Claves para la correcta
ejecución de un sistema SATE
Ponente: Pablo Antonio Díaz Jiménez – ICCP|Prescriptor Córdoba y Jaén
Moderadora: Laura Jiménez – Arquitecto Técnico|Prescriptora zona centro
Julio 2020
························
························
························
························
························
························
Claves para la correcta ejecución de un
sistema SATE
Impartida por: Pablo A. Díaz Jiménez – ICCP | Técnico Prescriptor
Julio 2020
························
• Introducción y ventajas
• Componentes del sistema
• Patologías más comunes
• Claves para la correcta ejecución del sistema
• Detalles constructivos
• Servicios Grupo Puma
• Preguntas
Índice de contenidos
························
¿POR QUÉ ES NECESARIO MEJORAR EL
AISLAMIENTO TÉRMICO EN LOS EDIFICIOS?
SITUACIÓN ACTUAL
························
En Europa, > 40% de la energía que se consume, procede de la CALEFACCIÓN Y
REFRIGERACIÓN de los edificios
D1
SITUACIÓN ACTUAL
························
Esta energía es de origen FÓSIL y por tanto su consumo genera CO2  CONTAMINACIÓN.
D2
SITUACIÓN ACTUAL
························
Las políticas y normativas que están surgiendo están enfocadas al ahorro de energía y
disminución de consumo energético:
DIRECTIVA EUROPEA 2010/31/UE > Edificios de consumo casi nulo (ECCN/nZEB)
POR ESTA RAZÓN OBSERVAMOS QUE …
D3
REGLAMENTACIÓN
························
¿POR QUÉ UN SISTEMA DE AISLAMIENTO PARA FACHADA?
Distribución de Pérdidas de Energía en un Edificio (datos IDAE)
D7
PÉRDIDAS DE ENERGÍA
························
SISTEMAS TRADITERM®
EXISTE LA NECESIDAD de desarrollar soluciones constructivas, que
reduzcan el consumo energético, no sólo para ser aplicadas en el diseño de
nuevos edificios, si no también en los edificios existentes. Un ejemplo de estas
soluciones constructivas son los …
CON TODO ESTO….
D5
SOLUCIÓN PARA LA MEJORA ENERGÉTICA
························
• Mejora la eficiencia energética del edificio, lo que implica un ahorro
económico en el gasto de calefacción o refrigeración de un edificio.
• INVERSIÓN AMORTIZABLE
D8
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
La instalación del Sistema Traditerm®
• No afecta al uso del edificio. Interés en Rehabilitación Energética de
edificios existentes.
• No se pierden superficie interior de la vivienda, puesto que va colocado
por el exterior
D9
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
• Aumento de la protección de la fachada
– Impermeabilización
– Disminución de las tensiones: fisuras, expansión
térmica, por cambios de temperatura, etc.
D10
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
• Eliminación de los puentes térmicos a nivel de forjados
(de interés en obra nueva también)
EDIFICIO SIN AISLAR AISLAMIENTO INTERIOR AISLAMIENTO EXTERIOR
D11
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
• Minimiza el riesgo de formación de condensaciones interiores y posterior
formación del moho interior ya que los sistemas son permeables al vapor
de agua y dejan respirar al edificio
D12
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
• El Sistema Traditerm® rejuvenece la fachada y revaloriza el edificio
D13
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
Los Sistemas Traditerm® se encuentra homologado a nivel europeo. ETE Nº
07/0054
D16
VENTAJAS DE LOS SISTEMAS SATE TRADITERM ®
························
Sistema TRADITERM®
Traditerm EPS Traditerm EPS-G Traditerm Mineral Traditerm Nature
D23
TIPOS DE SISTEMA TRADITERM ®
························
D23
Traditerm Traditerm EPS Flexible Traditerm EPS-G Flexible
Traditerm Ceramic Traditerm Estuco Fino Traditerm Monocapa
Acabado mortero acrílico Morcemcril / Morcemcril siloxano / Morcemcril flexible
Otros acabados
························
Componentes
Sistemas Traditerm®
D17
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
SOPORTES DE OBRA NUEVA
D18.1.1
························
D18.1.2
SOPORTES REHABILITACIÓN
························
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
ARRANQUE DEL SISTEMA TRADITERM
Perfil de aluminio especialmente diseñado para el arranque y la protección
de la parte inferior de los Sistemas Traditerm®.
• No se oxida.
• Posee goterón incorporado.
