SlideShare una empresa de Scribd logo
1 de 6
Descargar para leer sin conexión
Chapter 10
Measurement of hydrogen ion concentration (pH)
1. General
pH is a way of expressing the hydrogen ion concentration in water. It is related to the
acidic or alkaline nature of water. Consideration of hydrogen ion concentration is important
in almost all uses of water. In particular, pH balance is important in maintaining desirable
aquatic ecological conditions in natural waters. pH is also maintained at various levels for
efficient operation of water and wastewater treatment systems such as coagulation,
disinfecting, softening, anaerobic decomposition of wastes, etc. The pH of most natural
waters lies between 6.5 and 8.
2. The pH scale
Pure water dissociates to yield 10"7
moles/L of H+
at 25 °C:
H 2 0 ~ H +
+ 0 H " (1)
Since water dissociates to produce one OH" ion for each H+
ion, it is obvious that 10"7
OH"
ions are produced simultaneously.
The product of [H+
] and [OH"] always remains constant. When the value for one of the
species changes the other also changes accordingly.
[H+
] x [OH] = 10"14
(2)
The large bracket sign, [ ], indicates molar concentration.
The concentration of H+
ions can be increased when compounds are added which release
H+
ions such as H2SO4:
H2SO4—• 2H+
+ S04
2
" (3)
Or preferentially combine with OH" ions when added to water, such as FeCl3.
FeCI3 + 3H2 0 —• Fe(OH)3 + 3H+
+ 3CI" (4)
Note that in either case the product of /H+
7and [OH"] ions remains constant at 10"14
Likewise the concentration of H+
ions can be decreased when compounds are added
which release OH" ions, such as NaOH, or preferentially combine with H+
ions, such as
Na2C03.
Expression of the molar concentration of hydrogen ions is rather cumbersome because of
the extremely small values and large variations. To overcome this difficulty, the
concentration is expressed in terms of pH value, which is negative logarithm of the
concentration in moles/L.
pH = - log [H+
] (5)
or [H+
] = 10pH
(6)
Thus the pH value of a sample of water containing 10"7 5
moles/L H+
is 7.5.
Since the product of [H+
] and [OH"] is always a constant, Eq. (2) becomes
log[H+
] +log[OH"]= -14
Or -log[H+
] - log [OH1 = +14
The pH scale is usually represented as ranging from 0 to 14, with pH 7 at 25 °C
representing neutrality. Acid conditions increase as pH values decrease and alkaline
conditions increase as pH values increase.
Acid range Neutral Alkaline range
1 2 3 4 5 6 7 8 9 10 11 12 13 14
3. Calculating pH
Example calculation
Calculate the pH value for the following cases:
A: [H+
]= a.0.0001
b.0.00005 and
B: [OH"] a 10"8
b. 0.00005 and
c.0.00001
A: [H+
} a. 0.0001
A. 0.00005
pH= -log 10"3
=3
pH= -log 0.00005= -log (5 x10"5
)= - 0.7 +5=4.3
B:[OH"] a. 10"8
b. 0.00005
c. 0.00001
[H+
] x 10"8
= 10"14
, or [H+
] =10"6
Therefore pH=6
—log[H+
]—log [OH"] =14
Therefore pH=14-4.3 =9.7
pH=14 + Iog10"5
=14- 5 =9
4. pH indicators
A number of naturally occurring or synthetic organic compounds undergo definite colour
changes in well-defined pH ranges. A number of indicators that are useful for various pH
ranges are listed in Table 1. The indicators assume different hues within the specified pH
range. These are used as liquid solutions or some as pH papers. The change in colour
occurs over a wide range of pH change and therefore pH value cannot be measured
accurately. Further, the turbidity and colour of the sample may cause interference.
Table 1
Indicator Acid colour Base colour pH
range
Methyl orange Red Yellow orange 3.1-4.6
Methyl red Red Yellow 4.4-6.2
Litmus Red Blue 4.5-8.3
Thymol blue Yellow Blue 8.0-9.6
Phenolphthalein Colourless Pink 8.2-9.8
Alizarin yellow Yellow Lilac 10.1-
11.1
5. pH meter
The use of colour indicators for pH measurements has, to some extent, been superseded
by development of glass electrode. pH meters employing glass-indicating electrodes and
saturated calomel reference electrodes are now commonly used. Such meters are capable
of measuring pH within + 0.1 pH unit. The electrodes, connected to the pH meters are
immersed in the sample and the meter measures the potential developed at the glass
electrode due to hydrogen ion concentration in the sample and displays it directly in pH
