ISAM FD
General Test Plan
VDSL2, Vectoring
Alcatel-Lucent
Fixed Networks APAC
RBC Customer Engineering
Revision 1
22 April 2014
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 2 of 29]
LEGAL NOTICE
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other
trademarks are the property of their respective owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility
for inaccuracies contained herein.
Copyright © 2014 Alcatel-Lucent. All Rights Reserved.
This document contains proprietary/trade secret information which is the property of Alcatel-Lucent and
must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written
authorization.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 3 of 29]
Table of contents
1 CONFIGURA TION UNDER TEST .............................................................................................. 4
1.1 SUMMARY.............................................................................................................................4
1.2 SYSTEM UNDER TEST ...............................................................................................................4
1.3 TEST DIAGRAM ......................................................................................................................5
1.4 PREREQUISITES......................................................................................................................5
2 VECTORING TESTS .................................................................................................................. 6
2.1 SYSTEM SETUP AND PRE-TESTS...................................................................................................6
2.2 VECTORING PERFORMANCE........................................................................................................6
3 FUNCTION/FEA TURE TESTS ................................................................................................. 10
3.1 HSI SERVICE.......................................................................................................................10
3.2 MULTICAST SERVICE..............................................................................................................12
3.3 TRIPLE-PLAY SERVICE ............................................................................................................13
3.4 POTS VOICE (SIP) ..............................................................................................................15
4 SYSTEM ACCEPTA NCE ........................................................................................................... 17
4.1 FAN ALARM.......................................................................................................................17
4.2 POWER ALARM(A/B)..........................................................................................................19
4.3 SYNC RATE OF 48 VDSL PORTS...............................................................................................21
4.4 VOICE SERVICE ON 48 PORTS ..................................................................................................23
5 ISSUES ENCOUNTERED & OBSERVATIONS ......................................................................... 25
6 OFFICIAL ENDORSEMENT ..................................................................................................... 26
7 ANNEX A - CLI CONFIGURA TION OF PROPOSED PROFILES............................................... 27
7.1 SERVICE PROFILES ...........................................................................................................27
7.2 SPECTRUM PROFILES........................................................................................................27
7.3 VECTORING PROFILES ......................................................................................................28
7.4 VCE PROFILES ..................................................................................................................28
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 4 of 29]
1 CONFIGURATION UNDER TEST
1.1 Summary
This document contains test plan for VDSL2 vectoring based on Alcatel-Lucent Board Level Vectoring
Solution.
1.2 System under test
Procedures are verified with the following configuration:
Enclosure 7356 7360FX
NT Controller (software) NRNT-A(5.0.122) FANT-F (4.6.477)
ELT NDLT-C, 48L VDSL2 card with BLV
NPOT-C, 48 line POTs card
NVSP-B, 48 port POTS VDSL
Splitter
OLT NGLT-C, 8-GPON Line Termination
Board
Vectoring CPEs Sagemcom F@ST5310
ONT O-010S-P, SFP ONT
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 5 of 29]
1.3 Test Diagram
1.4 Prerequisites
1.4.1 Real cable
At least one real cable with multiple pairs, in order to have real crosstalk between various DSL lines.
Amount of pairs: 48 pairs is proposed for the field trial.
The cable should be representative of real cable in use in the customer’s distribution network. In
particular the binder structure of the cable should be representative of actual cables.
Length: preferably between 400 m - 500 m, maximum 1000 m (on longer cable lengths, vectoring gains
are lower)
Multiple cables or cable lengths can be tested if available.
1.4.2 VDSL profiles
ANNEX A - CLI CONFIGURATION OF PROPOSED PROFILES of this document contains ALU proposed
profiles to be used for the testing.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 6 of 29]
2 VECTORING TESTS
2.1 System setup and pre-tests
Set-up equipment in lab and connect to test cable.
Pretests on the test cable to include loss vs. frequency for all lines, background noise measurement and
xtalk matrix measurement (vectored mode).
This phase will provide a baseline for testing and identify any issues with test cable, connectors, noise
etc. As part of this testing, non-vectored and vectored performance will be tested on 48 lines for 400m
cable in fast mode. Single line rate performance will also be measured for 48 lines (note that this
measurement will take around 90 minutes for 48 lines as each line must be initialized separately).
A Python based scripting tool is available for automated data collection and presentation.
2.2 Vectoring performance
2.2.1 Purpose
An assessment of the vectoring performance can be realized by making comparisons between the so
called “single line” rate, “full fext” rate and the “vectored” rate.
In order to test the vectoring capabilities under sufficient processing load, it is recommended to include
at least 48 lines in the test.
Single line rate
Is the rate when only one line is active while all others are configured in “no admin-up” state. In this
case, no crosstalk is possible between the VDSL2 lines assigned for the vectoring test. It is possible that
other ADSLx services are present; as such there might be crosstalk impact on the VDSL2 rates in
vectored or non-vectored mode.
Full FEXT rates (or non-vectored rates)
Means that the rates are measured when all VDSL2 lines have stable Showtime and when vectoring is not
configured. This is the legacy VDSL2 mode.
Vectored rates
Means the stable Showtime rates when vectoring is enabled to cancel the FEXT.
2.2.2 Scenario 1
The following measurement sequence will be used for a subset of the profile combinations.
1. Single line mode
2. Full FEXT
3. Vectored mode
2.2.3 Output
Counters, operational, carrier and coefficient data will be acquired.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 7 of 29]
The 3 rates, both for US and DS and for the indicated 3 profiles, can be listed:
 Rate comparison SLR, FFR, VR
 Rate gain w.r.t. the legacy VDSL2 rates also known as FFR
 Efficiency VR w.r.t. the SLR
2.2.4 Actual Results
14 pairs 0Metre Downstream, Fast mode
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 8 of 29]
14 pairs 0Metre Upstream, Fast mode
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 9 of 29]
14 pairs 0Metre Fast mode , heat map
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 10 of 29]
3 FUNCTION/FEATURE TESTS
3.1 HSI Service
Objective
To verify the system supports HSI service.
Test Setup
Test procedure
1. Ensure 7356 REM and VDSL2 CPE is in service.
2. Configure the VDSL2 CPE to allow HSI service.
3. User to run speedtest service.
Expected Results
User is able to surf the internet.
Test Results
User is able to surf the internet.
Please refer to the wireshark traces, hsi_wireshark.rar.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 11 of 29]
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 12 of 29]
3.2 Multicast Service
Objective
To verify the system supports multicast service.
Test Setup
Test procedure
1. Ensure 7356 REM and VDSL2 CPE is in service.
2. Configure the VDSL2 CPE to allow unicast and multicast service.
Expected Results
User is able to view unicast and multicast video from the TV.
Test Results
