We offer Microprocessor Based Turbidity Meter – (VSI-702) which is designed to provide the precise Turbidity & Temperature measurements in the samples. The instrument uses the latest Microprocessor technology and advanced engineering techniques so as to give enhanced accuracy and reproducibility. The instrument has user friendly prompts which guide you throughout the measurement process. It has Auto Ranging facility in Turbidity Parameter.
FEATURES OF MICROPROCESSOR BASED TURBIDITY METER (VSI-702):
• 16 x 2 Lines Alphanumeric LCD Display
• Turbidity & Temperature Measurement Simultaneously
• Automatic Range Selection in Turbidity
• 1000 Samples Storage Facility
• Computer/Printer Attachment Facility
Beginners Guide to TikTok for Search - Rachel Pearson - We are Tilt __ Bright...
Catalog Microprocessor based Turbidity Meters VSI-702
1. Microprocessor Based Turbidity Meter
(Model : VSI-702)
FEATURES
16 x 2 Lines Alphanumeric LCD Display
Turbidity & Temperature Measurement Simultaneously
Automatic Range Selection in Turbidity
1000 Samples Storage Facility
Computer/Printer Attachment Facility
Microprocessor Based Turbidity Meter – (VSI-702) is designed to provide the precise Turbidity &
Temperature measurements in the samples. The instrument uses the latest Microprocessor
technology and advanced engineering techniques so as to give enhanced accuracy and
reproducibility. The instrument has user friendly prompts which guide you throughout the
measurement process. It has Auto Ranging facility in Turbidity Parameter.
The instrument has 6 soft touch membrane type keys with audible sound for ease of operation. It
has the data storage facility for 1000 samples, which are retained in the memory even when the
instrument is switched OFF. Provision has also been provided for attachment of centronix dot matrix
printer so that any of the stored results can be printed.
It is extremely useful for measurement of suspended solids/turbidity levels in Sewage Water, Ground
Water, Potable Water, Soil Analysis Laboratories, Fisheries, Water Quality Control in Boiler Feed
Water, Water Works Department, Breweries, Water Purification Plants, Chemical & Pharmaceutical
Industries, etc.
2. Microprocessor Based Turbidity Meter
(Model : VSI-702)
TECHNICAL SPECIFICATIONS :
Function Turbidity & Temperature Simultaneously
Display 16 Characters x 2 Lines Alphanumeric LCD
Power Supply 230 V ± 10%, 50 Hz AC
TURBIDITY MEASUREMENT
Range 0 – 1000 NTU in Two Ranges
Resolution 0.1 NTU in lowest Range
Accuracy ± 3% FS ± 1 Digit
Range Selection Automatic
Detector Photodiode/Photocell
Sample System 30 mm. Clear Glass Test Tube
Calibration Manual
Light Source 6 V Tungsten Lamp
Display Format Temperature & Turbidity Simultaneously
TEMPERATURE MEASUREMENT
Range -20˚C to +200˚C
Resolution 0.1 ˚C
Accuracy ± 0.1% of Range ±1 Digit
Calibration Two Point Manual
Sensor Pt-100 Probe
Data Entry By Six Soft Touch Keys with Audible Sound
Storage Memory 1000 Samples
Real time display 24 Hour Mode with Date
Interface RS-232,Centronics & Computer
Print Format All Data & Date Wise (Programmable)
Digital Output Serial RS-232 & Parallel Centronics
STANDARD ACCESSORIES : Temperature Probe, Test Tubes, Data Cable & Instruction Manual.
: PRINT FORMAT :
DATE TIME TEMP(oC) PARAMETER MODE Sample No.
(SP. No.)
05/07/10 10:20 T= 020.0 MANUL 001
05/07/10 10:21 T= 020.0 MANUL 002
05/07/10 10:22 T= 020.0 MANUL 003
Note: Appearance & Specifications are subject to change due to continuous development.