2.00 1.88 1.88 41.0 43.0 2500 3175 0.164 0.20 0.087 0.49 Aywy/ Ayfy 2CX240 30 2.2 0.5 4X0.8 2.50 2.04 2.04 45.5 49.0 3075 4230 0.125 0.15 0.087 0.50 Aywy/ Ayfy 2CX300 30 2.4 0.6 4X0.8 2.50 2.20 2.20 50.0 53.5 3760 4950 0.100 0.12 0.086 0.52 Aywy/ Ayfy 19 2CX1.5 2CX400 53 2.6 0.7 4X0.8 3.15 2.36 2.52 55.5 60.5 4560 6560 0.0778 0.09 0.086 0.53
  • 21. 3 CORE ALUMINIUM PVC ARMOURED POWER CABLES Type No. of cores &Cross Section al Area Min no. of Wires Thick ness of PVC insula tion (nom) (mm) Min Thi ckn ess of PV C Out er She ath( mm ) Nominal Dimension of Strip/Wire Armour Min. Thickness OF pvc outer strength Strip/ Wire Armour Overall Diameter (approx) Strip/Wire Armour Appox Net Wt. of cable Strip/wire Armour Max. D.C Resist ance at 20 Max AC Resi stan ce at 70 Approx Reactan ce at 50Hz Approx Capaci tance (mm) (mm) (mm) (Kg/Km) Ohms /km Ohm s/km Km Km Aywy 3Cx1.5 1 0.8 0.3 - 1.40 - 1.24 - 14.0 - 420 18.10 21.72 0.126 0.14 Aywy 3Cx2.5 1 0.9 0.3 - 1.40 - 1.24 - 15.0 - 500 12.10 14.52 0.119 0.15 Aywy 3Cx4 1 1.0 0.3 - 1.40 - 1.24 - 16.5 - 595 7.41 8.89 0.116 0.41 Aywy 3Cx6 1 1.0 0.3 - 1.40 - 1.24 - 17.5 - 685 4.61 5.53 0.110 0.47 Aywy 3Cx10 1 1.0 0.3 - 1.40 - 1.40 - 19.5 - 830 3.08 3.70 0.100 0.56 Aywy/ Ayfy 3Cx16 6 1.00 0.3 4x0.8 1.60 1.40 1.40 19.5 21.0 680 890 1.91 2.29 0.097 0.76 Aywy/ Ayfy 3Cx25 6 1.2 0.3 4x0.8 1.60 1.40 1.40 22.5 24.0 880 1120 1.20 1.44 0.097 0.86 Aywy/ Ayfy 3Cx35 6 1.2 0.3 4x0.8 1.60 1.40 1.40 24.0 25.5 1025 1305 0.868 1.04 0.097 0.98 Aywy/ Ayfy 3Cx50 6 1.40 0.3 4x0.8 1.60 1.56 1.56 27.5 29.0 1310 1605 0.641 0.77 0.094 1.02 Aywy 3Cx70 12 1.6 0.4 4x0.8 2.00 1.56 1.56 30.5 33.0 1630 2160 0.443 0.53 0.090 1.18 Aywy/ Ayfy 3Cx95 15 1.6 0.4 4x0.8 2.00 1.56 1.72 34.5 37.5 1990 2645 0.320 0.38 0.090 1.20 Aywy/ Ayfy 3Cx120 15 1.6 0.4 4x0.8 2.00 1.72 1.72 38.0 40.5 2375 3050 0.253 0.30 0.087 1.31 Aywy/ Ayfy 3Cx150 15 1.8 0.5 4x0.8 2.00 1.88 1.88 41.5 44.0 2825 3560 0.206 0.25 0.087 1.31 Aywy/ Ayfy 3Cx185 30 2.0 0.5 4x0.8 2.50 1.88 2.04 45.5 49.0 3365 4590 0.164 0.20 0.087 1.31 Aywy/ Ayfy 3Cx240 30 2.2 0.6 4x0.8 2.50 2.20 2.20 52.0 55.5 4250 5620 0.125 0.15 0.087 1.34 Aywy/ Ayfy 3Cx300 30 2.4 0.6 4x0.8 2.50 2.36 2.36 56.5 60.0 5140 6650 0.100 0.12 0.086 1.41 Aywy/ Ayfy 3Cx400 53 2.6 0.7 4x0.8 3.15 2.52 2.68 64.5 69.5 6270 8720 0.0778 0.09 0.086 1.45 20
  • 22. 3.5 CORE ALUMINIUM PVC ARMOURED POWER CABLES Type No. of cores &Cross Sectional Area Min no. of Wires Thickne ss of PVC insulatio n (nom) Mm Mi n Thi ckn ess of PV C Ou ter Sh eat h( m m) Nominal Dimension of Armour Strip Wire Overall Diameter (approx) Strip Wire Armour Armour Appox Net Wt. of cable (mm) (mm) Min. Thickness OF pvc outer strength Strip Wire Armour Armour (Kg/Km) Strip wire Armour Max.D .C Resist ance at 20 Max AC Resist ance at 70 Appro x React ance at 50Hz Ohms/ km Approx . Capaci tance Km (mm) Km Ohms /km Aywy/ Ayfy 6/6 1.2/1.0 0.3 4x0.8 1.60 1.40 1.40 25.0 26.5 1000 1260 1.2000 1.44 0.097 0.86 Aywy/ Ayfy 3.5Cx 35/16 6/6 1.2/1.0 0.3 4x0.8 1.60 1.40 1.40 26.0 27.5 1170 1450 0.8680 1.04 0.097 0.98 