User is able to view unicast and multicast video from the TV.
Please refer to the wireshark traces, vod_wireshark.rar & mcast_wireshark.rar.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 13 of 29]
3.3 Triple-play service
Objective
To verify the system supports triple-play service
Test Setup
Test procedure
1. Ensure 7356 REM and VDSL2 CPE is in service.
2. Configure the VDSL2 CPE to allow triple-play service.
Expected Results
User is able to view unicast and multicast video from the TV, surf internet and make voice calls via the
same VDSL2 CPE.
.
Test Results
User is able to view unicast and multicast video from the TV, surf internet and make voice calls via the
same VDSL2 CPE.
Please refer to the wireshark traces, hsi_wireshark.rar, vod_wireshark.rar, mcast_wireshark.rar,
sip_to_pstn.rar, pstn_to_sip.rar, sip_to_mobile.rar, mobile_to_sip.rar, sipA_to_sipB.rar,
sipB_to_sipA.rar, fax_to_sipfax.rar & sipfax_to_fax.rar.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 14 of 29]
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 15 of 29]
3.4 POTS Voice (SIP)
Objective
To verify voice service on SIP is working.
Test Setup
Test procedure
1. Ensure 2 POTS lines (A & B) are in service.
2. Check Dial tone
3. Make call between POTS (SIP) lines (A) to PSTN
4. Establish conversation for 3 minutes
5. End call
6. Repeat steps 3 to 5 for incoming call (PSTN call A).
7. Make call between POTS (SIP) lines (A) to Mobile
8. Establish conversation for 3 minutes
9. End call
10. Repeat steps 7 to 9 for incoming call (Mobile call A).
11. Make call between 2 POTS (SIP) lines (A call B)
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 16 of 29]
12. Establish conversation for 3 minutes
13. End call
14. Repeat steps 11 to 13 for incoming call (B call A).
15. Send fax between POTS (SIP) lines (A) to PSTN
16. End call after fax is sent successfully.
17. Repeat steps 15 to 16 for incoming call (PSTN fax A).
Expected Results
Calls from A to PSTN are established successfully and vice versa
Calls from A to Mobile are established successfully and vice versa.
Calls from A to B are established successfully and vice versa.
Fax calls from A to PSTN Fax are established successfully and vice versa.
Test Results
Calls from A to PSTN are established successfully and vice versa.
Please refer to the wireshark traces, sip_to_pstn.rar & pstn_to_sip.rar.
Calls from A to Mobile are established successfully and vice versa.
Please refer to the wireshark traces, sip_to_mobile.rar & mobile_to_sip.rar
Calls from A to B are established successfully and vice versa.
Please refer to the wireshark traces, sipA_to_sipB.rar & sipB_to_sipA.rar
Fax calls from A to PSTN Fax are established successfully and vice versa.
Please refer to the wireshark traces, fax_to_sipfax.rar & sipfax_to_fax.rar
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 17 of 29]
4 SYSTEM ACCEPTA NCE
4.1 FAN ALARM
Objective
To verify system supports FAN ALARM reporting
Test Setup
Test procedure
1. Ensure 7356REM is operational.
2. Remove the FAN from the 7356 REM shelf.
3. Re-insert the FAN into the 7356REM shelf.
Expected Results
FAN alarm is generated when the FAN is removed from the 7356REM shelf.
FAN alarm is cleared when the FAN is re-inserted into the 7356REM shelf.
Test Results
FAN alarm is generated when the FAN is removed from the 7356REM shelf.
FAN alarm is cleared when the FAN is re-inserted into the 7356REM shelf.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 18 of 29]
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 19 of 29]
4.2 POWER ALARM(A/B)
Objective
To verify system supports POWER ALARM reporting
Test Setup
Test procedure
1. Ensure 7356REM is operational and DC-A and DC-B are connected.
2. Disconnect DC-A power supply from 7356 REM shelf.
3. Re-connect DC-A power supply to 7356 REM shelf.
4. Disconnect DC-B power supply from 7356 REM shelf.
5. Re-connect DC-B power supply to 7356 REM shelf.
Expected Results
DCA alarm is generated when the DC-A power supply is disconnected from the 7356REM shelf.
DCA alarm is cleared when the DC-A power supply is re-connected to the 7356REM shelf.
DCB alarm is generated when the DC-B power supply is disconnected from the 7356REM shelf.
DCB alarm is cleared when the DC-B power supply is re-connected to the 7356REM shelf.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 20 of 29]
Test Results
DCA alarm is generated when the DC-A power supply is disconnected from the 7356REM shelf.
DCA alarm is cleared when the DC-A power supply is re-connected to the 7356REM shelf.
DCB alarm is generated when the DC-B power supply is disconnected from the 7356REM shelf.
DCB alarm is cleared when the DC-B power supply is re-connected to the 7356REM shelf.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 21 of 29]
4.3 Sync Rate of 48 VDSL Ports
Objective
To verify system supports 48 VDSL ports
Test Setup
Test procedure
1. Ensure 7356REM is operational.
2. Configure 48 VDSL2 line and connect 48 CPEs to the lines.
3. Record the sync rate of 48 VDSL ports.
Expected Results
System supports 48 VDSL ports.
Test Results
There are only 14 CPEs available on site.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 22 of 29]
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 23 of 29]
4.4 Voice Service on 48 ports
Objective
To verify system supports 48 voice ports
Test Setup
Test procedure
1. Ensure 7356REM is operational.
2. Configure 48 POTS line and connect 48 phones to the lines.
3. make calls between any two pots lines.
Expected Results
User is able to make calls between any two pots lines on the system.
Test Results
User is able to make calls between any two pots lines on the system.
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 24 of 29]
Please refer to the wireshark traces, sipA_to_sipB.rar & sipB_to_sipA.rar
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 25 of 29]
5 ISSUES ENCOUNTERED & OBSERVATIONS
Number Reported Date Description Solution Status Owner
1
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 26 of 29]
6 OFFICIAL ENDORSEMENT
Test Period
16 June 2014 & ended on 27 June 2014
Herewith the customer agrees with the trial test results for system under test.
Customer Representative(s)
Name Signature Date
Name Signature Date
Alcatel-Lucent Representative(s)
Name Signature Date
Name Signature Date
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 27 of 29]
7 ANNEX A - CLI CONFIGURATION OF PROPOSED PROFILES
7.1 SERVICE PROFILES
service-profile 1
(max rate DS, 50Mb/s
US rate, SRA US&DS,
Fast)
configure xdsl service-profile 1 name MaxUS_MaxDS_SRA_FAST
version 1
ra-mode-down dynamic
ra-mode-up dynamic
min-bit rate-down 32
min-bit rate-up 32
plan-bit rate-down 1024
max-bit rate-down 262140
max-bit rate-up 50000
max-delay-down 2
max-delay-up 2
imp-noise-prot-dn 0
imp-noise-prot-up 0
active
exit
ARQ will overrule the INP/Delay settings of IFEC and the rate settings configured in the service profile.
7.2 SPECTRUM PROFILES
spectrum-profile 1
(998ade, noUSPBO)
(default)
configure xdsl spectrum-profile 1 name VDSL2_noUPBO
version 1
dis-ansi-t1413
dis-etsi-dts
dis-g992-1-a
dis-g992-1-b
dis-g992-2-a
dis-g992-3-a
dis-g992-3-b
dis-etsi-ts
g993-2-8a
g993-2-8b
g993-2-8c
g993-2-8d
g993-2-12a
g993-2-12b
g993-2-17a
rf-band-list not-used
max-noise-down 240
max-noise-up 240
vdsl
vdsl-band-plan annex-b-998ade
propr-feat-value 0
optional-band up
optional-endfreq 138
adsl-band allow-adsl
pbo-mode pbo-mode-down
max-freq 17000
exit
vdsl2
propr-feat-value 2147483134
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 28 of 29]
max-agpowlev-down 205
max-agpowlev-up 145
psd-shape-down regionbm2-psd-down
psd-shape-up regionbm2-psd-up
exit
active
exit
7.3 RTX PROFILES
rtx-profile 1
(max rate DS, 50Mb/s US
rate)
configure xdsl vect-profile 1 name VECT_US_DS
version 1
no fext-cancel-up # value=enable
no fext-cancel-dn # value=enable
no dis-gvect-cpe
no gvecfriend-dn-cpe
no legacy-cpe
no band-control-up # value=""
no band-control-dn # value=""
no vect-leav-thresh # value=8
active
exit
7.4 VECTORING PROFILES
vect-profile 1
(Default US and DS
vectoring)
configure xdsl vect-profile 1 name VECT_US_DS
version 1
min-exp-thrpt-dn 2000
min-exp-thrpt-up 180
plan-exp-thrpt-dn 20000
plan-exp-thrpt-up 1024
max-exp-thrpt-dn 131000
max-exp-thrpt-up 50000
max-net-rate-dn 131000
max-net-rate-up 50000
shine-ratio-dn 0
shine-ratio-up 0
active
exit
7.5 VCE PROFILES
vce-profile 1 configure xdsl vce-profile 1 name VCE_DEFAULT
version 1
no vce-gain-mode # value=at-init
vce-join-timeout 20 # (def 15) but changed to 20
no vce-min-par-join # value=8
no vce-hist-pcoder # value=disable
no vce-band-plan # value=annex-b-998ade
active
exit
ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE
© Copyright 2014 Alcatel-Lucent
All Rights Reserved.
Revision 1
1 June 2015
[Page 29 of 29]
- END OF DOCUMENT -

