siemens.com/energy/steamturbines
Pre-designed Steam Turbines
The comprehensive product range up to 12 megawatts
Industrial Power
Scan the
QR code with
the QR code
reader in
your mobile!
A Full Range of World-class
Industrial Steam Turbines
Whatever your need for a prime mover, Siemens can
provide you with versatile, reliable and proven indus-
trial steam turbines. The world leader in steam turbine
technology, with over 100 years of experience and
continuous development, and a fleet of more than
20,000 installed turbines, we are a prime partner for
your business.
Siemens offers a comprehensive range of pre-designed
steam turbines up to 12 MW. These innovative but eco-
nomical machines have a simple modular design which
facilitates optimization of performance for the required
application. For optimal configuration, we have different
but fully compatible design series to draw upon, enabling
us to match your needs as exactly as possible.
For our range of industrial steam turbines with a power
output from 2 MW up to 250 MW and for large steam tur-
bines from 250 MW to 1,200 MW, we offer separate port-
folio brochures.
Our predesigned steam turbines meet customer require-
ments for economic installation and operation as well as
providing excellent flexibility for complex industrial pro-
cesses. So, whether you need a generator drive for power
generation or a mechanical drive for compressors, blowers
and pumps, just talk to us and together we can select the
turbine or turboset which is optimally suited to your
needs.
Of course we strictly adhere to the guidelines laid down in
the quality standards ISO 9001 and ISO 14001. Not only
the steam turbines, but also associated field-proven high-
tech products are available from the Siemens range. These
include generators, instrumentation and controls, as well
as auxiliary and ancillary systems.
Type
1 2 3 4 5 6 7 8 9 10 11 12
Output (MW)Steam
parameters
(up to)
SST-010	 70 bar, 5 °C (Gas)
SST-040	 40 bar, 400 °C
SST-050	 101 bar, 500 °C
SST-060	 131 bar, 530 °C
SST-110	 131 bar, 530 °C
SST-111	 131 bar, 530 °C
Pre-designed steam turbines
The comprehensive Siemens product range up to 12 megawatts
SST-040
(formerly known as AFA 3.5)
up to 300 kW
The SST-040 is a single-stage impulse turbine. The favorably priced
turbine was designed as a generator drive for the 75-300 kW power
range and can be used in small combined heat and power (CHP)
plants, in decentralized solar facilities as well as for waste-heat re-
covery, e.g. used behind gas engines and biogas engines or for the
utilization of residual process steam.
Technical data
n	 Power output up to 300 kW
n	 Inlet pressure up to 40 bar(a)/580 psi
n	 Inlet temperature dry saturated steam up to 400 °C/750 °F
n	 Speed acc. to driven machine
n	 Exhaust pressure: from 0.1 bar (a)/1.5 psi condensation
backpressure
Typical dimensions
Length 2.5 m/8.2 ft*
Width 1.5 m/4.9 ft*
Height 2 m/6.5 ft*
Features
n	 Backpressure or condensing type
n	 Package unit design, oil unit integrated in base frame
n	 Extremely small and compact design, total weight only 4,500 kg*
n	 Only minimal foundation work required
n	 Largely maintenance-free due to stalwart, robust construction
n	 High availability thanks to resilient and sure technology
n	 Quick start without preheating of the turbine
n	 Favorably priced thanks to proven components
n	 Quick installation and commissioning
*complete turbine-generator set
SST-010
(formerly known as EPM = Expansion Power Module)
up to 110 kW
The SST-010 is a compact turbogenerator designed to expand natu-
ral gas in pressure regulating stations as a direct driving turbine in
pipe installation.
Technical data
n	 Power output up to 110 kW
n	 Gas pressure up to 70 bar(a)/1,015 psi
n	 Gas flow rates up to 15,000 m3
/h/530,000 ft3
/h
n	 Exhaust gas pressure up to 25 bar(a)/363 psi
n	 Turbine wheel diameter 400 mm/15.75 in
Typical dimensions
Length 1.2 m/4 ft
Width 0.8 m/2.6 ft
Height 0.9 m/3 ft
Features
n	 Low-maintenance because of the simple design
n	 Extremely failure safe
n	 Quick-start compatible
n	 Casing flanged directly into the gas pipeline
n	 ATEX approved
SST-060
(formerly known as AFA, CFA or CFR series)
up to 6 MW
The SST-060 stand out by their rugged design and renowned reli-
ability even under the most severe operating conditions. They are
ideal for saturated steam service. Their suitability for use as conden-
sation or back-pressure turbines in combination with various inte-
gral gears modules opens up a broad application range.
Technical data
n	 Power output up to 6 MW
n	 Inlet pressure up to 131 bar(a)/1,900 psi
n	 Inlet temperature dry saturated steam up to 530 °C/985 °F
n	 Speed acc. to driven machine
n	 Exhaust pressure: back pressure up to 29 bar(a)/420 psi or vacuum
Typical dimensions
Length 1.5 m/4.9 ft*
Width 2.5 m/8.2 ft*
Height 2.5 m/8.2 ft*
Features
n	 Backpressure or condensing type
n	 Package unit design
n	 Oil unit integrated in base frame