Aywy/ Ayfy 3.5Cx 50/25 6/6 1.4/120 0.3 4x0.8 1.60 1.56 1.56 29.5 31.0 1470 1805 0.6410 0.77 0.094 1.02 Aywy/ Ayfy 3.5Cx 70/35 12/6 1.4/1.2 0.4 4x0.8 2.00 1.56 1.56 33.5 36.0 1810 2405 0.4430 0.53 0.090 1.18 Aywy/ Ayfy 3.5Cx 95/50 15/6 1.6/1.4 0.4 4x0.8 2.00 1.56 1.72 37.5 40.0 2305 3015 0.3200 0.38 0.090 1.20 Aywy/ Ayfy 3.5Cx 120/70 15/12 1.6/1.4 0.5 4x0.8 2.00 1.72 1.88 41.0 43.0 2760 3545 0.2530 0.30 0.087 1.31 Aywy/ Ayfy 3.5Cx 150/70 15/12 1.8/1.4 0.5 4x0.8 2.00 1.88 1.88 45.5 48.0 3215 4030 0.2060 0.25 0.087 1.31 Aywy/ Ayfy 3.5Cx 185/95 30/15 2.0/1.6 0.5 4x0.8 2.50 2.04 2.04 50.0 53.5 3900 5300 0.1640 0.20 0.087 1.31 Aywy/ Ayfy 3.5Cx 240/120 30/15 2.2/1.6 0.6 4x0.8 2.50 2.20 2.36 57.0 60.0 4840 6390 0.1250 0.15 0.087 1.34 Aywy/ Ayfy 3.5Cx 300/150 30/15 2.4/1.8 0.6 4x0.8 3.15 2.36 2.52 61.5 66.0 5835 8210 0.1000 0.12 0.086 1.41 Aywy/ Ayfy 21 3.5Cx 25/16 3.5Cx 400/185 53/30 2.6/2.0 0.7 4x0.8 3.15 2.68 2.68 70.0 75.0 7250 9900 0.0778 0.09 0.086 1.45
  • 23. 4 CORE ALUMINIUM PVC ARMOURED POWER CABLES T ype No. o f c ores & Cros s Sec tion al A rea Min no. of W ir es T hick ne s s of P VC ins ulatio n ( nom) Mm Min T hi c kn es s of PV C O ut er S he a th( mm ) Nom ina l Dim ension of A rm our Strip /W ire Min. Thic kness O F pvc o uter strength Strip/W ire Ar mour O vera ll Diam eter (approx) Strip/ W ire A rm our Appo x Net W t. of cable (m m ) (m m) ( mm ) (K g/K m) S trip /wir e Arm our M ax.D. C Res is t ance at 20 M ax AC Resi s tan ce at 70 Ap pro x R eact anc e at 50Hz A ppr ox . Capa c itan ce Ohm s /km O hm s/km Km Km A yw y 4CX 1 .5 1 0.8 0 .3 - 1.40 - 1.24 - 14 .5 - 470 18 .100 0 21 .72 0.126 0.14 A yw y 4CX 2 .5 1 0.9 0 .3 - 1.40 - 1.24 - 16 .0 - 560 12 .100 0 14 .52 0.119 0.15 A yw y 4C X 4 1 1.0 0 .3 - 1.40 - 1.24 - 17 .5 - 675 7.4100 8.89 0.116 0.41 1 1.0 0 .3 - 1.40 - 1.24 - 19 .0 - 800 4.6100 5.53 0.110 0.47 1 1.0 0 .3 4x0.8 1.60 1.40 14 0 21.5 23 .0 80 0 1 030 3.0800 3.70 0.100 0.56 6 1.0 0 .3 4x0.8 1.60 1.40 1.40 23.0 25 .0 83 0 1 050 1.9100 2.29 0.097 0.76 6 1.2 0 .3 4x0.8 1.60 1.40 1.40 25.0 27 .0 1075 1 350 1.2000 1.44 0.097 0.86 6 1.2 0 .3 4x0.8 1.60 1.40 1.40 27.5 30 .0 1280 1 620 0.8680 1.04 0.097 0.98 6 1.4 0 .4 4x0.8 2.00 1.56 1.56 32.0 34 .5 1620 2 175 0.6410 0.77 0.094 1.02 12 1.4 0 .4 4x0.8 2.00 1.56 1.56 36.5 38 .0 2010 2 660 0.4430 0.53 0.090 1.18 A yw y 4C X 6 A yw y /A yfy 4CX 10 A yw y /A yfy 4CX 16 A yw y /A yfy 4CX 25 A yw y /A yfy 4CX 35 A yw y /A yfy 4CX 50 A yw y /A yfy 4CX 70 A yw y /A yfy 4CX 95 15 1.6 0 .4 4x0.8 2.00 1.72 17 2 40.0 42 .5 2550 3 280 0.3200 0.38 0.090 1.20 A yw y /A yfy 4C X 120 15 1.6 0 .5 4x0.8 2.00 1.88 1.88 44.5 47 .0 3040 3 840 0.2530 0.30 0.087 1.31 A yw y /A yfy 4C X 150 15 1.8 0 .5 4x0.8 2.50 1.88 2.04 48.0 51 .0 3580 4 880 0.2060 0.25 0.087 1.31 A yw y /A yfy 4C X 185 30 2.0 0 .6 4x0.8 2.50 2.04 2.20 53.0 57 .0 4340 5 810 0.1640 0.20 0.087 1.31 A yw y /A yfy 4C X 240 30 2.2 0 .6 4x0.8 2.50 2.36 2.36 60.0 64 .0 5460 7 050 0.1250 0.15 0.087 1.34 A yw y /A yfy 4C X 300 30 2.4 0 .7 4x0.8 3.15 2.52 2.68 60.5 71 .0 6630 9 260 0.1000 0.12 0.086 1.41 A yw y /A yfy 4C X 400 53 2.6 0 .7 4x0.8 3.15 2.84 2.84 73.0 78 .0 8185 11020 0.0778 0.09 0.086 1.45 22