Más contenido relacionado

La actualidad más candente

Huawei - Lte handover troubleshooting
Huawei - Lte handover troubleshootingHuawei - Lte handover troubleshooting
Huawei - Lte handover troubleshootingnavaidkhan
 
1574007558281387.pdf
1574007558281387.pdf1574007558281387.pdf
1574007558281387.pdfIslamAdam8
 
Huawei umts node b configuration principle
Huawei umts node b configuration principleHuawei umts node b configuration principle
Huawei umts node b configuration principleYaser Al-Abdali
 
Philippe Langlois - LTE Pwnage - P1security
Philippe Langlois - LTE Pwnage - P1securityPhilippe Langlois - LTE Pwnage - P1security
Philippe Langlois - LTE Pwnage - P1securityP1Security
 
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))Md Mustafizur Rahman
 
Best practices in synchronizing IP-based packet broadcasting networks
Best practices in synchronizing IP-based packet broadcasting networksBest practices in synchronizing IP-based packet broadcasting networks
Best practices in synchronizing IP-based packet broadcasting networksADVA
 
ALU 7360 5520_gpon_basic_configuration
ALU  7360 5520_gpon_basic_configurationALU  7360 5520_gpon_basic_configuration
ALU 7360 5520_gpon_basic_configurationWahyu Nasution
 
Hauwei Bts3900 gsm commissioning guide
Hauwei Bts3900 gsm  commissioning guideHauwei Bts3900 gsm  commissioning guide
Hauwei Bts3900 gsm commissioning guideengramjadislam78
 
Huawei sran site configration principles
Huawei sran site configration principlesHuawei sran site configration principles
Huawei sran site configration principlessiddharth singatiya
 
Huawei GPON Fundamentals
Huawei GPON FundamentalsHuawei GPON Fundamentals
Huawei GPON Fundamentalsibrahimnabil17
 
Synchronizing 5G networks
Synchronizing 5G networksSynchronizing 5G networks
Synchronizing 5G networksADVA
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentalsmansoor_gr8
 
02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-a02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-aWaheed Ali
 

La actualidad más candente (20)

Huawei bts3012 hardware structure issue1.0
Huawei bts3012 hardware structure issue1.0Huawei bts3012 hardware structure issue1.0
Huawei bts3012 hardware structure issue1.0
 
Huawei - Lte handover troubleshooting
Huawei - Lte handover troubleshootingHuawei - Lte handover troubleshooting
Huawei - Lte handover troubleshooting
 
1574007558281387.pdf
1574007558281387.pdf1574007558281387.pdf
1574007558281387.pdf
 
Huawei umts node b configuration principle
Huawei umts node b configuration principleHuawei umts node b configuration principle
Huawei umts node b configuration principle
 