• Gama de espesores, según el espesor de panel aislante utilizado.
• Formato: 2,5 m/unidad.
Traditerm Perfil arranque
aluminio
D18.2.1
························
D18.2.2
ARRANQUE DEL SISTEMA TRADITERM
Accesorios Perfil de Arranque
························
TRADITERM KIT INSTALACIÓN PERFIL DE ARRANQUE
Kit completo para el montaje del perfil de arranque en los Sistemas Traditerm.
El Kit se compone de:
• Tornillos 6x60 mm
• Conectores de perfil de arranque.
• Separadores de perfil de arranque en 3 mm
TRADITERM SEPARADOR DE PERFIL
Elemento de corrección de ligeras irregularidades en el soporte, para el
montaje del perfil de arranque en los Sistemas Traditerm.
• Gama de Tamaños: 3, 5, 8, 10, 15 mm
TRADITERM SEPARADOR DE PERFIL
Conector para perfiles y raíles para la instalación del sistema Traditerm.
•Sencilla fijación a presión en los carriles
• Disponible en 30 mm y 150 mm
D18.2.3
ARRANQUE DEL SISTEMA TRADITERM
Accesorios Perfil de Arranque
························
D18.2.4
ARRANQUE DEL SISTEMA TRADITERM EPS SIN AISLAR
························
D18.2.5
ARRANQUE DEL SISTEMA TRADITERM
························
D18.2.6
ARRANQUE DEL SISTEMA TRADITERM EPS ENTERRADO
························
D18.2.7
ARRANQUE DEL SISTEMA TRADITERM EPS A NIVEL DE SUELO
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
Método de llana dentada
D18.3.4
PEGADO DE PANEL AISLANTE
························
D18.3.5
PEGADO DE PANEL AISLANTE
Método del cordón de mortero
························
ELECCIÓN DEL MÉTODO DE PEGADO DE PANEL AISLANTE
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
Placa de Poliestireno Expandido utilizada como panel aislante en el
Sistema Traditerm EPS.
• Formato: 1000 x 500 mm
• Espesor: 20,30, 40, 50, 60, 70, 80, 100, 120, 140, 150, 160, 180, 200 mm
• Estabilizado.
• Conductividad Térmica (λ): 0,036 – 0,038 W/mK
• Reacción al fuego: E Autoextinguible (UNE-EN 13501-1)
Traditerm Panel EPS
PANEL AISLANTE
D18.4.1
························
D18.4.2
PANEL AISLANTE
························
RECOMENDACIONES
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
Traditerm® Taco de Anclaje H1 Eco
Taco de anclaje de percusión para la fijación de paneles aislantes en el
sistema de aislamiento térmico exterior TRADITERM. Anclaje de alta
calidad y seguridad.
Traditerm® Taco de Anclaje STR U 2G
Taco de anclaje con clavo roscado, para la fijación de paneles aislantes
en el sistema de aislamiento térmico exterior TRADITERM®. Anclaje de
alta calidad y seguridad.
Traditerm® Taco de Anclaje STR H
Taco de anclaje para soportes de madera con tornillo zincado.
D18.5.2
TIPOLOGÍA DE TACOS DE ANCLAJE
Traditerm® Taco de Anclaje
Taco de anclaje para fijación de paneles aislantes en los Sistemas
Traditerm
························
D18.5.3
MÉTODO SUPERFICIAL
························
Traditerm® Tapa Aislante EPS | EPS-G | Lana Mineral
Tapa aislante (EPS, EPS-G o Lana mineral)
para rellenar el hueco que la corona STR
deja en el panel aislante, cuando se instala
el Traditerm Taco de Anclaje STR U 2G.
D18.5.4
MÉTODO INTERIOR
························
D18.5.5
DISTRIBUCIÓN TACOS DE ANCLAJE 6 TACOS/m2
························
D18.5.6
DISTRIBUCIÓN TACOS DE ANCLAJE 8 TACOS/m2
························
D18.5.7
MÉTODO SUPERFICIAL MAL EJECUTADO
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
Traditerm lijadora metálica
Llana especialmente diseñada para el lijado de grandes espesores de los paneles
aislantes tipo Traditerm Panel EPS y tipo Traditerm Panel EPS-G
Traditerm lijadora EPS
Llana para el lijado de las juntas de paneles aislantes tipo Traditerm Panel EPS
y tipo Traditerm Panel EPS-G
D18.6.1
LIJADO DE PANELES
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
La finalidad de este revestimiento, es dotar de resistencias
mecánicas al panel aislante.
RESISTENCIA MECÁNICA
SUPERFICIE PANEL AISLANTE
CAPA DE MORTERO TRADITERM
(20-30 mm de espesor)
CAPA RÍGIDA = FISURAS
NO FISURAS = CAPA FLEXIBLE
CAPA DE MORTERO TRADITERM
(3-5 mm de espesor)
CAPA FLEXIBLE = MUY BAJA
RESISTENCIA MECANICA
RESISTENCIA
FLEXIBILIDAD
D18.7.1
REVESTIMIENTO DE PANEL
························
¿Cómo conseguir este equilibrio?
Capa de mortero Traditerm de 3-5 mm de espesor,
armado con la Malla Traditerm.
RESISTENCIA
FLEXIBILIDA
D
D18.7.2
REVESTIMIENTO DE PANEL
