1. Asma y EPOC: Ni Junt@s Ni Revuelt@s
(Si no todo lo contrario)
Josep Morera i Prat
Granada, 9 de Junio de 2010
2. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
3. Principio de la Confusión
Kraft M. DOES DISTINCTION BETWEEN
ASTHMA AND COPD MATTER?
…Therefore, I implore you not to ask what your
country can do for you, but what you can do for
your patients!...
Am J Respir Crit Care Med,2006; 174: 238–244.
5. Principio de la Confusión
DEFINICIÓN
Chronic Obstructive Pulmonary Disease (COPD) is a preventable and
treatable disease with some significant extrapulmonary effects that may
contribute to the severity in individual patients. Its pulmonary component
is characterized by airflow limitation that is not fully reversible. The
airflow limitation is usually progressive and associated with an
abnormal inflammatory response of the lung to noxious particles or
gases.
Rabe KF, Hurd S, et al. Global Strategy for the Diagnosis, Management, and Prevention of
Chronic Obstructive Pulmonary Disease: GOLD Executive Summary. Am J Respir Crit
Care Med. 2007;176(6):532-55.
6. Principio de la Confusión
DEFINICIÓN
Is a chronic inflammatory disorder of the airways in which many cells
play a role, in particular mast cells, eosinophils, and T lymphocytes. In
susceptible individuals this inflammation causes recurrent episodes of
wheezing, breathlessness, chest tightness, and cough particularly at
night and / or in the early morning. These symptoms are usually
associated with widespread but variable airflow limitation that is at
least partly reversible either spontaneously or with treatment. The
inflammation also causes an associated increase in airway
responsiveness to a variety of stimuli.
www.ginasthma.org
7. Principio de la Confusión
EPOC: NOSOLOGÍA
ENFERMEDAD 4 Causa - Etiología
S 3 Desorden Funcional
Í Característico
N
D 2 Lesión Anatómica
Característica
R
O
M 1 Descripción Clínica
E
NO SE MENCIONA TABACO NO SE MENCIONA ALERGIA O MEDIACIÓN POR IgE
Basado en J. G. Scadding.
Principles of definition in medicione. Lancet, 1959; 1: 323-325 .
Meaning of diagnostic terms in bronchopulmonary disease. BMJ, 1963; 2: 1425-1430.
The semantics of medical diagnosis. Niomed. Comput, 1972; 3: 83-90.
Helath and disease: what can medicine do for philosophy?. J. Med. Ethics, 1988; 14: 118-124.
Definition on asthma. In: Weiss EB, Stein M. Editors. Bronchial asthma, mechanisms and therapeutics, 3erd ed. Boston: Litle Brown; 1993. p.1-13.
8. Principio de la Confusión
Causas de Dificultad: Diagnóstico Diferencial
El asma crónico puede cursar con obstrucción crónica al flujo
aéreo.
El asma crónico puede cursar con pérdida acelerada de FEV1.
Aprox. El 30% de los asmáticos crónicos, fuman.
El asmático fumador tiene peor evolución y mayor resistencia al
tratamiento.
El tabaco no es la única causa de mala evolución del asma.
Lange P, et al. N Engl J Med. 1998; 339(17): 1194-200.
James AL, et al. Am J Respir Crit Care Med. 2005; 171(2): 109-14.
Chaudhuri R, et al. Am J Respir Crit Care Med. 2003; 168(11): 1308-11.
Gibson PG, Simpson JL.Thorax. 2009; 64(8): 728-35.
10. Principio de la Confusión
16% Obstrucción
228 43% Reversible
2133 a
41% Curación
11. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
12. No Parece Tan Difícil
Differences in Airway Inflammation in Patients with Fixed
Airflow Obstruction Due to Asthma or Chronic Obstructive
Pulmonary Disease
EPOC Asma
M. Fabbri, et al. Am. J. Respir. Crit. Care Med. 2003;167 418-424
13. No Parece Tan Difícil
Differences in Airway Inflammation in Patients with Fixed
Airflow Obstruction Due to Asthma or Chronic Obstructive
Pulmonary Disease
M. Fabbri, et al. Am. J. Respir. Crit. Care Med. 2003;167 418-424.
14. No Parece Tan Difícil
Área bajo ROC
Revers. broncodilatadores 0.71
Revers. corticoides 0.73
DLCO 0.66
KCO 0.65
VK 0.63
PaO2 0.61
% Eosinófilos en BAL 0.95
% Eosinófilos en esputo 0.88
NO exhalado 0.86
Punto de corte eosinófilos en esputo 4.6%
Punto de corte NO exhalado 16 ppb
M. Fabbri, et al. Am. J. Respir. Crit. Care Med. 2003;167 418-424
15. No Parece Tan Difícil
Hombres Mujeres
Am J Respir Crit Care Med. 2005; 171(2):109-14.
16. No Parece Tan Difícil
N Engl J Med, 1998;339:1194-200.
17. No Parece Tan Difícil
E RS
M OK
NS
NO
=
E RS
M OK
-S
EX
N Engl J Med, 1998;339:1194-200.
18. No Parece Tan Difícil
Eur Respir J 2007; 30: 452–456
Proc Am Thorac Soc Vol, 2007; 4: 591–596.
19. No Parece Tan Difícil
SELF SELECTION
OR
Smoking Initiation Favouring quitting
NO ENTRAN EN ENSAYOS CLÍNICOS !!
Eur Respir J 2000; 15: 470-477.
20. No Parece Tan Difícil
Am J Respir Crit Care Med, 2003; 168; 1308–1311.
21. No Parece Tan Difícil
Am J Respir Crit Care Med, 2009; 180: 1170–1178.
