Este documento proporciona información sobre iluminación para baños, incluyendo diferentes tipos de luminarias y sus especificaciones técnicas. También explica las zonas de iluminación en un baño y los requisitos de protección IP para cada zona según el riesgo de choque eléctrico.
2. G9
GU10
+
SYMBOLS
SÍMBOLOS
Cutting size for squares and rectangulars
Tamaño del corte cuadrado o rectangular
Cutting size for round
Tamaño del corte redondo
Swivelling
Orientable
Beam angle
Ángulo de apertura
Double light output
Doble salida de luz
The installation inside the shower its allowed
Permite la instalación dentro de la ducha
Motion sensor
Sensor de movimiento
Twilight sensor
Sensor crepuscular
Adaptor for mirrors
Adaptador para espejos
Adapters for mirrors and walls included
Adaptadores para espejos y paredes incluídos
G9 bulb included
Bombilla tipo G9 incluída
GU10 bulb included
Bombilla tipo GU10 incluída
3. l í n e a d e b a ñ o
EMPOTRABLES
APLIQUES
PAG 15 PAG 15 PAG 17
PAG 17 PAG 21 PAG 21 PAG 23 PAG 23
PAG 11 PAG 13 PAG 13 PAG 13PAG 11
PAG 19 PAG 19
SUPERFICIE
PAG 25 PAG 25 PAG 27 PAG 27 PAG 29 PAG 29 PAG 31 PAG 31
PAG 5 PAG 5 PAG 7 PAG 7 PAG 9 PAG 9 PAG 33
4.
5. b a t h r o o m l i g h t i n g
05
COB FIX PLUS IP 44
EMPOTRABLE SQUARE 100888
9W 3000K 710LM ALU white
93X93mm
75mm
COB FIX PLUS IP 44
EMPOTRABLE ROUND 100887
9W 3000K 710LM ALU white
93mm
75mm
80mm
IP44
IP44
36º
LED
36º
LED
80mm
6.
7. b a t h r o o m l i g h t i n g
COB FIX IP 54
EMPOTRABLE SQUARE 100998
10W 4000K 700LM ALU white
100X100mm
27mm
90x90mm
COB FIX IP 54
EMPOTRABLE ROUND 100999
10W 4000K 700LM ALU white
100mm
27mm
86mm
07
IP54
IP54 30º
38º
LED
30º
38º
LED
8.
9. b a t h r o o m l i g h t i n g
09
DOWNLIGHT epistar IP 65
EMPOTRABLE SQUARE 112052
7W 4000K 560LM ALU white
90X90mm
45mm
DOWNLIGHT epistar IP 65
EMPOTRABLE ROUND 112050
7W 4000K 560LM ALU white
90mm
45mm
75mm
IP65
IP65
110º
LED
LED
110º
75mm
10.
11. b a t h r o o m l i g h t i n g
11
CONFORT IP 44
1L 541100
5W 4000K 350LM CR
110mm
100mm
IP44
60º
GU10LED
CONFORT IP 44
3L 541330
5 x 3W 4000K 350 x 3LM CR
110mm
250mm
IP44
60º
GU10LED
12.
13. b a t h r o o m l i g h t i n g
13
IP44
CONFORT IP 44
2L 541200
5 x 2W 4000K 350 x 2LM CR
70mm
400mm
IP44
CONFORT IP 44
3L 541300
5 x 3W 4000K 350 x 3LM CR
60º
GU10LED
60º
GU10LED
IP44
CONFORT IP 44
3L 541440
5 x 4W 4000K 350 x 4LM CR
110mm
850mm
60º
GU10LED
110mm
110mm
70mm
600mm
110mm
14.
15. 15
CILINDRO IP 44
APLIQUE 393326
2G9 x 40W 3000K CR GL
60mm
CILINDRO IP 44
APLIQUE 393520
2G9 x 40W 3000K CR GL
IP44
IP44
260mm 40mm
260mm
80mm
80mm
2xG9
2xG9
b a t h r o o m l i g h t i n g
16.