························
COLOCACIÓN MORTERO – MALLA - MORTERO
························
 TRADITERM MALLA
• Tratamiento anti-alcalino
• Gramaje 160 g/m2
• Luz de la malla 4x5 mm
• Presentación en rollos de 1x50 m
 TRADITERM MALLA DE REFUERZO
• Tratamiento anti-alcalino
• Gramaje 330 g/m2
• Luz de la malla 6x6 mm
• Presentación en rollos de 1x25 m
D18.8.2
TRADITERM MALLA
························
¿CUANDO ES NECESARIO REFORZAR EL
SISTEMA CON UNA SEGUNDA MALLA?
• Zonas susceptible de actos vandálicos
• Patios de colegios, parkings, edificios públicos
Mortero / Malla 330g (sin solapes) / Secado
+
Mortero / Malla 160g (con solapes) / Mortero
Aplicación:
D18.8.3
TRADITERM MALLA
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
¿QUÉ ES EL FONDO ACRÍLICO Y SU IMPORTANCIA?
D18.9.1
························
Imprimación de resinas sintéticas, previa a los acabados decorativos de la
Gama Morcemcril, proporcionándole:
• Una base o soporte con una absorción homogénea.
• Favorece su cubrición.
• Facilita su adherencia.
• Aumenta su durabilidad del acabado Morcemcril.
D18.9.2
MORCEMCRIL FONDO
························
DESPRENDIMIENTO ACABADO ACRÍLICO POR AUSENCIA DE IMPRIMACIÓN
D18.9.5
MORCEMCRIL FONDO
························
01: SOPORTE
02: TRADITERM PERFIL DE ARRANQUE
03: MORTERO TRADITERM
04: TRADITERM PANEL AISLANTE
Método del cordón Método llana dentada
05: TRADITERM TACO DE ANCLAJE
06: LIJADO DE PANELES
07: CUBRICIÓN TACOS DE ANCLAJE
08: MORTERO TRADITERM
09: TRADITERM MALLA
10: MORTERO TRADITERM
11: FONDO MORCEMCRIL
12: MORCEMCRIL
COMPONENTES DE LOS SISTEMAS TRADITERM
D18
························
¿QUÉ ES UN MORTERO ACRÍLICO?
D18.10.1
ACABADO ACRÍLICO
························
COMPOSICIÓN GENERAL DE UN MONOCAPA
CEMENTO / CAL
ÁRIDOS – CARGAS DE INERTES
HIDROFUGANTES
PIGMENTOS
COMPOSICIÓN GENERAL DE UN MORTERO ACRÍLICO
CEMENTO / CAL
ÁRIDOS – CARGAS DE INERTES
HIDROFUGANTES
PIGMENTOS
SE CAMBIA POR RESINA ACRÍLICA
D18.10.3
ACABADO ACRÍLICO
························
PROPIEDADES
MONOCAPA MORTERO ACRÍLICO
ADHERENCIA
IMPERMEABILIDAD
DEFORMABILIDAD
ESTABILIDAD DEL COLOR
DURABILIDAD
NO NECESARIO REVESTIMIENTO BASE
D18.10.4
ACABADO ACRÍLICO
························
D18.10.9
COMPARATIVA DE PRODUCTOS
························
Complementos
Sistemas Traditerm ®
D20
························
01: ARRANQUE DEL SISTEMA TRADITERM
02: TRADITERM MALLA VÉRTICE
06: TRADITERM PERFIL CORONACIÓN
04: TRADITERM PERFIL GOTERÓN PVC CON MALLA
03: TRADITERM PERFIL ÁNGULO PVC CON MALLA
05: SELLADO PUMALASTIC MS
07: TRADITERM PERFIL CIERRE LATERAL
COMPLEMENTOS SISTEMA TRADITERM
D21
························
Malla de fibra de vidrio con tratamiento anti-álcalis y por hilos de doble torsión,
que combinada con la Malla TRADITERM, se utiliza como refuerzo para
aumentar la resistencia en los vértices de huecos
TRADITERM MALLA VÉRTICE
························
REFUERZO DE VENTANA
························
Perfil de PVC peforado para el refuerzo de esquinas y huecos en los
Sistemas de Aislamiento Térmico Exterior TRADITERM (SATE/ETICS).
TRADITERM PERFIL ÁNGULO PVC CON MALLA
························
ENCUENTRO CON ESQUINA
························
Perfil de PVC provisto de malla con tratamiento antialcalino, Especialmente diseñado
para la formación de goterones en los Sistemas Traditerm.
• No se oxida.
• Formato: 2,5 m/unidad
TRADITERM PERFIL GOTERÓN PVC CON MALLA
························
ENCUENTRO CON VOLADIZO
························
Masilla con base química Polímero MS, diseñada para el sellado de los encuentros
de los Sistemas Traditerm con otros elementos de la fachada.
• Formato: 290 ml/bote.
SELLADO CON PUMALASTIC MS
························
Perfil de protección, que se coloca en la parte superior de los Sistemas Traditerm.
• Perfil de Aluminio
• Gama de espesores, según el espesor de panel aislante utilizado.
• Formato: 2,5 m/unidad.
CORONACIÓN DEL SISTEMA
························
Perfil de Aluminio utilizado como refuerzo y cierre de los extremos laterales
de los Sistemas Traditerm.
• No se oxida.
• Gama de espesores, según el espesor de panel aislante utilizado.
• Formato: 2,5 m/unidad.
PERFIL DE CIERRE LATERAL
························
FIJACIÓN DE ELEMENTOS A LA FACHADA