  • 24. ARMOURED CONTROL CABLE IS: 1554 (Pt-I) -1988 No. of Crores &Cross Sectional Area NO x mm 2. Thic kne ss of PVC Insu latio n (No m) mm Standa rd Deliver y Length in Mtrs. Thick ness of Inners heath (min) Extru ded mm STRIP ARMOURED CABLE Strip Size Mm 2 x 1.5 3 x 1.5 4 x 1.5 5 x 1.5 6 x 1.5 7 x 1.5 10 x 1.5 12 x 1.5 14 x 1.5 16 x 1.5 19 x 1.5 24 x 1.5 27 x 1.5 30 x 1.5 37 x 1.5 2 x 2.5 3 x 2.5 4 x 2.5 5 x 2.5 6 x 2.5 7 x 2.5 10 x 2.5 12 x 2.5 14 x 2.5 16 x 2.5 19 x 2.5 24 x 2.5 27 x 2.5 30 x 2.5 37 x 2.5 23 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.9 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.4 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 4x0.8 Thicknes s PVC Outer Sheath (Min) Mm Approx. OD 1.24 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.56 1.56 WIRE ARMOURED CABLE Approx. Net weight of cable Kg/km Roun d WireD ia 19.5 20.8 21.7 23.1 26.4 26.9 27.8 29.7 760 830 920 1040 1250 1355 1430 1670 21.8 22.8 23.8 24.9 26.1 30.0 30.6 32.0 34.7 900 1020 1130 1210 1355 1655 1770 1940 2300 1.4 1.4 1.4 1.4 1.4 1.4 1.4 1.8 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2.2 2.2 Mm Current Rating Thickness PVC Outer Sheath (Min) Mm Approx. OD 1.24 1.24 1.24 1.24 1.24 1.24 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.40 1.24 1.24 1.24 1.24 1.24 1.24 1.40 1.40 1.40 1.40 1.40 1.56 1.56 1.56 1.56 13.6 14.1 15.0 15.9 16.9 16.9 20.6 21.5 22.4 23.3 24.7 28.0 28.5 29.4 31.3 14.8 15.4 16.4 17.5 18.7 18.7 23.4 24.4 25.4 26.5 27.7 32.0 32.6 33.6 37.1 Mm Approx. New Weight of cable Kg/km Direct in Groun d mm In Air/ Duct. Amps Amps 415 430 490 545 604 630 835 950 1040 1130 1265 1510 1610 1700 1960 500 520 590 660 745 780 1110 1240 1340 1455 1605 1970 2100 2250 2900 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 1000 23 21 21 16 15 14 13 12 11 11 10 9 9 9 8 32 27 27 23 21 20 18 17 16 15 14 13 12 12 11 20 17 17 14 13 13 11 10 10 9 9 8 8 7 7 27 24 24 19 18 17 15 14 13 13 12 11 10 10 9
  • 25. PROCESS FLOW CHART FOR RUBBER CABLES 24
  • 26. QUALITY ASSURACE CHART FOR RUBBER CABLES 25
  • 27. QUALITY ASSURACE CHART FOR RUBBER CABLES 26
  • 28. TABLE- 3 1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR) INSULATED OVERALL PCP, CSP/TRS SHEATHED FLAT THREE CORE (WITHOUT ECC) CABLE “ISI MARKED” AS PER IS : 9968/Pt-1/1988 Nominal Cross Sectional Area Nominal of Insulation Thickness of Sheath Flat Flat Nominal cross Sectional Area of Earth mm2 mm Twin mm Three Continuity Conductor mm mm 1.0 1.5 2.5 4 6 10 16 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.0 1.0 1.10 1.20 1.20 1.3 1.4 1.0 1.1 1.1 1.2 1.2 1.4 1.4 of Conductor 2 2 1.0 1.5 1.5 1.5 2.5 4.0 6.0 TABLE- 2 1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR) INSULATED OVERALL PCP, CSP/TRS SHEATHED SINGLE-CORE CIRCULAR TWIN CORE THREE CORE THREE & FOUR CORE CABLE “ISI MARKED” AS PER IS: 9968/Pt-1/1988 Nominal Cross Sectional Area of