17. 01
b a t h r o o m l i g h t i n g
17
CILINDRO IP 44
APLIQUE 393324
2G9 x 40W 3000K MET GL
60mm
CILINDRO IP 44
APLIQUE 393320
2G9 x 40W 3000K MET GL
IP44
IP44
260mm
80mm
2xG9
2xG9
60mm
260mm
80mm
18.
19. b a t h r o o m l i g h t i n g
19
APLIQUE IP 44
FIJO 541310
1G9 x 40W 3000K CR GL
IP44 2xG9
APLIQUE IP 44
REGULABLE 541320
2G9 x 40W 3000K CR GL
IP44 2xG9
40mm
260mm
80mm
220mm
100mm
60mm
20.
21. b a t h r o o m l i g h t i n g
21
H2O IP 44
ILUMINAESPEJOS 142000
7W 4000K 560LM CR
40mm
H2O IP 44
ILUMINAESPEJOS 142001
10W 4000K 800LM CR
IP44
IP44
300mm
50mm
400mm
110mm
102mm
LED
LED +
+
22.
23. b a t h r o o m l i g h t i n g
23
COB CHERRY IP 55
WALL LAMP 111046
LED 4,5W 3000K 200LM ALU white
75mm
COB CHERRY IP 55
WALL LAMP 111047
LED 4,5W x 2 3000K 200LM x 2 ALU white
45x45mm
110mm
45x45mm
IP55
25º
LED
IP55
25º
LED
24.
25. b a t h r o o m l i g h t i n g
25
PLAFÓN NATURE IP 44
SUPERFICIE ROUND 111113
12W 4000K 800LM ACR
45mm
PLAFÓN NATURE IP 44
SUPERFICIE ROUND 111119
18W 4000K 1200LM ACR
IP44
IP44
200mm
45mm
270mm
120º
LED
120º
LED
26.
27. PLAFÓN NATURE IP 44
SUPERFICIE SQUARE 111121
12W 4000K 800LM ACR
45mm
PLAFÓN NATURE IP 44
SUPERFICIE SQUARE 111117
18W 4000K 1200LM ACR
IP44
IP44
200x200mm
45mm
270x270mm
120º
LED
120º
LED
27
l í n e a d e b a ñ o
28.
29. b a t h r o o m l i g h t i n g
29
PLAFÓN NATURE
SUPERFICIE ROUND 111120
8W 4000K 800LM ACR
45mm
PLAFÓN NATURE
SUPERFICIE ROUND 111122
18W 4000K 1200LM ACR
IP44
IP44
200mm
45mm
280mm
120º
LED
120º
LED
30.
31. b a t h r o o m l i g h t i n g
31
PLAFÓN SENSOR IP 23
ROUND 101325
18W 4000K 1440LM ACR
80mm
320mm
IP23
120º
LED
PLAFÓN IP 44
SQUARE 111362
15W 4000K 1050LM ACR
18mm
295x295mm
IP44
120º
LED
32.
33. 33
RAYFIX WIDE IP 44
WALL WASHER 111042
3W 3000K 100LM ALU white
130mm
45x45mm
IP44 LED
40x120mm
b a t h r o o m l i g h t i n g
34. Zone 0. The interior of the bath or shower that can hold water.
Requires electrical products to be low voltage (max 12V) and
rated IPX7.
Zone 1. The area directly above zone 0 limited to a heigh of
2,25m above the bath or shower. Requires electrical products to
have an IPX4 or better. Products using safeti extra low voltage
(SELV) can be used but the transformer must be located in zone
3 or beyond.
First digit/Protection from solid objects
0 No protection
1 Protection against solid objets with diameter greater than 50mm
2 Protection against solid objets with diameter greater than 12mm
3 Protection against solid objets with diameter greater than 2,5mm
4 Protection against solid objets with diameter greater than 1mm
5 Dust protected
6 Dust tight
Second digit/Protection from moisture
0 No protection
1 Protection from dripping water
2 Protection from dripping water when tilted upto 15 degrees
3 Protection from spraying water (rain)
4 Protection fromsplashing water
5 Protection from water jets
6 Protection from heavy seas
7 Protection from sumersion in water
8 Protection from continuous submersion in water
tDETAILS ON WHAT THE DIFFERENT IP NUMBERS MEAN
A SAFE LIGHTING IN THE BATHROOM
For the purposes of installing electrical equipment, a bathroom is divided into zones. The criteria for ecah zone is
based on the risk of electrick shock. The zones relate to the IP rating of products and where they can be safety
installed.