CARGAS PESADAS: TRADITERM 300 CARGAS LIGERAS HASTA 5KG:
TRADITERM ANCLAJE ESPIRAL
························
D34
PATOLOGÍAS MÁS COMÚNES SISTEMA SATE
DESPEGUE GENERAL DEL SISTEMA
DESPEGUE PARCIAL DEL SISTEMA
INFILTRACIONES DE AGUA A TRAVÉS DEL SISTEMA
MICROFISURACIÓN
ABOMBAMIENTO Y/O EMBOLSAMIENTO DEL
REVESTIMIENTO
MOHOS Y ALGAS
ANOMALÍAS ASOCIADAS AL ASPECTO DEL
REVESTIMIENTO
OTRAS ANOMALÍAS
DEGRADACIÓN DEL ADHESIVO O REVESTIMIENTO
FTE.: ISOLAMENTO TÉRMICO DE FACHADAS PELO EXTERIOR_MAXIT GROUP
························
D34
MICROFISURACIÓN
························
D34
PRINCIPALES CAUSAS_MICROFISURACIÓN
MALA FIJACIÓN DE LOS PANELES DE AISLAMIENTO AL SOPORTE
AUSENCIA DE JUNTAS ENTRE PERFILES
COINCIDENCIA DE JUNTAS DE PERFILES Y JUNTAS ENTRE PLACAS
COINCIDENCIA DE LAS JUNTAS ENTRE PLACAS Y
DISCONTINUIDADES DEL SOPORTE
SUPERFICIE IRREGULAR DE LA CAPA AISLANTE. FALTA DE LIJADO
CAPA DE MORTERO INSUFICIENTE PARA EMBEBER LA MALLA
MALA COLOCACIÓN DE LA MALLA Ó AUSENCIA DE ELLA
FALTA DE DESOLIDARIZACIÓN ENTRE EL SISTEMA Y OTROS
ELEMENTOS CONSTRUCTIVOS
UTILIZACIÓN DE REVESTIMIENTOS DEMASIADO OSCUROS
························
D34
PATOLOGÍA_MICROFISURACIÓN_MALA ADHERENCIA DEL PANEL AL SOPORTE
························
D34
PATOLOGÍA_MICROFISURACIÓN_MALA FIJACIÓN DEL PANEL AL SOPORTE
1
2
3
························
D34
PATOLOGÍA_MICROFISURACIÓN_CAPA DE MORTERO INSUFICIENTE PARA EMBEBER LA
MALLA
························
D34
PATOLOGÍA_MICROFISURACIÓN_CAPA DE MORTERO EXCESIVA PARA EMBEBER LA
MALLA
························
D34
PATOLOGÍA_MICROFISURACIÓN_MALA COLOCACIÓN DE LA MALLA Ó AUSENCIA DE ELLA
························
D34
PATOLOGÍA_MICROFISURACIÓN_MALA COLOCACIÓN DE LA MALLA Ó AUSENCIA DE ELLA
························
D34
PATOLOGÍA_MICROFISURACIÓN_FALTA DE DESOLIDARIZACIÓN ENTRE SISTEMA Y
OTROS ELEMENTOS CONSTRUCTIVOS
························
D34
PATOLOGÍA_MICROFISURACIÓN_UTILIZACIÓN DE REVESTIMIENTOS DEMASIADO
OSCUROS
························
D34
ABOMBAMIENTO Y/O EMBOLSAMIENTO DEL REVESTIMIENTO_
························
D34
PRINCIPALES CAUSAS_ABOMBAMIENTO O EMBOLSAMIENTO DE REVESTIMIENTO
APLICACIÓN DE MORTERO TRADITERM EN CONDICIONES
ATMOSFÉRICAS INADECUADAS
NO RESPETAR LOS TIEMPOS DE SECADO
APLICACIÓN DE MORTERO TRADITERM SOBRE PLACAS DE
POLIESTIRENO DEGRADADAS
RESTOS DE MORTERO TRADITERM ENTRE PLACAS DE
AISLANTE
························
D34
PATOLOGÍA_APLICACIÓN DE MORTERO TRADITERM EN CONDICIONES
ATMOSFÉRICAS INADECUADAS
························
D40
PATOLOGÍA_RESTOS DE MORTERO TRADITERM ENTRE PLACAS
························
D34
DESCUELGUE PARCIAL O TOTAL DEL SISTEMA_
························
D34
PRINCIPALES CAUSAS_DESCUELGUE PARCIAL O TOTAL DEL SISTEMA
FALTA DE TRATAMIENTO DEL SOPORTE
MALA REPARTICIÓN DEL PRODUCTO ADHESIVO O
FALTA DE COMPRESIÓN
DEFICIENTE TRATAMIENTO DE PUNTOS SINGULARES
MALA COLOCACIÓN DE PLACAS DE AISLANTE
························
D40
PATOLOGÍA_MALA REPARTICIÓN DEL PRODUCTO ADHESIVO O FALTA DE
COMPRESIÓN
························
D40
PATOLOGÍA_MALA REPARTICIÓN DEL PRODUCTO ADHESIVO O FALTA DE
COMPRESIÓN
························
D40
PATOLOGÍA_DEFICIENTE TRATAMIENTO DE PUNTOS SINGULARES
························
D34
CASO PRÁCTICO_CENTRO ESCOLAR
LOCALIZACIÓN_CELORICO DE BASTO_PORTUGAL
AÑO_2011
························
D34
CASO PRÁCTICO_CENTRO ESCOLAR_CELORICO DE BASTO (PORTUGAL)
························
D34
CASO PRÁCTICO_CENTRO ESCOLAR_CELORICO DE BASTO (PORTUGAL)
························
D34
EMBOLSAMIENTO DEL MORTERO DE REVESTIMIENTO
························
D34
JUNTAS ENTRE PANELES MARCADAS
························
D34
DETALLE DE EMBOLSAMIENTOS DEL REVESTIMIENTO
SILUETA DE JUNTA ENTRE PLACAS DIMENSIÓN DE LOS EMBOLSAMIENTOS ENTRE PLACAS
························
D34
MORTERO TRADITERM ENTRE PLACAS AISLANTES
························
D34
FALTA DE TACOS DE ANCLAJE
························
D34
FISURAS LONGITUDINALES_COLOR EXCESIVAMENTE OSCURO DE
REVESTIMIENTO
························
D34
FISURAS LONGITUDINALES_COLOR EXCESIVAMENTE OSCURO DE
REVESTIMIENTO
························
D34
DEFICIENTE COLOCACIÓN DE LA MALLA DE REVESTIMIENTO
························
D34
DEFICIENTE APLICACIÓN DE MORTERO ADHESIVO
························
D34
CASO PRÁCTICO_PRECAUCIONES
COLOCACIÓN DE PLACAS A HUESO