Philippe Langlois - LTE Pwnage - P1security
Philippe Langlois - LTE Pwnage - P1securityPhilippe Langlois - LTE Pwnage - P1security
Philippe Langlois - LTE Pwnage - P1security
 
White space technology
White space technologyWhite space technology
White space technology
 
Huawei 5G Overview.pdf
Huawei 5G Overview.pdfHuawei 5G Overview.pdf
Huawei 5G Overview.pdf
 
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))
UMTS/3G RAN Capacity Management Guideline Part-02 (Sectorization))
 
Best practices in synchronizing IP-based packet broadcasting networks
Best practices in synchronizing IP-based packet broadcasting networksBest practices in synchronizing IP-based packet broadcasting networks
Best practices in synchronizing IP-based packet broadcasting networks
 
Gpon fundamentals
Gpon fundamentals Gpon fundamentals
Gpon fundamentals
 
ALU 7360 5520_gpon_basic_configuration
ALU  7360 5520_gpon_basic_configurationALU  7360 5520_gpon_basic_configuration
ALU 7360 5520_gpon_basic_configuration
 
Hauwei Bts3900 gsm commissioning guide
Hauwei Bts3900 gsm  commissioning guideHauwei Bts3900 gsm  commissioning guide
Hauwei Bts3900 gsm commissioning guide
 
Rtn
RtnRtn
Rtn
 
Huawei sran site configration principles
Huawei sran site configration principlesHuawei sran site configration principles
Huawei sran site configration principles
 
Huawei GPON Fundamentals
Huawei GPON FundamentalsHuawei GPON Fundamentals
Huawei GPON Fundamentals
 
ALU GPON TRAINING 3
ALU GPON TRAINING 3ALU GPON TRAINING 3
ALU GPON TRAINING 3
 
Opti x osn 1800 brochure
Opti x osn 1800 brochureOpti x osn 1800 brochure
Opti x osn 1800 brochure
 
Synchronizing 5G networks
Synchronizing 5G networksSynchronizing 5G networks
Synchronizing 5G networks
 
Gpon Fundamentals
Gpon FundamentalsGpon Fundamentals
Gpon Fundamentals
 
02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-a02 opti x rtn 900 v100r002 system hardware-20100223-a
02 opti x rtn 900 v100r002 system hardware-20100223-a
 

Destacado

VDSL Home Gateway Router - Copyright, all rights reserved.
VDSL Home Gateway Router - Copyright, all rights reserved.VDSL Home Gateway Router - Copyright, all rights reserved.
VDSL Home Gateway Router - Copyright, all rights reserved.David_Tickner
 
Alcatel lucent pt telkom turn-up guide v1
Alcatel lucent pt telkom turn-up guide v1Alcatel lucent pt telkom turn-up guide v1
Alcatel lucent pt telkom turn-up guide v1Wahyu Nasution
 
G.fast vs VDSL 35(b) VPLUS
G.fast vs VDSL 35(b) VPLUS G.fast vs VDSL 35(b) VPLUS
G.fast vs VDSL 35(b) VPLUS Sckipio
 
ZTE VDSL2 - A feasible solution for last mile
ZTE VDSL2 - A feasible solution for last mileZTE VDSL2 - A feasible solution for last mile
ZTE VDSL2 - A feasible solution for last mileAndrew Ariaratnam
 

Destacado (6)

VDSL Home Gateway Router - Copyright, all rights reserved.
VDSL Home Gateway Router - Copyright, all rights reserved.VDSL Home Gateway Router - Copyright, all rights reserved.
VDSL Home Gateway Router - Copyright, all rights reserved.
 
VDSL FOR TRIPLE PLAY
VDSL FOR TRIPLE PLAYVDSL FOR TRIPLE PLAY
VDSL FOR TRIPLE PLAY
 
Adsl
AdslAdsl
Adsl
 
Alcatel lucent pt telkom turn-up guide v1
Alcatel lucent pt telkom turn-up guide v1Alcatel lucent pt telkom turn-up guide v1
Alcatel lucent pt telkom turn-up guide v1
 
G.fast vs VDSL 35(b) VPLUS
G.fast vs VDSL 35(b) VPLUS G.fast vs VDSL 35(b) VPLUS
G.fast vs VDSL 35(b) VPLUS
 
ZTE VDSL2 - A feasible solution for last mile
ZTE VDSL2 - A feasible solution for last mileZTE VDSL2 - A feasible solution for last mile
ZTE VDSL2 - A feasible solution for last mile
 

Similar a VDSL Vectoring TEST PT TELKOM ALCATEL LUCENT

Transport SDN & OpenDaylight Use Cases in Korea
Transport SDN & OpenDaylight Use Cases in KoreaTransport SDN & OpenDaylight Use Cases in Korea
Transport SDN & OpenDaylight Use Cases in KoreaJustin Park
 
JVL Industrial Ethernet Expansion Modules for MAC Motors
JVL Industrial Ethernet Expansion Modules for MAC MotorsJVL Industrial Ethernet Expansion Modules for MAC Motors
JVL Industrial Ethernet Expansion Modules for MAC MotorsElectromate
 
Rail-net Indian railway internet
Rail-net Indian railway internetRail-net Indian railway internet
Rail-net Indian railway internetRahul Kumar
 
configuration of switch campus network
configuration of switch campus networkconfiguration of switch campus network
configuration of switch campus networksubhash subbu
 
Arista Nuage meetup dublin 18-2
Arista Nuage meetup dublin 18-2Arista Nuage meetup dublin 18-2
Arista Nuage meetup dublin 18-2Patrick Lynchehaun
 
Traditional Queue Management v/s Active Queue Management for Controlling Cong...
Traditional Queue Management v/s Active Queue Management for Controlling Cong...Traditional Queue Management v/s Active Queue Management for Controlling Cong...
Traditional Queue Management v/s Active Queue Management for Controlling Cong...IRJET Journal
 
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentation
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentationTurbocharge the NFV Data Plane in the SDN Era - a Radisys presentation
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentationRadisys Corporation
 
Veryx Product Catalog - ATTEST
Veryx Product Catalog - ATTESTVeryx Product Catalog - ATTEST
Veryx Product Catalog - ATTESTVeryx Technologies
 
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼NAIM Networks, Inc.
 
