2. INSPUR Self-developed Cloud Computing Products and Platforms
Mission Critical
computing
Hyper scale
computing
TSK1 SmartRack
Storage computing
Mass storage
Enterprise
computing
X86 servers
Infrastructure
In-Cloud OS In-Cloud IOP
In-Cloud
DroP-Data
Resource
Virtualization
Big Data
process
Internet data
In-Cloud Platform
Based on Computing
Cloud Center
4. 4
Inspur Yingxin N# # # ## M#
NP: Tower server
NF: Rack server
NX: Blade server
3: one socket
5: two sockets
8: four sockets
Height (U)
Market positioning
Generation
Server Naming Rule
NF5280M4
Rack server , 2 sockets , height is 2U , aim to high end market , 4th
generation product
5. X86 Product line
Rack Server
NF8460M3
1 Processor 2 Processors 4 Processors
NF5270M4
NP3020M3
NP5540M3
NF5280M4 NF8480M4
NF5180M4
8+ processors
TS860
NX8840
NF8460M4
NF5170M4 NF8480M3
I8000
NX5440M4
I9000
NX5460M4
NX8880M4
Tower Server
NP5540M4NP3020M4
Blade Server
P8000
11. 1x E3-1200 v3 processor
8x 3.5”SATA
4x DIMMs
300W or 500W
Power supply
1x PCI graphics card
NP3020M3 main components
12. 2x 1Gb RJ45 NICs
VGA port
Serial port
2 USB
PS/2
2 USB
NP3020M3 front & back view
13. 1x PCI-Ex4 slot
3x PCI slots
1x PCI-Ex16 slot
SATA interface
4x DIMMs
2x 1Gb RJ45 NICs
VGA port
2 USB
1x PS/2
1x serial port
NP3020M3 motherboard
14. Processor Intel® Xeon® E3-1200 v3 series CPU, Intel® Pentium® G3220/G3420
Memory 4 DIMMs, DDR3 ECC unbuffered 1333/1600MHz
Hard drive Standard configuration: 2x SATA hard drives, up to 8x SATA hard drives through expansion card
PCI slots
1x PCI-E x16
1x PCI-E x4
3x PCI
I/O
Front: 2x USB
Rear: 1x VGA port, 1x PS/2 port, 1x serial port, 2x RJ45 NICs
Built-in: 1x serial port, 1x USB
Disk controller Onboard SATA controller, 8-channel SAS 6Gb disk controller (PCI card)
NIC Onboard 2x 1Gb
Power supply Single power 300W
OS
Microsoft Server 2008 R2
Windows 8 ultimate 64Bit
Windows 7 ultimate sp1 64Bit
Red Hat Enterprise Linux 6 U3 64Bit
Graphics card K600, K2000, Quadro 410
Voltage 180V~264V ( single power ) 50HZ
Environmental
requirement
Working temperature:10℃-35℃
Working humidity : 35%-85%
Chassis 200mm(W) x 435mm(H) x 510mm(D)
NP3020M3 specification
15. 1 VGA port, 1
serial port
2*RJ45
4 USB port
NP5540M3 front & back view
16. 12 DIMMs, up to 384GB 500W single PSU, optional 500W
redundant PSU, 800W single PSU
E5-2400v2 series processor
Up to 2*PCI-E3.0 x16,
3*PCI-E3.0x8 , 1 PCI
Up to 4*3.5”or 16*2.5”
SAS/SATA
NP5540M3 motherboard
18. Processor Intel® Xeon® E5-2400v2 series, 10M-20M cache
Chipset Intel ® C600 server chipset
QPI bus rate 6.4GT/S-8.0GT/S
Memory 12 DIMMs, DDR3-1600MHz, up to 384GB
Hard drive 4*3.5”or 16*2.5” SAS/SATA
PCI slots 2 PCI-E 3.0 x16; 3 PCI-E 3.0 x8; 1 PCI
I/O
Front: 2x USB
Rear: 4x USB, 1x VGA port, 1x PS/2 port, 1x serial port, 2x RJ45 port