units. The pH meters are also equipped with a temperature-compensation adjustment.
The electrodes should be carefully handled and should not be scratched by butting against
the sides of the beaker containing the sample. Follow the manufacturer's instructions for
their care during storage and use. For short-term storage, the glass electrode may be left
immersed in pH 4 buffer solution., Saturated KCI is preferred for the reference electrode.
The glass electrode needs to be soaked in water for at least 12 hours before it is used for
pH measurement.
Buffer solutions & instrument calibration
pH meters have to be calibrated against solutions of known pH values. Standard buffers
are used for this purpose. Buffers are solutions of chemicals of known pH which do not
change their pH value upon dilution and resist change of pH when small amounts of acid
or alkali are added to them. Buffer solutions usually contain mixtures of weak acids and
their salts (conjugate bases) or weak bases and their salts (conjugate acids). Buffer has
importance for life forms that usually can survive only within a narrow pH range. Table 2
gives the composition of some commonly used buffers. Buffers of different pH values are
also available commercially.
Table 2 Buffer solutions of known pH
S. No Buffer solution pH at
25°C
Amount of salt to be dissolved in
1000 ml freshly boiled and cooled
and cooled distilled water
1. 0.05 M potassium hydrogen phthalate 4.00 10.12 g KHC8H404
2. 0.025 M potassium dihydrogen
phosphate + 0.025 M disodium
hydrogen phosphate
6.86 3.387 g KH2P04 and 3.533 g Na2HP04
3. 0.01 M sodium borate decahydrate 9.18 3.80 g Na2B407.10 H2 0
It is a good practice to calibrate the pH meter using two buffers. After calibrating with an
initial buffer, use a second buffer within 2 pH units of the sample pH.
OPERATION OF THE pH METER
How to measure the pH
1. Connect the pH electrode & temperature sensor to the measuring instrument.
2. Press the on/off Key.(display test appears briefly on the display)
3. Select pH value or redox voltage (mv) with <M>.
4. Immerse the pH electrode in water sample .
5. Press <AR>to switch on the drift control. Wait until measured value is stable and AR
stops flashing.
6. To cancel auto read at any time press <Run/Enter>.
Storing the data
1.Press <STO>Key in the measuring mode(display No. with the number of the next free
memory location.
2. Press <Run/Enter>.
3. Enter the Identification number with < V> <A>.
4. Terminate the save with <Run/Enter>.
How to see data memory
1. Press the <RCL> key in the measuring mode.(display Sto disp)
2. Press <Run/Enter>key (display number at which data store)
3. Press <Run/Enter>key(display identification number)
4. Press <Run/Enter>key (display day .month)
5. Press <Run/Enter>key (display time)
6. Press <M>key to return in measuring mode.
Calibration
1. The pH electrode to the measuring instrument.
2. Press the <Cal>key repeatedly untill the display Ct1 and the function display Auto
Cal TEC appears. The sensor symbol displays the evaluation of the last calibration.
3. Immerse the pH electrode in to the first buffer solution (pH-7.0)
4. Press <Run/Enter>key.(the auto read measurement begins. If the measured value
is stable, Ct2 appears.
Note:--At this point, the auto cal TEC calibration can be terminated with <M>.
1. Immerse the two pH electrode in the second buffer solution to continue.
2. Press <Run/Enter>key(the auto read measurement begins.) If the measured value
is stable, the instrument displays the value of the slope and the evaluation of the
two point calibration.
3. Press<Run/Enter>key.(the instrument displays the value of the asymmetry)
4. Switch to the measuring mode with<M>.
5. To set calibration interval, while pressing the <M>key, press <ON/OFF>Key.(display
CAL disp)
6. Press <Run/Enter>key.(display time of calibration display)
7. Set the interval of Calibration with <A > <V >.
Precautions
1. Always keep the electrode wet(with electrolyte in the cap of electrode),if you use it
after 2 or 3 days interval.
2. Keep it in ordinary water if you use continuously.
3. Clean properly with absorbent paper before and after use.
4. Need to Calibrate after a fixed interval.

