El proyecto “ITC SE Lambayeque Norte 220 kV con seccionamiento de la LT 220 kV
Calculo resistencia volteo presa
1. PROYECTO
PRESA MUÑA MAYU
CALCULO DE LA RESISTENCIA CONTRA EL VOLTEO
ALTERNATIVA CUERPO ALTURA BASE AREA PESO EMPUJE BRAZO MOMENTO DE MOMENTO
(H/n) (m) (m) (m2) (kg) (kg) (m) VUELCO RESISTENTE
Y X (kg-m) (kg-m)
Nº 1 C1 9.00 4.80 21.60 51,840.00 3.20 165,888.00
n = 1.875 C2 9.00 2.00 18.00 43,200.00 5.80 250,560.00
B4 = 4.80 C3 1.00 4.80 4.80 11,520.00 2.40 27,648.00
C4 1.00 2.00 2.00 4,800.00 5.80 27,840.00
C5 1.10 2.00 2.20 5,280.00 5.80 30,624.00
A1 10.00 10.00 50.00 50,000.00 3.33 166,666.67
F.Sub= 1.00 S1 10.00 4.14 20.70 13,560.84 3.33 45,202.80
S2 10.00 6.80 34.00 34,000.00 4.53 154,133.33
F.Sub= 1.00 Sismo Presa 5,832.00 4.31 25,135.92
Sismo Agua 365.00 4.00 1,460.00
392,598.72 502,560.00
F.S. = 1.28
CALCULO EN EL TERCIO CENTRAL
Carga actuante en la base de la estructura N = 82,640.00 kg/m
Centroide de aplicación de la carga e = 1.331 m
6.800
2.267
No pasa por el tercio central
CALCULO DE PRESIONES EN LA BASE
Presión Media = 12,152.94 kg/m2 = 1.215 kg/cm2
σ mom = M/S = 22,190.49 kg/m2 = 2.219 kg/cm2
Donde M = momento respecto al eje ==> M= 171,014.72 kg-m/m
2. S = módulo resistente de la sección = 7.71 m2
Presión Máxima = 26,421.27 kg/m2 Presión izquierda(P1) 2.642 kg/cm2
Presión Derecha(P2) (0.212) kg/cm2
-0.212
2.64
RESISTENCIA AL DESLIZAMIENTO HORIZONTAL
C = 42.000 Considerando f'c = 210 kg/cm2
Sumatoria de cargas verticales = 82,640.00 kg/m
= 0.649407593
Fuerza de empuje para el deslizamiento T = 63,560.84 kg/m
Fuerza resistente al deslizamiento Fr = 53,667.04 kg/m
Factor de seguridad al deslizamiento Fs = 0.85