Built-in: 1x serial port, 1x USB
Hard drive controller 6-port SATA controller, 4 SATA II , 2 SATA III RAID 0,1,10,5
Environmental
requirement
Working temperature:10℃-35℃
Working humidity : 35%-80%
NIC Onboard 2x 1Gb
Power supply Single 500W , optional dual 500W, single 800W
OS
Windows 2003 Enterprise with SP2 32/64bit; Microsoft Windows Server 2008 SP1 32/64bit; Red Hat Enterprise
Linux 5.5 32/64bit; Red Hat Enterprise Linux 5.6 32/64bit; Red Hat Enterprise Linux 6.1 32/64bit; Red Hat
Enterprise Linux 6.2 32/64bit
SuSE Linux Enterprise Server 11.2 32/64bit
Graphics card Onboard 16M controller
NP5540M3 specification
30. Processor 2 Intel® Xeon® E5-2600 v3 processors
Memory
24 DIMM DDR4 ( RDIMM/LRDIMM ) , DDR4-2133, up to 1536GB (when
64GB per DIMM)
HDD 8x 2.5”/4x 3.5”+2 SSD
PCI-E
1x PCI-E x8+x1 slots( network card only)
2x PCI-E x16 slots (x16 signal), support 2 full height half length cards thru
1PCI-E Riser card
RAID Optional RAID 0/1/5/6/10/50/60
NIC Onboard Intel I350 dual 1Gb network port
Power supply 550W/800W 1+1 Redundant, 80+ Pt AS/AA mode
Power voltage 220/240/-48V
Environmental
requirement
Working temperature:10 -35℃ ℃
Working humidity : 35%-80%
NF5180M4 specification
31. 8 *2.5“hot swap
hard drives
VGA
2* USB 3.0 indicator
4 *3.5“
hot swap hard drives
• The same front-panel design
Support panels with lock
• Up to 8 *2.5“ hard drive
2*SSD
NF5170M4/NF5180M4
32. VGA
IPMI port
2*USB 3.0
2*PCI-E 3.01+1 PSU
NF5180M4
NF5170M4
VGA
2*USB 3.04*1Gb port
1+1 PSU 2*PCI-E 3.0
2* 10Gb port
Network daughter
card
2* 1Gb port
NF5170M4/NF5180M4
35. NF5280M4 series:
High specification, high performance and optimal
usability
NF5270M4 series:
Best choice in terms of mainstream specification and
cost/performance ratio
2U2-socket Rack Server
39. Processor 2 Intel® Xeon ® E5-2600V3 processors
Memory 20 DIMM, DDR4-2133, up to 640GB ( when 32 GB per DIMM).
HDD
Front: up to 24 *2.5” hot swap SATA/SAS or SSD; 12*3.5” hot swap SATA/SAS
Rear: up to 2* 2.5”hot swap SATA/SAS or SSD
PCI-E 6 PCI-E slots, including 4 PCI-E X8 and 2 PCI-E X16
RAID Optional RAID 0/1/5/6/10/50/60 and BBU
NIC 2-port 1Gb
Power supply 550/800/, 1+1 Redundant, 80+ Pt AS/AA mode
Power voltage 110-240V
Environmental
requirement
Working temperature:10 -35℃ ℃
Working humidity : 35%-85%
NF5270M4 specification
40. Front hot swap
HDD
Safety lock
Backlit indicator lightAsset tag
HDD information label
Toolless rail locker
Front panel
NF5280M4
41. 6 full height PCI-E slots
Optional network daughter card
Rear 2.5” SATA/SSD
up to 4
Optional various power
supply USB 3.0
Onboard 2*1Gb
IPMI port
NF5280M4
44. Processor 2 Intel® Xeon ® E5-2600V3 processors
Memory 24 DIMM, DDR4-2133, up to 1536GB ( when 64 GB per DIMM).
