4. : کنیم می مشاهده را مربوطه پشتیبانی جدول زیر در
2 2 3 3
Table for using sas flsh/sas flash/sas flsh/sas flash
Case Flash From Flash To
Motherboard
used
SAS2Flash/
SAS3Flash OS
version
Command
(example shows
sas2flsh/sas2flash; use
sas3flsh/sas3flash if using 12
Gb/sec SAS)
1
Older IT
firmware
Newer IT
Firmware
Any except
SMX9
DOS/EFI/
Windows/
Linux/
Solaris
(DOS): sas2flsh -o -f
(All other OS): sas2flash -o
-f
2
Older IT
firmware and
BIOS
Newer IT
Firmware and
BIOS
Any except
SMX9
DOS/EFI/
Windows/
Linux/
Solaris
(DOS): sas2flsh -o -f
(All other OS): sas2flash -o
-f
example: sas2flsh -o -f
2118it.bin -b mpt2sas.rom
3
Newer IT
Firmware and
BIOS
Older IT
firmware and
BIOS
Any except
SMX9
DOS or EFI
(DOS):
sas2flsh -o -e 6
sas2flsh -o -f
sas2flsh -o -f
4a
Older IR
firmware
Newer IR
Firmware
Any except
SMX9
DOS/EFI/
Windows/
Linux/
Solaris
(DOS): sas2flsh -o -f
(All other OS): sas2flash -o -f
4b
Older IR
firmware and
BIOS
Newer IR
Firmware and
BIOS
Any except
SMX9
DOS/EFI/
Windows/
Linux/
Solaris
(DOS): sas2flsh -o -f
(All other OS): sas2flash -o
-f
5
Newer IR
Firmware and
BIOS
Older IR
firmware and
BIOS
Any except
SMX9
DOS or EFI
(DOS): sas2flsh -o -f
(All other OS): sas2flash -o
-f
6*
Any version
IT firmware
Any version
IR firmware
Any except
SMX9
DOS or EFI
(DOS):
sas2flsh -o -e 6
sas2flsh -o -f
sas2flsh -o -f
5. 7*
Any version
IR firmware
Any version
IT firmware
Any except
SMX9
DOS or EFI
(DOS):
sas2flsh -o -e 6
sas2flsh -o -f
sas2flsh -o -f
8
Older IT
firmware
Newer IT
firmware
SMX9
EFI/
Windows/
Linux/
Solaris
sas2flash -o -f
9
Older IT
firmware and
BIOS
Newer IT
firmware and
BIOS
SMX9
EFI/
Windows/
Linux/
Solaris
sas2flash -o -f
10
Newer IT
firmware
Older IT
firmware
SMX9 EFI sas2flash.efi -o -f
11 Any BIOS Any BIOS SMX9
Windows/
Linux/
Solaris
sas2flash -o -b
12
Older IR
firmware
Newer IR
firmware
SMX9
Windows/
Linux/
Solaris
sas2flash -o -f
13
Newer IR
firmware
Older IR
firmware
SMX9 EFI sas2flash.efi -o -f
: نکته
کردن فلش هنگام *
12
HBA G
خانواده(
9300
SAS
حالت فرمور با )
IR
نام به ،بسته همان در
9311
،
3
SAS Flash
:گرداند
یبرم را زیر خطای
ERROR: NVDATA Image does not match Controller Subsystem ID!
ERROR: No compatible NVDATA Image(s) found!
Firmware Image Validation Failed!
6. : حل روش
3 10.00.00.01
Using DOS or EFI SAS Flash version or higher with following command string
3 6
sas flsh –o –e -
3
sas flsh –o –f
:
EFI
3
sas flash –o –f
منبع
10. میتوانیم زیر دستور با
کنی دریافت را آداپتورها همه پیکربندی و وضعیت
م
:
megacli -AdpAllInfo -aAll
Adapter #0
==============================================================================
Versions
================
Product Name : ServeRAID M5014 SAS/SATA Controller
Serial No : SV01506370
FW Package Build: 12.15.0-0199
Mfg. Data
================
Mfg. Date : 04/10/10
Rework Date : 00/00/00
Revision No :
Battery FRU : N/A
Image Versions in Flash:
================
FW Version : 2.130.403-3588
BIOS Version : 3.30.02.2_4.16.08.00_0x06060A05
Preboot CLI Version: 04.04-020:#%00009
WebBIOS Version : 6.0-53-e_49-Rel
NVDATA Version : 2.09.03-0051
Boot Block Version : 2.02.00.00-0000
BOOT Version : 09.250.01.219
[...]