n	 Nozzle group control valves available
n	 Quick-start without pre-heating
n	 Tailor made
n	 Meet requirements of API 611/612**
n	 ATEX version available
n	 Suitable for ORC (Organic Rankine Cycle)
n	 Suitable for gas expansion
*turbine only
**if overhung design and integral gear is accepted
SST-050
(formerly known as AF or BF series)
up to 750 kW
The SST-050 is a single-stage, backpressure steam turbine in which
the flow passes axially through the blading. It is mainly used as a
power source for pumps or fans and especially as a stand-by unit
with quick-start capability.
Technical data
n	 Power output up to 750 kW
n	 Inlet pressure up to 101 bar(a)/1,465 psi
n	 Inlet temperature dry saturated steam up to 500 °C/930 °F
n	 Speed acc. to driven machine
n	 Exhaust pressure: back pressure up to 11 bar(a)/160 psi
Typical dimensions
Length 1 m/3.3 ft*
Width 1 m/3.3 ft*
Height 1.3 m/4.3 ft*
Features
n	 Low-maintenance because of the simple design
n	 Extremely failure safe
n	 Quick-start compatible
n	 Turbine with integral oil supply
n	 Meet requirements of API 611/612**
n	 ATEX version available
*turbine only
**if overhung design and integral gear is accepted
SST-111
up to 12 MW
The SST-111 is a dual or triple casing steam turbine with an integrated
gearbox, designed for flexible operation and high efficiency. The
multi-casing design allows for up to two controlled extractions as
well as for operation on different steam supply systems.
Technical data
n	 Power output up to 12 MW
n	 Inlet pressure up to 131 bar(a)/1,900 psi
n	 Inlet temperature up to 530 °C/985 °F
n	 Exhaust pressure: up to 0.06 bar (a)/8.7 psi condensation
Typical dimensions
Length approx. 8 m/26.2 ft (incl. generator)
Width 4 m/13.1 ft
Height 4 m/13.1 ft
Features
n	 Condensing type
n	 Package unit design
n	 Oil unit integrated in base frame
n	 Nozzle group control valves available
n	 Quick-start without pre-heating
n	 Extremely compact construction
n	 Pressure controlled extraction
n	 High pressure/low pressure applications
n	 ATEX version available
n	 Reheat possible
SST-110
(formerly known as TWIN version)
up to 7 MW
The SST-110 provides highest cost efficiency and high performance.
It allows to reduce high heat gradients while providing a controlled
extraction capability. The SST-110 is a dual casing turbine on one
gearbox which can run on different steam lines.
Technical data
n	 Power output up to 7 MW
n	 Inlet pressure up to 131 bar(a)/1,900 psi
n	 Inlet temperature dry saturated steam up to 530 °C/985 °F
n	 Speed acc. to driven machine
n	 Exhaust pressure: back pressure or vacuum
Typical dimensions
Length approx. 6 m/20 ft (incl. generator)
Width 2.8 m/9.2 ft
Height 3.2 m/10.5 ft
Features
n	 Backpressure, extraction or condensing type
n	 Package unit design
n	 Oil unit integrated in base frame
n	 Nozzle group control valves available
n	 Quick-start without pre-heating
n	 Extremely compact construction
n	 Pressure controlled extraction
n	 High pressure/low pressure applications
n	 Meet requirements of API 611/612*
n	 ATEX version available
n	 Suitable for ORC (Organic Rankine Cycle)
n	 Suitable for gas expansion
*if overhung design and integral gear is accepted
Fields of application
Siemens industrial steam turbines ­increase the
efficiency of power ­generation and improve the
profit­ability of industrial applications.
Industries
n	 Chemistry
n	 Food  Beverage
n	 Independent power producers
n	 Manufacturing industries, producers of pumps
and compressors
n	 Petrochemistry/Refineries
n	 Smelters/Steel
n	 Sugar/Palmoil
n	 Utilities
n	 Wood-working industry/Paper mills
Applications
n	 Biomass power plants
n	 Captive power plants
n	 Cogeneration/CHP
n	 Gas expansion
n	 Geothermal plants
n	 Heat-recovery
n	 Mechanical drives
n	 Ships/Offshore
n	 Solar thermal plants
n	 Waste incineration plants
Main advantages
n	 High efficiency
n	 High reliability/availability
n	 Customized proven solutions
n	 Compact design
n	 Simple installation and maintenance
Published by and copyright © 2013:
Siemens AG
Energy Sector
Freyeslebenstrasse 1
91058 Erlangen, Germany
Siemens AG
Energy Sector
Oil  Gas Division
Wolfgang-Reuter-Platz
47053 Duisburg, Germany
Siemens Energy Inc.
10730 Telge Road
Houston, Texas 77095, USA
For more information, please contact our
Customer Support Center.
Phone:	+49 180 524 70 00
Fax:	 +49 180 524 24 71
(Charges depending on provider)
e-mail:	support.energy@siemens.com
Oil  Gas Division
Order No. E50001-W4100-A100-V2-4A00
Printed in Germany
Dispo 34806, c4bs 7479
bdk 120175, P WS 0213.6
Printed on elementary chlorine-free
bleached paper.
All rights reserved.
Trademarks mentioned in this document are
the property of Siemens AG, its affiliates,
or their respective owners.
Subject to change without prior notice. The
information in this document contains general
descriptions of the technical options available,
which may not apply in all cases. The required
technical options should therefore be specified
in the contract.