HDD
Front: up to 24 *2.5” hot swap SATA/SAS/SSD or 4/8/12*3.5” hard drives
Rear: up to 4* 2.5”hot swap SATA/SAS/SSD
PCI-E Up to 6 PCI-E 3.0 x8 and 1 PCI-E for network card only
RAID Optional RAID 0/1/5/6/10/50/60 and BBU
NIC Onboard 2-port 1Gb
Power supply 550/800/, 1+1 Redundant, 80+ Pt AS/AA mode
Power voltage 110-240V
Environmental
requirement
Working temperature:10 -35℃ ℃
Working humidity : 35%-85%
NF5280M4 specification
47. Higher computing power
•60 computing cores—1.5 times
•37.5MB L3 cache—1.25 times
•8GT/s QPI bus—1.25 times
•2TB memory expansion—2 times
•1600MHz DDR3—1.5 times
More reliable system operation
•Greatly lower operating noise
•Cooling unit dust filtration
•OLED, LCM, power failure query
•Power consumption real-time monitoring with upper
limit
•Self-developed K-Unix supported
Fully improved scalability
•12x PCI-E expansion slots—2.4 times
•PCI-E 3.0 bus bandwidth—2 times
•Onboard 4x 1Gb NIC—2 times
•MIC or GPU co-process card
Virtualization Database Business analysis Treatment of online transaction Heterogeneous computing
NF8460M3
49. 4 x4 PCI-E; 5 x8 PCI-E; 3 x16PCI-E
1 VGA
1 serial port PSU
1 management port
4 USB port
4 *1Gb RJ45
NF8460M3
50. Processor 4 Intel ® Xeon ® processors of E7 v2 Series
Chipset Intel ®C602 Series Chipset
RAM 32 memory slots, expandable to 2TB memory in maximum
Hard Disk Controller Externally inserted with high-performance SAS or SAS Raid cards, support SAS 12G
RAID 1/0/10/5/50/6/60, 1GB / 2GB / 4GB cache
Storage Up to16*2.5’’ hot-swap SAS / SATA / SSD
I / O Expansion Slots 12 PCI-E 3.0 slots (4 x4 PCI-E; 5 x8 PCI-E; 3 x16PCI-E)
Integrated I / O Ports
Front port: 2 USB ports and 1 VGA ports
Rear ports: 4 RJ45 gigabit network port, 1 RJ45 gigabit management port, 1 rear VGA port, 4
USB2.0 ports and 1 serial port
Network Controller
Integrated with 4 Gigabit network ports
Support advanced features, such as Wakeup on LAN , network redundancy, load balancing, etc.
Power supply
Support 4*700W power supply modules in maximum, with redundant modes 2 + 2 + 2 or 3 + 1 as the
alternative
NF8460M3 specification
51. LCD monitoring
8 hot swap hard drives
4 NVMe hard drives
Toolless lockerInformation label
51
NF8480M3
52. PDU hot swap power module
IO
Basic IO module
1Gb RJ45
USB
VGA port
NF8480M3
54. Power module
hot swap power module
7+1 redundant
hot swap fan
Basic IO module
Expand IO module
54
NF8480M3
55. Processor
4*Intel E7-4800 v2 or Intel E7-8800 v2 processor
Memory 96 Dimms, up to 6TB
DDR3 1066/1333/1600 MHz
Single ram capacity : 8G/16G/32G/64G
IO Basic IO module :
Slot0 ( CPU1 ): PCI-E x16 in x16 , full height half length
Slot1 ( CPU1 ): PCI-E x8+x1 , full height half length
Scalable IO module :
Slot0 ( CPU3 ): PCI-E x8 in x16 , full height half length, hot swap
Slot1 ( CPU3 ): PCI-E x8 in x16 , full height half length, hot swap
Slot2 ( CPU3 ): PCI-E x8 , full height half length, optional full height full length
( support GPU )
Slot3 ( CPU3 ): PCI-E x8 , full height half length, optional full height full length
Slot4 ( CPU2 ): PCI-E x8 in x16 , full height half length, optional full height full- length ( support GPU )
Slot5 ( CPU2 ): PCI-E x8 , full height half length, optional full height full length
Slot6 ( CPU2 ): PCI-E x8 in x16 , full height half length, optional full height full length
Slot7 ( CPU2 ): PCI-E x8 , full height half length, optional full height full length
Slot8 ( CPU0 ): PCI-E x8 in x16 , full height half length, optional full height full length
Slot9 ( CPU0 ): PCI-E x8 , full height half length, optional full height full length
Storage and control module :
dedicated slot for Raid card ( CPU0 ): PCI-E x8 , half height half length
dedicated slot for PCI-E Switch ( CPU1 ): PCI-E x8 , Mezz