Más contenido relacionado

La actualidad más candente

Preparing a Standard Solution
Preparing  a Standard SolutionPreparing  a Standard Solution
Preparing a Standard Solution
sweemoi khor
 

La actualidad más candente (20)

Buffers
BuffersBuffers
Buffers
 
PH meter
PH meterPH meter
PH meter
 
Preparing a Standard Solution
Preparing  a Standard SolutionPreparing  a Standard Solution
Preparing a Standard Solution
 
pH and pH meter
pH and pH meterpH and pH meter
pH and pH meter
 
Most probable number (MPN) method
Most probable number (MPN) method Most probable number (MPN) method
Most probable number (MPN) method
 
Ph meter
Ph meterPh meter
Ph meter
 
Preparation of standard, normal and molar solutions
Preparation of standard, normal and molar solutionsPreparation of standard, normal and molar solutions
Preparation of standard, normal and molar solutions
 
Ph scale
Ph scalePh scale
Ph scale
 
Measurement of Hydrogen Ion Concentration (pH)
Measurement of Hydrogen Ion Concentration (pH)Measurement of Hydrogen Ion Concentration (pH)
Measurement of Hydrogen Ion Concentration (pH)
 
Calibration of glassware
Calibration of glasswareCalibration of glassware
Calibration of glassware
 
pH indicator
pH indicatorpH indicator
pH indicator
 
pH
pHpH
pH
 
pH meter
pH meterpH meter
pH meter
 
Solutions preparation
Solutions preparationSolutions preparation
Solutions preparation
 
Lab 2 disk diffusion testing
Lab 2 disk diffusion testingLab 2 disk diffusion testing
Lab 2 disk diffusion testing
 
Capsule staining
Capsule stainingCapsule staining
Capsule staining
 
Indole test
Indole testIndole test
Indole test
 
The Streak plate method,
 The Streak plate method,  The Streak plate method,
The Streak plate method,
 
Analytical balance
Analytical balanceAnalytical balance
Analytical balance
 
Normality,Molality,Molarity,Mole fraction,Formality
Normality,Molality,Molarity,Mole fraction,FormalityNormality,Molality,Molarity,Mole fraction,Formality
Normality,Molality,Molarity,Mole fraction,Formality
 

Similar a Measurement of hydrogen ion concentration (p h)

AC lab 7 cover and report
AC lab 7 cover and reportAC lab 7 cover and report
AC lab 7 cover and report
Alex Stinnett
 
P h technical handbook
P h technical handbookP h technical handbook
P h technical handbook
Abegail Ayaso
 

Similar a Measurement of hydrogen ion concentration (p h) (20)

Introduction to-ph
Introduction to-phIntroduction to-ph
Introduction to-ph
 
Table top microprocessor p h meters
Table top microprocessor p h metersTable top microprocessor p h meters
Table top microprocessor p h meters
 
pH meter
pH meterpH meter
pH meter
 
Potentio lab report
Potentio lab reportPotentio lab report
Potentio lab report
 
Drilling Fluid Engineering-PH Lab-Drilling Lab#9.pdf
Drilling Fluid Engineering-PH Lab-Drilling Lab#9.pdfDrilling Fluid Engineering-PH Lab-Drilling Lab#9.pdf
Drilling Fluid Engineering-PH Lab-Drilling Lab#9.pdf
 
Volumetric Analysis by Dr. A. Amsavel
Volumetric Analysis by  Dr. A. AmsavelVolumetric Analysis by  Dr. A. Amsavel
Volumetric Analysis by Dr. A. Amsavel
 
Volumetric Analysis By Dr.A. Amsavel
Volumetric Analysis By Dr.A. AmsavelVolumetric Analysis By Dr.A. Amsavel
Volumetric Analysis By Dr.A. Amsavel
 