························
D34
CASO PRÁCTICO_PRECAUCIONES
CORRECTA DISTRIBUCIÓN DE TACOS DE ANCLAJE
6 TACOS/m2 8 TACOS/m2
························
D34
CASO PRÁCTICO_PRECAUCIONES
RESPETAR LOS ESPESORES DE TRADITERM + MALLA + TRADITERM
························
D34
CASO PRÁCTICO_PRECAUCIONES
CORRECTA APLICACIÓN DEL ADHESIVO Y PRESIÓN DE PANELES
························
D34
CASO PRÁCTICO_GRAN SUPERFICIE
LOCALIZACIÓN_ÚBEDA_JAÉN
AÑO_2018
························
D34
FISURAS LONGITUDINALES EN FACHADA
························
D34
FISURAS LONGITUDINALES EN FACHADA
························
D34
CATA REALIZADA EN FACHADA
························
D34
SEPARACIÓN ENTRE PLACAS DE AISLAMIENTO
························
D34
ESPESOR INSUFICIENTE DE MORTERO TRADITERM DE REVESTIMIENTO
························
D34
ESPESOR INSUFICIENTE DE MORTERO TRADITERM DE REVESTIMIENTO
························
D34
ESPESOR INSUFICIENTE DE MORTERO TRADITERM DE REVESTIMIENTO
························
D34
DEFICIENTE TRATAMIENTO DE PUNTOS SINGULARES
························
D34
CASO PRÁCTICO_PRECAUCIONES
CORRECTO TRATAMIENTO DE HUECOS
························
D34
CASO PRÁCTICO_PRECAUCIONES
CORRECTA COLOCACIÓN DE SOLAPES DE MALLA
························
D34
CASO PRÁCTICO_PRECAUCIONES
CORRECTA COLOCACIÓN DE MALLA SOBRE PLACAS AISLANTES
························
D34
CASO PRÁCTICO_PRECAUCIONES
RESOLUCIÓN DE ENCUENTROS CON VIERTEAGUAS
························
D34
CASO PRÁCTICO_PRECAUCIONES
SELLADO DE PUNTOS SINGULARES
························
Detalles constructivos
D30
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Diferentes soluciones para resolver el arranque del sistema
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Resolución vierteaguas de ventana en obra nueva
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Encuentro dintel con caja de persiana
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Coronación de peto de cubierta
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Sección horizontal. Hueco de ventana con jambas aisladas / sin aislar
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Resolución zona en voladizo / encuentro con balcón
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Encuentro con cubierta inclinada
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Refuerzo en esquinas de huecos
························
Sistema TRADITERM®DETALLES CONSTRUCTIVOS HABITUALES | SISTEMA TRADITERM ®
Refuerzo en esquina
························
························
························
D44
INFORMES TÉCNICOS PREDIMENSIONAMIENTO ESPESORES DE AISLAMIENTO EN SATE
························
D44
INFORMES TÉCNICOS: DATOS NECESARIOS PARA SU REALIZACIÓN
• Datos de contacto del solicitante
• Obra nueva / Rehabilitación energética
• Provincia
• Localidad
• Altitud de la parcela
• Composición hoja portante de fachada (obra nueva) o
composición de la fachada existente (rehabilitación).
························
D44
INFORMES TÉCNICOS: ENVÍOS EXPRESS
························
························
························
························
························
························
Pablo Antonio Díaz Jiménez
ICCP|Prescriptor Grupo Puma Córdoba y Jaén
Grupo Puma
Teléfono: 627 40 24 90
E-mail: pdiaz@grupopuma.com
························
························
ADVERTENCIA LEGAL
Reservados todos los derechos. Los contenidos de la presente documentación están
protegidos por Ley. No está permitida la explotación, reproducción total o parcial de
este documento ni su tratamiento informático, distribución o transmisión por
cualquier forma, medio o método sin el permiso previo y por escrito de GRUPO PUMA
S.L.
Este documento contiene información de carácter general, sin que constituya
prescripción ni asesoramiento profesional sobre los productos o soluciones
constructivas cuya información se contiene en el mismo, debiendo el destinatario en
caso de uso o aplicación de los mismos cerciorarse de su idoneidad atendiendo a sus
características y a las condiciones, soporte y posibles patologías de la obra en
cuestión, así como atenerse en todo caso a los requerimientos e instrucciones
contenidos en las fichas técnicas y, en su caso otra documentación técnica,
correspondientes.