Más contenido relacionado

La actualidad más candente

Project Report on Analysis of Boiler- Aditya
Project Report on Analysis of Boiler- AdityaProject Report on Analysis of Boiler- Aditya
Project Report on Analysis of Boiler- Aditya
Aditya Bhattacharjee
 
Thermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam BoilerThermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam Boiler
John Walter
 
Performance optimization of Forced Draft Fan of BBGS Unit # 1
Performance optimization of Forced Draft Fan of BBGS Unit # 1Performance optimization of Forced Draft Fan of BBGS Unit # 1
Performance optimization of Forced Draft Fan of BBGS Unit # 1
Saikat Halder
 

La actualidad más candente (20)

210 mw turbine cycle heat rate
210 mw turbine cycle heat rate210 mw turbine cycle heat rate
210 mw turbine cycle heat rate
 
210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance210 MW BHEL Turbine Cycle Heat Balance
210 MW BHEL Turbine Cycle Heat Balance
 
Combined Cycle Gas Turbine Power Plant Part 1
Combined Cycle Gas Turbine Power Plant Part 1Combined Cycle Gas Turbine Power Plant Part 1
Combined Cycle Gas Turbine Power Plant Part 1
 
Project Report on Analysis of Boiler- Aditya
Project Report on Analysis of Boiler- AdityaProject Report on Analysis of Boiler- Aditya
Project Report on Analysis of Boiler- Aditya
 
Super Critical Technology-Fundamental Concepts about Super Critical Technolog...
Super Critical Technology-Fundamental Concepts about Super Critical Technolog...Super Critical Technology-Fundamental Concepts about Super Critical Technolog...
Super Critical Technology-Fundamental Concepts about Super Critical Technolog...
 