1. Acid- Base Titration.ppt
1. Acid- Base Titration.ppt1. Acid- Base Titration.ppt
1. Acid- Base Titration.ppt
 
Ph,buffers,balance
Ph,buffers,balancePh,buffers,balance
Ph,buffers,balance
 
Chemistry Lab Report 2
Chemistry Lab Report 2Chemistry Lab Report 2
Chemistry Lab Report 2
 
Analisis de agua merck (1)
Analisis de agua merck (1)Analisis de agua merck (1)
Analisis de agua merck (1)
 
Analytical Measurements: Troubleshooting, Maintenance and the Future
Analytical Measurements:  Troubleshooting, Maintenance and the FutureAnalytical Measurements:  Troubleshooting, Maintenance and the Future
Analytical Measurements: Troubleshooting, Maintenance and the Future
 
pH - MEASUREMENT .ppt
pH - MEASUREMENT .pptpH - MEASUREMENT .ppt
pH - MEASUREMENT .ppt
 
Manish ppt
Manish pptManish ppt
Manish ppt
 
AC lab 7 cover and report
AC lab 7 cover and reportAC lab 7 cover and report
AC lab 7 cover and report
 
P h technical handbook
P h technical handbookP h technical handbook
P h technical handbook
 
UNIT 5TH - pH, buffers and Isotonic solutions
UNIT 5TH - pH, buffers and Isotonic solutionsUNIT 5TH - pH, buffers and Isotonic solutions
UNIT 5TH - pH, buffers and Isotonic solutions
 
Exp 1 (A)
Exp 1 (A)Exp 1 (A)
Exp 1 (A)
 
Digital pH Meters Table Model by ACMAS Technologies Pvt Ltd.
Digital pH Meters Table Model by ACMAS Technologies Pvt Ltd.Digital pH Meters Table Model by ACMAS Technologies Pvt Ltd.
Digital pH Meters Table Model by ACMAS Technologies Pvt Ltd.
 
eelt lab 2 report.docx
eelt lab 2 report.docxeelt lab 2 report.docx
eelt lab 2 report.docx
 

Más de ECRD2015

Más de ECRD2015 (20)

Pollution control in small and medium scale industry
Pollution control in small and medium scale industryPollution control in small and medium scale industry
Pollution control in small and medium scale industry
 
Indoor air quality
Indoor air qualityIndoor air quality
Indoor air quality
 
Air pollution control
Air pollution controlAir pollution control
Air pollution control
 
Vehicular Pollution Management
Vehicular Pollution ManagementVehicular Pollution Management
Vehicular Pollution Management
 
Strategy of control of urban air pollution
Strategy of control of urban air pollutionStrategy of control of urban air pollution
Strategy of control of urban air pollution
 
Spectrophotometer meter
Spectrophotometer meterSpectrophotometer meter
Spectrophotometer meter
 
Some critical facets in air pollution
Some critical facets in air pollutionSome critical facets in air pollution
Some critical facets in air pollution
 
Slm_1
Slm_1Slm_1
Slm_1
 
Shop floor monitoring
Shop floor monitoringShop floor monitoring
Shop floor monitoring
 
Quality assurance and quality control
Quality assurance and quality controlQuality assurance and quality control
Quality assurance and quality control
 
Preventive measures for occupational
Preventive measures for occupationalPreventive measures for occupational
Preventive measures for occupational
 
Pm10 measmnt
Pm10 measmntPm10 measmnt
Pm10 measmnt
 
Ozone
OzoneOzone
Ozone
 
Nitrogen oxide monitoring
Nitrogen oxide monitoringNitrogen oxide monitoring
Nitrogen oxide monitoring
 
Monitoring of inorganic ions
Monitoring of inorganic ionsMonitoring of inorganic ions
Monitoring of inorganic ions
 
Minutes of brain storming session on air pollution load carrying capacity of ...
Minutes of brain storming session on air pollution load carrying capacity of ...Minutes of brain storming session on air pollution load carrying capacity of ...
Minutes of brain storming session on air pollution load carrying capacity of ...
 