22. No Parece Tan Difícil
Am J Respir Crit Care Med, 2009; 180: 1170–1178.
23. No Parece Tan Difícil
Am J Respir Crit Care Med, 2009; 180: 1170–1178.
24. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
31. Nuevas Tecnologías
Thiberville L, et al. Human in vivo fluorescence microimaging of
the alveolar ducts and sacs during bronchoscopy. ERJ.
2009;33(5):974-85.
35. Nuevas Tecnologías
Results: Mean (SD) RBM thickness was not signifi cantly different
between asthma and COPD 5.5 (1.3) vs 6.0 (1.8) μm, but signifi cantly
larger than in their healthy counterparts, ie, 4.7 (0.9) and 4.8 (1.2) μm,
respectively. Collagen I and laminin stained signifi cantly stronger in
asthma than in COPD. Tenascin stained stronger in asthma than in
healthy controls of similar age, and stronger in COPD controls than in
asthma controls (p 0.05).
Liesker JW, et al. International Journal of COPD 2009:4 127–135.
36. Nuevas Tecnologías
Detection of wheezing during maximal forced
exhalation in patients with obstructed airways.
Fiz J.A., et al. Chest, 2002; 122: 188-191.
37. Nuevas Tecnologías
Detection of wheezing during maximal forced
exhalation in patients with obstructed airways.
16
12
Wheezes number
8
4
±Std. Dev.
±Std. Err.
0
Controls COPD Asthma Mean
Groups
p<0.004 (Anova)
Fiz J.A., et al. Chest, 2002; 122: 188-191.
38. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
39. También Asma Sistémica
y ¿Qué hay de los Gemelos?
Chrurg Strauss
NEC
Inf. Eos. Próstata
Modificado de: Boulet LB, ERJ, 2009; 33: 897-906.
42. También Asma Sistémica
y ¿Qué hay de los Gemelos?
Thomsen SF, et al. Risk factors for asthma in young adults: a co-twin
control study.
Allergy. 2006; 61(2): 229-33.
Willemsen G, et alHeritability of self-reported asthma and allergy: a
study in adult Dutch twins, siblings and parents.
Twin Res Hum Genet. 2008; 11(2): 132-42.
Biochem. Soc. Trans. (2009) 37, 814–818.
Am J Respir Crit Care Med, 2007; 176: 1281–1288.
43. También Asma Sistémica
y ¿Qué hay de los Gemelos?
Bouzigon, et al. N Engl J Med 2008; 359: 1985-94.
46. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
47. Si no Todo lo Contrario
Radiology 1990; 175:715-719
48. Si no Todo lo Contrario
34% 31% 33%
Mariotti F et al. Congress. Florencia, December 2007
49. Si no Todo lo Contrario
Agujero de Ozono
Freones = Clorofluorocarbonados
(freón 11) CFCl3 CFCl2 + Cl
Cl + O3 ClO + O2
O3 + O (1 molécula de Cl, puede
destruir 100.000 de moléculas de O3)
http://es.wikipedia.org/wiki/Agujero_de_ozono
Montreal Protocol [Accessed 2002, Apr 19] on line. Available from:
www.unep.org/ozone/pdf/montreal-protocol2000.pdf.
50. Si no Todo lo Contrario
If you have library access to old copies of Nature (try inter-library
loan), the original paper on the theory is Rowland and Molina
[Nature, 249, 810 (1974)].
51. Si no Todo lo Contrario
Tecnología Modulite: características
• Aerosol en solución basado en el propelente HFA-134a
• Permite reducción de la dosis (partículas extrafinas)
• Menor velocidad de la nube de aerosol
– Menor depósito orofaríngeo
– Mayor depósito pulmonar
– Mayor tiempo para la inhalación
– Menor necesidad de coordinación
• No precisa agitación antes de su uso
52. Si no Todo lo Contrario
CFC
Suspension
HFA HFA
Suspension Solution
Non-Extrafine Extrafine
53. Si no Todo lo Contrario
Ito K, et al. N Engl J Med 2005;352:1967-76.
54. Principio de la Confusión
ÍNDICE
1) Principio de la Confusión
2) No Parece tan Difícil
3) Nuevas Tecnologías
4) También Asma Sistémica y ¿Qué hay de los
Gemelos?
5) Si no todo lo contrario
6) Conclusiones
FOSTER, ha sido formulado con un tamaño de partículas específico (expresado como MMAD) de 0.8 m. La elección precisa de esta MMDA tiene el objetivo de obtener una medicación inhalada con un perfil de DISTRIBUCIÓN PULMONAR óptimo. Con respecto a este punto hay diversas evidencias que dan soporte a la afirmación del excelente perfil de la formulación. Entre ellas destacamos el estudio llevado a cabo por Mariotti y colaboradores en el que los datos de escintigrafía muestran que el depósito pulmonar es comparable entre tres grupos diferentes: Voluntarios sanos - Pacientes EPOC Pacientes asmáticos Disponer de un sistema de liberación que no se afecte por las condiciones del paciente es de extrema importancia en el tratamiento de las enfermedades respiratorias. De hecho, muchos pacientes, particularmente aquellos con EPOC, pueden tener una escasa capacidad inspiratoria que afectaría a la eficacia del dispositivo seleccionado.
La tecnología Modulite ha sido desarrollada por CHIESI con el objetivo de resolver diversos problemas con la sustitución del propelente CFC por HFA. La ventaja clave de esta tecnología es la obtención de formulaciones basadas en HFA, estables y uniformes en su dosis, con flexibilidad y liberación de partículas con una distribución en tamaño de acuerdo al lugar de acción. La tecnología Modulite consigue sus objetivos mediante dos variables: la adición de componentes no volátiles a la formulación y la geometría del orificio del actuador.