Improve plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater controlImprove plant heat rate with feedwater heater control
Improve plant heat rate with feedwater heater control
 
Thermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam BoilerThermodynamic Design of a Fire-Tube Steam Boiler
Thermodynamic Design of a Fire-Tube Steam Boiler
 
Project ppt
Project pptProject ppt
Project ppt
 
Study and Analysis of Tube Failure in Water Tube boiler
Study and Analysis of Tube Failure in Water Tube boilerStudy and Analysis of Tube Failure in Water Tube boiler
Study and Analysis of Tube Failure in Water Tube boiler
 
Training report- Boiler and Thermal Plants.
Training report- Boiler and Thermal Plants.Training report- Boiler and Thermal Plants.
Training report- Boiler and Thermal Plants.
 
Report on Boilers at NTPC Ramagunadam
Report on  Boilers at NTPC RamagunadamReport on  Boilers at NTPC Ramagunadam
Report on Boilers at NTPC Ramagunadam
 
Super critical boiler
Super critical boilerSuper critical boiler
Super critical boiler
 
Feedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu VaidFeedwater heaters by Himanshu Vaid
Feedwater heaters by Himanshu Vaid
 
The reheat cycle
The reheat cycleThe reheat cycle
The reheat cycle
 
Ntpc (national thermal power corporation) sipat mechanical vocational trainin...
Ntpc (national thermal power corporation) sipat mechanical vocational trainin...Ntpc (national thermal power corporation) sipat mechanical vocational trainin...
Ntpc (national thermal power corporation) sipat mechanical vocational trainin...
 
Cmc philosophy
Cmc philosophyCmc philosophy
Cmc philosophy
 
Turbine cycle heat rate calculation
Turbine  cycle heat rate calculationTurbine  cycle heat rate calculation
Turbine cycle heat rate calculation
 
Performance optimization of Forced Draft Fan of BBGS Unit # 1
Performance optimization of Forced Draft Fan of BBGS Unit # 1Performance optimization of Forced Draft Fan of BBGS Unit # 1
Performance optimization of Forced Draft Fan of BBGS Unit # 1
 
Condenser performance test
Condenser performance testCondenser performance test
Condenser performance test
 
Boiler turbe failores
Boiler turbe failoresBoiler turbe failores
Boiler turbe failores
 

Destacado

Costos de operación y de produccion de energia de una turbina a vapor
Costos de operación y de produccion de energia de una turbina a vaporCostos de operación y de produccion de energia de una turbina a vapor
Costos de operación y de produccion de energia de una turbina a vapor
Nando Villanueva Paye
 
Turbine manufacturing process
Turbine manufacturing processTurbine manufacturing process
Turbine manufacturing process
physics101
 
Turbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
Turbine-Over-Hauling-Procedure - Siemens - Recommends BirkositTurbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
Turbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
Project Sales Corp
 

Destacado (18)

Siemens Steam Turbines 2MW-250MW
Siemens Steam Turbines 2MW-250MWSiemens Steam Turbines 2MW-250MW
Siemens Steam Turbines 2MW-250MW
 
steam turbine casing manufacture
steam turbine casing manufacturesteam turbine casing manufacture
steam turbine casing manufacture
 
Steam Turbine - biomass
Steam Turbine - biomassSteam Turbine - biomass
Steam Turbine - biomass
 
Применение блочно-модульных паровых турбин и турбодетандеров компании Siemens...
Применение блочно-модульных паровых турбин и турбодетандеров компании Siemens...Применение блочно-модульных паровых турбин и турбодетандеров компании Siemens...
Применение блочно-модульных паровых турбин и турбодетандеров компании Siemens...
 