HDD
2.5” SAS/SATA/SSD/NVMe hot swap hard drive , and 4 NVMe at the maximum
55
NF8480M3 specification
56. NIC Basic IO module integrated with 4 1Gb NIC ( RJ45 )
Power
Supply
Platinum high efficiency hot swap power module
4*800W power module, optional 2+1, 2+2, 3+1 redundancy mode
Management Storage and control module standard configure OLED LCD
Standard IPMI port
Ethernet-based KVM
Collection of system operating log and failure diagnosis
FW distance upgrade in batch, voltage conversion module
monitoring, hard disk management
Thermal distribution monitoring of all components, multi-level heat
dissipation adjusting strategy
Support Inspur Ruijie management suite
56
NF8480M3 specification
58. Inspur TS860 is composed by four modules such as computing module, storage
module, IO module and power supply module
Fully modular design Fully front &back
maintenance
Tool-Free disassembly Cable-Free
Design
TS860
59. 4*processors
(E7-4800 v2/E7-8800 v2 series
processors)
8*memory boards
(each memory board supports 12
DIMMs)
Each computing module
3*ultra-silence system fans
(front hot swappable)
Computing module
60. 10
( for RAID Card Only )
2.5“ HDx16
Expander Card
Storage module
62. One group of power supply
module (1 PDU+4*800W power
supply)
One group of power supply module
(1 PDU+4*800W power supply)
Each PDU is corresponding
to 4 power supplies in one
group
Support plug redundancy
design in future
Redundant mode: 5+1,6+1 or 7+1 are recommended
Power supply
63. Form factor/height Rack-mounted/8U
Processor 8 Intel ® XEON™ E7-4800 v2/E7-8800 v2 series processors
Memory Up to 192 DIMMs, 12TB memory
HDD Up to 16 * 2.5”hot swap SAS/SATA/SSD
I/O 26 standard PCI-E 3.0 slots
NIC 4*1Gb
Power supply 8*800W super platinum power supplies, N+M/N+N
Monitoring and
management
Provide dedicated Ethernet management port
Support Inspur Ruijie management kit
Support management system redundancy
Configure optical channel status display screen used for management and
monitoring, optional high definition intelligent management system
OS supported
Windows Server
Red Hat Enterprise Linux
SUSE Linux Enterprise
CentOS Linux
VMware ESXi
Kylin Linux
Oracle Solaris
Inspur K-UX, etc.
Power input 100VAC-240VAC , 240VDC
Chassis size 830mm (L), 444mm (W), 352mm (H)
TS860 specification
65. Sistema de servidor blade de Arquitectura Convergente ——Inspur I9000—Vi
sta frontal
12U
Hasta 6 hostswap
fuente de poder
redundantes
Hasta 8 nodos de
computación de hoja
completa
Hasta 16 nodos
de computación
de media hoja
66. Sistema de servidor blade de Arquitectura Convergente Inspur I9000—
Vista trasera
Hasta 10
módulo de
refrigeración
Hasta 2
módulo de PDU
Hasta 8
módulo de
IOBox
Hasta 4
módulos de
comunicación
Hata 2 módulos de
administración
67. • 1 NX8880M4=650W
• 1 NX5460M4=500W
Puente de poder:
• 1 fuente de poder=3000W,
• Cantidad máxima: 6
• Redundancia.
• El modo redundante: N+N o N+M
.
• 1-3 fuente de poder=1 PDU
• 4-6 fuente de poder=2 PDU
(Ejemplo: 1+1 redundancia puede soportar
4 NX8880M4 ó 6 NX5460M4)
Hasta 6
hotswap Fuente de
poder
Hasta 8
hoja
comleta
Hasta
16
media
hoja
Hasta 2
módulo de
PDU
Sistema de servidor blade de Arquitectura Convergente I9000Configura
limentación
68. IOBox
1-4
IOBox
5-8
• Se ofrecen 8 módulos IOBox, cada uno ofrece ranur
a de expansión estándar de media altura y largo me
dio PCIE 3.0x8; los dos nodos de largo medio el mis
mo lado se muestran en la imagen a la derecha
• Con el IOBox, el usuario puede tener tarjetas están
dares de expansión como tarjetas de red, tarjetas
HBA, y tarjetas IB, sin tener que usar módulos pas
s-through, y evita la exclusión entre el módulo
de pass-through y el módulo de conmutación. Es la
solución más flexible de pass-through.