LIGHTING ZONES
ZONE
1
ZONE
2
ZONE
2
ZONE
2
60cm
60cm 60cm
225cm
ZONE
0
Zone 2. The area beyond zones 0 a 1, stretching 0,6m
horizontally and up to 2,25m vertically, Also includes the
recessed area of a window with a sill next to the bath. Requires
electrical products to have an IPX4 or better. SELV with the
transformer located in zone 3 or beyond.
Zone 3. The area beyond zone 2, stretching 2,4 horizontally
and up to 2,25m vertically, used to be rated as zone 3 but this
is now not separated and anylighting fitting can go in this area.
There is not a specified IP number for this area, although some
products are marked as not for bathroom use. SELV or shaver
units are permitted, all other portable electrical equipment is not.
35. 35
Zona 0. El interior del lavabo, la ducha o bañera son zonas que
van a contener agua, por lo que requieren productos elécticos
específicos para una sumersión continuada, de bajo voltaje
(máx. 12V), y con un IPX7.
Zona 1. Es el área que está directamente sobre las zonas cero,
con un límite de altura de 2,25m por encima del lavabo, ducha
o bañera. Requerirán productos con un IPX4 o superior.
Se pueden usar aparatos con bajo voltaje de seguridad, pero el
transformador deberá estar localizado a partir de la zona 3.
Primer dígito/Protección de objetos sólidos
0 Sin protección
1 Protegido de objetos sólidos con diámetro mayor que 50mm
2 Protegido de objetos sólidos con diámetro mayor que 12mm
3 Protegido de objetos sólidos con diámetro mayor que 2,5mm
4 Protegido de objetos sólidos con diámetro mayor que 1mm
5 Protegidos del polvo
6 A prueba de polvo
Segundo dígito/Protección de humedad
0 Sin protección
1 Protegido del goteo del agua
2 Protegido del goteo del agua inclinado más de 15º
3 Protegido del agua en spray
4 Protegido de salpicaduras de agua
5 Protegido de chorros de agua
6 Resistente al agua
7 Sumergible
8 Protegido de una sumersión continua
TABLA DE RELACIÓN DEL ÍNDICE IP
SIGNIFICADO DEL LOS NÚMEROS IP
UNA ILUMINACIÓN SEGURA EN EL BAÑO
Con el propósito de una correcta instalación de los materiales eléctricos para una ótima iluminación, un baño
está dividido en zonas. En función del nivel de IP, la zona donde puede ser instalado de forma segura, varía.
ZONAS DE ILUMINACIÓN
ZONA
1
ZONA
2
ZONA
2
ZONA
2
60cm
60cm 60cm
225cm
ZONA
0
Zona 2. Es el área que continúa a la 1, se extiende 0,6m a
lo ancho y 2,25m a lo alto. Necesitará productos con IPX4
o superiores. Se pueden usar aparatos con bajo voltaje de
seguridad si el driver está instalado a partir de la zona 3.
Zona 3. Es el área contigua a la zona 2, y desde ésta se
extiende 2,24m a lo ancho y 2.25 a lo alto. En esta zona se
puede instalar cualquier equipo eléctrico, no se requiere ningún IP
específico, sin embargo algunos productos no se recomiendan
para instalar en el baño si no cuentan con ninguna protección IP.
36. C/ Verano 51 // Polígono Industrial Las Monjas
28850 Torrejón de Ardoz // Madrid // España
www.sul.es info@sul.es 916 774 540 F 916 775 450
LÁMPARAS SCHULLER S.A.
Prohibida la reproducción total o parcial de este catálogo, así como la trasmisión y difusión
en cualquier soporte o medio, mecánico o electrónico, sin el permiso por escrito de Lámparas
Schuller S.A. Lámparas Schuller S.A. se reserva el derecho a modificar características o
medidas de sus productos sin previo aviso.