Measurement of respirable suspended pm10
Measurement of respirable suspended pm10Measurement of respirable suspended pm10
Measurement of respirable suspended pm10
 
Maintenance
MaintenanceMaintenance
Maintenance
 
Maintenance of high volume
Maintenance of high volumeMaintenance of high volume
Maintenance of high volume
 
Industrial emission control techniques
Industrial emission control techniquesIndustrial emission control techniques
Industrial emission control techniques
 

Último

E Waste Management
E Waste ManagementE Waste Management
E Waste Management
Dr. Salem Baidas
 
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdfTraining Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
Basel Ahmed
 
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
rajputriyana310
 

Último (20)

VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
VVIP Pune Call Girls Vishal Nagar WhatSapp Number 8005736733 With Elite Staff...
 
DENR EPR Law Compliance Updates April 2024
DENR EPR Law Compliance Updates April 2024DENR EPR Law Compliance Updates April 2024
DENR EPR Law Compliance Updates April 2024
 
Get Premium Hoskote Call Girls (8005736733) 24x7 Rate 15999 with A/c Room Cas...
Get Premium Hoskote Call Girls (8005736733) 24x7 Rate 15999 with A/c Room Cas...Get Premium Hoskote Call Girls (8005736733) 24x7 Rate 15999 with A/c Room Cas...
Get Premium Hoskote Call Girls (8005736733) 24x7 Rate 15999 with A/c Room Cas...
 
Proposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
Proposed Amendments to Chapter 15, Article X: Wetland Conservation AreasProposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
Proposed Amendments to Chapter 15, Article X: Wetland Conservation Areas
 
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Jejuri Call Me 7737669865 Budget Friendly No Advance Booking
 
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Ramtek Call Me 7737669865 Budget Friendly No Advance Booking
 
E Waste Management
E Waste ManagementE Waste Management
E Waste Management
 
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Budhwar Peth Call Me 7737669865 Budget Friendly No Advance Booking
 
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
VIP Model Call Girls Hadapsar ( Pune ) Call ON 8005736733 Starting From 5K to...
 
Kondhwa ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
Kondhwa ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...Kondhwa ( Call Girls ) Pune  6297143586  Hot Model With Sexy Bhabi Ready For ...
Kondhwa ( Call Girls ) Pune 6297143586 Hot Model With Sexy Bhabi Ready For ...
 
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
The Most Attractive Pune Call Girls Shirwal 8250192130 Will You Miss This Cha...
 
VIP Model Call Girls Viman Nagar ( Pune ) Call ON 8005736733 Starting From 5K...
VIP Model Call Girls Viman Nagar ( Pune ) Call ON 8005736733 Starting From 5K...VIP Model Call Girls Viman Nagar ( Pune ) Call ON 8005736733 Starting From 5K...
VIP Model Call Girls Viman Nagar ( Pune ) Call ON 8005736733 Starting From 5K...
 
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance BookingCall Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
Call Girls Pune Airport Call Me 7737669865 Budget Friendly No Advance Booking
 
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdfTraining Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
Training Of Trainers FAI Eng. Basel Tilapia Welfare.pdf
 
Types of Pollution Powerpoint presentation
Types of Pollution Powerpoint presentationTypes of Pollution Powerpoint presentation
Types of Pollution Powerpoint presentation
 
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
VVIP Pune Call Girls Moshi WhatSapp Number 8005736733 With Elite Staff And Re...
 
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
Call Girls In Bloom Boutique | GK-1 ☎ 9990224454 High Class Delhi NCR 24 Hour...
 
$ Love Spells 💎 (310) 882-6330 in Pennsylvania, PA | Psychic Reading Best Bla...
$ Love Spells 💎 (310) 882-6330 in Pennsylvania, PA | Psychic Reading Best Bla...$ Love Spells 💎 (310) 882-6330 in Pennsylvania, PA | Psychic Reading Best Bla...
$ Love Spells 💎 (310) 882-6330 in Pennsylvania, PA | Psychic Reading Best Bla...
 
CSR_Tested activities in the classroom -EN
CSR_Tested activities in the classroom -ENCSR_Tested activities in the classroom -EN
CSR_Tested activities in the classroom -EN
 
Booking open Available Pune Call Girls Parvati Darshan 6297143586 Call Hot I...
Booking open Available Pune Call Girls Parvati Darshan  6297143586 Call Hot I...Booking open Available Pune Call Girls Parvati Darshan  6297143586 Call Hot I...
Booking open Available Pune Call Girls Parvati Darshan 6297143586 Call Hot I...
 