Conductor mm 1 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 2 27 Thickness of Insulation Single Core Twin Core Three Core Four Core mm 1.0 1.0 1.0 1.0 1.0 1.20 1.20 1.40 1.40 1.6 1.6 1.8 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.0 mm 1.0 1.0 1.0 1.0 1.0 1.1 1.1 1.2 1.2 1.3 1.4 1.4 1.5 1.6 1.7 1.8 1.90 2.0 2.2 2.3 mm 1.0 1.0 1.1 1.20 1.2 1.3 1.4 1.5 1.6 1.8 1.9 2.1 2.2 2.4 2.6 2.8 3.0 3.2 - mm 1.0 1.1 1.1 1.2 1.2 1.4 1.4 1.6 1.7 1.8 2.0 2.2 2.3 2.5 2.7 3.0 3.2 3.4 - mm 1.1 1.1 1.1 1.2 1.3 1.4 1.5 1.7 1.7 2.0 2.1 2.4 2.5 2.7 2.9 3.2 3.5 3.8 -
  • 29. TABLE-4 1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR)/SILICON INSULATED OVERALL PCP, CSP/TRS SHEATHED CABLE SINGLE TWIN, THREE AND FOUR-CORE GLASS FIBRE BRAIDED AND VARNISHED CABLES AND CORDS “ISI MAREKED” AS PER IS: 9968/Pt1/1988 Nominal Cross-Sectional Area of Conductor mm2 0.50 0.75 1 1.5 2.5 4 6 10 16 25 35 50 Thickness of Insulation Cables for Fixed Flexible cables or Wiring Cords mm mm 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.6 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.2 1.2 1.2 1.4 1.6 TABLE-5 1100 V GRADE, FLEXIBLE ATC CONDUCTOR, ELASTOMERIC (EPR/VIR)/SILICON INSULATED OVERALL PCP, CSP/TRS SHEATHED CABLE SINGLE-CORE, CIRCULAR TWIN, THREE-CORE, FOUR-CORE AND FIVE CORE “ISI MARKED” AS PER IS: 9968/Pt-1/1988 Nominal Cross Sectional Area of Conductor Thickness of Insulation (ft) Single Core Thickness of Sheath (ts) Twin Three Four Core Core Core Five Core 6 16 10 25 35 50 70 95 120 150 185 240 300 1.0 1.2 1.2 1.20 1.4 1.60 1.6 1.80 1.8 2.0 2.2 2.4 2.6 1.6 1.9 1.8 2.0 2.2 2.4 2.6 2.8 3.0 3.2 3.4 3.5 3.6 2.0 2.5 2.4 3.2 3.3 3.5 3.6 3.8 4.0 4.2 4.3 4.6 4.9 2.50 3.2 2.9 - 2.1 2.7 2.5 3.3 3.4 3.6 3.7 4.0 4.1 4.3 4.5 4.8 5.1 2.50 2.9 2.7 3.4 3.5 3.7 3.9 4.1 4.3 4.5 4.8 5.1 5.4 28
  • 30. WELDING CABLES COPPER/ALUMINIUM WELDING CABLES WITH HOFR COVERING/GENERAL PURPOSE ELECTROMETRIC SHEATHED AS PER IS-9857/1990 “ISI MARKED” The welding cable is suitable for use where combination of ambient temperature and temperature rise due to load results a conductor temperature not exceeding 60 °C for general purpose rubber copound cables and 85°C for general purpose HOFR compound cables. (Heat resisting, oil resisting and flame retardant). Copper Conductor Copper Conductor is of annealed high conductivity copper wire complying to IS-8130-1984. Aluminium Conductor Aluminium Conductor is of Aluminium wire complying to IS-8130-1976. Nominal Area of Conductor mm 16* 25 35 50 70 95 120** 2 TABLE-1 THICKNESS OF COVERING Redial Thickness of Covering (tc) mm 2.00 2.00 2.00 2.20 2.40 2.60 2.80 * For copper conductor only ** For aluminium conductor only 29