Más contenido relacionado

La actualidad más candente

S10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
S10_ESPECIALIDAD INSTALACION DE GAS (1).pptxS10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
S10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
GabrielCampuzanoQuis
 
Abastecimiento de agua redes de distribución de agua para consumo humano
Abastecimiento de agua redes de distribución de agua para consumo humanoAbastecimiento de agua redes de distribución de agua para consumo humano
Abastecimiento de agua redes de distribución de agua para consumo humano
Juan Carlos Cruz Piña
 
manual-de-instalacion-sanitaria
manual-de-instalacion-sanitariamanual-de-instalacion-sanitaria
manual-de-instalacion-sanitaria
Arq Rocha
 
Manual tecnico apasco_de_construcción
Manual tecnico apasco_de_construcciónManual tecnico apasco_de_construcción
Manual tecnico apasco_de_construcción
JGIslas
 
Atributos topograficos de las cuencas hidrograficas
Atributos topograficos de las cuencas hidrograficasAtributos topograficos de las cuencas hidrograficas
Atributos topograficos de las cuencas hidrograficas
greghd
 
Sistemas alcantarillado particular
Sistemas alcantarillado particularSistemas alcantarillado particular
Sistemas alcantarillado particular
ppachecoc
 
Hot water-plumbing-system
Hot water-plumbing-systemHot water-plumbing-system
Hot water-plumbing-system
nhmurad
 

La actualidad más candente (20)

obras de captacion.pptx
obras de captacion.pptxobras de captacion.pptx
obras de captacion.pptx
 
LECT. DE PLANOS DE GAS UA 3 VALIDADO.pdf
LECT. DE PLANOS DE GAS UA 3 VALIDADO.pdfLECT. DE PLANOS DE GAS UA 3 VALIDADO.pdf
LECT. DE PLANOS DE GAS UA 3 VALIDADO.pdf
 
LECT. DE PLANOS DE GAS UA 4 VALIDADO.pdf
LECT. DE PLANOS DE GAS UA 4 VALIDADO.pdfLECT. DE PLANOS DE GAS UA 4 VALIDADO.pdf
LECT. DE PLANOS DE GAS UA 4 VALIDADO.pdf
 
S10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
S10_ESPECIALIDAD INSTALACION DE GAS (1).pptxS10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
S10_ESPECIALIDAD INSTALACION DE GAS (1).pptx
 
Guia usuario 2011 CEDAE
Guia usuario 2011 CEDAEGuia usuario 2011 CEDAE
Guia usuario 2011 CEDAE
 
CONCRETO ARMADO - ACERO LONGITUDINAL
CONCRETO ARMADO - ACERO LONGITUDINALCONCRETO ARMADO - ACERO LONGITUDINAL
CONCRETO ARMADO - ACERO LONGITUDINAL
 
Manual
ManualManual
Manual
 
Desague y ventilacion
Desague y ventilacionDesague y ventilacion
Desague y ventilacion
 
Abastecimiento de agua redes de distribución de agua para consumo humano
Abastecimiento de agua redes de distribución de agua para consumo humanoAbastecimiento de agua redes de distribución de agua para consumo humano
Abastecimiento de agua redes de distribución de agua para consumo humano
 
manual-de-instalacion-sanitaria
manual-de-instalacion-sanitariamanual-de-instalacion-sanitaria
manual-de-instalacion-sanitaria
 
Manual tecnico apasco_de_construcción
Manual tecnico apasco_de_construcciónManual tecnico apasco_de_construcción
Manual tecnico apasco_de_construcción
 
Distribución de aguas blancas
Distribución de aguas blancasDistribución de aguas blancas
Distribución de aguas blancas
 
Atributos topograficos de las cuencas hidrograficas
Atributos topograficos de las cuencas hidrograficasAtributos topograficos de las cuencas hidrograficas
Atributos topograficos de las cuencas hidrograficas
 
Informe de campo de aforador sin cuello
Informe de campo de aforador sin cuelloInforme de campo de aforador sin cuello
Informe de campo de aforador sin cuello
 
Sistemas alcantarillado particular
Sistemas alcantarillado particularSistemas alcantarillado particular
Sistemas alcantarillado particular
 
Acueductos ucc 2016 1
Acueductos ucc 2016 1Acueductos ucc 2016 1
Acueductos ucc 2016 1
 
Tema 2. Trazado de Tuberías e Isometría
Tema 2. Trazado de Tuberías e IsometríaTema 2. Trazado de Tuberías e Isometría
Tema 2. Trazado de Tuberías e Isometría
 
Presión de los aparatos domésticos
Presión de los aparatos domésticosPresión de los aparatos domésticos
Presión de los aparatos domésticos
 
Solenoides y pilotos bermad irrigacion
Solenoides y pilotos bermad irrigacionSolenoides y pilotos bermad irrigacion
Solenoides y pilotos bermad irrigacion
 
Hot water-plumbing-system
Hot water-plumbing-systemHot water-plumbing-system
Hot water-plumbing-system
 

Similar a Ponencia: Claves para una correcta ejecución de un sistema SATE

2 timken catalogo-general-rod_esfericos
2 timken catalogo-general-rod_esfericos2 timken catalogo-general-rod_esfericos
2 timken catalogo-general-rod_esfericos
nilson_jair
 