Costos de operación y de produccion de energia de una turbina a vapor
Costos de operación y de produccion de energia de una turbina a vaporCostos de operación y de produccion de energia de una turbina a vapor
Costos de operación y de produccion de energia de una turbina a vapor
 
Tarining Report on Siemens
Tarining Report on SiemensTarining Report on Siemens
Tarining Report on Siemens
 
2ND SHORT PPT ON BHEL INTERNSHIP(BLOCK-3)(2014)
2ND SHORT PPT ON BHEL INTERNSHIP(BLOCK-3)(2014)2ND SHORT PPT ON BHEL INTERNSHIP(BLOCK-3)(2014)
2ND SHORT PPT ON BHEL INTERNSHIP(BLOCK-3)(2014)
 
Ge Steam Turbine Products
Ge Steam Turbine ProductsGe Steam Turbine Products
Ge Steam Turbine Products
 
Jacques Nader - Large Wind Turbine Blade Design Challenges and R&D Needs
Jacques Nader - Large Wind Turbine Blade Design Challenges and R&D NeedsJacques Nader - Large Wind Turbine Blade Design Challenges and R&D Needs
Jacques Nader - Large Wind Turbine Blade Design Challenges and R&D Needs
 
Steam turbine engineering india private limited company profile
Steam turbine engineering india private limited company profileSteam turbine engineering india private limited company profile
Steam turbine engineering india private limited company profile
 
Trends in Blade Technology and Changing R&D Needs Panel
Trends in Blade Technology and Changing R&D Needs PanelTrends in Blade Technology and Changing R&D Needs Panel
Trends in Blade Technology and Changing R&D Needs Panel
 
Performance of gas turbine power plant
Performance of gas turbine power plantPerformance of gas turbine power plant
Performance of gas turbine power plant
 
Steam Turbine Alignment
Steam Turbine AlignmentSteam Turbine Alignment
Steam Turbine Alignment
 
Steam turbine
Steam turbineSteam turbine
Steam turbine
 
Turbine manufacturing process
Turbine manufacturing processTurbine manufacturing process
Turbine manufacturing process
 
Turbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
Turbine-Over-Hauling-Procedure - Siemens - Recommends BirkositTurbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
Turbine-Over-Hauling-Procedure - Siemens - Recommends Birkosit
 
Bhel steam turbine manufacturing
Bhel steam turbine manufacturingBhel steam turbine manufacturing
Bhel steam turbine manufacturing
 
Turbine of the Power Plants Maintenance Replacement Engineering
Turbine of the Power Plants Maintenance Replacement EngineeringTurbine of the Power Plants Maintenance Replacement Engineering
Turbine of the Power Plants Maintenance Replacement Engineering
 

Similar a Siemens Steam Turbines 45kW-12MW

Industrial_Steam_Turbines_en.pdf
Industrial_Steam_Turbines_en.pdfIndustrial_Steam_Turbines_en.pdf
Industrial_Steam_Turbines_en.pdf
PABarbanegra
 
Industrial Steam Turbines Portfolio_EN
Industrial Steam Turbines Portfolio_ENIndustrial Steam Turbines Portfolio_EN
Industrial Steam Turbines Portfolio_EN
Fran Dubois
 
Pre-Designed_Turbocompressors
Pre-Designed_TurbocompressorsPre-Designed_Turbocompressors
Pre-Designed_Turbocompressors
Rohit Davidson
 
ceair presentation 2
ceair presentation 2ceair presentation 2
ceair presentation 2
David Pridham
 
New Star Plasma Brochure
New Star Plasma BrochureNew Star Plasma Brochure
New Star Plasma Brochure
Paul Mutch
 
Ingersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTbIngersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTb
Shaun Sullivan
 

Similar a Siemens Steam Turbines 45kW-12MW (20)

Industrial_Steam_Turbines_en.pdf
Industrial_Steam_Turbines_en.pdfIndustrial_Steam_Turbines_en.pdf
Industrial_Steam_Turbines_en.pdf
 