1 2
1
2
Sistema de servidor blade de Arquitectura Converg
ente Inspur I9000——IOBox
69. Diseño de Alta Gama
NX5460M4 soporta 2 Procesadores
Intel de la serie E5-2600 v3
24 DDR4 Dimms de memoria.
CPU 1
CPU 2
24 DDR4
Dimms
Hot swap
HDD
Handle
Botón de encendido
Botón de ID 2*USB3.0
VGAIndicador de falla
Sistema de servidor blade de Arquitectura Convergente
Inspur I9000——Configuración NX5460M4
2 Tarjetas
SAS/SATA/NVMe
Tarjeta SAS Raid
(SAS Mezz
Mezz card 2
Mezz card 1
70. Disco duro
interno de
Msata
Interfaz de
expansión de
conexión externa
PCIE 16x
(reservada
Ranura de red de la
tarjeta hija Mezz
Todas las ranuras y las
interfaces no se excluyen
mutuamente
Mezz1 CPU1
Módulo de
intercambio
de 1 y 3
Mezz2 CPU2
Módulo de
intercambio
de 2 y 4
Sistema de servidor blade de Arquitectura Convergente
Inspur I9000—Configuración NX5460M4
71. • Módulos de intercambio convergente de 1Gb /10Gb (Galaxywind)
Puertos
ascendentes
8x1Gb RJ45, 8x10Gb SFP+, 2x40Gb QSFP , diseño de módulo, soporte de pila
cada puerto de 10Gb, 1×RJ45 para administrar y mantener
Puertos
descendente
16x1Gb link conecta a 1Gb LOM de Cuchilla, 32x10Gb link conecta 10Gb Mezz
de Cuchilla. Ofrece la conexión con I2C GbE y GPIO de módulos de
administración de redundancia
Función de
intercambio
Soporta intercambio entre segundo nivel y tercer nivel estándar (IPv4 & IPv6).
Soporte funciones de características de centro de datos. Puerto de 10Gb soporte
función de características de FCoE. Puerto de 40GE para apilado.
Función de
administración
SNMP v1/v2/v3, Telnet, Console, MGMT, WEB, RMON, SSHv1/v2, FTP/TFTP
administración de carga y descarga, soporte reloj de NTP, Syslog, SPAN/RSPAN
y análisis de flujo de IPFIX.
Configura red directamente por módulos de administración, autorización de FW.
Ofrece interfaz de monitoreo de switches ( temperaturas, presión electrónica,
diarios e información de alarma) , Información de alarma puede notificar a
módulos de administración. Acepta inicio, apagado y reinicio de módulos de
intercambio por medio del módulo de administración. Configura el módulo de
intercambio según módulo de administración (línea de comando e interfaz de
gráfica)
Ventilador Dos grupos de ventiladores intercambiables en caliente
1 2 3 4
Propone que configuran en ranuras 1 y 3 de switches de chasis trasero, y proporciona a
cada nodo de media altura con una interfaz de 1 Gb y una interfaz de red de 10 Gb,
también se puede configurar en ranuras 2 y 4 de switches, pero en este caso sólo
pueden proporcionar a cada nodo de media altura con una tarjeta interfaz de 10Gb.
Nota: configuran dos módulos para soportar una tarjeta interfaz dual 1Gb de cada
nodo de media altura e interfaz de dual 10Gb de tarjetas hijas Mezz1
Sistema de servidor blade de Arquitectura
Convergente Inspur I9000
Descripción
1 1-8 puertos RJ45
2 1-4 puertos SFP+
3 5-8 puertos SFP+
4 Módulo , Soporte 1-2 puertos QSFP
5 VENTILADORES (FAN1 & FAN2)
6 Puertos RJ45 (Administración y
Comunicación estánder son RS232 , tipo
de interfaz RJ-45 , sin indicador)
7 LED de estado de Switch
8 LED de estado de Switch
72. Sistema de servidor blade de Arquitectura C
onvergente Inspur I9000
Puerto de enlace
ascendente
Interfaz de 16x10Gb SFP+, Módulo de extensión de 4x40Gb QSFP, con
soporte de apilamiento, cada puerto puede soportar la dirección 4 10Gb
Interfaz de administración y mantenimiento de 1×RJ45
Puerto de enlace
descendente
16 puertos de 10Gb conecta a Mezz de Gigabit en cuchilla
Ofrece un link a I2C GbE y GPIO del módulo de administración y
mantenimiento
Función de
conmutación
Soporta el intercambio estándar de segundo y tercer nivel IPv4 & IPv6),
función especial de centro de datos, FCoE 16 puertos de enlace
ascendentes), puertos FC (entre los 16 puertos de enlace ascendente
Función de
administración
-Ofrece administración para carga y descarga de documentos SNMP
v1/v2/v3 Telnet Console MGMT WEB RMON SSHv1/v2 FTP/TFTP, soporta
reloj NTP, soporta Syslog, soporta SPAN/RSPAN, soporta análisis de datos
de IPFIX.