  • 31. TABLE-2 CURRENT RATINGS OF GENERAL PURPOSE RUBBER COMPOUND COVERED CABLE WITH COPPER CONDUCTIOR Nominal Area of Conductor 100% mm 2 16 25 35 50 70 95 Current Rating as a maximum duly cycle of 85% 60% 30% 20% A A A A A 94 125 156 197 248 299 102 136 169 214 269 342 121 161 201 254 320 386 172 228 285 360 453 546 210 279 349 440 555 669 Ambient Air Temperature = 30oc Maximum Conductor temperature = 60oc TABLE - 3 CURRENT RATINGS OF GENERAL PURPOSE HOFR COMPOUND COVERED CABLES WITH COPPER CONDUCTOR Nominal Area of Conductor mm 16 25 35 50 70 95 2 Current Rating at a Maximum duly cycle of 100% 85% 60% 30% A A A 135 177 221 279 352 424 146 192 240 303 382 460 174 228 285 360 454 547 Ambient Air Temperature = 30oc A 246 343 403 509 643 774 Maximum Conductor temperature = 90oc 30
  • 32. TABLE -4 CURRENT RATING OF GENERAL PURPOSE RUBBER COMPOUND COVERED CABLE WITH ALUMINIUM CONDUCTOR Nominal Area of Conductor mm 2 25 35 50 70 95 120 Current Rating as a maximum duly cycle of 100% 85% 60% 30% 20% A A A A A 100 123 155 196 237 283 108 133 168 213 257 307 129 159 200 253 306 365 183 225 283 358 433 517 224 275 347 438 530 633 Ambient Air Temperature = 30oc Maximum Conductor temperature = 60oc TABLE- 5 CURRENT RATINGS OF GENERAL PURPOSE HOFR COMPOUND COVERED CABLE WITH ALUMINIUM CONDUCTOR Nominal Area of Conductor Current Rating as a maximum duly cycle of 100% 85% 60% 30% 2 mm 25 35 50 70 95 120 Ambient Air Temperature = 30oc 31 A 144 176 222 280 339 404 A 156 191 241 304 368 438 A 186 227 287 361 438 522 A 263 321 405 511 619 738 Maximum Conductor temperature = 60oc
  • 33. TABLE - 6 VOLTAGE DROP IN COPPER CONDUCTORS AT NORMAL AND ELEVATED TEMPERATURES Nominal Area of Conductor DV Voltage Drop/100/A1/210 m of Cable at 20 C 60 C 90 C mm V V V 16 1.19 1.438 1.587 25 0.780 0.922 1.018 35 0.552 0.655 0.773 50 0.390 0.456 0.503 70 0.276 0.321 0.355 95 0.244 0.244 0.269 2 0 0 0 TABLE - 7 VOLTAGE DROP IN ALUMINIUM CONDUCTORS AT NORMAL AND ELEVATED TEMPERATURES Nominal Area DC Voltage Drop/100A/10 m of Cable at Sectional Area of Conductor 20 C 60 C 90 C mm V V V 25 1.23 1.427 1.574 35 0.901 1.045 1.153 50 0.634 0.735 0.811 70 0.445 0.516 0.570 95 0.334 0.387 0.428 120 0.256 0.297 0.328 2 0 0 0 32
  • 34. Table 3 STRANDED COPPER AND ALUMINIUM CONDUCTORS (WEIGHT & DC RESISTANCE AT 200C ) Nominal Area of Conductor (sq. mm) 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 33 Annealed plain Copper Appox. Weight Max.d.c.resist0 (kgkm) ance at 20 C (ohms/km) 9.0 13.3 22.4 36.1 54.0 90.8 145 229 317 429 620 860 1086 1334 1673 2199 2759 3528 4445 5744 18.1 12.1 7.41 4.61 3.08 1.83 1.15 0.727 0.524 0.387 0.268 0.193 0.153 0.124 0.0991 0.0754 0.0601 0.0470 0.0366 0.0283 Approx. (kgkm) 2.70 4.1 6.8 10.4 16.4 27.7 43.9 69.5 96.4 131 189 262 331 406 409 669 839 1073 1353 1746 Aluminium Max.d.c.resist0 ance at 20 C (ohms/km) 29.9 18.1 12.1 7.41 4.61 3.08 1.91 1.20 0.868 0.641 0.443 0.320 0.253 0.206 0.164 0.125 0.100 0.0778 0.0605 0.0469
  • 35. TABLE -4 FLEXIBLE COPPER CONDUCTORS Nominal Area of Conductor (sq. mm) Approx. Weight (kgkm 1.0 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 9.5 14.0 23.5 37.9 56.7 95.3 152 240 333 450 651 903 1140 1401 1757 2309 2897 3704 4670 6031 Max. D.C.resistance at 200C (ohms/km) Annealed plain Copper Annealed tinned Cooper 19.5 13.3 7.98 4.95 3.30 1.91 1.21 0.780 0.554 0.386 0.272 0.206 0.161 0.129 0.106 0.0801 0.0641 0.0486 0.0384 0.0287 20.0 13.7 8.21 5.09 3.39 1.95 1.24 0.795 0.565 0.393 0.277 0.210 0.164 0.132 0.108 0.0817 0.0654 0.0495 0.0391 0.0292 34