Industrial Steam Turbines Portfolio_EN
Industrial Steam Turbines Portfolio_ENIndustrial Steam Turbines Portfolio_EN
Industrial Steam Turbines Portfolio_EN
 
Industrial steam turbines_en
Industrial steam turbines_enIndustrial steam turbines_en
Industrial steam turbines_en
 
Pre-Designed_Turbocompressors
Pre-Designed_TurbocompressorsPre-Designed_Turbocompressors
Pre-Designed_Turbocompressors
 
Brochure gas turbine sgt 300 for power generation
Brochure gas turbine sgt 300 for power generationBrochure gas turbine sgt 300 for power generation
Brochure gas turbine sgt 300 for power generation
 
Catalogue n° HD-E-00
Catalogue n° HD-E-00Catalogue n° HD-E-00
Catalogue n° HD-E-00
 
Compact Muffle Furnace (1500 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1500 °C) by ACMAS Technologies Pvt Ltd.Compact Muffle Furnace (1500 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1500 °C) by ACMAS Technologies Pvt Ltd.
 
ceair presentation 2
ceair presentation 2ceair presentation 2
ceair presentation 2
 
Siemens Steam Turbine SST-600
Siemens Steam Turbine SST-600Siemens Steam Turbine SST-600
Siemens Steam Turbine SST-600
 
Heat exchangers
Heat exchangersHeat exchangers
Heat exchangers
 
Natural Gas Dryer for Fueling Station Operations
Natural Gas Dryer for Fueling Station OperationsNatural Gas Dryer for Fueling Station Operations
Natural Gas Dryer for Fueling Station Operations
 
ICS Brochure
ICS BrochureICS Brochure
ICS Brochure
 
Cpg 2010
Cpg 2010Cpg 2010
Cpg 2010
 
New Star Plasma Brochure
New Star Plasma BrochureNew Star Plasma Brochure
New Star Plasma Brochure
 
Compact Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.Compact Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
Compact Muffle Furnace (1800 °C) by ACMAS Technologies Pvt Ltd.
 
Wareender Sealless Magnetic Drive Pumps Overview
Wareender Sealless Magnetic Drive Pumps OverviewWareender Sealless Magnetic Drive Pumps Overview
Wareender Sealless Magnetic Drive Pumps Overview
 
Ingersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTbIngersoll Rand MT250 Microturbine Product Spec 080LTb
Ingersoll Rand MT250 Microturbine Product Spec 080LTb
 
Air source heat pump Brochure-BLUEWAY
Air source heat pump Brochure-BLUEWAYAir source heat pump Brochure-BLUEWAY
Air source heat pump Brochure-BLUEWAY
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 
Eta draco series reflow oven
Eta draco series reflow ovenEta draco series reflow oven
Eta draco series reflow oven
 