-Puede ser gestionado la configuración de internet y la renovación FW
directamente por el módulo de administración.
-Ofrece interfaz de administración para supervisión sobre switch
(información de temperatura, voltaje, diario, alarma) y la alarma puede
notificar al módulo de administración.
-Soporta el inicio, apague y reinicio del módulo de conmutación a través
del módulo de administración.
Puede configurar el módulo de conmutación a través del módulo de
administración (línea de comandos e interfaz de administración)
Ventilador 2 grupo de ventiladores de intercambio en caliente.
• Módulo de conmutación de 10 Gb Star-Net
No. Descripción de puerto
1 SFP+ puertos 1-16
2 Puertos QSFP 1-2
3 Puertos QSFP 3-4
4 Puerto RJ45 (Administración)
5 Indicador LED Estado
6 Indicador LED encendido
7 VENTILADORES (FAN1&FAN2)
1 2 3 4
La ubicación de configuración están en los puntos 1,2,3,4 en las ranuras de switch en la
parte atrás del host, ofreciendo una interfaz de 10 Gb para cada nodo de altura media.
Atención: Cuando se instala este módulo en las ranuras 1 y 3, el puerto de 1Gb en la
tarjeta de la cuchilla no puede ser utilizado, se aconseja configurar en las ranuras 2 y 4.
73. Sistema de servidor blade de Arquitectura C
onvergente I9000Módulo FC de 16G de conmutación fusión (Brocade)
Puerto de
enlace
ascendente
Interfaz de 16x SFP+ FC, soportando la velocidad de
4/8/16Gb
Puede servir como F_ports, E_ports puerto de estilo
extensión), y puede servir como N_ports bajo el modo de
conexión a puerto de enlace.
Interfaz de administración 1×PJ45 de serie, sirve para
administración y mantenimiento.
Puerto de
enlace
descendente
32 × full duplex 16Gb FC interfases
El puerto de enlace descendente es F_ports.
Ofrece link I2C GbE y GPIO al módulo redundante de
adminstración.
Ventilador 2 grupo de ventiladores hot-swap No Description
1 Puertos SFP+ 1-4
2 Puertos SFP+ 5-8
3 Puertos SFP+ 9-12
4 Puertos SFP+ 13-16
5 VENTILADORES (FAN1 & FAN2)
6 Puertos PJ45
(Comunicación estándar para
RS232, Interfaz tipo RJ-45, sin
indicador)
7 Indicador LED de Estado
8 Indicador LED Encendido
1 2 3 4
Se aconseja tomar los puntos 2 y 4 en las ranuras de switch en la parte
posterior del host como sitio de configuración, y cada módulo puede
ofrecer una interfaz de tarjeta secundaria FC SAN para cada nodo de
media altura. También se pueden configurar los puntos 1 y 3, pero en
este caso no soporta la extensión Ethernet en la cuchilla, sólo puede
utilizar el switch de 10 Gb en las ranuras 2 y 4 para colaborar con la
tarjeta secundaria de 10 Gb de cuchilla o colaborar con la tarjeta
Ethernet estándar en IOBox con el fin de tener extensión de Ethernet.
75. K1 910
8 CPU 64 core
K1 930
32 CPU
128 Core
K1 950
32 CPU
256 Core
TSK1
76. Architecture : Tightly coupled CC-NUMA
CPU : Support 32 CPU Max. 256 core
Ram : support to 4TB Max.
Hardware partition:1~8, support any combination
from 4-32 CPU
I/O : 48 PCI-E slot
OS : Inspur K-UX
TSK1