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2IRJET Journal
 
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktycznie
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktyczniePLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktycznie
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktyczniePROIDEA
 

Similar a VDSL Vectoring TEST PT TELKOM ALCATEL LUCENT (20)

Transport SDN & OpenDaylight Use Cases in Korea
Transport SDN & OpenDaylight Use Cases in KoreaTransport SDN & OpenDaylight Use Cases in Korea
Transport SDN & OpenDaylight Use Cases in Korea
 
JVL Industrial Ethernet Expansion Modules for MAC Motors
JVL Industrial Ethernet Expansion Modules for MAC MotorsJVL Industrial Ethernet Expansion Modules for MAC Motors
JVL Industrial Ethernet Expansion Modules for MAC Motors
 
Railnet
RailnetRailnet
Railnet
 
Rail-net Indian railway internet
Rail-net Indian railway internetRail-net Indian railway internet
Rail-net Indian railway internet
 
configuration of switch campus network
configuration of switch campus networkconfiguration of switch campus network
configuration of switch campus network
 
Ati sbx908-ds
Ati sbx908-dsAti sbx908-ds
Ati sbx908-ds
 
Arista Nuage meetup dublin 18-2
Arista Nuage meetup dublin 18-2Arista Nuage meetup dublin 18-2
Arista Nuage meetup dublin 18-2
 
OmniSwitch 6860/E Overview
OmniSwitch 6860/E Overview OmniSwitch 6860/E Overview
OmniSwitch 6860/E Overview
 
Traditional Queue Management v/s Active Queue Management for Controlling Cong...
Traditional Queue Management v/s Active Queue Management for Controlling Cong...Traditional Queue Management v/s Active Queue Management for Controlling Cong...
Traditional Queue Management v/s Active Queue Management for Controlling Cong...
 
PROFINET network qualification Peter Thomas - oct 2015
PROFINET network qualification   Peter Thomas - oct 2015PROFINET network qualification   Peter Thomas - oct 2015
PROFINET network qualification Peter Thomas - oct 2015
 
CCNA 2
CCNA 2 CCNA 2
CCNA 2
 
Ies5000 usg
Ies5000 usgIes5000 usg
Ies5000 usg
 
Viavi Perfect OTDR
Viavi Perfect OTDRViavi Perfect OTDR
Viavi Perfect OTDR
 
Cma5000a uta
Cma5000a utaCma5000a uta
Cma5000a uta
 
Profinet network qualification - Peter Thomas
Profinet network qualification - Peter ThomasProfinet network qualification - Peter Thomas
Profinet network qualification - Peter Thomas
 
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentation
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentationTurbocharge the NFV Data Plane in the SDN Era - a Radisys presentation
Turbocharge the NFV Data Plane in the SDN Era - a Radisys presentation
 
Veryx Product Catalog - ATTEST
Veryx Product Catalog - ATTESTVeryx Product Catalog - ATTEST
Veryx Product Catalog - ATTEST
 
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼
OVNC 2015-서비스 에지 가상화를 위한 NFV/SDN 플랫폼
 
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2
IRJET- Comparative Performance Analysis of Routing Protocols in Manet using NS-2
 
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktycznie
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktyczniePLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktycznie
PLNOG 7: Klaudiusz Staniek - MPLS a QoS - praktycznie
 

Más de Wahyu Nasution

Ft tx presentation to telkom 25092013
Ft tx presentation to telkom 25092013Ft tx presentation to telkom 25092013
Ft tx presentation to telkom 25092013Wahyu Nasution
 
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkomGpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkomWahyu Nasution
 
ISAM ALU 7360 5520_ihub_turn_up_procedure
ISAM ALU  7360 5520_ihub_turn_up_procedureISAM ALU  7360 5520_ihub_turn_up_procedure
ISAM ALU 7360 5520_ihub_turn_up_procedureWahyu Nasution
 
Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2Wahyu Nasution
 
Manual guide briker IP PABX
Manual guide briker IP PABX Manual guide briker IP PABX
Manual guide briker IP PABX Wahyu Nasution
 
Gateway load balancing protocol
Gateway load balancing protocolGateway load balancing protocol
Gateway load balancing protocolWahyu Nasution
 
Cisco hsrp configuration
Cisco hsrp configurationCisco hsrp configuration
Cisco hsrp configurationWahyu Nasution
 

Más de Wahyu Nasution (12)

Ft tx presentation to telkom 25092013
Ft tx presentation to telkom 25092013Ft tx presentation to telkom 25092013
Ft tx presentation to telkom 25092013
 
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkomGpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
Gpon omci v2__voice_configuration_introduction_omciv2_v2_pt_telkom
 
Ams operations
Ams operationsAms operations
Ams operations
 
ISAM ALU 7360 5520_ihub_turn_up_procedure
ISAM ALU  7360 5520_ihub_turn_up_procedureISAM ALU  7360 5520_ihub_turn_up_procedure
ISAM ALU 7360 5520_ihub_turn_up_procedure
 
Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2Alcatel Lucent Gpon Technology Training 2
Alcatel Lucent Gpon Technology Training 2
 
ALU GPON TRAINING 1
ALU GPON TRAINING 1ALU GPON TRAINING 1
ALU GPON TRAINING 1
 
Manual guide briker IP PABX
Manual guide briker IP PABX Manual guide briker IP PABX
Manual guide briker IP PABX
 
Bgp tutorial for ISP
Bgp tutorial for ISPBgp tutorial for ISP
Bgp tutorial for ISP
 
Ip sec training
Ip sec trainingIp sec training
Ip sec training
 
Gateway load balancing protocol
Gateway load balancing protocolGateway load balancing protocol
Gateway load balancing protocol
 
Cisco hsrp configuration
Cisco hsrp configurationCisco hsrp configuration
Cisco hsrp configuration
 
Ipsec rbe guide
Ipsec rbe guideIpsec rbe guide
Ipsec rbe guide
 

Último

🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘RTylerCroy
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...Martijn de Jong
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processorsdebabhi2
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationMichael W. Hawkins
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxKatpro Technologies
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024Rafal Los
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking MenDelhi Call girls
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024Results
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Scriptwesley chun
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Servicegiselly40
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityPrincipled Technologies
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Drew Madelung
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreternaman860154
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountPuma Security, LLC
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking MenDelhi Call girls
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfEnterprise Knowledge
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfsudhanshuwaghmare1
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?Igalia
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking MenDelhi Call girls
 

Último (20)

🐬 The future of MySQL is Postgres 🐘
🐬  The future of MySQL is Postgres   🐘🐬  The future of MySQL is Postgres   🐘
🐬 The future of MySQL is Postgres 🐘
 
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law DevelopmentsTrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
TrustArc Webinar - Stay Ahead of US State Data Privacy Law Developments
 
2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...2024: Domino Containers - The Next Step. News from the Domino Container commu...
2024: Domino Containers - The Next Step. News from the Domino Container commu...
 
Exploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone ProcessorsExploring the Future Potential of AI-Enabled Smartphone Processors
Exploring the Future Potential of AI-Enabled Smartphone Processors
 
GenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day PresentationGenCyber Cyber Security Day Presentation
GenCyber Cyber Security Day Presentation
 
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptxFactors to Consider When Choosing Accounts Payable Services Providers.pptx
Factors to Consider When Choosing Accounts Payable Services Providers.pptx
 
The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024The 7 Things I Know About Cyber Security After 25 Years | April 2024
The 7 Things I Know About Cyber Security After 25 Years | April 2024
 
08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men08448380779 Call Girls In Friends Colony Women Seeking Men
08448380779 Call Girls In Friends Colony Women Seeking Men
 
A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024A Call to Action for Generative AI in 2024
A Call to Action for Generative AI in 2024
 
Automating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps ScriptAutomating Google Workspace (GWS) & more with Apps Script
Automating Google Workspace (GWS) & more with Apps Script
 
CNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of ServiceCNv6 Instructor Chapter 6 Quality of Service
CNv6 Instructor Chapter 6 Quality of Service
 
Boost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivityBoost PC performance: How more available memory can improve productivity
Boost PC performance: How more available memory can improve productivity
 
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
Strategies for Unlocking Knowledge Management in Microsoft 365 in the Copilot...
 
Presentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreterPresentation on how to chat with PDF using ChatGPT code interpreter
Presentation on how to chat with PDF using ChatGPT code interpreter
 
Breaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path MountBreaking the Kubernetes Kill Chain: Host Path Mount
Breaking the Kubernetes Kill Chain: Host Path Mount
 
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
08448380779 Call Girls In Diplomatic Enclave Women Seeking Men
 
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdfThe Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
The Role of Taxonomy and Ontology in Semantic Layers - Heather Hedden.pdf
 
Boost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdfBoost Fertility New Invention Ups Success Rates.pdf
Boost Fertility New Invention Ups Success Rates.pdf
 
A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?A Year of the Servo Reboot: Where Are We Now?
A Year of the Servo Reboot: Where Are We Now?
 
08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men08448380779 Call Girls In Civil Lines Women Seeking Men
08448380779 Call Girls In Civil Lines Women Seeking Men
 