Siemens Steam Turbines 45kW-12MW

  • 1. siemens.com/energy/steamturbines Pre-designed Steam Turbines The comprehensive product range up to 12 megawatts Industrial Power Scan the QR code with the QR code reader in your mobile!
  • 2. A Full Range of World-class Industrial Steam Turbines Whatever your need for a prime mover, Siemens can provide you with versatile, reliable and proven indus- trial steam turbines. The world leader in steam turbine technology, with over 100 years of experience and continuous development, and a fleet of more than 20,000 installed turbines, we are a prime partner for your business. Siemens offers a comprehensive range of pre-designed steam turbines up to 12 MW. These innovative but eco- nomical machines have a simple modular design which facilitates optimization of performance for the required application. For optimal configuration, we have different but fully compatible design series to draw upon, enabling us to match your needs as exactly as possible. For our range of industrial steam turbines with a power output from 2 MW up to 250 MW and for large steam tur- bines from 250 MW to 1,200 MW, we offer separate port- folio brochures. Our predesigned steam turbines meet customer require- ments for economic installation and operation as well as providing excellent flexibility for complex industrial pro- cesses. So, whether you need a generator drive for power generation or a mechanical drive for compressors, blowers and pumps, just talk to us and together we can select the turbine or turboset which is optimally suited to your needs. Of course we strictly adhere to the guidelines laid down in the quality standards ISO 9001 and ISO 14001. Not only the steam turbines, but also associated field-proven high- tech products are available from the Siemens range. These include generators, instrumentation and controls, as well as auxiliary and ancillary systems. Type 1 2 3 4 5 6 7 8 9 10 11 12 Output (MW)Steam parameters (up to) SST-010 70 bar, 5 °C (Gas) SST-040 40 bar, 400 °C SST-050 101 bar, 500 °C SST-060 131 bar, 530 °C SST-110 131 bar, 530 °C SST-111 131 bar, 530 °C
  • 3. Pre-designed steam turbines The comprehensive Siemens product range up to 12 megawatts SST-040 (formerly known as AFA 3.5) up to 300 kW The SST-040 is a single-stage impulse turbine. The favorably priced turbine was designed as a generator drive for the 75-300 kW power range and can be used in small combined heat and power (CHP) plants, in decentralized solar facilities as well as for waste-heat re- covery, e.g. used behind gas engines and biogas engines or for the utilization of residual process steam. Technical data n Power output up to 300 kW n Inlet pressure up to 40 bar(a)/580 psi n Inlet temperature dry saturated steam up to 400 °C/750 °F n Speed acc. to driven machine n Exhaust pressure: from 0.1 bar (a)/1.5 psi condensation backpressure Typical dimensions Length 2.5 m/8.2 ft* Width 1.5 m/4.9 ft* Height 2 m/6.5 ft* Features n Backpressure or condensing type n Package unit design, oil unit integrated in base frame n Extremely small and compact design, total weight only 4,500 kg* n Only minimal foundation work required n Largely maintenance-free due to stalwart, robust construction n High availability thanks to resilient and sure technology n Quick start without preheating of the turbine n Favorably priced thanks to proven components n Quick installation and commissioning *complete turbine-generator set SST-010 (formerly known as EPM = Expansion Power Module) up to 110 kW The SST-010 is a compact turbogenerator designed to expand natu- ral gas in pressure regulating stations as a direct driving turbine in pipe installation. Technical data n Power output up to 110 kW n Gas pressure up to 70 bar(a)/1,015 psi n Gas flow rates up to 15,000 m3 /h/530,000 ft3 /h n Exhaust gas pressure up to 25 bar(a)/363 psi n Turbine wheel diameter 400 mm/15.75 in Typical dimensions Length 1.2 m/4 ft Width 0.8 m/2.6 ft Height 0.9 m/3 ft Features n Low-maintenance because of the simple design n Extremely failure safe n Quick-start compatible n Casing flanged directly into the gas pipeline n ATEX approved