  • 36. TABLE -5 TEMPERATURE CORRECTION FACTORE FOR CONDUCTOR RESISTANCE AT DIFFERENT TEMPERATURES 0 Temperature( C) 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 35 Temperature correction factor for Copper and Aluminium conductor 0.94 0.96 0.98 1.00 1.02 1.04 1.06 1.08 1.10 1.12 1.14 1.16 1.18 1.20 1.22 1.24 1.26 1.28
  • 37. VOLTAGE DROP CALCULATIONS An approximate check can be made on voltage drop by means of the following formulae: For d.c. and single phase a.c. two wire system: = 2xIxLxRxt 1000 For three phase a.c. system : = 1.732 x I x L x R x t 1000 Where I = Current in Amperes. L = Length of cable run in metres (one conductor only). R = Resistance in ohms of one conductor only from table 3-4. T = temperature correction factor from table 5. Notes: 1) Resistance values for copper and aluminium conductors are shown in table 3 and 4. 2). for conductor cross section above 70sqmm an allowance must be considered for skin and proximity effect. USEFUL 3 PHASE FORMULA KW = KVA x power factor KW = HP x 746 1000 x efficiency Line Amps x Line Volts x 1.732 x power factor 1000 = HP = Line Amps x Line Volts x 1.732 x efficiency x p.f. 746 36
  • 38. TABLE-8 PROPERTIES OF METALS USED IN CABLE - Annealed Copper 8.89 Tensile strength (Approx.) Kg/mm2 25 12 to 15 Melting point Deg. C 1083 659 % 23 to 40 2 to 6 15 30 7000 19000 1600 Properties Unit Specific gravity Elongation Young’s Modules of Elasticity Kg/mm2 Co-efficient of linear expansion Deg. C Specific heat K cal/kg0C Thermal resistivity 0 103 9 to 15.5 Aluminium Steel Lead 2.703 7.86 11.37 30 to 50 1.8 1400 327 0.217 0.114 C cm/watt 0.25 0.48 2.20 2.96 Specific electrical resistance at 200C Microhm/cm 1.7241 2.8264 1405 21.0 Temp. co-efficiect of resistance at 20oC 37 0.093 29 10-6 0.031 Per deg.C 0.00393 0.00403 0.0042 0.0042 17 10-6 23 10-6 11.5 10-6
  • 39. TABLE 9 PERFORMANCE AND SELECTION OF COMMONLY USED THERMOPLASTIC CABLES INSULATING AND SHEATHING MATERIALS General purpose PVC insulation ty pe A to IS5831/84 Material General purpose PVC insulation ty pe B to IS5831/84 Heat resisting PVC insulation ty pe C to IS5831/84 Max. cond. Tem. For 0 continous operation ( C) General purpose PVC sheath ty pe ST 1 to IS5831/84 70 Heat resisting PVC sheath ty pe ST 2 to IS-5831/84 Low Temp. PVC Special Heat resistin g PVC 105 Poly tertre f luro ethy lene (PTFE) Fluorinated ethy len e propy le ne (FEP) 70 260 200 Poly ethy lene 90 70 160 160 160 160 130 500 250 -20 -15 -40 -30 -60 -75 -75 E E E E E E G G E E E E E E P P P G G G G G G G P E E Oil G G G G G G G F E E Water G E G G G G G G E E Chemical G G G G G G G G E E Solv ents F F F F F F F G E E Abrasions G E E G E G E E E E 70 70 85 160 160 160 -20 -15 -15 E E Coronaz E Weather Max. cond. Temp . at the termination of 0 shorty circuit ( C) 0 Min. working temp. ( C) Resistance to Ozone Flame resistance Electricals E E E E E E E P E E Insulation resistance G E E NA NA G E E E E Voltage breakdown G G G NA NA G G E E E A.C.Losses F F F NA NA F F E E E E- EXCELLENT : G- GOOD: F –FAIR: P- POOR: NA- NOT APPLICABLE 38