Measurement of hydrogen ion concentration (p h)

  • 1. Chapter 10 Measurement of hydrogen ion concentration (pH) 1. General pH is a way of expressing the hydrogen ion concentration in water. It is related to the acidic or alkaline nature of water. Consideration of hydrogen ion concentration is important in almost all uses of water. In particular, pH balance is important in maintaining desirable aquatic ecological conditions in natural waters. pH is also maintained at various levels for efficient operation of water and wastewater treatment systems such as coagulation, disinfecting, softening, anaerobic decomposition of wastes, etc. The pH of most natural waters lies between 6.5 and 8. 2. The pH scale Pure water dissociates to yield 10"7 moles/L of H+ at 25 °C: H 2 0 ~ H + + 0 H " (1) Since water dissociates to produce one OH" ion for each H+ ion, it is obvious that 10"7 OH" ions are produced simultaneously. The product of [H+ ] and [OH"] always remains constant. When the value for one of the species changes the other also changes accordingly. [H+ ] x [OH] = 10"14 (2) The large bracket sign, [ ], indicates molar concentration. The concentration of H+ ions can be increased when compounds are added which release H+ ions such as H2SO4: H2SO4—• 2H+ + S04 2 " (3) Or preferentially combine with OH" ions when added to water, such as FeCl3. FeCI3 + 3H2 0 —• Fe(OH)3 + 3H+ + 3CI" (4) Note that in either case the product of /H+ 7and [OH"] ions remains constant at 10"14 Likewise the concentration of H+ ions can be decreased when compounds are added which release OH" ions, such as NaOH, or preferentially combine with H+ ions, such as Na2C03. Expression of the molar concentration of hydrogen ions is rather cumbersome because of
  • 2. the extremely small values and large variations. To overcome this difficulty, the concentration is expressed in terms of pH value, which is negative logarithm of the concentration in moles/L. pH = - log [H+ ] (5) or [H+ ] = 10pH (6) Thus the pH value of a sample of water containing 10"7 5 moles/L H+ is 7.5. Since the product of [H+ ] and [OH"] is always a constant, Eq. (2) becomes log[H+ ] +log[OH"]= -14 Or -log[H+ ] - log [OH1 = +14 The pH scale is usually represented as ranging from 0 to 14, with pH 7 at 25 °C representing neutrality. Acid conditions increase as pH values decrease and alkaline conditions increase as pH values increase. Acid range Neutral Alkaline range 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3. Calculating pH Example calculation Calculate the pH value for the following cases: A: [H+ ]= a.0.0001 b.0.00005 and B: [OH"] a 10"8 b. 0.00005 and c.0.00001 A: [H+ } a. 0.0001 A. 0.00005 pH= -log 10"3 =3 pH= -log 0.00005= -log (5 x10"5 )= - 0.7 +5=4.3 B:[OH"] a. 10"8 b. 0.00005 c. 0.00001 [H+ ] x 10"8 = 10"14 , or [H+ ] =10"6 Therefore pH=6 —log[H+ ]—log [OH"] =14 Therefore pH=14-4.3 =9.7 pH=14 + Iog10"5 =14- 5 =9
  • 3. 4. pH indicators A number of naturally occurring or synthetic organic compounds undergo definite colour changes in well-defined pH ranges. A number of indicators that are useful for various pH ranges are listed in Table 1. The indicators assume different hues within the specified pH range. These are used as liquid solutions or some as pH papers. The change in colour occurs over a wide range of pH change and therefore pH value cannot be measured accurately. Further, the turbidity and colour of the sample may cause interference. Table 1 Indicator Acid colour Base colour pH range Methyl orange Red Yellow orange 3.1-4.6 Methyl red Red Yellow 4.4-6.2 Litmus Red Blue 4.5-8.3 Thymol blue Yellow Blue 8.0-9.6 Phenolphthalein Colourless Pink 8.2-9.8 Alizarin yellow Yellow Lilac 10.1- 11.1 5. pH meter The use of colour indicators for pH measurements has, to some extent, been superseded by development of glass electrode. pH meters employing glass-indicating electrodes and saturated calomel reference electrodes are now commonly used. Such meters are capable of measuring pH within + 0.1 pH unit. The electrodes, connected to the pH meters are immersed in the sample and the meter measures the potential developed at the glass electrode due to hydrogen ion concentration in the sample and displays it directly