VDSL Vectoring TEST PT TELKOM ALCATEL LUCENT

  • 1. ISAM FD General Test Plan VDSL2, Vectoring Alcatel-Lucent Fixed Networks APAC RBC Customer Engineering Revision 1 22 April 2014
  • 2. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 2 of 29] LEGAL NOTICE Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective owners. The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein. Copyright © 2014 Alcatel-Lucent. All Rights Reserved. This document contains proprietary/trade secret information which is the property of Alcatel-Lucent and must not be made available to, or copied or used by anyone outside Alcatel-Lucent without its written authorization.
  • 3. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 3 of 29] Table of contents 1 CONFIGURA TION UNDER TEST .............................................................................................. 4 1.1 SUMMARY.............................................................................................................................4 1.2 SYSTEM UNDER TEST ...............................................................................................................4 1.3 TEST DIAGRAM ......................................................................................................................5 1.4 PREREQUISITES......................................................................................................................5 2 VECTORING TESTS .................................................................................................................. 6 2.1 SYSTEM SETUP AND PRE-TESTS...................................................................................................6 2.2 VECTORING PERFORMANCE........................................................................................................6 3 FUNCTION/FEA TURE TESTS ................................................................................................. 10 3.1 HSI SERVICE.......................................................................................................................10 3.2 MULTICAST SERVICE..............................................................................................................12 3.3 TRIPLE-PLAY SERVICE ............................................................................................................13 3.4 POTS VOICE (SIP) ..............................................................................................................15 4 SYSTEM ACCEPTA NCE ........................................................................................................... 17 4.1 FAN ALARM.......................................................................................................................17 4.2 POWER ALARM(A/B)..........................................................................................................19 4.3 SYNC RATE OF 48 VDSL PORTS...............................................................................................21 4.4 VOICE SERVICE ON 48 PORTS ..................................................................................................23 5 ISSUES ENCOUNTERED & OBSERVATIONS ......................................................................... 25 6 OFFICIAL ENDORSEMENT ..................................................................................................... 26 7 ANNEX A - CLI CONFIGURA TION OF PROPOSED PROFILES............................................... 27 7.1 SERVICE PROFILES ...........................................................................................................27 7.2 SPECTRUM PROFILES........................................................................................................27 7.3 VECTORING PROFILES ......................................................................................................28 7.4 VCE PROFILES ..................................................................................................................28
  • 4. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 4 of 29] 1 CONFIGURATION UNDER TEST 1.1 Summary This document contains test plan for VDSL2 vectoring based on Alcatel-Lucent Board Level Vectoring Solution. 1.2 System under test Procedures are verified with the following configuration: Enclosure 7356 7360FX NT Controller (software) NRNT-A(5.0.122) FANT-F (4.6.477) ELT NDLT-C, 48L VDSL2 card with BLV NPOT-C, 48 line POTs card NVSP-B, 48 port POTS VDSL Splitter OLT NGLT-C, 8-GPON Line Termination Board Vectoring CPEs Sagemcom F@ST5310 ONT O-010S-P, SFP ONT
  • 5. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 5 of 29] 1.3 Test Diagram 1.4 Prerequisites 1.4.1 Real cable At least one real cable with multiple pairs, in order to have real crosstalk between various DSL lines. Amount of pairs: 48 pairs is proposed for the field trial. The cable should be representative of real cable in use in the customer’s distribution network. In particular the binder structure of the cable should be representative of actual cables. Length: preferably between 400 m - 500 m, maximum 1000 m (on longer cable lengths, vectoring gains are lower) Multiple cables or cable lengths can be tested if available. 1.4.2 VDSL profiles ANNEX A - CLI CONFIGURATION OF PROPOSED PROFILES of this document contains ALU proposed profiles to be used for the testing.
  • 6. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 6 of 29] 2 VECTORING TESTS 2.1 System setup and pre-tests Set-up equipment in lab and connect to test cable. Pretests on the test cable to include loss vs. frequency for all lines, background noise measurement and xtalk matrix measurement (vectored mode). This phase will provide a baseline for testing and identify any issues with test cable, connectors, noise etc. As part of this testing, non-vectored and vectored performance will be tested on 48 lines for 400m cable in fast mode. Single line rate performance will also be measured for 48 lines (note that this measurement will take around 90 minutes for 48 lines as each line must be initialized separately). A Python based scripting tool is available for automated data collection and presentation. 2.2 Vectoring performance 2.2.1 Purpose An assessment of the vectoring performance can be realized by making comparisons between the so called “single line” rate, “full fext” rate and the “vectored” rate. In order to test the vectoring capabilities under sufficient processing load, it is recommended to include at least 48 lines in the test. Single line rate Is the rate when only one line is active while all others are configured in “no admin-up” state. In this case, no crosstalk is possible between the VDSL2 lines assigned for the vectoring test. It is possible that other ADSLx services are present; as such there might be crosstalk impact on the VDSL2 rates in vectored or non-vectored mode. Full FEXT rates (or non-vectored rates) Means that the rates are measured when all VDSL2 lines have stable Showtime and when vectoring is not configured. This is the legacy VDSL2 mode. Vectored rates Means the stable Showtime rates when vectoring is enabled to cancel the FEXT. 2.2.2 Scenario 1 The following measurement sequence will be used for a subset of the profile combinations. 1. Single line mode 2. Full FEXT 3. Vectored mode 2.2.3 Output Counters, operational, carrier and coefficient data will be acquired.
  • 7. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 7 of 29] The 3 rates, both for US and DS and for the indicated 3 profiles, can be listed:  Rate comparison SLR, FFR, VR  Rate gain w.r.t. the legacy VDSL2 rates also known as FFR  Efficiency VR w.r.t. the SLR 2.2.4 Actual Results 14 pairs 0Metre Downstream, Fast mode
  • 8. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 8 of 29] 14 pairs 0Metre Upstream, Fast mode
  • 9. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 9 of 29] 14 pairs 0Metre Fast mode , heat map
  • 10. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 10 of 29] 3 FUNCTION/FEATURE TESTS 3.1 HSI Service Objective To verify the system supports HSI service. Test Setup Test procedure 1. Ensure 7356 REM and VDSL2 CPE is in service. 2. Configure the VDSL2 CPE to allow HSI service. 3. User to run speedtest service. Expected Results User is able to surf the internet. Test Results User is able to surf the internet. Please refer to the wireshark traces, hsi_wireshark.rar.
  • 11. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 11 of 29]
  • 12. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 12 of 29] 3.2 Multicast Service Objective To verify the system supports multicast service. Test Setup Test procedure 1. Ensure 7356 REM and VDSL2 CPE is in service. 2. Configure the VDSL2 CPE to allow unicast and multicast service. Expected Results User is able to view unicast and multicast video from the TV. Test Results User is able to view unicast and multicast video from the TV. Please refer to the wireshark traces, vod_wireshark.rar & mcast_wireshark.rar.