  • 40. TABLE 10 PERFOMANCE AND SELECTION OF COMMONLY USED ELASTOMERIC CABLES INSULATING AND SHEATHING MATERIALS Natureal Rubber (VIR &TRS)in cluding blends with SBR M aterial Max. cond. Tem. For continous operation (0 C) Heat Resist-ing Natural rubber HRVIR Ethylene propylen e rubber EPR Polychlo roprene rubber PCP 90 Nitrile Butadiene rubber blend with PVC (NBRPVC) Chlorosulp h-onated polyethylen e rubber CSP Cross linked Polyethy lene (XLPE) 90 Silicon rubber 150/180 90 90 200 200 200 250 350 -50 -40 -30 -35 -40 -55 P E G G E G E P P E NA NA G P G Weather P F G E G E G E Oil P P P G E G G P/F Water G G G F G G G G Chemical F F G F F G G F Solvents P P P G G G G G Abrasions Flame resistance Electrical Insulation resistance F F P G G G G P/F P P P E G E P E G G G NA NA F E F Vo ltage breakdown G G G NA NA G E G A.C.Losses G G G NA NA F E G 60 75 200 200 -55 -55 P Corona Max. cond. Temp . at the termination of shortly circuit (0 C) Min. working temp. (0 C) Resistance to Ozone 90 250 E- EXCELLENT : G- GOOD: F –FAIR: P- POOR: NA- NOT APPLICABLE 39
  • 41. TELEPHONE CABLES 1. Telephone Switch Bard Multicore Cables are being extensively used by Telephone Depart ment, Govt.Departments, railway and other industries in their telecommunication network. 2. Conductor : Annealed tinned-electrolytic copper conductors, PVC colour coded as per ITO Specification D-3003 ITD-S/WS-1138 or S/WS-1148 each wire twisted with its mate wire in a right hand lay and each such pair twisted with its make wire in a right hand lay and each such pair twisted with respect to all other airs in concentric layers so as to supress cress talk. The conductors shall be 0.5, 0.6, 0.7 or 0. 9 mm Dia. and Cables are manufactured in one pair size to 100 pairs as per costomers requirements. 3. Insulation : Hard Grade PVC with nominal radial thickness. 4. Colour Scheme : As per I.T.I.D. 3003,ITD S/WS-113B OF S/WB-114B. 5. Armouring : The armouring shall consist of galvanised steel wires having nominal diameter of 1.4 mm for Cables having inner sheathed diameter uto 13mm in Cables where the diameter of inner sheathing exceeds 13 mm, steel striof size 4 x 0.8 mm is to be used. 6. Sheathing : The outer sheath shall be extruded PVC Compound specially designed to afford high degree of mechanical chemical and Thermal Properties. RECOMMENDATIONS FOR INSTALLATION The following are some of the salient factors which should be kept in view during installation of PVC Insulated Heavy Duty Cables : 1. Before laying, the insulation of the cable should be checked with megger as a preliminary check against any probably damage. 