Flexitallic design manual_en_espanol
Flexitallic design manual_en_espanolFlexitallic design manual_en_espanol
Flexitallic design manual_en_espanol
luisenriuqe
 
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOSMANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
Filiberto Mtz
 
Sistema automatizado de marquesinas móviles
Sistema automatizado de marquesinas móvilesSistema automatizado de marquesinas móviles
Sistema automatizado de marquesinas móviles
Diego Eslava
 
Electroerosionadora Hilo | AGUIE CUT-20P
Electroerosionadora Hilo | AGUIE CUT-20PElectroerosionadora Hilo | AGUIE CUT-20P
Electroerosionadora Hilo | AGUIE CUT-20P
IMOCOM1
 

Similar a Ponencia: Claves para una correcta ejecución de un sistema SATE (20)

Manual compactos-termicos-solares-salvador-escoda
Manual compactos-termicos-solares-salvador-escodaManual compactos-termicos-solares-salvador-escoda
Manual compactos-termicos-solares-salvador-escoda
 
Catalogo postensado
Catalogo postensadoCatalogo postensado
Catalogo postensado
 
manual de rodamienos esfericos timken
manual de rodamienos esfericos timkenmanual de rodamienos esfericos timken
manual de rodamienos esfericos timken
 
2 timken catalogo-general-rod_esfericos
2 timken catalogo-general-rod_esfericos2 timken catalogo-general-rod_esfericos
2 timken catalogo-general-rod_esfericos
 
2018 presentacion dicomol
2018 presentacion dicomol2018 presentacion dicomol
2018 presentacion dicomol
 
Flexitallic design manual_en_espanol
Flexitallic design manual_en_espanolFlexitallic design manual_en_espanol
Flexitallic design manual_en_espanol
 
Instrucciones de Montaje para el Colector CPC
Instrucciones de Montaje para el Colector CPCInstrucciones de Montaje para el Colector CPC
Instrucciones de Montaje para el Colector CPC
 
Ductsox dsx design manual spanish
Ductsox dsx design manual spanishDuctsox dsx design manual spanish
Ductsox dsx design manual spanish
 
Ramon Vizcaino - Catalogo industrial cold pak
Ramon Vizcaino - Catalogo industrial cold pak Ramon Vizcaino - Catalogo industrial cold pak
Ramon Vizcaino - Catalogo industrial cold pak
 
PPT WEBINAR 25-05.pdf
PPT WEBINAR 25-05.pdfPPT WEBINAR 25-05.pdf
PPT WEBINAR 25-05.pdf
 
Mc manual lavadoras
Mc manual lavadorasMc manual lavadoras
Mc manual lavadoras
 
Pack ryt bbas. de turbina vertical
Pack ryt bbas. de turbina verticalPack ryt bbas. de turbina vertical
Pack ryt bbas. de turbina vertical
 
Manual tecnico de paneles de yeso durlock
Manual tecnico de paneles de yeso durlockManual tecnico de paneles de yeso durlock
Manual tecnico de paneles de yeso durlock
 
Instrucciones a calefactor sprinter
Instrucciones a calefactor sprinterInstrucciones a calefactor sprinter
Instrucciones a calefactor sprinter
 
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOSMANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
MANUAL DE INSTALACIÓN DE PANELES SOLARES TÉRMICOS
 
Sistema automatizado de marquesinas móviles
Sistema automatizado de marquesinas móvilesSistema automatizado de marquesinas móviles
Sistema automatizado de marquesinas móviles
 
2019 presentacion dicomol
2019 presentacion dicomol2019 presentacion dicomol
2019 presentacion dicomol
 
Electroerosionadora Hilo | AGUIE CUT-20P
Electroerosionadora Hilo | AGUIE CUT-20PElectroerosionadora Hilo | AGUIE CUT-20P
Electroerosionadora Hilo | AGUIE CUT-20P
 
Catalogo alcance swagelok
Catalogo alcance swagelokCatalogo alcance swagelok
Catalogo alcance swagelok
 
Presentacion iNSPECCIÓN DE HDPE CON TOFD
Presentacion iNSPECCIÓN DE HDPE CON TOFDPresentacion iNSPECCIÓN DE HDPE CON TOFD
Presentacion iNSPECCIÓN DE HDPE CON TOFD
 

Último

S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
samuelsan933
 
sistema de CLORACIÓN DE AGUA POTABLE gst
sistema de CLORACIÓN DE AGUA POTABLE gstsistema de CLORACIÓN DE AGUA POTABLE gst
sistema de CLORACIÓN DE AGUA POTABLE gst
DavidRojas870673
 
Tipos de suelo y su clasificación y ejemplos
Tipos de suelo y su clasificación y ejemplosTipos de suelo y su clasificación y ejemplos
Tipos de suelo y su clasificación y ejemplos
andersonsubero28
 

Último (20)

Presentación Instrumentos de Medicion Electricos.pptx
Presentación Instrumentos de Medicion Electricos.pptxPresentación Instrumentos de Medicion Electricos.pptx
Presentación Instrumentos de Medicion Electricos.pptx
 
Clasificación de Equipos e Instrumentos en Electricidad.docx
Clasificación de Equipos e Instrumentos en Electricidad.docxClasificación de Equipos e Instrumentos en Electricidad.docx
Clasificación de Equipos e Instrumentos en Electricidad.docx
 