  • 4. SST-060 (formerly known as AFA, CFA or CFR series) up to 6 MW The SST-060 stand out by their rugged design and renowned reli- ability even under the most severe operating conditions. They are ideal for saturated steam service. Their suitability for use as conden- sation or back-pressure turbines in combination with various inte- gral gears modules opens up a broad application range. Technical data n Power output up to 6 MW n Inlet pressure up to 131 bar(a)/1,900 psi n Inlet temperature dry saturated steam up to 530 °C/985 °F n Speed acc. to driven machine n Exhaust pressure: back pressure up to 29 bar(a)/420 psi or vacuum Typical dimensions Length 1.5 m/4.9 ft* Width 2.5 m/8.2 ft* Height 2.5 m/8.2 ft* Features n Backpressure or condensing type n Package unit design n Oil unit integrated in base frame n Nozzle group control valves available n Quick-start without pre-heating n Tailor made n Meet requirements of API 611/612** n ATEX version available n Suitable for ORC (Organic Rankine Cycle) n Suitable for gas expansion *turbine only **if overhung design and integral gear is accepted SST-050 (formerly known as AF or BF series) up to 750 kW The SST-050 is a single-stage, backpressure steam turbine in which the flow passes axially through the blading. It is mainly used as a power source for pumps or fans and especially as a stand-by unit with quick-start capability. Technical data n Power output up to 750 kW n Inlet pressure up to 101 bar(a)/1,465 psi n Inlet temperature dry saturated steam up to 500 °C/930 °F n Speed acc. to driven machine n Exhaust pressure: back pressure up to 11 bar(a)/160 psi Typical dimensions Length 1 m/3.3 ft* Width 1 m/3.3 ft* Height 1.3 m/4.3 ft* Features n Low-maintenance because of the simple design n Extremely failure safe n Quick-start compatible n Turbine with integral oil supply n Meet requirements of API 611/612** n ATEX version available *turbine only **if overhung design and integral gear is accepted
  • 5. SST-111 up to 12 MW The SST-111 is a dual or triple casing steam turbine with an integrated gearbox, designed for flexible operation and high efficiency. The multi-casing design allows for up to two controlled extractions as well as for operation on different steam supply systems. Technical data n Power output up to 12 MW n Inlet pressure up to 131 bar(a)/1,900 psi n Inlet temperature up to 530 °C/985 °F n Exhaust pressure: up to 0.06 bar (a)/8.7 psi condensation Typical dimensions Length approx. 8 m/26.2 ft (incl. generator) Width 4 m/13.1 ft Height 4 m/13.1 ft Features n Condensing type n Package unit design n Oil unit integrated in base frame n Nozzle group control valves available n Quick-start without pre-heating n Extremely compact construction n Pressure controlled extraction n High pressure/low pressure applications n ATEX version available n Reheat possible SST-110 (formerly known as TWIN version) up to 7 MW The SST-110 provides highest cost efficiency and high performance. It allows to reduce high heat gradients while providing a controlled extraction capability. The SST-110 is a dual casing turbine on one gearbox which can run on different steam lines. Technical data n Power output up to 7 MW n Inlet pressure up to 131 bar(a)/1,900 psi n Inlet temperature dry saturated steam up to 530 °C/985 °F n Speed acc. to driven machine n Exhaust pressure: back pressure or vacuum Typical dimensions Length approx. 6 m/20 ft (incl. generator) Width 2.8 m/9.2 ft Height 3.2 m/10.5 ft Features n Backpressure, extraction or condensing type n Package unit design n Oil unit integrated in base frame n Nozzle group control valves available n Quick-start without pre-heating n Extremely compact construction n Pressure controlled extraction n High pressure/low pressure applications n Meet requirements of API 611/612* n ATEX version available n Suitable for ORC (Organic Rankine Cycle) n Suitable for gas expansion *if overhung design and integral gear is accepted
  • 6.
  • 7. Fields of application Siemens industrial steam turbines ­increase the efficiency of power ­generation and improve the profit­ability of industrial applications. Industries n Chemistry n Food Beverage n Independent power producers n Manufacturing industries, producers of pumps and compressors n Petrochemistry/Refineries n Smelters/Steel n Sugar/Palmoil n Utilities n Wood-working industry/Paper mills Applications n Biomass power plants n Captive power plants n Cogeneration/CHP n Gas expansion n Geothermal plants n Heat-recovery n Mechanical drives n Ships/Offshore n Solar thermal plants n Waste incineration plants Main advantages n High efficiency n High reliability/availability n Customized proven solutions n Compact design n Simple installation and maintenance
  • 8. Published by and copyright © 2013: Siemens AG Energy Sector Freyeslebenstrasse 1 91058 Erlangen, Germany Siemens AG Energy Sector Oil Gas Division Wolfgang-Reuter-Platz 47053 Duisburg, Germany Siemens Energy Inc. 10730 Telge Road Houston, Texas 77095, USA For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) e-mail: support.energy@siemens.com Oil Gas Division Order No. E50001-W4100-A100-V2-4A00 Printed in Germany Dispo 34806, c4bs 7479 bdk 120175, P WS 0213.6 Printed on elementary chlorine-free bleached paper. All rights reserved. Trademarks mentioned in this document are the property of Siemens AG, its affiliates, or their respective owners. Subject to change without prior notice. The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The required technical options should therefore be specified in the contract.