2. The drum should be always rolled in the "direction of arrow for rolling" marked on the drum. In the absence of any such mark, the drum should be rolled in the direction same as that of inside and of the cable and opposite to that of the outside end. 3. Where the cable is to be jointed with existing cable, the sequence of cores at the two ends to be jointed should be in the opposite direction i.e. If at one end it is in clockwise direction, at the other end it should be in anticlockwise direction. This is necessary to avoid the crossing of cores while jointing. This will also decide the direction in which the cable is to be pulled. 4. Wherever possible bending radius of 12 times the overall diameter of the cable should be maintained, but in any case it should not be less than 8 times. 40
  • 42. 5. 6. 7. Where the cables are necessarily laid and jointed in very cold regions both the cable and the ambient temperature should be above OC and have remained so for the previous 24 hours. During such conditions, the cable should also not be bent to ver small radius. A joint being the weakest point of the electric power transmission system, all necesaary precautions shuld be taken. Jointing materials and accessories like conductiors ferules, solder, insulating and protective tapes, protective filling compound, joint boxes etc. of right quality and sized should be procured. The application of these materials should be made skilfully for joining work. In this connection, it is always advisable that the method and the working instructions of the supplier should be strictly followed. Armoured Cables : All bonding clamps at the joints and terminations and the armour wires should be thoroughly cleaned. The clamps should be adequately tightened. This is necessary to ensure proper electrical contact, because armour is the only return path for earth fault current. Unarmoured Cables : In case of unarmoured cables, the external metallic earth bodding connector of adequate sizes should be used. 8. Earth : All joints, terminations, armour wires and external metallic bonding should be connected to earth. Wherever possible, armour at one end of the cable should be connected to main earth system at the supplying end by employing metallic connectors. Precautions should be taken to eliminate the chemical and bimetallic corrosion of the earth connectors or bonds. 9. Filling Compunds : a) The design of the box and the cimposition of the filling compound should provide an effective saving against entry of moisture to conductor ferrules and a hour connector. b) If not pouring protective compounds, are used, the temperatures of the compound whicl pouring should not exceed 100 C. 0 10. Test after installion : After the cable is installed, a voltage test may be carried out. Each core should be tested at 4KV against others and the armour, the latters connected to the earth. The voltage should be injcreased gradually to full value and maintained continuously for 15 minutes. No breakdown of insulation occur during the test. 41
  • 43. 42
  • 44. 43
  • 45. 44
  • 46. 45
  • 47. 46
  • 48. 47
  • 49. 48
  • 50. 49
  • 51. 50
  • 52. 51
  • 53. 52
  • 54. 53
  • 55. 54
  • 56. 55
  • 57. 56
  • 58. 57
  • 59. 58
  • 60. 59
  • 61. 60