422382393-Curso-de-Tableros-Electricos.pptx
422382393-Curso-de-Tableros-Electricos.pptx422382393-Curso-de-Tableros-Electricos.pptx
422382393-Curso-de-Tableros-Electricos.pptx
 
DIAPOSITIVAS DE SEGURIDAD Y SALUD EN EL TRABAJO
DIAPOSITIVAS DE SEGURIDAD Y SALUD EN EL TRABAJODIAPOSITIVAS DE SEGURIDAD Y SALUD EN EL TRABAJO
DIAPOSITIVAS DE SEGURIDAD Y SALUD EN EL TRABAJO
 
Six Sigma Process and the dmaic metodo process
Six Sigma Process and the dmaic metodo processSix Sigma Process and the dmaic metodo process
Six Sigma Process and the dmaic metodo process
 
2. Cristaloquimica. ingenieria geologica
2. Cristaloquimica. ingenieria geologica2. Cristaloquimica. ingenieria geologica
2. Cristaloquimica. ingenieria geologica
 
Tippens fisica 7eDIAPOSITIVAS TIPENS Tippens_fisica_7e_diapositivas_33.ppt
Tippens fisica 7eDIAPOSITIVAS TIPENS Tippens_fisica_7e_diapositivas_33.pptTippens fisica 7eDIAPOSITIVAS TIPENS Tippens_fisica_7e_diapositivas_33.ppt
Tippens fisica 7eDIAPOSITIVAS TIPENS Tippens_fisica_7e_diapositivas_33.ppt
 
S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
S3-OXIDOS-HIDROXIDOS-CARBONATOS (mineralogia)
 
Video sustentación GA2- 240201528-AA3-EV01.pptx
Video sustentación GA2- 240201528-AA3-EV01.pptxVideo sustentación GA2- 240201528-AA3-EV01.pptx
Video sustentación GA2- 240201528-AA3-EV01.pptx
 
CAPACITACIÓN EN AGUA Y SANEAMIENTO EN ZONAS RURALES
CAPACITACIÓN EN AGUA Y SANEAMIENTO EN ZONAS RURALESCAPACITACIÓN EN AGUA Y SANEAMIENTO EN ZONAS RURALES
CAPACITACIÓN EN AGUA Y SANEAMIENTO EN ZONAS RURALES
 
sistema de CLORACIÓN DE AGUA POTABLE gst
sistema de CLORACIÓN DE AGUA POTABLE gstsistema de CLORACIÓN DE AGUA POTABLE gst
sistema de CLORACIÓN DE AGUA POTABLE gst
 
1. Equipos Primarios de una Subestaciones electricas
1. Equipos Primarios de una Subestaciones electricas1. Equipos Primarios de una Subestaciones electricas
1. Equipos Primarios de una Subestaciones electricas
 
G4 - CASO DE ESTUDIO - VOLUMEN DE UN RESERVORIO (1).pptx
G4 - CASO DE ESTUDIO - VOLUMEN DE UN RESERVORIO (1).pptxG4 - CASO DE ESTUDIO - VOLUMEN DE UN RESERVORIO (1).pptx
G4 - CASO DE ESTUDIO - VOLUMEN DE UN RESERVORIO (1).pptx
 
5. MATERIALES petreos para concreto.pdf.
5. MATERIALES petreos para concreto.pdf.5. MATERIALES petreos para concreto.pdf.
5. MATERIALES petreos para concreto.pdf.
 
Estadística Anual y Multianual del Sector Eléctrico Ecuatoriano
Estadística Anual y Multianual del Sector Eléctrico EcuatorianoEstadística Anual y Multianual del Sector Eléctrico Ecuatoriano
Estadística Anual y Multianual del Sector Eléctrico Ecuatoriano
 
Arquitecto cambio de uso de suelo Limache
Arquitecto cambio de uso de suelo LimacheArquitecto cambio de uso de suelo Limache
Arquitecto cambio de uso de suelo Limache
 
27311861-Cuencas-sedimentarias-en-Colombia.ppt
27311861-Cuencas-sedimentarias-en-Colombia.ppt27311861-Cuencas-sedimentarias-en-Colombia.ppt
27311861-Cuencas-sedimentarias-en-Colombia.ppt
 
Tipos de suelo y su clasificación y ejemplos
Tipos de suelo y su clasificación y ejemplosTipos de suelo y su clasificación y ejemplos
Tipos de suelo y su clasificación y ejemplos
 
docsity-manzaneo-y-lotizacion para habilitacopm urbana
docsity-manzaneo-y-lotizacion para habilitacopm urbanadocsity-manzaneo-y-lotizacion para habilitacopm urbana
docsity-manzaneo-y-lotizacion para habilitacopm urbana
 
GUIA DE SEGURIDAD PARA VENTILACION DE MINAS-POSITIVA.pdf
GUIA DE SEGURIDAD PARA VENTILACION DE MINAS-POSITIVA.pdfGUIA DE SEGURIDAD PARA VENTILACION DE MINAS-POSITIVA.pdf
GUIA DE SEGURIDAD PARA VENTILACION DE MINAS-POSITIVA.pdf
 

Ponencia: Claves para una correcta ejecución de un sistema SATE