: کنیم تحلیل تجزیه و بررسی را منطقی درایو نوع و وضعیت
11. megacli -LDInfo -L0 -a0
Adapter 0 -- Virtual Drive Information:
Virtual Drive: 0 (Target Id: 0)
Name :
RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0
Size : 135.972 GB
Sector Size : 512
Mirror Data : 135.972 GB
State : Optimal
Strip Size : 128 KB
Number Of Drives : 2
Span Depth : 1
Default Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad
BBU
Current Cache Policy: WriteThrough, ReadAheadNone, Direct, No Write Cache if Bad
BBU
Default Access Policy: Read/Write
Current Access Policy: Read/Write
Disk Cache Policy : Disabled
Encryption Type : None
Is VD Cached: No
Exit Code: 0x00
12. :کنترلر اولین از فیزیکی های دیسک نمایش
megacli -PDList -a0
Adapter #0
Enclosure Device ID: 252
Slot Number: 0
Enclosure position: N/A
Device Id: 13
WWN: 5000C50023595FFC
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 1
Last Predictive Failure Event Seq Number: 54338
PD Type: SAS
Hotspare Information:
Type: Global, is revertible
Raw Size: 136.731 GB [0x11176d60 Sectors]
Non Coerced Size: 136.231 GB [0x11076d60 Sectors]
Coerced Size: 135.972 GB [0x10ff2000 Sectors]
Sector Size: 0
Firmware state: Hotspare, Spun Up
Device Firmware Level: B62C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c50023595ffd
SAS Address(1): 0x0
Connected Port Number: 2(path0)
Inquiry Data: IBM-ESXSST9146852SS B62C3TB19TDM0324B62C
IBM FRU/CRU: 42D0668
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :32C (89.60 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
13. Drive has flagged a S.M.A.R.T alert : Yes
Enclosure Device ID: 252
Slot Number: 1
Drive's position: DiskGroup: 0, Span: 0, Arm: 0
Enclosure position: N/A
Device Id: 10
WWN: 5000C500235A1D08
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 136.731 GB [0x11176d60 Sectors]
Non Coerced Size: 136.231 GB [0x11076d60 Sectors]
Coerced Size: 135.972 GB [0x10ff2000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: B62C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c500235a1d09
SAS Address(1): 0x0
Connected Port Number: 1(path0)
Inquiry Data: IBM-ESXSST9146852SS B62C3TB1H60G0324B62C
IBM FRU/CRU: 42D0668
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :35C (95.00 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Enclosure Device ID: 252
Slot Number: 2
Drive's position: DiskGroup: 0, Span: 0, Arm: 1
14. Enclosure position: N/A
Device Id: 9
WWN: 5000C500235A08D8
Sequence Number: 2
Media Error Count: 0
Other Error Count: 0
Predictive Failure Count: 0
Last Predictive Failure Event Seq Number: 0
PD Type: SAS
Raw Size: 136.731 GB [0x11176d60 Sectors]
Non Coerced Size: 136.231 GB [0x11076d60 Sectors]
Coerced Size: 135.972 GB [0x10ff2000 Sectors]
Sector Size: 0
Firmware state: Online, Spun Up
Commissioned Spare : No
Emergency Spare : No
Device Firmware Level: B62C
Shield Counter: 0
Successful diagnostics completion on : N/A
SAS Address(0): 0x5000c500235a08d9
SAS Address(1): 0x0
Connected Port Number: 0(path0)
Inquiry Data: IBM-ESXSST9146852SS B62C3TB1H5J50324B62C
IBM FRU/CRU: 42D0668
FDE Capable: Not Capable
FDE Enable: Disable
Secured: Unsecured
Locked: Unlocked
Needs EKM Attention: No
Foreign State: None
Device Speed: 6.0Gb/s
Link Speed: 6.0Gb/s
Media Type: Hard Disk Device
Drive: Not Certified
Drive Temperature :31C (87.80 F)
PI Eligibility: No
Drive is formatted for PI information: No
PI: No PI
Port-0 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Port-1 :
Port status: Active
Port's Linkspeed: 6.0Gb/s
Drive has flagged a S.M.A.R.T alert : No
Exit Code: 0x00