in pH units. The pH meters are also equipped with a temperature-compensation adjustment. The electrodes should be carefully handled and should not be scratched by butting against the sides of the beaker containing the sample. Follow the manufacturer's instructions for their care during storage and use. For short-term storage, the glass electrode may be left immersed in pH 4 buffer solution., Saturated KCI is preferred for the reference electrode. The glass electrode needs to be soaked in water for at least 12 hours before it is used for pH measurement. Buffer solutions & instrument calibration pH meters have to be calibrated against solutions of known pH values. Standard buffers are used for this purpose. Buffers are solutions of chemicals of known pH which do not
  • 4. change their pH value upon dilution and resist change of pH when small amounts of acid or alkali are added to them. Buffer solutions usually contain mixtures of weak acids and their salts (conjugate bases) or weak bases and their salts (conjugate acids). Buffer has importance for life forms that usually can survive only within a narrow pH range. Table 2 gives the composition of some commonly used buffers. Buffers of different pH values are also available commercially. Table 2 Buffer solutions of known pH S. No Buffer solution pH at 25°C Amount of salt to be dissolved in 1000 ml freshly boiled and cooled and cooled distilled water 1. 0.05 M potassium hydrogen phthalate 4.00 10.12 g KHC8H404 2. 0.025 M potassium dihydrogen phosphate + 0.025 M disodium hydrogen phosphate 6.86 3.387 g KH2P04 and 3.533 g Na2HP04 3. 0.01 M sodium borate decahydrate 9.18 3.80 g Na2B407.10 H2 0 It is a good practice to calibrate the pH meter using two buffers. After calibrating with an initial buffer, use a second buffer within 2 pH units of the sample pH.
  • 5. OPERATION OF THE pH METER How to measure the pH 1. Connect the pH electrode & temperature sensor to the measuring instrument. 2. Press the on/off Key.(display test appears briefly on the display) 3. Select pH value or redox voltage (mv) with <M>. 4. Immerse the pH electrode in water sample . 5. Press <AR>to switch on the drift control. Wait until measured value is stable and AR stops flashing. 6. To cancel auto read at any time press <Run/Enter>. Storing the data 1.Press <STO>Key in the measuring mode(display No. with the number of the next free memory location. 2. Press <Run/Enter>. 3. Enter the Identification number with < V> <A>. 4. Terminate the save with <Run/Enter>. How to see data memory 1. Press the <RCL> key in the measuring mode.(display Sto disp) 2. Press <Run/Enter>key (display number at which data store) 3. Press <Run/Enter>key(display identification number) 4. Press <Run/Enter>key (display day .month) 5. Press <Run/Enter>key (display time) 6. Press <M>key to return in measuring mode.
  • 6. Calibration 1. The pH electrode to the measuring instrument. 2. Press the <Cal>key repeatedly untill the display Ct1 and the function display Auto Cal TEC appears. The sensor symbol displays the evaluation of the last calibration. 3. Immerse the pH electrode in to the first buffer solution (pH-7.0) 4. Press <Run/Enter>key.(the auto read measurement begins. If the measured value is stable, Ct2 appears. Note:--At this point, the auto cal TEC calibration can be terminated with <M>. 1. Immerse the two pH electrode in the second buffer solution to continue. 2. Press <Run/Enter>key(the auto read measurement begins.) If the measured value is stable, the instrument displays the value of the slope and the evaluation of the two point calibration. 3. Press<Run/Enter>key.(the instrument displays the value of the asymmetry) 4. Switch to the measuring mode with<M>. 5. To set calibration interval, while pressing the <M>key, press <ON/OFF>Key.(display CAL disp) 6. Press <Run/Enter>key.(display time of calibration display) 7. Set the interval of Calibration with <A > <V >. Precautions 1. Always keep the electrode wet(with electrolyte in the cap of electrode),if you use it after 2 or 3 days interval. 2. Keep it in ordinary water if you use continuously. 3. Clean properly with absorbent paper before and after use. 4. Need to Calibrate after a fixed interval.