  • 13. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 13 of 29] 3.3 Triple-play service Objective To verify the system supports triple-play service Test Setup Test procedure 1. Ensure 7356 REM and VDSL2 CPE is in service. 2. Configure the VDSL2 CPE to allow triple-play service. Expected Results User is able to view unicast and multicast video from the TV, surf internet and make voice calls via the same VDSL2 CPE. . Test Results User is able to view unicast and multicast video from the TV, surf internet and make voice calls via the same VDSL2 CPE. Please refer to the wireshark traces, hsi_wireshark.rar, vod_wireshark.rar, mcast_wireshark.rar, sip_to_pstn.rar, pstn_to_sip.rar, sip_to_mobile.rar, mobile_to_sip.rar, sipA_to_sipB.rar, sipB_to_sipA.rar, fax_to_sipfax.rar & sipfax_to_fax.rar.
  • 14. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 14 of 29]
  • 15. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 15 of 29] 3.4 POTS Voice (SIP) Objective To verify voice service on SIP is working. Test Setup Test procedure 1. Ensure 2 POTS lines (A & B) are in service. 2. Check Dial tone 3. Make call between POTS (SIP) lines (A) to PSTN 4. Establish conversation for 3 minutes 5. End call 6. Repeat steps 3 to 5 for incoming call (PSTN call A). 7. Make call between POTS (SIP) lines (A) to Mobile 8. Establish conversation for 3 minutes 9. End call 10. Repeat steps 7 to 9 for incoming call (Mobile call A). 11. Make call between 2 POTS (SIP) lines (A call B)
  • 16. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 16 of 29] 12. Establish conversation for 3 minutes 13. End call 14. Repeat steps 11 to 13 for incoming call (B call A). 15. Send fax between POTS (SIP) lines (A) to PSTN 16. End call after fax is sent successfully. 17. Repeat steps 15 to 16 for incoming call (PSTN fax A). Expected Results Calls from A to PSTN are established successfully and vice versa Calls from A to Mobile are established successfully and vice versa. Calls from A to B are established successfully and vice versa. Fax calls from A to PSTN Fax are established successfully and vice versa. Test Results Calls from A to PSTN are established successfully and vice versa. Please refer to the wireshark traces, sip_to_pstn.rar & pstn_to_sip.rar. Calls from A to Mobile are established successfully and vice versa. Please refer to the wireshark traces, sip_to_mobile.rar & mobile_to_sip.rar Calls from A to B are established successfully and vice versa. Please refer to the wireshark traces, sipA_to_sipB.rar & sipB_to_sipA.rar Fax calls from A to PSTN Fax are established successfully and vice versa. Please refer to the wireshark traces, fax_to_sipfax.rar & sipfax_to_fax.rar
  • 17. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 17 of 29] 4 SYSTEM ACCEPTA NCE 4.1 FAN ALARM Objective To verify system supports FAN ALARM reporting Test Setup Test procedure 1. Ensure 7356REM is operational. 2. Remove the FAN from the 7356 REM shelf. 3. Re-insert the FAN into the 7356REM shelf. Expected Results FAN alarm is generated when the FAN is removed from the 7356REM shelf. FAN alarm is cleared when the FAN is re-inserted into the 7356REM shelf. Test Results FAN alarm is generated when the FAN is removed from the 7356REM shelf. FAN alarm is cleared when the FAN is re-inserted into the 7356REM shelf.
  • 18. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 18 of 29]
  • 19. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 19 of 29] 4.2 POWER ALARM(A/B) Objective To verify system supports POWER ALARM reporting Test Setup Test procedure 1. Ensure 7356REM is operational and DC-A and DC-B are connected. 2. Disconnect DC-A power supply from 7356 REM shelf. 3. Re-connect DC-A power supply to 7356 REM shelf. 4. Disconnect DC-B power supply from 7356 REM shelf. 5. Re-connect DC-B power supply to 7356 REM shelf. Expected Results DCA alarm is generated when the DC-A power supply is disconnected from the 7356REM shelf. DCA alarm is cleared when the DC-A power supply is re-connected to the 7356REM shelf. DCB alarm is generated when the DC-B power supply is disconnected from the 7356REM shelf. DCB alarm is cleared when the DC-B power supply is re-connected to the 7356REM shelf.
  • 20. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 20 of 29] Test Results DCA alarm is generated when the DC-A power supply is disconnected from the 7356REM shelf. DCA alarm is cleared when the DC-A power supply is re-connected to the 7356REM shelf. DCB alarm is generated when the DC-B power supply is disconnected from the 7356REM shelf. DCB alarm is cleared when the DC-B power supply is re-connected to the 7356REM shelf.
  • 21. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 21 of 29] 4.3 Sync Rate of 48 VDSL Ports Objective To verify system supports 48 VDSL ports Test Setup Test procedure 1. Ensure 7356REM is operational. 2. Configure 48 VDSL2 line and connect 48 CPEs to the lines. 3. Record the sync rate of 48 VDSL ports. Expected Results System supports 48 VDSL ports. Test Results There are only 14 CPEs available on site.
  • 22. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 22 of 29]
  • 23. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 23 of 29] 4.4 Voice Service on 48 ports Objective To verify system supports 48 voice ports Test Setup Test procedure 1. Ensure 7356REM is operational. 2. Configure 48 POTS line and connect 48 phones to the lines. 3. make calls between any two pots lines. Expected Results User is able to make calls between any two pots lines on the system. Test Results User is able to make calls between any two pots lines on the system.
  • 24. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 24 of 29] Please refer to the wireshark traces, sipA_to_sipB.rar & sipB_to_sipA.rar
  • 25. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 25 of 29] 5 ISSUES ENCOUNTERED & OBSERVATIONS Number Reported Date Description Solution Status Owner 1
  • 26. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 26 of 29] 6 OFFICIAL ENDORSEMENT Test Period 16 June 2014 & ended on 27 June 2014 Herewith the customer agrees with the trial test results for system under test. Customer Representative(s) Name Signature Date Name Signature Date Alcatel-Lucent Representative(s) Name Signature Date Name Signature Date
  • 27. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 27 of 29] 7 ANNEX A - CLI CONFIGURATION OF PROPOSED PROFILES 7.1 SERVICE PROFILES service-profile 1 (max rate DS, 50Mb/s US rate, SRA US&DS, Fast) configure xdsl service-profile 1 name MaxUS_MaxDS_SRA_FAST version 1 ra-mode-down dynamic ra-mode-up dynamic min-bit rate-down 32 min-bit rate-up 32 plan-bit rate-down 1024 max-bit rate-down 262140 max-bit rate-up 50000 max-delay-down 2 max-delay-up 2 imp-noise-prot-dn 0 imp-noise-prot-up 0 active exit ARQ will overrule the INP/Delay settings of IFEC and the rate settings configured in the service profile. 7.2 SPECTRUM PROFILES spectrum-profile 1 (998ade, noUSPBO) (default) configure xdsl spectrum-profile 1 name VDSL2_noUPBO version 1 dis-ansi-t1413 dis-etsi-dts dis-g992-1-a dis-g992-1-b dis-g992-2-a dis-g992-3-a dis-g992-3-b dis-etsi-ts g993-2-8a g993-2-8b g993-2-8c g993-2-8d g993-2-12a g993-2-12b g993-2-17a rf-band-list not-used max-noise-down 240 max-noise-up 240 vdsl vdsl-band-plan annex-b-998ade propr-feat-value 0 optional-band up optional-endfreq 138 adsl-band allow-adsl pbo-mode pbo-mode-down max-freq 17000 exit vdsl2 propr-feat-value 2147483134
  • 28. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 28 of 29] max-agpowlev-down 205 max-agpowlev-up 145 psd-shape-down regionbm2-psd-down psd-shape-up regionbm2-psd-up exit active exit 7.3 RTX PROFILES rtx-profile 1 (max rate DS, 50Mb/s US rate) configure xdsl vect-profile 1 name VECT_US_DS version 1 no fext-cancel-up # value=enable no fext-cancel-dn # value=enable no dis-gvect-cpe no gvecfriend-dn-cpe no legacy-cpe no band-control-up # value="" no band-control-dn # value="" no vect-leav-thresh # value=8 active exit 7.4 VECTORING PROFILES vect-profile 1 (Default US and DS vectoring) configure xdsl vect-profile 1 name VECT_US_DS version 1 min-exp-thrpt-dn 2000 min-exp-thrpt-up 180 plan-exp-thrpt-dn 20000 plan-exp-thrpt-up 1024 max-exp-thrpt-dn 131000 max-exp-thrpt-up 50000 max-net-rate-dn 131000 max-net-rate-up 50000 shine-ratio-dn 0 shine-ratio-up 0 active exit 7.5 VCE PROFILES vce-profile 1 configure xdsl vce-profile 1 name VCE_DEFAULT version 1 no vce-gain-mode # value=at-init vce-join-timeout 20 # (def 15) but changed to 20 no vce-min-par-join # value=8 no vce-hist-pcoder # value=disable no vce-band-plan # value=annex-b-998ade active exit
  • 29. ISAM FD VDSL VECTORING - TEST PLAN & PROCEDURE © Copyright 2014 Alcatel-Lucent All Rights Reserved. Revision 1 1 June 2015 [Page 29 of 29] - END OF DOCUMENT -